首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 187 毫秒
1.
目的探讨128层螺旋CT智能最佳管电压(CAREkV)技术对腹部扫描辐射剂量及其图像质量的影响。方法选择2013年10月至12月90例行CT常规全腹部检查患者,其中男性50例,女性40例;年龄46~75岁,平均年龄61.6岁。随机分为3组:A组30例,扫描管电压为120kV,360mA;B组30例,扫描管电压为120kV和电流CAREDose 4D技术;C组30例,扫描管电压为CAREkV技术和电流CAREDose4D技术;3组其他扫描参数和图像重建参数均相同。由2名高年资放射科医师对3组图像质量进行评价。测量肝门层面肝实质的CT值及图像噪声(SD),比较各组信噪比(SNR)、对比噪声比(CNR)、平均容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效剂量(ED)。结果图像主观评价A组得分3.73,B组3.50,C组3.60,3组差异无统计学意义(P0.05)。CNR,A组0.49,B组0.38,C组0.50;SNR,A组3.53,B组2.81,C组3.31;A组与C组CNR和SNR比较,差异无统计学意义(P0.05),B组与A组、C组比较,差异均有统计学意义(P0.05)。A、B、C 3组CTDIvol、DLP比较,差异有统计学意义(P0.05)。A、B、C 3组ED分别为(13.25±1.3)mSv、(7.57±1.9)mSv、(6.36±1.6)mSv,两两之间差异均有统计学意义(P0.05)。结论 CARE kV技术能够根据患者个体差异自动选择kV及mA,在保证图像质量的同时,可以有效地减低辐射剂量。  相似文献   

2.
目的 探讨b值的选取对DTI测量指标和图像质量的影响,从而获得最佳b值。方法随机招募20例健康志愿者行DTI成像,b值的选择为0、200、400、600、800、1000s/mm^2,弥散梯度方向为6,分别测量ADC值、FA值,SNR、CNR,对ADC图进行评分,分析不同b值时的变化规律。结果5组b值获得的肾实质、皮质、髓质的ADC值及SNR值比较具有统计学意义(F值为1846.65、368.93、207.80和951.93,P〈0.05),随着b值的增大,ADC值变小,SNR值变小。不同b值的肾实质、皮质、髓质的FA值及CNR值比较均不具有统计学意义(F值为0.98、1.07、1.14和1.13,P〉0.05)。相同b值时皮、髓质ADC值和FA值比较均具有统计学意义(P〈0.05)。ADC图得分随着b值的增大,图像质量变差。b值取0、800s/mm^2时,ADC图的图像质量具有诊断意义,但皮髓质分辨不清晰。b值与肾实质ADC值、SNR上呈负相关(r=-0.980和-0.974,P〈0.05),而与FA值、CNR无相关(r=-0.156和-0.152,P〉0.05)。结论b值为600s/mm^2的图像质量较好,皮髓质差异容易分辨,适合于肾脏的研究。  相似文献   

