首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Background: Recent concepts about cerebrospinal fluid (CSF) circulation in communicating hydrocephalus (CoHy), which is also termed “restricted arterial pulsation hydrocephalus,” suggest reduced arterial pulsations of subarachnoid vessels with a smaller amount of CSF shifted in subarachnoid spaces during the early systole. The postulated restriction of subarachnoid arterial pulsations in CoHy should induce a smaller motion artifact and reduced local stream effects in CSF in magnetic resonance (MR) diffusion-weighted imaging (DWI).

Purpose: To investigate the maximum diffusivity in CSF in patients with and without CoHy using DWI.

Material and Methods: 12 patients without CSF circulation disturbances and six cases with proven CoHy were assessed. Diffusion was measured in six noncollinear directions without triggering the arterial pulse wave (scan time 6:45 min, voxel size 2×2×2 mm). Due to expected artifacts, the calculated maximum diffusivity was called apparent diffusivity. Regional high and low apparent diffusivity was assessed in CSF spaces on newly created 3D CSF motion maps.

Results: Patients with regular CSF circulation exhibited high apparent diffusivity in CSF in basal subarachnoid spaces, whereas apparent diffusivity was low there in patients with CoHy.

Conclusion: DWI opens a feasible approach to study CSF motion in the neurocranium. Restricted arterial pulsations seem to be involved in CoHy.  相似文献   

2.
Purpose: To investigate the accuracy of dedicated pancreatic multidetector computed tomography (MDCT) in the diagnosis of neuroendocrine pancreaticoduodenal tumors (NPTs).

Material and Methods: MDCT and other imaging studies in patients with suspected NPTs were identified. Thirty dedicated MDCT studies were done in 23 patients. Fourteen patients (16 operations) subsequently had surgery. Imaging reports were reviewed and findings compared with surgical findings and findings in other imaging studies.

Results: Patients with surgery: 19 NPTs (16 extrapancreatic gastrinomas and 3 pancreatic NPTs) were identified at surgery. MDCT identified 16 and somatostatin receptor scintigraphy (SRS) 11 out of 19 tumors. Endoscopic ultrasound detected 11 out of 14 NPTs. Patients without surgery: In 4 out of 9 patients, no NPTs were identified at MDCT.

Conclusion: Dedicated MDCT of the pancreas can identify many NPTs, including small duodenal and periduodenal tumors, and the detection rate is better than reported in the older literature on CT.  相似文献   

3.
Background: The introduction of multidetector-row computed tomography (MDCT) has revolutionized the initial management of multiply injured patients. This technology has the potential to improve the imaging of traumatic vascular injuries.

Purpose: To evaluate the quality of multidetector-row computed tomography angiography (MDCTA) of the carotid arteries in the setting of a routine whole-body trauma scan.

Material and Methods: 87 trauma patients underwent a routine whole-body CT scan in a 16-detector-row scanner including an MDCTA with a reconstructed axial slice thickness of 3 mm. Images were reviewed by three experienced radiologists with emphasis on image quality. Contrast density, severity, and origin of artifacts and the occurrence of vessel lesions were assessed for different vessel segments.

Results: 3642 separate vessel segments were evaluated. Contrast density was rated good or sufficient for diagnosis in 99.8%. A total of 67.3% of vessel segments were free of artifacts, while 27.9% of vessel segments showed minor artifacts not impairing diagnostic evaluation. Clinically relevant artifacts obscuring a vessel segment occurred in 4.7% and were mostly caused by dental hardware. Four dissections of the internal carotid artery were diagnosed by all three radiologists.

Conclusion: As a rapid screening test for blunt carotid artery injury, integration of MDCTA in the routine imaging workup of trauma patients utilizing a whole-body CT trauma scan is possible and practicable. Image quality is mostly sufficient for diagnosis, but impaired in a few cases by artifacts deriving primarily from dental hardware.  相似文献   

4.
Purpose: To investigate the angulation, length, and structural variations of the styloid process (SP) by multidetector computed tomography (MDCT).

Material and Methods: MDCT scans were performed in 283 cases (127 M and 156 F, age range 18-77 years). The length of the SP and its angulation on the transverse and sagittal planes were measured. Structural variations of the SP were observed by means of three-dimensional (3D) and multiplanar reconstruction (MPR) images.

