目的:探讨白内障超声乳化联合人工晶状体(IOL)囊袋内悬吊固定治疗晶状体半脱位(SL)的疗效。

方法:回顾性分析2014-06/2017-12于我院就诊的SL(悬韧带断离范围≤270°)患者18例18眼,均行白内障超声乳化联合IOL单襻或双襻囊袋内悬吊固定术,其中2眼同时行25G微创玻璃体切除术。术后随访6~12mo,观察最佳矫正视力(BCVA)、眼压(IOP)、IOL位置、眼底情况等,记录术中和术后并发症情况。

结果:本组患者均顺利完成手术。术后3mo,BCVA(0.43±0.30)较术前(1.48±0.68)明显改善(t=7.30,P<0.01),IOP均恢复正常(≤21mmHg),IOL均处于正位,无偏心、移位。本组患者术中和术后均未出现严重眼部并发症。

结论:单襻或双襻囊袋内悬吊固定IOL是治疗SL的一种有效的手术方式,不仅可以保持IOL位于正常生理位置、恢复患者视功能,而且经济实用,避免囊袋张力环(CTR)相关的并发症发生。  相似文献   


2.

目的:观察8-0聚丙烯缝线巩膜双联结缝合固定人工晶状体悬吊术在无晶状体眼中的临床效果。

方法:回顾性病例研究。收集2021-01/2022-11于我院行人工晶状体悬吊术的无晶状体患者30例31眼(其中男22例22眼)的临床资料,术中均采用8-0聚丙烯缝线巩膜双联结缝合法固定人工晶状体(AcrySof IQ或Tecnis ZCB00),术后至少随访6 mo,观察所有患者视力、眼压、术后人工晶状体位置和术中术后并发症发生情况。

结果:术前术眼裸眼视力(UCVA,LogMAR)和最佳矫正视力(BCVA,LogMAR)分别为2.53±0.78和0.35±0.26,术后6 mo分别为0.58±0.26和0.36±0.27,手术前后UCVA比较有差异(t=15.408,P<0.01),BCVA比较无差异(t=-1.677,P=0.104)。术中未出现并发症。术后所有人工晶状体位置均居中,出现人工晶状体倾斜3眼,术后发生高眼压2眼、角膜水肿5眼、缝线外露1眼。术后未出现前房积血、玻璃体积血、黄斑水肿、角膜内皮失代偿、低眼压、脉络膜脱离、视网膜脱离、爆发性脉络膜上腔出血、眼内炎等并发症。

结论:8-0聚丙烯缝线巩膜双联结缝合固定人工晶状体悬吊术早期可提高无晶状体患者的术后视力、并发症较少,可作为治疗无晶状体、晶状体脱位、悬韧带异常患者的一种手术方式选择。  相似文献   


3.
陈佳菲  顾朝辉  付燕  李青 《国际眼科杂志》2022,22(10):1757-1760

目的:观察改良四点固定人工晶状体悬吊植入术在无晶状体眼中的有效性及安全性。

方法:前瞻性研究。选2020-10/2021-05于我院行改良四点固定人工晶状体悬吊植入术的无晶状体眼患者32例32眼,平均年龄44.56±8.48岁。观察手术前后裸眼视力(UCVA)、最佳矫正视力(BCVA)、角膜散光、术中及术后并发症。

结果:所有患者平均随访4.84±0.64mo,术前UCVA、(LogMAR)为1.25±0.42,末次随访时为0.5±0.25(P<0.001); 术前BCVA(LogMAR)为0.41±0.19,末次随访时为0.42±0.19(P>0.05); 术前角膜散光为1.17±0.64D,末次随访时为1.20±0.59D(P>0.05)。术中无并发症发生,术后发生低眼压2眼、高眼压1眼、角膜水肿2眼,无前房积血、玻璃体积血、黄斑囊样水肿、角膜内皮失代偿、人工晶状体倾斜或偏心、缝线外露等并发症。

