首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
In 1995, new certification requirements for all nonpowered, air-purifying particulate filter respirators were put in place when 42 CFR 84 replaced 30 CFR 11. However, the certification requirements for all other classes of respirators, including powered air-purifying respirators (PAPRs), were transferred to 42 CFR 84 from 30 CFR 11 without major changes. Since the inception of 42 CFR 84, researchers have learned that the efficiency of electrostatic filter media, in contrast with mechanical filter media, can be rapidly degraded by oil aerosols. Further, confusion may exist among respirator users, since electrostatic PAPR filters have the same magenta color assigned to high-efficiency filters for nonpowered particulate respirators that have been tested and certified for use against oil aerosols (i.e., P100 filters). Users may expect that the magenta color of certified PAPR filters indicates suitability for use against oil aerosols. This may not be the case. To illustrate the potential degradation of electrostatic PAPR filters, new filters certified under 42 CFR 84 were tested using a TSI model 8122 Automated Respirator Tester against charged and neutralized DOP aerosols with intermittent loading schedules. The performance of a magenta-colored electrostatic PAPR filter--one for which the manufacturer's user instructions appropriately indicates is not suitable for use in oily environments--was compared with the performance of several mechanical PAPR filters. In tests against both DOP aerosols, the electrostatic PAPR filter showed a significant decrease in performance at DOP loadings exceeding 400 mg, whereas mechanical filters showed no significant change in the performance except at extremely high loadings. The decreased performance of the electrostatic PAPR filter was found to be significantly greater when tested against a neutralized DOP aerosol when compared with a charged DOP aerosol. While laboratory tests show that the filtration efficiency of this electrostatic PAPR filter degrades with exposure to DOP aerosol, the observed laboratory degradation may or may not affect workplace performance, as similar degradation has not been verified in workplace studies. Based on these laboratory results, a proposed method for evaluating high-efficiency PAPR filters is presented. This proposed method would ensure that high-efficiency PAPR filters (> or = 99.97% efficient and magenta in color) meet critical performance criteria when loaded.  相似文献   

2.
A study was conducted at a secondary lead smelter to evaluate the workplace performance of the 3M W-344 and Racal AH3 powered air-purifying respirators equipped with helmets and high efficiency filters. The research protocol developed for the study has been described in a companion paper. The results of the study indicate that the mean lead concentrations, measured inside the facepiece of both PAPRs, were significantly less than the OSHA lead exposure limit of 50 micrograms/m3. The means of the workplace protection factor measurements on both PAPRs were significantly less than the PAPR selection guide protection factor classification of 1000. Correlation analysis of preshift quantitative fit factors and corresponding workplace protection factors indicated no linear association between these two measures of performance. This finding suggests that for PAPRs equipped with helmets and high efficiency filters quantitative fit factors as presently determined are not indicative of the workplace protection which the respirators provide. Since the PAPR protection factor classification of 1000 was originally based on quantitative fit factors, the lack of a demonstrated association between quantitative fit factors and workplace protection as found in this study may explain why their performance was significantly less than expected.  相似文献   

3.
Twelve subjects wore an N95 filtering facepiece respirator (N95 FFR), one tight-fitting full facepiece powered air-purifying respirator (PAPR), two loose-fitting PAPRs, and one elastomeric/PAPR hybrid for 1 hr each during treadmill walking at 5.6 km/hr while undergoing physiological and subjective response monitoring. No significant interaction (p ≥ .05) was noted between the five respirators in heart rate, respiratory rate, oxygen saturation, transcutaneous carbon dioxide, and perceptions of breathing effort or discomfort, exertion, facial heat, and overall body heat. Respirator deadspace heat/humidity were significantly greater for the N95 FFR, whereas tympanic forehead skin temperatures were significantly greater for the hybrid PAPR. Temperature of the facial skin covered by the respirator was equivalent for the N95 FFR and hybrid PAPR, and both were significantly higher than for the other three PAPRs. Perception of eye dryness was significantly greater for a tight-fitting full facepiece PAPR than the N95 FFR and hybrid PAPR. At a low-moderate work rate over 1 hr, effects on cardiopulmonary variables, breathing perceptions, and facial and overall body heat perceptions did not differ significantly between the four PAPRs and a N95 FFR, but the tight-fitting, full facepiece PAPR increased perceptions of eye dryness. The two loose-fitting PAPRs and the full facepiece tight-fitting PAPR ameliorated exercise-induced increases in facial temperature, but this did not translate to improved perception of facial heat and overall body heat.  相似文献   

