1.
Bond strength of luting cements to zirconium oxide ceramics   总被引:7,自引:0,他引:7  
PURPOSE: This study was conducted to determine the bond strength of some resin luting cements to zirconia ceramic. The hypothesis was that adhesive bonding capacity is influenced by different surface pretreatments designed for milled ceramic inlays. MATERIALS AND METHODS: Composite cylinders 5 mm x 5 mm were light cured on the ceramic surfaces for a shear test conducted in a test jig. Five surface treatments were studied: as received (from the milling machine), sandblasting with either 250- or 50-micron alumina sand, hydrofluoric acid treatment, and grinding with diamond burs. The tested luting cements were Panavia 21, Twinlook, and Superbond C&B. RESULTS: All debonding occurred at the interface between ceramic and composite cement. Superbond demonstrated the highest bond strength regardless of the surface treatments. Grinding the surface with diamond burs improved the bonding slightly for Twinlook and Panavia 21 and also showed the roughest texture. Washing with hydrofluoric acid had no significant influence on bond strength. CONCLUSION: Bond strengths for Twinlook and Pananvia 21 were quite low, and only Superbond showed a bond strength reasonably acceptable for clinical use; however, as no standard for bond strength has been established for inlay therapy, the other cements cannot be rejected as luting cements for inlays.  相似文献   

2.
PURPOSE: This study evaluated the effect of thermocycling on the microtensile bond strength of four adhesive luting agents to GN-I CAD-CAM ceramic. The hypothesis tested was that thermocycling did not affect bonding effectiveness, irrespective of the luting agents used. MATERIALS AND METHODS: Ceramic specimens of two different sizes (6x8x3 mm; 13x8x4 nm) were fabricated from GN-I CAD-CAM ceramic blocks (GC) using a low-speed diamond saw. Two different sized porcelain discs were bonded with one of the four composite luting agents (Linkmax [LM], Panavia [PN], RelyX Unicem [UN] and Variolink II [VL]) according to the manufacturer's instructions. The specimens were stored for 24 hours in distilled water at 37 degrees C and subjected to 0; 10,000; 20,000 and 40,000 thermocycles prior to microTBS testing. Two-way analysis of variance was used to test the influence of luting cement, thermocycling and interaction between both (p < 0.05). The Tukey HSD test determined statistical differences in microTBS for each luting composite between the different thermocycling conditions (p < 0.05). The mode of failure was determined at a magnification of 50x using a stereomicroscope (Wild M5A). RESULTS: Two-way ANOVA revealed that microtensile bond strength was affected by the luting cement, thermocycling and a combination of both. No difference in bond strength between Linkmax, Panavia F and Variolink II was noticed after 24 hours of water storage (LM: 47.6 MPa; PN: 41 MPa; VL: 36 MPa). RelyX Unicem scored significantly lower than Linkmax and Panavia F (UN: 24.2 MPa). The influence of thermocycling on bond strength was different for the four luting cements. Using Variolink II, the bond strength remained stable after 40,000 thermocycles (43.6 MPa). Linkmax showed a significant decrease in bond strength after 10,000 (26 MPa) and 40,000 thermocycles (14.8 MPa). Panavia F and RelyX Unicem were the most negatively influenced, as all specimens failed prior to testing (pre-testing failures) when the specimens were thermocycled 10,000 and 20,000 times or longer, respectively. Regarding the failure mode, there was a correlation between bond strength and type of failure. Initially, a combination of adhesive and mixed adhesive-cohesive failures was noticed. The percentage of adhesive failures increased, together with a decrease in bond strength. CONCLUSION: It was concluded that there were significant differences among the four resin composite cements in terms of their bonding effectiveness to CAD-CAM ceramic after thermocycling. The varying degrees of bonding effectiveness of these adhesive luting agents highlight the need for material specifications.  相似文献   

