1.

Objective

We wanted to validate the additional merit of the thinner coronal reformation images from multidetector CT (MDCT) for making the diagnosis of hepatic cysts.

Materials and Methods

For the 90 benign hepatic cysts confirmed on MRI, the transverse (5-mm thickness) and additional coronal (2-mm thickness) reformation images from MDCT were compared with each other in terms of the Hounsfield units (HUs) and the size of each hepatic cyst.

Results

The attenuations (mean: 17.2 HUs, standard deviation: ± 14.4) on the thinner coronal images were significantly lower than those (mean: 40.7 HUs; standard deviation: ± 20.6) on the thicker transverse images for the small hepatic cysts (≤ 10 mm on the transverse image, p < 0.01). Twenty-three (79%) of the 29 cysts between 5 mm and 10 mm and 21 (51%) of 41 lesions up to 5 mm showed a mean HU value of 20 or less on the coronal reformation images.

Conclusion

By reducing the partial volume effect, routine coronal reformation of MDCT with a thinner section thickness can provide another merit for making a confidential diagnosis of many small sub-centimeter hepatic cysts, and these small cysts are not easily characterized on the conventional transverse images.  相似文献   

2.
PURPOSE: To evaluate image quality of coronal reformations of chest performed on 64-row MDCT in comparison with 16-, 8- and 4-row MDCT. MATERIALS AND METHODS: Consecutive patients who underwent pulmonary CT angiography using four different MDCT scanners were retrospectively studied with IRB approval: (1) n=30, 64-row MDCT; (2) n=30, 16-row MDCT; (3) n=30, 8-row MDCT; (4) n=30, 4-row MDCT. Coronal reformatted images (2 mm thickness and 2mm intervals for 64-row MDCT; 5 mm thickness and 5 mm intervals for 16-, 8- and 4-row MDCT) were evaluated by consensus reading of two board-certified radiologists who were blinded to scanner type. The image quality of overall chest appearance and individual thoracic structures including heart, aorta and pulmonary arteries was graded using five-point scale. Grades from four different scanners were compared using Kruskal-Wallis test. A second evaluation was performed in 48 randomly selected patients (12 patients for each scanner). Reproducibility was assessed using weighted-kappa analysis. RESULT: Significant reproducibility was observed between the first and second evaluations in 48 patients both for image quality of overall chest (weighted kappa=0.826) and each thoracic structure (mean weighted kappa=0.803; range, 0.729-0.858). Image quality of overall chest and individual thoracic structures differed significantly among four different MDCT groups, with 64-row MDCT having the highest grades, followed by 16-, 8- and 4-row MDCT (mean grades for overall chest in each scanner: 3.9, 3.0, 2.4 and 1.9, respectively) (P<0.0001 for overall chest and each thoracic structure). CONCLUSION: When comparing coronal reformations of chest using four different MDCT scanners, the 64-row MDCT had the highest image quality for overall chest appearance and individual thoracic structures, followed by 16-, 8- and finally 4-row MDCT.  相似文献   

3.
64 Slice multi-detector row cardiac CT   总被引:1,自引:0,他引:1  
Cardiac imaging is feasible with multi-detector row (MDCT) scanners. Coronary arterial anatomy and both non-calcified and calcified plaques are depicted at CT coronary angiography. Vessel wall pathology and luminal diameter are depicted, and secondary myocardial changes may also be seen. Diagnostic capacity has increased with technological advancement, and preliminary investigations confirm the utility of 64-MDCT in low- and intermediate-risk patients who present to the emergency department with acute chest pain. The clinical indications, 64-MDCT technique, and MDCT findings in coronary artery disease are reviewed.  相似文献   

