首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PURPOSE: To prospectively compare unenhanced power Doppler sonographic findings of arterial vascularization of invasive breast carcinoma with histopathologic and immunohistochemical parameters and to determine whether tumor arterial vascularization contributes to prediction of axillary node status. MATERIALS AND METHODS: Ethics committee approval and informed consent were obtained. A total of 97 invasive breast carcinomas were prospectively studied with unenhanced power Doppler sonography before surgery. Lumpectomy or mastectomy with full axillary nodal dissection was performed. Sonographic tumor size and number of tumor arteries were correlated with axillary nodal status by means of logistic regression analysis. Tumor microvascularization was immunohistochemically assessed in a subset of 55 carcinomas. Sonographic variables were correlated with tumor arteries with a diameter larger than 300 mum and with the density and area of microvascularization. The kappa statistic and Bland-Altman agreement limits were used to measure agreement between techniques. RESULTS: Good agreement of sonographic and histologic findings regarding number of tumor arteries (kappa= 0.66, P < .001) and tumor size (P = .012) was observed. Multivariate analysis showed an independent relationship between probability of axillary metastasis, number of tumor arteries (P = .016), and sonographic tumor size (P = .035). A predictive model of axillary status was developed. The receiver operating characteristic curve was used to determine 0.2324 as the score to classify axillary nodal status. This score indicated high sensitivity (96.1%), low specificity (53.0%), and high negative predictive value (96.1%). CONCLUSION: The number of arteries in invasive breast carcinoma detected with unenhanced power Doppler sonography and sonographic tumor size are independent predictors of axillary nodal status; these variables could contribute to reliable prediction of absence of axillary involvement on the basis of a mathematic model.  相似文献   

2.
OBJECTIVE: The purpose of our study was to determine how breast cancer vascularity, as revealed by power Doppler sonography, correlates with lymph node involvement and lymphatic vascular invasion. MATERIALS AND METHODS: Breast sonograms obtained during a 2-year period were retrospectively reviewed. Patients who underwent power Doppler sonography of solid masses and had biopsy-proven carcinoma composed our study population. Power Doppler findings were categorized according to the presence or absence of vessels. Pathologic findings were reviewed for lymph node involvement and lymphatic vascular invasion. RESULTS: Of 176 patients with breast cancer, vessels were seen on power Doppler sonography in 128 (73%) and not seen in 48 (27%). Of 126 patients who underwent lymph node dissection, vessels were seen in 97 (77%) and not seen in 29 (23%). Lymph node involvement was seen in 42 (43%) of the 97 patients in whom vessels were seen and in three (10%) of the 29 in whom vessels were not seen. Of 150 patients examined for lymphatic vascular invasion, vessels were seen in 111 (74%) and not seen in 39 (26%). Lymphatic vascular invasion was seen in 47 (42%) of the 111 patients in whom vessels were seen and in five (13%) of the 39 in whom vessels were not seen. CONCLUSION: Tumor vascularity revealed by power Doppler sonography correlated strongly with detection of lymph node involvement and lymphatic vascular invasion, with sensitivities of 93% and 90%, respectively. However, the specificities were low, at 32% and 35%, respectively. More important, patients with breast cancer in whom vessels were not revealed by power Doppler sonography also were unlikely to have lymph node involvement and lymphatic vascular invasion: Negative predictive values were 90% and 87%, respectively.  相似文献   

3.
Graf O  Helbich TH  Hopf G  Graf C  Sickles EA 《Radiology》2007,244(1):87-93
PURPOSE: To retrospectively determine whether nonpalpable solid breast masses that were partially or completely obscured at mammography and diagnosed as probably benign only at ultrasonography (US) can be safely managed with follow-up. MATERIALS AND METHODS: The local ethics committee approved this study; informed consent was not required. In 409 women, 448 nonpalpable solid masses were identified and classified as probably benign at US; at mammography these masses were either partially or completely obscured by dense fibroglandular tissue. Of the 448 masses, 445 were followed up, while biopsy was performed after initial imaging in the remaining three. False-negative rates, negative predictive values (NPVs), and exact 95% confidence intervals (CIs) were calculated. RESULTS: Of the 445 masses, 442 remained stable at follow-up (range, 2-5 years; mean, 3.3 years). Two masses increased (fibroadenomas at biopsy). One mass became palpable, and cancer was diagnosed at biopsy. The three masses in which initial biopsy was performed were fibroadenomas. The false-negative rate was 0.2% (one of 448; NPV, 99.8%; 95%CI: 0.0%, 1.23%). CONCLUSION: Follow-up US appears to be an acceptable alternative to biopsy for solid masses with benign morphologic features seen at US owing to the extremely high NPV (99.8%).  相似文献   

