首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Since 1979, 50 children, 4 months to 15 years of age, have successfully undergone cardiac valve replacement with the St. Jude Medical prosthesis (St. Jude Medical, Inc., St. Paul, Minn.). There were 24 boys and 26 girls. The valve replaced was mitral in 28 children, aortic in 15, mitral and aortic in 1, and mitral and tricuspid in 1. A left-sided tricuspid valve was replaced in 3 children. Anticoagulant therapy was maintained in all children; 40 children were treated with warfarin, whereas 10 children who underwent aortic or mitral valve replacement were on a regimen of aspirin combined with dipyridamole. The follow-up period, comprising 224 patient-years, ranged from 1 to 10 years. There were four valve-related complications: one from thromboembolism, two from valve thrombosis, and the other one from prosthetic valve endocarditis. Actuarial rate free from all valve-related complications at 10 years was 84.7%. There were four late deaths: one from valve thrombosis and the others from non-valve-related complications. Actuarial survival rate at 10 years was 90.8%. All surviving children are in functional class I, and no child so far has needed replacement of a prosthesis because of somatic growth. These results indicate that the St. Jude Medical prosthesis is a cardiac valve substitute of choice for valve replacement in children.  相似文献   

2.
During the 10-year period between 1980 and December 1989, isolated mitral valve replacement (MVR) with the St. Jude Medical (SJM) valve prosthesis was performed on 404 patients at our hospital, and a long-term postoperative follow-up was conducted. There were 161 males and 243 females ranged in age from 1 year to 73 years. Early operative mortality was 5.2%. Follow-up period for 383 patients who discharged from the hospital was 1970.7 patient-years. Twenty of these patients died during the follow-up period, and a late mortality rate was 5.2%. During 10 years, thromboembolic event occurred in 8 patients. Four patients had anticoagulant-related bleeding, 4 had paravalvular leak, and 5 underwent re-operations. There was neither structural valve failure nor prosthetic valve endocarditis. Therefore, the actuarial survival rate and the valve-related death-free rate at 10 years were 83.2%, and 96.8%. Of the patients who survived, New York Heart Association class improved significantly (93% in classes II and III preoperatively and 71% in class I postoperatively). Linearized rates for thromboembolism, anticoagulant-related bleeding, and hemolysis were 0.41%, 0.20% and 0.36%/100 patient-years, respectively. The actuarial estimate of incidence free from all complications was 92.0% at 10 years. On the basis of this 10 years' experience, we believe that the SJM valve prosthesis is an excellent mechanical prosthesis for mitral valve replacement, in terms of hemodynamic performance and low thrombogenicity in patients receiving anticoagulants.  相似文献   

3.
A study was conducted on 20 patients who underwent tricuspid valve replacement (TVR) with the St. Jude Medical (SJM) valve. Isolated TVR was performed on 9 patients, and additional mitral, or mitral and aortic valve replacements were performed on 11 patients. Four patients (20%) died in the early postoperative period, but there were no deaths related to the SJM valve in the tricuspid position. The mean follow-up period of the 16 survivors was 74.4 months, and there have been no deaths during the follow-up period. The postoperative actuarial survival rate was 80%, 10 years after surgery. Three patients, representing 0.25%/patient-months, developed valve thrombosis, the valve thrombosis-free rate being 72.8%, 10 years after surgery, while entrapment of a leaflet by endothelial pannus was found in one patient, representing 0.08%/patient-months. Thus, the incidence of all prosthetic valve-related complications was 0.34%/patient-months, and the postoperative complication-free rate was 65.3%, 10 years after surgery. The medium-term follow-up study of TVR with the SJM valve revealed no prosthetic valve-related deaths and a relatively low incidence of prosthetic valve-related complications. However, as with other mechanical valves, valve thrombosis was a major risk posed by the SJM valve in the tricuspid position.  相似文献   