4.
Kim YK  Ko SW  Hwang SB  Kim CS  Yu HC 《European radiology》2006,16(6):1337-1345
The aim of our study was to compare the diagnostic performance of 16--slice multidetector computed tomography with that of superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) imaging in the detection of small hepatic metastases and in the differentiation of hepatic metastases from cysts. Twenty-three patients with 55 liver metastases and 14 liver cysts underwent SPIO-enhanced MR imaging and multiphasic CT using 16-MDCT. Two observers independently analyzed each image, in random order. Sensitivity and diagnostic accuracy for lesion detection and differentiation as metastases or cysts for MDCT and SPIO-enhanced MR imaging were calculated using receiver operating characteristic analysis. For all observers, the Az values of SPIO-enhanced MR imaging for lesion detection and differentiation of liver metastases from cysts (mean 0.955, 0.999) were higher than those of MDCT (mean 0.925, 0.982), but not statistically significantly so (P>0.05). Sensitivity of SPIO-enhanced MR imaging with regard to the detection of liver metastases (mean 94.5%) was significantly higher than that of MDCT (mean 80.0%) (P<0.05). SPIO-enhanced MR imaging and 16-MDCT showed similar diagnostic accuracies for detection and differentiation of liver metastases from cysts, but sensitivity of SPIO-enhanced imaging in the detection of liver metastases was superior to that of 16-MDCT.  相似文献   

5.
多层CT辐射剂量与防护研究进展   总被引:3,自引:1,他引:2  
多层CT(MDCT)可进行快速扫描和大范围容积扫描。与单层CT(SDCT)相比,MDCT特有的参数可能增加或减少受检者剂量。早期研究表明MDCT所致受检者剂量高于SDCT,但目前越来越多的研究表明两者剂量相似甚至MDCT的剂量较低。多层CT主要依靠CT的合理使用来降低辐射剂量。CT检查正当化判断是临床医生与放射医师共同的责任。扫描参数应根据扫描指征、受检者体形、年龄及扫描范围设置,并使用自动曝光控制等降低辐射剂量的技术。对临床医生和CT工作人员进行CT辐射防护培训有助于CT检查正当化及扫描方案与辐射剂量的最优化。  相似文献   

6.
RATIONALE AND OBJECTIVES: This in vitro study was designed to improve the accuracy of coronary calcium mass measurement from computed tomography (CT) images by developing threshold-based calcium CT number correction and thin-slice spiral techniques. MATERIALS AND METHODS: A cardiac CT phantom containing simulated calcified cylinders of known calcium density was scanned with sequential 4 x 2.5-, spiral 16 x 1.5-, and spiral 16 x 0.75-mm collimation on 4- and 16-detector row CT scanners. The images obtained from the spiral scans were reconstructed in various slice widths. The calcified cylinders were imaged and their mean CT number and size were measured at thresholds ranging from 50 to 390 Hounsfield unit. The calcium mass measured was compared with the actual value to determine errors, and threshold-based correction factors were derived to minimize the errors. RESULTS: The minimum amount of measurable calcium in 1-mm cylinder was 0.3 mg at the 16 X 1.5-mm protocol and 0.2 mg at the 16 x 0.75-mm protocol. Compared with 2.5-mm sequential protocol, thin-slice spiral protocols yielded a higher radiation exposure and lower or similar image noise levels. The error in calcium mass after correction was significantly smaller than that in measured mass (P < .0001) and was consistent between the imaging protocols (P = .49). The accuracy of mass measurements was clearly improved by using thin-slice imaging protocols especially in 200-mg/cm3 calcium density (P < .0001). CONCLUSION: The accuracy of calcium mass CT measurement can be improved by threshold-based calcium CT number correction and thin collimation spiral techniques.  相似文献   

7.
AIM: To determine the usefulness of multidetector-row CT (MDCT) with multiplanar reformatted (MPR) images in the sagittal and coronal plane in diagnosing acute right hemidiaphragmatic rupture. MATERIALS AND METHODS: Twelve patients were identified who received chest and abdominal MDCT after major blunt trauma diagnosed with right diaphragmatic injury. Sagittal and coronal reformations were performed in all cases. The images were retrospectively reviewed by two experienced radiologists for signs of right diaphragm injury, such as direct diaphragm discontinuity, the "collar sign", the "dependent viscera sign", and intra-thoracic location of herniated abdominal contents. RESULTS: Of the 12 cases of right hemidiaphragm rupture, diaphragm discontinuity was seen in seven (58%) cases, the collar sign in five (42%), the dependent viscera sign in four (33%), and transdiaphragmatic herniation of the right colon and fat in another. Two variants of the collar sign were apparent on high-quality sagittal and coronal reformations. The first, termed the "hump sign", describes a rounded portion of liver herniating through the diaphragm forming a hump-shaped mass, and the second, termed the "band sign," is a linear lucency across the liver along the torn edges of the hemidiaphragm. The hump sign occurred in 10 (83%) patients and the band sign in four (33%). CONCLUSION: MDCT is very useful in the diagnosis of right hemidiaphragm injury caused by blunt trauma when sagittal and coronal reformatted images are obtained, and should allow more frequent preoperative diagnosis.  相似文献   

8.

