Background

The purpose of the study was to evaluate the implant positions and clinical results of revision total hip arthroplasty (THA) using an imageless navigation with the concept of combined anteversion.

Methods

A total of 40 cementless revision THAs (24 men and 16 women) using an imageless navigation with the concept of combined anteversion were retrospectively evaluated. The concept of combined anteversion was applied in cup positioning based on Widmer's equation (cup anteversion + 0.7 × stem anteversion). The mean follow-up period was 80.7 months. Postoperatively, the inclination of the cup was evaluated on standard anteroposterior view of the radiograph, and the anteversion of the cup and femoral stem was evaluated using computed tomography scan. A cup inclination of 40° ± 10° and combined anteversion of the cup and femoral stem of 37° ± 10° based on Widmer's equation were regarded as the “safe zone.”

Results

The average anteversion of the revised femoral stems was 15.3° ± 2.9° (range, 9.5°-21.5°), whereas that of the remained femoral stems was 17.4° ± 9.7° (range, 4.2°-29.8°). The inclination, anteversion of the cup, and combined anteversion after revision THA were 42.3° ± 3.1° (range, 32.1°-48.2°), 25.0° ± 2.9° (range, 16.9°-29.5°), and 36.1° ± 3.4° (range, 27.2°-42.9°), respectively. Therefore, the position of the implants, relative to the safe zone, showed no outliers after the revision surgery. Neither dislocation nor osteolysis was observed after the surgery.

Conclusion

Favorable results of this study indicate that imageless navigation helps the surgeon in placing the components of revision THA in the safe zone. This study also shows that when this safe zone is consistently obtained, then no postoperative dislocations were observed in these patients over the 6-year follow-up period.  相似文献   

2.
《The Journal of arthroplasty》2023,38(8):1621-1627
BackgroundIliopsoas tendinopathy (IPT) can cause persistent groin pain and lead to dissatisfaction after total hip arthroplasty (THA). This study aimed to report the characteristics, incidences, risk factors, and treatment outcomes of IPT after THA.MethodsWe reviewed primary THAs performed at a single institution between January 2012 and May 2018. Clinical and radiographic analyses were performed on 1,602 THAs (1,370 patients). Patient characteristics, component sizes, inclination and anteversion angles, and antero-inferior cup prominence (≥8 millimeters (mm)), were compared between the groups with and without IPT. Changes in teardrop to lesser trochanter distance were measured to estimate changes in leg length and horizontal offset caused by THA. Logistic regression models were used to identify the risk factors for IPT. IPT was identified in 53 hips (3.3%).ResultsPatients with IPT had greater leg lengthening (12.3 versus 9.3 mm; P = .001) and higher prevalence of antero-inferior cup prominence (5.7 versus 0.4%; P = .002). There was no significant difference in inclination, anteversion, and horizontal offset change between the two groups. In multivariate analyses, greater leg lengthening, prominent acetabular cup, women, and higher body mass index were associated with IPT. All patients reported improvement in groin pain after arthroscopic tenotomy, while 35.7% with nonoperative management reported improvement (P < .001).ConclusionsSymptomatic IPT occurred in 53 (3.3%) of the 1,602 primary THAs. Our findings suggest that leg lengthening as well as prominent acetabular cup in THAs can be associated with the development of IPT. Arthroscopic tenotomy was effective in relieving groin pain caused by IPT.  相似文献   

3.
《The Journal of arthroplasty》2019,34(10):2420-2426
BackgroundThe purpose of this study is to analyze the 10-year outcomes of cementless, modular total hip arthroplasty (THA) in adult patients who had high dislocation secondary to childhood pyogenic arthritis.MethodsWe retrospectively followed 56 consecutive patients who underwent cementless, modular THA for the late sequelae of childhood septic arthritis of the hip from 2001 to 2011. There were 23 men and 33 women with a mean age of 47 years (24 to 68). Of the 56 hips, 25 were classified as Crowe type III and 31 as type IV. Mean follow-up was 10.7 years.ResultsOne hip with a quiescent period of 23 years had recurrence of infection. Revision surgery was performed in 2 patients because of loosening and breakage of femoral stem and new infection with no correlation with childhood sepsis, respectively. The mean Harris hip scores improved from 44.2 points preoperatively to 87.5 points at final follow-up. Similarly, the Hip dysfunction and Osteoarthritis Outcome Score and hip pain also significantly improved at the latest follow-up. The mean acetabular cup abduction was 40.8° and the mean anteversion 27.8°, respectively. There were 5 cases of transient nerve palsy and 5 cases of intraoperative fracture.ConclusionTHA can reliably restore the abnormal anatomy and provide good results in these young and active patients who had high hip dislocation secondary to childhood pyogenic arthritis with a relatively high incidence of complications. However, these complications can be treated.  相似文献   