4.

Objective

To investigate the factors that have an effect on false-positive or false-negative shear-wave elastography (SWE) results in solid breast masses.

Methods

From June to December 2012, 222 breast lesions of 199 consecutive women (mean age: 45.3?±?10.1 years; range, 21 to 88 years) who had been scheduled for biopsy or surgical excision were included. Greyscale ultrasound and SWE were performed in all women before biopsy. Final ultrasound assessments and SWE parameters (pattern classification and maximum elasticity) were recorded and compared with histopathology results. Patient and lesion factors in the ‘true’ and ‘false’ groups were compared.

Results

Of the 222 masses, 175 (78.8 %) were benign, and 47 (21.2 %) were malignant. False-positive rates of benign masses were significantly higher than false-negative rates of malignancy in SWE patterns, 36.6 % to 6.4 % (P?<?0.001). Among both benign and malignant masses, factors showing significance among false SWE features were lesion size, breast thickness and lesion depth (all P?<?0.05). All 47 malignant breast masses had SWE images of good quality.

Conclusions

False SWE features were more significantly seen in benign masses. Lesion size, breast thickness and lesion depth have significance in producing false results, and this needs consideration in SWE image acquisition.

Key Points

? Shear-wave elastography (SWE) is widely used during breast imaging ? At SWE, false-positive rates were significantly higher than false-negative rates ? Larger size, breast thickness, depth and fair quality influences false-positive SWE features ? Smaller size, larger breast thickness and depth influences false-negative SWE features  相似文献   

5.
PURPOSE: To determine whether palpable noncalcified solid breast masses with benign morphology at mammography and ultrasonography (US) can be managed similarly to nonpalpable probably benign lesions (Breast Imaging Reporting and Data System [BI-RADS] category 3)-that is, with periodic imaging surveillance-and to determine whether biopsy can be averted in these lesions. MATERIALS AND METHODS: No institutional review board approval or patient consent was required. This retrospective analysis, based on final imaging reports, included 152 patients (age range, 28-77 years; mean age, 48.3 years) with 157 palpable noncalcified solid masses that were classified as probably benign at initial mammography and US. Of 152 patients, 108 underwent follow-up with mammography and US (6-month intervals for 2 years, then 12-month intervals). The remaining 44 patients underwent surgical or needle biopsy after initial imaging. Lesions were analyzed at initial and follow-up examinations. Statistical analysis included Student t test and corresponding exact 95% confidence intervals. RESULTS: In 108 patients who underwent follow-up only, 112 lesions were palpable. In 102 (94.4%) of 108 patients, masses remained stable during follow-up. Lesions were followed for at least 2 years (mean, 4.1 years; range, 2-7 years). In six (5.6%) patients, palpable lesions increased in size during follow-up; these lesions were benign at subsequent open biopsy. No breast carcinoma was diagnosed in the 44 patients with 45 palpable lesions who underwent biopsy after initial imaging. Of 157 lesions, no malignant tumors were observed (exact one-sided 95% confidence interval: 0%, 1.95%). CONCLUSION: The data strongly suggest that palpable noncalcified solid breast masses with benign morphology at mammography and US can be managed similarly to nonpalpable BI-RADS category 3 lesions, with short-term follow-up (6-month intervals for 2 years). More data, based on a larger series, are required to determine whether this conclusion is correct.  相似文献   

6.

Objective

To evaluate which shear wave elastography (SWE) parameter proves most accurate in the differential diagnosis of solid breast masses.