4.
A study was conducted at a secondary smelter to evaluate the workplace performance of the 3M Model W-344 and Racal Model AH3 powered air-purifying respirators ( PAPR ) equipped with helmets and high efficiency filters. The research protocol developed for obtaining leakage measurements in the field provides for proper respirator fitting, use, wear, maintenance and worker supervision, all of which are problems commonly associated with data acquisition when field testing respirators. The protocol proved to be very workable, even though it required extensive worker and equipment monitoring. Based upon the successful implementation of this protocol, the performance of these PAPRs should be indicative of their best performance under the workplace conditions experienced in this study. This research protocol is proposed as a model for conducting field studies on other types of respirators as well as the basis on which to develop new and improved field test procedures. The results of one such study are presented in a comparison paper.  相似文献   

5.
Leakage from loose-fitting PAPRs (powered air-purifying respirators) can compromise the safety of wearers. The Martindale Centurion MAX multifunction PAPR is a loose-fitting PAPR that also incorporates head, eye, and ear protection. This respirator is used in mines where coal dust usually is controlled by ventilation systems. Should the respirator be depended on for significant respiratory protection? Ten human volunteers were asked to wear the Centurion MAX inside a fog-filled chamber. Their inhalation flow rates were measured with small pitot-tube flowmeters held inside their mouths. They were video imaged while they breathed deeply, and the points at which the fog reached their mouths were determined. Results showed that an average of 1.1 L could be inhaled before contaminated air reached the mouth. As long as the blower purges contamination from inside the face piece during exhalation, the 1.1 L acts as a buffer against contaminants leaked due to overbreathing of blower flow rate.  相似文献   

6.
The effects of intermittently loading small masses of sodium chloride aerosol on the filtration efficiency of N-95 filtering facepiece respirators was investigated. The National Institute for Occupational Safety and Health (NIOSH) certifies that N-95 respirators must provide at least 95 percent filtration efficiency against a sodium chloride aerosol challenge as per the respirator certification (42 CFR 84) test criteria. N-95 respirators are specified for protection against solid and water-based particulates (i.e., non-oil aerosols). New N-95 respirators from three different manufacturers were loaded with 5 +/- 1 mg of sodium chloride aerosol one day a week, over a period of weeks. Aerosol loading and penetration measurements were performed using the TSI 8130 Filter Tester. Respirators were stored uncovered on an office desktop outside the laboratory. To investigate environmental and temporal effects of filters being stored without sodium chloride exposure, control respirators were stored on the desk for various lengths of time before being initiated into weekly testing. For all manufacturers' respirators, the controls showed similar initial penetrations on their day of initiation (day zero) to those of the study samples on day zero. As the controls were tested weekly, they showed similar degradation rates to those of the study samples. Results show that some of the manufacturers' models had penetrations of greater than 5 percent when intermittently exposed to sodium chloride aerosol. It is concluded that intermittent, low-level sodium chloride aerosol loading of N-95 respirators has a degrading effect on filter efficiency. This reduction in filter efficiency was not accompanied by a significant increase in breathing resistance that would signal the user that the filter needs to be replaced. Furthermore, it was noted that the effect of room storage time prior to initial exposure was much less significant.  相似文献   

