首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 187 毫秒
1.
目的:评估超短TR/TE的SE序列在腹部MRI中的应用价值。材料与方法:通过对其中100例正常和90例腹部病变分别作常规SE和超短TR/TE的SE序列扫描,并对两种图像进行比较。比较项目有:伪影,扫描时间,组织信号,组织及病变的解剖分辨力等。结果:表明超短TP/TE的SE序列比常规SE有伪影少,扫描时间短,组织信号强,组织及病变的解剖分辨力好等优点。结论:超短SE序列在腹部MRI中明显优于常规SE  相似文献   

2.
目的探讨碘油在磁共振上信号特点。方法收集2例肝癌插管化疗栓塞(TACE)患者,于0.5T的MR仪行常规腹部磁共振检查,包括SE序列T1WI、T2WI。制备样品:碘油样品取作肝栓塞剂的碘化油,并各取12ml的蒸馏水、泛影葡胺、碘海醇、碘(分析纯)、大豆色拉油、菜子油、血清置试管内作为对照。将试管顺序排列,于0.5T的MR仪进行多参数扫描;同时,将各制备品试管置于随机选取的常规扫描者体侧,获得试管与身体组织共同扫描图象,计算SNR值进行对比。结果在不同的磁场强度中碘油产生的信号强度不同,但可以通过调整扫描参数使信号强度趋于一致。碘油在体外SE序列T1WI上呈高信号,T2WI上低信号。体内成像的表现与周围环境的信号对比有关,在与正常肝脏对比中均为低信号。碘在MRI各个序列上均不成像,并且影响其他物质的碘油的信号强度低于油脂的信号强度。自旋回波长TR多回波的图像上信号强度SNR,TE30=6.3、TE60=2.8,TE90=1.6。结论可以用在自旋回波长TR多回波的图像来区分碘油,判断碘油的沉积情况,同时显示残存肿瘤的信号。  相似文献   

3.
目的:探讨膝关节周围隐匿性骨折MRI诊断的临床价值.方法:对30例有明确外伤史,临床症状明显但平片检查阴性患者行MRI检查,其中男19例,女11例.使用Philips Intera Achieva超导高场MRI系统,场强1.5 T.采用常规SE序列T1WI成像(TR、TE=700、20)、快速SE序列T2WI成像(TR、TE=4 700/100)和脂肪抑制序列.结果:30例患者共有40处骨髓信号异常,30处为T1WI低信号、T2WI高信号,10处为T1WI低信号、T2WI混杂信号.脂肪抑制序列均为明显高或混杂偏高信号.结论:MRI是早期诊断隐匿性骨折的理想方法,T2WI脂肪抑制序列最为准确和敏感.  相似文献   

4.
磁共振成像技术应用于颞下颌关节紊乱病的评价   总被引:2,自引:0,他引:2  
目的:通过各种MRI扫描序列比较,选择颞下颌关节紊乱病(temporomandibular disorder,TMD)的最佳检查方法。方法:对13例患采用PHILIPS公司的Gyroscan Intera型超导磁共振成像系统。磁场强度1.5T,选择11cm双侧表面线圈,9例采用双侧对比成像,4例单侧成像,共22例,扫描闭口矢状位的自旋回波(SE)T1WI,快速自旋回波(FSE)T2WI,质子密度(PDW)及各种快速梯度回波(Fast Field Echo,FFE)T1W和T2W序列;冠状位扫描T1W和张口矢状位T1W。结果:各种扫描序列均可以显示颞下颌关节(TMJ)的基本解剖结构,从对比度、空间分辨率、信噪比和扫描时间几方面评价,FFE序列在缩短扫描时间的同时保持了一定的信噪比,优于常规SE序列,3D/FFE序列分辨率高,对关节盘、软骨显示好,并能在任意方向多平面重建,可进行精确的体积测量,结论:FFE序列优于常规SE序列,3D/FFE序列更适合于TMJ的检查。  相似文献   

5.
目的探讨低场磁共振快速成像(FLASH)技术在肺癌检查中的成像质量及临床应用价值。方法 68例肺癌患者分别行磁共振成像常规SE序列T1WI成像及快速成像序列T1WI成像。分析成像的伪影,肺癌形态、大小及邻近组织结构的关系,淋巴结肿大情况,病变的信号特点。结果 FLASH序列T1WI成像呼吸伪影低于常规SE序列T1WI成像,血管搏动伪影两者差异无统计学意义。FLASH序列成像轴位、冠状位及矢状位均可清晰显示病变大小、形态及邻近组织结构关系。结论磁共振FLASH成像技术的时间短、无伪影,可作为肺癌检查首选的快速成像序列。  相似文献   

