1.
AIMS: The use of hemodialysis temporary dual-lumen catheters is often complicated by infections, which may be a significant cause of death among patients with end stage renal disease (ESRD). The aim of this study was to assess the incidence of bacteremia and bacterial colonization related to non-tunneled, non-cuffed, dual-lumen temporary catheters in patients with ESRD submitted to hemodialysis. METHODS: This study included 29 patients with ESRD. After catheter implantation, patients were monitored throughout the period of catheter permanence by means of blood samples collected weekly from a peripheral vein. Bacteria were isolated and identified according to CLSI recommendations. When catheters were removed for any reason, their tips were evaluated microbiologically. RESULTS: A total of 194 blood samples from the 29 patients implanted with 55 catheters were analyzed. Of these, 15.5% (30 samples) demonstrated bacterial growth, principally Staphylococcus epidermidis (64.5%). Twenty patients (68.9%) presented at least one positive blood culture during follow-up. The median time for catheter colonization was 18.5 days (95% CI: 16.8-30.3). Of the 55 catheters implanted, 28 (50.9%) showed bacterial colonization, corresponding to 23.4 episodes/1000 catheter/days and 9.2 episodes of bacteremia /1000 catheter/days. Fifteen of 28 catheter tips analyzed showed bacterial growth (53.5%). In 14 of these (93.3%), there was agreement between the isolates from the catheter tip and blood cultures. Of 24 episodes of positive blood cultures from 20 different patients in 17 episodes (70.8%), the patients showed no clinical signs or symptoms of bacteremia. CONCLUSIONS: The high incidence of catheter colonization, the correlation between blood and catheter tip cultures, and the occurrence of frequent cases of asymptomatic bacteremia justify the proposal of routine peripheral blood collections to monitor patients undergoing hemodialysis with temporary dual-lumen catheters.  相似文献   

2.
Polyurethane and Teflon subclavian vein catheters have been widely used for temporary vascular access for hemodialysis, but their use has been associated with a significant complication rate. A silicone dual-lumen catheter with a Dacron cuff placed in the internal jugular or subclavian vein was evaluated as a means of obtaining short-term vascular access. Sixty-two catheters in 54 patients provided a cumulative experience of 206 patient-months. Blood flow rates greater than or equal to 200 mL/min were achieved, with a mean recirculation of 2.1%. Catheter function was better with placement on the right side. Exit-site infections developed in nine patients, for a rate of 5.3 episodes per 100 patient-months; all resolved with antibiotics. Catheter-related bacteremia occurred in one patient, for a rate of 0.49 episodes per 100 patient-months, a rate much lower than rates reported for polyurethane and Teflon catheters. Clotting occurred in 24.5% of catheters, and thrombolytic therapy was always successful in restoring function. Because of the lower rate of complications, the silicone dual-lumen catheter with a Dacron cuff provides a safer alternative for short-term hemodialysis vascular access than the Teflon and polyurethane catheters.  相似文献   

3.
Bacteremia is often a serious and recurring problem in children with hemodialysis catheters. We report an outbreak ofEnterococcus bacteremia in a pediatirc hemodialysis unit occurring from June 1992 to June 1993. During this period, 18 episodes of bacteremia occurred in eight children: 11 infections were polymicrobial.Enterococcus fecalis was associated with 13 infections in five patients (8 polymicrobial). Other pathogens includedEnterobacter cloacae (5 infections),Staphylococcus (3),Staphylococcus epidermidis (2), andKlebsiella pneumoniae (2). AllEnterococcus infections occurred in patients with dual-lumen subclavian venous catheters. Skin and catheter sites were culture negative, except in one patient. Rectal swabs were positive forEnterococcus in five patients.Enterococcus was not isolated from any source within the unit. Serotypes of allEnterococcus isolates were different, except for 2 isolates in the same patient. Starting in June 1993, catheters were flushed after dialysis with vancomycin or ampicillin. Since initiating this procedure, further episodes ofEnterococcus bacteremia have not occurred. A questionnaire sent to other pediatric hemodialysis units failed to identifyEnterococcus among 26 cases of bacteremia. In conclusion: (1)Enterococcus is an unusual pathogen for hemodialysis-related bacteremia in children; (2) patients with dialysis catheters were predisposed to this infection; (3) a common source forEnterococcus could not be identified by either culture or by serotyping; (4) flushing catheters with antibiotics after dialysis was effective prevention.  相似文献   

