OBJECTIVE:

To determine whether there is any influence of systemic arterial hypertension on the peripheral auditory system.

METHODS:

This was a cross-sectional study that investigated 40 individuals between 30 and 50 years old, who were divided into groups with and without systemic arterial hypertension, using data from high-frequency audiometry, transient-evoked otoacoustic emissions and distortion-product otoacoustic emissions. The results were compared with those from groups of normal-hearing individuals, with and without systemic arterial hypertension, who underwent the pure-tone audiometry test. All individuals also underwent the following procedures: otoscopy, acoustic immittance measures, pure-tone audiometry at frequencies from 250 to 16000 Hz, transient-evoked otoacoustic emissions test and distortion-product otoacoustic emissions test.

RESULTS:

No statistically significant difference was observed between the groups with and without systemic arterial hypertension in either conventional or high-frequency audiometry. Regarding transient-evoked otoacoustic emissions, there was a trend toward statistical significance whereby the systemic arterial hypertension group showed lower results. Regarding distortion-product otoacoustic emissions, the systemic arterial hypertension group showed significantly lower results at the following frequencies: 1501, 2002, and 3003 Hz. A discriminant analysis indicated that the distortion-product otoacoustic emissions variables best distinguished individuals with and without systemic arterial hypertension.

CONCLUSION:

Data from this study suggest cochlear dysfunction in individuals with systemic arterial hypertension because their otoacoustic emission results were lower than those in the systemic arterial hypertension group.  相似文献   

2.

OBJECTIVES:

We evaluated the central auditory pathways in workers with noise-induced tinnitus with normal hearing thresholds, compared the auditory brainstem response results in groups with and without tinnitus and correlated the tinnitus location to the auditory brainstem response findings in individuals with a history of occupational noise exposure.

METHOD:

Sixty individuals participated in the study and the following procedures were performed: anamnesis, immittance measures, pure-tone air conduction thresholds at all frequencies between 0.25–8 kHz and auditory brainstem response.

RESULTS:

The mean auditory brainstem response latencies were lower in the Control group than in the Tinnitus group, but no significant differences between the groups were observed. Qualitative analysis showed more alterations in the lower brainstem in the Tinnitus group. The strongest relationship between tinnitus location and auditory brainstem response alterations was detected in individuals with bilateral tinnitus and bilateral auditory brainstem response alterations compared with patients with unilateral alterations.

CONCLUSION:

Our findings suggest the occurrence of a possible dysfunction in the central auditory nervous system (brainstem) in individuals with noise-induced tinnitus and a normal hearing threshold.  相似文献   

3.

OBJECTIVE:

The aim of this study was to determine the effects of occupational noise on sound localization in different spatial planes and frequencies among normal hearing firefighters.

METHOD:

A total of 29 adults with pure-tone hearing thresholds below 25 dB took part in the study. The participants were divided into a group of 19 firefighters exposed to occupational noise and a control group of 10 adults who were not exposed to such noise. All subjects were assigned a sound localization task involving 117 stimuli from 13 sound sources that were spatially distributed in horizontal, vertical, midsagittal and transverse planes. The three stimuli, which were square waves with fundamental frequencies of 500, 2,000 and 4,000 Hz, were presented at a sound level of 70 dB and were randomly repeated three times from each sound source. The angle between the speaker''s axis in the same plane was 45°, and the distance to the subject was 1 m.

RESULT:

The results demonstrate that the sound localization ability of the firefighters was significantly lower (p<0.01) than that of the control group.

CONCLUSION:

Exposure to occupational noise, even when not resulting in hearing loss, may lead to a diminished ability to locate a sound source.  相似文献   

4.

Introduction:

In the surgical management of cholesteatoma, one can opt for a closed technique (simple mastoidectomy) or open surgery (radical mastoidectomy). Open mastoidectomy with reconstruction of the posterior wall and the middle ear in a single surgery combines the advantages of both techniques, namely, adequate surgical exposure, eradication of cholesteatoma, and anatomical reconstruction of the middle ear structures.

Objective:

To evaluate the surgical results in the management of cholesteatoma through the technique of open mastoidectomy with reconstruction of the posterior wall and the middle ear in a single surgery.

Methods:

Prospective analytical observational study conducted between 2009 and 2012 with patients undergoing this surgical technique in the Hospital Universitario del Valle [University Hospital of Valle], performing preoperative clinical monitoring and quarterly postoperative tomography with previous assessments of hearing and pre- and postoperative audiometry.