6.
目的分析椎管内肿瘤的MRI表现,对肿瘤进行定位、定性诊断。方法本组54例均经手术与病理证实,病变位于颈段12例,胸段19例,腰骶段23例。用美国GE公司生产的MAX 0.5T超导型扫描机进行扫描。采用自旋回波(SE)序列,T1WI:TR/TE500ms/20ms,T2WI:TR/TE2400ms/100ms。常规扫描冠状位、矢状位、轴位。全部病例均先平扫,其中49例又行强化扫描。观察肿瘤的部位、形态、边界、信号特征、强化表现及与周围结构的关系。结果髓内肿瘤11例,其中星形细胞瘤6例,室管膜瘤4例,血管母细胞瘤1例。髓外硬膜下肿瘤21例,其中神经源性肿瘤13例,脊膜瘤8例。硬膜外肿瘤22例,其中神经鞘瘤9例,转移瘤8例,脂肪瘤5例。结论椎管内肿瘤各自有一定的特征,大部分肿瘤能做出定性诊断,MRI是椎管内肿瘤的首选检查方法。  相似文献   

7.
目的探讨MRI在诊断脑损害后锥体束Wallerian变性中的应用。方法对22例脑损害后锥体束Walle-rian变性患者均行MRI检查。常规行快自旋回波序列(FSE)横断位T1WI(TR 2 286ms,TE 19.6ms)、T2WI(TR4 300ms,TE 113ms)和T2Flair序列(TR 8 502ms,TE 133ms)。视野(FOV)24cm,矩阵320×256,激发次数(NEX)1~2,层厚6mm,层间距1mm,层数21层。22例患者均加扫横轴位DWI(b值为1 000s.mm-2),其中10例另加扫3D-TOF-MRA(TR 26ms,TE 6.8ms)检查。结果 22例患者中,12例患者在脑损害≥4周~≤12个月后行常规MRI检查,主要表现为病变同侧的锥体束呈长T1、长T2信号并同侧大脑脚及桥脑体积稍萎缩;2例患者在脑损害<4周行常规MRI检查,主要表现为病变侧锥体束稍长T1、长T2信号;8例患者在脑损害>1年行常规MRI检查,主要表现为原发病灶、大脑脚及桥脑萎缩并T2Flair像呈现散在斑片稍高信号影。结论 MRI可明确显示脑损害后锥体束Wallerian变性,有助于临床医师对患者运动功能康复的治疗。  相似文献   

8.
本文对29例垂体瘤进行MRI评价,并结合CT进行比较,以提高MRI诊断垂体瘤的准确性。一、资料与方法扫描方法用RARE(rapid acquisition relaxation enhanced)及SE(spin echo)序列,长TR(TR≥1500ms)、长TE(TE≥66ms),以获得T_2加权图像;短TR(TR≤600ms)、短TE(TE≤33ms),以获得T_1加权图像;长TR  相似文献   

9.
目的:比较ACS(AI-assisted Compressed Sensing)序列和BLADE序列在上腹部T2WI的应用价值。方法:对61例磁共振上腹部检查患者分别行BLADE-T2-FSE序列和ACS-T2-FSE序列扫描。由两位医师分别对两组图像中呼吸运动伪影、卷褶伪影、胃肠道蠕动伪影、图像错层情况、胆管和病灶显示清晰度、整体图像质量进行评分;测量并计算两组序列中病灶与肝实质信号强度对比率(Contrast Ratio,CR),并进行统计学分析。结果:ACS序列检查时间10秒,而BLADE序列62秒左右。61例患者共检出75例病灶,其中肝细胞肝癌36例,胆管细胞癌6例,肝血管瘤16例,肝囊肿17例。ACS-T2-FSE序列中各类病灶与肝实质信号的CR均高于BLADE-T2-FSE序列(P均<0.05);两位医师对图像评分一致性良好,ACS-T2-FSE序列中呼吸运动伪影、卷褶伪影、图像错层情况、胆管和病灶显示清晰度与整体图像质量评分均高于BLADE-T2-FSE序列(P均<0.05);胃肠道蠕动伪影评分ACS-T2-FSE序列较BLADE-T2-FSE序列略低,但不具有统计学意义(P=0.128)。结论:与常规BLADE-T2-FSE序列相比,ACS技术大幅缩短扫描时间,减少了呼吸运动伪影和图像错层,提高了图像诊断质量,值得推广。  相似文献   

10.
MRI成像对软组织具有极高的分辨力,可以显示关节各解剖细节及无骨伪影,同时MRI可进行多种参数和多种序列成像,为疾病检测和定性提供了丰富的信息,而且MRI信号的差异基本反映了病变的组织学特点,多方位成像使其在准确地显示病变范围方面具有无可替代的作用[1].为此MRI成像技术在膝关节疾病检查中也得到广泛应用.作者在1998年3月~2001年12月对168例膝关节病人的序列选择,扫描方法及拍摄技术进行探讨,现报告如下.  相似文献   