Purpose

Motion artifacts, which can mimic thickened bronchial wall and the cystic appearance of bronchiectasis, constitute a potential pitfall in the diagnosis of interstitial or bronchial disease. Therefore, purpose of our study was to evaluate whether 64-detector row CT (64-MDCT) enables a reduction in respiratory or cardiac motion artifacts in the lung area on thin-section CT without ECG gating, and to examine the correlation between cardiac motion artifact and heart rate.

Materials and methods

Thirty-two patients with suspected diffuse lung disease, who underwent both 8- and 64-MDCT (gantry rotation time, 0.5 and 0.4 s, respectively), were included. The heart rates of an additional 155 patients were measured (range, 48–126 beats per minute; mean, 76 beats per minute) immediately prior to 64-MDCT, and compared to the degree of cardiac motion artifact. Two independent observers evaluated the following artifacts on a monitor without the knowledge of relevant clinical information: (1) artifacts on 8- and 64-MDCT images with 1.25-mm thickness and those on 64-MDCT images with 0.625-mm thickness in 32 patients; and (2) artifacts on 64-MDCT images with 0.625-mm thickness in 155 patients.

Results

Interobserver agreement was good in evaluating artifacts on 8-MDCT images with 1.25-mm thickness (weighted Kappa test, κ = 0.61–0.71), and fair or poor in the other evaluations (κ < 0.31). Two observers stated that cardiac motion artifacts were more significant on 8-MDCT than on 64-MDCT in all 32 patients. Statistically significant differences were found at various checkpoints only in comparing artifacts between 8- and 64-MDCT for 1.25-mm thickness (Wilcoxon's signed-rank test, p < 0.0017). Cardiac motion artifacts on 64-MDCT had no significant correlation with heart rate (Spearman's correlation coefficient by rank test).

Conclusion

The high temporal resolution of 64-MDCT appears to reduce cardiac motion artifact that can affect thin-section scans of the lung parenchyma.  相似文献   

9.
RATIONALE AND OBJECTIVES: The authors performed this study to evaluate the effect of window level and gray-scale threshold on the demonstration of coronary artery lumina at three-dimensional electron-beam computed tomographic (CT) angiography. MATERIALS AND METHODS: Forty-four coronary artery branches in postmortem pigs were evaluated with electron-beam CT angiography, and the findings were compared with those from conventional angiography. Images from electron-beam CT angiography were reconstructed with maximal intensity projection (MIP), multiplanar reformation (MPR), and shaded-surface display (SSD). Four categories of window level and gray-scale threshold were evaluated. RESULTS: Three-dimensional electron-beam CT angiography accurately depicted the luminal diameters of the coronary arteries compared with conventional angiography (r = 0.83-0.90, P < .0001). The length of lumina visualized at electron-beam CT angiography was significantly shorter than that visualized with conventional angiography (P < .001). The use of MPR enabled visualization of longer segments of coronary arteries than did the use of MIP or SSD (P < .05). The higher the window level and gray-scale threshold used, the smaller the coronary luminal diameters measured (P < .05). The most accurate window level and gray-scale threshold (82.6 HU +/- 29.8 and 89.5 HU +/- 29.7, respectively) were found to correspond to the attenuation of the lumina (275.8 HU +/- 58.8). Results of simple linear regression showed a strong correlation between luminal attenuation and window level (r = 0.89, P < .0001) or gray-scale threshold (r = 0.95, P < .0001). CONCLUSION: Electron-beam CT angiography shows promise in the visualization of coronary artery lumina. For accurate display of lumina, a proper window level and gray-scale threshold for three-dimensional rendering techniques should be determined and used on the basis of the attenuation of the target vessel.  相似文献   

10.
Purpose: To describe computed tomography (CT) venographic appearances of systemic-to-pulmonary venous shunts with CT venography and three-dimensional reconstruction images from patients with superior vena cava obstruction.

