首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Objective

To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions.

Materials and Methods

We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups.

Results

A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n = 24), the imaging-histologic discordance (n = 5), and the imaging findings showing disease progression (n = 20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (p = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies.

Conclusion

The outcomes of the sonographically guided core biopsies performed with the 11-gauge vacuum-assisted device were better than those outcomes of the biopsies performed with the 14-gauge automated gun in terms of underestimation, rebiopsy and the false negative rate, although these differences were not statistically significant.  相似文献   

2.
A decision model was used to compare the relative costs of the 14-gauge automated gun technique to the 14-gauge and 11-gauge vacuum-assisted techniques for stereotactic biopsy of noncalcified breast lesions. Probability and cost variables were estimated from clinical experience with 76 automated gun biopsies, seventy-eight 14-gauge vacuum-assisted biopsies and thirty-nine 11-gauge vacuum-assisted biopsies. The 14-gauge automated gun was the preferred strategy from a cost standpoint: the 14-gauge vacuum technique was 1.19 times more expensive, and the 11-gauge was 1.22 times more expensive.  相似文献   

3.
OBJECTIVE: The purpose of this study was to compare the diagnostic accuracy of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy techniques in the diagnosis of ductal carcinoma in situ of the breast. MATERIALS AND METHODS: We retrospectively reviewed 41 consecutive lesions that had been diagnosed as ductal carcinoma in situ using stereotactic needle biopsy. The first 21 lesions had been biopsied using a 14-gauge automated gun; the remaining 20 lesions, using an 11-gauge vacuum-assisted device. Surgical histopathologic results at lumpectomy were compared with the findings at needle biopsy and defined as either concordant, when only ductal carcinoma in situ (i.e., no evidence of invasive carcinoma) was evident at surgery, or discordant, when invasive carcinoma was found. One patient from the automated gun group was lost to follow-up and was not included in the analysis. RESULTS: Invasive carcinoma was found at surgery in seven (35%) of the 20 cases diagnosed using the automated gun compared with three (15%) of the 20 cases diagnosed using the vacuum-assisted device (p = .13). In all three of these discordant vacuum-assisted cases, only microinvasive disease was found at surgery. However, in only two of the seven discordant automated gun cases was only microinvasive disease found at surgery. CONCLUSION: The 11-gauge directional vacuum-assisted biopsy technique may improve the accuracy of ductal carcinoma in situ diagnosis. Underestimation of disease still occurs, however.  相似文献   

4.
OBJECTIVE: The purpose of this study was to compare the outcome of sonographically guided core biopsies performed with the 14-gauge automated gun with the outcome of those performed with the 11-gauge vacuum-assisted device. Outcome was defined in terms of missed tumors, the need (both immediate and delayed) for a second biopsy, histologic underestimation, and complication rates. MATERIALS AND METHODS: We retrospectively reviewed all sonographically guided core biopsies performed between January 1997 and August 2001. Before February 2000, biopsies were performed using the 14-gauge automated gun and after that time, with either the 14-gauge automated gun or the 11-gauge vacuum-assisted device. During the study period, 181 biopsies were performed with the 14-gauge automated gun and 100 with the 11-gauge vacuum-assisted device. RESULTS: The histologic results of the core biopsies were similar for the group who underwent biopsy with the 14-gauge automated gun and the group who underwent biopsy with the 11-gauge vacuum-assisted device: malignant, 19% versus 19%; benign, 78% versus 79%; and high-risk lesion or other, 3% versus 2%, respectively (p > 0.7). Complications were rare and similar for both methods: 2% for the 14-gauge automated gun and 3% for the 11-gauge vacuum-assisted device (p = 0.46). A second biopsy was recommended immediately after the first in 14% of the patients who underwent biopsy with the 14-gauge automated gun versus 17% of those who underwent biopsy with the 11-gauge vacuum-assisted device (p = 0.47). Recommendation for delayed rebiopsy due to interval change occurred in 2.5% of the patients who underwent biopsy with the 14-gauge automated gun method and 3% of those who underwent biopsy with the 11-gauge vacuum-assisted device (p = 0.94). CONCLUSION: No significant differences were found in the outcomes of sonographically guided core biopsies performed with the automated gun compared with those performed with the vacuum-assisted device in terms of missed cancers, underestimation, complications, or the need (immediate or delayed) for a second biopsy.  相似文献   