4.
Tunneled catheters serve as interim access during maturation of a graft or fistula, or as a permanent vascular access in those patients who have exhausted their traditional access sites. However, bacteremia rates are high in patients with chronic catheters and indiscriminate removal of catheters during bacteremia increases morbidity and costs. A method to identify whether a catheter was colonized with the offending bacteria, without requiring catheter removal is desirable. We compared endoluminal brushing and heparin aspiration, to detect catheter colonization, in 24 asymptomatic patients undergoing elective tunneled hemodialysis catheter removal. The incidence of catheter colonization was highly correlated with catheter duration of inverted exclamation markY 30 days (p=0.03). Staphylococcus epidermidis represented 68% of the organisms isolated. No other organism accounted for more than 7% of the total. Fifteen (62.5%) of the 24 catheters had positive cultures. Eleven of the catheters were positive by culture of heparin aspirate and eight were positive by endoluminal brushing. Only four of the catheters were positive by both methods. The arterial lumen was more likely to have positive cultures than the venous lumen using either method. In this prospective investigation of tunneled hemodialysis catheters in asymptomatic patients we have demonstrated that a heparin aspirate sample is more likely to detect catheter colonization than a sample obtained using an endoluminal brush. Furthermore, 75% of catheters present for more than 30 days were colonized. Further study is needed to determine if the heparin aspirate method could be used in patients with bacteremia to accurately identify catheters that need removal.  相似文献   

5.
BACKGROUND: Central venous hemodialysis catheter-related infection is a major cause of morbidity and mortality in the hemodialysis (HD) population. Due to an impaired immune response, symptoms and signs of infection may not be obvious, and thus bacteremia is often diagnosed and treated protractedly. In contrast, induction of the acute phase response is frequently observed in HD patients even without infection. Moreover, positive catheter cultures may result from contamination, asymptomatic colonization or infection. The aim of the present study was to compare the number of colonies from HD catheter tips, with symptoms and signs of infection in HD patients. METHODS: In a 10-year, single-center study, 53 HD patients (29 men, 24 women; mean age 66 +/- 10 years) who had their dialysis catheters removed were divided into 3 groups according to the number of colonies growing after rolling the catheter tip across blood agar (group I: <15 colonies [n=22], II: 15-50 colonies [n=15], III: >50 colonies [n=16]). RESULTS: The maximum white blood cell (WBC) count did not differ significantly between patients with low- and high-density colonization (group I: 11.746 +/- 9.680 WBC/microL vs. group III: 13.479 +/- 6.252 WBC/microL, p=NS) while maximum C-reactive protein (CRP) levels were higher in patients with high-density colonization (group I: 8.6 +/- 6.8 vs. group III: 19.2 +/- 12.2 mg/dL, p<0.05). Density of bacterial colonization was associated with the maximum body temperature (group I: 37.6 degrees C +/- 1.1 degrees C vs. 38.7 degrees C +/- 0.9 degrees C, p<0.05). Moreover patients with high-density colonization showed increased bacteremia (group I: 33% vs. group III: 93%, p<0.01) as well as an increased mortality due to septicemia (group I: 9% vs. group III: 50%, p<0.01). Patients of group II exhibited intermediate values in all analyses. CONCLUSION: The semiquantitative culture technique can help to differentiate between contamination and infection of central venous HD catheters and provides important prognostic information in dialysis patients.  相似文献   

6.
Factors influencing function of temporary dialysis catheters   总被引:9,自引:0,他引:9  
AIM: To determine risk factors for failure of temporary dialysis catheters, we prospectively studied the outcome of 178 non-tunneled dual lumen catheters placed in 126 consecutive patients requiring treatment of acute renal failure (ARF) or end-stage renal disease (ESRD). METHODS: Internal jugular (IJ) or subclavian (SC) catheters were used in 122 instances and femoral catheters were employed in 56. RESULTS: IJ or SC catheters with tips in the right atrium or superior vena cava (n = 112) failed (defined as a blood flow < 250 ml/min) 17% of the time, compared with a 40% failure rate for catheters with more peripherally located tips (n = 10), p < 0.05, chi2 testing. In a multivariate analysis, use in ESRD and location peripheral to the SVC were risk factors for catheter failure. Use of one of three catheter brands was associated with a lower failure rate. Although mean venous pressures at 200 ml/min blood flow were higher in IJ or SC catheters that failed, the presence of a high venous pressure, number of catheter uses, IJ vs. SC placement, inpatient vs. outpatient status, and fresh venipuncture vs. placement over a guidewire passed through a previous catheter did not predict catheter malfunction. With femoral catheters, the only risk factor for failure was use in ESRD. CONCLUSION: Of the factors that can be influenced by placement technique, catheter tip location is most important. Whether one catheter brand is superior awaits further confirmation.  相似文献   