3.
目的 探讨等中心扫描对降低冠状动脉多层螺旋CT血管成像(MSCTA)辐射剂量的价值。方法 采用前瞻性随机对照研究方法。纳入广东省中医院珠海医院2016年11月—2018年4月144例行冠状动脉MSCTA检查患者,将患者按随机区组法分为A、B、C、D 4组,每组36例。A组采用常规扫描定位,电流为智能毫安;B、C、D组采用等中心位置扫描,电流分别为智能毫安、智能毫安的90%、智能毫安的80%。4组扫描管电压均为120 kV。比较4组患者冠状动脉MSCTA图像的客观图像质量噪声、信噪比(SNR),主观质量评分比及辐射剂量(ED),对直径>1.5 mm的血管节段采用冠状动脉15分段法评分,用以评价主观图像质量。客观噪声方面,4组重建图像中的主支气管选择,感兴趣区(面积约15.0 mm2),测量其标准差值作为噪声值,SNR为其CT值/标准差。结果 MSCTA图像分析显示,以D、A、C、B组为序,噪声依次降低(分别为15.09±2.97、2.68±2.47、2.57±2.29和2.45±4.36),SNR依次升高(分别为63.74±19.78、78.64±14.66、78.66±14.84和79.66±22.90);D组与A、B、C组两两比较,噪声高而SNR低,差异均有统计学意义(P值均<0.05);A、B、C组间噪声及SNR两两比较,差异均无统计学意义(P值均>0.05)。4组冠状动脉图像质量主观评分优良率98.9%(1 939/1 960),4组间比较差异均无统计学意义(P值均>0.05);A、B、C、D辐射剂量依次降低,分别为(3.39±1.39)mSv、(2.89±1.21)mSv、(2.56±1.05)mSv,(2.14±0.87)mSv,其中A组明显高于C、D组,B组高于D组,差异均有统计学意义(P值均<0.05)。结论 在不降低冠状动脉成像质量的情况下,等中心扫描能降低冠状动脉MSCTA的辐射剂量。  相似文献   

4.
目的探讨在行腹部CT血管成像(CTA)检查时图像质量与辐射剂量的关系,以求获得最高的质量剂量比。方法收集2008年3月至2012年4月在本院行腹部CTA的患者270例,随机分成管电压、管电流及螺距组,每组90例。管电压组分140、120、100kV3级,每级30例;管电流组分400、300、200mA3级,每级30例;螺距组分0.5、1、1.53级,每级30例。采用64排螺旋CT扫描从膈顶2cm到腹主动脉髂总动脉分叉处,在腹主动脉近端设置触发兴趣区。当造影剂CT值达到120HU时,触发扫描并记录辐射剂量。把动脉期容积数据发送到Vitrea工作站进行最大密度投影(MIP)、容积再现(vRT)处理,通过血管的显影、饱满度、整体性、对比度、伪影等的综合得分来评估图像质量,进而对比各组的图像质量与辐射剂量。结果管电压组中随着管电压从140kV下降到100kV,腹部CTA的图像质量与辐射剂量均下降,辐射剂量的下降程度更大(P〈0.05)。120kV与140kV的图像质量均在优良以上,差异没有统计学意义(P=0.19),100、120kV管电压下的图像质量比140kV时分别下降41.3%(P〈0.05)、8.7%。患者采用的辐射剂量从140kV下降到100kV逐渐下降,3级管电压组之间辐射剂量的差异有统计学意义(均P〈0.05),120kV的图像质量剂量比最高。管电流组中,随着管电流从400mA下降到200mA,腹部CTA的图像质量与辐射剂量同时下降,但辐射剂量的下降程度更大(P〈0.05),300mA与400mA的图像质量均在优良以上,差异没有统计学意义(P=O.21),200、300mA管电流下的图像质量比400mA时下降了40.4%(P〈0.05)、10.6%。患者采用的辐射剂量从400mA到200mA逐渐下降,3级管电流组之间辐射剂量的差异有统计学意义(均P〈0.05),300mA的质量剂量比最高。螺距组中,随着螺距从0.5上升到1.5,腹部CTA的图像质量和辐射剂量同时下降,辐射剂量下降程度更大(P〈0.05)。螺距1与0.5的图像质量均在优良以上,差异没有统计学意义(P=0.20),螺距1.5的图像质量比螺距0.5、1时下降了50.O%(P〈0.05)、10.9%。在患者采用辐射剂量上,螺距0.5、1、1.53级螺距组之间辐射剂量的差异有统计学意义(均P〈0.05),1的质量剂量比最高。结论适当的降低管电压、管电流及增加螺距,图像质量虽有所下降,但能满足诊断要求,而辐射剂量下降的幅度更大,这有利于x线的全民防护。  相似文献   