5.
OBJECTIVE: This investigation compares the frequency of histologic underestimation of breast carcinoma that occurs when a large-core needle biopsy reveals atypical ductal hyperplasia or ductal carcinoma in situ with the automated 14-gauge needle, the 14-gauge directional vacuum-assisted biopsy device, and the 11-gauge directional vacuum-assisted biopsy device. SUBJECTS AND METHODS: Evaluation of 428 large-core needle biopsies yielding atypical ductal hyperplasia (139 lesions) or ductal carcinoma in situ (289 lesions) was performed. The results of subsequent surgical excision were retrospectively compared with the needle biopsy results. RESULTS: For lesions initially diagnosed as ductal carcinoma in situ, underestimation of invasive ductal carcinoma was significantly less frequent using the 11-gauge directional vacuum-assisted biopsy device when compared with the automated 14-gauge needle (10% versus 21%, p < 0.05) but was not significantly less frequent when compared with the 14-gauge directional vacuum-assisted device (10% versus 17%, p > 0.1). For lesions diagnosed initially as atypical ductal hyperplasia, underestimation of ductal carcinoma in situ and invasive ductal carcinoma was significantly less frequent using the 11-gauge directional vacuum-assisted biopsy device compared with the 14-gauge directional vacuum-assisted device (19% versus 39%, p = 0. 025) and with the automated 14-gauge needle (19% versus 44%, p = 0. 01). CONCLUSION: The frequency of histologic underestimation of breast carcinoma in lesions initially diagnosed as atypical ductal hyperplasia or ductal carcinoma in situ using large-core needle biopsy is substantially lower with the 11-gauge directional vacuum-assisted device than with the automated 14-gauge needle and with the 14-gauge directional vacuum-assisted device.  相似文献   

6.
OBJECTIVE: The purpose of this study was to compare the usefulness of, and cost of diagnosing with, different breast biopsy methods for women with calcifications highly suggestive of malignancy. MATERIALS AND METHODS: One hundred thirty-nine women with calcifications highly suggestive of malignancy underwent diagnostic biopsy. Of these, 89 women had stereotactic biopsy with a 14-gauge automated needle (n = 25), 14-gauge vacuum-assisted probe (n = 17), or 11-gauge vacuum-assisted probe (n = 47); and 50 women had diagnostic surgical biopsy. Medical records were reviewed. Cost savings for stereotactic biopsy were calculated using Medicare data. RESULTS: The median number of operations was one for women who had stereotactic biopsy versus two for women who had diagnostic surgical biopsy. The likelihood of undergoing a single operation was significantly greater for women who had stereotactic rather than surgical biopsy, among all women (61/89 [68.5%] vs. 19/50 [38.0%], p < 0.001) and among women treated for breast cancer (55/77 [71.4%] vs. 6/37 [16.2%], p = 0.0000001). Stereotactic 11-gauge vacuum-assisted biopsy, as compared with 14-gauge automated core or 14-gauge vacuum-assisted biopsy, was significantly more likely to spare a surgical procedure (36/47 [76.6%] vs. 16/42 [38.1%], p = 0.0005). Stereotactic 11-gauge vacuum-assisted biopsy resulted in the greatest cost reduction, yielding savings of $315 per case compared with diagnostic surgical biopsy; for women with solitary lesions, stereotactic 11-gauge biopsy decreased the cost of diagnosis by 22.2% ($334/$1502). CONCLUSION: For women with calcifications highly suggestive of malignancy, the use of stereotactic rather than surgical biopsy decreases the number of operations. Stereotactic 11-gauge vacuum-assisted biopsy, as compared with 14-gauge automated core or 14-gauge vacuum-assisted biopsy, is significantly more likely to spare a surgical procedure and has the highest cost savings.  相似文献   