Results: The length of the bony SP on both sides varied from 0 to 62 mm (mean 26.8±10.0 mm). Angulation ranged between 55° and 90.5° (7 2.7±6.6) in the transversal plane and between 76° and 110° (93.5±6.9) in the sagittal plane. Morphologically, the SP showed a considerable amount of variation. A solitary SP was present in 168 individuals (59.4%). In 9 individuals (3.1%), the SP was duplicated (4 unilateral and 5 bilateral). Sixty-one persons (21.6%) showed an incomplete ossified SP (42 unilateral and 19 bilateral), whereas in 7 individuals (2.5%) a bony SP was absent entirely (7 unilateral). In 38 individuals (13.4%), the stylohyoid ligament was ossified (16 entirely, 22 partial). In all individuals, 3D and MPR images showed the SP in its entire length.

Conclusion: MDCT with 3D CT and MPR of SP may show further detailed information related to SP. Not only the length of the SP, but also its 3D orientation, should be in focus in anatomical and clinical studies.  相似文献   

5.
Purpose: To investigate whether improvements in signal-to-noise ratio (SNR) and spectral resolution are found in spectra from patients with brain metastases obtained at higher magnetic field strengths using standard clinical instrumentation.

Material and Methods: Six patients with brain metastases, 13 healthy volunteers, and a phantom containing brain metabolites were examined using two clinical MR instruments operating at 1.5T (Siemens) and 3T (Philips) with standard clinical head coils. Spectra were obtained using a point resolved spectroscopy pulse sequence, echo times (TE) 32 ms and 144 ms, and repetition time 2000 ms from a volume-of-interest (VOI) of size 15×15×15 mm3. SNR and spectral resolution of the metabolites N-acetylaspartate, choline, and creatine compounds in spectra from 3T were compared to the 1.5T spectra.

Results: In general, spectral resolution was improved by 25-30% at higher magnetic field strength. Only minor improvements in SNR were obtained at 3T using short echo time and 20-50% at long echo time.

Conclusion: SNR and spectral resolution were improved at higher magnetic field strength, especially with TE 144 ms, including spectra from patients with heterogeneous brain tumors. However, differences in the defined effective VOI, particularly at short echo time, reduced the expected effect of increased magnetic field strength on the measured SNR.  相似文献   

6.
Purpose: To compare radiation doses given to patients undergoing IVU (intravenous urography) before and after digitalization of our X-ray department.

Material and Methods: IVU examinations were monitored with dose area product meters before and after the X-ray department changed to digital techniques. The first step was a change from film-screen to storage phosphor plates, while the second step involved changing to a flat panel detector. Forty-two patients were included for the film-screen situation, 69 when using the storage phosphor plates, and 70 using the flat panel detector.

Results: A dose reduction from 41.8 Gycm2 to 31.5 Gycm2 was achieved with the first step when the film-screen system was replaced with storage phosphor plates. A further reduction to 12.1 Gycm2 was achieved using the flat panel detector.

Conclusion: The introduction of the flat panel detectors made a considerable dose reduction possible.  相似文献   

7.
Background: The range of the diameters of pulmonary arteries (PA) is not fully shown in the current literature. Contrast-enhanced computed tomography (CT) of the thorax might be used for measuring diameters of the PA.

Purpose: To determine the diameters of PAs in subjects with normal PA pressure by using thoracic CT.

Material and Methods: 126 subjects aged between 19 and 46 years, having normal thoracic CTs (5-mm slice thickness) and normal PA pressures (≤25 mmHg, determined by echocardiography), were included in the study. The diameters of the main, right, and left PAs were measured by using multidetector CT.

Results: The main PA diameters of all the subjects showed a normal distribution, and the mean was 24.0±2.8 mm. The main PA diameters in male and female subjects also showed a normal distribution. The difference between the sexes for the main PA diameters was not significant (P = 0.08). There were correlations between main PA diameter and body-mass index (BMI) (R = 0.41, P = 0.001) and weight (R = 0.34, P = 0.001). However, there was no significant correlation between main PA diameter and height (R = 0.05, P = 0.6).

