首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 750 毫秒
1.
2.
3.
4.
Aim: Previously, glutamine‐enriched enteral nutrition in very low birth weight infants (VLBW) decreased the incidence of atopic dermatitis at age 1 year. The aim of this study was to determine whether this effect is related to changes in intestinal bacterial species that are associated with allergy, such as bifidobacteria, clostridium histolyticum, clostridium lituseburense (Chis/lit group) and Escherichia coli at age 1 year. Methods: Eighty‐nine infants were eligible for this follow‐up study, conducted at a Tertiary care hospital. Bifidobacteria, Chis/lit group and E. coli were measured by fluorescent in situ hybridization in faecal samples collected at age 1 year. Information on allergic and infectious diseases was previously determined by questionnaire. Results: Seventy‐two of 89 (81%) infants were participated. Prevalence of all studied species was not different between glutamine‐supplemented and control groups. Allergic infants were less frequently colonized with bifidobacteria than nonallergic infants (p = 0.04). Between neonatal period and 1 year, prevalence of bifidobacteria was increased (p < 0.001), of Chis/lit group was unchanged (p = 0.84), and of E. coli was decreased (p < 0.001). Conclusion: The beneficial effect of glutamine‐enriched enteral nutrition on the incidence of atopic dermatitis in the first year of life in VLBW infants is not related to changes in bifidobacteria, Chis/lit group or E. coli. Allergic VLBW infants are less frequently colonized with bifidobacteria compared to nonallergic VLBW infants.  相似文献   

5.
Background: The purpose of this study was to determine the prevalence of persistent neurodevelopmental sequelae in 1‐year‐old infants after open heart surgery for congenital heart disease, using the Bayley Scales of Infant Development second edition (BSID‐II). A secondary objective was to confirm the applicability and usefulness of the BSID‐II in Japanese infants. Methods: Thirty‐nine infants who underwent repair of a ventricular septal defect before 6 months of age and 108 normal Japanese infants at 1 year of age were assessed using the BSID‐II. Results: In normal infants, scores on the Mental Development Index and the Psychomotor Development Index components of the BSID‐II ranged from borderline retardation to very superior following a normal distribution similar to those obtained for US controls. No problems were encountered, either in translation or in following the instructions when the BSID‐II was used to evaluate the 1‐year‐old Japanese infants. On the other hand, the mean scores on the Mental Development Index and the Psychomotor Development Index were significantly lower in Japanese patients than in normal Japanese infants, particularly for gross motor development (P < 0.001). Linear regression analysis showed that a longer intensive care unit stay was associated with impaired cognitive development at 1 year of age (P= 0.03). Conclusions: Neurodevelopmental functions in 1‐year‐old infants with congenital heart disease were lower than those in normal infants, especially for gross motor function using the BSID‐II. One risk factor that correlated with neurodevelopmental sequelae was the length of intensive care unit stay.  相似文献   

6.
ABSTRACT. The syndrome of infant botulism was first recognised in late 1975 and the majority of cases reported have been from the United States of America. One case has been reported from the United Kingdom and one from Canada.
A three-month-old male infant from Victoria, Australia presented with constipation, marked hypotonia, limb weakness, ptosis, facial weakness and inability to suck and swallow. These abnormalities resolved and he returned to normal over the ensuing months.
A diagnosis of infant botulism was confirmed after the isolation of Clostridium botulinum type B from the faeces.
Infant botulism has now been recognised in four different countries and it is likely than with increasing awareness of this striking clinical syndrome, more cases will be identified.  相似文献   

7.
Since Kangaroo Mother Care (KMC) was developed in Colombia in the 1970s, two trends in clinical application emerged. In low income settings, the original KMC model is implemented. This consists of continuous (24 h/day, 7 days/week) and prolonged mother/parent–infant skin‐to‐skin contact; early discharge with the infant in the kangaroo position; (ideally) exclusive breastfeeding; and, adequate follow‐up. In affluent settings, intermittent KMC with sessions of one or a few hours skin‐to‐skin contact for a limited period is common. As a result of the increasing evidence of the benefits of KMC for both infants and families in all intensive care settings, KMC in a high‐tech environment was chosen as the topic for the first European Conference on KMC, and the clinical implementation of the KMC model in all types of settings was discussed at the 7th International Workshop on KMC. Kangaroo Mother Care protocols in high‐tech Neonatal Intensive Care Units (NICU) should specify criteria for initiation, kangaroo position, transfer to/from KMC, transport in kangaroo position, kangaroo nutrition, parents’ role, modification of the NICU environment, performance of care in KMC, and KMC in case of infant instability. Conclusion: Implementation of the original KMC method, with continuous skin‐to‐skin contact whenever possible, is recommended for application in high‐tech environments, although scientific evaluation should continue.  相似文献   

8.
9.
10.
11.
12.

Objective

To measure levels of parenting stress and postnatal depression in mothers of very preterm infants in comparison with mothers of infants born at term is the objective of this study. The study also aimed to explore factors associated with parenting stress in the mothers of the preterm infants.

Methods

One hundred and five mothers who delivered 124 babies at ≤ 30 weeks gestation were enrolled together with 105 term mothers who delivered 120 babies. At one year of age (corrected for prematurity for the preterm cohort), the mothers completed the Parenting Stress Index Short Form (PSI), the Edinburgh Postnatal Depression Scale (EPDS) and the Short Temperament Scale for Toddlers. The infants had neurodevelopmental assessment. The preterm and term groups were compared.

Results

Questionnaires were completed by 101 of the preterm mothers and 98 of the term mothers. The mean PSI Total Stress score was significantly higher for the preterm mothers (70.28 vs 64.52, p = 0.022), with 19% of the preterm group and 9% of the term group having high scores (p = 0.038).There was no group difference on the EPDS or measures of temperament, with disability being greater in the preterm infants. For the preterm group, maternal depression and infant temperament were independent predictors of Total Stress scores on multivariate analysis.

Conclusions

Parenting stress in mothers of preterm infants at one year of age is significantly greater than that found in mothers of term infants. For preterm mothers, symptoms of depression and infant temperament are independent risk factors for higher levels of parenting stress.  相似文献   

13.
14.
Background: Ventilator frequency is one of the determinants of tidal volume delivery during high‐frequency ventilation. Clinicians increasingly use data on ventilator displays to inform their decisions. Aim: To measure the frequencies delivered by the Dräger Babylog 8000plus ventilator when used in high‐frequency mode. Methods: Ventilator waveforms using a test lung were recorded at the full range of settings 5–20 Hz using Spectra software at 1000 Hz. The changes in frequency produced by a 1‐ Hz change in set frequency were calculated. Actual and displayed frequencies were compared. Results: For settings up to 12 Hz, median (range) difference between set and delivered frequencies was 0 (?0.4 to +0.1) Hz. Above 12 Hz, delivered frequency varied by ?0.3 (?1.9 to +0.3) Hz. For 1‐ Hz changes in frequency settings, in the range 5–12 Hz, 1‐ Hz changes produced a change in delivered frequency of 1.0 (0.6–1.4) Hz. Above 12 Hz, the corresponding changes were 0.7 (0–2.9) Hz. The ventilator displays the set frequency during operation rather than the delivered frequency. Conclusion: At 12 Hz and below, the differences between set and delivered frequencies were relatively small compared with those at 13 Hz and higher. Above 13 Hz, the difference between set and delivered frequencies was up to 2.9 Hz. Some frequency setting changes did not result in a change in delivered frequency.  相似文献   

15.
16.
17.
18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号