首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
PURPOSE: To evaluate the safety and clinical effectiveness of a covered retrievable expandable nitinol stent for the treatment of malignant tracheobronchial stricture and/or esophagorespiratory fistula (ERF). MATERIALS AND METHODS: With fluoroscopic guidance, stents were placed in 35 symptomatic patients with malignant tracheobronchial stricture and/or ERF in most cases caused by lung or esophageal cancer. The site of stricture was most commonly at the trachea or left main bronchus. If there were complications, the stent was removed with a retrieval set. Nine patients had combined symptomatic ERF. RESULTS: A total of 47 tracheobronchial stents were placed and were technically successful and well-tolerated in all patients. Improvement of dyspnea was achieved in 92% of the patients (24 of 26 patients). Associated ERF in nine patients was effectively treated with tracheobronchial stent placement with or without esophageal stent placement. Stent migration, tumor overgrowth, symptomatic sputum retention, and hemoptysis occurred in 17% (6/35), 6% (2/35), 20% (7/35), and 17% (6/35) of patients, respectively. There were no documented cases of tumor ingrowth. Stent removal was performed easily in five patients when stent migration (n = 2), severe pain (n = 1), tumor overgrowth (n = 1), or persistent gastrobronchial fistula (n = 1) developed. All patients died 2 days to 26 weeks (mean, 9.62 weeks) after stent placement because of disease progression (n = 18), pneumonia (n = 9), hemoptysis (n = 5), or unknown cause (n = 3). CONCLUSION: Use of a covered retrievable expandable nitinol stent is a safe and effective method for relieving dyspnea. This procedure contributed to improved quality of life for patients with malignant tracheobronchial stricture and/or ERF. Stent retrievability was useful in resolving stent-related complications.  相似文献   

2.
PURPOSE: To evaluate the clinical effectiveness of polytetrafluoroethylene (PTFE)-covered retrievable expandable nitinol stents in tracheobronchial strictures. MATERIALS AND METHODS: With fluoroscopic guidance, PTFE-covered retrievable expandable nitinol stents were placed in 15 symptomatic patients with benign (n = 6) or malignant (n = 9) tracheobronchial strictures. Complications and improvement in respiratory status were evaluated. Stents were removed electively 6 months after placement in benign strictures or if complications occurred. Membrane degradation or separation from the wire mesh was evaluated in removed stents. RESULTS: A total of 17 stents were successfully placed and were well tolerated in all patients. Sputum retention, stent migration, and tissue hyperplasia occurred in 23.5% (n = 4), 17.6% (n = 3), and 17.6% (n = 3) of stents, respectively. A total of 11 stents were successfully removed electively 6 months after placement (n = 4) or when complications occurred (n = 7). All 11 such stents were removed without difficulty with use of standard techniques, antecedent balloon dilation being necessary in two cases as a result of tissue hyperplasia. No removed stent showed signs of membrane degradation, and two removed stents showed signs of membrane separation from the mesh. CONCLUSIONS: PTFE-covered retrievable expandable nitinol stents were effective in the treatment of tracheobronchial strictures. Stent removal was easy with use of standard techniques, and no removed stent showed evidence of membrane degradation.  相似文献   

3.
Song HY  Park H  Suh TS  Ko GY  Kim TH  Kim ES  Park T 《Radiology》2003,226(2):433-440
PURPOSE: To investigate the clinical effectiveness of a covered, retrievable, expandable nitinol stent in treating traumatic urethral strictures near the external sphincter. MATERIALS AND METHODS: The stent was 10 mm in diameter when fully expanded and 40-50 mm long. To make it removable, two nylon drawstrings were attached to its lower inner margin. Twelve consecutive men (19-67 years; mean age, 47 years) with traumatic urethral strictures near the external sphincter that were refractory to endoscopic urethrotomy were treated. With fluoroscopic guidance, a stent was placed to completely bridge the external sphincter. The stent was electively removed with a retrieval hook wire 2 months after placement. Stent placement and removal were successful in all patients, with no procedural complications. RESULTS: Mean maximum urine flow rate was 5 mL/sec (range, 3-7 mL/sec) before stent placement and 27 mL/sec (range, 16-40 mL/sec) at 1 week after placement. During the mean follow-up of 20 months (range, 2-37 months) after the first stent removal, strictures recurred in eight of 12 patients. For the eight patients with recurrence, a second stent was placed and 4 months later was removed from seven of the eight patients. During the mean follow-up of 18 months (range, 4-32 months) after the second stent removal, strictures recurred in two patients, in whom a third stent was placed and then removed 4 months later, with good results. Four (33%) of 12 patients, five (62%) of eight patients, and two (100%) of two patients were successfully treated with placement of the first stent, the second stent, and the third stent, respectively. In the remaining patient, the second stent remains in place. CONCLUSION: Placement of a covered, retrievable, expandable nitinol stent seems to be effective in treating urethral strictures near the external sphincter and warrants further investigation.  相似文献   

4.
Purpose: To assess the safety and clinical effectiveness of the parallel placement of covered retrievable expandable metallic stents in the palliative treatment of malignant esophageal and tracheobronchial strictures.