Conclusion: This study suggests that diameters of the main PA and its main branches show a normal distribution in subjects having normal PA pressures. Based on our findings, the upper limits of the main, right, and left PA diameters are 29.5 mm, 19.8 mm, and 22.1 mm, respectively, in healthy adults.  相似文献   

8.
Background: Multidetector computed tomography (MDCT) enterography combines neutral enteric contrast with intravenously administered contrast material. The optimal intravenous (IV) contrast material protocol has still not been established.

Purpose: To determine the optimal delay time to image patients with small-bowel Crohn's disease during MDCT enterography.

Material and Methods: After oral administration of 1350 ml of neutral contrast medium, 26 patients with small-bowel Crohn's disease underwent MDCT enterography; scans were obtained 40 s (enteric phase) and 70 s (parenchymal phase) after IV administration of 100 ml of iodinated contrast material. Three radiologists, blinded to clinical and pathological findings, independently and retrospectively evaluated each scan in two separate reading sessions for the presence or absence of CT features of Crohn's disease activity. The interobserver agreement was evaluated, and the efficacy of each phase in detecting active disease in the terminal ileum for each reader was determined. The gold standard was pathology (n = 13), endoscopy (n = 3), and clinical evaluation (n = 10).

Results: No statistically significant difference was present between the enteric and the parenchymal phase for each reader in each segment regarding the presence or absence of CT features of Crohn's disease. The interobserver agreement for the presence of five main features of active Crohn's disease in the terminal ileum ranged from poor to excellent. The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for active Crohn's disease in the terminal ileum ranged from 40 to 90%, 88 to 100%, 70 to 94%, 44 to 100%, and 69 to 96%, respectively. There was no statistical difference between the two phases for each reader.

Conclusion: MDCT enterography in patients with suspected active Crohn's disease can be obtained at either 40 s or 70 s after IV contrast material.  相似文献   

9.
Purpose: To investigate the prevalence of renal artery aneurysms, and to assess the value of multidetector-row computed tomography (MDCT) in diagnosing renal artery aneurysms.

Material and Methods: Altogether, 862 patients underwent arterial-phase contrast-enhanced CT scan of the abdomen in the period November 2003 to October 2005. A search for renal artery aneurysms was performed in our reporting system and revealed six patients with renal artery aneurysm (RAA).

Results: The incidence of RAA was 0.7%. All renal artery aneurysms were solitary, located in the main trunk or the first branch of the renal artery, with sizes from 1.5 cm to 3.4 cm. Five aneurysms were saccular, one fusiform. No underlying thrombosis was seen. Extensive calcification was found in one aneurysm. Three aneurysms were diagnosed using axial images, while three aneurysms were only displayed by volume rendering and maximum-intensity projection images.

Conclusion: This study demonstrates a 0.7% incidence of renal artery aneurysms in a total of 862 patients. MDCT has an important role in detecting and assessing renal artery aneurysms. Some aneurysms can only be displayed by post-processing techniques such as volume rendering and maximum-intensity projection.  相似文献   

10.
Purpose: To evaluate the ability of multi-detector row computed tomography angiography (CTA) in detecting hepatic artery complications in the follow-up of liver transplant patients, performing volume-rendering as reconstruction technique.

Material and Methods: The anatomy of hepatic artery was studied in 27 liver transplant recipients with a four-row CT scanner using the following parameters: collimation, 1 mm; slice width, 1 mm; table feed, 6-8 mm/s; spiral reconstruction time, 0.5 s; reconstruction interval, 0.5 mm; mAs, 160; kVp, 120. Before the study, the patients received 1000 ml of water as oral contrast agent to produce negative contrast in the stomach and the small bowel. A non-ionic contrast medium was infused intravenously at a rate of 5 ml/s with a bolus tracking system. Volume-rendering of hepatic artery was performed with the 3D Virtuoso software.

Results: The celiac trunk, the hepatic artery, and the right and left hepatic arteries were successfully displayed in high detail in all patients. Side branches, including small collaterals, and hepatic artery anastomosis could also be readily visualized. Volume-rendered CTA detected six hepatic artery stenoses, two hepatic artery thromboses, and two intrahepatic pseudoaneurysms. In two cases, CT detected hepatic artery stenosis with a diameter reduction of less than 50%, while digital subtraction angiography showed a normal artery.

