首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.

Introduction

Periprosthetic fractures of the proximal femur place a significant burden on the patients who endure them, as well as the medical health system that supports them. The purpose of this study was to determine whether femoral cortical thickness, as an absolute measurement, is a predictor of periprosthetic fracture pattern.

Method

A cohort of 102 patients who had sustained a periprosthetic hip fracture were retrospectively identified. This included 58 males and 44 females with a mean age of 79.8 years. The femoral periprosthetic fracture pattern was classified based on the Vancouver classification system. Stem fixation was recorded and femoral cortical thickness measured. Patients were grouped into cemented and cementless stems. The relationship between cortical thickness and periprosthetic fracture pattern was assessed using the primary stem fixation method. Receiver operating characteristic (ROC) curve analysis was used to identify a threshold in the cortical thickness that predicted fracture pattern. Multinomial logistic regression analysis was used to adjust for confounding variables to assess the independent influence of cortical thickness on the risk of sustaining a Vancouver type A, B or C.

Results

There were 65 (63.7%) patients in the cemented group and 37 (36.3%) in the cementless group. The pattern of periprosthetic fractures around cemented stems was significantly (p < 0.001) influenced by the femoral cortical thickness, with a thinner cortical thickness associated with a type A fracture pattern. In contrast, no association between femoral cortical thickness and fracture pattern assessment was demonstrated in the cementless group (p = 0.82 Chi square). Comparing the rate of type A fracture patterns between the groups illustrated a significantly decreased risk in the cemented group with a cortical thickness of > 7 mm (odds ratio 0.03, p < 0.001). ROC curve analysis of the cemented group demonstrated a threshold value of 6.3 mm, offering a sensitivity of 83.3% and a specificity of 78.9% in predicting an A type fracture. Using this threshold, patients with a cortical thickness of 6.3 mm or less were significantly more likely to sustain a Vancouver type A fracture (OR 18.9, 95% CI 2.0–166.7, p < 0.001) when compared to patients with a cortical thickness of > 6.3 mm. In contrast, the ROC curve analysis did not find cortical thickness to be a predictor of fracture pattern in the cementless group. When adjusting for confounding variables, multinomial logistic regression demonstrated a cortical thickness of 6.3 mm or less was a significant predictor of a type A fracture (OR 3.28, 95% CI 1.06–10.16, p = 0.04) relative to those sustaining a type B fracture.

Conclusion

Cortical thickness was found to influence the periprosthetic fracture pattern around cemented femoral stems, but this was not observed with cementless stems. Type A fracture patterns were significantly more likely to occur with a cortical thickness of 6.3 mm or less around cemented stems.
  相似文献   

2.

Background

Distal femoral endoprosthesis (DFE) has become the optimal method of reconstruction in the skeletally mature patients treated for malignant bone tumor. Albeit literature has reported wide range of aseptic loosening in cemented components (6–32%), few authors showed that cement was not detrimental to long-term success of primary distal femoral implants possibly relating to cementing technique.

Methods

A series of consecutive of DFE (MRS and GMRS, Styker Orthopaedics, Mahwah, NJ) was retrospectively reviewed for evidence of loosening on plain radiographs. All prostheses had the standard straight 127-mm stem and a cemented polyethylene tibial component. Cementing technique involved reaming line to line to the selected stem size and cementing without pressurization. Radiographs were assessed by two independent blinded reviewers and scored for radiolucent zones (>1 mm) and graded as not loose, possibly, probable and definite loose. Furthermore, the final reamer/stem diameters, length of resection, tumor type, adjuvant treatment modalities, bushing exchange/revision surgery and infection rate were recorded.

Results

There were 70 patients and none were lost to follow-up. The average radiographic follow-up was 7.2 years (58% had f/u >5 years). Examiner A found 89% of femoral components to be “Not Loose” and 11% (n = 6) “Possibly Loose”. Examiner B found 96% of femoral components to be “Not Loose” and 4% (n = 2) to be “Possibly Loose”. No components scored as probably or definitely loose. Two DFE stems were reported as “Possibly Loose” by both reviewers. No femoral stem required revisions for either loosening, femur fracture or metal failure. Although infection was frequent, there was no septic loosening.

