首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到2条相似文献,搜索用时 0 毫秒
1.
The amino acid derivative reactivity assay (ADRA) is an in chemico alternative to animal testing for skin sensitization that solves certain problems found in the use of the direct peptide reactivity assay (DPRA). During a recent validation study conducted at multiple laboratories as part of the process to include ADRA in an existing OECD test guideline, one of the nucleophilic reagents used in ADRA—N‐(2‐(1‐naphthyl)acetyl)‐l ‐cysteine (NAC)—was found to be susceptible to oxidation in much the same manner that the cysteine peptide used in DPRA was. Owing to this, we undertook a study to clarify the cause of the promotion of NAC oxidation. In general, cysteine and other chemicals that have thiol groups are known to oxidize in the presence of even minute quantities of metal ions. When metal ions were added to the ADRA reaction solution, Cu2+ promoted NAC oxidation significantly. When 0.25 μm of EDTA was added in the presence of Cu2+, NAC oxidation was suppressed. Based on this, we predicted that the addition of EDTA to the NAC stock solution would suppress NAC oxidation. Next, we tested 82 chemicals used in developing ADRA to determine whether EDTA affects ADRA's ability to predict sensitization. The results showed that the addition of EDTA has virtually no effect on the reactivity of NAC with a test chemical, yielding an accuracy of 87% for predictions of skin sensitization, which was roughly the same as ADRA.  相似文献   

2.
The amino acid derivative reactivity assay (ADRA) is an in chemico alternative method that focuses on protein binding as the molecular initiating event for skin sensitization. It is a simple and versatile method that has successfully solved some of the problems of the direct peptide reactivity assay (DPRA). The transferability and within‐ and between‐laboratory reproducibility of ADRA were evaluated and confirmed as part of a validation study conducted at four participating laboratories. The transfer of ADRA technology from the lead laboratory to the four participating laboratories was completed successfully during a two‐step training program, after which the skin sensitization potentials of 40 coded chemicals were predicted based on the results of ADRA testing. Within‐laboratories reproducibility was 100% (10 of 10), 100% (10 of 10), 100% (7 of 7) and 90% (9 of 10), or an average of 97.3% (36 of 37); between‐laboratory reproducibility as calculated on the results of three laboratories at the time was 91.9%. The overall predictive capacity comprised an accuracy of 86.9%, sensitivity of 81.5% and specificity of 98.1%. These results satisfied the targets set by the validation management team for demonstrating transferability, within‐ and between‐laboratory reproducibility, and predictive capacity as well as gave a clear indication that ADRA is easily transferable and sufficiently robust to be used in place of DPRA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号