首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Permanent Pacing in Patients with Univentricular Heart   总被引:2,自引:0,他引:2  
Patients with one of several varieties of malformation designated as "univentricular hearts" may be especially challenging when permanent pacing is required. Our objective was to review our experience in this subset of patients that had undergone permanent pacing and thus determine the optimal approach. A retrospective chart review was done of 32 patients with some variety of "univentricular" malformation who had required permanent pacing at our institution. Although technically challenging, permanent pacing in this group of patients can be successful through several approaches. The various approaches, as well as consideration of the differences that exist between patients undergoing septation and those undergoing a Fontan procedure are discussed. Although long-term permanent pacing is possible in this group of patients, before pacing begins, a thorough understanding of the anatomy and prior surgical procedures is necessary. Use of a combined atrial transvenous and ventricular epicardial pacing system may work well for some patients. With the development of newer and more reliable coronary sinus leads, dual chamber transvenous pacing with ventricular stimulation via the coronary sinus could become the approach of choice in some patients with "univentricular hearts."  相似文献   

2.
To evaluate the feasibility of chronic atrial pacing (AAI) in sick sinus syndrome (SSS), 22 patients (pts) with bradytachycardia syndrome (BTS) and 17 patients with only bradyarrhythmias (BA) were studied on the incidence of supraventricular tachycardias (SVT) and occurring AV block. A scoring system based on symptoms of SVT was developed (grade 0–5). All patients had proven normal AV conduction before PM implantation. In the BTS-group, nine patients (41%) had symptomatic SVT at the end of follow-up (mean 53 months), despite drug therapy. These patients had a high SVT score on entry (mean 3.2). High degree AV block occurred in three patients. Although in the BA-group SVT arose in six patients (35%), there was only one symptomatic patient at the end of follow-up (mean 36 months). In this group, only one patient developed high degree AV block. Atrial stimulation should be considered as a reliable therapy in patients with SSS and low SVT score before PM implantation when normal AV conduction is present.  相似文献   

3.
The physiological efficacy of single chamber, rate responsive ventricular pacing (VVIR) is unknown for symptomatic patients following the Fontan procedure for univentricular hearts. A total of six postoperative children, ages 6–21 years (mean 13), with symptomatic bradycardia requiring pacing therapy, underwent comparative treadmill exercise testing in randomized fixed rate (VVI) and VVIR pacing modes. In all instances, implanted activity pulse generators (Medtronic Model 8403) were programmed to identical age-appropriate low paced rates during WI and VVIR modes with the upper rate response at 150 ppm. All studies were performed at least 2 weeks apart. Physiological values of heart rate, blood pressure, work rate (watts), oxygen comsumption (VO2), carbon dioxide production (VCO2), and respiratory exchange ratio (RER) were monitored continuously during each test using a 1 minute incremental treadmill protocol. Ventilatory anaerobic threshold (VAT) was calculated from VO2, VCO2, and minute ventilation. The results demonstrated that although there was a significant increase in paced heart rate per minute throughout exercise (P < 0.01) with VVIR pacing, maximum watts, VO2, and VAT remained unchanged. These findings indicate that in spite of an improved chronotropic response to exercise, children with Univentricular hearts following the Fontan procedure continue to demonstrate altered hemodynamics which negate potential benefits of VVIR pacing.  相似文献   

4.
本文报告35例不明原因窦缓者的食道调搏电生理检查结果,着重对反映窦房结功能的心脏固有心率。窦房结恢复时间、校正窦房结恢复时间、窦房传导时间进行分析,并揭示了其相关性。  相似文献   

5.
A consecutive series of 66 patients (males = 32; mean age +/- SD = 71 +/- 9 years) given atrial inhibited pacemakers for sick sinus nodes were followed to study the incidence of lead failures, chronic atrial tachyarrhythmias, and atrioventricular conduction disturbances. The need for rate responsive pacing was also assessed. Pre and postoperative investigation could include carotid sinus massage, Holter monitoring, exercise testing, and invasive electrophysiology. The mean follow-up time +/- SD was 32 +/- 29 months (median = 26 months). Three patients (5%) had their pacemakers replaced due to lead failures (loss of sensing = 2; exit block = 1). Two pacemakers (3%) were replaced after 5 and 22 months due to atrial fibrillation. Four patients (6%) received new pacemakers because of development of second-degree or complete atrioventricular block after 1, 6, 12, and 31 months, respectively. During exercise, most patients (76%) responded with an increase in sinus rate at least as marked as that achievable with the currently available rate responsive pacemakers. Assuming careful patient selection, atrial inhibited pacing is well suited for many patients with sinus node dysfunction and preserved atrioventricular conduction. There is a limited need for rate responsive pacemakers in these patients.  相似文献   