Conclusion

Despite our study limitations, no radiographic evidence of loosening was found. Cementing distal femur prosthesis with a tight canal fit and with a thin and inconsistent cement mantle appears to be a viable option at short and medium term.
  相似文献   

3.

Introduction

The SOFCOT symposium (2005) on periprosthetic fractures of the femur (PFFs) highlighted a high rate of dislocation (15.6% at 6 months) after change of prosthesis. So far, no study has ever proved the benefit of dual-mobility articulation during PFFs revisions. We conducted a comparative study on two prospective cohorts in order to (1) assess the influence of systematic acetabular revision in favor of a double mobility on dislocation rate (2) and in order to evaluate the rate of morbidity associated with this extra surgical procedure.

Hypothesis

A systematic replacement of the cup in favor of a dual-mobility articulation enables to reduce the dislocation rate in PFFs revisions without increasing morbidity.

Methodology

We compared two prospective multicenter cohorts over a year (2005 and 2015) using the same methodology. Any fracture around hip prosthesis which occurred 3 months at least after surgery was included. Data collection was clinical and radiological on preoperative, intraoperative and 6 months after surgery. The 2015 “bipolar” group (n = 24) included patients who had a bipolar revision (both femoral and dual-mobility articulation). The 2005 “unipolar” group (n = 25) included patients who had only a femoral implant revision. Patients were comparable by age (p = 0.36), sex (p = 0.91), ASA score (p = 0.36), history of prosthetic revision (p = 1.00), Katz score (p = 0.50) and the type of fracture according to the Vancouver classification (p = 0.55).

Results

There was a 4% rate of dislocation in the “bipolar group” while there was 21% rate of dislocation in the “unipolar group” (8% of recurrent dislocation) (p = 0.19). The rate of all-cause complications 6 months after surgery was not significantly different (p = 0.07): 12.5% in the 2015 “bipolar” cohort (one dislocation, one non-symptomatic cup migration and one pseudarthrosis of the major trochanter) versus 35% in the “unipolar” cohort (5 dislocations, 1 major trochanter fracture and 1 femur pseudarthrosis, 1 secondary displacement associated with a superficial infection). The surgical revision after 6 months was not significantly different (1/23 or 4% vs. 4/25 or 16%, p = 0.35).

Conclusion

We confirm the low rate of dislocations after fitting a dual-mobility cup in case of revision of the femoral side in case of periprosthetic femoral fracture, as well as the need for additional cases to be carried out upon further studies to significantly confirm the interest of preventing instability after femoral revision.
  相似文献   

4.

Purpose

Modular cementless elastic acetabular systems have advantages over cemented and hard shell cementless acetabular systems. There are few reports on the medium-term and long-term follow up of this particular type of implant. This study describes our experience with the Atlas IIIp modular acetabular system, which is a thin shell cementless elastic acetabular implant for total hip replacement commercialized under this name in many countries.

Methods

We prospectively followed 244 patients treated with Atlas IIIp acetabular system between 2001 and 2004. Minimum ten year follow up was available for 148 hips (139 patients) from the original cohort of 263 hips (244 patients). One hundred five patients had died from unrelated causes and were excluded from the results. Post-operative and follow up radiographs of patients were assessed; and Harris hip scores were used as clinical outcome. Revision for any reason was defined as the end point for survivorship analysis.

Results

The mean pre-operative Harris hip score was 48 (S.D. 16) and the average post-operative score was 82 (S.D. 12). The mean follow up in our series was 11.5 years, ranging from ten to 13.5 years. Thirteen hips required further surgery in our cohort; of which ten cases required cup revision. The 13-years cumulative implant survival was 91.2 % and the risk of implant revision was 8.8 % at 13 years in 148 hips (139 patients). Kaplan-Meier analysis showed the implant survival rate of 95.2 % at ten years for revision for any reason and 99.4 % for aseptic loosening.