Methods

One hundred and fifty-six breast lesions in 139 consecutive women (mean age: 43.54?±?9.94 years, range 21–88 years), who had been scheduled for ultrasound-guided breast biopsy, were included. Conventional ultrasound and SWE were performed in all women before biopsy procedures. Ultrasound BI-RADS final assessment and SWE parameters were recorded. Diagnostic performance of each SWE parameter was calculated and compared with those obtained when applying cut-off values of previously published data. Performance of conventional ultrasound and ultrasound combined with each parameter was also compared.

Results

Of the 156 breast masses, 120 (76.9 %) were benign and 36 (23.1 %) malignant. Maximum stiffness (Emax) with a cut-off of 82.3 kPa had the highest area under the receiver operating characteristics curve (Az) value compared with other SWE parameters, 0.860 (sensitivity 88.9 %, specificity 77.5 %, accuracy 80.1 %). Az values of conventional ultrasound combined with each SWE parameter showed lower (but not significantly) values than with conventional ultrasound alone.

Conclusions

Maximum stiffness (82.3 kPa) provided the best diagnostic performance. However the overall diagnostic performance of ultrasound plus SWE was not significantly better than that of conventional ultrasound alone.

Key Points

? SWE offers new information over and above conventional breast ultrasound ? Various SWE parameters were explored regarding distinction between benign and malignant lesions ? An elasticity of 82.3 kPa appears optimal in differentiating solid breast masses ? However, ultrasound plus SWE was not significantly better than conventional ultrasound alone  相似文献   

7.
8.
9.
AIM: To determine whether colour Doppler sonograms can be used to differentiate between the normal appendix and acute appendicitis. MATERIAL AND METHODS: This prospective study examined 50 consecutive children with suspected appendicitis using grey-scale and colour Doppler US. Appendicitis was diagnosed when the appendix diameter was greater than 6 mm. Blood flow on the appendiceal wall was measured and classified as non-existent (0 pixels), low (1-2), moderate (3-4) or abundant (>4). Likelihood ratios were calculated for each of these levels. The diagnosis of acute appendicitis was confirmed by pathological findings, and ruled out by clinical follow-up or pathological findings. RESULTS: Of the 50 patients examined, 24 had appendicitis and 26 had a normal appendix. For 25 of the patients with a normal appendix, appendicitis was ruled out by clinical follow-up, and for one patient, by pathological findings. The abnormal appendix was identified in all patients with appendicitis. In the group of 26 patients without appendicitis, the normal appendix was visualized in 23 cases, one of which was false positive (100% sensitivity, 96% specificity). Abnormal appendices showed moderate to abundant flow in 62% of the cases and non-existent or low flow in 38%. Normal appendices had non-existent or low flow in 82% of the cases, but moderate or abundant in 18%. Significant differences were only found when the number of pixels was >4. CONCLUSION: Although the vascularity of normal and inflamed appendices may be different, this difference was not a good diagnostic indicator of appendicitis.  相似文献   

10.
11.
PURPOSE This study assessed the role of renal power Doppler ultrasonography (PDU) to identify acute pyelonephritis (APN) and to determine whether PDU can replace Tc-99m DMSA renal scintigraphy in the diagnosis of APN in children.METHODS A prospective study was conducted in 40 infants and young children (78 kidneys were evaluated) with a mean age of 25.9 months (range, 1 to 68 months) who were hospitalized with a first episode of high fever and bacteruria, possibly APN. All children were examined by PDU and Tc-99m DMSA within the first 3 days after admission. Patients with congenital abnormalities, hydronephrosis, and urinary reflux were excluded.RESULTS Twenty-seven of the 78 kidneys appeared abnormal on Tc-99m DMSA, and 20 of them were abnormal on PDU. Fifty-one of 78 kidneys were normal on Tc-99m DMSA, and 3 of 51 appeared diseased on PDU. The accuracy of PDU was 87%, sensitivity was 74%, and specificity was 94%. The positive predictive and negative predictive values were both 87%. When considering the numbers of lesions in 27 kidneys with positive Tc-99m DMSA studies (38 lesions), PDU did not disclose 16 lesions (false-negative results). Thus, the sensitivity of PDU for diagnosing lesions of APN decreased to 58%.CONCLUSIONS A positive PDU finding should obviate the use of Tc-99m DMSA in patients thought to have possible APN. However, because of a large number of false-negative results (26%) and underestimation of the number of pyelonephritic lesions (low sensitivity of 58%), PDU cannot replace Tc-99m DMSA in the diagnosis of APN in children.  相似文献   

12.

