首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 25 毫秒
1.
Endoleak is the most common complication after endovascular aneurysm repair. The most common type of endoleak, a type II endoleak, typically follows a benign course and is only treated when associated with increasing aneurysm size. In this case report, we describe a ruptured abdominal aortic aneurysm due to a late, type II endoleak occurring 10 years after endovascular aneurysm repair that was successfully treated by transarterial embolization.  相似文献   

2.
Endovascular repair of isolated iliac artery aneurysms is an established safe and effective management option. Type II endoleak is a potential complication, but rarely results in significant morbidity or mortality. We report a case of a patient who presented with a ruptured internal iliac artery aneurysm secondary to a Type II endoleak. To our knowledge this and the following method of managing this have not been previously reported. Established methods of managing endoleaks, such as intravascular transfemoral embolisation and open or laparoscopic ligation, were not possible. Therefore, we resorted to a novel approach to this type of aneurysm and successfully performed a transcutaneous direct puncture and embolisation of the superior gluteal artery.  相似文献   

3.
A patient with a ruptured iliac aneurysm was admitted to the Emergency Department in hypovolemic shock. He had previously undergone surgical treatment for an infrarenal abdominal aortic aneurysm, which was managed with a terminal-terminal Dacron tube graft. Subsequently, he developed two iliac aneurysms, which were treated endovascularly with two wall-grafts in the right and one wall-graft in the left iliac arteries. He suffered chronic renal failure and arterial hypertension. Contrast-enhanced computed tomography showed rupture of the right iliac aneurysm and dislocation of the two wall-grafts. He was treated in an emergency situation with the implantation of an iliac endograft that bridged the two wall-grafts, which resulted in hemostasis and stabilization of his condition. Five days later, in an elective surgical situation, he was treated with the implantation of an aorto-uni-iliac endograft combined with a femoral-femoral bypass. He was discharged 5 days later in good condition. At the 4 year follow-up visit, the endoprosthesis remained in place with no evidence of an endoleak. In conclusion, overlapping of endografts should be avoided, if possible. Strict surveillance of the endovascularly treated patient remains mandatory.  相似文献   

4.
An 81-year-old woman with ruptured mycotic thoracic aortic aneurysm was treated with endovascular placement of stent-grafts fabricated from expanded polytetrafluoroethylene and Z-stents. Although exclusion of the aneurysm was achieved at the end of the procedure, a type I endoleak developed on the following day. Despite emergent surgical resection of the aneurysm and extra-anatomical reconstruction, the patient died 2 days later. Stent-graft repair may not be a suitable method for the treatment of ruptured mycotic aneurysm in the presence of active infection.  相似文献   

5.
This report presents 3 procedures with visceral “chimney stenting” in conjunction with an endovascular aneurysm sealing (EVAS) device, known as chEVAS, for treatment of type 1a endoleak. It includes the first published chEVAS in a patient with previous fenestrated endovascular aneurysm repair (FEVAR). Cases include an 80-year-old man 8 years after FEVAR for a juxtarenal abdominal aortic aneurysm (AAA); an 85-year-old woman 9 months after endovascular aneurysm repair (EVAR) for a ruptured infrarenal AAA; and an 84-year-old woman 3 months after EVAR for a symptomatic infrarenal AAA. Technical success was achieved in all cases, with 1 postoperative death. The remaining 2 patients had no residual type 1a endoleak at 10 and 14 months respectively.  相似文献   

6.
We report the case of a patient who underwent endovascular repair and then reintervention as a result of the presence of a persistent endoleak complicated by an aortocaval fistula. A 76-year-old patient with a history of endovascular treatment for abdominal aortic aneurysm 2 years earlier had a palpable abdominal mass, high-output cardiac failure, and renal failure. A computed tomographic scan and angiography revealed bending of the right iliac limb, a type I endoleak, and rupture of the aneurysm into the inferior vena cava with aortocaval fistula formation. An iliac extension was positioned in the right external iliac artery. The procedure was finished successfully. Control angiography showed normal flow within the endoprosthesis, and both iliac arteries were without signs of endoleakage and aortocaval fistula. Ectatic common iliac artery may lead to a late distal attachment site endoleak. The application of a stent graft in cases of secondary aortocaval fistula after stent graft repair is a good option, particularly in emergency cases.  相似文献   

