首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Ulnar collateral ligament (UCL) tears can occur from trauma or chronic overuse, and the treatment depends on the type of sport the patient plays and the severity of symptoms. Overuse UCL injuries are most commonly due to micro-trauma in overhead athletes such as baseball players, softball players, and tennis players. Acute complete UCL tears in athletes due to trauma are less common but generally operative treatment is recommended. In gymnastics, elbow dislocations are more common than isolated UCL injuries, and there is sparse literature on the success of non-operative treatment of isolated UCL injuries in this group of athletes. In this case report, we report a high-level competitive gymnast with an UCL tear and a partial tear of the forearm flexor mass, which was confirmed by a thorough careful physical examination and magnetic resonance imaging. The patient was treated non-operatively and successfully returned to gymnastics without symptoms. This case supports the suggestion that UCL tears of the elbow can be treated successfully in some gymnasts without surgery, and that treatment should be individualized in this group of athletes.  相似文献   

2.
Objective  The aim of our study was to determine the role of the operator’s experience in the sonographic evaluation of the painful shoulder and to validate assumptions about its technical performance in routine practice. Materials and methods  Two radiologists, respectively standard and expert sonographic operators, independently and prospectively scanned 65 patients with clinical suspicion of rotator cuff lesion. Magnetic resonance arthrography was the reference standard. Results  The sensitivity of the expert ultrasound operator was 95.3% for full-thickness rotator cuff tears (41/43), 70.6% for partial-thickness tears (12/17), 64.3% for intratendinous tears (9/14), 100% for abnormality of the long head of biceps tendon (seven of seven), 88.9% for supraspinatus tendinosis (16/18), 96.4% for subacromial bursa abnormalities (53/55), and 91.7% for acromioclavicular joint osteoarthritis (33/36). The two sonographic operators were in very good agreement about full-thickness rotator cuff tears (κ = 0.90), supraspinatus tendinosis (κ = 0.80), abnormalities of the long head of biceps tendon (κ = 0.84), subacromial bursa abnormalities (κ = 0.89), and acromioclavicular osteoarthritis (κ = 0.81). The agreement was only moderate for partial-thickness tears (κ = 0.63) and intratendinous tears (κ = 0.57). Conclusions  Our results show that in moderately experienced hands as in experts’ hands, sonography has a low level of interobserver variability for full-thickness rotator cuff tears. Considering partial-thickness and intratendinous rotator cuff tears, our data suggest that interobserver variability is higher.  相似文献   

3.
4.
Objective Ossification/calcification around the medial femoral condyle has been known as Pellegrini–Stieda (PS) disease for almost 100 years. Little attention has been given to magnetic resonance (MR) imaging characteristics. Our purpose is to demonstrate the anatomy in the medial femoral compartment and imaging findings of PS disease, determining the sites and patterns of ossification.Design and patients In a cadaveric study seven specimens were dissected to show the anatomic relations of the tibial collateral ligament (TCL) and the tendon of the ischiocondylar part of the adductor magnus muscle, in the medial femoral epicondyle. In order to determine the nature of ossification/calcification in PS disease, MR imaging and radiographic findings in nine patients were analyzed by two observers with attention to the specific site, shape, and orientation of the ossification and its relationship to the tibial collateral ligament (TCL) and adductor magnus tendon. Available clinical history was recorded. A classification system addressing different sites and patterns of ossification was developed.Results The anatomic study showed that the TCL and the adductor magnus tendon insert at different sites in the medial femoral condyle and there is no continuation; however, some fibers of the posterior bundle of the TCL overlap the anterior aspect of the adductor magnus tendon. The imaging study showed that shape, orientation, and location of the abnormal calcification and ossification were similar on radiographic and MR imaging analysis. Ossification had an inferior orientation in six cases, a superior orientation in two cases, and both in one case. Four patterns of ossification were noted: (I) a beak-like appearance with an inferior orientation and femoral attachment was present in five cases; (II) a drop-like appearance with an inferior orientation, parallel to the femur, was evident in one case; (III) an elongated appearance with a superior orientation, parallel to the femur, was seen in two cases; and (IV) a beak-like appearance with an inferior and superior orientation, attached to the femur, was seen in one case. The ossification was present in the TCL in six cases, in the adductor magnus tendon in two cases, and in both in one case. The coronal plane was best in detecting and categorizing the ossification.Conclusion Our data indicate that ossification in PS disease is not confined to the TCL but may also involve the adductor magnus tendon. In some cases, it can be related to the anatomic proximity (overlap) of the fibers of these two structures. PS disease should not be regarded as synonymous with ossification of the TCL. The ossification may be classified into four types. No clinical differences among these types appear to exist.  相似文献   