7.
New electrostatic filter media has been developed for use in 42 CFR 84 negative pressure particulate respirator filters. This respirator filter media was not available for evaluation prior to the change from 30 CFR 11 to 42 CFR 84. Thus, characterization of this filter media is warranted. In this study, the new 42 CFR 84 electrostatic respirator filters were investigated with respect to filter penetration and most penetrating particle size. Three different models of N95 filters, along with one model each of the N99, R95, and P100 class filters were used in this study. First, three of each filter were loaded with a sodium chloride (NaCl) aerosol, and three of each filter were loaded with a dioctyl phthalate (DOP) aerosol to obtain normal background penetration results for each filter. Then, two new filters of each type were dipped in isopropanol for 15 seconds and allowed to dry. This isopropanol dip should reduce or eliminate any electrostatic charge on the fibers of each filter, as reported in the technical literature. These dipped filters, along with controls of each filter type, were tested on a TSI 8160 filter tester to determine the most penetrating particle size. These same filters were then tested against a NaCl aerosol to get final penetration values. Electret filters rely heavily on their electrostatic charge to provide adequate filter efficiencies, and correlations between penetration and a filter's electrostatic characteristics are found in the technical literature. In all six of the filter models tested, filter penetration values increased considerably and the most penetrating particle size noticeably shifted toward larger particles. These results are important in better understanding how these new filter materials perform under various conditions, and they indicate the need for additional research to define environmental conditions that may affect electrostatic filter efficiency.  相似文献   

8.
The fit-test method for powered air-purifying respirators described here allowed quantitative determination of the leakage of PAPRs that offered PFs ranging from 50 to greater than 10,000. Five types of PAPRs were tested on 10 subjects selected from a test panel representing a wide range of facial sizes. PAPRs tested provided all subjects with PFs of 1000 or greater when operated with the blowers on, while PFs observed with the blower off, for two tight-fitting facepieces, ranged between 50 and 100. The exercises used in these test procedures are believed to be typical of movements made by persons wearing respiratory protective equipment and performing light work. Studies of PFs obtained by workers wearing respiratory protective equipment in industry would be necessary to establish how well the developed laboratory test methods predict the level of protection offered to workers wearing the equipment.  相似文献   

9.
Several respirator performance criteria are set to satisfy the physiological requirements of the worker. In particular, Ve and PFI must be understood and used appropriately in the design process. Filtration principles and the nature of workplace aerosols must also be understood to determine appropriate test conditions for particulate respirator filters. Current filter test criteria assure that significant aerosol penetration will not occur in the workplace. It is unlikely that existing positive-pressure respirators can assure positive pressure in the breathing zone at all times for all wearers. High, unsustainable work rates and activities such as running in place have been shown to cause negative-pressure excursions under laboratory and workplace conditions. Because these excursions are brief and infrequent for today's respirators, both logic and performance measurements indicate they have a negligible effect on exposure. Filters could no doubt be designed to pass extreme test criteria. Similarly, it may be possible to design positive-pressure respirators to maintain positive pressure 100 percent of the time for all users. However, it is likely that cost and size would increase and comfort could decrease. Further, available evidence demonstrates that today's respirators provide their expected level of protection when properly selected, used, and maintained. As such, there is no demonstrated need for radical design changes.  相似文献   

10.
This study aimed to evaluate the efficacy of powered air-purifying respirators (PAPRs) worn by the workers, and to investigate the effect of this application on exposure and preclinical effects in terms of workplace measuring and biomarker monitoring in ITO sputter target manufacturing plants and workers, respectively. Fifty-four workers were recruited and investigated from 2010–2012, during which PAPRs were provided to on-site workers in September 2011. Each worker completed questionnaires and provided blood and urine samples for analysis of biomarkers of indium exposure and preclinical effects. Area and personal indium air samples were randomly collected from selected worksites and from participants. The penetration percentage of the respirator (concentration inside respirator divided by concentration outside respirator) was 6.6%. Some biomarkers, such as S-In, SOD, GPx, GST, MDA, and TMOM, reflected the decrease in exposure and showed lower levels, after implementation of PAPRs. This study is the first to investigate the efficacy of PAPRs for reducing indium exposure. The measurement results clearly showed that the implementation of PAPRs reduces levels of indium-related biomarkers. These findings have practical applications for minimizing occupational exposure to indium and for managing the health of workers exposed to indium.  相似文献   