4.
St. Jude Medical valve replacement was performed in 1,039 patients; 320 had aortic (AVR), 543 mitral (MVR), and 176 had double valve replacement (DVR). There were 44(4.2%) early deaths. Follow-up extended in 995 patients from 10 to 130 months, with a cumulative period of 2,730 patients-years. The overall survival rates of AVR, MVR, and DVR patients at 10 years were 60.5%, 89.6%, 90.3% respectively. The linearized incidences of valve thrombosis, thromboembolism, anticoagulation-related hemorrhage, prosthetic valve endocarditis, and significant hemolysis were as follows: 0.11%/pt-yr, 1.33%/pt-yr, 0.04%/pt-yr, 0.18%/pt-yr, and 0.11%/pt-yr, respectively. There were no structural failure after 10 years follow-up. Reoperation (explant and re-replacement or suture repair) was required in 10 patients. Seven of them had periprosthetic leakage, 2 had valve thrombosis, and one underwent reoperation because of a technical error. Actuarially over 98% of patients were free of valve-related mortality at 10 years. St. Jude Medical valve is an excellent alternative for use in the surgical treatment of valvular heart disease.  相似文献   

5.
OBJECTIVE: The choice of the valve substitute in the tricuspid position remains controversial. A St. Jude Medical valve is a choice of valve substitute and its lower thrombogenicity and excellent hemodynamic performance have been reported even in the tricuspid position. However, little is known of the long-term durability of the St. Jude Medical valve in the tricuspid position. Our long-term experience of tricuspid valve replacement showed the higher thrombogenicity than we had expected, therefore, this study was done to reconsider our strategy for valve choice. METHODS: This study reviewed 23 patient who underwent 25 tricuspid valve replacements with the St. Jude Medical valves from 1980 to 1997. The mean age was 40 years. Eleven patients (48%) were men. There were four in-hospital deaths (17%). The remaining 19 patients were all alive and followed from 2.2 to 19.0 years (mean 11.8 years). RESULTS: The overall survival, including hospital mortality, was 83%, 10 and 15 years after surgery. Valve thrombosis occurred in six patients. Freedom from valve thrombosis was 78 and 70%, 10 and 15 years after surgery, respectively. The linearized rate of the valve thrombosis was 2.9%/patient-years. Six patients required reoperation. The mean interval to reoperation was 9.5 years. Freedom from reoperation was 83% and 75%, 10 and 15 years after surgery, respectively. The linearized rate of the reoperation was 2.8%/patient-years. No structural valve deterioration was found. Echocardiographic study showed that the function of the St. Jude Medical valve without valve-related complications was well maintained. CONCLUSIONS: The higher thrombogenicity of the St. Jude Medical valve in the tricuspid position altered our choice of valve substitutes from the St. Jude Medical valve to a bioprosthesis which is lack of need for anticoagulant therapy except for juvenile patients who are able to maintain potent anticoagulant therapy.  相似文献   

6.
BACKGROUND: All patients undergoing St. Jude Medical valve replacement at the Medical University of South Carolina since January 1979 have been followed prospectively at 12-month intervals. METHODS: This report describes long-term experience in 710 adult patients undergoing isolated aortic (AVR) (418) or mitral valve replacements (MVR) (292) with this prosthesis from January 1979 to December 1996. RESULTS: Ages ranged from 19 to 84 years (54.8 +/- 15.1 AVR, 51.8 +/- 12.9 MVR; mean +/- SD). Male gender predominated in the AVR group (70%) and female gender in the MVR group (62%). One hundred and fifty-seven patients (22%) had associated coronary artery bypass grafting (AVR 27%, MVR 15%). Thirty-day operative mortality was 5.3% (22/418) in the AVR group and 5.1% (15/292) in the MVR group. Follow-up is 96.9% complete and ranges from 1 month to 16.9 years (AVR, 2,376 patient-years, mean 5.7 +/- 4.5 years; MVR, 1,868 patient-years, mean 6.4 +/- 4.8 years). In the AVR group, 120 late deaths have occurred and actuarial survival was 78.0 +/- 2.3%, 58.0 +/- 3.2%, and 36.8 +/- 4.8%; at 5, 10, and 15 years, respectively. Forty-six patients have sustained 55 thromboembolic (TE) events (2.3%/patient-year). Fifty-one patients had anticoagulant-related bleeding complications (2.7%/patient-year). The mean improvement in New York Heart Association (NYHA) functional class from preoperative to postoperative was 3.0 +/- 0.8 to 1.7 +/- 0.1 (p < 0.05). In the MVR group, there have been 84 late deaths, and the actuarial survival was 79.3 +/- 2.5%, 60.1 +/- 3.5%, and 49.3 +/- 4.1% at 5, 10, and 15 years, respectively. Fifty-two patients have had 64 TE events (3.5%/patient-year). Twenty-three patients had anticoagulant-related bleeding complications (1.6%/patient-year). The mean improvement in NYHA functional class was from 3.3 +/- 0.6 to 1.8 +/- 0.1. There were no mechanical failures in either group. CONCLUSIONS: With a follow-up now extending to 17 years, the St. Jude Medical valve continues to be a reliable mechanical prosthesis with low and stable rates of valve-related complications.  相似文献   