Results:

Forty-five patients were studied. Mean postoperative follow-up was 28 months. Surgical success was achieved in 93.3% of patients, as measured by clinical and radiological follow-up. Hearing preservation was found after reconstruction of the hearing mechanism, based on measured audiometry, i.e., pure-tone average (PTA), using the statistical test for paired samples between preoperative and postoperative PTA. (95%CI -1.47-12.15). Residual cholesteatoma was present in 6.6% of cases; three to four times lower than the rate reported in the literature.

Conclusions:

This type of surgery can be considered a successful technique in the treatment of cholesteatoma in selected cases.  相似文献   

5.

INTRODUCTION:

The ASSR test is an electrophysiological test that evaluates, among other aspects, neural synchrony, based on the frequency or amplitude modulation of tones.

OBJECTIVE:

The aim of this study was to determine the sensitivity and specificity of auditory steady‐state response testing in detecting lesions and dysfunctions of the central auditory nervous system.

METHODS:

Seventy volunteers were divided into three groups: those with normal hearing; those with mesial temporal sclerosis; and those with central auditory processing disorder. All subjects underwent auditory steady‐state response testing of both ears at 500 Hz and 2000 Hz (frequency modulation, 46 Hz). The difference between auditory steady‐state response‐estimated thresholds and behavioral thresholds (audiometric evaluation) was calculated.

RESULTS:

Estimated thresholds were significantly higher in the mesial temporal sclerosis group than in the normal and central auditory processing disorder groups. In addition, the difference between auditory steady‐state response‐estimated and behavioral thresholds was greatest in the mesial temporal sclerosis group when compared to the normal group than in the central auditory processing disorder group compared to the normal group.

DISCUSSION:

Research focusing on central auditory nervous system (CANS) lesions has shown that individuals with CANS lesions present a greater difference between ASSR‐estimated thresholds and actual behavioral thresholds; ASSR‐estimated thresholds being significantly worse than behavioral thresholds in subjects with CANS insults. This is most likely because the disorder prevents the transmission of the sound stimulus from being in phase with the received stimulus, resulting in asynchronous transmitter release. Another possible cause of the greater difference between the ASSR‐estimated thresholds and the behavioral thresholds is impaired temporal resolution.

CONCLUSIONS:

The overall sensitivity of auditory steady‐state response testing was lower than its overall specificity. Although the overall specificity was high, it was lower in the central auditory processing disorder group than in the mesial temporal sclerosis group. Overall sensitivity was also lower in the central auditory processing disorder group than in the mesial temporal sclerosis group.  相似文献   

6.

Background

Online hearing tests conducted in home settings on a personal computer (PC) require prior calibration. Biological calibration consists of approximating the reference sound level via the hearing threshold of a person with normal hearing.

Objective

The objective of this study was to identify the error of the proposed methods of biological calibration, their duration, and the subjective difficulty in conducting these tests via PC.

Methods

Seven methods have been proposed for measuring the calibration coefficients. All measurements were performed in reference to the hearing threshold of a normal-hearing person. Three methods were proposed for determining the reference sound level on the basis of these calibration coefficients. Methods were compared for the estimated error, duration, and difficulty of the calibration. Web-based self-assessed measurements of the calibration coefficients were carried out in 3 series: (1) at a otolaryngology clinic, (2) at the participant’s home, and (3) again at the clinic. Additionally, in series 1 and 3, pure-tone audiometry was conducted and series 3 was followed by an offline questionnaire concerning the difficulty of the calibration. Participants were recruited offline from coworkers of the Department and Clinic of Otolaryngology, Wroclaw Medical University, Poland.

Results

All 25 participants, aged 22-35 years (median 27) completed all tests and filled in the questionnaire. The smallest standard deviation of the calibration coefficient in the test-retest measurement was obtained at the level of 3.87 dB (95% CI 3.52-4.29) for the modulated signal presented in accordance with the rules of Bekesy’s audiometry. The method is characterized by moderate duration time and a relatively simple procedure. The simplest and shortest method was the method of self-adjustment of the sound volume to the barely audible level. In the test-retest measurement, the deviation of this method equaled 4.97 dB (95% CI 4.53-5.51). Among methods determining the reference sound level, the levels determined independently for each frequency revealed the smallest error. The estimated standard deviations of the difference in the hearing threshold between the examination conducted on a biologically calibrated PC and pure-tone audiometry varied from 7.27 dB (95% CI 6.71-7.93) to 10.38 dB (95% CI 9.11-12.03), depending on the calibration method.

Conclusions

In this study, an analysis of biological calibration was performed and the presented results included calibration error, calibration time, and calibration difficulty. These values determine potential applications of Web-based hearing tests conducted in home settings and are decisive factors when selecting the calibration method. If there are no substantial time limitations, it is advisable to use Bekesy method and determine the reference sound level independently at each frequency because this approach is characterized by the lowest error.  相似文献   

7.