Conclusions

Our clinical experience with this acetabular cup suggests good long-term survival rates that are similar to other cups on the market. The clinical experience in this study shows long-term survival rates that are consistent, acceptable and good results achieved with a low revision rate.Level of evidence: Therapeutic III; therapeutic study.
  相似文献   

5.
Metabolic bone disease may appear as a complication of obesity surgery. Because an imbalance in the osteoprotegerin and receptor–activator of nuclear factor-κB ligand system may underlie osteoporosis, we aimed to study this system in humans in the metabolic bone disease occurring after obesity surgery. In this study we included sixty women with a mean age of 47 ± 10 years studied 7 ± 2 years after bariatric surgery. The variables studied were bone mineral density, β-isomer of C-terminal telopeptide of type I collagen cross-links (a bone resorption marker), the bone formation markers osteocalcin and N-terminal propeptide of procollagen 1, serum osteoprotegerin and receptor–activator of nuclear factor-κB ligand. Serum osteoprotegerin inversely correlated with the bone remodeling markers osteocalcin, β-isomer of C-terminal telopeptide of type I collagen cross-links and N-terminal propeptide of procollagen 1. The osteoprotegerin and receptor–activator of nuclear factor-κB ligand ratio also correlated inversely with serum parathormone and osteocalcin. Bone mineral density at the lumbar spine was associated with age (β = ?0.235, P = 0.046), percentage of weight loss (β = 0.421, P = 0.001) and osteoprotegerin and receptor–activator of nuclear factor-κB ligand ratio (β = 0.259, P = 0.029) in stepwise multivariate analysis (R 2 = 0.29, F = 7.49, P < 0.001). Bone mineral density at the hip site was associated only with percentage of weight loss (β = 0.464, P < 0.001) in stepwise multivariate regression (R 2 = 0.21, F = 15.1, P < 0.001). These data show that the osteoprotegerin and receptor–activator of nuclear factor-κB ligand system is associated with bone markers and bone mineral density at the lumbar spine after obesity surgery.  相似文献   

6.

Background

The preoperative bone defect and the reconstruction of the center of rotation of the hip are critical in acetabular revision surgery. Uncemented oblong cups are employed in order to manage these issues. We analyzed the clinical results and rates of revision of two different uncemented oblong cups, the reconstruction of the center of rotation of the hip, as well as the rate of radiological loosening and possible risk factors.

Materials and methods

Forty-five patients (46 hips) underwent acetabular revision surgery using two different uncemented oblong cups. We assessed the clinical results and the survival rate for revision and aseptic loosening. Intraoperative bone loss was classified according to Paprosky, and acetabular reconstruction was assessed according to Ranawat. The mean follow-up was 7.2 years (range 4–11 years).

Results

There were four re-revisions (three due to aseptic loosening); the survival rate for re-revision due to aseptic loosening was 60.1 % at seven years. The mean distance between the center of the femoral head prosthesis and the approximate center of the femoral head improved from 21.5 to 10.2 mm. Thirteen cups showed radiological loosening; the survival rate for radiological loosening at seven years was 40.54 %. A smaller postoperative horizontal distance was correlated with cup loosening.

Conclusions

Although optimal acetabular reconstruction can be achieved by using oblong uncemented cups in revision hip surgery, the clinical and radiological results are not encouraging. Excessive medialization of the cup may increase the rate of loosening.  相似文献   

7.

Introduction

The aim of this prospective study was to evaluate load-transfer mechanisms and stress patterns of periacetabular cortical and cancellous bone after cemented total hip arthroplasty (THA) in vivo using computed tomography (CT) assisted osteodensitometry. In addition we analyzed the efficacy of CT in detecting radiolucent lines around the acetabular component compared to plain radiography.

