首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
AIM: To compare regional bond strength in different thirds of the root canal, among glass fiber-reinforced (FRC) endodontic posts luted with different cements, using the push-out test. MATERIAL AND METHODS: Sixty extracted human anterior teeth were endodontically treated with gutta-percha and AH Plus sealer. The crown portion was removed, and a dowel space was prepared. Prepared teeth were randomly assigned to one of six groups (n = 10) for luting glass FRC Postec posts, with one of the six cement systems (Ketac Cem Aplicap, Relyx Unicem Aplicap, Variolink II/Excite DCS, Panavia F/ED Primer, C&B cement/All-Bond 2, and Multilink/Multilink Primer A/B), using an alignment technique. Specimens were embedded in resin, and each root was sectioned into six 1-mm thick serial slices. A push-out test was performed to measure regional bond strengths and to identify the type of failure. RESULTS: The highest bond strength values were found in the cervical third and the lowest in the apical third. Highest values were obtained using Variolink II, Panavia F, and Multilink resin cements followed by C&B resin cement and Relyx Unicem ionomer resin cement; Ketac-cem ionomer cement showed the lowest value. CONCLUSION: Highest bond strength values were obtained in the cervical third and with resin cements.  相似文献   

2.
This study was designed to evaluate the micro-tensile bond strength between a carboxylic resin and dentin, when the dentin surface was modified with an experimental dentin primer. The three primers tested were ED primer II (ED), 0.3% ferric chloride aqueous solution (FE), and ED containing 0.3% ferric chloride (ED/FE). Three commercial dentin conditioners [40% phosphoric acid, 10% NaOCl, and 10% citric acid with 3% ferric chloride (10-3)] were also used. The coronal surfaces of extracted human molars were ground flat to dentin. The dentin surfaces were treated with phosphoric acid, NaOCl, or with one of the primers. The 10-3 was used without phosphoric acid or NaOCl as a control. A composite material rod was bonded to the dentin surface with 4-META/MMA-TBB resin. After 24-h immersion in 37 degrees C distilled water, 0.9 mm x 0.9 mm composite-dentin beams cut from the bonded specimens were stressed to failure in tension at 0.6 mm/min. The bond strengths were also evaluated after 5000 thermocycles. The bond strength of the group ED/FE was significantly higher than those of the 10-3, ED, and FE. After 5000 thermocycling, 10-3, ED and FE showed significant decrease in bond strength, although no significant decrease was seen for ED/FE. It was concluded that dentin surface treatment with phosphoric acid, NaOCl, and the ED/FE primer improved the bonding (p < 0.05) between 4-META/MMA-TBB resin and dentin, with or without thermocycling, while the bond strengths in the control group fell 34% following 5000 thermocycles.  相似文献   

3.
Burrow MF  Thomas D  Swain MV  Tyas MJ 《Biomaterials》2004,25(20):5031-5035
Tensile strength tests of restorative resins bonded to dentin, and the resultant strengths of interfaces between the two, exhibit wide variability. Many variables can affect test results, including specimen preparation and storage, test rig design and experimental technique. However, the more fundamental source of variability, that associated with the brittle nature of the materials, has received little attention. This paper analyzes results from micro-tensile tests on unfilled resins and adhesive bonds between restorative resin composite and dentin in terms of reliability using the Weibull probability of failure method. Results for the tensile strengths of Scotchbond Multipurpose Adhesive (3M) and Clearfil LB Bond (Kuraray) bonding resins showed Weibull moduli (m) of 6.17 (95% confidence interval, 5.25-7.19) and 5.01 (95% confidence interval, 4.23-5.8). Analysis of results for micro-tensile tests on bond strengths to dentin gave moduli between 1.81 (Clearfil Liner Bond 2V) and 4.99 (Gluma One Bond, Kulzer). Material systems with m in this range do not have a well-defined strength. The Weibull approach also enables the size dependence of the strength to be estimated. An example where the bonding area was changed from 3.1 to 1.1 mm diameter is shown. Weibull analysis provides a method for determining the reliability of strength measurements in the analysis of data from bond strength and tensile tests on dental restorative materials.  相似文献   