3.
PURPOSE: To compare the push-out bond strengths of endodontic posts bonded with different resin-based luting cements and to verify that bond strengths did not vary with cement thickness. METHODS: 48 root canals were shaped using 6% NiTi rotary files, obturated with gutta-percha and AH Plus sealer and prepared for post cementation using Panavia F, Parapost cement, SuperBond and Unicem Rely X. All roots were sectioned into 0.7 mm thick slices and digital photographs of each slice were analyzed using Scion Image to measure the surface area of the luting cement. The root slices were stressed to failure at 1 mm/minute using a push-out test. Push-out strength was calculated as the force at failure divided by the bonded surface area. Least squares linear regression analysis was used to assess the effect of cement thickness on bond strength. Fractured specimens were further observed under the SEM. RESULTS: Mean push-out bond strengths were: Panavia F (8.8 +/- 3.6 MPa), Parapost cement (9.1 +/- 4.4 MPa) SuperBond (14.6 +/- 2.9 MPa) and Rely X Unicem (12.4 +/- 3.3 MPa). The Panavia F and the Parapost cement were not significantly different from each other, but both were significantly lower (P < or = 0.05) than SuperBond and Rely X Unicem. Although there were large variations in cement thickness, the cementation of fiber posts with thicker cement layers did not affect the performance of the adhesive luting cements applied to root canal dentin.  相似文献   

4.
The purpose of this study was to evaluate the effect of different adhesive cements and thermocycling on the fracture resistance of IPS e.max Press posterior single crowns. Thirty-two sound maxillary molars were subjected to standardized preparation and received IPS e.max Press crowns. Another 16 molars were left unprepared to serve as controls (group 1). Panavia F 2.0 and Rely X Unicem luting cements were used to bond the fabricated crowns (n = 16 each) to their respective prepared teeth. Eight specimens from each of the three groups were selected randomly for further thermocycling (5,000 cycles). All specimens were then subjected to fracture resistance testing using anatomical metal attachments fixed to the upper portion of the universal testing machine (1 mm/min). Data were analyzed statistically using two-way analysis of variance and the Student t test (α = .05). Natural teeth presented significantly higher (1,043 and 1,279 N) fracture resistance than that of adhesively cemented ceramic crowns (907 to 986 N) before and after thermocyling, respectively (P < .05). Cement type did not significantly affect fracture resistance results (986 N and 974 N for Panavia F 2.0 and Rely X Unicem, respectively; P > .05). Thermocycled specimens showed lower fracture resistance than that of nonthermocycled ones (P < .05). Neither conventional adhesive cement nor self-etching adhesive cement affected the fracture resistance of IPS e.max crowns. Thermocycling decreased the fracture strength of the crowns in both cement groups. Natural teeth fractured at significantly higher loads than the ceramic crowns.  相似文献   

5.
OBJECTIVE: This study evaluated the shear bond strength of two resin composite luting cements to zirconium oxide ceramic substrate using two air-particle abrasion methods. METHODS: Two resin composite cements, RelyX Unicem (3M ESPE) and Panavia F (Kuraray), each with an acidic composition, were used in combination with a zirconium oxide (DCS Dental AG) substrate containing Al2O3 and SiO2 (Rocatec system, 3M ESPE) and two air-particle abrasion methods. The shear bond strength of the resin composite cement to the substrate was tested after the samples were either water-stored for one week or thermocycled following 24 hours of water storage. RESULTS: The RelyX Unicem resin composite cement specimens with the Rocatec treatment (20.9 +/- 4.6 Mpa and 20.1 +/- 4.2 MPa, respectively, n = 12) demonstrated the highest shear bond strength. Alternatively, the lowest values were obtained for the Panavia F resin cement samples, with Al2O3 air-particle abrasion in both storage conditions, water storage for one week (17.7 +/- 8.9MPa) or thermocycling after 24 hours of water storage (16.3 +/- 4.9 MPa). Neither storage condition or particle abrasion system significantly affected shear bond strengths (ANOVA, p > 0.05). CONCLUSION: It was concluded that two different surface conditioning methods and storage conditions did not significantly affect the bonding properties of Panavia F and RelyX Unicem resin composite luting cements to Zirconia.  相似文献   