7.
Ten years' experience with the St. Jude Medical valve prosthesis   总被引:3,自引:0,他引:3  
Records of 1,298 consecutive patients who had received the St. Jude Medical prosthesis were reviewed (713 male and 585 female patients; mean age, 61.79 +/- 13.4 years). Early mortality was 5.7% (74 patients). Ninety-three percent complete follow-up was accomplished for the 1,224 patients who left the hospital (4,306.50 patient-years). One hundred ninety-two of these patients died, a late mortality of 16.9%. Sixty-four patients experienced thromboembolic episodes (17 major and 35 permanent). Twenty-four patients had anticoagulant-related bleeding, 4 had valve thrombosis, 7 had prosthetic valve endocarditis, 9 had paravalvular leak, and 10 underwent reoperation. There was no structural valve failure in this series. Twenty-two of the 118 patients who had valve-related complications died; another 15 patients died of sudden and unknown causes. Therefore, the total number of valve-related deaths was 37. Of those patients who survived, New York Heart Association functional class improved significantly (98% in classes II and III preoperatively and 96% in classes I and II postoperatively). Linearized rates for thromboembolism, valve thrombosis, and anticoagulant-related bleeding were 1.49% +/- 0.19%, 0.09% +/- 0.05%, and 0.56% +/- 0.11%/100 patient-years, respectively. The actuarial estimate of incidence free from all complications, operative death, and valve-related death was 66.9% +/- 8.2% at the end of 9 years. In spite of old age and advanced heart disease, the patients who received the St. Jude Medical prosthesis had very good results over a 10-year period.  相似文献   

8.
9.
From April 1, 1979 to August 31, 1983, 228 patients underwent isolated aortic (AVR) (118) or mitral (MVR) (90) valve replacements with a new tilting disc valve prosthesis, the St. Jude prosthesis, at the Medical University of South Carolina. Age ranged from 6 to 84 years (mean 49.1 +/- 19.2 AVR, 44.5 +/- 16.5 MVR). Male sex predominated in the AVR group (68%) and female sex in the MVR group (68%). Thirty-five patients (16.8%) had associated coronary bypass surgery (AVR 23.7%, MVR 7.8%). There were seven deaths (3.4%) occurring during the same hospitalization (AVR: 3/118, 2.5%; MVR: 4/90, 4.4%). Follow-up is 97.6% complete and ranges from 1 to 54 months (mean 19.6 +/- 12.4). In the AVR group, nine late deaths have occurred and actuarial survival at 42 months is 86.7 +/- 3.8%. Three patients have sustained thromboembolic episodes for a linearized rate of 1.6% patient-year, and the probability of remaining free of thromboembolism at 42 months is 96.9 +/- 1.8%. The mean improvement in functional class from preoperative to postoperative is 3.1 +/- 0.7 to 1.2 +/- 0.4 (p less than 0.001). In the MVR group, there have been four late deaths, and the actuarial survival at 42 months is 89.3 +/- 3.8%. Two patients have sustained thromboembolic complications for a linearized rate of 1.2%/patient-year, and the probability of remaining free of thromboembolism at 42 months is 97.2 +/- 2%. The mean improvement in functional class from before to after surgery is 3.2 +/- 0.7 to 1.3 +/- 0.5 (p less than 0.001). There have been no thromboses of the St. Jude valve in the mitral or aortic position, no mechanical failures, and no patient has had significant valve-related hemolysis. Because of this experience, the St. Jude Medical heart valve prosthesis is our prosthesis of choice for any patient undergoing valve replacement with a mechanical prosthesis.  相似文献   