7.
The optimal treatment for type II endoleaks remains unclear. The present report describes a case of ischemic skin ulceration after glue embolization of a type II endoleak with challenging access in a multiply comorbid 82-year-old woman with an expanding aneurysm sac 3 years after endovascular aneurysm repair. Embolization was performed from a proximal position with an n-butyl cyanoacrylate/Ethiodol mixture to allow flow into the endoleak because direct sac puncture was hazardous. One week after intervention, an eschar, which progressed to superficial necrosis as a result of partial nontarget delivery of sclerosant, developed over the left iliac crest. The eschar was self-limiting, with complete resolution by 6 months.  相似文献   

8.
We report the case of a patient who developed an asymptomatic pseudoaneurysm in the left external iliac artery after transplant nephrectomy. The pseudoaneurysm most probably arose as a suture aneurysm from the external iliac artery after removal of the graft renal artery. Obviously we can not exclude the possibility it was a true aneurysm, although this seems much less likely. The pseudoaneurysm was detected during a routine CT scan and was treated interventionally with a stent-graft. One month later the asymptomatic patient underwent a vascular ultrasound examination including color Doppler, power Doppler, and B-flow as a routine control. An endoleak with collapse of the stent-graft was diagnosed. There was no evidence of stent infection. At a reintervention, the pseudoaneurysm was successfully treated using two uncovered Palmaz stents at the proximal and distal edge of the stent graft. Peri- and post-interventional ultrasound and CT angiography confirmed the exclusion of the aneurysm without an endoleak.  相似文献   

9.
PURPOSE: To evaluate the utility of time-resolved MR angiography (TR-MRA), compared with digital subtraction angiography (DSA), in the classification of endoleaks in patients who have undergone endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: Thirty-one patients who had undergone EVAR to repair an abdominal aortic aneurysm were evaluated with both TR-MRA and DSA to determine endoleak etiology. The patient population consisted of 26 men and 5 women with a mean age of 78.5 years (range, 55-93 years). The mean time interval between TR-MRA and DSA was 1.5 weeks (range, 1-8 weeks). Endoleaks were classified as type II when enhancement of the external iliac vessels was observed before the appearance of the endoleak; otherwise the endoleak was classified as type I or III. The results of TR-MRA classification were compared with the reference gold standard, DSA. RESULTS: Agreement between TR-MRA and DSA regarding endoleak classification occurred in 30 of 31 cases (97%). Discordant classification occurred in a case in which a Type II endoleak was misclassified as a Type III due to failure to visualize a lumbar vessel. CONCLUSION: TR-MRA is highly effective in classifying endoleaks following EVAR when compared with DSA.  相似文献   

10.
The authors report a case of a delayed type IIIb endoleak with sac expansion 6 years after an endovascular repair of an abdominal aortic aneurysm with an Ancure bifurcated stent-graft. The presumed etiology of the leak was secondary to erosion of the main body graft material by metal stents placed within the graft to correct kinking of the iliac limbs at the index operation. The endoleak was successfully treated by endovascular means with an aortouni-iliac device, contralateral iliac plug followed by a femoral-to-femoral bypass graft.  相似文献   

11.
The purpose of the note is to describe a new technique for type II endoleak treatment, using an alternative approach through femoral venous access. Three patients who developed type II endoleak after endovascular repair of abdominal aortic aneurysm were treated with direct transcaval puncture and embolization inside the aneurysm sac. The detailed technique is described. All patients were treated without any complications and discharged 48 hours after the treatment. At 1 month follow-up the computed tomograph scan did not show a recurrence of a type II endoleak. The management of patients with type II endoleak is a controversial issue and different techniques have been proposed. We suggest an alternative technique for type II endoleak treatment. The feasibility and the advantages of this approach can offer new possibilities for the diagnosis as well as for the treatment of this complication.  相似文献   