5.
6.
The aim of the study was to evaluate the potential of new-generation multi-slice computed tomography (CT) scanner technology for the delineation of coronary artery stents in an ex vivo setting. Nine stents of various diameters (seven stents 3 mm, two stents 2.5 mm) were implanted into the coronary arteries of ex vivo porcine hearts and filled with a mixture of an iodine-containing contrast agent. Specimens were scanned with a 16-slice CT (16SCT) machine; (Somatom Sensation 16, Siemens Medical Solutions), slice thickness 0.75 mm, and a 64-slice CT (64SCT, Somatom Sensation 64), slice-thickness 0.6 mm. Stent diameters as well as contrast densities were measured, on both the 16SCT and 64SCT images. No significant differences of CT densities were observed between the 16SCT and 64SCT images outside the stent lumen: 265±25HU and 254±16HU (P=0.33), respectively. CT densities derived from the 64SCT images and 16SCT images within the stent lumen were 367±36HU versus 402±28HU, P<0.05, respectively. Inner and outer stent diameters as measured from 16SCT and 64SCT images were 2.68±0.08 mm versus 2.81±0.07 mm and 3.29±0.06 mm versus 3.18±0.07 mm (P<0.05), respectively. The new 64SCT scanner proved to be superior in the ex vivo assessment of coronary artery stents to the conventional 16SCT machine. Increased spatial resolution allows for improved assessment of the coronary artery stent lumen.  相似文献   

7.

Purpose

Based on the anatomy of the deep medial collateral ligament (MCL), it was hypothesized that at least part of its cross-sectional insertion area is jeopardized while performing a standard tibial cut in conventional total knee arthroplasty (TKA). The aim of this study was to determine whether it is anatomically possible to preserve the tibial deep MCL insertion during conventional TKA.

Methods

Thirty-three unpaired cadaveric knee specimens were used for this study. Knees with severe varus/valgus deformity or damage to the medial structures of the knee were excluded. In the first part of the study, the dimensions of the tibial insertion of the deep MCL and its relationship to the joint line were recorded. Next, the cross-sectional area of the deep MCL insertion was determined using calibrated digital photographic analysis. In the second part, the effect of a standard 9-mm 3° sloped tibial cut on the structural integrity of the deep MCL cross-sectional insertion area was determined using conventional instrumentation.

Results

The proximal border of the deep MCL insertion site on the tibia was located on average 4.7 ± 1.2 mm distally to the joint line. After performing a standard 9-mm 3° sloped tibial cut, on average 54 % of the deep MCL insertion area was resected. In 29 % of the cases, the deep MCL insertion area was completely excised.

Conclusion

The deep MCL cannot routinely be preserved in conventional TKA. The deep MCL insertion is at risk and may be jeopardized in case of a tibial cut 9 mm below the native joint line. As the deep MCL is a distinct medial stabilizer and plays an important role in rotational stability, this may have implications in future designs of both unicondylar and total knee arthroplasty, but further research is necessary.  相似文献   