Materials and methods

Twenty-two cemented acetabular cups were investigated using conventional sequential axial CT scans (Ø 8 days and 26 months post-OP) and plain radiography (Ø 5 days and 40 months post-OP). CT assisted osteodensitometry was used to determine cancellous and cortical bone bone density (BD). Radiolucent lines were evaluated using both CT and plain radiography.

Results

Significant BD loss at the time of follow-up was only detectable ventral to the cup (cortical bone: ?16%, P = 0.001; cancellous bone: ?31%, P = 0.001). The BD changes dorsal and cranial to the cup were not significant. Postoperatively no radiolucent lines were observed in the cement-bone interface by CT, while on plain radiography acetabular lucent lines were seen in 12 out of 22 cases.

Conclusion

CT-osteodensitometry has the technical ability to discriminate between cortical and cancellous bone structures with respect to strain-adapted remodeling: sufficient cancellous and cortical bone stock remained dorsal and cranial to the cup indicative of a balanced load transfer to these regions. CT-osteodensitometry has the potential to become an effective instrument for quality control in THA and the method of choice for in vivo determination of periprosthetic BD. In contrast, plain radiography is more suitable for the early detection of radiolucent lines compared to axial CT scans.
  相似文献   

8.

Purpose

Chronic pain and discomfort are common after inguinal hernia repair (IHR). In this study, results from a 3-year follow-up from a randomized controlled study comparing three different mesh repairs for postoperative pain, discomfort, Quality of Life (QoL) and patient satisfaction are reported.

Methods

Between November 1, 2006 and January 31, 2009, 309 men, who underwent day surgery for primary unilateral inguinal hernia under local anesthesia, were randomized to three different mesh repairs; UltraPro Hernia System (U), Prolene Hernia System (P) and Lichtenstein procedure (L).

Results

Preoperatively, there were no differences between groups regarding demographics, symptoms, inguinal pain or QoL (SF-36 and a hernia-specific questionnaire). Operating time, postoperative pain, complications and time to full recovery were similar. At 36 months, 21 patients indicated pain [L, n = 6, P, n = 6 and U, n = 9; VAS (median (IQR)): L 0.4 (0.2–1.7), P 0.2 (0.1–2.3) and U 1.6 (0.7–4.6), p = ns]. Physical QoL was reduced in all groups before surgery and was similarly increased to normal levels after 3 months without further changes throughout the study. Although 92 % of participants were satisfied, sixteen percent reported any discomfort from the groin (ns between groups). Five recurrences were reported (L, n = 2, P, n = 1 and U, n = 2, p = ns).

Conclusions

After 3 years of follow-up, all three procedures provided equally good results regarding, pain, discomfort and QoL and could therefore be recommended for primary IHR in LA.
  相似文献   

9.

Background

Hip reconstructive surgery in cerebral palsy (CP) patients necessitates either femoral varus derotational osteotomy (VDRO) or pelvic osteotomy, or both. The purpose of this study is to review the results of a moderate varisation [planned neck shaft angle (NSA) of 130°] in combination with pelvic osteotomy for a consecutive series of patients.

Methods

Patients with CP who had been treated at our institution for hip dysplasia, subluxation or dislocation with VDRO in combination with pelvic osteotomy between 2005 and 2010 were reviewed.

Results

Forty patients with a mean follow-up of 5.4 years were included. The mean age at the time of operation was 8.9 years. The majority were non-ambulant children [GMFCS I–III: n = 11 (27.5 %); GMFCS IV–V: n = 29 (72.5 %)]. In total, 57 hips were treated with both femoral and pelvic osteotomy. The mean pre-operative NSA angle of 152.3° was reduced to 132.6° post-operatively. Additional adductor tenotomy was performed in nine hips (16 %) at initial operation. Reimers’ migration percentage (MP) was improved from 63.6 % pre-operatively to 2.7 % post-operatively and showed a mean of 9.7 % at the final review. The results were good in 96.5 % (n = 55) with centred, stable hips (MP <33 %), fair in one with a subluxated hip (MP 42 %) and poor in one requiring revision pelvic osteotomy for ventral instability.