6.
STATEMENT OF PROBLEM: In contrast to gold crowns, in vitro determination of the retentive strength of all-ceramic crowns is more difficult because components allowing connection to testing apparatus are not as easily integrated into the all-ceramic material. Nevertheless, retentive strength data are crucial for obtaining information about the potential clinical performance of luting cements for all-ceramic restorations. Therefore, a new in vitro model was necessary to evaluate the retentive strength of all-ceramic crowns. PURPOSE: The purpose of this in vitro study was to determine the retentive strength of 4 resin-cement systems, a compomer, a glass-ionomer cement, a resin-modified glass-ionomer cement, and a self-adhesive resin for luting zirconium oxide ceramic crowns. MATERIAL AND METHODS: One-hundred-twenty extracted human teeth were randomly divided into 12 groups (n = 10) and prepared in a standardized manner (5-degree taper, 3-mm occlusogingival height). All-ceramic crowns (Lava) were fabricated in a standardized manner for each tooth. The following cements and corresponding bonding regimens were used to lute the crowns to the teeth according to manufacturers' recommendations: CO, Compolute/EBS Multi; CO/RT, Compolute/EBS Multi/Rocatec; CB, Superbond C and B; CB/RT, Superbond C and B/Rocatec; CB/PL, Superbond C&B/Porcelain Liner M; PA, Panavia F; DC, Dyract Cem Plus/Xeno III; CH/PL, Chemiace II/Porcelain Liner M; RL, RelyX Luting, K/C, Ketac Cem/Ketac Conditioner; K, Ketac Cem; and RU, RelyX Unicem. After thermal cycling (5000 cycles, 5 degrees C-55 degrees C), the outer surfaces of the cemented zirconium oxide ceramic crowns were treated (Rocatec) to improve bonding and then placed into a low-shrinkage epoxy resin block (Paladur). The block/crown and tooth components for each specimen were connected to opposing ends of a universal testing machine so that crown retention could be measured. Crowns were removed from teeth along their path of insertion. The retentive surface area (mm 2 ) was determined individually for each tooth. Statistical analyses were performed using the Wilcoxon exact test, (alpha =.05) and a Bonferroni correction (alpha =.001). RESULTS: The median (minimum/maximum) retentive strength values (MPa) were as follows: CO, 1.7 (0.6/4.3); CO/RT, 3.0 (1.3/5.4); CB, 4.8 (3.7/7.9); CB/RT, 8.1 (4.2/12.7); CB/PL, 5.3 (3.7/10.2); PA, 4.0 (3.3/5.1); DC, 3.3 (2.1/5.6); CH/PL, 4.0 (1.3/6.3); RL, 4.7 (2.8/6.6); K/C, 1.8 (0.6/2.3); K, 1.9 (0.2/4.5); and RU, 4.8 (2.5/6.7). Superbond C&B (+ Rocatec) specimens showed the highest median retentive strength, but were not significantly different from Superbond C&B without Rocatec pretreatment of the all-ceramic crown's inner surface. Compolute specimens also did not benefit significantly from the Rocatec pretreatment. Within the materials used without pretreatment of the ceramic, Superbond C&B, Panavia, Dyract Cem Plus, RelyX Luting, and RelyX Unicem showed the highest median retentive strength values and were not significantly different. CONCLUSION: Within the conditions of this study, the compomer-cement, the resin-modified glass-ionomer cement, and the self-adhesive resin luting agent had the same level of retentive quality as the resin luting agents, Superbond C&B, and Panavia. Rocatec pretreatment of the ceramic surface did not improve the retentive strengths of Compolute and Superbond C&B.  相似文献   

