首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The goal of the present work was to establish the relative influence of one exogenous variable versus one endogenous variable on the fully-reversed tension-compression fatigue performance of bone cement. The method used to mix the cement constituents was the exogenous variable, while the viscosity of the mixed cement dough was the endogenous variable. Two commercial cement formulations (Palacos R and Osteopal) and two cement mixing methods (hand mixing and vacuum mixing) were used. It was found that for a given mixing method, cement viscosity exerts a marginal influence on fatigue performance. On the other hand, for a given cement formulation, vacuum mixing led to a statistically significant improvement in fatigue performance. The present results demonstrate the superior influence of mixing method over cement viscosity.  相似文献   

2.
The fatigue properties of Simplex P and Palacos R bone cements were compared to their antibiotic impregnated counterparts AKZ* and Palacos R with gentamycin. The effect of porosity reduction by centrifugation of all four cement types was also assessed. Fifteen specimens of each cement type were prepared according to manufacturer's instructions and 15 additional specimens of each cement type were prepared by mixing the powder with chilled monomer (0 degrees C) and then centrifuging the cement immediately after mixing. Fifteen fully reversed tension-compression fatigue tests were performed at 15 MPa in stress control for each cement preparation in vitro while simulating the in vivo state (37 degrees C and 100% humidity). The number of cycles to failure were recorded. There was no significant difference in the fatigue life of Palacos R and Simplex P when both cements were prepared in the standard fashion. The addition of 1/2 g of gentamycin to Palacos R did not significantly alter its fatigue properties. The addition of 0.5 g of erythromycin and 0.24 g of colistin did not decrease the fatigue life of Simplex P. Centrifugation significantly improved the fatigue properties of Simplex P and AKZ. The fatigue lives of Palacos R and Palacos R with gentamycin were not improved by centrifugation. The fatigue life of centrifuged Simplex P was significantly greater than the fatigue life of Palacos R and of Palacos R with gentamycin, whether the Palacos R based cements were centrifuged or not.  相似文献   

3.
This paper reports on the damaging effects of different percentage porosities on the fatigue life of acrylic bone cement as used in the fixation of orthopaedic implants. Both hand-mixed (HM) and vacuum-mixed (VM) specimens containing different levels of porosity were fatigue tested to failure. A negative correlation between porosity level and fatigue life was demonstrated for both techniques. Considerable scatter was present in the data. Using the pore size distributions for HM and VM cement virtual HM and VM specimens were created containing various levels of porosity. Incorporating the effect of pore size and pore clustering quantified previously using the theory of critical distances a fatigue life prediction could be obtained for the virtual specimens. The virtual data agreed strongly with the experimental findings, predicting the correlation and more significantly the scatter in the experimental results. Using the virtual porosity failure model, it was demonstrated that given a constant porosity the fatigue life can vary by over an order of magnitude in both HM and VM cement. This suggests that not only porosity level but pore size distribution is extremely important in controlling the fatigue life of bone cement. It was verified that pore clustering and pore size are the major contributors to failure in HM and VM cement respectively. Furthermore, given the beneficial effects of porosity it has been proposed that an even distribution of small pores would provide an optimal bone cement mantle. Using the virtual model, it was determined that neither technique was capable of achieving such a distribution indicating a need for a new more reliable technique. The TCD based virtual porosity failure model should prove to be a powerful tool in the design of such a technique.  相似文献   

4.
Lewis G  Janna S 《Biomaterials》2003,24(23):4315-4321
Constant-amplitude uniaxial tension-compression fatigue tests were conducted on specimens fabricated from 12 sets of acrylic bone cements, covering cement formulations with three different viscosities (so-called "high-", "medium-" and "low-viscosity" varieties), two different methods of mixing the cement constituents (so-called "hand-" and "vacuum-mixed" methods) and two test specimen shapes (rectangular-cross-sectioned or "flat" and circular-cross-sectioned or "round"). The test results-namely, the number of fatigue stress cycles, N(f)-were analyzed using the linearized transformation of the three-parameter Weibull relationship, allowing the values of the Weibull mean, N(WM), to be determined for each set. Values ranged from 14,300 to 1,284,331 for the round specimen sets and from 2898 to 72,960 for the flat specimen sets. Statistical analysis of the ln N(f) data, together with an examination of the N(WM) values, showed that, for any combination of cement formulation and mixing method, round specimens had significantly longer fatigue lives compared to flat ones. These results are explained in terms of two factors. The first is the smaller surface area of the waisted zone in the round specimens compared to that in the flat specimens (nominal value of 157mm(2) versus nominal value of 185mm(2)), leading to the possibility of fewer crack initiation sites on the round specimens compared to the flat ones. Secondly, it is postulated that the crystallinity of the round specimens was higher than that of the flat ones, a consequence of the significantly lower measured residual liquid monomer contents of the former compared to the latter (3.40+/-1.28wt%/wt compared to 3.81+/-1.48wt%/wt). The significance of the present finding is that it indicates that, for a set of bone cement formulation and experimental conditions, discriminating fatigue test results are more likely to be obtained if flat, rather than round, test specimens are used.  相似文献   