Material and Methods: From January 1994 to April 2002, CT venography was performed in 45 patients with superior vena cava obstruction using a single-detector helical CT scanner (n=38) and four-detector row CT scanner (n=7). Analysis of CT scan data included the cause and degree of venous obstruction, the presence of pleural thickening and enhancement, and the attenuation of pulmonary veins. The causative factor for systemic-to-pulmonary venous shunt was evaluated using the Fisher exact test.

Results: Systemic-to-pulmonary venous shunts were observed in four patients (9%) who had high-attenuated pulmonary veins and pleural enhancement on CT venography. Pleural thickening (P=0.01) and a history of pulmonary tuberculosis (P=0.034) are statistically significant risk factors.

Conclusion: CT venography showed strong pleural enhancement and high-attenuated pulmonary veins indicating systemic-to-pulmonary venous shunts. Radiologists should study the earlier enhancement of pulmonary veins in patients with superior vena cava obstruction.  相似文献   

11.
ObjectiveTo evaluate the influence of monoenergetic reconstructions using a spectral detector CT (SDCT) on the computer aided detection (CAD) of pulmonary artery embolism (PAE) on CT pulmonary angiography (CTPA) and CT in venous contrast phase (CTV).Material and MethodsA retrospective data base search identified 15 patients with CTPA and 18 patients with CTV and diagnosis of PAE. For these patients, monoenergetic (monoE) images at different energy levels or with a fixed attenuation in the pulmonary artery were generated and independently analyzed using a commercially available computer aided detection (CAD) tool. Attenuation in the pulmonary artery and in the embolus was measured.ResultsFor CTPA and CTV, in monoenergetic images the difference in attenuation between vessel and embolus was significantly higher than in conventional images. In CTPA the detection rate was highest in the >500 HU monoE images with 67,9% detected emboli and 93,3% of patients correctly identified as having PAE. At the same time the false positive rate could be significantly reduced by using monoE images compared to conventional images.Detection rates for CTV were lower than in CTPA but were raised significantly by monoE reconstructions.ConclusionsThe combination of SDCT and CAD improves the diagnostic accuracy of CAD and enables CAD interpretation of CTV.  相似文献   

12.

Objectives

To assess the effectiveness of adaptive iterative dose reduction (AIDR) and AIDR 3D in improving the image quality in low-dose chest CT (LDCT).

Materials and methods

Fifty patients underwent standard-dose chest CT (SDCT) and LDCT simultaneously, performed under automatic exposure control with noise index of 19 and 38 (for a 2-mm slice thickness), respectively. The SDCT images were reconstructed with filtered back projection (SDCT-FBP images), and the LDCT images with FBP, AIDR and AIDR 3D (LDCT-FBP, LDCT-AIDR and LDCT-AIDR 3D images, respectively). On all the 200 lung and 200 mediastinal image series, objective image noise and signal-to-noise ratio (SNR) were measured in several regions, and two blinded radiologists independently assessed the subjective image quality. Wilcoxon's signed rank sum test with Bonferroni's correction was used for the statistical analyses.

Results

The mean dose reduction in LDCT was 64.2% as compared with the dose in SDCT. LDCT-AIDR 3D images showed significantly reduced objective noise and significantly increased SNR in all regions as compared to the SDCT-FBP, LDCT-FBP and LDCT-AIDR images (all, P ≤ 0.003). In all assessments of the image quality, LDCT-AIDR 3D images were superior to LDCT-AIDR and LDCT-FBP images. The overall diagnostic acceptability of both the lung and mediastinal LDCT-AIDR 3D images was comparable to that of the lung and mediastinal SDCT-FBP images.

Conclusions

AIDR 3D is superior to AIDR. Intra-individual comparisons between SDCT and LDCT suggest that AIDR 3D allows a 64.2% reduction of the radiation dose as compared to SDCT, by substantially reducing the objective image noise and increasing the SNR, while maintaining the overall diagnostic acceptability.  相似文献   