4.
BackgroundSquatting is an important function for many daily activities, but has not been well documented after total hip arthroplasty (THA). This study investigated the participation rate of squatting and in vivo kinematics during squatting.MethodsA survey questionnaire about squatting was mailed to patients who underwent primary THA and 328 patients returned acceptable responses. Additionally, 32 hips were evaluated for dynamic 3-dimensional kinematics of squatting using density-based image-matching techniques. Multivariate analyses were applied to determine which factors were associated with anterior liner-to-neck distance at maximum hip flexion.ResultsPatients who could easily squat significantly increased this ability postoperatively (23.5% vs 46%, P < .01). In 29.5% of the patients there was still no ability to squat after THA; the main reason was anxiety of dislocation (34.2%). Kinematic analysis revealed that maximum hip flexion averaged 80.7° ± 12.3° with 12.8° ± 10.7° of posterior pelvic tilt and 9.7 ± 3.0 mm of anterior liner-to-neck distance. Neither liner-to-neck, bone-to-bone, nor bone-to-implant contact was observed in any of the hips. Larger hip flexion and smaller cup anteversion were negatively associated with the anterior liner-to-neck distance at maximum hip flexion (P < .05).ConclusionPostoperatively, approximately 70% of patients squatted easily or with support. Anxiety of dislocation made patients avoid squatting after THA. In vivo squatting kinematics suggest no danger of impingement or subsequent dislocation, but excessively large hip flexion and small cup anteversion remain as risks.  相似文献   

5.
BackgroundOsteopetrosis is an inherited bone disease associated with high risk of osteoarthritis and fracture non-union, which can lead to total hip arthroplasty (THA). Bone quality and morphology are altered in these patients, and there are limited data on results of THA in these patients. The goals of this study were to describe implant survivorship, clinical outcomes, radiographic results, and complications in patients with osteopetrosis undergoing primary THA.MethodsWe identified 7 patients (9 hips) with osteopetrosis who underwent primary THA between 1970 and 2017 utilizing our total joint registry. The mean age at index THA was 48 years and included two males and five females. The mean follow-up was 8 years.ResultsThe 10-year survivorship free from any revision or implant removal was 89%, with 1 revision and 1 resection arthroplasty secondary to periprosthetic femoral fractures. The 10-year survivorship free from any reoperation was 42%, with 4 additional reoperations (2 ORIFs for periprosthetic femoral fractures, 1 sciatic nerve palsy lysis of adhesions, 1 hematoma evacuation). Harris hip scores significantly increased at 5 years (P = .04). Five hips had an intraoperative acetabular fracture, and 1 had an intraoperative femur fracture. All postoperative femoral fractures occurred in patients with intramedullary diameter less than 5 mm at a level 10 cm distal to the lesser trochanter.ConclusionPrimary THA in patients with osteopetrosis is associated with good 10-year implant survivorship (89%), but a very high reoperation (58%) and periprosthetic femoral fracture rate (44%). Femoral fractures appear associated with smaller intramedullary diameters.  相似文献   

