首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
Indigo carmine (sodium indigotindisulfonate), a blue dye, has been widely used by surgeons to identify and to examine the urinary tract and is considered biologically inert and extremely safe. We present a case of severe life-threatening anaphylactoid reaction followed by cardiac arrest associated with intravenous indigo carmine injection.  相似文献   

3.
B Hammann 《Der Anaesthesist》1989,38(3):136-139
A case of diencephalic dysregulation is reported during urological endoscopy following the intravenous administration of indigo carmine. It should be kept in mind that according to the literature, indigo carmine has severe side-effects on the cardiovascular system caused by vasoconstriction. Ergotamine-like effects of indigo carmine due to direct vasoconstriction with spasm of the cerebral arteries are discussed.  相似文献   

4.
Chen M  Habib AS  Panni MK  Schultz JR 《Anesthesia and analgesia》2007,105(4):1130-1, table of contents
An extravasated IV catheter may have serious clinical consequences. These include the inability to circulate emergency medications, cause pain on injection, infection at the site, and tissue damage. Clinical signs such as swelling, redness, and pain with injection are valuable, but may not be helpful in the presence of obesity, edema, or in a tracheally intubated and sedated patient. Here we describe a case illustrating a novel approach in which we used an IV dye injection (indigo carmine) to detect a correctly placed and then an extravasated IV. The ability to see visible flow of IV dye intravascularly helped confirm the correct placement. The technique we describe is quick, safe, and inexpensive.  相似文献   

5.
6.
BACKGROUND: Cerebral oximetry is a noninvasive bedside technology using near-infrared light to monitor cerebral oxygen saturation (Sco2) in an uncertain mixture of arteries, capillaries, and veins. The present study used frequency domain near-infrared spectroscopy to determine the ratio of arterial and venous blood monitored by cerebral oximetry during normoxia, hypoxia, and hypocapnia. METHODS: Twenty anesthetized children aged < 8 yr with congenital heart disease of varying arterial oxygen saturation (Sao2) were studied during cardiac catheterization. Sco2, Sao2, and jugular bulb oxygen saturation (Sjo2) were measured by frequency domain near-infrared spectroscopy and blood oximetry at normocapnia room air, normocapnia 100% inspired O2, and hypocapnia room air. RESULTS: Among subject conditions, Sao2 ranged from 68% to 100%, Sjo2 from 27% to 96%, and Sco2 from 29% to 92%. Sco2 was significantly related to Sao2 (y = 0. 85 x -17, r = 0.47), Sjo2 (y = 0.77 x +13, r = 0.70), and the combination (Sco2 = 0.46 Sao2 + 0.56 Sjo2 - 17, R = 0.71). The arterial and venous contribution to cerebral oximetry was 16 +/- 21% and 84 +/- 21%, respectively (where Sco2 = alpha Sao2 + beta Sjo2 with alpha and beta being arterial and venous contributions). The contribution was similar among conditions but differed significantly among subjects (range, approximately 40:60 to approximately 0:100, arterial:venous). CONCLUSIONS: Cerebral oximetry monitors an arterial/venous ratio of 16:84, similar in normoxia, hypoxia, and hypocapnia. Because of biologic variation in cerebral arterial/venous ratios, use of a fixed ratio is not a good method to validate the technology.  相似文献   

7.
Near-infrared spectrophotometry assesses cerebral oxygen saturation (ScO(2)) based on the absorption spectra of oxygenated and deoxygenated hemoglobin and the translucency of biological tissue in the near-infrared band. In patients with icterus, however, bilirubin can potentially hinder cerebral oximetry. In 48 patients undergoing orthotopic liver transplantation, we related total plasma bilirubin to ScO(2) as determined from spectrophotometry with wavelengths of 733 and 809 nm. Before surgery, ScO(2) was 59% (15%-78%) (median with range) and bilirubin was 71 (6-619) micromol/L with a negative correlation (r = -0.72; P < 0.05). The 95% prediction interval included the lowest measurable ScO(2) of 15% at a bilirubin level of 370 micromol/L. During reperfusion of the grafted liver, the ScO(2) increased by 7% (-8% to 17%) (P < 0.05), and bilirubin did not influence this increase. In one patient, the ScO(2) remained below 15% despite a decrease in bilirubin from 619 to 125 micromol/L, suggesting that tissue pigmentation deposits also absorb light. In conclusion, bilirubin dampens the spectrophotometry-determined cerebral oxygen saturation at 733 and 809 nm. A bilirubin level of 370 micromol/L, tissue pigment deposits, or both, may render determination of cerebral oxygen saturation impossible. Even at high bilirubin values, changes in cerebral perfusion may be visible. IMPLICATIONS: In 48 patients undergoing liver transplantation, the interference of icterus on cerebral oximetry by near-infrared light was investigated. Bilirubin absorbed the near-infrared light and lowered the measured cerebral oxygen saturation. Even at high bilirubin values, changes in cerebral oxygenation, as seen during reperfusion of the grafted liver, may be visible.  相似文献   