Objective

The objective of our study is to evaluate the contribution of adding MRI findings to sonographic data when assessing fetal anomalies and to determine how this addition may affect the management of pregnancy.

Study design

We prospectively examined 26 fetuses who had sonographically suspected congenital anomalies over a period of 1 year. 2D/3D and 4D ultrasound, Doppler and magnetic resonant imaging was done for all patients. MRI was done within 1 week following US examination. The maternal age range was 18-39 years. The gestational age range was 15-38 weeks (mean age = 29 weeks). Ultrasound and magnetic resonance findings were compared together.

Results

We reported different types of congenital anomalies including eight cases of isolated central nervous system anomalies, four abdominal, five musculoskeletal anomalies, seven cases of renal anomalies and two cases of Meckel Gruber syndrome. MRI and sonography showed concordant findings in 18 cases. MRI changed the diagnosis in five cases and provided additional information in three cases. Ultrasound was superior to magnetic resonance imaging in three cases.

Conclusion

Our results showed that fetal MR imaging can be used as a complementary modality to US in diagnosing fetal abnormality in which US findings are inconclusive or equivocal.  相似文献   

13.
Imaging sentinel nodes with pre-operative lymphoscintigraphy effectively assures successful sentinel node identification. However, sentinel nodes are still identified in the majority of image negative patients. Given the logistics and cost required to perform pre-operative lymphoscintigraphy its routine use may not be justified. It may be valuable for surgeons in the learning phase and in obese patients who have increased risk of intra-operative failed localization. A negative pre-operative lymphoscintiscan predicts inability to localize with the hand-held gamma probe. Patients with no 'hot node' on the lymphoscintiscan are more likely to have failed localization using the gamma probe only. Therefore, blue dye should be used along with the gamma probe to optimize the localization rate in these patients.  相似文献   

14.

Objectives

This study investigated whether diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) values provide specific information that allows the diagnosis of solid or predominantly solid gynaecological adnexial lesions, especially whether they can discriminate benign and malignant lesions.

Methods

DWI was performed in 37 patients with histologically proven solid or predominantly solid adnexial lesions (22 malignant and 15 benign neoplasms). The lesions in our data set were divided into two groups, all adnexial lesions or lesions of ovarian origin, for evaluation. The areas of the highest signal intensity on DWI (b = 800 s mm−2) and the lowest ADC values within the lesions were evaluated.

Results

On DWI, high signal intensity was observed more often in malignant than in benign lesions (p<0.0001). There was no significant difference between the ADC values of the malignant and benign lesions in either the adnexial (0.88±0.16 vs 0.84±0.42; p = 0.96) or the ovarian (0.85±0.14 vs 1.05±0.2; p = 0.133) lesions. When signal intensities on DWI were compared, however, malignant lesions had higher values than the benign lesions in both the adnexial (0.69±0.21 vs 0.29±0.13; p<0.0001) and the ovarian lesions (0.75±0.14 vs 0.37±0.24; p = 0.003).