7.
王宁  刘晓  骆小平 《口腔医学研究》2011,27(8):706-709,712
目的:研究3种复合树脂粘固剂与铸造纯钛的粘接强度。方法:用牙科铸钛的方法制作直径分别为4mm和5mm的钛棒,切割成长度为4mm的小钛片。2种规格的钛片配对粘接面用400~1200目碳化硅砂纸在流水下打磨抛光,使之呈均匀一致的平面。50μm氧化铝喷砂,另一组表面不喷砂作为对照,分别使用Super-BondC&B、Panavia F、Rely X Unicem 3种复合树脂粘固剂粘接。扫描电镜观察喷砂前后铸造纯钛的表面形态。复合树脂粘接剂固化后经37℃恒温水浴24h以及5000次5~55℃冷热循环,测试剪切强度。用SAS的ANOVA过程对各组数据进行分析。结果:喷砂前后纯钛与Panavia F的剪切强度最高,分别为(26.62±3.40)MPa、(23.71±5.28)MPa;5000次冷热循环后,喷砂组的铸造纯钛与Panavia F的剪切强度最高(27.12±8.68)MPa;未喷砂的铸造纯钛与Super-Bond C&B、Rely X Unicem的粘接强度最低,并且有12.5%的脱落率。结论:本实验结果表明喷砂可以提高Super-Bond C&B、Panavia F、Rely X Unicem的粘结力和粘结耐久力。不喷砂时,Panavia F与铸造纯钛之间能获得较高的粘接强度和良好的粘接耐久性,喷砂以后优势不再明显。  相似文献   

8.
This study evaluated the shear-bond strength of 11 luting cements from different material classes to manufactured pre-treated zirconia ceramics (Lava: 97% ZrO2, stabilized with 3% Y2O3). In addition, the influence of the curing method on shear-bond strength was investigated. The cements examined were one zinc-phosphate cement (Fleck's zinc cement), two standard glass-ionomer cements (Fuji I, Ketac-Cem), three resin-modified glass-ionomer cements (Fuji Plus, Fuji Cem, RelyX Luting), four standard resin cements (RelyX ARC, Panavia F, Variolink II, Compolute) and one self-adhesive universal resin cement (RelyX Unicem). The ceramic surface was sand-blasted with 100-microm alumina or tribochemically coated with silica. After bonding procedure, one group was tested after 30 minutes (Time I), the other group was stored in distilled water at 37 degrees C for 14 days and subsequently thermocycled 1000 times (Time II). Statistical analysis was performed by multifactorial ANOVA models with interactions. For multiple pairwise comparisons, the Tukey method was used. After sandblasting, the highest shear-bond strength was obtained for the self-adhesive universal resin cement at 9.7 MPa (Time I) and 12.7 MPa (Time II), respectively. When using the Rocatec system, the highest values were found for one of the resin cements at 15.0 MPa (Time I) and for the self-adhesive universal resin cement at 19.9 MPa (Time II).  相似文献   

9.
STATEMENT OF PROBLEM: Bonded densely sintered aluminum oxide ceramic restorations such as Procera AllCeram laminates rely on a strong and long-term durable resin bond. Air particle abrasion and a phosphate-modified resin luting agent have the potential to provide such bonds to aluminum oxide ceramics, but their efficacy on the Procera AllCeram intaglio surface is unknown. The inherent microroughness of this surface may influence bond strengths, because micromechanical interlocking is a main contributor for adhesion of resins to ceramic materials. PURPOSE: This study evaluated the bond strength of a phosphate-modified resin luting agent with and without silanization to an air particle-abraded Procera AllCeram intaglio surface compared with a conventional resin-bonding system before and after artificial aging. MATERIAL AND METHODS: Sixty square (10 x 10 x 2 mm) specimens of Procera AllCeram alumina ceramic with the Procera intaglio surface were air particle abraded with aluminum oxide. Composite cylinders (2.9 mm in diameter and 3.0 mm in width) were fabricated with Z-250 composite and bonded to the ceramic specimens with either Panavia 21 TC or Rely X ARC (control) and their corresponding bonding/silane coupling agents. In addition, Panavia was used without silanization as suggested in similar studies. Subgroups of 10 specimens were stored in distilled water for either 3 or 180 days before shear bond strength was tested with a universal testing machine (MPa) until fracture. The 180-day specimens were subjected to thermocycling at 2000 cycles every 30 days (12,000 cycles total). Data were analyzed with 1-way analysis of variance and Tukey's multiple comparison (alpha=.05). Failure modes were examined with a light microscope (original magnification x 25). RESULTS: Differences between short-term and long-term groups were highly significant (P=.000). Bond strength with Rely X ARC and its silane coupling agent (22.75 +/- 4 MPa) decreased significantly (P=.000) after artificial aging (3.32 +/- 3.62 MPa). Panavia 21 after silanization revealed significantly different (P=.003) early (21.42 +/- 4.3 MPa) and late (16.09 +/- 2.37 MPa) bond strengths but achieved the highest bond strength after artificial aging. Bond strengths of Panavia without silanization both early (8.06 +/- 2.1 MPa) and late (6.91 +/- 2.49 MPa) were not significantly different. Failure modes were mainly adhesive at the ceramic surface for all groups. CONCLUSION: Panavia 21 in combination with its corresponding bonding/silane coupling agent can achieve an acceptable resin bond to the air particle-abraded intaglio surface of Procera AllCeram restorations after artificial aging, which had mixed effects on the other investigated groups. The conventional resin luting agent revealed the most dramatic decrease in bond strength.  相似文献   