10.
Twenty-year experience with the St Jude Medical mechanical valve prosthesis   总被引:2,自引:0,他引:2  
BACKGROUND: We have prospectively followed all adult St Jude Medical mechanical valve recipients at the Medical University of South Carolina since the initial implant in January 1979 and now present our 20-year experience. METHODS: We prospectively followed 837 valve recipients (aortic valve replacement; n = 478; mitral valve replacement; n = 359) from January 1979 to December 2000 at 12-month intervals. RESULTS: Ages ranged from 19 to 84 years. Follow-up averaged (mean +/- standard deviation) 7 +/- 5 years (98% complete). Patients were in New York Heart Association class III or IV in 77% (aortic valve replacement) and 89% (mitral valve replacement) preoperatively. A 19-mm valve was implanted in 15.5% of aortic valve replacement patients. Coronary bypass was required in 31% of aortic valve replacements and 20% of mitral valve replacements. Operative mortality was 17/478 (3.6%) in aortic valve replacement and 19/359 (5.3%) in mitral valve replacement, and multivariable predictors were 19-mm valve size, 3 or more coronary bypass grafts, and New York Heart Association class IV for aortic valve replacement and New York Heart Association class IV and age for mitral valve replacement. Actuarial survivorship at 10 and 20 years was 57% +/- 3% and 26% +/- 5% for aortic valve replacement and 61% +/- 3% and 39% +/- 4% for mitral valve replacement. Multivariable predictors of late death were African-American ethnicity, New York Heart Association class III or IV, coronary bypass, and age for aortic valve replacement and New York Heart Association class III or IV, coronary bypass, and age for mitral valve replacement. For aortic valve replacement, effective orifice area was univariately (P =.002) but not multivariately (P =.378) predictive of late death. Structural valve deterioration was not observed. For aortic valve replacement, actuarial freedom (at 10 and 20 years) from reoperation was 93% +/- 1% and 90% +/- 2%; thromboembolism, 82% +/- 3% and 68% +/- 8%; bleeding events, 77% +/- 3% and 66% +/- 6%; prosthetic valve endocarditis, 94% +/- 1% and 94% +/- 1%; valve-related mortality, 94% +/- 2% and 86% +/- 4%; and valve-related mortality or morbidity, 58% +/- 3% and 32% +/- 8%. For mitral valve replacement, actuarial freedom (at 10 and 20 years) from reoperation was 96% +/- 1% and 90% +/- 3%; thromboembolism, 77% +/- 3% and 59% +/- 7%; bleeding events, 86% +/- 2% and 65% +/- 8%; prosthetic valve endocarditis, 98% +/- 1% and 96% +/- 2%; valve-related mortality, 89% +/- 0.2% and 74% +/- 8%; and valve-related mortality or morbidity, 63% +/- 3% and 29% +/- 7%. CONCLUSIONS: After 2 decades of observation with close follow-up, the St Jude Medical mechanical valve continues to be a reliable prosthesis.  相似文献   

11.
Since 1974, 14 patients underwent tricuspid valve replacement (TVR) with prosthetic heart valves. Hardy's operation was undergone in 2 patients with Ebstein's anomaly and mitral valve surgery or multiple valve surgery were undergone in 9 patients with rheumatic valvular disease, concomitantly. Four types of prosthetic heart valves were used in the tricuspid position, i.e. 2 Starr-Edwards prostheses, 1 Hancock xenograft, 1 Bj?rk-Shiley prosthesis and 12 st. Jude Medical prostheses. The operative mortality rate was 14.3% (2/14) and 2 hospital deaths were due to low cardiac output syndrome. Twelve survivors have been followed with a maximum follow-up of 13 years and the mean of 4.7 years. There were 3 late deaths due to congestive heart failure and prosthetic valve endocarditis (PVE) of the aortic Bj?rk-Shiley prosthesis. There was 1 PVE of the tricuspid Starr-Edwards prosthesis and 1 thrombosis of the tricuspid Bj?rk-Shiley prosthesis, but no thrombosis and no other valve-related complications of SJM prostheses in the tricuspid position. The post-operative NYHA function class improved satisfactorily in 9 survivors. Judging from our relatively satisfactory post-operative results in TVR cases using SJM prostheses, SJM prosthesis in the tricuspid position is one of advisable prosthesis to get satisfactory hemodynamic improvement post-operatively.  相似文献   

12.
13.
14.
15.
16.
17.
BACKGROUND: We have used the Starr-Edwards ball (S-E) valve since 1963, the St. Jude Medical (SJM) valve since 1978, and the ATS valve, since 1993 as the first choice of mechanical valve. In this study, the results with each valve during the 40 years were investigated in single mitral valve replacement (MVR) cases. PATIENTS AND METHODS: The mean age for S-E valves was 32.8+/-11.1 years old (y.o.), for SJM it was 47.2+/-12.6 y.o. and for ATS it was 56.3+/-11.4 y.o., indicating the aging of patients over time. The operative mortality decreased over the same time from 10.3% to 5.2% then 1.4% respectively. A significant difference was observed among the 3 groups with regards to the valve-related complication-free rate and cardiac event-free rate. However, there was no significant difference among the 3 groups with the other complications. CONCLUSION: Although there are many cases of valve-related complications with S-E valves, they have a role as an initial stage mechanical valve. In view of the long-term results extending over 20 years, the SJM valves is considered as the most reliable valve. The ATS valve is expected to achieve favorable results in the future because it may improve the quality of life (QOL) of patients and produce fewer valve-related complications.  相似文献   