Conclusions

This approach maintains good hip abduction and reduces soft-tissue surgery. Moderate varisation in VDRO in combination with pelvic osteotomy leads to good mid-term results with stable, pain-free hips, even in patients with severe spastic quadriplegia.
  相似文献   

10.

Introduction

Successful reconstruction during total hip arthroplasty for acetabular bone defects remains challenging. The purpose of our study was to evaluate clinical and radiographic results and performed a survivorship analysis for patients with acetabular bone loss undergoing total hip arthroplasty (THA) or revision THA using Kerboull-type acetabular reinforcement device(KT plate). Additionally, some independent prognostic factors for radiographic failure were identified.

Methods

A retrospective cohort study was conducted. Thirty patients (36 hips) were available for follow-up examination between 1997 and 2012, with a mean follow-up period of 10 years. We evaluated clinical and radiographic results. The mean patient age at the time of the operation was 66 years.

Results

Failure occurred in 6 cases, and further revisions were required for 2 hips. With failure for any reason as an endpoint, the cumulative survival at 10 years was 85%. Survival analysis at 10 years with failure as the endpoint revealed that the inclination angle of the KT plate ≤ 45° group showed higher survivorship than the inclination angle > 45° group (95.8 vs. 63.6%, P = 0.0047).

Conclusions

With a mean follow-up of 10 years, the clinical and radiographic outcomes were satisfactory. While this study group was small, the results suggest that prosthesis longevity may be improved by setting the inclination angle of this reinforcement device at ≤ 45°.
  相似文献   

11.

Introduction and hypothesis

Female pelvic organ prolapse (POP) is a common condition, with a lifetime risk for surgery of 10–20%. Prolapse procedures are known to have a high reoperation rate. It is assumed that etiological factors for POP may also be risk factors for POP recurrence after surgery. There are few reviews available evaluating risk factors for prolapse and recurrence or recently updated meta-analysis on this topic. Our aim was to perform a systematic review and quantitative meta-analysis to determine risk factors for prolapse recurrence after reconstructive surgery.

Methods

Four electronic databases (MEDLINE, PubMed, EMBASE, and Google Scholar) were searched between 1995 and 1 January 2017, with no language restrictions.

Results

Twenty-five studies met inclusion criteria for a total of 5082 patients with an average recurrence rate of 36%. Variables on which a meta-analysis could be performed were body mass index (BMI) (n = 12), age (n = 11), preoperative stage (n = 9), levator avulsion (n = 8), parity (n = 8), constipation/straining (n = 6), number of compartments involved (n = 4), prior hysterectomy (n = 4), familiy history (n = 3), and several other predictors evaluated in only three studies. The following meta- analyses identified significant predictors: levator avulsion [odds ratio (OR) 2.76, P <?0.01], preoperative stage 3–4 (OR 2.11, P <?0.001), family history (OR 1.84, P = 0.006), and hiatal area (OR 1.06/cm2, P = 0.003).

Conclusions

Levator avulsion, prolapse stage, and family history are significant risk factors for prolapse recurrence.
  相似文献   

12.
A retrospective study was performed to evaluate the cement mantle in two groups of patients treated with the acetabular components of cemented Exeter total hip arthroplasties (THAs). Two groups of 20 patients were compared: Group 1 received non-flanged acetabular cemented cups (Contemporary, Stryker) and Group 2 received flanged acetabular cemented cups (X3 Rim Fit, Stryker). Cups in Group 2 were implanted after using a rim cutter device. Group 2 showed better penetration of cement in zone 1 (10.76 mm compared with 2.93 mm; p = 0.008) and a thicker cement mantle in zone 1 (3.57 mm compared with 2.89 mm; p = 0.04). More cups in Group 2 had a cement mantle thickness less than 3 mm (30 % in Group 1 compared with 70 % in Group 2; p = 0.0039). No other radiological differences were observed. These results favor the use of a rim cutter device and flanged cup to improve the cement mantle for the acetabular components of cemented Exeter THAs. However, the improvements were less than expected. In view of the results of previous studies, further research is therefore needed to assess the value of this approach in improving the acetabular cement mantle.  相似文献   