OBJECTIVE:

The audibility thresholds for the sound frequency of 137 upward- and downward-sloping audiograms showing sensorineural hearing loss were selected and analyzed in conjunction with speech recognition thresholds obtained from individuals seen at a public otolaryngology clinic to determine which frequencies in slope audiograms best represent speech recognition thresholds.

METHOD:

The linear regression model and mean square error were used to determine the associations between the threshold values.

RESULT:

The mean square error identified larger errors when using thresholds of 500, 1000, and 2000 Hz than when using audibility thresholds of 500, 1000, 2000, and 4000 Hz. The linear regression model showed a higher correlation (91%) between the audiogram thresholds for frequencies of 500, 1000, 2000, and 4000 Hz than for the frequencies of 500, 1000, and 2000 Hz (88%).

CONCLUSION:

Frequencies of 500, 1000, 2000, and 4000 Hz were the most significant in predicting the speech recognition threshold.  相似文献   

8.

INTRODUCTION

Individuals with sensorineural hearing loss are often able to regain some lost auditory function with the help of hearing aids. However, hearing aids are not able to overcome auditory distortions such as impaired frequency resolution and speech understanding in noisy environments. The coexistence of peripheral hearing loss and a central auditory deficit may contribute to patient dissatisfaction with amplification, even when audiological tests indicate nearly normal hearing thresholds.

OBJECTIVE

This study was designed to validate the effects of a formal auditory training program in adult hearing aid users with mild to moderate sensorineural hearing loss.

METHODS

Fourteen bilateral hearing aid users were divided into two groups: seven who received auditory training and seven who did not. The training program was designed to improve auditory closure, figure-to-ground for verbal and nonverbal sounds and temporal processing (frequency and duration of sounds). Pre- and post-training evaluations included measuring electrophysiological and behavioral auditory processing and administration of the Abbreviated Profile of Hearing Aid Benefit (APHAB) self-report scale.

RESULTS

The post-training evaluation of the experimental group demonstrated a statistically significant reduction in P3 latency, improved performance in some of the behavioral auditory processing tests and higher hearing aid benefit in noisy situations (p-value < 0,05). No changes were noted for the control group (p-value <0,05).

CONCLUSION

The results demonstrated that auditory training in adult hearing aid users can lead to a reduction in P3 latency, improvements in sound localization, memory for nonverbal sounds in sequence, auditory closure, figure-to-ground for verbal sounds and greater benefits in reverberant and noisy environments.  相似文献   

9.

Purpose

Tinnitus is a very common symptom of vestibular schwannoma, present in 45 to 80% of patients. We evaluated changes in tinnitus after translabyrinthine microsurgery (TLM) or gamma knife radiosurgery (GKS).

Materials and Methods

Among 78 patients with vestibular schwannoma who underwent TLM or GKS at Severance Hospital from 2009-2012, 46 patients with pre- or postoperative tinnitus who agreed to participate were enrolled. Pure tone audiometry, tinnitus handicap inventory (THI), visual analogue scale (VAS) scores for loudness, awareness, and annoyance were measured before and after treatment. Changes of THI and VAS were analysed and compared according to treatment modality, tumour volume, and preoperative residual hearing.

Results

In the TLM group (n=27), vestibulocochlear nerves were definitely cut. There was a higher rate of tinnitus improvement in TLM group (52%) than GKS group (16%, p=0.016). The GKS group had a significantly higher rate of tinnitus worsening (74%) than TLM group (11%, p<0.001). Mean scores of THI and VAS scores significantly decreased in the TLM group in contrast to significant increases in the GKS group. Tumor volume and preoperative hearing did not affect the changes in THI or VAS.

Conclusion

GKS can save vestibulocochlear nerve continuity but may damage the cochlea, cochlear nerve and can cause worsening tinnitus. In cases where hearing preservation is not intended, microsurgery with vestibulocochlear neurectomy during tumor removal can sometimes relieve or prevent tinnitus.  相似文献   

10.
11.

Background

Hearing impairment is most accurately measured by a clinical pure-tone audiogram. This method is not suitable for large-scale, population-based epidemiological studies as it requires that study participants visit a clinic with trained personnel. An alternative approach to measuring hearing ability is self-estimation through questionnaires, but the correlation to clinical audiometric tests varies.

Objective

To evaluate an Internet-based hearing test pilot compared to a question about self-estimated hearing and the feasibility of using an Internet-based hearing test and an Internet-based questionnaire in a population of 560 members of the Swedish Hunters’ Association in the age group 20-60 years.