7.
Learning curve for stereotactic breast biopsy: how many cases are enough?   总被引:5,自引:0,他引:5  
OBJECTIVE: The objective of this study was to evaluate the learning curve for stereotactic breast biopsy. MATERIALS AND METHODS: Retrospective review was performed of 923 consecutive lesions that underwent stereotactic breast biopsy performed by one of six radiologists. Four hundred fourteen lesions had 14-gauge automated core biopsy, and 509 subsequent lesions had vacuum-assisted biopsy (14-gauge in 163 and 11-gauge in 346). Medical records were reviewed to determine the technical success rate and false-negative rate as a function of operator experience. RESULTS: For 14-gauge automated core biopsy, a significantly lower technical success rate was seen for the first five cases of each radiologist than for subsequent cases (25/30 = 83.3% versus 366/384 = 95.3%, p < 0.02) and for the first 20 cases than for subsequent cases (90/100 = 90% versus 284/296 = 95.9%, p < 0.05). For 11-gauge vacuum-assisted biopsy, a significantly lower technical success rate was seen for the first five cases than for subsequent cases (17/20 = 85.0% versus 310/322 = 96.3%, p < 0.05) and for the first 15 cases than for subsequent cases (54/60 = 90.0% versus 273/283 = 96.5%, p = 0.03). The false-negative rate was higher for the first 15 cases compared with subsequent cases both for stereotactic 14-gauge automated core biopsy (4/31 = 12.9% versus 3/115 = 2.6%, p < 0.04) and for stereotactic 11-gauge vacuum-assisted biopsy (2/27 = 7.4% versus 0/85 = 0%, p < 0.06). CONCLUSION: A learning curve exists for stereotactic breast biopsy. Significantly higher technical success rates and lower false-negative rates were observed after the first five to 20 cases for 14-gauge automated core biopsy and after the first five to 15 cases for 11-gauge vacuum-assisted biopsy. Even after a radiologist has experience with stereotactic biopsy, changes in equipment may result in a new learning curve.  相似文献   

8.
OBJECTIVE: The purpose of our study was to determine the frequency with which stereotactic 11-gauge directional vacuum-assisted breast biopsy obviated a surgical procedure and to calculate cost savings attributable to that biopsy method. MATERIALS AND METHODS: We retrospectively reviewed 200 consecutive solitary nonpalpable lesions on which stereotactic 11-gauge directional vacuum-assisted breast biopsy was performed. Cost savings were calculated using Medicare reimbursements. Mammograms, histologic findings, and medical records were reviewed. RESULTS: Stereotactic 11-gauge directional vacuum-assisted biopsy obviated a surgical procedure in 151 (76%) of 200 lesions, including 112 (73%) of 154 calcific lesions and 39 (85%) of 46 masses. Reasons for not obviating a surgical procedure in 49 lesions (25%) included recommendation for surgical biopsy in 35 lesions (18%), small carcinomas treated by excision in 10 lesions (5%), and histologic underestimation in four lesions (2%). Stereotactic 11-gauge directional vacuum-assisted biopsy decreased the cost of diagnosis by S264 per case, a 20% ($264/$1289) decrease in the cost of diagnosis compared with surgical biopsy. Of 200 lesions that had stereotactic 11-gauge directional vacuum-assisted biopsy, 106 (53%) would not have been amenable to 14-gauge automated core biopsy because of their small size, their superficial location, or inadequate breast thickness. CONCLUSION: Stereotactic 11-gauge directional vacuum-assisted breast biopsy obviated a surgical procedure in 76% of lesions, yielding a 20% decrease in cost of diagnosis compared with surgical biopsy. Although savings per case are modest, 11-gauge directional vacuum-assisted biopsy expands the spectrum of lesions amenable to stereotactic biopsy, increasing cost savings in the population.  相似文献   