6.
SPITZER, S.G., et al .: Pacing of the Atria in Sick Sinus Syndrome Trial: Preventive Strategies for Atrial Fibrillation. This study examines the effects of various atrial lead positions in physiological pacing on the incidence of AF in patients with sick sinus syndrome. The lead is implanted in the RA free wall, in the RA appendage, near the coronary sinus ostium (CSO) or, in dual site RA pacing, in the appendage and the CSO. Since CSO and dual site right atrial pacing aim at modifying the pathological substrate, pacing of two-thirds of all cardiac cycles is attempted by adapting the basic rate and the rate response option. The results of this study are expected to assist in the development of guidelines for the placement of atrial pacing leads in sick sinus syndrome. (PACE 2003; 26[Pt. II]:268–271)  相似文献   

7.
The right atrial appendage is frequently amputated at the time of open heart surgery. In this study we report implantation and chronic follow-up pacing data on 17 patients in whom either actively fixated screw-in leads or passively fixated tined "J" leads were implanted into the trabeculae at the base of the atrial appendage. Chronic follow-up demonstrated excellent chronic pacing thresholds and atrial sensitivity thresholds in those patients in whom these measurements could be made. It is therefore concluded that satisfactory atrial pacing can be achieved in patients who have previously undergone amputation of the atrial appendage during open heart surgery.  相似文献   

8.
Following the Fontan operation for definitive palliation of the univentricular heart, sinus node dysfunction, and/or atrioventricular block requiring pacemaker therapy is common. In previous studies ventricular rate responsive pacing (VVI, R) resulted in improved exercise performance over VVI pacing in anatomically normal hearts with either sinus node disease or atrioventricular block. In this study, the usefulness of both VVI, R and DDD, R pacing are evaluated in the postoperative univentricular heart following the Fontan operation. Eight postoperative Fontan patients with sinus node disease or atrioventricular block underwent exercise testing using a treadmill protocol. Six patients had single chamber ventricular pacemakers and two patients had dual chambered rate responsive pacemakers. Median age at exercise testing was 14 years. Patients were tested in the VVI, VVI, R, and DDD, R modes acting as their own controls. Heart rate, work rate, oxygen consumption, and respiratory exchange ratio were monitored continuously. Heart rate was significantly increased in the rate responsive modes compared to the VVI mode. In spite of the significant increase in heart rate, there was no change in maximal work rate or oxygen consumption. There was also no significant change in oxygen consumption at ventilatory anaerobic threshold. From these data we would conclude that VVI, R pacing in postoperative univentricular hearts does not result in improved exercise performance and that further study with DDD, R pacing is needed to determine its usefulness in this group of patients.  相似文献   

9.
目的:观察心室起搏管理(managed ventricular pacing,MVP)对病态窦房结综合征(sick sinus syndrome,SSS)患者心功能的影响.方法:42例植入具有MVP功能的双腔起搏器(Medtronic Adapta ADD01/ADDR01/ADDRL1)的SSS患者,先以双腔起搏(DDD/R)模式工作6个月,再程控为MVP模式工作6个月,统计两种模式下右心室起搏比例,并比较两种模式下患者心功能的变化.结果:在DDD/R模式下,平均右心室心尖部起搏比例达43.6%,左心室射血分数(left ventricular ejection fraction,LVEF)从(56.5±2.6)%下降至(54.1±3.0)%(P=0.001),左心室舒张末期直径(left ventricular end-diastolic diameter,LVEDD)从(49.6±2.6)mm升高至(51.4±2.4)mm(P=0.002),B型利钠肽(B-type natriuretic peptide,BNP)从(77.0±16.2) pg/mL升高至(87.2±16.4) pg/mL(P=0.032).在MVP模式下,平均右心室心尖部起搏比例仅为1.8%,LVEF从(54.1±3.0)%上升至(55.4±1.4)%(P=0.042),LVEDD从(51.4±2.4)mm下降至(50.2±2.0)mm(P=0.016),BNP从(87.2±16.4) pg/mL下降至(86.5±14.9) pg/mL(P=0.852).另外,DDD/R模式下有4例患者发生阵发性心房颤动,而MVP模式下仅1例发生阵发性心房颤动,但差异无统计学意义(P=0.180).结论:与DDD/R模式比较,MVP模式能显著减少右心室起搏比例,且对心功能有较好的保护作用.  相似文献   