Conclusion

On DWI, high signal intensity was observed more frequently with the malignant lesions.MRI plays an important role in the diagnosis of gynaecological adnexial lesions [1-4]. It provides useful information for the characterisation of various ovarian, uterine and tubal masses. Some morphological and signal intensity features of the lesions on MRI are very important for the differential diagnosis [5], but this information may sometimes be non-specific. Many studies have looked at the utility of diffusion-weighted MRI in the differential diagnosis of benign and malignant gynaecological lesions [6]. In particular, the contributions of diffusion-weighted imaging (DWI) and apparent diffusion coefficient (ADC) values in differentiating between cystic benign lesions and malignant ovarian and uterine lesions have been evaluated [6]. Only one investigation used DWI to assess the solid components of ovarian lesions in a wide study population [11]. To our knowledge, the utility of DWI and ADC values in assessing solid or predominantly solid gynaecological adnexial masses has not been investigated previously.In this study, our goal was to investigate whether DWI and ADC values provide specific information that can diagnose solid or predominantly solid gynaecological adnexial lesions, in particular, whether these parameters can discriminate benign and malignant lesions.  相似文献   

15.

Purpose

Real-time virtual sonography (RVS) allows displaying and synchronizing real-time US and multiplanar reconstruction of MRI images. The purpose of this study was to evaluate the feasibility and ability of RVS to assess adenomyosis since literature shows US itself has a reduced diagnostic accuracy compared to MRI.

Materials and methods

This study was conducted over a 4-month period (March–June 2015). We enrolled in the study 52 women with clinical symptoms of dysmenorrhea, methrorragia and infertility. Every patient underwent an endovaginal US examination, followed by a 3T MRI exam and a RVS exam (Hitachi HI Vision Ascendus). The MRI image dataset acquired at the time of the examination was loaded into the fusion system and displayed together with the US images. Both sets of images were then manually synchronized and images were registered using multiple plane MR imaging. Radiologist was asked to report all three examinations separately.

Results

On a total of 52 patients, on standard endovaginal US, adenomyosis was detected in 27 cases: of these, 21 presented diffuse adenomyosis, and 6 cases focal form of adenomyosis. MRI detected adenomyosis in 30 cases: 22 of these appeared as diffuse form and 8 as focal form, such as adenomyoma and adenomyotic cyst, thus resulting in 3 misdiagnosed cases on US. RVS confirmed all 22 cases of diffuse adenomyosis and all 8 cases of focal adenomyosis.

Conclusions

Thanks to information from both US and MRI, fusion imaging allows better identification of adenomyosis and could improve the performance of ultrasound operator thus to implement the contribution of TVUS in daily practice.
  相似文献   

16.
Kim KA  Park CM  Park SW  Cha SH  Seol HY  Cha IH  Lee CH  Lee KY 《Clinical imaging》2002,26(5):319-324
Thirteen patients with gallbladder disease underwent power Doppler ultrasound (PDUS) before and after microbubble contrast agent injection. Lesion and liver bed vascularity was evaluated. Pathological diagnoses in nine patients were two acute cholecystitis, four chronic inflammation, one adenoma and two adenocarcinoma. Two cases of cancer were included on clinical and radiological findings. Two cases were excluded because no pathologic diagnosis was available. Liver bed hyperemia was noted only in acute cholecystitis. Contrast-enhanced PDUS was superior to nonenhanced PDUS in the demonstration of vascularity of gallbladder diseases. However, contrast-enhanced PDUS has limited value in the differentiation.  相似文献   

17.
PURPOSE: To evaluate the value of power Doppler sonography (PDS) in patients with a serum PSA level greater than 3.5 ng/ml and note the advantages of PDS in management of biopsy cores and staging in prostate cancer. MATERIAL AND METHODS: A group of 579 patients with a serum PSA level greater than 3.5 ng/ml underwent sextant biopsies. PDS of the prostate was performed in all patients before biopsy indication. Patients underwent six initial sextant biopsies without Doppler. In 141 patients who retained an elevated serum PSA level, an additional series of six to eight ultrasound-guided biopsies with Doppler were indicated. A total of 299 cancers were diagnosed (126 palpable) after initial biopsies and 85 (13 palpable) after additional biopsies. One hundred seven patients with localized cancer (48 palpable) underwent a radical prostatectomy. RESULTS: An echographic or vascular anomaly was detected in 335 patients; after biopsies this anomaly corresponded to 260 cancers, 39 of which were not visible (false-negative Doppler results). The negative predictive value was 84% and there was no significant relation between PSA level and negative predictive value. After initial biopsies, if an abnormal Doppler signal was present the risk of having positive additional biopsies was 83%. Abnormal disoriented irregular vessels were present in 69% of patients with a Gleason score of 7 or higher versus 31% in patients with a Gleason score less than 7 (p<0.01). Twenty out of 39 patients with T1c cancer invisible with PDS and not palpable (13% of all cancers) underwent a radical prostatectomy. Eleven of 16 cancers with a Gleason score of 6 or less were found insignificant, but in two cases the lesion was advanced (p<0.01). Of cancers with a tumor vessel crossing the capsule, 71% presented an extraprostatic extension (Se: 37.5%, Spe: 93%, PPV: 71%, NPV: 78%) (p<0.01). CONCLUSION: In prostatic cancer, PDS allows evaluation of aggressiveness features and can optimize the number of useful biopsy cores.  相似文献   