结论:改良四点固定人工晶状体悬吊植入术可显著提高无晶状体眼患者术后视力、未增加额外角膜散光、并发症少。  相似文献   


4.
目的 评价小切口可折叠四襻巩膜固定型人工晶状体 (intraocular lens,IOL)植入术治疗马凡综合征晶状体半脱位患者的临床效果及安全性。方法 回顾性病例分析。12例(21眼)马凡综合征伴透明晶状体半脱位患者行晶状体摘出联合IOL巩膜固定植入联合前段玻璃体切割术。其中,IOL巩膜固定采用了小切口(2.85 mm)、可折叠、一片式、四襻固定型美国博士伦Akreos IOL。观察患者术前、术后的裸眼视力 (uncorrected visual acuity,UCVA)、最佳矫正视力(best corrected visual acuity,BCVA)、眼压、术中及术后并发症。结果 所有患者手术均顺利,术中、术后未见并发症。术后第1天2眼出现一过性眼压升高。术前UCVA 为0.01~0.30 (0.13±0.11),BCVA为0.01~0.60 (0.29±0.17)。随访33~73(57.75±13.78)个月,术后最后一次随访,UCVA为0.10~0.80(0.41±0.22),BCVA为 0.20~1.00(0.70±0.27),两者与术前相比,差异均有统计学意义(均为P<0.05)。IOL位置居中,瞳孔圆。结论 小切口可折叠四襻固定型Akreos IOL悬吊术治疗马凡综合征晶状体半脱位有良好的临床效果及安全性。  相似文献   

5.

目的:探讨巩膜固定囊袋张力环(SFCTR)植入联合晶状体超声乳化吸除加人工晶状体(IOL)植入术治疗外伤性晶状体半脱位的临床疗效。

方法:连续选取2018-12/2023-02行SFCTR植入联合晶状体超声乳化吸除加IOL植入术治疗的外伤性晶状体半脱位患者14例14眼。术后随访行视力、眼压、眼前段照相、超声生物显微镜(UBM)等检查,并记录IOL的位置及术后并发症等情况。

结果:纳入患者均成功植入SFCTR和囊袋内IOL。术后平均随访1.92±1.36 a,末次随访时,UDVA(0.20±0.18 LogMAR)和CDVA(0.16±0.17 LogMAR)均较术前UDVA(1.13±0.56 LogMAR)显著改善(P<0.01),眼压(17.64±3.67 mmHg)较术前(22.00±9.92 mmHg)降低(P<0.05)。随访期间,裂隙灯检查见IOL位于囊袋内,位置居中; UBM检查见CTR和IOL位于囊袋内,囊袋赤道部与睫状突的距离在各个方向相等。

结论:SFCTR植入联合晶状体超声乳化吸除加IOL植入术是治疗外伤性晶状体半脱位的一种微创有效的手术方法。  相似文献   


6.

目的:通过波前像差光路系统探讨人工晶状体(IOL)偏心和倾斜对光学成像质量的影响。

方法:在5.0mm模拟瞳孔直径下,采用实验室搭建的Hartmann-Shack IOL波前像差光路系统检测球面IOL Sensar AR40e、非球面单焦点IOL Tecnis ZA9003、非球面多焦点 IOL Tecnis ZM900分别在偏中心0、0.2、0.4、0.6、0.8mm,向鼻侧和颞侧倾斜5°、10°、15°、20°、25°时对光学成像质量的影响,以高阶像差和调制传递函数(MTF)定量成像质量。

结果:倾斜5°以内时,Tecnis ZA9003 MTF值高于AR40e和Tecnis ZM900,而倾斜5°、10°、15°、20°时三种IOL MTF值有显著差异。Tecnis ZA9003 IOL倾斜角度与彗差呈显著正相关(r=0.842,P<0.001),与球面像差无显著相关性(r=0.229,P=0.241)。偏心0.6、0.8mm时三种IOL MTF值有显著差异(均P<0.001),Tecnis ZM900偏心大于0.4mm时成像质量明显下降。

结论:具有-0.27μm球差的非球面IOL倾斜度小于5°,偏心小于0.4mm时可获得比球面IOL更好的光学成像质量。Tecnis ZM900 IOL偏心大于0.4mm时较球面和非球面IOL的光学成像质量降低。  相似文献   


7.
目的: 比较植入不同襻型人工晶状体(IOL)后囊膜皱褶的发生率,以确定后囊膜皱褶发生的相关风险因素。

方法: 回顾性研究。收集行超声乳化白内障吸除+囊袋内IOL植入术的患者,所植入人工晶状体为两襻三片式IOL(HOYA PY60AD)、四襻一片式IOL(Bausch & Lomb AO)、两襻一片式IOL(AMO Tecnis ZCB00)中任意一种。收集纳入该研究的患者的年龄、性别、眼轴、眼压、人工晶状体类型。术后2d在裂隙灯下评估后囊膜皱褶形成情况。采用logistic回归分析确定后囊膜皱褶发生的风险指标。