5.
目的 探讨低剂量双源CT扫描在腹部三期增强检查中的应用效果。方法 回顾性分析我院140例疑似肝癌患者的临床资料,患者均行双源CT腹部三期增强检查,根据增强扫描中能量和碘海醇剂量的不同将其分为A1组(低能量低剂量,80 keV、270 mgI/mL)37例、A2组(低能量高剂量,80 keV、350 mgI/mL)35例、B1(高能量低剂量,140 keV、270 mgI/mL)40例、B2组(高能量高剂量,140 keV、350 mgI/mL)28例。采用图像质量主观评分和客观评分[信噪比(SNR)]评估各组图像质量,计算各组图像的有效照射剂量[剂量长度乘积(DLP)及有效剂量(ED)]。以病理检查结果为金标准,评估低剂量双源CT腹部三期增强扫描诊断肝癌的价值。结果 各组图像可清晰显示血管及脏器组织,均达到诊断要求。各组在动脉期和门静脉期的图像质量主观评分比较差异无统计学意义(P>0.05)。各组动脉期和门静脉期腹主动脉腹腔干、腹腔动脉干、肠系膜上动脉、门静脉主干图像SNR比较,差异具有统计学意义(P<0.05),且A1组所得图像SNR明显高于其他组(P<0.05)。...  相似文献   

6.
目的:探讨CARE Dose 4D技术在鼻咽癌放疗定位中的应用价值。方法:将60例拟放疗的鼻咽癌患者随机分为A组和B组,每组30例。A组管电压120 kV固定300 mAs行常规扫描,B组管电压120 kV并开启CARE Dose 4D设置预设值为500 mAs进行扫描。在这两种不同扫描方式下扫描CIRS 064M电子密度模体,验证CT-RED转换曲线是否有差异。客观评价两组图像的噪声(SD)、信噪比(SNR)、对比噪声比(CNR)、GTV的CT值、剂量长度乘积(DLP)、容积CT剂量指数(CTDIvol)及有效辐射剂量(ED)。并由两位高年资医师对图像进行主观评分。结果:两种扫描方式下,CT值及CT-RED转换曲线无明显差异,保证了靶区剂量计算的精确性;B组与A组比较CTDIvol降低35%,DLP、ED均降低43%,差异有统计学意义(P<0.001);客观评价中两组图像的SNR、CNR、GTV的平均CT值之间的差异无统计学意义(P>0.05)。两组图像在三角肌平面,A组SD高于B组,差异有统计学意义(t=30.809, P<0.001);两组图像主观评价有显著性差异(z=-2.445, P<0.05)。A组图像中由于肩部横断面内颈部淋巴引流区噪声较大,对医生勾画该层面的靶区造成了一定困扰,从靶区勾画角度来说,B组图像要优A组。结论:在鼻咽癌放疗定位中应用CARE Dose 4D技术是可行的,可提高图像质量,同时大幅降低患者的有效辐射剂量。  相似文献   

7.
目的:探讨小剂量低辐射手动触发技术在CT肺动脉血管成像(CTPA)中的应用价值。方法:90例疑似肺栓塞(PE)患者随机分为常规组(n=45)和小剂量组(n=45),常规组行常规模式(120 kV,50 mL对比剂)的CTPA扫描,小剂量组行低管电压小剂量对比剂(80 kV或100 kV,30 mL对比剂)的CTPA扫描。比较两组图像质量及辐射剂量。结果:CT值和SNR在两组肺动脉主干和右肺S10段肺动脉中比较均无统计学意义(P>0.05),而CNR在两组肺动脉主干和右肺S10段肺动脉中比较均无统计学意义(P>0.05),在右肺S1段肺动脉中,常规组的CNR则显著高于对照组,差异具有统计学意义(P<0.05)。两位观察者对图像质量分析有着极好的一致性(Kappa=0.865, P<0.001)。常规组CTDIvol、DLP、ED值分别为(8.89±1.96) mGy、(296.5±78.4) mGy[?cm、(4.45±1.76) mSv,均明显高于小剂量组的(3.12±0.68) mGy、(99.6±17.3) mGy[?cm、(1.09±0.27) mSv(P<0.05),小剂量组的ED值相比常规组降低约76%。结论:小剂量低辐射手动触发技术应用于CTPA中是可行的,在获取满足诊断需求图像质量的同时,能够有效减少辐射剂量及对比剂用量,提高检查安全性。  相似文献   