18.

Objective

To investigate the accuracy of quantitative diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) mapping for characterizing soft tissue masses (STMs) as cysts or solid masses.

Materials and methods

This IRB-approved retrospective study included 36 subjects with 37 STMs imaged by conventional MRI (T1-weighted, T2-weighted, contrast-enhanced T1-weighted sequences) and DWI (b-values 50, 400, 800 s/mm2) with ADC mapping. STMs were defined as non-solid cysts by histology or clinical follow-up, and as solid by histology. For each STM, ADC values (range, mean) were recorded by two observers. Differences between ADC values in cysts and solid STMs were compared using Wilcoxon rank-sum and receiver-operating characteristic (ROC) analysis.

Results

There were higher minimum (1.65 vs 0.68, p?=?0.003) and mean (2.31 vs 1.45, p?=?0.005) ADC values in cysts than solid STMs respectively. Areas under the ROC for minimum and mean ADC values were 0.82 and 0.81 respectively. Using threshold ADC values of 1.8 (minimum) or 2.5 (mean) yielded a sensitivity of 60 % and 80 % respectively, and a specificity of 100 % for classifying a STM as a cyst; for tumors with high fluid–signal intensity, the performance of these threshold values was maintained.

Conclusion

Diffusion-weighted imaging with ADC mapping provides a non-contrast MRI alternative for the characterization of STMs as cysts or solid masses. Threshold ADC values exist that provide 100 % specificity for differentiating cysts and solid STMs, even for tumors of high fluid–signal intensity on T2-weighted images.  相似文献   

19.
20.
OBJECTIVE: The purpose of this study was to evaluate percutaneous imaging-guided core biopsy in the assessment of selected palpable breast masses. MATERIALS AND METHODS: Of 1388 consecutive breast lesions that had percutaneous imaging-guided core biopsy, 155 (11%) were palpable. Palpable masses referred for percutaneous imaging-guided core biopsy included lesions that were small, deep, mobile, vaguely palpable, or multiple. Biopsy guidance was sonography in 140 lesions (90%) and stereotaxis in 15 (10%). Surgical correlation or minimum of 2 years follow-up is available in 115 palpable masses in 107 women. Medical records, imaging studies, and histologic findings were reviewed. RESULTS: Of 115 palpable breast masses, 98 (85%) were referred by surgeons to the radiology department for percutaneous imaging-guided core biopsy and 88 (77%) had percutaneous imaging-guided core biopsy on the day of initial evaluation at our institution. Percutaneous imaging-guided core biopsy spared additional diagnostic tissue sampling in 79 (74%) of 107 women, including 57 women with carcinoma and 22 women with benign findings. Percutaneous imaging-guided core biopsy did not spare additional tissue sampling in 28 women (26%), including 15 women in whom surgical biopsy was recommended on the basis of percutaneous biopsy findings and 13 women with benign (n = 7) or malignant (n = 6) percutaneous biopsy findings who chose to undergo diagnostic surgical biopsy. CONCLUSION: Percutaneous imaging-guided core biopsy is useful in the evaluation of palpable breast masses that are small, deep, mobile, vaguely palpable, or multiple. In this study, percutaneous imaging-guided core biopsy spared additional diagnostic tissue sampling in 74% women with palpable breast masses.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号