结果: 一共收集187例242眼,其中80眼植入HOYA PY60AD IOL,81眼植入Bausch & Lomb AO IOL,81眼植入AMO Tecnis ZCB00 IOL。植入HOYA PY60AD IOL的患眼后囊膜皱褶发生率显著高于植入AMO Tecnis ZCB00 IOL者(56.3% vs 38.3%,P=0.027)。植入Bausch & Lomb AO IOL的患眼后囊膜发生率显著低于植入AMO Tecnis ZCB00 IOL(14.8% vs 38.3%,P=0.001)。多因素logistics回归分析显示人工晶状体类型和眼轴长度是影响皱褶发生的独立风险因素。相较于AMO Tecnis ZCB00 IOL,使用HOYA PY60AD IOL提高后囊膜皱褶发生风险\〖P=0.020,OR(95%CI)=2.145(1.129,4.073)\〗,使用Bausch & Lomb AO IOL降低后囊膜皱褶发生风险\〖P=0.001,OR(95%CI)=0.274(0.127,0.591)\〗; 眼轴越短,后囊膜皱褶发生风险越大\〖P=0.012,OR(95%CI)= 0.669(0.489,0.915)\〗。

结论: 在人工晶状体设计中,晶状体襻是重要考虑因素。相比于AMO Tecnis ZCB00 IOL,HOYA PY60AD IOL更容易出现后囊膜皱褶,Bausch & Lomb AO IOL不容易出现后囊膜皱褶; 眼轴较短的患眼更容易出现后囊膜皱褶。  相似文献   


8.
目的对比植入Akreos AO人工晶状体(intraocular lens,IOL)与Tecnis Z9000 IOL后的波前像差及视功能等指标。方法 82例(100眼)行超声乳化白内障吸出联合IOL植入术的患者,50眼植入Akreos AO IOL(Akreos AO组),50眼植入Tecnis Z9000IOL(Tecnis Z9000组),于术后3个月观察裸眼视力及最佳矫正视力、对比敏感度、波前像差并进行主观问卷调查。结果术后3个月Akreos AO组及Tecnis Z9000组的裸眼视力及最佳矫正视力差异均无统计学意义(均为P>0.05)。Tecnis Z9000组在瞳孔直径为4.0mm、5.0mm、6.0mm下的总体高阶像差及球面像差Z(4,0)均明显低于Akreos AO组(均为P<0.001)。两组在瞳孔直径为4.0mm、5.0mm、6.0mm下的总体三阶像差均方根值差异均无统计学意义(均为P>0.05)。术后3个月,Akreos AO组与Tecnis Z9000组在明视、暗视、明视眩光、暗视眩光下各个空间频率的对比敏感度差异均无统计学意义(均为P>0.05)。术后Akreos AO组患者满意度为95.9%,高于Tecnis Z9000组的81.3%,两组差异有统计学意义(χ2=5.189,P=0.023),术后眩光、光晕及暗处功能视力的不满意率两组差异没有统计学意义。结论虽然Akreos AO IOL与Tecnis Z9000IOL相比保留了患眼的部分球面像差,但植入Akreos AO IOL的患眼仍能够获得满意的术后客观、主观视功能及很高的患者满意度。  相似文献   

9.
何涛  杨秀梅  梁晓磊 《国际眼科杂志》2015,15(12):2146-2148
目的:探讨2.4mm小切口改良Akreos Adapt AO折叠人工晶状体经巩膜睫状沟固定术的的疗效。

方法:选择由外伤、先天、手术等原因造成晶状体后囊破损或悬韧带离断不能正常植入后房型人工晶状体的患者37例37眼,制作角膜缘垂直的“钱包样”板层巩膜瓣,采用博士伦Akreos Adapt AO折叠人工晶状体,利用瑞士产VE2200人工晶状体植入系统,经过透明角膜缘内2.4mm小切口,由双针各带有环形10/0的聚丙烯缝线将人工晶状体固定于睫状沟,埋藏式结扎缝线于板层巩膜瓣内。