13.
This study is a 5- to 11-year retrospective followup of 40 hips in 33 patients with cementless acetabular revision for aseptic failure of a cemented total hip arthroplasty. A porous coated, Harris-Galante acetabular component was used in all revisions. Thirty-eight of the 40 hips received acetabular bone grafting at revision. The mean Harris Hip Score improved from 51 points just before the index cementless revision to 87 points at the most recent followup. Twenty-nine of 40 (73%) hips were classified as having a good or excellent result. Radiolucencies were observed in seven of the 40 (18%) hips at the most recent followup, but none of these radiolucencies were complete or progressive. Five of the 40 (13%) hips were rated as failures and required repeat revision. Two (5%) of these failures were caused by aseptic loosening, with both hips having severe acetabular bone damage at the time of the index revision. This failure rate for aseptic loosening was less than that reported for cemented acetabular revision, thereby confirming the efficacy of cementless acetabular components in revision hip surgery in the intermediate term.  相似文献   

14.

Purpose

Modular acetabular reconstructive cups have been introduced in an attempt to offer initial rigid fixation by iliac lag screws and ischial pegs, to support bone grafts with a flanged metal socket, and to restore original hip center in acetabular revision. The purpose of this study was to clarify minimum ten year follow-up results of this cup system with morsellised allografts in revision cases.

Methods

We retrospectively investigated 54 acetabular revisions at a mean of 11 years (range, ten to 14 years). The indications were Paprosky’s type 2B (eight hip), 2C (eight hips), 3A (23 hips), 3B (nine hips), and 4 (six hips).

Results

Using aseptic loosening as the endpoints, the survival rate was 89.3 % (95 % CI 81–98). Radiographically, one type 3A hip, three type 3B hips and one type 4 hip showed aseptic loosening while no type 2 hips or no cemented cups showed loosening.

Conclusions

The modular reconstructive cups for acetabular revision showed bone stock restoration and stable implantation.  相似文献   

15.

Background

Proximal humeral bone loss in shoulder arthroplasty is a complex problem with a heterogeneous presentation. Different etiologies may contribute to varying degrees of severity in bone loss that dictate different treatment approaches.

Objectives

The purpose of this is article is to describe our technique for treatment of proximal humeral bone loss with proximal humeral allograft prosthetic composites (APC) and identify factors that may predict when larger allografts may be necessary.

Materials and methods

Ninety-nine patients were identified that had undergone reverse total shoulder arthroplasty with use of a proximal humeral allograft. Thirty-nine of these had large allografts that involved a significant portion of the diaphysis. Preoperative characteristics were examined to identify factors that may be associated with use of a larger diaphyseal-incorporating allograft.

Results

Well-fixed humeral stems could be treated with short metaphyseal allografts in 55 of 65 (85%) cases. Loose stems required longer diaphyseal-incorporating allografts in 28 of 31 (90%) cases, and these were commonly associated with periprosthetic fractures (n = 10), failed prior APC (n = 6), and infection (n = 5). Noncemented stems required diaphyseal grafts in 75% of cases, compared to cemented stems which required larger grafts in 34% of cases.

Conclusions

Proximal humeral bone loss in the setting of revision shoulder arthroplasty can be successfully managed with a reverse total shoulder and proximal humeral allograft. Larger allografts are frequently required for loose humeral stems, and noncemented stems appear more likely to require larger allografts than cemented stems.
  相似文献   

16.