4.
The aim of this study was to evaluate the effects of three desensitizing agents on the shear bond strengths of four different bonding agents used to bond composite resin to dentin.A total of 160 extracted human molars were sectioned parallel to the occlusal plane under water cooling, polished and randomly divided into 4 groups of 40. Each group was treated with a different desensitizing agent (Tooth Mousse, Ultra-EZ, Cervitec Plus), except for an untreated control group. Each group was then randomly subdivided into 4 groups of 10, and a different dentin bonding agent (XP Bond, AdheSE, Adper Prompt L-pop, GBond) was applied to each group in order to bond the specimens to a resin composite (Gradia Direct) built up using a plastic apparatus. A Universal Testing Machine was used to measure the shear bond strength of each specimen. Statistical analysis was performed using one-way ANOVA and Tukey’s tests.With the exception of the Control/AdheSE and Ultra-EZ/XP Bond groups, no statistically significant differences were found in the shear bond strength values of the groups tested. These findings suggest that the use of different desensitizing agents does not affect the shear bond strength of various adhesive systems used to bond resin composite to dentin.  相似文献   

5.
背景:树脂类粘接剂粘接纤维桩的良好性能已被肯定,但不同种类树脂粘接剂的粘接性能不同。 目的:比较Bisco One-step、Clearfil DC及3M RelyX Unicem三种树脂粘接系统对纤维桩的剪切粘接强度,研究纤维桩与根管壁牙本质间的粘接性能。 方法:将15颗人离体牙在釉牙骨质界冠方1 mm处与牙体长轴方向垂直去除牙冠,磨平,常规热牙胶技术根管治疗后,随机分为3组,分别采用Bisco One-step、Clearfil DC及3M RelyX Unicem树脂粘接剂将玻璃纤维桩黏固于根管内,包埋后分别切片制备2 mm厚的样本,采用微推出法测试各组样本的粘接剪切强度;在高倍显微镜下观察所有被测样本的破坏类型。 结果与结论:Bisco One-step粘接剂组、Clearfil DC粘接剂组及3M RelyX Unicem粘接剂组的粘接强度分别为(4.69±1.85),(6.10±0.36),(7.04±0.92) MPa,Bisco One-step粘接剂组粘接强度与Clearfil DC粘接剂组、3M RelyX Unicem粘接剂组比较差异有显著性意义(P < 0.05),Clearfil DC粘接剂组粘接强度与3M RelyX Unicem粘接剂组比较差异无显著性意义。所有样本均主要为Ⅱ,Ⅳ型破坏,即脱出的桩表面完全被粘接剂覆盖或根管壁及桩表面均有部分粘接剂覆盖。表明3种粘接系统对纤维桩粘接强度差异显著,根管壁牙本质-粘接树脂界面是粘接薄弱环节。中国组织工程研究杂志出版内容重点:生物材料;骨生物材料; 口腔生物材料; 纳米材料; 缓释材料; 材料相容性;组织工程全文链接:  相似文献   

6.
Price RB  Dérand T  Andreou P  Murphy D 《Biomaterials》2003,24(6):1013-1021
Most in vitro testing of bonding systems is performed using specimens made in a mold with a low configuration (C) factor (ratio of bonded/unbonded surfaces) whereas clinically the C-factor is usually much greater. This study compared the effect of thermal cycling on the measured shear bond strength of 3M Single Bond dental adhesive bonded to dentin using molds with two different C-factors. The hypothesis was that neither C-factor nor thermal cycling would affect measured bond strengths. Resin composite was bonded to human dentin in cylindrical molds with an internal diameter of 3.2mm and either 1mm or 2.5mm deep. The 1mm deep molds had a C-factor of 2.2 and the 2.5mm deep molds had a C-factor of 4.1. Specimens were debonded either 10min after they had been bonded to dentin, or after they had been stored for 7 days in water at 37+/-1 degrees C, or after thermal cycling 5000 times for 7 days. Two-way ANOVA showed that overall both the C-factor and the storage condition had a significant effect on bond strength (p<0.001). There was a significant interaction (p<0.001) between the C-factor and how the specimens had been stored. The GLM/LSMEANS procedure with Sidak's adjustment for multiple comparisons showed that overall the specimens made in the mold with a high C-factor (4.1) had a lower bond strength than those that had been made in the mold with a lower (2.2) C-factor (p<0.001). Thermal cycling had a negative effect on the bond strength only for specimens made in molds with a C-factor of 4.1 (p<0.001).  相似文献   