Conclusion: Volume-rendered multi-detector CTA is a promising non-invasive technique, since it allows images of high quality to be generated with excellent anatomical visualization of the hepatic artery and its complications in liver transplant recipients.  相似文献   

11.
Background: The differential diagnosis of parotid gland tumors is often difficult with conventional magnetic resonance imaging.

Purpose: To determine whether the calculation of the apparent diffusion coefficient (ADC) is valuable for making the differential diagnosis of parotid tumors.

Material and Methods: Thirty parotid masses in 28 patients and 24 healthy parotid glands in 12 controls were examined in this prospective study. Diffusion-weighted magnetic resonance imaging with echo-planar spin-echo sequences was used to evaluate each subject. The ADC of each tumor and each healthy parotid gland was calculated. Tumor diagnoses were confirmed by the results of histopathologic analysis.

Results: The following types of masses were identified: 11 Warthin tumors, nine pleomorphic adenomas, seven malignant tumors, one basal cell adenoma, and two benign cysts. The mean ADC value for the Warthin tumors was 0.97±0.16×10-3 mm2/s, for the pleomorphic adenomas was 1.74±0.37×10-3 mm2/s, for the malignant tumors was 1.04±0.35×10-3 mm2/s, and for the normal parotid glands was 0.34±0.20×10-3 mm2/s. The respective ADC value for the single basal cell adenoma was 1.40×10-3 mm2/s. Statistically significant differences were identified between the subjects with pleomorphic adenoma and those with another type of parotid tumor, and between subjects with healthy parotid glands and those with a tumor.

Conclusion: Calculating the ADC appears to be useful in differentiating pleomorphic adenomas from other types of parotid gland tumors.  相似文献   

12.
Background: A method to describe pelvic rotations between pairs of standard sequential pelvic anteroposterior radiographs based on a pelvic phantom is described in a former study.

Purpose: To expand this method into clinical use based on clinical data.

Material and Methods: Teardrop distances were measured on 262 pelvic radiographs from 46 patients in a clinical material using a computer program designed to perform measurements on digital radiographs. Anthropometric data recorded from 141 pelvises in an anatomical collection were employed in a computer program designed to simulate radiographs of virtual objects. Virtual rotations of the pelvises were carried out with 4653 virtual radiographs obtained. Virtual radiographic measures were analyzed.

Results: A statistically significant difference of 8 mm between mean teardrop distance in females (120 mm) and males (112 mm) was found in the clinical material. A set of formulas describing the relations between differences of two rotation ratios and pelvic rotations were derived. Four simple regression analyses were carried out with the use of virtual measures. Adjusted teardrop distances were implemented.

Conclusion: A clinical method to describe pelvic rotations using standard pelvic radiographs was developed.  相似文献   

13.
Background: Detection of colorectal tumors with computed tomography colonography (CTC) is an alternative to conventional colonoscopy (CC), and clarification of the diagnostic performance is essential for cost-effective use of both technologies.

Purpose: To evaluate the diagnostic performance of CTC compared with CC.

Material and Methods: 231 consecutive CTCs were performed prior to same-day scheduled CC. The radiologist and endoscopists were blinded to each other's findings. Patients underwent a polyethylene glycol bowel preparation, and were scanned in prone and supine positions using a single-detector helical CT scanner and commercially available software for image analysis. Findings were validated (matched) in an unblinded comparison with video-recordings of the CCs and re-CCs in cases of doubt.

Results: For patients with polyps ≥5 mm and ≥10 mm, the sensitivity was 69% (95% CI 58-80%) and 81% (68-94%), and the specificity was 91% (84-98%) and 98% (93-100%), respectively. For detection of polyps ≥5 mm and ≥10 mm, the sensitivity was 66% (57-75%) and 77% (65-89%). A flat, elevated low-grade carcinoma was missed by CTC. One cancer relapse was missed by CC, and a cecal cancer was missed by an incomplete CC and follow-up double-contrast barium enema.