结果:所有患者术后植入的人工晶状体居中,裸眼视力均有不同程度的提高。术后3mo视力≥0.8者3眼(8%); >0.4~≤0.6者18眼(49%); ≤0.4者16眼(43%)。术前、术后3mo平均角膜散光分别为1.73±1.22、1.62±1.34D,差异无统计学意义(P>0.05)。术中、术后除1例出现玻璃体积血,2例角膜水肿外,未见其它严重并发症。所有患者均无固定线结暴露。

结论:2.4mm微创小切口行Akreos Adapt AO折叠人工晶状体睫状沟固定术,手术切口小、晶状体悬吊稳固、居中性好、视力恢复满意、术后角膜散光变化小。固定线结扎方法具有线结埋藏无暴露并同时关闭巩膜瓣切口的特点,操作步骤简捷、手术并发症少、实用有效可行。  相似文献   


10.
目的 对两种不同球差非球面人工晶状体(IOL)植入术后高阶像差进行对比研究.方法选取我院2011年6月至2012年6月行白内障超声乳化吸除联合非球面IOL植入术的白内障患者中17例(31只眼)进行回顾性研究,随访时间3个月以上,植入IOL分别为Akreos Adpt AO零球差非球面IOL(美国Bausch &Lomb公司)和Tecnis ZCB000负球差非球面IOL(美国AMO公司).对两组术后3个月波前像差进行测量对比.结果 Akreos组垂直慧差显著低于Tecnis组(P<0.05);两组之间水平慧差无统计学差异(P>0.05);总球差Akreos组明显高于Tecnis组(P<0.05).结论不同球差非球面IOL植入术后各种不同的高阶像差各有优势,如何判断与把握两种非球面IOL的选择,需要更加深入的研究.  相似文献   

11.
Pan-Pan Ye  Xia Li  Ke Yao 《国际眼科》2013,6(3):300-306
AIM:To evaluate the visual function after bilateral implantation of aspheric diffractive multifocal Tecnis ZMA00, aspheric monofocal ZA9003 versus spherical monofocal Akreos Adapt intraocular lenses (IOLs).METHODS:Tecnis ZMA00, Tecnis ZA9003 or Akreos Adapt IOLs were bilaterally implanted in 180 eyes from 90 patients. The following parameters were assessed 3 months postoperatively:monocular and binocular uncorrected visual acuity (UCVA) and distance-corrected visual acuity (DCVA) for distance, intermediate and near, spherical aberration (SA), contrast and glare sensitivity, near point refractive power, uncorrected and best-corrected near stereoscopic acuity (NSA). Patient satisfaction was assessed by a questionnaire.RESULTS:Three months postoperatively, the monocular and binocular UCVA and DCVA at near of Tecnis ZMA00 were significantly better than other two groups. The mean SA for 5.0mm optical zone in Tecnis ZMA00 and Tecnis ZA9003 was significantly lower than that in Akreos Adapt. Mean contrast sensitivity and glare sensitivity were better for Tecnis ZA9003 group than for other two groups. Patients with Tecnis ZMA00 had higher monocular and binocular near point refractive power and uncorrected NSA than monofocal groups. The patients in Tecnis ZMA00 had higher mean values for halo compared with other two groups.CONCLUSION:Tecnis ZMA00 provided better near VA and uncorrected NSA and higher near point refractive power than monofocal IOLs and patients were spectacle independent. The IOLs with Tecnis aspheric design improved contrast and glare sensitivity. Patients with Tecnis ZMA00 reported more disturbances on visual phenomena of halo.  相似文献   

12.
非球面与球面人工晶状体植入术后对比敏感度的比较   总被引:1,自引:0,他引:1  
目的观察非球面人工晶状体(IOL)和球面IOL植入术后在视力相同的情况下其对比敏感度的差异。方法收集行超声乳化联合IOL植入术的年龄相关性白内障患者49例(60眼),其中植入非球面IOL Tecnis ZA9003者24例30眼,植入球面IOL Sensar AR40e者25例30眼,所有病例术后裸眼LogMAR视力均〉0.1。术后3个月时采用CSV-1000对比敏感度测试仪分别测量明视、暗视和眩光状态下的对比敏感度,用F.A.C.T对比敏感度表测量近距离对比敏感度。结果在明视和暗视状态下的对比敏感度,非球面IOL组均高于球面IOL组,两组在空间频率6、12、18周/度时的差异均有统计学意义(P〈0.05);暗视眩光状态下的对比敏感度,非球面IOL组高于球面10L组,两组在各空间频率的差异均有统计学意义(P〈0.05)。F.A.C.T对比敏感度测试卡测得的对比敏感度,非球面IOL组高于球面IOL组,两组在各空间频率的差异均有统计学意义(P〈0.05)。结论在传统的视力表检查视力正常和相同的情况下,非球面IOL植入术后较球面IOL植入术后患眼具有较好的对比敏感度,提示非球面IOL可以提高功能视力。  相似文献   