9.
Kim MJ  Kim EK  Lee JY  Youk JH  Park BW  Kim SI  Kim H  Oh KK 《European radiology》2007,17(9):2376-2383
The purpose of this study was to determine the frequency of carcinoma at percutaneous directional vacuum-assisted removal (DVAR) in women with imaging-histologic discordance during ultrasound (US)-guided automated core needle biopsy, and to determine the role of DVAR in breast lesions with imaging-histologic discordance. A US-guided 14-gauge automated core needle biopsy was performed on 837 consecutive lesions. Imaging-histologic discordance was prospectively considered in 33 of 634 benign biopsies. DVAR was recommended in those lesions. Among the 33 lesions, 26 lesions that underwent subsequent DVAR or surgical excision made up our study population. Medical records, imaging studies, and histologic findings were reviewed. Among the 26 lesions, 18 lesions underwent subsequent US–guided DVAR, with 8-gauge probes for 15 of the lesions, and 11-gauge for three of the lesions. Two lesions were diagnosed as having carcinoma (2/18, 11.1% of upgrade rate; 3.1–32.8% CI). The remaining eight lesions underwent subsequent surgical excision, and carcinoma was diagnosed in one case (12.5% of upgrade rate; 2.2–47.1% CI). A US-guided DVAR of the breast mass with imaging-histologic discordance during US-guided 14-gauge automated core needle biopsy is a valuable alternative to surgery as a means of obtaining a definitive histological diagnosis. An erratum to this article can be found at  相似文献   

10.
OBJECTIVE: We compared complication rates of core needle breast biopsy in patients with and without concurrent anticoagulation therapy. SUBJECTS AND METHODS: Experience with 501 14-gauge and 179 11-gauge core needle breast biopsies was recorded prospectively. We performed 18 (3%) of 680 procedures on patients undergoing anticoagulation therapy. Eleven biopsies were performed in eight women treated with warfarin, one in a patient treated with heparin, and six in six women treated with aspirin. Ten biopsies were performed with sonographic guidance and a 14-gauge automated biopsy gun. Eight biopsies were performed with an 11-gauge vacuum-assisted probe and stereotactic guidance. RESULTS: Hematomas occurred in three (38%) of eight anticoagulated patients undergoing 11-gauge vacuum-assisted stereotactic biopsy, measuring 13 mm, 17 mm, and 40 mm. In patients not known to be anticoagulated, small hematomas were mammographically evident in 77 (45%) of 171 biopsies performed with an 11-gauge probe, averaging 8 mm (range, 2-17 mm); only 13 (8%) of 171 had hematomas larger than 10 mm. Small hematomas, averaging 6 mm (range, 2-12 mm) were evident mammographically in 45 (45%) of 100 stereotactic biopsies using a 14-gauge automated biopsy gun; three (3%) experienced hematomas larger than 10 mm. A 10-mm hematoma was evident during one (10%) of the 10 biopsies performed in patients undergoing anticoagulation therapy under sonographic guidance using a 14-gauge automated biopsy gun; small hematomas (mean, 10 mm) were noted during seven (2%) of 391 corresponding sonographically guided biopsies in patients not undergoing anticoagulation therapy. CONCLUSION: No patients undergoing anticoagulation therapy experienced clinically important complications; preliminary results suggest rates of hematoma formation similar to those in the control group. As such, discontinuing anticoagulation medication before core needle breast biopsy may be unnecessary when the need for biopsy is urgent.  相似文献   

11.
Nonpalpable breast lesions: stereotactic automated large-core biopsies.   总被引:17,自引:0,他引:17  
One hundred two patients with mammographically suspicious, nonpalpable lesions underwent stereotactic breast biopsy with a biopsy gun and an automated 14-gauge cutting needle. After biopsy, a localization wire was placed and surgical biopsy performed. There was agreement of the histologic results from the gun biopsy and the surgical biopsy specimens in 98 cases (96%), including 22 of 23 carcinomas (96%) (kappa = 0.936). The gun biopsy yielded findings that led to the correct diagnosis in two cases involving lesions that were missed at surgical biopsy; two lesions found at surgery were missed at gun biopsy. The results of this study suggest that the use of 14-gauge needles improves agreement between surgical and needle core biopsy findings and that stereotactic biopsy with an automated needle and gun can be an acceptable alternative to surgical biopsy in women with mammographically suspicious breast lesions.  相似文献   