10.
Very limited comparative information about the microleakage in noble alloy full cast crowns luted with different types of adhesive resin cements is available. The purpose of this study was to evaluate the microleakage and marginal gap of two self-adhesive resin cements with that of other types of adhesive luting cements for noble alloy full cast crowns. Fifty noncarious human premolars and molars were prepared in a standardized manner for full cast crown restorations. Crowns were made from a noble alloy using a standardized technique and randomly cemented with five cementing agents as follows: 1) GC Fuji Plus resin-modified glass ionomer cement, 2) Panavia F 2.0 resin cement, 3) Multilink Sprint self-adhesive resin cement, 4), Rely X Unicem self-adhesive resin cement with pretreatment, and 5) Rely X Unicem with no pretreatment. The specimens were stored in distilled water at 37°C for two weeks and then subjected to thermocycling. They were then placed in a silver nitrate solution, vertically cut in a mesiodistal direction and evaluated for microleakage and marginal gap using a stereomicroscope. Data were analyzed using a nonparametric Kruskal-Wallis test followed by Dunn multiple range test at a p<0.05 level of significance. The Rely X Unicem (with or with no pretreatment) exhibited the smallest degree of microleakage at both tooth-cement and cement-crown interfaces. The greatest amount of microleakage was found for Panavia F 2.0 resin cement followed by GC Fuji Plus at both interfaces. No statistically significant difference in the marginal gap values was found between the cementing agents evaluated (p>0.05). The self-adhesive resin cements provided a much better marginal seal for the noble alloy full cast crowns compared with the resin-modified glass ionomer or dual-cured resin-based cements.  相似文献   

11.
STATEMENT OF PROBLEM: The resistance to fracture of ceramic restorations depends on adequate bonding to tooth structure. The dental substrate and the types of resin luting agents used are believed to produce variability in adhesive properties. PURPOSE: The purpose of this study was to evaluate the tensile bond strength of 4 resin luting agents to bovine enamel and dentin. MATERIAL AND METHODS: Forty bovine incisors were embedded in acrylic resin and ground horizontally with water-cooled silicon carbide paper to expose enamel (20 teeth) and dentin at the enamel/dentin junction (20 teeth). Ten standard cone-shaped specimens with a 3-mm diameter base were prepared for each of the following resin cements: Resin Cement, Rely X ARC, Nexus, and Enforce. Five specimens of each material were bonded to enamel and the other 5 to dentin with these resin luting agents and their respective adhesive systems, according to the manufacturers' directions. After 7 days of storage in distilled water at 37 degrees C, specimens were subjected to tensile forces in a universal testing machine at a crosshead speed of 0.5 mm/min until fracture. Bond strength data were analyzed with analysis of variance for substrate and material. Means were compared with Tukey's test at the 0.05 level of significance. RESULTS: Analysis of variance disclosed that both substrate (P<.001) and material (P<.05) demonstrated statistically significant differences, but their interaction was not significant. The bond strengths (MPa) obtained for Resin Cement (11.5 +/- 3.0), Rely X ARC (11.4 +/- 3.1), Nexus (10.0 +/- 1.4), and Enforce (11.8 +/- 2.8) were statistically the same for enamel. For dentin, bond strengths (MPa) for Rely X ARC (9.6 +/- 1.8), Resin Cement (9.3 +/- 0.9), and Enforce (7.8 +/- 2.9) were significantly higher than for Nexus (3.5 +/- 0.8). Significantly higher bond strengths (MPa) were also observed for enamel (11.2 +/- 2.5) than dentin (7.5 +/- 1.6). CONCLUSION: Within the limitations of this study, tensile bond strengths of resin luting agents to enamel were higher than those to dentin, and the bond strength values of Nexus to dentin were significantly lower (P<.05) than the other cements tested.  相似文献   