Conclusion: CC was superior to CTC and should remain first choice for the diagnosis of colorectal polyps. However, for diagnosis of lesions ≥10 mm, CTC and CC should be considered as complementary methods.  相似文献   

14.
Purpose: To determine the benefits of submillimeter coronary computed tomography (CT) angiography in vitro.

Material and Methods: The coronary arteries of three domestic pigs were filled with contrast agent and depicted with clinically applicable CT angiography protocols with a slice thickness of 0.63 to 2.5 mm.

Results: With 2.5 mm slices, only the third-degree coronary artery branches could be discerned. With 1.25 mm slices, some fourth-degree branches of the right coronary artery could be discerned upon maximum intensity projections. With 0.63 mm slices, fourth-degree coronary artery branches could be discerned in all locations.

Conclusion: The introduction of 16-row detector CT with submillimeter z-axis resolution translates into an order-of-magnitude benefit for the depiction of coronary artery branches.  相似文献   

15.
Background: Hookwire localization is the current standard technique for radiological marking of nonpalpable breast lesions. Stereotactic directional vacuum-assisted breast biopsy (SVAB) is of sufficient sensitivity and specificity to replace surgical biopsy. Wire localization for metallic marker clips placed after SVAB is needed.

Purpose: To describe a method for performing computed tomography (CT)-guided hookwire localization using a radial approach for metallic marker clips placed percutaneously after SVAB.

Material and Methods: Nineteen women scheduled for SVAB with marker-clip placement, CT-guided wire localization of marker clips, and, eventually, surgical excision were prospectively entered into the study. CT-guided wire localization was performed with a radial approach, followed by placement of a localizing marker-clip surgical excision. Feasibility and reliability of the procedure and the incidence of complications were examined.

Results: CT-guided wire localization surgical excision was successfully performed in all 19 women without any complications. The mean total procedure time was 15 min. The median distance on CT image from marker clip to hookwire was 2 mm (range 0-3 mm).

Conclusion: CT-guided preoperative hookwire localization with a radial approach for marker clips after SVAB is technically feasible.  相似文献   

16.
Purpose: To establish whether information would be lost if slice reconstruction thickness was increased from 3 to 5 mm, and whether this altered how difficult it was to interpret the examinations.

Material and Methods: Twenty-three consecutive patients referred with suspected or known urinary stones were included. All examinations were performed without intravenous contrast media. The original series, with effective mAs 50, were reconstructed with slice thickness 3 and 5 mm, respectively. All demographic and examination data were removed and the series reviewed in PACS by two independent radiologists. Objective findings, i.e. number and size of stones, signs of obstruction, and evaluation of interpretation difficulty, were registered.

Results: Identical findings were registered in 18 of the series of 3 mm (n = 23) and 19 of the series of 5 mm (n = 23). In two series reconstructed with 3 mm slice thickness and in one series with 5 mm slice thickness, the observers disagreed on the presence of urinary stones. Main reasons for interpretation difficulties were given as “lack of intra-abdominal fat” and “many phleboliths in the pelvic region”, but never “disturbing noise”.

Conclusion: To determine the presence and size of urinary stones at low-dose computed tomography, 5 mm reconstruction algorithm seems equal to 3 mm. Patient-related factors influence the interpretation more than image quality.  相似文献   

17.
Purpose: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging (MRI) compared to arthroscopy in the detection of meniscal lesions.

Material and Methods: In a prospective study, 31 knee joints were imaged on a 1.5T MR scanner before arthroscopy using the following sequences: (a) coronal and sagittal FS-PDw TSE (TR/TE: 4009/15 ms); (b) coronal T1w SE (TR/TE: 722/20 ms), and sagittal PDw TSE (TR/TE: 3800/15 ms). Other imaging parameters were: slice thickness 3 mm, FOV 160 mm, matrix 256×256. A total of 186 meniscal regions (62 menisci; anterior horn, body, posterior horn) were evaluated. Standard of reference was arthroscopy. Sensitivity, specificity, negative predictive value (npv), positive predictive value (ppv), and accuracy were calculated.

Results: Arthroscopically, meniscal lesions were detected in 55/186 segments (35 medial and 20 lateral meniscal lesions). Sensitivity, specificity, npv, ppv, and accuracy for combination of coronal and sagittal FS PDw TSE were 91.4%, 98.3%, 95%, 97%, and 93.5% for the medial meniscus, and 90%, 98.6%, 97.3%, 94.7%, and 96.8% for the lateral. The results were comparable to the combination of coronal T1w SE and sagittal PDw TSE for the medial (88.6%, 98.3%, 93.4%, 96.9%, 91.4%) and the lateral (90%, 95.9%, 97.2%, 85.7%, 92.5%) meniscus.