6.
《The Journal of arthroplasty》2020,35(12):3621-3626
BackgroundThis study is prospectively conducted to evaluate surgical complications of monolithic dual mobility cup total hip arthroplasty (THA) in elderly patients with fractured neck of the femur.MethodsNinety-seven patients (97 hips) with displaced femoral neck fracture who gave informed consent for participation were prospectively enrolled. Their mean age was 76.6 years (range, 60-95 years), and the mean bone mineral density T-score of neck of the femur was −2.8 (range, −1.2 to −5.5). All patients underwent THA with monolithic dual mobility cup, and computed tomography scans were obtained to evaluate radiographic parameters including anteversion, inclination, and loosening of acetabular cups, and periprosthetic acetabular fractures.ResultsWith regard to cup orientation, mean inclination angle was 40.2° (range, 23.5°-63°) and mean anteversion was 32.6° (range, 7°-66.2°). The proportion of surgical outliers was 10.3% (10/97) in inclination and 35.1% (34/97) in anteversion. Early cup loosening within 2 weeks was detected in 2 hips. Periprosthetic acetabular fractures were identified in 6 hips (6/97, 6.2%). Of the 6 fractures, 5 nondisplaced fractures were healed with conservative management, but 1 fracture with displacement eventually led to cup loosening and the patient underwent revision surgery. Reoperation rate of the monolithic dual mobility cup was 4.1% (4/97).ConclusionThe use of the monolithic dual mobility was associated with improper cup fixation and periprosthetic acetabular fractures in the elderly with poor bone stock, although the dual mobility cup lowered the risk of early dislocation after THA.  相似文献   

7.
BackgroundIliopsoas tendinopathy is a cause of groin pain following total hip arthroplasty (THA). With the anterior approach becoming increasingly popular, our aim was to determine the prevalence of iliopsoas tendinopathy following anterior approach THA, to identify risk factors and to determine an influence on patient-reported outcomes.MethodsThis is a retrospective case-control study of prospectively recorded data on 2,120 primary anterior approach THA (1,815 patients). The diagnosis of iliopsoas tendinopathy was based on (1) persistent postoperative groin pain, triggered by hip flexion; (2) absence of dislocation, infection, loosening, or fracture; and (3) decrease of pain after fluoroscopy-guided iliopsoas tendon sheet injection with xylocaine and corticosteroid. Outcomes included hip reconstruction (inclination/anteversion and leg-length), complication rates, reoperation rates, and patient-reported outcomes including Hip disability and Osteoarthritis Outcome Score.ResultsForty four patients (46 THAs) (2.2%) were diagnosed with iliopsoas tendinopathy. They were younger than patients who did not have iliopsoas tendinopathy (51 years [range, 27-76] versus 62 years [range, 20-90]; P < .001). Logistic regression analyses demonstrated that younger age (P < .001) and presence of a spine fusion (P = .008) (odds ratio 4.6) were the significant predictors of iliopsoas tendinopathy. These patients had lower Hip disability and Osteoarthritis Outcome scores, reported more often low back pain (odds ratio 4.8), and greater trochanter pain (odds ratio 5.4).ConclusionWe found an incidence of 2.2% of iliopsoas tendinopathy patients after anterior approach THA that compromised outcomes. Younger age and previous spine fusion were identified as most important risk factors. These patients were 5 times more likely to report low back pain and greater trochanter pain post-THA.  相似文献   

8.
Trends in Total Hip Arthroplasty Implant Utilization in the United States   总被引:1,自引:0,他引:1  
Total hip arthroplasty (THA) implant usage has evolved as experience has been gained with newer implant designs. The purpose of this study was to characterize trends in THA implant usage between 2001 and 2012. The Orthopedic Research Network, which includes 174 hospitals and ~ 105,000 THA, was used to evaluate trends in fixation, bearings, acetabular cup and liner, and femoral head usage. In 2012, 93% of THAs were cementless; 56% of THA bearings were metal-HXLPE; and 35% were ceramic-HXLPE. 99% of acetabular cups were modular. 61% of femoral heads were metal, 39% were ceramic, 51% were 36 mm, and 28% were 32 mm. THA implant usage trends favor cementless fixation, metal-on-polyethylene or ceramic-on-polyethylene bearings, modular acetabular cups, and large diameter femoral heads.  相似文献   

9.

Background

Second-generation, metal-on-metal total hip arthroplasty (MoM THA) using a 28-mm head has shown favorable results compared with large head MoM THA. The purpose of this study is to evaluate the long-term outcomes of cementless primary MoM THA with a 28-mm head and the incidence of osteolysis using computed tomography.

Methods

A total of 92 patients (53 men and 39 women) who underwent primary cementless MoM THA (114 hips) with a 28-mm head were enrolled in this study. Their mean age was 46.2 years at the time of surgery. The mean follow-up duration was 20 years. The Harris hip score, presence of thigh or groin pain, radiographic results, presence of peri-implant osteolysis, histologic analysis, and Kaplan-Meier survival curves were evaluated.