12.
目的观察Rely X ABC、Para Cem Universal DC和Rely X Unicem 3种临床常用的树脂黏结剂黏固纤维桩的效果。方法选择2006年6月至2008年6月于中国医科大学口腔医学院修复科采用纤维桩修复并完善根管治疗的42例前牙牙体缺损患者的99颗患牙,随机分为3组,每组33颗,分别用不同的黏结剂(Ⅰ组:Rely X ARC;Ⅱ组:ParaCem Universal DC;Ⅲ组:Rely X Unicem)黏固纤维桩。随访0.5~2年,观察修复效果。结果Rely X ARC、ParaCem Universal DC和Rely X Unicem 3种树脂黏结剂用于黏固纤维桩的成功率依次为93.9%、84.8%、97.0%。结论Rely X ARC和Rely X Unicem黏结剂用于临床黏固纤维桩均表现出良好的临床效果。  相似文献   

13.
Kim MJ  Kim YK  Kim KH  Kwon TY 《Journal of dentistry》2011,39(11):795-803

Objectives

To measure the shear bond strengths of various luting cements to a sandblasted zirconia ceramic and to determine the surface energy parameters of the luting cements.

Methods

Two conventional glass ionomer cements, two resin-modified glass ionomer cements, two compomer cements, and two adhesive resin cements were prepared and bonded to sandblasted zirconia (Lava). All bonded specimens were stored in water at 37 °C for 48 h and then half of them additionally thermocycled 10,000 times prior to the shear bond strength test (n = 10). Surface roughness (Ra) values and surface energy parameters of the eight luting cements and polished zirconia ceramic were evaluated using a profilometer and contact angle measurements, respectively (n = 10). The bond strength and surface roughness data were statistically analysed using non-parametric and parametric procedures, respectively (α = 0.05). Relationships between surface energy parameters and measured shear bond strengths were investigated using the Spearman rank correlation test.

Results

Panavia F 2.0 and Principle produced higher bond strengths than the other cements, with no significant changes before and after thermocycling. Fuji I, Ketac Cem Easymix, and Ionotite F yielded near-zero or zero values after thermocycling. All debonded specimens showed adhesive failure. Mean Ra values ranged from 0.104 to 0.167 μm. We found the base (hydrogen bond accepting) components of the luting cements significantly affected the bond strengths both before and after thermocycling.

Conclusion

It is recommended that the surface energy parameters of luting cements be considered in evaluating their adhesive properties with zirconia ceramic.  相似文献   

14.
目的比较3种不同粘接剂对3种全瓷材料与牙本质之间抗剪切粘接强度的影响。方法样本为热压铸造陶瓷组、氧化铝渗透陶瓷组和氧化锆切削陶瓷组,每组各18片,各组再随机分为A、B、C3个小组,每小组6片。将收集的离体恒磨牙打磨至牙本质浅层,分别采用树脂类粘接剂RelyXTM ARC、PanaviaTMF以及Rely XTM Unicem与3种全瓷片粘接。所有试件均置于37℃人工唾液,24h后测试54个试件的抗剪切强度。结果热压铸造陶瓷组与氧化锆切削陶瓷组均为RelyXTM Unicem抗剪切粘接强度最高,而氧化铝渗透陶瓷组PanaviaTM F抗剪切粘接强度最高。结论对于3种不同全瓷材料,临床上可根据全瓷修复体的种类选择适当的粘接剂系统。  相似文献   