7.
The adhesive performance on deproteinized dentin of different self-adhesive resin cements was evaluated through microtensile bond strength (μTBS) analysis and scanning electron microscopy (SEM). Occlusal dentin of human molars were distributed into different groups, according to the categories: adhesive cementation with two-step bonding systems-control Groups (Adper Single Bond 2 + RelyX ARC/3M ESPE; One Step Plus + Duolink/Bisco; Excite + Variolink I/Ivoclar Vivadent) and self-adhesive cementation-experimental groups (Rely X Unicem/3M ESPE; Biscem/Bisco; MultiLink Sprint/Ivoclar Vivadent). Each group was subdivided according to the dentin approach to: α, maintenance of collagen fibers and β, deproteinization. The mean values were obtained, and submitted to ANOVA and Tukey test. Statistical differences were obtained to the RelyX Unicem groups (α = 13.59 MPa; β = 30.19 MPa). All the BIS Group specimens failed before the mechanical tests. Dentinal deproteinization provided an improved bond performance for the self-adhesive cement Rely X Unicem, and had no negative effect on the other cementing systems studied.  相似文献   

8.
背景:选择适当的表面处理方法,选用适宜的黏结剂种类,可以有效地提高临床氧化锆修复体的黏结效果。 目的:研究氧化锆表面不同处理方法和黏结剂种类对Upcera氧化锆陶瓷之间剪切强度的影响。 方法:将72个试件采用600#砂纸打磨抛光分为6组,分别选择240#砂纸打磨粗化、喷砂、硅烷化3种表面处理方法,电镜观察处理前后的表面形貌。黏结剂选择Panavia F树脂水门汀和Fuji CEM树脂加强型玻璃离子水门汀,加压黏结固定24 h后,万能实验机测定剪切强度数值,进行析因方差分析。 结果与结论:喷砂组剪切强度高于240#砂纸打磨组和硅烷化组(P < 0.05)。树脂水门汀的剪切强度显著高于树脂加强型玻璃离子水门汀(P < 0.05)。喷砂后试件表面形貌最为粗糙,240#砂纸打磨和硅烷化对表面形貌的改变较小。提示喷砂是提高树脂水门汀和树脂加强型玻璃离子水门汀与氧化锆陶瓷剪切强度的有效方法,而砂纸打磨和硅烷化并不能显著提高剪切强度。对于临床黏结条件差的修复体,树脂水门汀可提供更高的黏结强度。  相似文献   

9.
背景:目前国内外对全酸蚀、自酸蚀及自黏结树脂黏结剂对纤维桩的冠向微渗漏及黏结强度影响的研究仍存在差异。 目的:评价全酸蚀、自酸蚀及自黏结3种树脂黏结剂对纤维桩黏固后冠向微渗漏及黏结强度影响。 方法:将32颗人离体上前牙随机分成5组,其中3组为实验组,2组为对照组。实验组离体牙经根管预备后,选用全酸蚀、自酸蚀及自黏结3种树脂黏结剂分别黏结直径为1.4 mm的玻璃纤维桩。体视显微镜下观察试件各剖面的微渗漏情况,再将实验组试件沿垂直牙长轴方向切成厚度为2 mm的薄片,万能材料测试机进行微推出实验,并观察试件断裂方式。阳性对照组不进行根管预备,根部涂布指甲油,冠部直接暴露于染色剂中;阴性对照组不进行根管预备,树脂覆盖根管口,将牙体整体涂布指甲油后黏蜡包埋至截面下1 mm。 结果与结论:各种树脂黏结剂均存在微渗漏现象,其中全酸蚀树脂黏结剂的微渗漏程度最轻,自酸蚀树脂黏结剂的微渗漏程度最重。3种树脂黏结剂间的微渗漏程度差异有显著性意义(P < 0.05)。黏结剂间的黏结强度由高到低分别为全酸蚀树脂黏结剂、自酸蚀树脂黏结剂、自黏结树脂黏结剂,3种黏结剂的黏结强度差异有显著性意义(P < 0.05)。试件的主要断裂方式为黏结剂/纤维桩间断裂及混合破坏。说明全酸蚀树脂黏结剂与牙本质结合紧密,与自酸蚀树脂黏结剂、自黏结树脂黏结剂比较在微渗漏程度及黏结性能方面显示出优越性。  相似文献   