8.
9.
BACKGROUND: Transluminal percutaneous carotid angioplasty and stenting (CAS) carries a risk of cerebral ischemia, hemorrhage, or edema due to relative hyperemia and hemodynamic instability during and after the procedure. Noninvasive monitoring of near-infrared regional cerebral oxygen saturation (SrO2) offers an indirect way to estimate cerebral blood flow. OBJECTIVE: To evaluate the behaviour of SrO2 during CAS and the usefulness of this variable for continuous monitoring of cerebral blood flow variation and neurological status. MATERIAL AND METHODS: Prospective study of 25 patients scheduled for unilateral CAS under monitored anesthesia care. SrO, and other hemodynamic and clinical data were recorded. A change in SrO2 (deltaSrO2) of 15% or more in comparison with the baseline value and lasting more than 30 seconds was considered clinically significant. Neurological complications in the first 24 hours were also registered. RESULTS: Baseline SrO, ranged from 51% to 75%. With administration of papaverine SrO2 values increased by a mean (SD) of 5.6% (6%) (P<.05 vs baseline). They decreased during angioplasty, -2.5% (5.7%) (P<.05 vs baseline), increased after 5 minutes, and fell again at 30 minutes to a level 3% (6.54%) above baseline. Two patients showed signs of elevated intracranial pressure after the procedures and also had ASrO2 readings exceeding 15%; measures to lower arterial hypertension reduced SrO2 in these patients. CONCLUSION: High interindividual variability of absolute SrO2 values has been confirmed. SrO, fluctuates with maneuvers that change cerebral blood flow in the same way. Changes can precede the onset of other clinical signs.  相似文献   

10.
11.
We studied the effect of sevoflurane and desflurane on regional cerebral oxygenation (rSO2). Twenty-two patients undergoing abdominal hysterectomy received sevoflurane and desflurane for 15 min each and 30 min apart under steady-state conditions in a randomized, crossover manner to maintain a bispectral index (BIS) of 40-50. In another 22 patients undergoing the same anesthesia and surgery BIS was maintained at 20-30. During the 15-min administration of each anesthetic at steady-state conditions rSO2, BIS, inspired and end-tidal anesthetic concentrations, end-tidal CO2, Spo2, systolic and diastolic blood pressures, and heart rate were recorded every 3 min. The rSO2 did not differ between sevoflurane and desflurane when BIS values were maintained between 40-50 or 20-30. The MAC(BIS) values required to maintain BIS at 40-50 and at 20-30 were 1.0 versus 1.2 (P = 0.004) and 1.6 versus 1.8 (P < 0.001) for desflurane and sevoflurane respectively. Higher rSO2 values were obtained by 1.6 MAC (71 +/- 13) than by 1 MAC of desflurane (66 +/- 10; P < 0.001) and by 1.8 MAC (72 +/- 11) than by 1.2 MAC of sevoflurane (66 +/- 13; P < 0.001). In conclusion, equipotent concentrations of desflurane or sevoflurane in terms of BIS are associated with similar rSO2 values, but larger anesthetic concentrations of both anesthetics increased the rSO2 values.  相似文献   

12.
13.
Two near-infrared spectroscopy (NIRS) devices were compared with regard to their responses to changes in cerebral hemoglobin oxygenation induced by hypoxia and hypercapnia in five healthy volunteers. Sensors belonging to each NIRS device were placed on opposite sides of the volunteer's forehead. The INVOS-3100A device, approved by the United States Food and Drug Administration, records the percentage of oxyhemoglobin (HbO2) saturation and the investigational NIRO500 device records absolute changes in HbO2, deoxyhemoglobin, and total hemoglobin in micromolar concentrations referenced to an arbitrary baseline. The volunteers breathed separate mixtures of 7% CO2 in O2 and 10% O2 for 5 minutes in random order. Arterial blood pressure, end-tidal CO2 (ETCO2), arterial O2 saturation, and electrocardiographic data were continuously monitored. Hypercapnia increased (p < 0.01) ETCO2 from 42+/-2 to 56+/-3 mm Hg (mean +/- standard deviation), resulting in a 7.3+/-0.2% increase (p < 0.005) in cerebral HbO2 saturation detected by the INVOS3100A device and an 11.6+/-3 microM increase (p < 0.0008) in HbO2 detected by the NIRO500. Hypoxia decreased (p < 0.01) arterial HbO2 saturation from 98+/-1 to 87+/-3%, causing a 5.1+/-1.2% decrease (p < 0.01) in the percentage of HbO2 saturation detected by the INVOS3100A device and a 9.7+/-6.3 microM decrease in HbO2 detected by the NIRO500. The responses of the NIRO500 and the INVOS3100A instruments to changes in cerebral oxygenation resulting from hypercapnia and hypoxia were generally similar; however, responses tended to be greater when recorded by the NIRO500 device, perhaps because, unlike the INVOS3100A device, the NIRO500 does not correct for skin and bone contamination.  相似文献   