11.
Respirators are used to help reduce exposure to a variety of contaminants in workplaces. Test aerosols used for certification of particulate respirators (PRs) include sodium chloride (NaCl), dioctyl phthalate, and paraffin oil. These aerosols are generally assumed to be worst case surrogates for aerosols found in the workplace. No data have been published to date on the performance of PRs with welding fumes, a hazardous aerosol that exists in real workplace settings. The aim of this study was to compare the performance of respirators and filters against a NaCl aerosol and a welding fume aerosol and determine whether or not a correlation between the two could be made. Fifteen commercial PRs and filters (seven filtering facepiece, two replaceable single-type filters, and six replaceable dual-type filters) were chosen for investigation. Four of the filtering facepiece respirators, one of the single-type filters, and all of the dual-type filters contained carbon to help reduce exposure to ozone and other vapors generated during the welding process. For the NaCl test, a modified National Institute for Occupational Safety and Health protocol was adopted for use with the TSI Model 8130 automated filter tester. For the welding fume test, welding fumes from mild steel flux-cored arcs were generated and measured with a SIBATA filter tester (AP-634A, Japan) and a manometer in the upstream and downstream sections of the test chamber. Size distributions of the two aerosols were measured using a scanning mobility particle sizer. Penetration and pressure drop were measured over a period of aerosol loading onto the respirator or filter. Photos and scanning electron microscope images of clean and exposed respirators were taken. The count median diameter (CMD) and mass median diameter (MMD) for the NaCl aerosol were smaller than the welding fumes (CMD: 74 versus 216 nm; MMD: 198 versus 528 nm, respectively). Initial penetration and peak penetration were higher with the NaCl aerosol. However, pressure drop increased much more rapidly in the welding fume test than the NaCl aerosol test. The data and images clearly show differences in performance trends between respirator models. Therefore, general correlations between NaCl and weld fume data could not be made. These findings suggest that respirators certified with a surrogate test aerosol such as NaCl are appropriate for filtering welding fume (based on penetration). However, some respirators may have a more rapid increase in pressure drop from the welding fume accumulating on the filter. Therefore, welders will need to choose which models are easier to breathe through for the duration of their use and replace respirators or filters according to the user instructions and local regulations.  相似文献   

12.
Tuberculosis (TB) can be transmitted to susceptible healthcare workers via inhalation of droplet nuclei carrying viable Mycobacterium tuberculosis bacilli. Several types of respiratory protective devices are compared with respect to efficacy against droplet nuclei penetration: surgical masks, disposable dust/mist particulate respirators (PRs), elastomeric halfmask respirators with high-efficiency (HEPA) filters, and powered airpurifying respirators (PAPRs) with elastomeric halfmask facepieces and HEPA filters. It is estimated that these devices permit, respectively, 42%, 5.7%, 2%, and 0.39% penetration of droplet nuclei into the facepiece. More limited data for the disposable HEPA filtering-facepiece respirator suggest that it would allow droplet nuclei penetration of 3% or less, similar to the value estimated for the elastomeric halfmask HEPA filter respirator. Because a respirator wearer's cumulative infection risk depends on the extent of droplet nuclei penetration, the cumulative risk will differ, given use of these different respirators. Hypothetical but realistic “low-exposure” and “high-exposure” scenarios are posed that involve, respectively, a 1.6% and a 6.4% annual risk of infection for healthcare workers. For the low-exposure scenario, the 10-year cumulative risks given no respirators versus surgical masks versus disposable dust/mist PRs versus elastomeric halfmask HEPA filter respirators versus HEPA filter PAPRs are, respectively, 15%, 6.7%, 0.94%, 0.33%, and .064%. For the high-exposure scenario, the 10-year cumulative risks for no respirator use versus use of the same four types of respirators are, respectively, 48%, 24%, 3.7%, 1.3%, and 0.26%. The use of disposable HEPA filtering-facepiece respirator should permit cumulative risks close to those estimated for the elastomeric halfmask HEPA filter respirator. It is concluded that when an infectious TB patient undergoes a procedure that generates respiratory aerosols, and when droplet nuclei source control is inadequate, healthcare workers attending the patient may need to wear highly protective respirators, such as HEPA filter PAPRs.  相似文献   