10.
The purpose of this in vitro study was to compare the shear bond strengths of resin, glass-ionomer, and ceramic-based core materials to all ceramic discs. Five core materials (Core max, Sankin; Clearfil AP-X, Kuraray; Empress Cosmo, Ivoclar-Vivadent; Photocore, Kuraray; Dyract Extra, Dentsply) were prepared as discs 10 mm in diameter and 2 mm in height according to the manufacturer's instructions. Ten disc specimens per group were prepared, and dentin served as the control. All resin specimens were embedded in autopolymerizing acrylic resin, with one surface facing up. All ceramic discs (IPS Empress I, Ivoclar-Vivadent) 3 mm in diameter and 2 mm in height were prepared and bonded to core specimens with a dual-curing luting resin cement (Variolink II, Vivadent). Specimens were stored in distilled water at 37 degrees C. Shear bond strength of each sample was measured after 24 h using a universal testing machine at a crosshead speed of 0.5 mm/min. The data were analyzed with one-way analysis of variance and Tukey HSD tests (alpha = 0.05). Shear bond strength varied significantly depending on the core material used (p < 0.05). Clearfil AP-X and Photocore showed the highest shear bond strength value while Empress Cosmo provided the lowest (p < 0.05). There were no statistically significant differences among Clearfil AP-X, Photocore, and Core-Max (p > 0.05). And also there were no statistically significant differences between Dyract Extra and the control group (p > 0.05). In vitro shear bond strengths of ceramic discs bonded to resin-based core materials showed higher bond strength values than ceramic-based core material.  相似文献   

11.
This study investigated the effects of NaOCl on resin-tooth bonds to simulate the situations of long-term durability and caries invasion. Resin-tooth bonded specimens were produced with the use of two resin adhesives (Excite and One-Bond). Resin-tooth bonded beams (adhesive area; 0.9 mm2) were serially sectioned and the specimens were immersed in 10% NaOCl medium for 0 (control), 2, 4, and 6 h after being stored in water for 24 h. After immersion, microtensile bond tests were performed. SEM fractography was conducted to calculate each failure mode by image analysis. In addition, the adhesive interface was examined with the use of TEM. In the control specimens, enamel bond strengths had no difference between Excite (45.6 +/- 15.0) and One-Bond (56.9 +/- 12.9). On the other hand, dentin bond strengths had significant difference between Excite (80.6 +/- 21.2) and One-Bond (50.7 +/- 11.2). The bond strengths decreased with increased storage time for both systems with enamel and dentin bonds. The deteriorated mineralized dentin of beams resulted in bond-strength reduction for resin-enamel bonds. For dentin bonding, the adhesive interface was gradually dissolved from the outer to the center portion of the beam. The depletion of collagen fibrils within the demineralized dentin or hybrid layer deformation was found under SEM and TEM examinations. These morphological changes are responsible for bond strength reduction of resin-dentin bonds.  相似文献   