14.
Near-infrared spectroscopy (NIRS) has been used to monitor regional cerebral oxygen saturation (rSO2) in patients at risk of cerebral desaturation during surgical and neurointerventional procedures. However, the quantitative capabilities of the method have been questioned, as has its validation compared with jugular bulb oximetry. Here, we compare NIRS data acquired during coil embolization procedures with incidence of vasospasm as detected from angiography. Thirty-two subarachnoid hemorrhage patients underwent embolization. Bilateral SomaSensor strips (Invos 4100, Somanetics) were affixed to the forehead at constant anatomic positions, avoiding frontal sinuses and scalp hair. Mean arterial pressure, SaO2, end-tidal pCO2, temperature and Hb were held within a narrow range during the procedure. Ipsilateral angiography was performed every 10 to 15 minutes. An independent neuroradiologist classified any vasospasm in the parent vessel as mild (25% baseline), moderate (50%), severe (75%), or total (100%). Of all, 15/32 (46.9%) patients developed spasm; in 2 it was severe or total. There was no significant association between World Federation of Neurological Surgeons grade and baseline rSO2 signal (either ipsilateral or contralateral to the side of the aneurysm) (P=0.598). There was no significant association between side of aneurysm and baseline rSO2 signal (P=0.243). However, episodes of angiographic spasm were strongly associated with reduction in trend ipsilateral NIRS signal (P<0.001); furthermore, the degree of spasm (especially more than 75% vessel diameter reduction) was associated with a greater reduction in same-side NIRS signal (P<0.001) (2-level random effects regression model, Stata 8.2, Stata Corp, TX). NIRS may have a useful role to play in the detection of cerebral desaturation secondary to vasospasm during neuroendovascular procedures.  相似文献   

15.
STUDY OBJECTIVE: To evaluate the relationship between continuous noninvasive monitoring of cerebral saturation (regional cerebral oxygen saturation [rSo2]) and occurrence of clinical and electroencephalographic (EEG) signs of cerebral ischemia during carotid cross-clamping. DESIGN: Prospective clinical study. SETTING: University hospital. PATIENTS: Fifty ASA physical status II and III inpatients undergoing elective carotid endarterectomy with a cervical plexus block. INTERVENTIONS: rSo2 was continuously monitored throughout surgery, while an independent neurologist evaluated the occurrence of both clinical and EEG signs of cerebral ischemia induced during carotid cross-clamping. MEASUREMENTS AND MAIN RESULTS: rSo2 was recorded 1 and 3 minutes after clamping the carotid artery during a 3-minute clamping test. In 5 patients (10%), the carotid clamping test was associated with the occurrence of clinical and EEG signs of cerebral ischemia. All these patients were treated with the placement of a Javid shunt, which completely resolved the symptoms. In no patient was permanent neurological injury reported at hospital discharge. In 4 of these patients, EEG signs of cerebral ischemia were present at both observation times, and in one of them, the duration of cerebral ischemia was less than 2 minutes. The percentage rSo2 reduction from baseline during the carotid clamping test was 17% +/- 4% in patients requiring shunt placement and only 8% +/- 6% in those who did not require it (P = .01). A decrease in rSo2 15% or greater during the carotid clamping test was associated with a 20-fold increase in the odd for developing severe cerebral ischemia (odds ratio, 20; 95% confidence interval, 6.7-59.2) (P = .001); however, this threshold had a 44% sensitivity and 82% specificity, with only 94% negative predictive value. CONCLUSIONS: Continuous rSo2 monitoring is a simple and noninvasive method that correlates with the development of clinical and EEG signs of cerebral ischemia during carotid cross-clamping; however, we could not identify an rSo2 threshold that can be used alone to predict the need for shunt placement because of the low sensitivity and specificity.  相似文献   