5.
The goal of the present work was to investigate the influence of the viscosity classification of an acrylic bone cement on its in vitro fatigue performance, as determined in fully-reversed tension-compression (+/-15 MPa) fatigue tests. The test matrix comprised six commercially available bone cements [Orthoset1, (OS1), Orthoset(R)3 (OS3), CemexRX (CRX), Cemex XL (CXL), Palacos R (PR) and Osteopal (OP)], two methods of mixing the cement constituents (hand-mixing and vacuum-mixing), two methods of fabricating the test specimens (direct molding and molding followed by machining), two specimen cross-sectional shapes (rectangular or "flat" and circular or "round"), and four test frequencies (1, 2, 5, and 10 Hz). In total, 185 specimens, distributed among 20 sets, were tested. The test results (number of fatigue stress cycles, N_f) were processed using the linearized transformation of the three-parameter Weibull distribution, whence estimates of the Weibull mean, N_[WM], were obtained. Statistical analysis of the ln N_f results (Mann-Whitney test; alpha<0.05) and a comparison of the N_[WM] estimates for specimen sets in which the formulations have essentially the same composition but different viscosity classification (namely, OS1 versus OS3, CRX versus CXL, and PR versus OP) showed that, in the majority of the comparisons carried out, the viscosity classification of a bone cement does not exert a significant influence on its in vitro fatigue performance.  相似文献   

6.
The mechanical properties of the three cement preparations most widely used in the United States were compared by conducting tensile and fatigue tests on Simplex P, LVC, and Zimmer Regular bone cements. Specimens of all three cement preparations were prepared for mechanical testing with and without centrifugation of the cement immediately after mixing. Although the results of the tensile testing revealed a few specific instances of significant differences in the tensile properties of the three cement preparations, there was no consistent evidence that one cement was superior in tension to the others. However, the fatigue properties of Simplex P were consistently and significantly superior to the fatigue properties of both LVC and Zimmer Regular bone cements. Centrifugation of the cement immediately after mixing significantly improved both the tensile and fatigue properties of all three bone cements. However, the fatigue strength of centrifuged Simplex P was substantially and significantly superior to the fatigue strength of the centrifuged LVC and Zimmer Regular bone cements. Since in total joint replacements bone cement is subjected to cyclic loading, these data suggest that centrifuged Simplex P is a preferable bone cement to LVC and to Zimmer Regular cement with or without centrifugation.  相似文献   

7.
Zinc phosphate cements are commonly supplied as two components, powder and liquid, and the proportions of the constituents are determined by operator experience. A capsulated system which is mechanically mixed has been marketed and this study investigated the performance of the encapsulated cement system. The mean fracture strength, standard deviation and associated Weibull Moduli (m) of encapsulated cements were determined by compressive fracturing 20 cement specimens filled directly from the mixing syringe or from narrower cement tubes. Pore distribution within the cylindrical specimens was determined using image analysis to assess the influence of the method of mould filling with the cement. The strength data showed variation in magnitude and consistency ranging from 44.6+/-13.7 MPa (m = 3.18+/-0.71) for cements filled directly from the syringe to 61.0+/-7.8 MPa (m = 8.35+/-1.87) for cements filled from cement tubes. Larger pores were found in specimens consolidated directly from the cement syringe. Mechanical mixing of the encapsulated cement resulted in air entrapment in the cement mix which manifested itself as large pores (over 200 microm diameter) within the cylindrical specimens. The smaller orifice of the cement tube compared with the syringe was considered to be responsible for eliminating the majority of the air entrapped in the cement mass during mixing. Whilst mechanical mixing of encapsulated cements is quicker and more convenient, the encapsulated specimens consolidated according to the manufacturers instructions from the syringe offered no significant advantage in terms of reliability or strength over hand-mixed cements in this investigation.  相似文献   