7.
Background The use of hemodialysis catheters is an essential component of dialysis practice. Children are particularly likely to require multiple courses of dialysis over their lifetime, hence the repeated need for vascular access. These catheters remain a significant source of morbidity and mortality. Methods All catheters inserted for hemodialysis at the Center of Pediatric Nephrology and Transplantation, Cairo University over a period of 40 months were studied. Patient data as well as data of catheter insertion, dwell, cause of removal and complications were reported. Results A total of 195 uncuffed central venous catheters were used for temporary access in 131 patients for a mean duration of 35.7 days. Of attempted insertions, 87.4% achieved successful access, of which 56% remained for the required period, 8.9% were accidentally dislodged, and 35.1% were removed due to complications—mostly infection. The overall rate of possible catheter-related bacteremia was 9.6 episodes/ 1,000 catheter days. Infection increased with longer catheter dwell. Nineteen cuffed tunneled catheters were surgically inserted and used for up to 11 months (mean 117 days). Loss of these catheters was attributed mainly to infection (ten episodes) and catheter thrombosis (six episodes). During the study, 317 femoral catheters were inserted. Conclusion Uncuffed central venous catheters are both needed and useful for short-term hemodialysis. Vascular access for extended durations may be provided by cuffed tunneled catheters. Infection is the major serious concern with both uncuffed and cuffed catheters.  相似文献   

8.
. Venous catheters have become an indispensable form of hemodialysis access. We evaluated catheter performance as temporary and long-term access in children with end-stage renal disease (ESRD). We assessed the survival rates and causes of catheter failure in 78 catheters used for hemodialysis access in 23 pediatric patients (aged 10 months to 22 years) with ESRD over a 5-year period. Median survival was 31 days for 56 uncuffed catheters. One- and 2-month actuarial survival was 69% and 48%, respectively. Reasons for removal were: elective (39%), kinking (36%), trauma (11%), infection (7%), and other (5%). Smaller catheters (7 or 9 French) were more likely to be removed for kinking (P = 0.003). One-year actuarial survival for 22 cuffed catheters was 27%. Cuffed catheters were removed due to: infection (36%), kinking (14%), elective (9%), trauma (9%) and other (9%). Twelve catheters were removed for infection. Infection rates leading to removal were 0.58 and 0.71 per patient-year for uncuffed and cuffed catheters, respectively. Staphylococcus species were cultured most commonly. We conclude that uncuffed catheters function well for short-term hemodialysis access of up to 2 months’ duration and cuffed catheters are successful for long-term access in children and adolescents with ESRD. Received April 1, 1996; received in revised form and accepted August 1, 1996  相似文献   

9.
Infection, mainly related to vascular access, is one of the main causes of morbidity and a preventable cause of death in hemodialysis patients. From January 1994 to April 1998 we conducted a prospective study to assess the incidence and risk factors of catheter-related bacteremia. One hundred and twenty-nine tunneled dual-lumen hemodialysis catheters were inserted percutaneously into the internal jugular vein in 89 patients. Bacteremia (n = 56) occurred at least once with 37 (29%) of the catheters (an incidence of 1.1/1,000 catheter-days); local infection (n = 45, 1/1,000 catheter-days) was associated with bacteremia in 18 cases. Death in 1 case was directly related to Staphylococcus aureus (SA) septic shock, and septicemia contributed to deaths in 2 additional cases. Catheters were removed in 48% of the bacteremic episodes. Treatment comprised intravenous double antimicrobial therapy for 15-20 days. Bacteriological data of bacteremia showed 55% involvement of SA. Nasal carriage of SA was observed in 35% of the patients with catheters. Bacteremic catheters were more frequently observed in patients with diabetes mellitus (p = 0.03), peripheral atherosclerosis (p = 0.001), a previous history of bacteremia (p = 0.05), nasal carriage of SA (p = 0.0001), longer catheter survival time (p = 0.001), higher total intravenous iron dose (p = 0.001), more frequent urokinase catheter infusion (p < 0.01), and local infection (p < 0.001) compared with non-bacteremic catheters. Monovariate survival analysis showed that significant initial risk factors for bacteremia were nasal carriage of SA (p = 0.00001), previous bacteremia (p = 0.0001), peripheral atherosclerosis (p = 0.005), and diabetes (p = 0.04). This study confirms the relatively high incidence of bacteremia with tunneled double-lumen silicone catheters and its potential complications. Possible preventive actions are discussed according to the risk factors.  相似文献   