13.
RATIONALE AND OBJECTIVES: On-call radiology residents frequently interpret computed tomography (CT) pulmonary angiography and CT venography studies outside of routine working hours. The purpose of this study was to compare resident and faculty interpretation concordance rates and to see if concordance rates differed depending on the number of CT detectors used. MATERIALS AND METHODS: The study population included 122 consecutive CT pulmonary angiography (CTPA) and CT venography (CTV) examinations performed on a four-row multidetector CT (MDCT) and 125 consecutive CTPA examinations performed using a 16-row MDCT scanner with CTV performed in 124 patients. Preliminary resident reports and final faculty reports were compared. Discrepant cases were independently reviewed by three cardiothoracic radiologists who were unaware of the initial interpretations. Interpretation concordance rates were calculated for both 4- and 16- row MDCT studies and compared using Fisher's exact test. RESULTS: Resident and faculty CTPA and CTV interpretations were concordant in 80% of the 4-row cases and 94% of the 16-row cases. When comparing resident interpretation to the final expert reference standard, the corrected resident error rate was 11% and 2% for 4-row CTPA and CTV, respectively and 4% and 2% for 16-row CTPA and CTV, respectively. Overall CTPA and CTV concordance was significantly lower for 4-row MDCT (80% versus 94%, P < .001 [two-sided] by Fisher's exact test). CONCLUSIONS: Radiology resident interpretation of CTPA and CTV studies demonstrates a high level of agreement with radiology faculty interpretation. Concordance rates are significantly higher for 16-row MDCT than 4-row MDCT which may be due to improved image quality.  相似文献   

14.
Weng MJ  Wu MT  Pan HB  Kan YY  Yang CF 《Clinical imaging》2004,28(6):408-414
PURPOSE: To assess the feasibility of low-dose CT (LDCT) in the detection of pulmonary metastases in patients with primary gynecologic malignancies and also to compare the performance of chest digital radiography (DR) and LDCT for their delectability of pulmonary metastases, with use of standard-dose CT (SDCT) as the reference standard. MATERIALS AND METHODS: Thirty female patients with primary gynecologic malignancies (age range, 20-76 years; mean age, 50 years) underwent DR, noncontrast LDCT and contrast-enhanced SDCT, which were performed within an interval of 2 weeks. We used lung nodule, mediastinal lymphadenopathy (>10 mm in the short axis) and pleural changes (including effusion, irregular thickening, or nodularity) as the cardinal imaging findings of lung metastases. A five-point scoring system was designed to indicate the probability of lung metastasis from primary gynecologic malignancies. The five-point scores of DR, LDCT, and SDCT were analyzed by receiver operating characteristic (ROC) curve. RESULTS: SDCT probability scores of +2 and -2 were set to indicate true positive and true negative for pulmonary nodule, mediastinal lymphadenopathy, and pleural effusion, respectively. All the areas under the ROC curve of LDCT appeared to be larger than those of DR[pulmonary nodule: 0.96 [95% confidence interval (CI): 0.92-1.01] vs. 0.74 [95% CI: 0.57-0.91], 0.82 [95% CI: 0.70-0.95] vs. 0.61 [95% CI: 0.50-0.77]; mediastinal lymphadenopathy: 0.98 [95% CI: 0.93-1.03] vs. 0.90 [95% CI: 0.79-1.01], 0.94 [95% CI: 0.82-1.06] vs. 0.66 [95% CI: 0.44-0.88]; and pleural effusion: 0.98 [95% CI: 0.93-1.03] vs. 0.56 [95% CI: 0.29-0.82], 0.90 [95% CI: 0.74-1.05] vs. 0.46 [95% CI: 0.23-0.68]]. CONCLUSION: The performance of LDCT were comparable to those of SDCT and superior to those of DR for detection of pulmonary nodule, mediastinal lymphadenopathy, and pleural effusion. By using LDCT, there was no need of intravenous contrast injection and less radiation exposure. We propose a protocol including standard-dose abdominal CT and low-dose chest CT for the initial and follow-up stagings of primary gynecologic malignancy. The use of chest DR is unnecessary.  相似文献   