8.
Polymethylmethacrylate bone cement, containing either no added antibiotic, 0.5 g of Vancomycin, 1.0 g of Vancomycin, or 1.0 g of Tobramycin, was mixed either in air or a vacuum chamber. Following storage in a water bath at 37 degrees C for 48 h, the specimens were tested in four-point bending. The porosity of the specimens was assessed radiographically, and their antibacterial activity was monitored for 21 days. The bending strength of the vacuum mixed specimens containing no antibiotic was 40% greater than that of similar air-mixed specimens. However, there were no significant differences in the bending strength of either the air- or vacuum-mixed specimens when any of the antibiotic dosages were added. The bending modulus of the vacuum-mixed specimens, containing no antibiotic, was significantly greater than the moduli of all the other specimen groups which did not differ from each other. Vacuum mixing reduced the apparent porosity of the specimens fivefold, and while the addition of antibiotic did not effect porosity of the air-mixed specimens, that of the vacuum-mixed specimens was doubled. Although initial rapid decreases were seen, leaching of antibiotic from the cement and antibacterial activity continued through the 21-day monitoring period.  相似文献   

9.
The influence of the storage temperature of the cement constituents prior to mixing (21 vs. 4 degrees C) and the mixing method (hand mixing vs. vacuum mixing) on the uniaxial tension-compression fatigue performance and porosity of Palacos R acrylic bone cement was studied. The fatigue results were analyzed using the three-parameter Weibull equation. The fatigue performance was expressed as an index I, which was defined as the product of the Weibull characteristic fatigue life and the square root of the Weibull slope. Statistical analyses of these results show that although the mixing method (for a given storage temperature) exerts a significant influence on the fatigue performance and areal porosity, the effect of storage temperature (for a given mixing method) on either of these parameters is not significant.  相似文献   

10.
Over the past three decades or so, a very large volume of literature has been generated on the impact of an assortment of variables on the fatigue lifetimes of a large number of acrylic bone-cement formulations. In the present article, this literature is examined critically to reveal areas of agreement, areas of disagreement, as well as a welter of underexplored and unexplored topics. For example, there is unanimity of support for the notion that an increase in the molecular weight of the powder constituents or the fully cured cement leads to an increase in the cement's fatigue life, whereas there is disagreement as to whether vacuum mixing the cement constituents leads to an increase in the fatigue life of the fully cured cement (relative to the hand-mixed counterpart). Among the underexplored topics is systematic study of the effect of test frequency on the fatigue results, whereas determination of the optimal concentration of the antibiotic in an antibiotic-loaded cement is an example of the unexplored topics. It is pointed out that resolving the controversies, addressing the underexplored topics, and filling the lacunae will allow comprehensive evaluations of acrylic bone-cement materials to be made. This enhanced body of knowledge will prove invaluable in the continued use of acrylic bone cement as the anchoring agent in cemented arthroplasties.  相似文献   

11.
Porous-free, two-solution bone cements have been developed in our laboratory as an alternative to commercial powder/liquid formulations. Each pair of solutions consist of poly(methyl methacrylate) (PMMA) powder dissolved in methyl methacrylate (MMA) monomer, with benzoyl peroxide (BPO) added to one solution as the initiator and N,N-dimethyl-p-toluidine (DMPT) added to the other as the activator. When mixed, the solutions polymerize via a free radical reaction, which is governed by the concentrations of initiator and activator and their molar stoichiometry. Previous work by the authors has demonstrated that these two-solution cement compositions are comparable to Simplex P bone cement in polymerization exotherm, setting time, and flexural mechanical properties. This study was designed to evaluate the effect of BPO and DMPT concentrations, along with their molar ratio, on the fracture toughness, fatigue strength, and residual monomer content of the experimental compositions. The results showed that fracture toughness and fatigue strength for the solution cements were comparable to Simplex P and were not significantly affected by the BPO concentration or the BPO:DMPT molar ratio; however, the highest DMPT concentration yielded significantly lower values for both variables. Residual monomer content was significantly affected by both the individual concentrations of BPO and DMPT and their molar ratios. The two-solution cements had significantly higher residual monomer contents versus Simplex P; however, this can be attributed to their higher initial monomer concentration rather than a lower degree of conversion.  相似文献   