Material and Methods: Under fluoroscopic guidance, parallel stents were placed in 12 symptomatic patients with both malignant esophageal and tracheobronchial strictures. Seven of these 12 patients also had an esophagorespiratory fistula (ERF) and one patient had an esophagocutaneous fistula. Technical success, clinical improvement, complications, and survival rates were evaluated.

Results: A total of 28 esophageal and airway stents were successfully placed. The grade of dysphagia and dyspnea score significantly decreased after stent placement (P = 0.002 and 0.003, respectively). ERF and esophagocutaneous fistula were sealed off in all eight patients after esophageal stent placement; however, the esophagocutaneous fistula reopened 1 month later. Complications included stent migration or expectoration (n = 3), tracheal compression by the esophageal stent (n = 3), new fistula development due to covering membrane degradation of the esophageal stent (n = 1), and symptomatic sputum retention (n = 1). Stent removal was easily performed for two stents; one migrated stent and the other with covering membrane degradation. All 12 patients died within the mean survival period of 72.50 days (range 7-375 days).

Conclusion: Parallel placement of covered retrievable expandable metallic stents is safe and effective for the palliative treatment of malignant esophageal and tracheobronchial strictures.  相似文献   

5.
Temporary placement of a polytetrafluoroethylene (PTFE)-covered retrievable expandable nitinol stent was performed to treat a benign anastomotic duodenojejunal stricture that was refractory to repeated balloon dilation procedures. The procedure provided a favorable outcome for the patient and was completed without complications. This result suggests that successful treatment of benign strictures of the gastric outlet or duodenum is possible with use of retrievable stents.  相似文献   

6.
7.
Song HY  Shim TS  Kang SG  Jung GS  Lee DY  Kim TH  Park S  Ahn YM  Kim WS 《Radiology》1999,213(3):905-912
A polyurethane-covered retrievable expandable stent was placed in 13 patients with tracheobronchial strictures. In four patients with benign strictures, the stent was removed with use of a retrieval hook 2-6 months after placement. After stent removal, three of the four patients did not need further treatment. The retrievable stent warrants further investigation in the treatment of tracheobronchial strictures.  相似文献   

8.
Covered retrievable expandable nitinol stents were successfully placed in nine patients with tuberculous bronchial strictures refractory to balloon dilation. Complications included stent migration (n = 1) and tissue hyperplasia at the proximal portion of the stent (n = 2). During the follow-up period (5-52 months), stricture recurred in three of five patients (60%) after temporary stent placement for 2 months, whereas stricture did not recur in the other four patients after temporary stent placement for 6 months. Temporary placement of covered retrievable stents appears to be an effective method for the treatment of patients with tuberculous bronchial strictures refractory to balloon dilation.  相似文献   

9.
Purpose: To evaluate the preliminary clinical efficacy and retrievability of a covered, retrievable, metallic hinged stent in the treatment of bronchial stump fistula (BPF).

Material and Methods: Between April 2003 and March 2005, eight patients with bronchial stump fistula after pneumonectomy or lobectomy were treated with two types of covered, retrievable, metallic hinged stents. Type A stent was placed in six patients and type B in two under fluoroscopic guidance. The stent was removed with a retrieval set when BPF was healed or complications occurred.

Results: Stent placement in the bronchial tree was technically successful in all patients, without procedure-related complications. Immediate closure of the BPF was achieved in all patients after the procedure. Stents were removed from all patients but one. Removal of the stents was difficult in two patients due to tissue hyperplasia. Patients were followed for 4-16 months. Placement of the stents remained stable in all patients except one due to severe cough. Permanent closure of BPF was achieved in seven (87.5%) of eight patients.

Conclusion: Use of a covered, retrievable, expandable, metallic hinged stent is a simple, safe, and effective procedure for the closure of bronchial stump fistula. Retrieval of the stent seems feasible.  相似文献   

10.
11.

Purpose

To report the use of a newly constructed, covered, retrievable, expandable nitinol stent with barbs to overcome the problem of stent migration associated with conventional covered prostatic expandable stents and to evaluate prospectively the technical feasibility and clinical effectiveness of the stents in patients with benign prostatic hyperplasia (BPH).