13.
Performance capability of respirators has traditionally been evaluated by testing components of the respirator (e.g., filter efficiency), facepiece fit, total inward leakage, or some other measure of performance evaluated under laboratory conditions. In recent years, increased emphasis has been placed on development of test methods suitable for evaluating respirator performance in the workplace. The goal of such testing is to evaluate the level of protection provided by respirators in the work environment. The AIHA Respiratory Protection Committee believes that workplace testing of respirators has the potential to be an excellent tool for increasing knowledge about the effectiveness of respiratory protection. However, a number of technical issues remain to be addressed before optimal test protocols and data analysis methods can be defined. The progress made to date in workplace testing will be reviewed, and broader discussion about key elements that must be considered when developing guidelines for testing respirators in the workplace will be initiated.  相似文献   

14.
National Institute for Occupational Safety and Health recommends the use of particulate respirators for protection against nanoparticles (<100 nm size). Protection afforded by a filtering facepiece particulate respirator is a function of the filter efficiency and the leakage through the face-to-facepiece seal. The combination of particle penetration through filter media and particle leakage through face seal and any component interfaces is considered as total inward leakage (TIL). Although the mechanisms and extent of nanoparticle penetration through filter media have been well documented, information concerning nanoparticle leakage through face seal is lacking. A previous study in our laboratory measured filter penetration and TIL for specific size particles. The results showed higher filter penetration and TIL for 50 nm size particles, i.e. the most penetrating particle size (MPPS) than for 8 and 400 nm size particles. To better understand the significance of particle penetration through filter media and through face seal leakage, this study was expanded to measure filter penetration at sealed condition and TIL with artificially introduced leaks for 20-800 nm particles at 8-40 l minute volumes for four N95 models of filtering facepiece respirators (FFRs) using a breathing manikin. Results showed that the MPPS was ~45 nm for all four respirator models. Filter penetration for 45 nm size particles was significantly (P < 0.05) higher than the values for 400 nm size particles. A consistent increase in filter penetrations for 45 and 400 nm size particles was obtained with increasing breathing minute volumes. Artificial leakage of test aerosols (mode size ~75 nm) through increasing size holes near the sealing area of FFRs showed higher TIL values for 45 nm size particles at different minute volumes, indicating that the induced leakage allows the test aerosols, regardless of particle size, inside the FFR, while filter penetration determines the TIL for different size particles. TIL values obtained for 45 nm size particles were significantly (P < 0.05) higher than the values obtained for 400 nm size particles for all four models. Models with relatively small filter penetration values showed lower TIL values than the models with higher filter penetrations at smaller leak sizes indicating the dependence of TIL values on filter penetration. When the electrostatic charge was removed, the FFRs showed a shift in the MPPS to ~150 nm with the same test aerosols (mode size ~75 nm) at different hole sizes and breathing minute volumes, confirming the interaction between filter penetration and face seal leakage processes. The shift in the MPPS from 45 to 150 nm for the charge removed filters indicates that mechanical filters may perform better against nanoparticles than electrostatic filters rated for the same filter efficiency. The results suggest that among the different size particles that enter inside the N95 respirators, relatively high concentration of the MPPS particles in the breathing zone of respirators can be expected in workplaces with high concentration of nanoparticles. Overall, the data obtained in the study suggest that good fitting respirators with lower filter penetration values would provide better protection against nanoparticles.  相似文献   