Methods

An invitation was mailed to the participants in March 2007 together with the URL to the study Web site, a personal username, and a password. The Web site included the questionnaire, the hearing test, and instructions for participating in the study. The hearing test resembles a clinical audiogram presenting 6 tones between 500 and 8000 Hz. Tones are presented between 0 and 60 dB, and the participant responds to the tones by pressing the space bar. The hearing test requires headphones and is based on JAVA programming. Before the participant can start the hearing test, it has to be calibrated against a reference person with good hearing between 15 and 35 years of age.

Results

After 5 months, 162 out of 560 (29%) had answered the questionnaire, out of which 88 (16%) had completed the hearing test. Those who actively declined participation numbered 230 out of 560 (41%). After removing duplicates and hearing tests calibrated by unreliable reference data, 61 hearing tests remained for analysis. The prevalence of hearing impairment from the Internet-based hearing test was 20% (12 out of 61), compared to 52% (32 out of 61) from the self-estimated question. Those who completed the hearing test were older than the non-participants, and more had headphones (P = .003) and the correct version of the JAVA program (P = .007) than those who only answered the questionnaire.

Conclusions

Though an Internet-based hearing test cannot replace a clinical pure-tone audiogram conducted by a trained audiologist, it is a valid and useful screening tool for hearing ability in a large population carried out at a low cost.  相似文献   

12.

Background

To date, no therapeutic option has been established for sudden deafness refractory to systemic corticosteroids. This study aimed to examine the efficacy and safety of topical insulin-like growth factor-1 (IGF-1) therapy in comparison to intratympanic corticosteroid therapy.

Methods

We randomly assigned patients with sudden deafness refractory to systemic corticosteroids to receive either gelatin hydrogels impregnated with IGF-1 in the middle ear (62 patients) or four intratympanic injections with dexamethasone (Dex; 58 patients). The primary outcome was the proportion of patients showing hearing improvement (10 decibels or greater in pure-tone average hearing thresholds) 8?weeks after treatment. The secondary outcomes included the change in pure-tone average hearing thresholds over time and the incidence of adverse events.

Results

In the IGF-1 group, 66.7% (95% confidence interval [CI], 52.9-78.6%) of the patients showed hearing improvement compared to 53.6% (95% CI, 39.7-67.0%) of the patients in the Dex group (P?=?0.109). The difference in changes in pure-tone average hearing thresholds over time between the two treatments was statistically significant (P?=?0.003). No serious adverse events were observed in either treatment group. Tympanic membrane perforation did not persist in any patient in the IGF-1 group, but did persist in 15.5% (95% CI, 7.3-27.4%) of the patients in the Dex group (P?=?0.001).

Conclusions

The positive effect of topical IGF-1 application on hearing levels and its favorable safety profile suggest utility for topical IGF-1 therapy in patients with sudden deafness.

Trial registration

UMIN Clinical Trials Registry Number UMIN000004366, October 30th, 2010.
  相似文献   

13.

Background

Hearing impairment is a common problem in patients with mucopolysaccharidosis IV (MPS IV) throughout their life. Many of the adult patients with MPS IV exhibit permanent or severe hearing loss. However, there has been no systematic review of detailed audiological test results in MPS IV.

Materials and methods

Fourteen individuals with MPS IV (13 MPS IVA and 1 MPS IVB; aged between 12 and 38?years old) participated in the current study. We obtained auditory neurophysiological responses (auditory brainstem responses and otoacoustic emissions test) in addition to pure-tone audiometry and middle ear function tests (tympanometry and acoustic reflexes).

Results

The results indicated various levels and types of hearing loss with abnormal neurophysiological responses even in those patients with MPS IVA with normal pure tone thresholds. We also found a strong relationship between height (short stature is an indicator of skeletal severity) and hearing sensitivity as well as a strong relationship between height and outer hair cell function in the inner ear (measured by otoacoustic emissions) among MPS IVA patients.

Conclusion

The strong correlation between reduced height and hearing loss indicates that patients with severe skeletal dysplasia may be at higher risk of developing more severe hearing loss. More importantly, the spectrum of hearing disorders indicates that MPS IV patients should have annual neurophysiological hearing tests in addition to audiometric testing from an early age regardless of their skeletal severity to more carefully monitor disease progression.  相似文献   

14.

Background

In the context of universal access to prevention, treatment, care and support, each country has to ensure that 80% of women and children in need have access to PMTCT interventions.

Objective

To assess the PMTCT program achievement in Ouagadougou, the capital city of Burkina Faso.