8.
9.
10.
The objectives of the present study are to compare "functional length" between the three bundles of the anterior cruciate ligament (ACL) from extension to deep flexion and to perform a sensitivity study on the patterns of "functional length" change due to deviations in insertion site selection. Nine knees of healthy volunteers were examined using a horizontal open magnetic resonance apparatus with the knee at 0 degrees -150 degrees of flexion and created three-dimensional (3D) virtual models of the knee. The femoral and tibial attachment sites of the three ACL bundles were determined, and the distance between the attachment sites was automatically calculated as the "functional length" of each bundle in each position. After changing the attachment sites, computer simulation was performed to investigate in vivo "functional length" changes for the three bundles of the ACL in normal knee kinematics from extension to deep flexion. Three bundles statistically significantly changed in "functional length" during flexion/extension, while they were longest at full extension, and decreased with increasing knee flexion to 100 degrees . They were smallest at flexion of 100 degrees , with increase lengths with flexion deeper than 100 degrees . Deviation of 6 mm of insertion site beyond attachment area caused significant alteration in the pattern of "functional length" change of each bundle, while deviation of 3 mm within attachment area caused no significant difference. The "functional length" of the three ACL bundles was not isometric, not even the antero-medial bundle. The "functional length" might be of major importance in terms of the site of the ACL insertion. The "functional length" of multiple bundles of the ACL and the pattern of their changes are useful for not only graft choice and preparation but also knee angle and initial tension at graft fixation during multiple-bundle ACL reconstruction surgery.  相似文献   

11.
12.
13.
The feasibility of in vitro mature mouse hepatocyte labeling with a novel iron oxide particle was assessed and the ability of 1.5-T magnetic resonance imaging (MRI) to track labeled mouse hepatocytes in syngenic recipient livers following intraportal cell transplantation was tested. Mouse hepatocytes were incubated with anionic iron oxide nanoparticles at various iron concentrations. Cell viability was assessed and iron oxide particle uptake quantified. Labeled hepatocytes were intraportally injected into 20 mice, while unlabeled hepatocytes were injected into two mice. Liver T2 values, spleen-to-muscle relative signal intensity (RI spleen/muscle ), and liver-to-muscle relative signal intensity (RI liver/muscle ) on gradient-echo T2-weighted imaging after injection of either labeled or unlabeled hepatocytes were compared with an ANOVA test followed by Fisher’s a posteriori PLSD test. Livers, spleens and lungs were collected for histological analysis. Iron oxide particle uptake was saturable with a maximum iron content of 20 pg per cell and without viability alteration after 3 days of culture. Following labeled-cell transplantation, recipient livers showed well-defined nodular foci of low signal intensity on MRI—consistent with clusters of labeled hepatocytes on pathological analysis—combined with a significant decrease in both liver T2 values and liver-to-muscle RI liver/muscle (P = 0.01) with minimal T2 values demonstrated 8 days after transplantation. Conventional MRI can demonstrate the presence of transplanted iron-labeled mature hepatocytes in mouse liver.  相似文献   

14.
We report a case of massive pulmonary embolus demonstrated on CT in a young woman presenting with dyspnea, with no known risk factors for embolism. Abdominal CT on further investigation showed a renal tumor invading the left renal vein and the inferior vena cava as the cause of the pulmonary embolus. In a patient presenting with pulmonary artery embolism without venous thrombosis, the differential diagnosis should include an occult tumor as the cause of the embolus. Electronic Publication  相似文献   

15.
16.
17.
18.
The overhead throwing motion generates enormous force in the elbow. Repetitive near failure loads lead to chronic adaptive changes and occasionally acute injury. The physician caring for the thrower must understand the complex anatomy and function of the elbow joint, along with the biomechanics of throwing, to accurately diagnose and treat elbow pathology. Evaluation of elbow pain in the throwing athlete must begin with a thorough and detailed throwing history including duration of symptoms, location of pain, timing during the phases of throwing motion, and associated symptoms. Physical examination should include inspection, range of motion, palpation, and specific tests to better define the pathology. A detailed history and physical examination will allow the astute clinician to obtain the proper diagnosis and start the appropriate operative or nonoperative treatment often without reliance on ancillary testing. Treatment and rehabilitation of these injuries must be tailored to the pathology present and focused towards a return to the athlete’s activity.  相似文献   

19.

Objective  

The purpose of the study was to assess the additional value of magnetic resonance (MR) elastography (MRE) to contrast-enhanced (ce) MR imaging (MRI) for breast lesion characterisation.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号