8.
目的探讨体质量指数(BMI)不同的患者冠状动脉CT血管成像(CCTA)扫描模式的优选方案。方法前瞻性研究。选取2022年4—8月淮北市人民医院影像科行CCTA检查的心前区不适患者180例, 其中男93例、女87例, 年龄26~82(55.4±11.5)岁, 体质量指数(BMI)≥18.5 kg/m2。180例中, 18.5 kg/m2≤BMI<28.0 kg/m2者和BMI≥28.0 kg/m2者各90例, 分别纳入对照组与观察组, 采用随机法分别分成A1、B1、C1亚组和A2、B2、C2亚组, 每个亚组30例。其中A1、A2组采用常规管电压、管电流扫描模式, B1、B2组采用低管电压、正常管电流扫描模式, C1、C2组采用低管电压、高管电流扫描模式, 进行CCTA扫描, 以及轴位多平面重组(MPR)、曲面重建(CPR)和薄层最大密度投影(MIP)重组。采用冠状动脉分段评分法对图像质量进行主观评价;测量升主动脉根部的CT值和图像噪声(SD), 计算并比较各组的图像信噪比(SNR), 以及左冠状动脉主干、各分支近段的对比噪声比(CNR)等定量指标, 对图像质量进行客观评价;计算并比...  相似文献   

9.
目的:探讨基于原始数据迭代算法(Sonogram Affirmed Iterative Reconstruction,SAFIRE)的二代双源CT单能成像技术在腹部血管(门静脉)的成像质量评价。方法:对符合临床要求行上腹部增强CT扫描,且门静脉期行双能扫描的40例病患纳入研究。采用双能量单能谱软件得出门静脉主干对比信噪比(Contrast to Noise Ratio,CNR)能量变化曲线,得出最佳单能量点的单能图像。将扫描得到的门脉期图像数据进行3组不同函数的回顾重建:A组为最佳单能量+滤波反投射(FBP);B组为最佳单能量+迭代SAFIRE-3级;C组为双能两球管(80 k V和140 k V)扫描完成后,自动加权生成的管电压为120 k V的门脉图像作为常规对照组,即120 k V+FBP。在工作站上分别完成门静脉血管重建的最大密度投影,容积再现(Volume Rendering,VR)和多平面重建,并在门脉分支中心层面测量门静脉主干,肝实质结构的CT值和图像噪声值,并计算CNR值。由两位高年资放射科医生对门脉图像进行评价评分。结果:A、B、C三组的门脉CT值分别为(192.31±37.88)HU、(189.89±37.42)HU和(152.54±27.58)HU;CNR值分别为5.83±1.28、8.16±1.96和2.57±1.27。A,B两组门脉图像质量明显高于C组,有统计学差异(P0.01)。结论:双源双能CT在门脉成像中,单能量成像与常规成像方式相比,能够大大提高图像质量,可以应用于临床。  相似文献   