11.
目的:探讨胃肠道多层螺旋CT水造影方法。方法:30例疑为腹部疾病的患者行胃肠道CT水造影检查,并与内镜检查和(或)手术病理结果比较。扫描前口服等渗甘露醇溶液1800mL,并进行低张处理。结果:30例胃肠道多层螺旋CT水造影病例均获得较为满意的图像,图像无运动伪影,胃肠道内液体密度与周围组织密度对比良好,结构清晰。口服等渗甘露醇溶液(5.07%)使胃肠道各段充盈扩张良好。手术病理结果与胃肠道CT水造影表现相符。结论:多层螺旋CT胃肠道水造影是简便有效、经济实惠、多维的胃肠道造影方法,尤其对胃肠道壁和腔外病变的诊断有较高的临床价值。  相似文献   

12.
MRI具有无辐射、软组织分辨率高、多参数、多序列成像的优势,广泛应用于全身各系统。以往由于肺内氢质子含量低、呼吸运动伪影以及磁化率伪影等原因,MRI被认为不能用于肺部扫描。随着MRI技术的飞速发展,如并行采集技术、呼吸门控技术、新序列的研发以及人工智能的发展,肺部MRI成像逐渐完善。随着人们对辐射剂量和肺结节关注度的增加,肺部MRI的临床需求也逐渐增加。本文将从MRI新技术在结节检出和良恶性鉴别两方面展开综述,包括放射状容积内插式屏气序列、超短回波时间、零回波时间、压缩感知容积内插式屏气序列、纵向弛豫时间定量成像和化学交换饱和转移等MRI新技术。  相似文献   

13.
This paper presents an in-vivo study of synthetic transmit aperture (STA) imaging in comparison with conventional imaging, evaluating whether STA imaging is feasible in-vivo and whether the image quality obtained is comparable with traditional scanned imaging in terms of penetration depth, spatial resolution, contrast resolution and artifacts. Acquisition was performed using our research scanner RASMUS and a 5.5 MHz convex array transducer. STA imaging was acquired using circular wave emulation by 33-element subapertures and a 20 micros linear FM signal as excitation pulse. For conventional imaging, a 64 element aperture was used in transmit and receive with a 1.5 cycle sinusoid excitation pulse. Conventional and STA images were acquired interleaved, ensuring that the exact same anatomical location was scanned. Image sequences were recorded in real time and processed off-line. Seven male volunteers were scanned abdominally and the resulting images were compared by three medical doctors using randomized blinded presentation. Penetration and image quality were scored and evaluated statistically. Results showed slightly but significantly (0.48 cm, p = 0.008) increased penetration using STA. Image quality was also highly significantly (p < 0.001) increased. Results show that in-vivo ultrasound imaging using STA is feasible for abdominal imaging without severe motion artifacts.  相似文献   

14.
目的 探讨IMR迭代算法联合256层iCT低剂量扫描评估慢性鼻窦炎的可行性。 方法 对20例临床拟诊断为慢性鼻窦炎的患者先后分别行标准剂量和低剂量鼻窦CT检查。根据Dose Right指数和重建算法的不同分为;SD-FBP组、LD-IMR-L1组、LD-IMR-L2组及LD-IMR-L3组。记录不同扫描方案下CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP)并计算有效剂量(ED),测量图像的客观噪声值,对图像噪声、伪影、窦口鼻道复合体解剖结构及病变显示情况进行评估并进行统计学分析。 结果 四组图像的平均噪声值从小到大依次为:SD-FBP组、LD-IMR-L3组、LD-IMR-L2组、LD-IMR-L1组。LD-IMR-L3组与SD-FBP组相比,差异无统计学意义。LD-IMR-L2组、LD-IMR-L1组与SD-FBP组相比,差异有统计学意义。LD-IMR各组在伪影及病变的显示上的评分较SD-FBP组无明显区别,均满足了诊断需求; LD-IMR各组在解剖结构细节的显示上较SD-FBP组欠清晰,但评分均在3分以上,均能满足诊断的需求。低剂量组CTDIvol、DLP、ED较常规剂量组分别减少89.20%、89.37%和89.36%。 结论 IMR迭代重建低剂量鼻窦CT在有效降低辐射剂量的条件下,可满足窦口鼻道复合体解剖结构的显示及慢性鼻窦炎的诊断需求。  相似文献   