15.
目的:比较2种不同贴面材料与3种不同的瓷贴面粘接系统粘接后的粘接强度。方法:应用3种不同的瓷贴面粘接系统(Panavia F、Variolink Veneer、RelyX Veneer),将经过相同处理的离体牙和2种不同的贴面材料(IPS e.max铸瓷和CERAM-AGE聚合瓷)粘接,每组中随机选取一半试件(n=8)37℃水浴24 h,另一半(n=8)冷热循环5 000次后测试其剪切强度,电镜下观察断裂模式。结果:IPS e.max铸瓷组和CERAMAGE聚合瓷组中Variolink Veneer粘接系统在37℃水浴24 h后或5 000次冷热循环后都表现出了最高的粘接强度(P<0.05),所有试件在经过5 000次冷热循环后的粘接强度除Panavia F组外都有明显下降。结论:对于IPS e.max铸瓷和CERAMAGE聚合瓷,Variolink Veneer粘接系统的粘接强度高于Panavia F和RelyXVeneer粘接系统。  相似文献   

16.
OBJECTIVES: The aim of this study was to evaluate the tensile bond strength of dual curing luting resin cements to commercially pure titanium at 10 min and 24h after removal of the oxide layer. METHODS: One hundred and twenty titanium discs were obtained by casting and polishing with silicon carbide papers. The titanium discs were sandblasted with 50 microm aluminum oxide, ultrasonic cleaned and bonded in pairs with the resin-based cements Panavia F and Rely X ARC at 10 min and 24h after the sandblasting. The tensile test was performed with a crosshead speed of 0.5mm/min in an Instron Universal testing machine. RESULTS: The Rely X ARC reached the highest tensile strength value at 24h after sandblasting (18.27 MPa), but there was no statistically significant difference between the two dual curing resin cements for both times tested. All specimens showed a mixture of cohesive fracture in the resin cement and adhesive failure. However, the predominant failure mode for Panavia F was cohesive in resin cement, and the Rely X ARC exhibited a greater proportion of specimens with adhesive failure between the alloy and resin luting cement at 10 min and 24h. SIGNIFICANCE: Both cements had, statistically, the same tensile bond strength. But in the fracture mode analysis, the adhesive predominant fracture mode of Rely X ARC cement indicates a premature clinical adhesive failure. On the other hand, the cohesive predominant fracture mode of Panavia F indicates a longer clinical adhesive bond with titanium.  相似文献   

17.
OBJECTIVES: To investigate the bond strength of modern "self-adhesive" resin cements to a zirconium-based dental ceramic following different surface preparations and storage conditions. METHODS: The surface of zirconium-based ceramic discs (12 x 2 mm) were either left untreated, prepared using alumina grit-blasting or tribochemical treatment. Resin composite cylinders were bonded to ceramic specimens using Panavia-F, RelyX Unicem or Maxcem resin cements. The shear bond strength of specimens (n = 10) was tested "dry," following 24-hour water immersion or a thermocycling regime. RESULTS: For each surface preparation, a significant reduction in bond strength following 24-hour water immersion and thermocycling compared to "dry" storage conditions was identified for both Panavia-F and Maxcem. However, Unicem specimens exhibited statistically similar SBS values for tribochemically-treated specimens stored dry following 24-hour water immersion or thermocycling (11.7 +/- 1.3, 14.1 +/- 6.3 and 11.7 +/- 4.9 MPa, respectively) (p > 0.05). No significant differences in bond strength were identified for Panavia-F or Unicem specimens for any surface preparation following the thermocycling regime (p > 0.05). In contrast, for each surface preparation following thermocycling (p < 0.001), Maxcem exhibited a significant decrease in SBS compared with Panavia-F and Unicem specimens. CONCLUSIONS: The pre-treatment of a zirconium-based ceramic surface with grit-blasting and tribochemical treatment improves the bond strength of resin cements. Following "wet" storage conditions, Panavia-F and Unicem demonstrated superior bond strength compared with Maxcem. Differences in ceramic surface preparation and the chemistry of resin cements will affect the nature of the bonding mechanism and durability of the adhesive layer.  相似文献   