Results

The mean preoperative Harris hip score of 50.5 improved to 85.1 at the final follow-up. Eight patients (8 hips) experienced groin pain, but none had thigh pain. Twelve revisions (6.2%) were performed including 10 hips for aseptic loosening with osteolysis and 2 hips for periprosthetic fracture around the stem. At 23 years, 91% of patients were free from revision of the acetabular component due to aseptic loosening and 90.1% were free from revision of both femoral and acetabular components due to any reason. Osteolysis was identified around the cup in 12 cases (10.5%) and around the stem in 7 cases (6.1%).

Conclusion

MoM THA with a 28-mm head showed a relatively low rate of aseptic implant loosening at a mean follow-up of 20 years.  相似文献   

10.
Recent studies suggest that the tapered interface between stem and femoral head may be a substantial source of cobalt and chromium ion release after metal-on-metal (MOM) total hip arthroplasty (THA). This study compared patient ion levels after MOM hip resurfacing (HR) and MOM THA performed with identical acetabular components. 110 HRs were compared with 22 THAs. All had well-oriented components, unilateral implants, and serum ion studies beyond one year post-operatively. The HR group’s median cobalt value was 1.11 μg/L vs. 2.86 μg/L for the THA patients. The HR group’s median chromium value was 1.49 μg/L vs. 2.94 μg/L for THA. Significantly higher THA ion levels suggest a source of ions other than the MOM bearing itself.  相似文献   

11.
Little has been reported on knee pain after total hip arthroplasty (THA). The purpose of this study was to investigate the incidence and mechanism of knee pain after THA. Two hundred fifty-two patients with hip dysplasia were clinically and radiographically assessed for knee pain before and after THA. Incidences of knee pain and patellofemoral alignment were analyzed with reference to postoperative change in leg length, femoral anteversion, and the femoral offset. Anterior knee pain was present in 16 patients (7.3%). Lateral patellar tilt was increased in all patients with knee pain and significantly larger compared to that seen in patients without knee pain. The increased patellar tilt disappeared within 3 months, but symptoms in 4 patients persisted for more than 3 months. The patellar tilt was significantly related to the amount of leg lengthening. This study demonstrates that THA influences the patellofemoral joint via leg lengthening and causes anterior knee pain.  相似文献   

12.
BackgroundThe efficacy of contemporary monoblock dual-mobility (DM) cups to prevent dislocations in total hip arthroplasty (THA) is well reported, but there is little published data on their mid- to long-term outcomes. The authors aimed at reporting the 10-year survival of a contemporary DM cup as well as its clinical and radiographic outcomes.MethodsFrom a retrospective consecutive multicentric series of 516 patients (541 hips) that received uncemented THA between June 2007 and June 2010, 6 patients (6 hips) had cup and stem revisions, 5 patients (5 hips) had isolated stem revision, and 2 patients (2 hips) had isolated insert revision. A total of 103 patients (111 hips) died with their original implants, and 41 patients (42 hips) were lost to follow-up. This left 358 patients (375 hips) for clinical assessment at a median follow-up of 8.7 years (range, 6.8-10.5 years), including 279 patients (290 hips) with postoperative radiographs. Implant survival was calculated using the Kaplan-Meier method, and multivariable analyses were performed to determine whether clinical outcomes are associated with patient or surgical factors.ResultsThe 10-year survival considering revision for aseptic loosening as end point was 100% for the cup and 99.2% for the stem. No dislocations were observed, and radiographic assessment revealed 1 acetabular granuloma (0.3%), but no radiolucencies nor fractures. The Harris hip score improved from 49.6 ± 15.5 to 85.2 ± 14.5, and the postoperative Oxford hip score was 19.2 ± 7.6. Multivariable analyses revealed that improvement in Harris hip score increased with cup diameter (beta, 1.28; P = .039).ConclusionOur data confirmed satisfactory midterm outcomes of uncemented THA using a contemporary DM cup, with no dislocations nor cup revisions due to aseptic loosening.Level of EvidenceLevel IV, retrospective cohort study.  相似文献   