10.
Rate Adaptive Atrial Pacing in the Bradycardia Tachycardia Syndrome   总被引:1,自引:0,他引:1  
In 42 patients (26 men, 16 women; mean age 69 ± 10 years), who were paced and medicated with antiarrhythmic drugs for the bradycardia tachycardia syndrome, chronotropic response and AV conduction with rapid atrial pacing during exercise were studied. Patients were included if they had no second- or third-degree AV block, no complete bundle branch or bifascicular block, and a PQ interval ≤ 240 ms during sinus rhythm at rest. The interval between the atrial spike and the following Q wave (SQ) was measured in the supine position at rest with an AAI pacing rate of 5 beats/min above the sinus rate (SQ-R+5), and at the end of exercise with 110 beats/min (SQ-E110). Bicycle ergometry was performed using the Chronotropic Assessment Exercise Protocol with the pacemakers being programmed to AAI with a fixed rate of 60 beats/min. Chronotropic incompetence was defined as peak exercise heart rate: (1) < 100 beats/min; (2) < 75% of the maximum predicted heart rate; or (3) the heart rate at half the maximum workload < 60 + 2 beats/min per mL O2/kg per minute (calculated O2 consumption). During exercise, one patient developed atrial fibrillation. Chronotropic incompetence was present in 71 % (29/41) of the patients according to definition 2, and in 76% (31/41) according to definition 1 or 3. Ten out of 41 patients (24%) exhibited a second-degree AV block with atrial pacing at 110 beats/min at the end of exercise. Only 9 out of the remaining 31 patients (29%) showed a physiological adaptation of the SQ-E110, and 21 patients (68%) exhibited a paradoxical increase of the SQ interval with rapid atrial pacing at the end of exercise as compared to the SQ-R+5. These observations indicate that the pacing system to be used in most patients paced and medicated for the bradycardia tachycardia syndrome should be dual chamber, and the option of rate adaptation should be considered.  相似文献   

11.
To evaluate the feasibility of intrauterine transvenous cardiac pacing, the right ventricular output was measured during pacing in six fetal lambs. Under maternal anesthesia, the uterus was opened, and, under local anesthesia, the pacing lead (Medtronic Capsure SP4023) was inserted via the fetal left internal jugular vein. Right ventricular output was estimated using an Aloka SSD-730 ultrasound device, and tricuspid valve regurgitation was evaluated with an Aloka SSD-880 using the transuterine approach. The ultrasonic right ventricular cardiac output was measured under three different conditions: (1) with the tip of the pacing lead in the superior vena cava (control); (2) with the tip of the pacing lead in the right ventricle; and (3) with pacing at 200 beats/min. The right ventricular output decreased when the pacing lead was inserted into the right ventricle, as well as during pacing at 200 beats/min ([1] = 107 ± 13.2 ml/kg per min; [2] = 73.8 ± 17. 5 ml/kg per min; and [3] = 78.3 ± 23.6 ml/kg per min), Tricuspid regurgitation did not change under any of the conditions tested. Intrauterine transvenous cardiac pacing was successfully achieved. Insertion of the pacing lead into the right ventricle decreased the ventricular output without increasing tricuspid valve regurgitation.  相似文献   