15.
The aim of this study was to assess retrospectively the value of adding coronal reformation images to the identification of the normal appendix using 64-slice multidetector CT (MDCT). 200 consecutive healthy adults with no history of abdominal surgery underwent abdominal CT using 64-slice MDCT without oral contrast administration and were enrolled in the study. Two gastrointestinal radiologists first interpreted the axial images only; after a 2-week interval, they then interpreted both the axial and the coronal images while blinded to the first interpretation. The identification of the normal appendix was interpreted using a four-point scale: 1, not identified; 2, identified with low confidence; 3, probably identified; 4, definitely identified. Agreement between the readers was determined with the use of weighted kappa statistics. Differences in confidence ratings for identification of the appendix were determined with the Wilcoxon signed rank test. The agreement between the readers was higher when both axial and coronal images were reviewed (kappa = 0.85) than when only the axial scans images were reviewed (kappa = 0.43). The mean confidence scores for the identification of the normal appendix by the two readers were significantly higher when both the axial and coronal images were reviewed (mean, 3.81+/-0.498 and 3.83+/-0.485 for the two readers, respectively) than when only the axial images were reviewed (mean, 3.27+/-0.819 and 3.47+/-0.856, respectively) (all p<0.01). Therefore, adding coronal reformation images to 64-slice MDCT significantly improves inter-reader agreement and confidence in the identification of the normal appendix.  相似文献   

16.
ObjectiveTo evaluate the image quality and lesion detectability of lower-dose CT (LDCT) of the abdomen and pelvis obtained using a deep learning image reconstruction (DLIR) algorithm compared with those of standard-dose CT (SDCT) images.Materials and MethodsThis retrospective study included 123 patients (mean age ± standard deviation, 63 ± 11 years; male:female, 70:53) who underwent contrast-enhanced abdominopelvic LDCT between May and August 2020 and had prior SDCT obtained using the same CT scanner within a year. LDCT images were reconstructed with hybrid iterative reconstruction (h-IR) and DLIR at medium and high strengths (DLIR-M and DLIR-H), while SDCT images were reconstructed with h-IR. For quantitative image quality analysis, image noise, signal-to-noise ratio, and contrast-to-noise ratio were measured in the liver, muscle, and aorta. Among the three different LDCT reconstruction algorithms, the one showing the smallest difference in quantitative parameters from those of SDCT images was selected for qualitative image quality analysis and lesion detectability evaluation. For qualitative analysis, overall image quality, image noise, image sharpness, image texture, and lesion conspicuity were graded using a 5-point scale by two radiologists. Observer performance in focal liver lesion detection was evaluated by comparing the jackknife free-response receiver operating characteristic figures-of-merit (FOM).ResultsLDCT (35.1% dose reduction compared with SDCT) images obtained using DLIR-M showed similar quantitative measures to those of SDCT with h-IR images. All qualitative parameters of LDCT with DLIR-M images but image texture were similar to or significantly better than those of SDCT with h-IR images. The lesion detectability on LDCT with DLIR-M images was not significantly different from that of SDCT with h-IR images (reader-averaged FOM, 0.887 vs. 0.874, respectively; p = 0.581).ConclusionOverall image quality and detectability of focal liver lesions is preserved in contrast-enhanced abdominopelvic LDCT obtained with DLIR-M relative to those in SDCT with h-IR.  相似文献   

17.
The purpose of this study was to assess the effectiveness of double reading to increase the sensitivity of lung nodule detection at standard-dose (SDCT) and low-dose multirow-detector CT (LDCT). SDCT (100 mAs effective tube current) and LDCT (20 mAs) of nine patients with pulmonary metastases were obtained within 5 min using four-row detector CT. Softcopy images reconstructed with 5-mm slice thickness were read by three radiologists independently. Images with 1.25-mm slice thickness served as the gold standard. Sensitivity was assessed for single readers and combinations. The effectiveness of double reading was expressed as the increase of sensitivity. Average sensitivity for detection of 390 nodules (size 3.9±3.2 mm) for single readers was 0.63 (SDCT) and 0.64 (LDCT). Double reading significantly increased sensitivity to 0.74 and 0.79, respectively. No significant difference between sensitivity at SDCT and LDCT was observed. The percentage of nodules detected by all three readers concordantly was 52% for SDCT and 47% for LDCT. Although double reading increased the detection rate of pulmonary nodules from 63% to 74–79%, a considerable proportion of nodules remained undetected. No difference between sensitivities at LDCT and SDCT for detection of small nodules was observed.  相似文献   