12.
The study evaluated the in vitro influence of pulse-repetition rate of Er:YAG laser and dentin depth on tensile bond strength of dentin-resin interface. Dentin surfaces of buccal or lingual surfaces from human third molars were submitted to tensile test in different depths (superficial, 1.0 and 1.5 mm) of the same dental area, using the same sample. Surface treatments were acid conditioning solely (control) and Er:YAG laser irradiation (80 mJ) followed by acid conditioning, with different pulse-repetition rates (1, 2, 3, or 4 Hz). Single bond/Z-250 system was used. The samples were stored in distilled water at 37 degrees C for 24 h, and then the first test (superficial dentine) was performed. The bond failures were analyzed. Following, the specimens were identified, grounded until 1.0- and 1.5-mm depths, submitted again to the treatments and to the second and, after that, to third-bond tests on a similar procedure and failure analysis. ANOVA and Tukey test demonstrated a significant difference (p < 0.001) for treatment and treatment x depth interaction (p < 0.05). The tested depths did not show influence (p > 0.05) on the bond strength of dentin-resin interface. It may be concluded that Er:YAG laser with 1, 2, 3, or 4 Hz combined with acid conditioning did not increase the resin tensile bond strength to dentin, regardless of dentin depth.  相似文献   

13.
The study evaluated the influence of different luting materials on the microtensile bond strength of glass fiber posts to root canal dentin. Thirty extracted maxillary premolars were endodontically treated, and the roots were prepared for post cementation using the FRC Postec system (Vivadent). Two luting materials (Multilink, Vivadent and Clearfil Photo Core, Kuraray) were used in combination with three adhesive: Multilink Primer (Vivadent), Clearfil Photo Bond, and Clearfil New Bond (Kuraray). A composite build-up was performed around the root to provide adequate gripping during testing. Specimens were cut to obtain beams with the post in the center and with the radicular dentin overlaid by the composite build-up on each side. Microtensile testing was performed with a universal testing machine at a cross-head speed of 0.5 mm/min. The failure mode was classified under a stereomicroscope and four representative beams of each group were selected for SEM analysis. Bond strength data that were analyzed with two-way ANOVA and Student-Newman-Keuls multiple comparisons tests revealed that adhesive systems, luting materials, and the interaction between these two factors significantly influenced the bond strength results (p < 0.01). Multilink applied with its own adhesive system obtained the best results, while the lowest bond strength was achieved with clearfil photo core in combination with multilink primer.  相似文献   

14.
This study investigates the effect of structural changes of collagen fibrils on the bonding durability of a total etch luting resin (Super-Bond C&B) and a self-etching luting resin (Panavia F 2.0) to dentin. An atomic force microscope (AFM) was used to observe structural changes of intact dentin collagen fibrils after acidic conditionings of two bonding systems. After 90 d water storage and 15,000 thermal cycles (TC) as artificial aging, micro-tensile bond strength (microTBS) was utilized to evaluate the bonding durability of the two bonding systems to dentin. microTBS after 1 d or 90 d water storage without TC were separately measured in control groups. A cross-banding periodicity of about 67 nm along collagen fibrils was seen on demineralized intertubular dentin surfaces in AFM images. For both luting resins, thermal cycling decreased (p < 0.05) microTBS of 1 d and 90 d, compared to controls. Scanning electron microscope and transmission electron microscopic examinations revealed that the top and bottom of hybrid layer (HL) were weak links in the bonding interface over time. The results suggest that the top of HL contains disorganized collagen fibrils from the smear layer which degrade over time. AFM results indicate that the demineralized intact collagen fibrils beneath the smear layer were not denatured during acidic conditioning. However, these collagen fibrils may be structurally unstable due to poor infiltration by resin or loss of resin protection within the HL over time, reducing the long-term microTBS. This process was accelerated by thermal fatigue cycling.  相似文献   