12.
In this study, we used Holter pacemakers in a group of 13 patients affected by severe carotid sinus syndrome in order to evaluate its evolution. All the patients had one to three syncopal episodes and frequent other symptoms such as fainting, dizziness, lightheadedness and pre-syncope interferring with their daily activity so that pacemaker therapy was considered necessary. Patient selection criteria were: presence of the isolated cardioinhibitory type, absence of associated sinus dysfunction and absence of symptomatic WI pacemaker effect. All the patients received a Micropacer 1 device; among special functions, bradycardia events counter was activated and programmed so that each sequence of three consecutives beats at a cycle length 1.5 sec (i.e., 4.5 sec total interval) could he recognized and stored in its memory. The follow-up lasted 13±7 months. Brady events occurred in eight out of 13 patients (62%), during this period. Syncope and major symptoms disappeared in ail the patients; mild dizziness recurred rarely in two patients and were not linked to brady-events recording. In conclusion, disappearance of severe symptoms observed after pacemaker implant in cardioinhibitory carotid sinus syndrome seems to depend from pacing therapy, in most cases, yet from the benign natural course of the disease in some other cases.  相似文献   

13.
A 17-year-old boy with severe sick sinus bradycardia had a doubly redundant pacemaker inserted. With two separate ventricular leads inserted by the epicardial route, the pacemaker is able to compensate for a lead that has developed high threshold by activation of an alternate lead. The two pacing channels of the pulse generator can be programmed independently of one another. In addition, there is a back-up pacing circuit separate from the two primary channels. The pacer can be used with both channels active for continuous automatic redundancy for safety, or with one channel active and the other in reserve.  相似文献   

14.
Atrial and dual-chamber pacemakers may be associated with reduced morbidity in patients with the sick sinus syndrome (SSS). In some patients, however, subsequent development of chronic atrial fibrillation or atrial lead failure make long-term pacing in the atrium not feasible. We analyzed the incidence and predictors of loss of atrial pacing in 395 consecutive patients with SSS (376 with dual-chamber pacemakers and 19 with single-chamber atrial pacemakers). None of them was in established atrial fibrillation at time of implant. Patients were followed-up for 55 ± 35 months. Actuarial survival of effective atrial pacing was 92.5% at 1 year, 85% at 5 years, and 76.5% at 10 years. Overall, 60 patients lost atrial pacing. The most frequent cause was the development of chronic atrial fibrillation (53 patients). By multivariate analysis (Cox proportional-hazards model), independent predictors of Joss of pacing in the atrium were preimplant episodes of paroxysmal atrial fibrillation (PAF) lasting more than 1 hour (P < 0.001; hazard ratio (HR) = 4.3); prior history of PAF for more than 5 years (P < 0.001; HR = 2.67; and endocardial P wave < 2 mV (P = 0.014; HR = 1.96). In a subgroup of patients (n = 187) who had echocardiograms, a left atrium > 50 mm was also an independent predictor of loss of atrial pacing (P = 0.028; HR = 2.28). Conclusions: 1) most patients with SSS can maintain long-term atrial pacing; 2) loss of pacing in the atrium is related to the previous history of PAF, left atrial enlargement, and low amplitude of the endocardial P wave at implant; and 3) patients with these risks variables are less than ideal candidates for atrial pacing modes. In them, the implant of DDDR units might be indicated, to provide wide flexibility in case reprogramming to a ventricular pacing mode is required.  相似文献   

15.
The purpose of this study was to find out whether transesophageal pacing could be utilized for assessment of sinus node function in patients with sick sinus syndrome (SSS). In 17 patients with SSS (study group) we compared the results of sinus node tests obtained both in the basal state and after pharmacological autonomic blockade by endocavitary stimulation and, 24 hours later, by transesophageal pacing. In another group of 17 patients with SSS (control group), we compared the results obtained by two endocavitary studies. In "study group", sinus cycle length (SCL) and corrected sinus node recovery time (CSRT) did not show significant differences between the two studies both in the basal state and after autonomic blockade, whereas sinoatrial conduction time (SACT) was more prolonged during esophageal pacing (P less than 0.01). In "control group", sinus node measures did not show significant differences between the two studies. In the "study group," the following coefficients of correlation were obtained in the basal state; SCL, r = 0.65, CSRT, r = 0.57, SACT, r = 0.52 and after autonomic blockade: SCL, r = 0.95, CSRT, r = 0.62 and SACT, r = 0.53. In the basal state, the correlation for SCL and CSRT between the two studies was lower in the "study group" than in the "control group" (P less than 0.05), whereas after autonomic blockade the correlation for sinus node measures did not show significant differences between the two groups of patients. These data suggest that transesophageal study influences the autonomic tone regulating the sinus node; however, it is not responsible for important variations in sinus node measures.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