10.
【摘要】目的:探讨双源炫速CT-flash低剂量扫描技术及低对比剂注射方案结合迭代重建CT血管成像在婴幼儿先天性心脏病诊断中的价值。方法:收集拟诊断为先天性心脏病行心脏血管扫描的患者86例,随机分为实验组(44例)与对照组(42例),分别采用双低扫描方案与常规扫描方案,记录两组患者的对比剂用量,容积CT剂量指数和剂量长度乘积,计算有效辐射剂量(ED);由两位经验丰富的放射医师独立诊断并采用4分法对图像质量进行评估,对结果一致性评价采用Kappa检验;测量两组图像的信噪比和对比度噪声比(CNR);以数字减影血管造影或手术结果作为金标准,比较两种扫描方法的诊断价值。结果:实验组患儿的ED为(0.30±0.16) mSv,对照组患儿ED为(0.97±0.34) mSv,差异有统计学意义(P<0.01);对比剂注射剂量分别为(10.01±1.87)和(16.04±3.17) mL,差异有统计学意义(P<0.05);实验组图像质量评分(3.40±0.57)分,优于对照组(2.90±0.89)分,两组图像均符合诊断要求,差异有统计学意义(P<0.05);两组图像CNR差异有统计学意义;实验组与对照组的诊断敏感度分别为97.4%和97.9%,特异度分别为98.7%和97.7%,诊断准确率分别为98.3%和97.8%,差异无统计学意义。结论:双低扫描方案结合迭代重建技术可大大降低婴幼儿患者的CT辐射剂量与对比剂注射剂量,图像质量优于常规扫描方案,且诊断准确率高,适合在临床扫描中推广运用。  相似文献   

11.
Objective  L5–S1 instabilities can be fixated using minimally invasive presacral approach. The close relationship between the sacrum and neurovascular as well as intestinal structures may complicate the procedure during this approach. This requires knowledge regarding the normal anatomy of the presacral area to avoid the iatrogenic injuries. The aim of this study was to measure the distance between the sacrum and the structures anterior to it. Materials and methods  The measurements were performed on ten cadavers fixed with formaldehyde and ten MR imaging studies on individuals without any pathology in the presacral area. The distances between the sacrum and the presacral structures (i.e., middle and lateral sacral arteries, sympathetic trunks, internal iliac arteries and veins, and colon/rectum) were measured. Results  Cadaver study showed that the middle sacral artery was located on the right side in 55.0%, on the left side in 31.7%, and on the midline in the 13.3% of cases. The distance between the sacral midline and middle sacral artery was found to be 8.0 ± 5.4, 9.0 ± 4.9, 8.7 ± 6.0, 8.6 ± 6.4, and 4.7 ± 5.0 mm at the levels of S1–2, S2–3, S3–4, S4–5, and S5–coccyx, respectively. The distance between the sacral midline and the sympathetic trunk ranged between 22.4 ± 5.8 and 9.5 ± 3.2 mm in different levels between S1 and coccygeal level. The study also showed that the distance between the posterior wall of the intestine (colon/rectum) and the ventral surface of the sacrum can be as close as 11.44 ± 7.69 mm on MR images. Conclusion  This study showed that there was close distance between the sacral midline and the structures anterior to it. The close relationships, as well as the potential for anatomical variations, require the use of sacral and presacral imaging before presacral approach.  相似文献   

12.
张茜  刘影 《解剖与临床》2014,19(2):97-101
目的 应用高分辨MRI观察直肠肠壁及其周围解剖细节,为直肠癌的临床诊断和治疗提供解剖参数和依据。 方法 收集60名健康人及20例直肠癌患者的盆腔多序列参数MRI;两位高年资医师行双盲法阅片,对20例直肠癌患者行术前T分期并与术后病理对照,分析准确率;统计分析60名正常人直肠固有筋膜前、后、左、右侧的MRI显示率,以及所有研究对象的骶前筋膜、骶骨筋膜、腹膜返折、直肠侧韧带、下腹下丛的MRI显示率。结果 高分辨MRI可以清楚地显示直肠壁的黏膜层、黏膜下层和固有肌层,直肠癌术前T分期的总准确率为80%(16/20)。健康人直肠固有筋膜前、后、左、右侧的MRI显示率分别为71.7% (43/60)、96.7%(58/60)、90.0%(54/60)和83.3%(56/60)。Denonvillier′s筋膜、骶前筋膜、直肠骶骨筋膜、腹膜返折及下腹下丛的MRI显示率分别为68.8%(55/80)、65.0%(52/80)、87.8%(69/80)、86.3%(69/80)和90.0%(72/80);直肠侧韧带的显示率较低,左侧为53.8%(43/80),右侧为47.6%(38/80)。结论 高分辨MRI可以辨识直肠肠壁及其周围解剖细节,帮助直肠癌术前T分期及制定临床治疗方案,判断全直肠系膜切除手术的侧切缘是否浸润,提高微转移癌灶的手术切除率,减少手术并发症。  相似文献   