Conclusion: FS PDw TSE-MR sequences are an excellent alternative for the detection of meniscal lesions in comparison with diagnostic arthroscopy.  相似文献   

18.
3D imaging of the whole spine at 3T compared to 1.5T: initial experiences   总被引:2,自引:0,他引:2  
Purpose: To describe our first experiences with a recently introduced 3T system for T2-weighted isotropic 3D whole-spine imaging.

Material and Methods: Magnetic resonance imaging of the whole spine was performed by implementing an isotropic 3D fast spin-echo sequence with variable flip-angle refocusing pulses at 3T and 1.5T. Signal-to-noise ratio (SNR) was compared on both systems in eight subjects.

Results: Mean values for SNR were significantly higher at 3T (346±214) for 1.0 mm voxel size compared to 1.5T (202±41), but showed considerably higher variability at 3T. At 3T, measurements with 0.9 mm voxel size were possible with similar SNR as with 1.0 mm voxel size at 1.5T.

Conclusion: High-resolution 3D imaging of the whole spine is feasible at 3T with an increased SNR compared to 1.5T. Signal gain at 3T can be used to further increase spatial resolution. Pronounced interpatient variability of SNR at 3T may be a result of inhomogeneous RF deposition due to dielectric effects.  相似文献   

19.
Background: Renal artery stenosis may produce hypertension, and this condition is referred to as renovascular hypertension (RVH).

Purpose: To evaluate, by using multidetector-row spiral computed tomographic angiography (MDCTA), whether a relationship between accessory renal artery stenosis and hypertension may be hypothesized.

Material and Methods: 214 patients (142 males, 72 females; mean age 66 years) who had previously undergone an MDCTA to study the abdominal vasculature were retrospectively studied. Patients with renal artery stenosis (RAS) were excluded from this analysis. The patients were studied by means of a four-detector-row CT, and scans were obtained after intravenous bolus administration of 110-140 ml of a nonionic contrast material with a 3-6 ml/s flow rate. As a second step, by means of statistical analysis, hypertension data were compared with findings of accessory artery stenosis. Two radiologists first independently reviewed the MDCTA images and then, in case of disagreement, in consensus. Interobserver agreement was calculated for all measurements.

Results: The overall number of detected accessory renal arteries was 74 in 56 of the 214 patients. Accessory renal artery stenosis was detected in 21 of the 56 patients. There was a difference in the prevalence of hypertension between patients with (n = 21) and without (n = 35) accessory renal artery stenosis (P = 0.0187). Interobserver agreement was good (kappa value 0.733).

Conclusion: Any statistical association between the presence of accessory renal artery stenosis and hypertension could not be disclosed. However, accessory renal artery stenosis, detected by MDCTA, is an important pathological sign that the radiologist has to assess in the light of its possible association with hypertension.  相似文献   

20.
Purpose: To determine the in vivo precision and accuracy of magnetic resonance imaging (MRI) in evaluating the thin (~mm) femoral neck cortex.

Material and Methods: Hip regions of 30 volunteers were scanned with standard 1.5T MRI twice with repositioning, and the images of the narrow-neck cross-sections were obtained. Two radiologists independently delineated periosteal and endosteal cortical boundaries, and several structural variables were determined. For precision, 95% limits of agreement and coefficients of variation were calculated. Accuracy was determined with phantoms.

Results: In vivo precision of the directly delineated measurements varied from 0.9% (periosteal circumference) to 1.6% (total area), while the precision of the calculated variables remained poorer, from 7.3% (cortical to total area ratio) to 15.1% (torsional rigidity). The root-mean-square error of the cortical thickness measurement was 0.15 mm.

Conclusion: Thin cortical bone at the narrowest location of the femoral neck can be delineated precisely and accurately with a standard clinical 1.5T MRI device. MRI provides a feasible tool for the assessment of mechanically important cortical bone at the femoral neck and may be of clinical utility in assessing hip fragility.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号