10.
We evaluated our experience over a 4-year period with a silicone dual-lumen catheter with a Dacron cuff (SDLCDC) to determine if the catheter represents an alternative to the polytetrafluoroethylene graft for long-term vascular access for hemodialysis patients. Records of 131 patients who used 168 catheters were reviewed for catheter function, duration of use, and occurrence and response to treatment of complications. Eighty-five percent of catheters functioned adequately until their use was no longer required or the end of the study. One-year catheter survival estimate was 65% and median survival estimate was 18.5 months. Mean blood flow rate achieved was 243 mL/min and recirculation was 7.5%. Exit-site infection occurred in 21% of patients and bacteremia in 12%. There were significantly more exit-site infections in diabetics than nondiabetics (33% v 11%, P less than 0.02). Exit-site infections resolved with parenteral antibiotic therapy in 90% and bacteremia in 25% of cases without catheter removal. Unresolved bacteremia was the most common cause of catheter removal and led to the loss of 7% of catheters. Thrombotic complications occurred in 46% of catheters. Urokinase instillation successfully treated catheter occlusion in 81% of cases. When urokinase instillation failed, streptokinase infusion restored catheter patency 97% of the time. The literature on the polytetrafluoroethylene (PTFE) graft was reviewed, and the SDLCDC was found to be similar to the graft in function, duration of use, and frequency of infectious and thrombotic complications. We conclude that the catheter represents an alternative to the graft for long-term vascular access in hemodialysis patients. Because of the frequent complications with both accesses, neither should be considered optimal. Further research is required to improve vascular access for patients in whom placement of an arteriovenous fistula is not possible.  相似文献   

11.
Between January 1986 and December 1995, 18 episodes of bacteremia occurred in our pediatric patients undergoing chronic hemodialysis on an outpatient basis. Seven episodes were caused by coagulase-negative Staphylococcus, 6 by Staphylococcus aureus, 2 by Mycobacterium, and 1 each by Pseudomonas, Xanthomonas, and Enterococcus. In 6 cases, the catheter was retained with antimicrobial therapy alone, whereas 12 cases required removal of the catheter after some period of time. The subset of cases in which catheter removal was necessary included 2 cases of Mycobacterium fortuitum complex and 5 cases of Staphylococcus aureus. We found that Staphylococcus aureus bacteremia may be cleared with antibiotic therapy alone in a minority of cases (17%). In the 6 cases in which catheters were retained and infections cleared, the maximum length of time to sterilization of blood with appropriate antibiotics was 48 h. Received: 22 September 1998 / Revised: 28 June 1999 / Accepted: 30 June 1999  相似文献   

12.
永久性双腔血液透析导管流量及再循环率的测定   总被引:1,自引:0,他引:1  
目的了解不同型号永久性双腔血液透析留置导管的实际流量以及不同流量和连接方法下导管再循环率的情况,为永久性双腔导管的临床应用提供实证依据。方法将56例使用永久性双腔血液透析导管的血液透析患者根据留置导管不同分为Perm-cath组(P组)30例,Tal Palindrome TM组(T组)26例,利用Transonic HD02血液透析监护仪进行实际血流量监测。测定正接和反接状态下,泵设流量分别为150、200、250、300、350mL/min时的再循环率。结果无论正接还是反接,两组实际流量均能达到泵设流量的要求;不同泵设流量时正接和反接实际流量比较,差异无统计学意义(均P>0.05)。正接时泵设流量150~350mL/min,两组几乎没有再循环。反接时,不同泵设流量组内再循环率比较,差异无统计学意义(均P>0.05);但各不同泵设流量下,P组再循环率显著高于T组(均P<0.01)。结论两种永久性双腔血液透析留置导管血流量能满足泵设流量需求,正接时都没有再循环;反接时Tal Palindrome TM型再循环率比Permcath型低,两种导管再循环率不随泵设流量的增加而增加。因此,应尽量避免反接导管,必须反接时,可相应提高血流量,以保证透析效果。  相似文献   