12.
The objective of this study was to investigate the release mechanism and kinetics of the antimicrobial peptide, Dhvar-5, both alone and in combination with gentamicin, from a standard commercial polymethyl methacrylate (PMMA) bone cement. Different amounts of Dhvar-5 were mixed with the bone cement powders of Osteopal and the gentamicin-containing Osteopal G bone cement and their release kinetics from the polymerized cement were investigated. Additionally, the internal structure of the bone cements were analysed by scanning electron microscopy (SEM) of the fracture surfaces. Secondly, porosity was investigated with the mercury intrusion method and related to the observed release profiles. In order to obtain an insight into the mechanical characteristics of the bone cement mixtures, the compressive strength of Osteopal and Osteopal G with Dhvar-5 was also investigated. The total Dhvar-5 release reached 96% in the 100 mg Dhvar-5/g Osteopal cement, whereas total gentamicin release from Osteopal G reached only 18%. Total gentamicin release increased significantly to 67% with the addition of 50mg Dhvar-5/g, but the Dhvar-5 release was not influenced. SEM showed an increase of dissolved gentamicin crystals with the addition of Dhvar-5. The mercury intrusion results suggested an increase of small pores (< 0.1 microm) with the addition of Dhvar-5. Compressive strength of Osteopal was reduced by the addition of Dhvar-5 and gentamicin, but still remained above the limit prescribed by the ISO standard for clinical bone cements. We therefore conclude that the antimicrobial peptide, Dhvar-5, was released in high amounts from PMMA bone cement. When used together with gentamicin sulphate, Dhvar-5 made the gentamicin crystals accessible for the release medium presumably through increased micro-porosity (< 0.1 microm) resulting in a fourfold increase of gentamicin release.  相似文献   

13.
A theoretical basis for understanding polymerization shrinkage of bone cement is presented based on density changes in converting monomer to polymer. Also, an experimental method, based on dilatometry and the Archimedes' principle is presented for highly precise and accurate measurement of unconstrained volumetric shrinkage of bone cement. Furthermore, a theoretical and experimental analysis of polymerization shrinkage in a constrained deformational state is presented to demonstrate that porosity can develop due to shrinkage. Six bone-cement conditions (Simplex-Ptrade mark vacuum and hand mixed, Endurancetrade mark vacuum mixed, and three two-solution experimental bone cements with higher initial monomer levels) were tested for volumetric shrinkage. It was found that shrinkage varied statistically (p< or = 0.05) from 5.1% (hand-mixed Simplex-Ptrade mark) to 6.7% (vacuum-mixed Simplex-Ptrade mark) to 10.5% for a 0.6:1 (polymer g/monomer mL) two-solution bone cement. Shrinkage was highly correlated with initial monomer content (R(2) = 0.912) but with a lower than theoretically expected rate. This discrepancy was due to the presence of residual monomer after polymerization. Using previously determined residual monomer levels, the theoretic shrinkage analysis was shown to be predictive of the shrinkage results with some residual monomer left after polymerization. Polymerization of a two-solution bone cement in a constrained state resulted in pores developing with volumes predicted by the theory that they are the result of shrinkage. The results of this study show that shrinkage of bone cement under certain constrained conditions may result in the development of porosity at the implant-bone cement interface and elsewhere in the polymerizing cement mantle.  相似文献   

14.
In total hip replacement, fixation of a prosthesis is in most cases obtained by the application of methacrylic bone cements. Most of the commercially available bone cements contain barium sulphate or zirconium dioxide as radiopacifier. As is shown in the literature, the presence of these inorganic particles can be unfavourable in terms of mechanical and biological properties. Here, we describe a new type of bone cement, where X-ray contrast is obtained via the introduction of an iodine-containing methacrylate copolymer; a copolymer of methylmethacrylate and 2-[4-iodobenzoyl]-oxo-ethylmethacrylate (4-IEMA) is added to the powder component of the cement. The properties of the new I-containing bone cement (I-cement) are compared to those of a commercially available bone cement, with barium sulphate as radiopacifier (B-cement). The composition of the I-cement is adjusted such that similar handling properties and radiopacity as for the commercial cement are obtained. In view of the mechanical properties, it can be stated that the intrinsic mechanical behaviour of the I-cement, as revealed from compression tests, is superior to that of B-cement. Concerning the fatigue behaviour it can be concluded that, though B-cement has a slightly higher fatigue crack propagation resistance than I-cement, the fatigue life of vacuum-mixed I-cement is significantly better than that of B-cement. This is explained by the presence of BaSO4 clumps in the commercial cement; these act as crack initiation sites. The mechanical properties (especially fatigue resistance) of the new I-cement warrant its further development toward clinical application.  相似文献   