15.
Intelligible speech communication while wearing air-purifying respirators is critical for law enforcement officers, particularly when they are communicating with each other or the public. The National Institute for Occupational Safety and Health (NIOSH) requires a 70% overall performance rating to pass speech intelligibility certification for commercial chemical, biological, radiological, and nuclear air-purifying respirators. However, the speech intelligibility of certified respirators is not reported and the impact on operational performance is unknown. The objective of this effort was to assess the speech intelligibility of 12 certified air-purifying respirators and to predict their impact on operational performance. The NIOSH respirator certification standard testing procedures were followed. Regression equations were fit to data from studies that examined the impact of degraded speech intelligibility on operational performance of simple and complex missions. The impact of the tested respirators on operational performance was estimated from these equations. Performance ratings observed for each respirator were: MSA Millennium (90%), 3M FR-M40 (88%), MSA Ultra Elite (87%), Scott M110 (86%), North 5400 (85%), Scott M120 (85%), Avon C50 (84%), Avon FM12 (84%), Survivair Optifit (81%), Drager CDR 4500 (81%), Peltor-AOSafety M-TAC (79%), and 3M FR-7800B (78%). The Millennium and FR-M40 had statistically significantly higher scores than the FR-7800B. The Millennium also scored significantly higher than the M-TAC. All of the tested respirators were predicted to have little impact on simple and complex mission performance times and on simple mission success rate. However, the regression equations showed that 75% of missions that require complex communications would be completed while wearing the Millennium, FR-M40, or Ultra Elite but that only 60% would be completed successfully while wearing the FR-7800B. These results suggest that some certified respirators may have a greater impact on speech communications than others.  相似文献   

16.
Air-purifying respirators must be certified following the National Institute for Occupational Safety and Health (NIOSH) filter test criteria (30 CFR 11). The criteria specify a range for the mean particle size and the measure of spread permissible for the test aerosol. The authors' experiments have shown that aerosol penetration as a function of particle size differs considerably among certified respirators of the same type. Filtering facepieces (disposable respirators) and cartridges of the dust-mist, dust-mist-fume, and high-efficiency particulate air type were tested. The respirators were sealed to mannequins in a test chamber. The aerosol concentrations inside and outside the respirator were measured by an aerodynamic particle sizer and a laser aerosol spectrometer over a particle size range of 0.1 to 15 microns. Five flow rates ranging from 5 to 100 L/min were used to study flow dependency. The aerosol penetration through the filters is presented as a function of particle size. Aerosol penetration and pressure drop are combined to express the performance of each filter in terms of "quality factor." Under the same test conditions, the quality factor of one respirator may be as much as 6.6 times more than that of another respirator of the same type. The filter quality factor has a greater aerosol size dependency as airflow and aerosol size increase. In general, cartridges have a larger surface area than filtering facepieces but not necessarily lower filter penetration or higher filter quality.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

17.
To evaluate filter efficiency and performance of environmental enclosures for tractors, 3- to 4-year-old tractor enclosure combinations (cabs retrofitted to tractors after manufacturing) were studied at a custom pesticide applicators facility. Optical particle counters were used to measure the aerosol number concentration inside and outside the cab. The ratio of these concentrations multiplied by 100 is termed percentage penetration, the amount of the aerosol that penetrates into the enclosure. For particles in the 0.3 to 0.4 microm range, penetration into the cab was reduced from 11 to 0.4% in the following sequential steps. First, manufacturing mistakes were corrected by fixing a bowed flange and inappropriate sealing of the sheet metal used to separate incoming air from air that had passed through the filter. This reduced aerosol penetration from 11 to 4.8%. Replacing gasket material on the used filter reduced penetration from 4.8 to 0.65%. This suggests that the filter gaskets are deforming and allowing leakage. Also, the filter media were evaluated for aerosol penetration as a function of particle size and were tested per the criteria stipulated in 42 CFR 84 for negative pressure air-purifying particulate respirators. These results showed penetration through the filter media of less than 0.03%, indicating that filter media were not a major source of aerosol leakage into the cab. The results suggest that the manufacturer should implement a quality control program to ensure that minimal aerosol penetration criteria into the cabs are met and an acceptable maintenance program exists to ensure compliance. Furthermore, the degradation of filter gasket material over time needs to be minimized to ensure that the environmental cabs continue to provide acceptable performance.  相似文献   