Background

Intestinal ostomies are common surgical procedures performed in visceral surgery as part of management for several gastrointestinal diseases. This study aims to report the socio-demographic characteristics, indications and prognosis of intestinal ostomies in low-income country.

Methods

This was a 4-year retrospective study (January 2013 to December 2016) at Zinder National Hospital (Niger). All patients with a digestive ostomy on an ileum or colic segment were included in the study.

Results

During the study period, 2437 patients underwent digestive surgery, including 328 gastrointestinal stomas (13.5%). Patients classified ASA3 were 60.7% (n = 199). The median age was 12 years (IQ: 7–25). Children represent 64% (n = 210) of patients with ostomy. The sex ratio was 2.60. The stoma was performed in emergency in 96.3% (n = 316) of cases. Acute peritonitis was the main indication of the stoma in 70.73% (n = 232). The ileostomies accounted for 75.61% (n = 248). Ostomy was intended as temporary in 97.3% of cases (n = 319). Complications were observed in 188 patients (57.3%). Mortality was 14.02% (n = 46). The indigent status (OR: 4.15 [2.20–7.83], P = 000), ASA score 4 (OR: 2.53 [1.54–4.15], P = 0.0003), Altemeier class IV (OR: 4.03 [2.10–7.73], P = 0.0000) and ileostomy (OR: 2.7853 [1.47–5.29], P = 0.0018) were statistically associated with the occurrence of major complications. The mean time for stoma closure was 59.3 ± 14.5 days.

Conclusion

Acute peritonitis was the main indication of digestive ostomy. The occurrence of major complications was associated with bad socioeconomic status, ASA4 score, Altemeier class IV and ileostomy.
  相似文献   

17.

Objective

A number of case reports have demonstrated FDG uptake around mesh prostheses after hernia repair surgery. This study characterizes FDG PET-CT findings after hernia repair with synthetic mesh in a series of cancer patients.

Materials and methods

FDG PET-CT studies were reviewed for increased FDG uptake consistent with CT appearances of post-surgical hernia repair in cancer patients. The findings were correlated with clinical data and follow-up studies.

Results

53 PET-CT studies in 22 patients (18 males, 31–79 years) were identified. Surgery for repair of inguinal (n = 14), ventral (n = 5) or umbilical (n = 3) hernia was performed, 4–204 months prior to PET-CT. FDG avidity was focal or linear in the region of the anterior abdominal or pelvic wall (mean SUV max 4.0 ± 2.3). Corresponding nonspecific CT findings included soft tissue thickening (n = 18), fat infiltration (n = 20) and fluid collection (n = 19) in the region of the omentum, adjacent to or in the inner abdominal or pelvic wall at the surgical site. Linear hyper-dense structures (n = 9) or metallic clips (n = 8) seen on CT suggested benign postoperative changes. In 10/12 (83.3%) patients with repeat PET-CT, FDG uptake remained unchanged, one showed more diffuse uptake and another showed reduced uptake on follow-up. There was neither significant change in CT appearance at the surgical site in these 12 patients, nor in 3 additional patients with only CT follow-up. Another 3 patients had previous CT demonstrating hernia at the same location.

Conclusion

With increasing use of synthetic mesh, awareness of variations in FDG PET-CT appearance is important to avoid false interpretation in cancer patients.
  相似文献   

18.

Purpose

Patients suffering from post traumatic osteoarthritis of the acetabulum often require a total hip arthroplasty at a relatively young age. Long-term data outcome studies for this population are lacking. We report on the long-term outcome of 20 acetabular fractures in 20 patients treated with impaction bone grafting and a cemented cup after a mean follow-up of 18 years (range, 12–26 years).

Methods

The group consisted of 14 males (70 %) and six females (30 %) with an average age of 53.3 years (range, 35–75 years) at time of surgery. No patients were lost to follow-up. Four patients died and three patients underwent a revision; at review 13 patients were still living with their implant in situ. Survivorship analysis was performed at 20 years follow-up for three endpoints.