15.
Fleming GJ  Farooq AA  Barralet JE 《Biomaterials》2003,24(23):4173-4179
The influence of powder/liquid mixing regime on the performance of a hand-mixed restorative glass-ionomer cement (GIC) was evaluated in terms of compressive strength, working characteristics and the porosity distribution.Mean compressive fracture strengths, standard deviations and associated Weibull moduli (m) were determined from series of 20 cylindrical specimens (6mm height, 4mm diameter) prepared by hand-mixing the relative proportions of the powder and liquid constituents. Working characteristics were assessed using an oscillating rheometer whilst scanning electron microscopy and image analysis were used to investigate the influence of the mixing regime on pore distribution.For a constant volume of liquid (1ml) the mean compressive strength decreased from 102.1+/-23.1MPa for 7.4g of powder, to 93.8+/-22.9, 82.6+/-18.5 and 55.7+/-17.2MPa for 6.66, 5.94 and 3.7g of powder, respectively. A concomitant increase in both the working and setting times was also observed.GICs manipulated to a powder/liquid mixing consistency below the manufacturers' recommend ratio, for a constant volume of liquid, resulted in reduced porosity levels in the cement mass and extended working and setting times. Unfortunately, a reduction in the concentration of reinforcing glass particles in the set material below that specified by the manufacturers decreases the cements' load bearing capacity so that they fail at lower compressive stress levels in the posterior region of the mouth.  相似文献   

16.
In this study, a determination is made of the effect of loading rate, v (0.1 mm min(-1) versus 1.0 mm min(-1) versus 10 mm min(-1)) on the value of the plane strain fracture toughness, K(Ic), of three commercial formulations of acrylic bone cement (Osteopal), CMW3, and Copal), that are characterized as "low-", "medium-", and "high-" viscosity brands, respectively). For all formulations, K(Ic) increases with increase in v. However, while this trend is statistically significant for CMW3 and Copal, this is not so for Osteopal. The CMW3 and Copal results are explained in terms of changes of the molecular relaxation transitions in the cement and the thermal state at the crack tip of the test specimen. Two implications of the findings are discussed. In the case of Osteopal, a recommendation for further study is made.  相似文献   

17.
Two different methods have been used to fatigue test four bone cements. Each method has been used previously, but the results have not been compared. The ISO 527-based method tests a minimum of 10 samples over a single stress range in tension only and uses Weibull analysis to calculate the median number of cycles to failure and the Weibull modulus. The ASTM F2118 test regime uses fewer specimens at various stress levels tested in fully reversed tension–compression, and generates a stress vs. number of cycles to failure (S–N) or Wöhler curve. Data from specimens with pores greater than 1 mm across is rejected. The ISO 527-based test while quicker to perform, provides only tensile fatigue data, but the material tested includes pores, thus the cement is closer to cement in clinical application. The ASTM regime uses tension and compression loading and multiple stress levels, thus is closer to physiological loading, but excludes specimens with defects obviously greater than 1 mm, so is less representative of cement in vivo. The fatigue lives between the cements were up to a factor 15 different for the single stress level tension only tests, while they were only a factor of 2 different in the fully reversed tension–compression testing. The ISO 527-based results are more sensitive to surface flaws, thus the differences found using ASTM F2118 are more indicative of differences in the fatigue lives. However, ISO 527-based tests are quicker, so are useful for initial screening.  相似文献   