15.
The clinical performance of directly bonded resin composites is fundamentally dependent on durable adhesion to prevent gap formation over time. The goal of this investigation was to evaluate the effectiveness of various dentin adhesives by means of quasistatic and dynamic dentin bond strengths, and also to determine marginal and internal gap formation after loading in an artificial oral environment. Three hundred thirty human third molars were used within four weeks of extraction. Adhesives used were A.R.T. Bond, OptiBond FL, Scotchbond Multi-Purpose Plus, Single Bond, Prime & Bond NT, and One Up Bond F for bonding of one resin composite (Z 250). Buccal and lingual aspects of 90 teeth were ground flat to expose dentin, then resin composite cylinders were bonded. Initial bond strengths (n = 10) and adhesive fatigue limits (n = 20) were determined with the use of a shear test apparatus. One hundred eighty conical cavities were prepared into dentin discs and filled with the same materials. After 21 days of storage, initial push-out bond strengths (n = 10) and adhesive fatigue limits (n = 20) were measured. Sixty molars with MO cavities (n = 10) with margins below the cement-enamel junction were filled. Before and after thermomechanical loading (100000 x 50 N and 2500 x thermocycling between + 5 and + 55 degrees C), marginal gap formation and internal adaptation (only after loading) were analyzed under a SEM (x 200). The one-bottle systems showed higher shear bond strengths when evaluated statically and dynamically. However, cyclic fatigue push-out bond strengths resulted in higher values for older multistep systems. Marginal and internal gap analysis confirmed the results, in favor of older adhesive systems (p <.05; Mann-Whitney U test).  相似文献   

16.
It was recently reported that removal of the collagen network from etched dentin does not affect dentin bond strengths. The aim of this study was to determine if the removal of the collagen fibers results in changes in dentin roughness and wettability. Twenty cary-free extracted human third molars were sectioned parallel to the occlusal surface to expose either superficial or deep dentin. Dentin was ground flat through 600-grit SiC abrasive paper under water to provide uniform surfaces. Observed contact angle measurements were performed to assess wettability by using the axisymmetric drop shape analysis technique using water and a water-based primer. Average roughness was determined with a profilometer. The specimens were analyzed just after being ground, after etching with 35% H(3)PO(4) gel for 15 s, and after etching and deproteinization with 5% NaOCl for 2 min. Data were analyzed with two-way ANOVA and Newman-Keuls multiple comparison t test procedure. Etching resulted in an increase in surface roughness and dentin wettability. For deep dentin, collagen removal did not influence the average roughness, but it resulted in a significantly greater degree of wettability. The degree of wettability for deep dentin was greater than for superficial dentin.  相似文献   

17.
Endodontic access cavities sometimes can be prepared through a permanent composite restoration. Between the appointments, temporary cements are used to seal access cavities and may have negative effect on bonding of further composite restoration. The purpose of this study was to compare shear bond strength of composite to composite which had been in contact with various temporary filling materials. Standard cavities were prepared on 160 acrylic resin blocks, obturated with composite resin (Clearfil AP-X, Kuraray, Japan) and randomly divided into eight groups (n = 20). Group 1 received no treatment. From group 2-8, composite surfaces were covered with the following cements temporarily: Zinc-oxide/calcium-sulphate (Cavit-G, ESPE, Germany), two different Zinc-Oxide-Eugenol materials (ZnOE, Cavex, Holland and IRM, Dentsply, USA), Zinc-phosphate cement (Adhesor, Spofa-Dental, Germany), Zinc-polycarboxylate cement (Adhesor-Carbofine, Spofa-Dental, Germany), Glass-Ionomer-Cement (Argion-Molar, Voco, Germany), or light curing temporary material (Clip, Voco, Germany). The cements were removed mechanically after 1 week storage in distilled water at 37 degrees C and composite surfaces were treated with a self-etch adhesive system (SE-Bond, Kuraray, Japan). Composite resin build-ups were created on composite surfaces. Shear bond strength values were measured using universal testing machine at crosshead speed of 1 mm/min. The data was calculated in MPa and statistically analyzed using one-way ANOVA and Tukey tests. Eugenol-containing cements significantly reduced shear bond strengths of composite to composite (p < 0.05), while the other temporary materials had no adverse effect on shear bond strength (p > 0.05). These findings suggested that temporary filling materials except eugenol-containing materials have no negative effect on composite repair bond strengths.  相似文献   