13.
多层螺旋CT对右肺下叶肺段、亚肺段动脉管径的测量   总被引:1,自引:1,他引:0  
目的利用多层螺旋CT测量活体右肺下叶肺段与亚肺段动脉管径的数值范围,为肺动脉病变的影像学诊断提供参考数据。方法选择274例无心肺疾病患者,行胸部CT增强扫描,按性别分男、女两组;按年龄(20~40岁、41~60岁、61岁以上)分3组,在最大密度投影(MIP)图像上测量右肺下叶肺段和亚段肺动脉管径的数值,并进行男、女两组及不同年龄组肺段与亚段肺动脉管径的比较分析。结果在MIP图像上能准确测量右肺各肺段及亚肺段肺动脉管径的数值,男、女性右肺下叶各肺段、亚肺段动脉管径比较,差异有显著性意义(P0.05);男、女各年龄组肺段与亚肺段动脉管径比较,差异有显著性意义(P0.05),尤其是20~40岁与61~85岁的年龄组之间。结论多层螺旋CT能清楚地显示右肺下叶肺段及亚肺段动脉是测量肺段和亚肺段动脉管径值的有效方法。  相似文献   

14.
缺血性脑卒中患者颈动脉血管壁磁共振检查的临床意义   总被引:1,自引:0,他引:1  
目的评价颈动脉血管壁磁共振检查在缺血性脑卒中的临床意义。方法 67例缺血性脑卒中患者,其中男性55例,女性12例,平均年龄64岁(46~81岁);31例同期住院的非缺血性脑卒中患者作对照,其中男性26例,女性5例,平均年龄65岁(44~80岁)。对两组患者行颈动脉血管壁磁共振检查,比较两组人群的颈动脉粥样硬化病变分型和管壁定量指标差异。结果缺血性脑卒中组颈动脉的最大血管总面积[(99.3±20.9)mm2]、最大管壁厚度[(4.1±1.3)mm]和最大管壁标准化指数(0.57±0.11)均明显高于对照组[(59.9±13.3)mm2、(2.9±1.1)mm、0.40±0.09](P均〈0.05)。缺血性脑卒中组的颈动脉复杂斑块(Ⅳ-Ⅴ型和Ⅵ型)的发生率高于对照组。结论颈动脉血管壁磁共振检查能有效筛查缺血性脑卒中患者的颈动脉粥样硬化病变,并为临床提供有价值信息。  相似文献   

15.
目的量化评估16层螺旋CT冠状动脉各分支图像质量,探讨冠状动脉CT成像的临床应用效果。方法采用16层螺旋CT对102例患者行回顾性心电门控冠状动脉成像,男60例,女42例,平均年龄(57.8±9.4)岁,平均心率(62.8±10.2)次/min。心率〈60次/min(n=40)为I组,60~70次/min(n=35)为Ⅱ组,〉70次/min(n=27)为Ⅲ组。4条冠状动脉分支(左主干、左前降支、左回旋支、右冠状动脉)分别用于图像质量分析。扫描原始数据以间隔10%在20%~80%时相分别回顾性重建冠状动脉图像,用横断面、曲面重建、容积再现等方法对冠状动脉显示率评估。用曲面重建方法测量冠状动脉各分支长度及近段和远段对比噪声比。结果①冠状动脉各分支平均显示长度:左主干(10.9±3.0)mm,左前降支(130.3±29.7)mm,左回旋支(82.8±19.8)mm,右冠状动脉(150.5±27.5)mm;②Ⅰ组60%和70%为最佳时相图像质量优,Ⅱ组60%时相为最佳时相图像质量优,Ⅲ组RCA较优的时相为40%,LM、LAD、LCX较优时相为60%。③所有冠状动脉分支平均对比噪声比10.9±3.2。结论16层螺旋CT有较好质量的冠状动脉图像,心率和时相影响冠状动脉的成像质量。  相似文献   