Methods

Between August and October 2008, a cross sectional study was carried out in the five health districts of the Centre Health Region. We reviewed weekly statistics from all health care centres (HCC) to compute the coverage of PMTCT program. In 38 HCC with functional PMTCT program, we extracted data of interest from HCC registers and made direct observations of PMTCT services.

Results

The PMTCT program was implemented in 49% of HCC (target for the national program: 70%). Fifteen to 31% of these centers were often in shortage for PMTCT consumables. Patients'' privacy was not observed in 67% of Voluntary Counselling & HIV Testing wards. Care providers were not qualified enough to deliver PMTCT services. Vitamin A supplementation was not implemented. None of the facilities offered the whole package of PMTCT program interventions. HCC providing HIV testing in labour or in postnatal ward were consistently lacking. Only 86% of antenatal care new attendants benefited from pre-test counselling; 2.4% of pretested women were HIV-positive and 39% of positive mothers received antiretroviral prophylaxis.

Conclusion

Coverage and quality of PMTCT programme in the Centre Health Region in Burkina Faso are still limited. Particular support is needed for training, supervision and infrastructures upgrading.  相似文献   

15.

Purpose

Hearing loss can lead to a number of disabilities and can reduce quality of life. Noise-induced hearing losses have become more common among adolescents due to increased exposure to personal music players. We, therefore, investigated the use of personal music player among Korean adolescents and the relationship between hearing threshold and usage pattern of portable music players.

Materials and Methods

A total of 490 adolescents were interviewed personally regarding their use of portable music players, including the time and type of player and the type of headphone used. Pure tone audiometry was performed in each subject.

Results

Of the 490 subjects, 462 (94.3%) used personal music players and most of them have used the personal music player for 1-3 hours per day during 1-3 years. The most common type of portable music player was the MP3 player, and the most common type of headphone was the earphone (insert type). Significant elevations of hearing threshold were observed in males, in adolescents who had used portable music players for over 5 years, for those over 15 years in cumulative period and in those who had used earphones.

Conclusion

Portable music players can have a deleterious effect on hearing threshold in adolescents. To preserve hearing, adolescents should avoid using portable music players for long periods of time and should avoid using earphones.  相似文献   

16.
17.

Background

Low health literacy is associated with poorer health and higher mortality. Complex health materials are a barrier to health.

Aim

To assess the literacy and numeracy skills required to understand and use commonly used English health information materials, and to describe population skills in relation to these.

Design and setting

An English observational study comparing health materials with national working-age population skills.

Method

Health materials were sampled using a health literacy framework. Competency thresholds to understand and use the materials were identified. The proportion of the population above and below these thresholds, and the sociodemographic variables associated with a greater risk of being below the thresholds, were described.

Results

Sixty-four health materials were sampled. Two competency thresholds were identified: text (literacy) only, and text + numeracy; 2515/5795 participants (43%) were below the text-only threshold, while 2905/4767 (61%) were below the text + numeracy threshold. Univariable analyses of social determinants of health showed that those groups more at risk of socioeconomic deprivation had higher odds of being below the health literacy competency threshold than those at lower risk of deprivation. Multivariable analysis resulted in some variables becoming non-significant or reduced in effect.

Conclusion

Levels of low health literacy mirror those found in other industrialised countries, with a mismatch between the complexity of health materials and the skills of the English adult working-age population. Those most in need of health information have the least access to it. Efficacious strategies are building population skills, improving health professionals’ communication, and improving written health information.  相似文献   

18.
19.

OBJECTIVE:

The aim of this study was to characterize the epidemiological profile of the population attending primary health care units in the western region of the city of São Paulo, Brazil, highlighting referred speech-language and hearing complaints.

METHOD:

This investigation was a cross-sectional observational study conducted in primary health care units. Household surveys were conducted and information was obtained from approximately 2602 individuals, including (but not limited to) data related to education, family income, health issues, access to public services and access to health services. The speech-language and hearing complaints were identified from specific questions.

RESULTS:

Our results revealed that the populations participating in the survey were heterogeneous in terms of their demographic and economic characteristics. The prevalence of referred speech-language and hearing complaints in this population was 10%, and only half the users of the public health system in the studied region who had complaints were monitored or received specific treatment.

CONCLUSIONS:

The results demonstrate the importance of using population surveys to identify speech-language and hearing complaints at the level of primary health care. Moreover, these findings highlight the need to reorganize the speech-language pathology and audiology service in the western region of São Paulo, as well as the need to improve the Family Health Strategy in areas that do not have a complete coverage, in order to expand and improve the territorial diagnostics and the speech-language pathology and audiology actions related to the prevention, identification, and rehabilitation of human communication disorders.  相似文献   