12.
PURPOSE: Evaluation of 6-year results of abdominal aortic aneurysm (AAA) treatment by Ella stent-grafts with regard to safety and effectivity in relation to morphology of the aneurysm. METHODS: From a group of 172 patients with AAA, in whom elective endovascular treatment was considered, 120 of them (69.8%) were found to be suitable for this type of therapy. The bifurcated type of stent-graft was implanted in 97 patients, uniiliacal type in 19 patients and only four patients were found to be suitable for tubular type of stent-graft. Additional necessary procedures (internal iliac artery occlusion or contralateral common iliac artery occlusion in a group of patients with uniiliacal type of stent-graft) were performed surgically during the stent-graft implantation. CT and US controls were performed at 3, 6 and 12 months after implantation, later every 12 months. RESULTS: Primary technical success was achieved in 109 of the 120 patients (91%). Primary endoleak was recorded in 11 patients (primary endoleak type Ia in seven patients, type Ib in three patients and type IIIa in one patient). Assisted technical success after reintervention or spontaneous seal was 98.3%. Surgical conversion was indicated in two patients (1.7%). Perioperative mortality rate was 3.3%. Total average follow-up period was 20.7 months (range from 2 to 60 months). In nine patients (7.5%) secondary endoleak type II was found at control CT or US, in three patients partial thrombosis of the stent-graft was found. There was no aneurysm rupture during follow-up. CONCLUSION: Treatment of AAA with Ella stent-graft system is effective and safe. Bifurcated stent-graft is the most frequently used type. Uniiliacal type of stent-graft is used by us only in cases of complicated morphology.  相似文献   

13.
This report describes the case of a ruptured mycotic aneurysm of the left common iliac artery, successfully treated with endovascular stent-grafting. A 64-year-old woman underwent diagnostic coronary angiography complicated by an infected hematoma of the left groin. Seven days later, she developed methicillin-resistant Staphylococcus aureus septicemia and CT scan evidence of perivascular inflammation around the left common iliac artery. This was followed by rupture of a mycotic aneurysm of the left common iliac artery. The lesion was successfully treated with a stent-graft and prolonged antibiotic therapy, and the patient remains free of infection 10 months later. Accumulating evidence suggests that endovascular repair can be used safely for the repair of ruptured infected aneurysms.  相似文献   

14.
The purpose of this study was to assess the feasibility and effectiveness of percutaneous endovascular repair of ruptured abdominal aortic aneurysms (AAAs) previously treated by EVAR. In the last year, two male patients with AAAs, treated 8 and 23 months ago with bifurcated stent-graft, were observed because of lumbar pain and hemorragic shock. Multidetector computed tomography (MDCT) showed a retroperitoneal hematoma; in both cases a type III endoleak was detected, in one case associated with a type II endoleak from the iliolumbar artery. The procedures were performed in the theater, in emergency. Type II endoleak was treated with transcatheter superselective glue injection; type III endoleaks were excluded by a stent-graft extension. The procedures were successful in both patients, with immediate hemodynamic stabilization. MDCT after the procedure showed complete exclusion of the aneurysms. In conclusion, endovascular treatment is a safe and feasible option for the treatment of ruptured AAAs previously treated by EVAR; this approach allows avoidance of surgical conversion, which is technical very challenging, with a high morbidity and mortality rate.  相似文献   

15.
Aortocaval fistula (ACF) is a rare complication of abdominal aortic aneurysm (AAA). We report the endovascular repair of an AAA rupture into the inferior vena cava. A 78-year-old woman was admitted to our hospital for acute hypotension. She presented with a pulsatile abdominal mass and became rapidly anuric. Abdominal computed tomography (CT) showed an AAA rupture into the inferior vena cava. The features of the AAA made it suitable for endovascular repair. To prevent pulmonary embolism caused by the presence of sac thrombosis near the vena cava lumen, a temporary vena cava filter was deployed before the procedure. A bifurcated stent-graft was placed with the patient under local anaesthesia, and the AAA was successfully treated. A transient type II endoleak was detected on CT 3 days after endograft placement. At routine follow-up 6 and 12 months after the procedure, the patient was in good clinical condition, and the type II endoleak had sealed completely. Endovascular treatment offers an attractive therapeutic alternative to open repair in case of ACF; however, only small numbers of patients have been treated, and long-term follow-up interval is lacking.  相似文献   