12.
AIM: To evaluate scar formation of impalpable breast lesions with benign histological outcome using stereotactic 11-gauge vacuum-assisted core biopsy (VACB). MATERIALS AND METHODS: Two hundred and ten lesions with benign histology for which follow-up mammograms were available, were assessed for scar formation at the biopsy site. All biopsies were performed using stereotactic VACB with 11-gauge needle. The incidence of post-biopsy scar formation and the number of specimens removed were determined. RESULTS: In 4.3% (9/210) of the lesions for which a biopsy was performed with 11-gauge directional vacuum-assisted technique, the follow-up mammogram revealed a scar formation. Of these, six were minimal scars, two were moderate scars and one was a marked scar. Minimal and moderate scars were diagnosed on imaging only. However, the case with marked scar formation required tissue diagnosis to rule out malignancy. CONCLUSION: Although uncommon, scar formation can be seen in the follow-up mammograms after percutaneous breast biopsies. It is important that the radiologist interpreting follow-up mammograms is aware of the features of this lesion and its relationship to the biopsy procedure.  相似文献   

13.
OBJECTIVE: The purpose of our study was to evaluate how often a mammographic abnormality thought to be produced by the biopsy procedure was evident on the initial follow-up mammogram after percutaneous biopsy of impalpable histologically benign lesions. We compared three stereotactic percutaneous biopsy methods. CONCLUSION: A mammographic density seen well only in the projection parallel to the biopsy needle tract was evident in 2% (5/226) of the lesions for which 11-gauge directional vacuum-assisted biopsy was used, 0% (0/96) of the lesions for which 14-gauge directional vacuum-assisted biopsy was used, and 0% (0/422) of the lesions for which 14-gauge automated large-core biopsy was used. No mammographic abnormalities assessed as BI-RADS categories 3, 4, or 5 (according to the American College of Radiology's Breast Imaging Reporting and Data System) and thought to be produced by the biopsy procedure were evident after any of the biopsy methods.  相似文献   

14.

Objective

We wanted to assess the need for surgical excising papillary lesions of the breast that were diagnosed upon sonographically guided 14-gauge core needle biopsy.

Materials and Methods

Sixty-nine women (age range: 25-74 years, mean age: 51.7 years) with 69 papillary lesions (4.9%) were diagnosed and followed after performing sonographically guided 14-gauge core needle biopsies. Surgical excision was performed for 44 (64%) of 69 papillary lesions, and 25 lesions were followed with imaging studies (range: 6-46 months, mean: 17.9 months). The histologic findings upon core biopsy were compared with the surgical, imaging and follow-up findings.

Results

Core needle biopsies of 69 lesions yielded tissue that was classified as benign for 43 lesions, atypical for 18 lesions and malignant for eight lesions. Of the 43 lesions that yielded benign papilloma upon core needle biopsy, one had intraductal papillary carcinoma found upon surgery. An immediate surgical biopsy was recommended for this lesion because of the imaging-histologic discordance. No additional carcinoma was found during the imaging follow-up. Surgical excision was performed for 17 atypical papillary lesions, and this revealed intraductal (n = 6) or invasive (n = 2) papillary carcinoma in 8 (47%) lesions. Of the seven intraductal papillary carcinomas, surgery revealed invasive papillary carcinoma in one (14%).

Conclusion

Our results suggest that papillary lesions of the breast that are diagnosed as benign upon sonographically guided 14-gauge core needle biopsy can be followed when the results are concordant with the imaging findings.  相似文献   