13.
目的:探讨不同手术方式治疗不同程度脱位晶状体的临床效果及安全性。方法:回顾性系列病例研究。收集2018-11/2019-05浙江中医药大学附属第一医院晶状体不全脱位合并白内障的患者11例11眼(男9例,女2例),年龄46~76(60.73±10.63)岁。其中外伤性白内障10眼,原因不详者1眼。根据脱位程度采用不同的手术方式辅助人工晶状体植入,4眼晶状体脱离范围大于270°行人工晶状体悬吊术。4眼脱离范围180°~270°行张力环植入,虹膜拉钩巩膜固定。3眼脱离范围小于180°行5-0聚丙烯线植入囊袋辅助人工晶状体植入,虹膜拉钩巩膜固定。术中视玻璃体脱出情况行前段玻璃体切除。收集患者术前术后视力、眼压。结果:所有眼球均Ⅰ期植入人工晶状体。术后视力显著提高,术前最佳矫正视力从0.77±0.26提升到0.35±0.28。术后患者眼压从24.33±13.55mmHg下降到13.85±3.80mmHg。所有患者无术中并发症发生。结论:晶状体不全脱位合并白内障的手术治疗过程中,个性化的手术方案及灵活的治疗措施,可以使得白内障手术安全、有效地进行。  相似文献   

14.
目的 评价术前角膜球差大于等于0.33μm与小于0.33μm的年龄相关性白内障患者在植入Tecnis ZA9003非球面人工晶状体术后视觉质量.方法 对48例(60只眼)年龄相关性白内障患者术前1d利用iTrace视觉功能分析仪测量6.0mm直径的角膜球差,将角膜球差大于等于0.33μm设为观察组,小于0.33μm者为对照组,所有患者均行3.2mm透明角膜切口的超声乳化白内障吸除联合TecnisZA9003非球面IOL入术,术后3个月观察患者的裸眼视力、最佳矫正视力、对比敏感度及3.0mm和6.0mm瞳孔直径下的全眼像差及5、10、15、20、25、30周(cycles per degree,cpd)空间频率下的调制传递函数.结果 术前6.0mm直径的角膜球差,观察组(0.362±0.075)μm大于对照组(0.231±0.056)μm,差异有统计学意义(t=7.694,P=0.000).术后3个月,6.0mm瞳孔时的全眼球差观察组(0.088±0.046)μm大于对照组(-0.038±0.062)μm,差异有统计学意义(t=8.939,P=0.000).两组患者的裸眼视力及最佳矫正视力差异均无统计学意义(P>0.05).观察组的对比敏感度值优于对照组,在暗视(3cpd)及暗视加眩光(1.5、6cpd)下两组差异均有统计学意义(P<0.05).观察组在3.0mm和6.0mm瞳孔直径下各频段的调制传递函数值均高于对照组(P<0.05).结论 非球面人工晶状体植入术后预留少量的正球差可能会提高患者的视觉质量.  相似文献   

15.
Dong-Mei Qi  Shu-Jia Huo  Tao Yu 《国际眼科》2023,16(11):1789-1793
AIM: To compare the clinical outcomes between two approaches for sutureless scleral-fixated intraocular lens (SFIOL) in children with Marfan syndrome (MFS). METHODS: The study included 15 children (26 eyes) with lens subluxation due to MFS. These children underwent lensectomy, anterior vitrectomy, and sutureless SFIOL. According to the position of placement of intraocular lens (IOL) haptics, two study groups were reviewed for best corrected visual acuity (BCVA) and postoperative complications: group A, 14 eyes with haptics fixated at 2.0 mm from the limbus; group B, 12 eyes with the haptics fixated at 2.5 mm from the limbus. RESULTS: The mean axial length for all patients was 25.66±2.35 mm. Postoperative BCVA in logMAR were significant improved in both groups (0.77±0.32 to 0.17±0.12 in group A, 0.66±0.25 to 0.24±0.12 in group B, both P<0.001) while no significant difference between two groups (P>0.05). Pupillary capture was main postoperative complication, occurring between 3d and 18mo. It occurred in 7 eyes in group A and one eye in group B (P=0.02). CONCLUSION: Sutureless SFIOL is an effective treatment approach for lens subluxation in children with MFS. Pupillary capture is the main postoperative complication. Fixated IOL haptics at 2.5 mm from the limbus can reduce the occurrence of pupillary capture.  相似文献   

16.