16.
目的:探讨肺血减少型先天性心脏病患者远端肺血管发育的评估手段及指标。方法:对47例肺血减少型先天性心脏病患者(A组)进行3DCE—MRA及超声心动和术中测量,将MRA测量结果与术前心动超声及术中测量值进行组内比较;选择其中15例(B组)和另外5例同年龄组原发病为非心源性且对心脏及肺血管发育无直接影响的开胸手术患者(C组)进行肺组织活检,形态半定量测量肺细小动脉平均中膜厚度百分比(MT%)和中膜面积百分比(MS%)、单位面积肺细小动脉数目(APSC)、单位面积平均肺泡数(MAN)、单位面积平均肺泡数/肺细小动脉数(AAR)。将B组与C组病理学检测数据进行比对研究。在B组中将MRA可显示的肺血管分枝级数与病理学检测数据进行相关性分析。结果:A组内比较,3DCE-MRA测量值与术中测量值及超声心动测得值之间差异统计学意义(P〉0.05);B组与C组比较,MT%和MS%差异没有统计学意义(P〉0.05),而APSC、MAN、AAR差异明显(P〈0.01);B组内肺动脉分枝级数与APSC、MAN呈正相关(P〈0.01),与AAR呈负相关(P〈0.01),与Mc Goon比值和PAI呈正相关(P〈0.05)。结论.3DCE—MRA对于肺血管发育的评估具有较高的实用性和准确性,基本可以替代有创的心导管检查,其所测量的Mc Goon比值和PAI指数和显示的肺动脉分枝级数对手术方式的选择,围术期并发症的预判有一定的指导意义。  相似文献   

17.
目的 观察骶椎的解剖形态及其与耻骨联合的位置关系,为骶椎正位X线摄影体位的优化设计提供解剖学依据。 方法 回顾性随机收集1000例患者骨盆腔CT影像,借助CT图像重组技术观测骶椎的解剖形态及其与耻骨联合的相对位置关系。 结果 骶椎均为前面凹陷、底朝上、尖向下后方走行,骶椎上下端中点连线M与人躯体长轴之间的夹角A均为锐角,耻骨联合位于骶椎的前正中偏下位置,其与骶椎下缘的连线N和躯体长轴垂线间夹角B>0 °(即耻骨联合上缘低于骶椎下缘的位置)占89.7%(897/1000);青少年组(14~45岁)角A为(35.86±6.88)°,明显低于中年组(46~69岁)(37.82±6.34)°和老年组(>69岁)(37.60±6.65)°(P<0.05),青少年组角B为(10.27±7.02)°,明显高于中年组(8.88±7.23)°和老年组(7.83±6.93)°(P<0.05),而中年组和老年组间差异均无统计学意义;男性角A(36.12±0.27)°和角B(6.27±0.25)°,均明显低于女性(38.03±0.33)°和(12.79±0.33)°(P<0.05)。 结论 CT图像重组技术可用于观察和分析骶椎的解剖形态及其与耻骨联合的位置关系,不同年龄段和不同性别者骶椎与耻骨联合的相对位置情况差异显著,可为骶椎正位X线摄影检查体位的优化设计提供可靠的解剖学依据。  相似文献   