18.
National Institute for Occupational Safety and Health (NIOSH) certification test methods employ charge neutralized NaCl or dioctyl phthalate (DOP) aerosols to measure filter penetration levels of air-purifying particulate respirators photometrically using a TSI 8130 automated filter tester at 85 L/min. A previous study in our laboratory found that widely different filter penetration levels were measured for nanoparticles depending on whether a particle number (count)-based detector or a photometric detector was used. The purpose of this study was to better understand the influence of key test parameters, including filter media type, challenge aerosol size range, and detector system. Initial penetration levels for 17 models of NIOSH-approved N-, R-, and P-series filtering facepiece respirators were measured using the TSI 8130 photometric method and compared with the particle number-based penetration (obtained using two ultrafine condensation particle counters) for the same challenge aerosols generated by the TSI 8130. In general, the penetration obtained by the photometric method was less than the penetration obtained with the number-based method. Filter penetration was also measured for ambient room aerosols. Penetration measured by the TSI 8130 photometric method was lower than the number-based ambient aerosol penetration values. Number-based monodisperse NaCl aerosol penetration measurements showed that the most penetrating particle size was in the 50 nm range for all respirator models tested, with the exception of one model at ~200 nm size. Respirator models containing electrostatic filter media also showed lower penetration values with the TSI 8130 photometric method than the number-based penetration obtained for the most penetrating monodisperse particles. Results suggest that to provide a more challenging respirator filter test method than what is currently used for respirators containing electrostatic media, the test method should utilize a sufficient number of particles <100 nm and a count (particle number)-based detector.  相似文献   

19.
This investigation aims to explore determinants of exposure to particle size-specific welding fume. Area sampling of ultrafine particles (UFP) was performed at 33 worksites in parallel with the collection of respirable particles. Personal sampling of respirable and inhalable particles was carried out in the breathing zone of 241 welders. Median mass concentrations were 2.48 mg m(-3) for inhalable and 1.29 mg m(-3) for respirable particles when excluding 26 users of powered air-purifying respirators (PAPRs). Mass concentrations were highest when flux-cored arc welding (FCAW) with gas was applied (median of inhalable particles: 11.6 mg m(-3)). Measurements of particles were frequently below the limit of detection (LOD), especially inside PAPRs or during tungsten inert gas welding (TIG). However, TIG generated a high number of small particles, including UFP. We imputed measurements 相似文献   

20.
Fiber aerosols are known to have different aerodynamic behaviors than spherical particles and usually carry higher electrostatic charges. We investigated the effects of flow rate and charge status of filter cartridges on the penetration of spherical and fiber aerosols. Four types of test respirator filters were selected: two for passive respirators, one for a powered respirator, and one disposable respirator. Surface charges on respirator filters were determined using a noncontact field electrostatic field meter. Penetration tests were performed for filter cartridges before and after charge neutralization. The surface charge measurements on the respirator filters showed that some filters, including those used in disposable face masks, are charged to enhance the collection efficiency. Only high-efficiency particulate air filters performed consistently for both spherical test aerosols and the three types of asbestos fibers. The surface charge potential of filter cartridges and flow rate did not appear to affect the performance of these filters. In contrast to the high-efficiency filters, the aerosol penetration performance of low-efficiency filters and face masks deteriorated when the charge potential on the filter was removed. Our data also showed that the surface charges decreased in a high-temperature, high-humidity environment and disappeared after 1 week. Deposition of spherical particles and fibers in the charged disposable facemask filter was enhanced. For charged-neutralized, low-efficiency filter cartridges, asbestos fibers may penetrate more than spherical particles with a mean particle size of 0.3 microm diameter.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号