Results

Survival rate with endpoint revision for any reason at 20 years postoperative was 74.7 % (95 % confidence interval (CI), 40–91 %), 80.0 % (95 % CI, 41–95 %) for endpoint aseptic loosening, and 63.9 % (95 % CI 32–84 %) for endpoint radiographic failure. Three acetabular components were revised at 14.5, 15.3, and 16.7 years postoperative. Two cups failed for aseptic loosening and one cup failed due to septic loosening. The average postoperative Harris hip score was 82 (range, 56–100).

Conclusion

Acetabular reconstruction with impaction bone grafting and the use of a cemented cup after acetabular fracture is an attractive technique with acceptable long-term results and a low complication and re-operation rate.  相似文献   

19.

Purpose

Severe scoliosis is primarily managed with surgery. This cohort study describes the incidence of surgically treated scoliosis among Swedish youth and young adults, stratified by age, sex, scoliosis type, and surgical approach and identifies changes in incidence rate and hospital length of stay (LOS), infections requiring re-surgery and mortality within 90 days.

Methods

Swedish youth, 0–21 years, (n = 3062) with a diagnostic code for scoliosis and spine surgery between 2000 and 2013 were selected from the National Patient Register. Incidence was computed by comparing individuals with surgically treated scoliosis to the total at risk population. Linear regression models and Spearman correlation coefficients analyzed trends over time.

Results

Overall annual incidence per 100,000 individuals was 9.1 (5.9 males/12.5 females). Annual incidence increased over 14 years from 5.1 to 9.8; an average 4.6% per year (p < 0.001). Adolescent idiopathic scoliosis was most common (4.5 per 100,000; n = 1516) followed by neuromuscular 2.7 (n = 913) and congenital 0.7 (n = 236). Average LOS decreased among scoliosis types except infantile and neuromuscular scoliosis. Posterior fusion was the most common surgical approach (75%) followed by anterior (18%) and anteroposterior fusion (7%). Posterior fusions significantly increased with a resultant decrease in anterior and anteroposterior fusion over time. Individuals with neuromuscular scoliosis exhibited the highest mortality (n = 12; 1.3%) and (n = 59; 6%) of individuals with neuromuscular scoliosis and (n = 12; 15%) with scoliosis related to MMC required revision surgery due to post-op infection.

Conclusions

Surgical management of scoliosis is increasing with a concurrent decrease in hospital LOS. Surgical management of neuromuscular scoliosis is associated with high 90-day post-operative infections and mortality rate.
  相似文献   

20.

Introduction

Some patients require one or more reoperative interventions after undergoing primary antireflux surgery (ARS). We compared outcomes after primary and reoperative ARS.

Methods

We queried a prospectively maintained database to identify patients who underwent ARS from September 23, 2003 to May 28, 2016. Patients were categorized into four groups: A (primary ARS), B (first reoperative ARS), C (second reoperative ARS), or D (≥ third reoperative ARS). Patients completed follow-up foregut symptom surveys and satisfaction questionnaires at regular intervals.

Results

In total, 940 patients were studied (A: n = 545, B: n = 302, C: n = 80, D: n = 13). Age, sex, and BMI were comparable across groups. Heartburn was the most common preoperative symptom in A, whereas dysphagia was more common in B–D. Open approach, mean operative time, and mean blood loss increased from A to D (P < 0.05), as did need for Roux-en-Y reconstruction. Vagal injury (2–19–33–54%; P < 0.05), visceral perforation (2–20–36–23%; P < 0.05), postoperative leak (0.2–2–6–8%; P < 0.05 A vs. all), and morbidity (2–10–14–39%; P < 0.05) also increased from A to D. At mean follow-up of 36 months, the proportion of patients who reported no significant symptoms, excellent satisfaction, and likeliness to recommend this surgery to a friend progressively declined with each successive reintervention (P < 0.05).

Conclusions

Complications and patient-reported outcomes worsen with each reoperative ARS.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