16.
PURPOSE: To develop canine aneurysm models that can reproduce type II endoleaks after endovascular aneurysm repair (EVAR) with stent-grafts. MATERIALS AND METHODS: A fusiform infrarenal abdominal aortic aneurysm model (AAA) was surgically created with a jugular vein patch, while preserving collateral vessels (n = 3). To allow comparative studies within the same animal, a bilateral iliac aneurysm model was also constructed with venous patches and surgical re-implantation of the sacroiliac trunk (n = 3). Stent-grafts were implanted by femoral approach at least 2 months later in both aortic and iliac models. Follow-up imaging was performed by Doppler ultrasound (US) and angiography until animals were killed 3 months after EVAR. RESULTS: Angiography revealed immediate type II leaks in all cases. Leaks were still present at autopsy 3 months after EVAR in all cases, and were revealed at pre-death angiography in all but one case. At autopsy, leaks were characterized by the presence of large endothelialized channels that formed within the thrombus between the stent-graft and the aneurysmal wall. CONCLUSION: As shown in this pilot study, persistent type II leaks after EVAR can be reproduced in aortic and iliac animal models. The iliac model can be created bilaterally in the same animal, thus allowing for comparative evaluation of different therapies. These models could be used to better understand the mechanisms of endoleak, and to assess future developments aimed to improve the outcomes after EVAR.  相似文献   

17.
We present a unique case of abdominal aortic aneurysm initially presenting with inferior vena cava compression leading to deep venous thrombosis, for which the patient subsequently underwent an endovascular aortic repair. Aorto-uni-iliac endografting was performed for subacute occlusion of left common iliac artery complicated by proximal type 1 endoleak. Subsequent management of the endoleak was successful, using a liquid embolic agent (cyanoacrylate) by transarterial approach. Transarterial catheter embolization with glue and coils is a feasible technique for high flow type 1 endoleaks. Glue injection carries the risk of non-target embolization, and thus this option should be reserved for experienced hands.  相似文献   

18.
The aim of the study was to describe the successful endovascular management of a patient who was admitted urgently with a second episode of acute abdominal aortic aneurysm (AAA) 30 months after emergency endovascular abdominal aortic aneurysm repair (eEVAR) for a ruptured AAA. The patient, an 84 year-old male physician, presented with severe acute abdominal and back pain. Contrast-enhanced computer tomography scanning showed type III endoleak owing to complete disconnection of both graft limbs and the prosthetic main body. Treatment consisted of acute stent-grafting with two bridging stent-grafts to seal the endoleak and reline the graft. The patient is alive and well 6 months postoperatively. This case indicates the need for follow-up after eEVAR, but also that complications can be managed endovascularly.  相似文献   

19.
Hybrid stent-graft procedures with visceral revascularization have been reported as an alternative treatment option for thoracoabdominal aortic aneurysms (TAAAs), although the potential advantages of reduced morbidity and mortality compared with open surgical repair have not been definitively demonstrated. Endovascular aneurysm repair is associated with endoleaks in as many as 20% of cases in some series, often requiring repeat intervention. In the present case, during follow-up after a hybrid TAAA repair, a patient developed a type II endoleak originating from a celiac artery that was not ligated at its origin. The endoleak was successfully treated by transcatheter coil embolization.  相似文献   

20.
PurposeTo review the effect of preoperative embolization of the inferior mesenteric artery (IMA) before endovascular aneurysm repair (EVAR) on subsequent endoleaks and aneurysm growth.Materials and MethodsBetween August 2002 and May 2010, 108 patients underwent IMA embolization before EVAR. Coil embolization was performed in all patients in whom the IMA was successfully visualized and accessed during preoperative conventional angiography. In this cohort, the incidences of type II endoleak, aneurysm sac volume enlargement at 24 months, and repeat intervention were compared with a group of 158 consecutive patients with a patent IMA on preoperative computed tomography angiography but not on conventional angiography, who therefore did not undergo preoperative embolization.ResultsThe incidence of type II endoleak was significantly higher in patients not treated with embolization (49.4% [78 of 158] vs 34.3% [37 of 108]; P = .015). The incidence of secondary intervention for type II endoleak embolization was also significantly higher in those who did not undergo embolization (7.6% [12 of 158] vs 0.9% [one of 108]; P = .013). At 24 months, an increase in aneurysm sac volume was observed in 47% of patients in the nonembolized cohort (21 of 45), compared with 26% of patients in the embolized cohort (13 of 51; P = .03). No aneurysm ruptures or aneurysm-related deaths were observed in either group. One patient in the embolization group developed mesenteric ischemia and ultimately died.ConclusionsPreoperative embolization of the IMA was associated with reduced incidences of type II endoleak, aneurysm sac volume enlargement at 24 months, and secondary intervention.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号