15.
BLADE刀锋技术详解   总被引:2,自引:0,他引:2  
翁得河 《磁共振成像》2010,1(5):376-379
磁共振成像中,病人运动会产生相位编码方向明显的伪影。伪影主要因为两次激发之间,组织由于运动导致所处空间位置不同所致。关于运动伪影减轻或者消除方法,目前流行的有一维、二维导航回波等。本文主要介绍一种结合快速自旋回波(TSE)和辐射采集的自导航序列:刀锋序列,又称为螺旋桨序列(PROPELLER)。文章重点介绍其数据采集方式,运动纠正方法以及图像重建方法,最后讨论其扫描时间和优缺点。  相似文献   

16.
Ultrasound in vivo imaging using synthetic aperture sequential beamformation (SASB) is compared with conventional imaging in a double blinded study using side-by-side comparisons. The objective is to evaluate if the image quality in terms of penetration depth, spatial resolution, contrast and unwanted artifacts is comparable to conventional imaging. In vivo data was acquired using a ProFocus ultrasound scanner (BK Medical, Herlev, Denmark) and a 192-element 3.5 MHz convex array transducer (Sound Technology Inc., PA, USA). Data were acquired interleaved, ensuring that the exact same anatomical locations were scanned. Eighteen volunteers were scanned abdominally resulting in 85 image sequence pairs. Evaluation of image quality was performed by five medical doctors. Results show that image quality using SASB was significantly better than conventional imaging (p value: <0.01). There was not a significant difference in penetration depth (p value: 0.55). The study supports that in vivo ultrasound imaging using SASB is feasible for abdominal imaging.  相似文献   

17.
目的 探讨3D自由呼吸径向采集K空间放射填充容积内插成像(Star VIBE)序列在儿童腹部MR增强检查中的应用价值。方法 对72例患儿采用超快速小角度激发(tfl)梯度回波序列及3D自由呼吸Star VIBE序列进行腹部增强MR扫描,对2种扫描序列得到的增强T1WI进行主观评分,并测量其SNR和CNR,比较2种图像的差异。结果 3D自由呼吸Star VIBE序列图像呼吸运动伪影、肝内血管和下腔静脉结构显示、胃肠道蠕动伪影、病灶清晰度和整体图像质量评分均高于tfl序列(P均<0.001)。3D自由呼吸Star VIBE序列的SNR为25.14(20.42,30.50),CNR为9.20(7.36,10.42),tfl序列的SNR为20.67(19.00,23.50),CNR为6.08(3.00,8.50);3D自由呼吸Star VIBE序列的SNR、CNR均高于tfl序列(P均<0.001)。结论 3D自由呼吸Star VIBE序列可明显减少儿童腹部增强MRI运动伪影,增加SNR和CNR,对于诊断儿童腹部病变具有重要临床应用价值。  相似文献   

18.
目的探讨KARL-3D迭代重建及去金属伪影(MAC)重建技术在CT检查中去金属植入物伪影的临床应用价值。方法收集105例体内有金属植入物患者的CT扫描数据,对扫描图像进行FBP常规重建、KARL-3D迭代重建及MAC重建。以金属伪影影响最严重的区域作为感兴趣区(ROI),比较三组ROI的CT值、噪声值(SD)、信噪比(SNR)、对比噪声比(CNR)和主观评分。结果三组图像的CT值、SD、SNR、CNR和主观评分比较,差异均具有统计学意义(P<0.05),其中SD值(SD1与SD2)的排序为FBP组>KARL-3D迭代组>MAC组;余三项指标(SNR1,SNR2和CNR)排序均为FBP组相似文献   

19.
目的:探究增强CT放射对出现腹腔转移的腹部肿瘤的诊断作用。方法:将2017年10月~2019年10月在我院放射科接受检查的54例患有腹部肿瘤并出现腹腔转移的患者作为研究对象,按照检测方式差异将其分为CT组及增强CT组,所有患者均依次接受常规CT及增强CT扫描诊断,对两组患者临床诊断检查相关资料进行回顾性分析。结果:增强CT诊断患者腹部肿瘤的准确率(90.74%)明显高于常规CT诊断(72.22%),两组差异对比具有统计学意义(P<0.05)。增强CT诊断出患者肿瘤腹腔转移的准确性(94.44%)明显高于CT诊断(72.22%),两组差异对比具有统计学意义(P<0.05)。增强CT检出患者种植灶长、种植灶宽及最小种植灶面积均小于CT检测,两组差异对比具有统计学意义(P<0.05)。结论:增强CT诊断腹部肿瘤患者肿瘤的腹腔内转移具有良好的效果,能够良好判断患者肿瘤病灶情况及转移状况,能检出较小的肿瘤组织,具有较高的临床应用价值。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号