16.
The most "natural" rate adaptive pacemaker is VDD for patients with AV block. Nothing equivalent exists for patients with sick sinus syndrome (SSS). Even if they are paced in the AAI mode, the AV synchrony is often lost under exercise if nodal rhythms develop which cause the atria to contract against closed valves by retrograde conduction. We tried to develop a concept of rate adaptive pacing which is applicable in SSS patients by guaranteeing AV synchrony. It is known that AV delay shortens with increasing rate under exercise in normal subjects. Three AAI paced patients were evaluated to find out whether a similar correlation is valid between exercise and AV delay with constant rate. A nonconventional ECG was registered during the whole procedure by using an analog tape recorder. The pacing rate was changed with and without exercise on a bicycle to determine its influence on AV delay and by calculating the AV delay averaged over the last 8 beats. In all three patients a reproducible correlation existed between exercise and shortening of the AV delay. This effect was already detectable after 10 s. Increasing the pacing rate above "physiological" rates caused prolongation of the AV delay (over-stimulation phenomenon). We, therefore, concluded that measuring the AV delay in atrial paced patients with SSS by means of a ventricular electrode can be used as a fast parameter for rate adaptive pacing with AV synchrony. The "over-stimulation" phenomenon can additionally be utilized for controlling "physiological" rates depending on individual needs.  相似文献   

17.
The number of patients receiving cardiac pacemakers for sick sinus syndrome (SSS) has increased considerably in recent years. The literature has suggested that patients with sick sinus syndrome have a shorter life expectancy with pacemaker therapy than patients with total heart block or atrial fibrillation. We studied the survival rate of 1,049 patients with complete heart block, 592 with sick sinus syndrome and 447 with atrial fibrillation. After 10 years we found a survival rate of 54.5% for patients paced for SSS, 34.4% for those with complete heart block, and 24.7% for those with atrial fibrillation (statistical significance: SSS--heart block: p less than 0.05; SSS--atrial fibrillation: p less than 0.01; heart block--atrial fibrillation: NS). Considering the calculated survival rates of a comparable normal population (i.e., 56.5%; 41.2%; 47.8%), the differences in survival expectancy are even more pronounced (SSS-normal: NS; heart block-normal p less than 0.05; atrial fibrillation-normal: p less than 0.05). For patients with sick sinus syndrome, the life expectancy parallels that of the general population, while that of patients with complete heart block or atrial fibrillation have a life expectancy that is considerably lower.  相似文献   

18.
A marked increase of chronic atrial pacing threshold resulting in loss of atrial capture, induced by propafenone, is reported in a patient with bradycardia-tachycardia syndrome. After atrial pacemaker implant, the atrial threshold had been measured repeatedly noninvasively and shown to be stable. The threshold rise and loss of atrial capture occurred after 7 days of treatment with propafenone at the dosage of 450 mg daily; drug withdrawal resulted in resumption of atrial capture and a return to prior pacing thresholds.  相似文献   

19.
Sinus arrest occurred in a patient with acute diaphragmatic myocardial infarction associated with right ventricular infarction. Cardiac output fell dramatically despite maintenance of a junctional rate of 72. Ventricular pacing at rate 82 and dopamine administration resulted in only slight hemodynamic improvement. Atrial pacing at rate 84 restored normal cardiac output until resumption of sinus node activity. These results suggest that atrial contraction is important for the maintenance of ventricular function in some patients with acute infarction, and may be of particular importance in the presence of right ventricular infarction. Temporary atrial or atrioventricular sequential pacing may be of great hemodynamic benefit in selected patients with conduction defects complicating myocardial infarction.  相似文献   

20.
An electrode for transvenous permanent ventricular pacing equipped with a supermagnet was implanted in six dogs in the apex of the right ventricle for several weeks. As no signs of myocardial perforation occurred, the device which consists of the magnetic tip lead and an external supermagnet applied to the precordial region of the chest wall was implanted in 14 patients. The lead was introduced through the right cephalic vein in 12 patients and through the right external jugular vein in the remaining 2 patients. Threshold values were measured twice a day in 12 patients who received a Siemens-Elema Vario pacemaker 629. The average peak threshold was reached on the 11th day after implantation. No pacing failure or other signs of acute dislodgement of leads occurred during the first 30 days.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号