15.
The purpose of this study was to evaluate the diagnostic value of a self-contained battery-driven vacuum-assisted breast biopsy (VABB) system for the sampling of breast masses under ultrasound guidance. Sixty-five patients with 70 lesions underwent percutaneous 10-gauge ultrasound-guided VABB using the coaxial technique. In 38 lesions, subsequent surgery and comparison of histology was performed. The remaining 32 cases were followed-up and defined as true negative after a cancer-free interval of 24 months. VABB revealed malignant histology in 28 (40%) cases. Twenty-four malignancies were confirmed after surgery. Four invasive cancers verified in VABB were not found during surgery because they were completely removed, as proved by a disease-free interval of 24 months. One cancer missed in ultrasound-guided VABB due to its small size was successfully diagnosed with stereotactic VABB and thus turned out to be false negative, resulting in an overall sensitivity of 96.6%. Forty-one patients were free of cancer during the follow-up period of at least 24 months. In conclusion, the self-contained VABB device is well suited for ultrasound-guided breast biopsies.  相似文献   

16.
PurposeTo evaluate the performance of a self-contained, battery-driven, vacuum-assisted breast biopsy (VABB) system for the sampling of clustered breast microcalcifications and masses under stereotactic guidance.Methods and materialsA total of 144 patients (median age: 56 years; range: 21–87 years) in four European breast centers underwent percutaneous 9-gauge (G), stereotactic-guided VABB. The median lesion size was 11 mm (range 2–60 mm). Patients were biopsied in the prone (n=125) or upright position (n=19). All patients were followed up for at least 24 months.ResultsThe stereotactic procedure was successful in 142 (98.6%) of 144 cases, with two cases cancelled due to either severe patient motion (one case) or failure to detect faint calcifications (one case). A median of 12 specimens per procedure was obtained. In 39 cases (27.5%), the suspicious lesion could no longer be detected mammographically after the biopsy procedure. The histological diagnosis was malignancy in 45 (31.7%) cases. One case of atypical ductal hyperplasia diagnosed preoperatively was upgraded to ductal carcinoma in situ (DCIS) at operation, giving an overall sensitivity of 97.7% for the vacuum-assisted biopsy procedure. In two cases where DCIS was diagnosed at vacuum-assisted biopsy, the malignant tissue was apparently completely removed and could no longer be found at operation. No serious complications occurred. During the follow-up period, no breast cancers appeared at the location of biopsy. Six patients dropped out during the follow-up period.ConclusionThe self-contained, vacuum-assisted biopsy device is well suited for stereotactically guided breast biopsies, having demonstrated excellent sensitivity and specificity in the preoperative workup of mammographically detected breast lesions after 2 years of follow-up.  相似文献   

17.
Purpose: To evaluate a handheld vacuum-assisted device system for magnetic resonance image (MRI)-guided breast lesion biopsy.

Material and Methods: In 32 patients, a total of 42 suspicious breast lesions (mean diameter 7.5 mm for mass lesions, 11.6 mm for non-masslike diffuse lesions) seen with MRI (no suspicious changes in breast ultrasound or mammography) were biopsied (27 lateral, 15 medial) using a 10G vacuum-assisted breast biopsy device under MR guidance. Histology of biopsy specimens was compared with final histology after surgery or follow-up in benign lesions.

Results: In all biopsies, technical success was achieved. Histology revealed 11 lesions with ductal carcinoma in situ (DCIS) or invasive cancer, three with intermediate lesions (LCIS) and 28 with benign breast lesions (adenosis, infected hematoma). In one patient with discordant results of MRI and histology, surgical excision revealed medullary cancer. In the follow-up (mean 18 months) of the histological benign lesions, no breast cancer development was observed. Besides minor complications (hematoma, n = 6), with no further therapeutic interventions, no complications occurred.

Conclusion: MRI-guided breast lesion biopsy using a handheld vacuum-assisted device is a safe and effective method for the work-up of suspicious lesions seen with breast MRI without changes in mammography or ultrasound. In the case of discordant histology of vacuum biopsy and breast MRI appearance, surgical excision is recommended.  相似文献   