13.
Developmental dysplasia of the hip (DDH) is accompanied by morphological alterations on both the acetabular and the femoral side. Total hip arthroplasty (THA) provides effective treatment in cases of neglected DDH but requires elaborate preoperative planning. To determine the morphological changes resulting from the dysplasia, the anatomic acetabular position, the height of the femur head dislocation, the height of the femur head dislocation, and the combined anteversion must all be established. In addition, a vital and complicated process of strategizing leg length balance must be conducted in cases of severe DDH. Each type of leg length discrepancy (LLD), including bony and functional and anatomical LLD, should be evaluated in the context of the presence or absence of a fixed pelvic tilt. Moreover, with severe unilateral dislocated hips, a more inferior change in the original rotational center of the hip must be accounted for. Due to these multiple morphological changes, the accurate size of the prosthesis and the cup position are difficult to predict. In comparison with other methods, CT scan‐based 3‐dimensional templating provides the best accuracy. Despite the presence of anatomic alterations, various types of acetabular and femoral prostheses have been developed to treat hip dysplasia. Both cemented and cementless cups are used in DDH cases. In DDH accompanied by insufficient acetabular bone stock, a cemented cup combined with bone graft provides a reliable treatment. Monoblock stems can be used when the combined anteversion is less than 55°, and a modular stem system when this parameter is greater than 55°. Customized stems can be designed for DDH coupled with severe proximal femoral distortion. A ceramic‐on‐ceramic bearing is considered optimal for young DDH patients.  相似文献   

14.
《The Journal of arthroplasty》2022,37(6):1118-1123
BackgroundPreserving bone stock in younger and more active patients after total hip arthroplasty (THA) is important for future revision. Newer prosthesis designs, including short femoral stems and isoelastic acetabular cups, are likely to preserve more bone stock. However, long-term follow-up studies on bone remodeling after short-stem THA with an isoelastic monoblock acetabular cup are few. Therefore, we evaluated bone preservation after THA using these prostheses at a 5-year follow-up.MethodsThis prospective observational study is a 5-year follow-up of our previously reported 2-year observational study on the same cohort of patients. We included 45 patients with primary osteoarthritis treated with a calcar-guided femoral short-stem prosthesis and a monoblock press-fit acetabular cup. We evaluated bone mineral density (BMD) around the prostheses using dual-energy X-ray absorptiometry and reported functional outcomes preoperatively and at 3, 12, 24, and 60 months postoperatively. All complications were recorded.ResultsAt the final follow-up, the BMD was comparable with that at 24 months in Gruen zones 3, 4, 5, 6, and 7, whereas it significantly differed in Gruen zones 1 (P < .0001) and 2 (P < .004). On the acetabular side, the BMD leveled off similarly in all DeLee and Charnley zones between 24 and 60 months (P > .05). Moreover, all measured clinical outcomes significantly improved (P < .001). One perioperative dislocation was reported.ConclusionPatients undergoing THA with a calcar-guided femoral short-stem prosthesis and a monoblock acetabular cup can expect preservation of bone stock over a longer follow-up with excellent clinical outcomes and few complications.  相似文献   

15.

Background

Noise after ceramic-on-ceramic (CoC) total hip arthroplasty (THA) is a well-recognized problem. Computer navigation has been shown to achieve desired implant orientation. Our aim was (1) to compare the incidence of noise between navigated and conventional CoC THAs and (2) to determine the factors associated with noise.

Methods

All patients undergoing CoC THA between March 2009 and August 2012 were considered for this study. Information regarding hip noise was obtained via telephone or postal interview. A comparable cohort of patients in navigated and conventional groups was used to evaluate the incidence of noise.

Results

A total of 375 CoC THAs using the same implant (202 navigated and 173 conventional) were evaluated. Patients <65 years of age had significantly greater incidence of noise (22.4% vs 6.1%; P < .001). To ensure similarity, a subgroup of cohort <65 years and a 32-mm head size was used to compare the incidence of noise between the navigated (68 THAs) and conventional (118 THAs) groups. Overall incidence of noise was significantly greater in the conventional group (28%) as compared with the navigated group (10%; P = .005). The relative risk of noise for the conventional vs the navigated group was 2.7 (P = .01), and for squeaking was 1.9 (P = .2). Squeaking THAs had significantly lower cup anteversion (13.4° ± 5.2°) as compared with the silent THAs (17.6° ± 6.9°; P = .01).