18.
Long term results were compared in 81 operative survivors with MVR using Hancock valve (Hancock group) and 83 using St. Jude Medical valve (SJM group). The cumulative follow-up was 709.0 patients-year (p-y) and 175.2 p-y in the Hancock and SJM groups. Twenty-four percent of the patients in the Hancock group was permanently anticoagulated, while 100% of patients in the SJM group anticoagulated. The 7-year actuarial survival rate including early mortality was 79.3 +/- 4.6% for the Hancock and 93.9 +/- 3.0% for the SJM group (p less than 0.01). The survival rate was significantly higher in the SJM group than that in the Hancock group. The 7-year actuarial event free rate of the valve-related complications in the Hancock and SJM groups were as follows; thromboembolism 88.6 +/- 3.8% vs 95.0 +/- 2.8% (NS), hemorrhage, 94.0 +/- 3.0% vs 98.7 +/- 1.8% (NS), paravalvular leak 92.6 +/- 3.2% vs 97.4 +/- 1.8% (NS), infection 93.9 +/- 3.0% vs 100% (p less than 0.05), valve malfunction 78.0 +/- 5.2% vs 100% (p less than 0.001), overall valve related complications 58.9 +/- 5.9% vs 91.1 +/- 3.5% (p less than 0.001), reoperation for valve-related complication 83.1 +/- 4.6% vs 100% (p less than 0.01). The event free rate of reoperation for valve related complication in the Hancock group was significantly lower than that in the SJM group. The Hancock valve had the acceptable antithrombogenicity, but had the limited long-term durability.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

19.
BACKGROUND: Few reports exist on the results of bileaflet mechanical valve (St. Jude Medical prosthesis; St. Jude Medical, Inc, St. Paul, MN) replacement in long-term dialysis patients. METHODS AND RESULTS: We retrospectively reviewed 12 patients, ranging in age from 50 to 86, undergoing long-term renal dialysis who had also undergone mechanical valve replacement at our institution. Operative procedures included aortic valve replacement, aortic and mitral valve replacement, aortic valve replacement and mitral annuloplasty, mitral valve replacement, and modified Bentall's operation. There was 1 hospital death (8.3%). During the mean follow-up period of 37.1 months (range: 5-87 months), there were 2 noncardiac late deaths. Bleeding from the esophageal varix and from a duodenal ulcer occurred in 1 patient with end-stage liver cirrhosis. There were no other major cases of bleeding or cerebrovascular accidents. There were no valve-related complications. All the survivors demonstrated excellent clinical improvement under the NYHA functional classification. CONCLUSIONS: Our study demonstrated good early and long-term results of mechanical valve replacement in patients undergoing long-term dialysis. These favorable results support the continued use of mechanical valves in dialysis patients.  相似文献   

20.
St. Jude Medical bileaflet valve replacement was performed on 182 patients--aortic in 90, mitral in 70, both sites in 20 and tricuspid in two. The 30-day mortality was 4.3%, and was related to poor preoperative condition (NYHA class III or IV). The late mortality during observation up to 8 years was 9.3%, with actuarial survival 87.4% at 5 years and 86.3% at 8 years. For aortic, mitral and double valve replacement the respective 8-year figures were 88, 87.3 and 76.2%. Late death was associated with high preoperative pulmonary vascular resistance in five cases, dysrhythmia in four, myocardial infarction in two, thromboembolism, paravalvular leakage, prosthetic endocarditis or bleeding, each in one case, and was accidental in two cases. Calculated per 100 patient years the incidence of late thromboembolic events was 1.0, of bleeding complications 0.9 and of prosthetic valve endocarditis and paravalvular leak 0.26 (8, 7, 2 and 2 cases). The NYHA class in the 144 cases available for follow-up was I in 63%, II in 27% and III in 10%. The St. Jude Medical prosthesis thus was reliable, with good long-term performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号