18.
背景:平片及CT不能显示关节软骨的改变,磁共振虽可显示软骨,但常规序列软骨显像效果欠佳,因此若要提高MRI检出软骨病变的能力,序列的优化显得非常重要。 目的:比较骶髂关节常用磁共振成像序列,筛选适合骶髂关节软骨MRI最佳成像序列。 方法:对45健康志愿者分别行骶髂关节MRI自旋回波T1WI、T2WI、T1-flash-3d-water-cor、T2-me3d-cor和T2-me2d-cor和T1-se-cor-water-fil扫描,比较各个序列显示骶髂关节软骨的清晰度、内部信号变化及软骨表面缺损。 结果与结论:自旋回波T1WI和T2WI序列45均显示骶髂关节软骨为一条稍高信号带,关节间隙不清;梯度回波T1-se-cor-water-fil序列45均显示两侧关节面骨皮质与髂侧软骨、骶侧软骨及软骨间隙形成的5条平行线状结构;T2-me3d-cor、T1-flash-3D-water-cor-fil序列45例受检者关节软骨为一条明亮、清晰高信号,与周围骨皮质及骨髓分界非常清晰,但骶侧、髂侧软骨不能够区分。T2-me2d-cor序列 37例能显示髂侧、骶侧软骨及软骨间关节间隙,8例分辨不清;弥散成像序列仅部分层面能显示关节软骨,诸结构显示较模糊,信号强度对比不鲜明。结果说明,T1-se-cor-water-fil在关节软骨显示程度、内部信号变化和软骨表面缺损程度等方面明显优于其他序列。T1-flash-3d-water-cor、T2-me3d-cor和T2-me2d-cor对软骨表显示方面优于常规MRI序列,但不如T1-se-cor-water-fil。 中国组织工程研究杂志出版内容重点:组织构建;骨细胞;软骨细胞;细胞培养;成纤维细胞;血管内皮细胞;骨质疏松;组织工程   相似文献   

19.
目的 观测股前外侧皮瓣穿支及其源动脉CTA影像特点,为CTA在股前外侧穿支皮瓣“个性化”设计中的应用提供指导。 方法 收集28侧成人下肢CTA扫描数据,应用AW4.6工作站,重建三维图像,对旋股外侧动脉降支(DB)及其分支进行观测,统计数据包括穿支走行、数目、深筋膜穿出点位置,穿支源动脉走行、长度、内径。 结果 DB可分为共干型(Ⅰ型,64.2%)和单支型(Ⅱ型,35.8%)。28侧下肢总计发现穿支37支,其中3侧未发现明显穿支(10.7%)、15侧发现1支(53.6%)、9侧发现2支(32.1%)、1侧发现3支(3.6%);Ⅰ型、Ⅱ型DB平均每侧穿支数为(1.5±0.78)支、(1.0±0.66)支,肌间隙型穿支占比为37%、40%。Ⅰ型、Ⅱ型DB初级源动脉起始内径为(1.3±0.31)mm、(1.0±0.54)mm。 结论 CTA在观测股前外侧皮瓣穿支及及其源动脉解剖学参数方面具有较高应用价值,可以为股前外侧穿支皮瓣“个性化”设计提供指导。  相似文献   

20.
目的研究螺旋CT血管成像(CTA)和灌注成像(CTPI)对胃癌血供和血流动力学评价及意义。方法选取经病理检查确诊的胃癌患者88例,其中63例采用体部灌注扫描序列行灌注扫描,分析血容量(BV)、血流量(BF)、表面通透性(PS)、平均通过时间(MTT)与胃癌局部分化、侵袭的相关性。27例患者行动态增强扫描,分析胃癌的位置及供血血管。结果 27例增强扫描患者中20例肝固有动脉、腹腔干、胃网膜右动脉、胃左右动脉应用容积再现(VR)可清晰显示,最大密度投影(MIP)显示细小血管,胃癌血供与肿瘤生长位置有密切关系,胃癌血管基本来自胃自身血管,BV、BF、PS、MTT与T分期差异有统计学意义(P〈0.05);中高分化组与低分化组PS差异有统计学意义(P〈0.05),与BF、BV、PS、MTT无明显相关(P〉0.05)。结论螺旋CTA能够清晰显像胃部肿瘤的血管及血供,提供了肿瘤与血管关系的观察,CTPI可显示胃癌局部分化、侵袭程度。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号