Conclusion

Navigated CoC THAs were 2.7× less likely to have noise as compared with the conventional ones. Squeaking THAs had significantly lower cup anteversion as compared with the silent ones. Patients of age <65 years had significantly greater incidence of noise after CoC THA.  相似文献   

16.
BackgroundMalposition of the acetabular component during total hip arthroplasty (THA) is associated with increased risk of dislocation, reduced range of motion, and accelerated wear. The purpose of this study is to compare cup positioning with a portable, accelerometer-based hip navigation system and conventional surgical technique.MethodsIn a prospective, randomized, clinical study, cups were implanted with a portable, accelerometer-based hip navigation system (navigation group; n = 55) or conventional technique (conventional group; n = 55). THA was conducted in the lateral position and through posterior approach. The cup position was determined postoperatively on pelvic radiograph and computed tomography scans.ResultsAn average cup abduction of 39.2° ± 4.6° (range, 27° to 50°) and an average cup anteversion of 14.6° ± 6.1° (range, 1° to 27.5°) were found in the navigation group, and an average cup abduction of 42.9° ± 8.0° (range, 23° to 73°) and an average cup anteversion of 11.6° ± 7.7° (range, −12.1° to 25°) in the conventional group. A smaller variation in the navigation group was indicated for cup abduction (P = .001). The deviations from the target cup position were significantly lower in the navigation group (P = .001, .016). While only 37 of 55 cups in the conventional group were inside the Lewinnek safe zone, 51 of 55 cups in the navigation group were placed inside this safe zone (P = .006). The navigation procedure took a mean of 10 minutes longer than the conventional technique.ConclusionUse of the portable, accelerometer-based hip navigation system can improve cup positioning in THA.  相似文献   

17.
BackgroundThe objective of this study is to evaluate the incidence, natural history, response to treatment, and risk factors for anterior iliopsoas impingement (AIPI) after direct anterior approach (DAA) total hip arthroplasty (THA).MethodsBetween January 1, 2009 and January 4, 2014, 600 patients (655 hips) who underwent primary DAA THA were retrospectively reviewed. AIPI incidence was calculated. Natural history and response to a stepwise treatment approach was assessed. Radiographic anterior acetabular component overhang was measured. Asymptomatic controls were used to identify risk factors for the development of AIPI.ResultsIn total, 518 patients (559 hips) met the inclusion criteria. The incidence of AIPI was 32/559 (5.7%). Symptom resolution occurred in 22/32 (68.8%) patients at final follow-up. Nonoperative management was successful in 15/32 (46.9%) patients. Operative intervention resulted in symptom resolution in 5/8 (62.5%) patients. On univariate analysis, female gender (odds ratio [OR] 2.79), acetabular component to native femoral head diameter ratio above 1.1 (OR 3.85), and any measurable overhang (OR 7.07) significantly raised the risk of AIPI, while increasing native femoral head diameter was protective for AIPI (OR 0.83).ConclusionAIPI is a cause of groin pain after DAA THA, which often improves with conservative measures. Significant predisposing factors for AIPI include female gender, small native femoral head diameter, increased acetabular component to femoral head diameter ratio, and most notably, any measurable acetabular component overhang.Level of EvidenceLevel III, retrospective cohort study.  相似文献   