18.
An organic-inorganic hybrid material, epoxy-SiO(2), was prepared by incorporating epoxy structure units covalently into a SiO(2) glass network via the sol-gel approach. The precursor was obtained by the reaction of diglycidyl ether of bisphenol A (DGEBA) with 3-aminopropyl trimethoxysilane (APTS). The precursor was then hydrolyzed and co-condensated with tetraethyl orthosilicate (TEOS) in tetrahydrofuran (THF) at room temperature to yield epoxy-SiO(2) hybrid sol-gel material having a 50 wt % SiO(2) content. Thermal properties of the hybrid material were characterized by differential scanning calorimetry (DSC) and thermogravimetric analysis (TGA). The hybrid sol-gel material epoxy-SiO(2) was the solid, powder component of bone cement. The liquid component contains bis-phenol-A glycidyl methacrylate (Bis-GMA), triethyleneglycol dimethacrylate (TEGDMA), and methyl methacrylate (MMA) with 25, 55, and 20 vol %, respectively. We discuss the comparison between the new epoxy-SiO(2) bone cement and the commercial Simplex P bone cement. Mechanical properties such as Young's modulus, compressive strength, hardness, and impact strength of the new epoxy-SiO(2) bone cement exceeded those of Simplex P bone cement. The tensile and bending strengths of the new epoxy-SiO(2) bone cement were approximately the same as those of Simplex P bone cement. In order to evaluate the biocompatibility of the new bone cement, an MTT test and optical microscopy were conducted in cell culture. Results indicated that the new epoxy-SiO(2) bone cement exhibits very low cytotoxicity compared with Simplex P bone cement.  相似文献   

19.
This paper reports on the effects of porosity and its distribution on the fatigue strength of bone cement. Hand-mixed (HM) and vacuum-mixed (VM) bone cement samples were fatigue tested to failure. The point of failure commonly coincided with large single pores (in the VM materials) and multiple pores in clusters (in the HM material). The effect of pores was analysed using the Theory of Critical Distances (TCD), a theory previously developed to explain the effect of notches and other stress concentrations on fatigue and fracture. Clusters of pores were analysed by developing a criterion to decide whether local cracking would act to link pores together, forming a single stress concentration of more complex shape. This approach enabled us to predict the high-cycle fatigue strength of samples containing clusters of pores, with good accuracy (errors less than 13%). We then used the analysis to develop general rules for the effect of pore size and proximity on fatigue strength. For example, we showed that a single pore of 2mm diameter or more would cause a significant decrease in the fatigue strength (compared to that of pore-free material); however, two pores of only 1mm diameter in close proximity would be equally damaging. This demonstrates the importance not only of pore size but also of pore density and distribution. However, pores do have beneficial effects such as improved drug dispersion, bone ingrowth and crack tip blunting. Therefore, given the findings from this study, a possible step forward in the development of surgical bone cements may involve a compromise in which relatively small pores are evenly distributed throughout the material.  相似文献   

20.
Augmentation of acrylic bone cement with multiwall carbon nanotubes   总被引:1,自引:0,他引:1  
Acrylic bone cement, based on polymethylmethacrylate (PMMA), is a proven polymer having important applications in medicine and dentistry, but this polymer continues to have less than ideal resistance to mechanical fatigue and impact. A variety of materials have been added to bone cement to augment its mechanical strength, but none of these augmentative materials has proven successful. Carbon nanotubes, a new hollow multiwalled tubular material 10-40 nm in diameter, 10-100 microm long, and 50-100 times the strength of steel at 1/6 the weight, have emerged as a viable augmentation candidate because of their large surface area to volume ratio. The objective of this study was to determine if the addition of multiwall carbon nanotubes to bone cement can alter its static or dynamic mechanical properties. Bar-shaped specimens made from six different (0-10% by weight) concentrations of multiwall carbon nanotubes were tested to failure in quasi-static 3-point bending and in 4-point bending fatigue (5 Hz). Analyses of variance and the 3-Parameter Weibull model were used to analyze the material performance data. The 2 wt % MWNT concentration enhanced flexural strength by 12.8% (p=0.003) and produced a 13.1% enhancement in yield stress (p=0.002). Bending modulus increased slightly with the smaller (<5 wt % MWNT) concentrations, but increased 24.1% (p<0.001) in response to the 10 wt % loading. While the 2 wt % loading produced slightly improved quasi-static test results, it was associated with clearly superior fatigue performance (3.3x increase in the Weibull mean fatigue life). Weibull minimum fatigue life (No), Weibull modulus (alpha), and characteristic fatigue life (beta) for bone cement augmented with carbon nanotubes were enhanced versus that observed in the control group. These data unambiguously showed that the bone cement-MWNT polymer system has an enhanced fatigue life compared to "control" bone cement (no added nanotubes). It is concluded that specific multiwall carbon nanotube loadings can favorably improve the mechanical performance of bone cement.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