18.
OBJECTIVE: The aim of this study was to find the optimal choice of luting cement to Synthoceram, an aluminum oxide-reinforced glass ceramic material. The bond strength of five different commercial luting cements to the ceramic material was evaluated. The effect of surface treatments, etching, sandblasting, silanizing, and combinations of these treatments was also investigated. METHODS: Shear bond strength tests were performed using the ceramic material as substrate with each of the luting cements. Cements rods were prepared on pre-treated ceramic surfaces. The shear bond strength was determined 24 h after cementation. The effect of surface treatments: etching, sandblasting, and sandblasting followed by etching, respectively, on the morphology of the material, was investigated with SEM. RESULTS: The shear bond strength increases significantly from Ketac Cem, Rely X Luting, Fuji Plus, Panavia F to Xeno Cem. The surface treatments etching and/or sandblasting followed by silanization generally provide the highest bond strength values. SIGNIFICANCE: Based on the results of this study, the use of resin composite based cements is preferred for cementation of an all-ceramic restoration with an aluminum oxide-reinforced glass ceramic base. Surface treatment of etching and/or sandblasting followed by silanization is recommended.  相似文献   

19.
氧化锆陶瓷与三种树脂粘接剂粘接剪切强度比较   总被引:2,自引:0,他引:2  
目的探讨适合牙科氧化锆陶瓷的粘接材料。方法将烧结后的氧化锆陶瓷片分为3组,每组32片,分别采用三种自酸蚀粘接剂RelyX Unicem、PanaviaTM F、Superbond C﹠B与喷砂后的氧化锆陶瓷片粘接,水浴24h和水浴30d后,测试其粘接剪切强度。数据用SAS9.12软件进行统计学分析,粘接断面用扫描电镜观察。结果 PanaviaTMF树脂粘接材料粘接强度最好,分别为(31.36±3.49)MPa(水浴24h)、(29.52±3.44)MPa(水浴30d)。Superbond C﹠B能够取得较好的初期粘接强度(31.85±3.61)MPa(水浴24h),但水浴30d后明显下降至(21.32±2.58)MPa,P〈0.05。RelyX Unicem的初期(水浴24h)粘接强度最小为(13.29±3.05)MPa,P〈0.0001,但水浴30d后粘接强度为(12.06±2.28)MPa,未见明显降低,P(0.05。结论含有MDP磷酸单体的树脂粘接材料可以使牙科氧化锆陶瓷获得最好的粘接效果。使用不含无机填料的化学固化型纯树脂粘接剂可以取得较好的初期粘接强度但长期效果欠佳。一步法自酸蚀树脂粘接剂虽然没有很高的初期粘接强度,但粘接效果尚能持久。  相似文献   

20.
OBJECTIVES: To evaluate the bonding effectiveness of self-adhesive luting cements to dentin in the presence of simulated hydrostatic intrapulpal pressure (PP). METHODS: Thirty composite overlays (Aelite All Purpose Body) were luted to deep-coronal dentin surfaces using four self-adhesive resin cements (Rely X Unicem, G-Cem, Multilink Sprint, Bis-Cem) and one total-etch system (Calibra). Half of the specimens resin cements were applied under a PP of 15 cm H2O. After storage in a moist condition for 1 month (37 degrees C, 100% relative humidity), specimens were sectioned into microtensile beams (1mm2) and stressed to failure with the microtensile bond strength test (microTBS). Data were statistically analyzed with Kruskal-Wallis ranking (p<0.05) and Mann-Whitney tests (p<0.001). The fracture pattern was evaluated under SEM. RESULTS: Bond strength of Calibra fell significantly when PP was applied during bonding (p<0.05). Rely X Unicem and Bis-Cem performed better under PP. No significant differences for Multilink Sprint and G-Cem bonded specimens were recorded with or without PP. SIGNIFICANCE: Simulated PP influences the adhesive performance of resinous cements. The predominance of acid-base reactions or radical polymerization may explain the different behavior of self-adhesive cements when changing substrate wetness. The application of constant intrapulpal perfusion should be considered when simulating luting procedures in vitro.  相似文献   