目的:观察隐形锚钩式巩膜层间人工晶状体固定术的临床效果。

方法:前瞻性非对照性病例研究。选取2019-01/2020-12我院收治的无晶状体、人工晶状体脱位或晶状体脱位患者19例19眼,所有患者均接受锚钩式人工晶状体巩膜层间固定植入手术。观察手术前后最佳矫正视力(BCVA)、裸眼视力(UCVA)、角膜内皮细胞密度、术后人工晶状体位置有无倾斜和并发症。

结果:术前和术后1 mo ,UCVA(LogMAR)为1.06±0.63和0.40±0.26(P<0.01),BCVA(LogMAR)为0.27±0.51和0.06±0.15(P=0.09),角膜内皮细胞密度为2406±625和2004±759 cells/mm2(P=0.13)。术后1d房水闪辉2级或以上3眼,角膜后弹力层皱褶2眼,一过性眼压升高2眼。随访24 mo均未发生人工晶状体脱位。

结论:锚钩式人工晶状体巩膜层间固定技术,组织间线头顺行进入-逆向固定,类似锚钩原理,达到了良好的人工晶状体稳定性和视觉效果。  相似文献   


17.
Purpose:  To evaluate the posterior capsule opacification (PCO) rates in three different modern standard intraocular lenses (IOL) and analyse the related cost. Methods:  Retrospective study of medical records from 1527 patients who underwent uneventful cataract surgery by phacoemulsification with posterior chamber implantation of either AcrySof SN60 (n = 375), Akreos Adapt (n = 350) or Tecnis Acryl IOL (n = 801). All surgeries were performed by the same surgeon using the same surgical technique and equipment. Primary end‐point was neodymium:yttrium‐aluminium‐garnet (Nd:YAG) capsulotomy for visual impairment secondary to PCO. Cost of IOL material and Nd:YAG capsulotomy for PCO was then evaluated and compared between the IOLs. Results:  Mean follow‐up was 41.5 months, and the only statistically significant variable of developing PCO was IOL type and individual follow‐up time. Nd:YAG capsulotomy was performed in 7.47% in the AcrySof group, 17.71% in the Akreos group and 3.75% in the Tecnis group. Average cost for Nd:YAG capsulotomy per surgery was €18.75 in the AcrySof SN60 group, €44.25 in the Akreos Adapt group and €9.25 in the Tecnis Acryl group. The combined cost of cataract surgery and PCO treatment was €9.81 higher in for the Akreos Adapt group than the other two combined. Conclusions:  This retrospective study shows that the risk of PCO and Nd:YAG capsulotomy is significantly higher in hydrophilic Akreos IOL compared with both AcrySof and Tecnis hydrophobic IOLs. The increased risk of PCO in the hydrophilic IOL is related to higher total average costs for cataract surgery.  相似文献   

18.
目的评价复色光环境下球面、非球面、toric IOL的纵向色差。方法实验研究。在Zemax光学设计软件中建立Hwey-Lan Liou模型眼,使用光线追迹法计算SN60AT IOL、YA60BB IOL、Tecnis ZA9003 IOL和3种型号toric IOL的纵向色差。使用Originpro 7.5(美国OriginLab公司)制图软件绘图。结果复色强光环境下SN60AT IOL的纵向色差是2.35 D,YA60BB IOL是2.06 D,Tecnis ZA9003 IOL是1.57 D。3种型号toric IOL的纵向色差是2.34 D,材料色散系数小的IOL有较小的纵向色差;球面SN60AT和T3、T4、T5 toric IOL有相同的纵向色差;暗光环境的纵向色差大于强光环境。结论Abbe数越大,IOL的纵向色差越小。低散光度的toric IOL与球面IOL有相同的纵向色差。  相似文献   