18.
The purpose of this study was to evaluate the influence of intrapulpal pressure and dentin depth on bond strengths of an etch-and-rinse and a self-etching bonding agent to dentin in vitro and in vivo. Twenty-four pairs of premolars were randomly divided into four groups (n = 6) according to the dentin bonding agent, Single Bond and Clearfil SE Bond, and intrapulpal pressure, null or positive. Each tooth of the pair was further designated to be treated in vivo or in vitro. The intrapulpal pressure was controlled in vivo by the delivery of local anesthetics containing or not a vasoconstrictor, while in vitro, it was achieved by keeping the teeth under hydrostatic pressure. Class I cavities were prepared and the dentin bonding agents were applied followed by incremental resin restoration. For the teeth treated in vitro, the same restorative procedures were performed after a 6 month-storage period. Beams with 1 mm(2) cross-sectional area were prepared and microtensile tested. Clearfil SE Bond was not influenced by any of the variables of the study, while bond strengths produced in vitro were significantly higher for Single Bond. Overall, lower bond strengths were produced in deep dentin, which reached statistical significance when Single Bond was applied under physiological or simulated intrapulpal pressure. In conclusion, in vitro bonding may overestimate the immediate adhesive performance of more technique-sensitive dentin bonding systems. The impact of intrapulpal pressure on bond strength seems to be more adhesive dependent than dentin morphological characteristics related to depth.  相似文献   

19.
The success of the oral rehabilitation of implant patients depends not only on the osseointegration of implant fixtures but also on maintaining the integrity of the connection of prosthetic superstructures to these fixtures. It was an objective of the present study to evaluate and compare cement bond strengths among rolled (R), cast (C) and metal-injection-molded (M) commercially pure titanium plates which were bonded with Panavia 21 (Kuraray) and Imperva (Shofu) cements. Two plates (15x5x1 mm) of each R, C, and M were lap-jointed (lap length: 5 mm). The joints were stored in 37 degrees C distilled water for 24 h, followed by tensile tests with an INSTRON system under 1 mm/min crosshead speed. It was found that the bond strength of R with Panavia 21 (PAN) was 5.31 (SD:1.5) MPa and 2.30 (0.83) MPa with Imperva (IMP) cement. These were improved by applying an alloy primer to 7.08 (1.31) MPa and 6.72 (1.63) MPa, respectively. Using PAN with primer application, C and M samples showed bond strengths of 7.99 (1.31) and 7.20 (2.50) MPa, while they were 5.83 (2.15) and 6.79 (2.09) MPa using IMP with primer. There was a significant difference (p<0.01) between PAN and IMP cements for C samples. Additionally, samples were pre-oxidized at 100 degrees C in air for 10 min. Bond strengths of PAN with the primer were 5.69 (2.25), 9.14 (1.28), and 5.60 (3.13) MPa for R, C, and M sample groups. If the cement with the primer was applied immediately after the polishing (instead of pre-oxidized surfaces), bond strengths were improved to 9.14 (1.78) for R, 9.29 (1.85) for C, and 9.36 (1.81) MPa for M sample group. At p<0.05 level, there was a significant difference between surface pre-condition of R and M, but no significance with C.  相似文献   

20.
The aim of this study was to compare the microtensile bond strength of the etch and rinse adhesive versus one-component or two-component self-etch adhesives. Twelve intact human molar teeth were cleaned and the occlusal enamel of the teeth was removed. The exposed dentin surfaces were polished and rinsed, and the adhesives were applied. A microhybride composite resin was applied to form specimens of 4?mm height and 6?mm diameter. The specimens were sectioned perpendicular to the adhesive interface to produce dentin-resin composite sticks, with an adhesive area of approximately 1.4?mm(2). The sticks were subjected to tensile loading until failure occurred. The debonded areas were examined with a scanning electron microscope to determine the site of failure. The results showed that the microtensile bond strength of the etch and rinse adhesive was higher than that of one-component or two-component self-etch adhesives. The scanning electron microscope examination of the dentin surfaces revealed adhesive and mixed modes of failure. The adhesive mode of failure occurred at the adhesive/dentin interface, while the mixed mode of failure occurred partially in the composite and partially at the adhesive/dentin interface. It was concluded that the etch and rinse adhesive had higher microtensile bond strength when compared to that of the self-etch adhesives.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号