13.
Tunneled central venous catheters are often used in children on chronic hemodialysis. This study was done to evaluate the spectrum of catheter-related bacteremia (CRB) and to determine predictors of recurrent CRB in children on hemodialysis. Chart review was performed in 59 children from a pediatric dialysis unit with chronic, tunneled, cuffed hemodialysis catheters between January 1999 and December 2003. CRB was diagnosed in 48 of 59 (81%) patients. The incidence of CRB was 4.8/1,000 catheter days. Overall catheter survival (290±216 days) was significantly longer than infection-free catheter survival (210±167 days, p<0.05). Organisms isolated were gram-positive in 67%, gram-negative in 14%, and polymicrobial in 19%. Systemic antibiotics cleared CRB in 34% and an additional 23% cleared with the inclusion of antibiotic-heparin locks; 43% required catheter exchange. There was a significant likelihood of early catheter exchange with polymicrobial CRB (p<0.01). Catheter loss occurred from infection in 63%. Risk factors for CRB included young age (<10 years) and presence of human immunodeficiency virus (HIV) infection. Patients with >2 initial positive blood cultures (p<0.0001) had a significantly higher rate of recurrence after 6 weeks of initial treatment. In conclusion, CRB remains a major determinant of catheter loss. However, overall catheter survival is longer than infection-free catheter survival, suggesting that systemic antibiotics with antibiotic-heparin locks should be the initial step in the management of CRB and this approach may salvage some catheters.  相似文献   

14.
Transvenous leads of cardiac rhythm devices (CRDs) are known to cause central stenosis and are vulnerable to contamination during hemodialysis access‐related bacteremia. In this retrospective study, nine consecutive chronic hemodialysis patients with transvenous CRD infection due to dialysis access‐related bacteremia and recurrent central stenosis are presented. Four patients with tunneled hemodialysis catheters (TDCs) and three with arteriovenous grafts experienced access‐related bacteremia that spread to the transvenous CRD. Two patients required repeated angioplasty procedures (less than 3 months apart) for central venous stenosis. Transvenous CRD was removed and replaced with an epicardial system in all. One patient with TDC switched to peritoneal dialysis and did not experience infection of the epicardial system despite two episodes of peritonitis. The remaining TDC (n = 3) and graft patients (n = 3) received a new TDC after the resolution of bacteremia. While all six experienced on average 1.5 episodes of catheter‐related bacteremia (average follow‐up = 14.5 months), none developed infection of the epicardial system. The patients with central stenosis have required only one angioplasty each for the past 8 and 6 months. To the best of our knowledge this is the first study to suggest that an epicardial approach might be a preferred method over transvenous leads for chronic hemodialysis patients.  相似文献   

15.
PURPOSE: To determine the feasibility and clinical outcomes of conversion of temporary to tunneled hemodialysis catheters using the same venous insertion site. METHODS: Data from 42 patients with existing temporary hemodialysis catheters referred for placement of tunneled hemodialysis catheters were retrospectively reviewed. In these patients, the temporary catheter was exchanged for a peel-away sheath, and a tunneled catheter was inserted using the existing venous access site. Technical success, procedural complications, and clinical outcomes were evaluated. Hemodialysis records were reviewed to assess catheter patency during a 30-day follow-up period. RESULTS: The study group consisted of 20 males and 22 females (mean age: 58 years). All 42 temporary catheters were successfully converted to tunneled hemodialysis catheters without immediate procedure-related complications. Follow-up data were available for 32 patients (total: 3038; median 71 catheter days). Nine catheters were removed for infection, yielding a catheter infection rate of 0.30/100 catheter days; three catheters were removed for blood flow <200 ml/min. 13 patients had catheters removed when catheters were no longer needed. Three patients died with working catheters. The patency rate was 72% at 30 days, with four catheters functioning at the end of the study period. CONCLUSION: Conversion of a temporary hemodialysis catheter to a tunneled hemodialysis catheter using the same venous insertion site is a safe procedure that avoids complications associated with venotomy and allows conservation of other central venous access sites. Patency and infection rates in these catheters are comparable to several studies of catheter exchange and de novo placement of tunneled hemodialysis catheters.  相似文献   

16.
A questionnaire, designed to determine the current habits of British nephrologists regarding temporary vascular access for hemodialysis, was sent to 62 renal units. Forty-six (74%) completed questionnaires were returned. Cannulation of the subclavian vein with a single-lumen catheter is the most popular technique. There is only limited use of double- or dual-lumen catheters in the United Kingdom. Previously unreported fatal complications of subclavian hemodialysis catheters are described.  相似文献   