18.
BackgroundA previously published calculator used age, preoperative modified Harris Hip Score, femoral anteversion, preoperative lateral center-edge angle, revision surgery, and acetabular and femoral cartilage damage to provide risk estimates for conversion rate of hip arthroscopy to total hip arthroplasty (THA). Validation for this calculator has not been established. The purpose of this study is to (1) validate the previously published hazard ratios for the predictor factors in a new cohort of hip arthroscopies with minimum 2-year follow-up and (2) determine the accuracy of the calculator at determining conversion rates to THA at 2 and 4 years of follow-up.MethodsHazard ratios for THA conversion were calculated using data between February 2008 and November 2016 and compared to the previously published results, which comprised the training set. Actual conversion to THA data was used to evaluate the accuracy of the calculator.ResultsOf the 1400 patients examined, THA conversion occurred in 101 (7.2%) patients at an average of 28.4 ± 22.9 months (0.2-115.8) after hip arthroscopy. The hazard ratios for the validation set compared to the training set were as follows: age 1.06 versus 1.06; modified Harris Hip Score 0.97 versus 0.98; femoral anteversion 0.99 versus 0.97; lateral center-edge angle 0.98 versus 0.93; and revision surgery 1.77 versus 2.40. Accuracy of the risk calculator at 2 years was 75% (Harrell C-statistic 0.806) and at 4 years was 73% (C-statistic 0.797).ConclusionThis study found 75% and 73% accuracy at 2 and 4 years respectively in calculating risk of conversion of hip arthroscopy to THA using a previously published calculator. As this calculator relies on intraoperative data, the major benefit it provides is information regarding patient prognosis postoperatively. Furthermore, it could potentially enable the surgeon, after receiving proper surgical consent, to decide on immediate conversion to THA.Level of EvidenceIII, retrospective cohort.  相似文献   

19.
BackgroundThis study compares the long-term functional, radiographic, and computed tomography scan outcomes and implant survivorship of ceramic-on-ceramic total hip arthroplasty (C-O-C THA) and ceramic-on-highly cross-linked polyethylene total hip arthroplasty (C-O-HXLPE THA) in the same patients.MethodsIn this randomized, prospective trial conducted between January 1999 and April 2003, 133 patients (266 hips) younger than 55 years were enrolled. Each patient received C-O-C THA in 1 hip and a C-O-HXLPE THA in the other. The mean follow-up was 17.1 years (range, 15-18 years); there were 84 men and 49 women with a mean age of 53 ± 7 years (range, 25-55 years).ResultsAt the latest follow-up, mean Harris hip scores (94 vs 93 points; P = .861), pain scores (43 vs 42 points; P = .651), and patient satisfaction scores (7.8 vs 7.6 points; P = .379) were not different between the 2 groups. Eight hips (3%) in the C-O-C THA had an audible squeaking sound. The mean annual penetration rate of HXLPE was 0.0162 ± 0.032 mm per year. No osteolysis was recorded on radiographs or computed tomography scans in either group. At 17.1 years, the survival rate of the acetabular component was 97% in the C-O-C bearing group and 98% in the C-O-HXLPE bearing group (P = .923). The survival rate of the femoral component was 99% in both groups.ConclusionBoth C-O-C THA and C-O-HXLPE THA functioned well, with no osteolysis at mean of 17.1-year follow-up.  相似文献   

20.
《The Journal of arthroplasty》2021,36(11):3716-3721
BackgroundDual-mobility (DM) bearings reduce instability in revision total hip arthroplasty (THA); however, DM bearings are costly and reports of corrosion have recently emerged. Furthermore, no study has compared DM to standard bearings with large diameter femoral heads ≥40-mm. This study’s purpose was to compare postoperative dislocation rates of standard and DM bearings with large femoral heads after revision THA.MethodsA retrospective review of 301 consecutive revision THAs was performed. The mean follow-up was 37.1 months. To isolate the effect of the double articulation, standard and DM bearings with femoral heads ≥40-mm were compared. Outcomes were postoperative dislocation and reoperation within 90 days.ResultsThe cohort consisted of 182 standard bearings and 75 DM bearings. There were no differences in revision indication comparing standard and DM bearings (P = .258). Overall dislocation rate was 8.6% (22 of 257). The dislocation rate was 5.7% for standard bearings with ≥40-mm femoral heads compared with 6.9% in DM bearings with ≥40-mm femoral heads (P = 1.000). In multivariate analysis, lower body mass index (odds ratio 1.72), female sex (odds ratio 2.01), and decreased outer femoral head diameter–to–cup component size ratio (odds ratio 1.64) were predictors of postoperative dislocation regardless of bearing type.ConclusionThis study showed no difference in dislocation rates between standard and DM bearings when comparing similar femoral head diameters of ≥40-mm used in revision THAs. Considering the cost and potential deleterious issues associated with additional interfaces, DM bearings should be used judiciously considering similar results may be achieved with single-articulation bearings using large femoral heads.Level of EvidenceLevel III.  相似文献   