16.
17.
This report describes the acute hemodynamic effects of indigo carmine in a surgical patient with compromised cardiac function. A 68-year-old woman with stable but severe cardiac dysfunction and renal artery stenosis was scheduled for an elective aortorenal bypass procedure. No hemodynamic instability occurred during the operation until the patient was administered intravenous (IV) indigo carmine 5 ml. At that time, the patient experienced an acute increase in afterload, which resulted in acute left ventricular failure documented by a decrease in cardiac output (CO) and an increase in pulmonary artery pressure (PAP). Until further studies defining the mechanism for its hypertensive side effect are performed, indigo carmine should be used with caution in patients with severe cardiac dysfunction.  相似文献   

18.
The effect of nail polish on pulse oximetry   总被引:5,自引:0,他引:5  
A randomized, blind study examined the effect of nail polish color on measurement of oxygen saturation by pulse oximetry. Fourteen adult volunteers had blue, green, purple, black, and red nail polish applied to their finger nails. A strip-chart recording of oxygen saturation (Nellcor N100) was made in room air and later interpreted in a blinded fashion. The absorption spectra of the five polishes were determined by spectrophotometry. The spectra of nine other nail polishes and three intravenous dyes also were examined. Black, blue, and green nail polish significantly lowered oximeter readings of oxygen saturation. Blue and green produced greater decreases than purple and red; black produced an intermediate decrease. Some but not all nail polishes absorbed light at the wavelengths used by the pulse oximeter (660 nm and 940 nm). The degree of artifactual desaturation correlated best with the difference between absorbance at 660 nm and absorbance at 940 nm (r = 0.95). Spectrophotometric absorbance data suggest that other colors may interfere with pulse oximetry. On the basis of spectrophotometric data, brown-red nail polish was predicted to interfere with oximetry; subsequent pulse oximetry measurements confirmed the prediction. Nail polish should be removed routinely before pulse oximetry monitoring.  相似文献   

19.
Aron JH  Fink GW  Swartz MF  Ford B  Hauser MC  O'Leary CE  Puskas F 《Anesthesia and analgesia》2007,104(5):1034-6, tables of contents
Raynaud's phenomenon is characterized by episodes of arterial vasospasm precipitated by cold stress, usually affecting the digits of the hands. There is controversy about the occurrence of vasospasm in internal organ systems. In this report, we present a case of Raynaud's peripheral vasospasm accompanied by cerebral oxygen desaturation as detected by near infrared cerebral oximetry after separation from cardiopulmonary bypass.  相似文献   

20.
BACKGROUND: Near-infrared spectroscopy (NIRS) is a noninvasive optical monitor of regional cerebral oxygen saturation (rSO2). The aim of this study was to validate the use of NIRS by cerebral oximetry in estimating invasively measured mixed venous oxygen saturation (SvO2) in pediatric postoperative cardiac surgery patients. METHODS: Twenty patients were enrolled following cardiac surgery with intraoperative placement of a pulmonary artery (PA) or superior vena cava (SVC) catheter. Five patients underwent complete biventricular repair--complete atrioventricular canal (n=3) and other (n=2). Fifteen patients with functional single ventricle underwent palliative procedures--bidirectional Glenn (n=11) and Fontan (n=4). Cerebral rSO2 was monitored via NIRS (INVOS 5100) during cardiac surgery and 6 h postoperatively. SvO2 was measured from blood samples obtained via an indwelling PA or SVC catheter and simultaneously correlated with rSO2 by NIRS at five time periods: in the operating room after weaning from cardiopulmonary bypass, after sternal closure, and in the CICU at 2, 4, and 6 h after admission. RESULTS: Each patient had five measurements (total=100 comparisons). SvO2 obtained via an indwelling PA or SVC catheter for all patients correlated with rSO2 obtained via NIRS: Pearson's correlation coefficient of 0.67 (P<0.0001) and linear regression of r2=0.45 (P<0.0001). Separate linear regression of the complete biventricular repairs demonstrated an r=0.71, r2=0.50 (P<0.0001). Bland-Altman analysis showed a bias of +3.3% with a precision of 16.6% for rSO2 as a predictor of SvO2 for all patients. Cerebral rSO2 was a more accurate predictor of SvO2 in the biventricular repair patients (bias -0.3, precision 11.8%), compared with the bidirectional Glenn and Fontan patients. CONCLUSIONS: Regional cerebral oximetry via NIRS correlates with SvO2 obtained via invasive monitoring. However, the wide limits of agreement suggest that it may not be possible to predict absolute values of SvO2 for any given patient based solely on the noninvasive measurement of rSO2. Near-infrared spectroscopy, using the INVOS 5100 cerebral oximeter, could potentially be used to indicate trends in SVO2, but more studies needs to be performed under varying clinical conditions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