18.
目的:评价在空心针活检(core needle biopsy,CNB)病理结果与超声诊断存在差异的乳腺占位性病变中,真空辅助活检(vacuum-assisted biopsy,VAB)是否可获得准确的病理结果,产生病理升级。材料和方法:2007-01~2008-06,对接受16GCNB的969例患者的1069个病灶进行超声诊断及穿刺病理分析。其中,28个病灶超声诊断为可疑恶性,但CNB活检得到非恶性结果,采用真空辅助活检系统再次活检。所有VAB证实为良性的病灶均需要临床随访1年以上,所有VAB证实为恶性的病灶均需与手术病理对比分析。结果:本组中,28个病灶的CNB病理诊断与超声诊断存在差异,占2.6%(28/1069)。28个病灶中,VAB再次活检证实6个病灶存在病理升级,占21.4%(6/28)。其中,1例由腺病升级为导管内癌(ductal carcinoma insitu,DCIS),1例由腺病升级为浸润性导管癌(infitrating ductal carcinoma,IDC),1例由不典型导管增生(atypical ductal hyperplasia,ADH)升级为IDC,2例由导管内乳头状瘤升级为DCIS,1例由硬化性腺病升级为浸润性小叶癌(infiltrating lobular carci-noma,ILC)。结论:真空辅助活检系统的出现,大大提高了样本的取材量,提高了诊断的准确性。其在评价CNB与超声诊断存在差异的病例中可获得更为准确的病理结果,产生病理升级。  相似文献   

19.

Objective

To evaluate the diagnostic accuracy of the use of an ultrasonography (US)-guided vacuum-assisted biopsy for microcalcifications of breast lesions and to evaluate the efficacy of the use of US-guided vacuum-assisted biopsy with long-term follow-up results.

Materials and Methods

US-guided vacuum-assisted biopsy cases of breast lesions that were performed between 2002 and 2006 for microcalcifications were retrospectively reviewed. A total of 62 breast lesions were identified where further pathological confirmation was obtained or where at least two years of mammography follow-up was obtained. These lesions were divided into the benign and malignant lesions (benign and malignant group) and were divided into underestimated group and not-underestimated lesions (underestimated and not-underestimated group) according to the diagnosis after a vacuum-assisted biopsy. The total number of specimens that contained microcalcifications was analyzed and the total number of microcalcification flecks as depicted on specimen mammography was analyzed to determine if there was any statistical difference between the groups.

Results

There were no false negative cases after more than two years of follow-up. Twenty-nine lesions were diagnosed as malignant (two invasive carcinomas and 27 carcinoma in situ lesions). Two of the 27 carcinoma in situ lesions were upgraded to invasive cancers after surgery. Among three patients diagnosed with atypical ductal hyperplasia, the diagnosis was upgraded to a ductal carcinoma in situ after surgery in one patient. There was no statistically significant difference in the number of specimens with microcalcifications and the total number of microcalcification flecks between the benign group and malignant group of patients and between the underestimated group and not-underestimated group of patients.

Conclusion

US-guided vacuum-assisted biopsy can be an effective alternative to stereotactic-guided vacuum-assisted biopsy in cases where microcalcifications are visible with the use of high-resolution US.  相似文献   

20.
OBJECTIVE: To assess the ultrasonographic features of post-biopsy change 6 months after 11-gauge vacuum-assisted large-core breast biopsy of pathologically proven benign lesions. Using the literature as a reference, we hypothesized that large-core breast biopsy would result in tissue changes that may mimic malignancy and may be more apparent on ultrasonography than on mammography. METHODS: Two radiologists whose subspecialty is breast imaging retrospectively reviewed the pre-biopsy and 6-month follow-up sonograms of 24 patients with pathologically proven benign lesions. The images were assessed for the number and type of ultrasonographic features. A Breast Imaging Reporting and Data System (BI-RADS) category was assigned to each lesion before biopsy and at 6-month follow-up. The composition of breast tissue surrounding the lesion was assessed as fatty, mixed fibroglandular or dense. RESULTS: The frequency of ultrasonographic changes at 6 months after 11-gauge vacuum-assisted large-core breast biopsy was more frequent than the rate of post-biopsy change previously reported to occur mammographically. The nature of these changes may mimic malignancy in some cases. CONCLUSION: The ultrasonographic appearance of the breast after large-core breast biopsy may mimic malignancy and is, therefore, a potential pitfall when interpreting a post-biopsy sonogram.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号