Materials and Methods

A covered retrievable expandable nitinol stent with four barbs was placed with use of an 18-F stent delivery system in seven consecutive patients with symptomatic BPH who had high operative risks. Age range of patients was 62–83 years (mean 74 years). In cases in which the stent migrated, it was replaced with a stent with eight barbs. The stents were routinely removed 4 months after placement using a 21-F stent removal set.

Results

Stent placement was technically successful and well tolerated in six of the seven patients. The remaining patient needed a second stent placement after removal of the first stent. The stent with four barbs migrated into the urinary bladder in four patients (57%); three of these patients received a second stent with eight barbs with good results, and the fourth patient did not need further treatment because his symptoms improved. Routine removal of the stent 4 months after placement was performed in three of the seven patients with good results.

Conclusions

Retrievable stents with eight barbs seem to overcome the problem of stent migration associated with conventional prostatic expandable stents. Preliminary results suggest that stents with barbs are both feasible and effective in patients with BPH.  相似文献   

12.
Song HY  Jung HY  Park SI  Kim SB  Lee DH  Kang SG  Il Min Y 《Radiology》2000,217(2):551-557
PURPOSE: To investigate the safety and clinical effectiveness of covered retrievable expandable nitinol stents in 25 patients with a benign esophageal stricture. MATERIALS AND METHODS: Under fluoroscopic guidance, covered retrievable expandable nitinol stents were placed in 25 patients with a benign esophageal stricture and were removed with a retrieval hook 1-8 weeks later. RESULTS: Stent placement was successful in all patients, with no procedural complications. After stent placement, all patients could ingest solid food. The stents were successfully removed from all but two patients. One patient passed the stent via the rectum, and the other regurgitated a high cervical stent. After stent removal, one patient developed a small esophagobronchial fistula, which spontaneously sealed within 1 week of stent removal. After stent removal or migration, all patients could ingest solid food. During follow-up (mean, 13 months; range, 2-25 months) after stent removal or migration, 12 patients maintained their improvement in dysphagia and needed no further treatment. Thirteen patients with recurrence were treated by means of repeat balloon dilation. CONCLUSION: Use of retrievable expandable nitinol stents seems to be a safe and effective method of treatment in selected patients with benign esophageal strictures.  相似文献   

13.
Carotid blowout is a devastating complication in patients with head and neck malignancy. A covered stent offers an alternative to treatment of a carotid blowout patient thought to be at high risk for surgery or carotid occlusion. Stent placement in the common carotid artery or carotid bulb is a technical challenge because of large luminal diameter and luminal calibre discrepancy between internal carotid artery and common carotid artery. We present four patients with common carotid rupture and massive bleeding who were treated with self-expanding covered stents, among them, two cases were treated with newly designed self-expanding polytetrafluoroethylene (PTFE)-covered nitinol stents.  相似文献   

14.
A 70-year-old woman presented with a large femoropopliteal aneurysm. A covered nitinol stent was implanted successfully and complete exclusion of the aneurysm was achieved. At follow-up 5 months later the stent was still patent and the patient was free of symptoms. However, moderate stenosis was seen at the proximal end of the stent.  相似文献   

15.
16.
17.
18.
PURPOSE: To assess whether coaxial placement of uncovered and covered expandable nitinol stents overcomes the disadvantages of the increased migration rate seen with covered stents and the tumor ingrowth seen in uncovered stents in the treatment of malignant gastric outlet obstructions. MATERIALS AND METHODS: Two types of expandable nitinol stent were designed: an uncovered stent and a covered stent. Under fluoroscopic guidance, the uncovered and covered stents were placed coaxially with complete overlap in 39 consecutive patients with malignant gastric outlet obstruction caused by stomach cancer. Food intake capacity was graded on a scale of 0-4. Stent patency rate was estimated by the Kaplan-Meier method. RESULTS: Technical success rate was 97% (38 of 39 patients). After stent placement, food intake capacity improved at least one grade in 36 patients. Stent migration occurred in three patients (8%), that is, partial (n = 2) or complete (n = 1) upward migration of the inner covered stent into the stomach. Two of these patients were treated by placement of an additional covered stent. During the mean follow-up period of 134 days (range, 15-569 d), 10 patients developed recurrent symptoms of obstruction with tumor overgrowth being the most common cause. Nine underwent placement of an additional covered stent with good results. The median period of primary stent patency was 157 days (mean, 278 d). The 30-, 60-, and 180-day patency rates were 97%, 91%, and 39%, respectively. Four patients (10%) died within 1 month after the procedure. CONCLUSION: Coaxial stent placement technique seems to contribute to decreasing the migration rate of the stent and decrease the rate of recurrent obstruction by preventing or delaying tumor ingrowth.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号