18.
Development of perfusion CT software for personal computers   总被引:3,自引:0,他引:3  
RATIONALE AND OBJECTIVES: The authors developed software for creating quantitative maps of arterial and portal perfusion in the upper abdominal organs on personal computers. The image quality of these perfusion computed tomographic (CT) images was visually evaluated. MATERIALS AND METHODS: In 58 patients (38 men, 20 women; mean age, 63.9 years +/- 11.9; range, 22-85 years) with various diseases of the upper abdomen, 91 single-section dynamic CT studies were obtained. The data were transferred on-line to a personal computer, and quantitative maps of arterial and portal perfusion were created by means of the maximum-slope method. Perfusion CT images were reviewed by a radiologist and a radiation technologist, and image quality was rated according to a four-category scoring system (1 = good quality, 2 = moderate, 3 = poor, 4 = images could not be created). RESULTS: Arterial perfusion CT images could be created in 81 (89%) of 91 examinations, and 74 images (81%) were scored as 1 or 2. Portal perfusion CT images could be created in 60 (68%) of 88 examinations, in which a portal trunk was included in the section, and 33 of them (38%) were scored as 1 or 2. Patient motion during dynamic CT sequences resulted in poor image quality in seven arterial and 27 portal perfusion images. CONCLUSION: Perfusion CT can combine quantitative perfusion maps with good anatomic detail in one image, although patient movement frequently degrades image quality in portal perfusion CT.  相似文献   

19.
RATIONALE AND OBJECTIVES: To improve effective scan time and image quality in cone-beam computed tomography (CT), Parker's weighting function (half scan [HS]-Feldkamp-Davis-Kress [FDK]) extended to a larger range up to 2pi was proposed as new half-scan algorithm (NHS-FDK). We conducted a practical physical evaluation of NHS-FDK and HS-FDK using 256-detector row CT. MATERIALS AND METHODS: Three types of weighting function (full-scan [FS-FDK], HS-FDK, and NHS-FDK) were evaluated by using 256-detector row CT for five variables, ie, point spread function, image noise, CT number uniformity, Feldkamp artifact, temporal resolution, and clinical evaluation. RESULTS: Image noise, Feldkamp artifact, and temporal resolution were dependent on weighting function. Image noise magnitude was independent of projection angle for all regions of interest with FS-FDK, but showed a symmetric pattern with projection angle with HS-FDK and NHS-FDK. With regard to temporal resolution, NHS-FDK did not remove the motion artifact in the heart except in such slower motion organs as the pulmonary vessels, whereas HS-FDK reduced the motion artifact in the heart. HS-FDK had an even more incomplete data region in the Radon space than FS-FDK, suggesting that it would provide poor image quality distant to the midplane in the longitudinal direction. In practical testing in human subjects, HS-FDK showed inferior performance in all variables except temporal resolution. CONCLUSION: Despite its inferiority to FS-FDK for static objects, HS-FDK may be useful in chest imaging. Contrary to previous findings using static images, NHS-FDK failed to show advantages over HS-FDK or FS-FDK in a moving phantom and human subjects.  相似文献   

20.
BACKGROUND AND PURPOSE: The purpose of this work was to evaluate the possible use of low-dose multidetector CT (MDCT) in cervical clearance of patients with blunt trauma. MATERIALS AND METHODS: A total of 191 patients underwent cervical spine MDCT with 6- and 16-MDCT: standard-dose (n = 51) and low-dose MDCT with tube current modulation at high (n = 70) and low (n = 70) tube voltage (kilovolts). Effective dose, image noise, and subjective image quality were calculated in all of the patients. RESULTS: MDCT found 18 patients (9.4%) with a cervical spine fracture, 3 in the standard-dose and 15 in the low-dose group, 14 of them with unstable lesions. Tube current modulation reduced the dose by 50%-61% in all of the low-dose examinations. The mean effective dose was 3.75, 1.57, and 1.08 mSv, and mean image noise was 14.82, 17.46, and 19.72 Hounsfield units for standard dose and low dose with high and low kilovolt examinations, respectively. These differences in mean effective dose and image noise were significant between the 3 examination groups (Kruskal-Wallis test: P < .0001 and P = .0001). Evaluation of subjective image quality by 2 radiologists and 2 residents showed no significant difference in image quality score among the 3 examination groups (Kruskal-Wallis tests, P = .61, .32, .18, and .31). All of the reviewers correctly detected 18 fractures, except 1 resident, who missed 3 fractures. CONCLUSION: Low-dose cervical spine MDCT in patients with blunt trauma gives a substantial dose reduction of 61%-71%, compared with standard-dose MDCT, with a small increase in image noise and without difference in subjective image quality evaluation.  相似文献   