17.
Subclavian hemodialysis catheter infections   总被引:1,自引:0,他引:1  
One hundred sixteen subclavian hemodialysis catheter placements in 88 patients were prospectively evaluated for catheter-related infections. Semiquantitative culture techniques and a rigid infection control protocol were used. The overall catheter colonization rate was 21.6% and catheter-associated bacteremia occurred in 9.4%. Catheters removed from febrile patients had much higher colonization (48.3%) and bacteremia (34.5%) rates. In a randomized study comparing infection rates in catheters tunneled subcutaneously or not tunneled, there was no significant difference in the incidence of infection. Catheters inserted over a guidewire to replace clotted or malfunctioning catheters were not associated with higher infection rates.  相似文献   

18.
Microbial blood infection represents a high risk for immuno-suppressed patients. Of all catheter-related infections in the bloodstream, 90% result from the use of central venous catheters, the main cause being microbial colonization at the catheter's insertion point or the catheter hub. Between January 2003 and December 2004, 102 patients received a renal transplant including 57 who received a triple-lumen central venous catheter (CVC) during the procedure. Two catheters were used: a standard polyurethane catheter placed in the jugular veina or the subclavian veina for group I, and polyurethane catheters with the AgION antimicrobial system always placed in the subclavian veina for group II. Care and maintenance of the CVCs was standardized in both groups. After catheter removal, the tips were analyzed microbiologically. Of 57 (43.9%) CVCs, 25 were found to be contaminated. In the first group 24 out of 41 CVCs (58.5%) showed bacterial growth, whereas in group II only one catheter (6.6%) had a biofilm. The most common contaminant (18 out of 25, 72%) was Staphylococcus epidermidis. In group II, two patients had positive blood cultures yet a microbiologically sterile CVC. None of the catheters with the AgION antimicrobial system had to be removed owing to local infection or intolerance. The continuous release of silver ions increases the protection against bacteria and fungi during the entire time of catheterization. Use of catheters with the AgION antimicrobial system lead to a marked reduction in catheter-associated infections of the bloodstream.  相似文献   

19.

Introduction

Infection is a major cause of morbidity and mortality in burns patients.

Methodology

A retrospective review of all 94 patients admitted to a regional burns ICU from 2004 to 2009 was performed. All the patients’ data and records of all culture isolates from a computerized hospital wide database were studied. Epidemiology of the patients, bacteriology information including yield and correlation of bacteremia with positive cultures from other sites were examined. In addition, the relationship between burns excision surgeries to bacteremia was analyzed.

Results

402 tissue cultures, 238 wound swab cultures, 269 endotracheal cultures, 125 urine cultures, 236 tip of monitoring line cultures and 474 blood cultures were studied. Acinetobacter baumannii was the most prevalent bacteria for all culture methods. Within 24 h of bacteremia, the tissue, line tips, endotracheal and wound swab cultures had yielded very similar pathogens (>70% of the time) to those from the blood stream. Furthermore 60% of all bacteremic episodes occur within 48 h of the surgery.

Conclusion

In ICUs where multidrug resistant pathogens are endemic, the choice of appropriate antimicrobial empiric cover should be guided by the intensity of colonization with these organisms as indicated by the cultures from various sites.  相似文献   

20.
Almost 30% of prevalent hemodialysis patients use catheters for vascular access although outcomes are superior with the use of either an arteriovenous fistula or a synthetic graft. Catheter complications are a major cause of morbidity and mortality for hemodialysis patients and increase the burden on the health care system. Surface‐treated catheters have been developed to combat the three most common causes of catheter failure: infection, fibrin sheath formation, and thrombus formation. Two types of catheter surface treatments are available: antimicrobial coatings and antithrombotic coatings. Surface treatment of central venous catheters with antimicrobial materials reduces both bacterial colonization and the incidence of catheter‐related bacteremia in critical care patients by 30–50%. Antithrombotic coatings reduce platelet adhesion, inhibit the inflammatory response, and reduce thrombus formation on coronary stents, ventricular assist devices, central venous catheters, and vascular grafts. However, few reports on the use of surface‐treated catheters in the chronic hemodialysis patient population exist. At the present time, it is difficult to justify the increased cost of surface‐treated catheters for chronic hemodialysis in the absence of clinical data demonstrating that they reduce catheter‐related complications in this patient population.  相似文献   