 共查询到18条相似文献,搜索用时 140 毫秒
1.
目的初步探讨双源CT双能量技术扫描对急性坏死性胰腺炎影像诊断的价值。方法回顾性分析32例确诊急性坏死性胰腺炎患者的双源CT双能量门静脉期增强图像,测量、计算并评估80kV、140 kV和加权融合120kV图像中的胰腺实质-坏死灶CT差值、胰腺实质-坏死灶对比噪声比以及图像主观诊断评分。结果 80 kV、140 kV和加权融合120 kV图像中胰腺实质-坏死灶CT差值分别为(67.22±21.11)HU、(42.91±15.12)HU、(48.78±16.13)HU;胰腺实质-坏死灶对比噪声比分别为8.35±3.63、5.89±2.67、7.72±3.58;图像主观诊断评分分别为3.87±0.34、3.28±0.81、3.56±0.67。3组图像中的胰腺实质-坏死灶CT差值、胰腺实质-坏死灶对比噪声比以及图像主观诊断评分之间差异均有统计学意义(P<0.05)。其中80 kV图像的胰腺实质-坏死灶CT差值、胰腺实质-坏死灶对比噪声比和图像主观诊断评分均高于140 kV和加权融合120 kV图像。结论急性坏死性胰腺炎患者双源CT双能量门静脉期增强扫描,80 kV图像对坏死灶的显示优于140 kV和加权融合120 k...  相似文献   

2.
目的 初步探讨双源CT双能量技术扫描对急性坏死性胰腺炎影像诊断的价值.方法 回顾性分析32例确诊急性坏死性胰腺炎患者的双源CT双能量门静脉期增强图像,测量、计算并评估80 kV、140 kV和加权融合120kV图像中的胰腺实质-坏死灶CT差值、胰腺实质-坏死灶对比噪声比以及图像主观诊断评分.结果 80 kV、140 k...  相似文献   

3.
目的 初步研究双源CT双能扫描多种衍生序列对胰腺癌诊断的价值.方法 回顾性分析23例确诊胰腺癌患者的双源CT双能扫描图像(胰腺实质期,100kVp/230mAs和Sn140kVp/178mAs),经后处理得到单能谱60key图像、单能谱80kev图像、单能谱100key图像、单能谱120kev图像、线性融合图像、非线性融合图像及碘图图像.测量并计算上述图像及100kVp原始图像中的胰腺实质肿瘤cT差值、肿瘤/胰腺实质强化比值及胰腺实质-肿瘤对比噪声比,评价多种双能扫描后处理技术得到的系列图像对胰腺癌组织的分辨能力及其诊断价值.结果 8组图像间的胰腺实质肿瘤CT差值、肿瘤/胰腺实质强化比值及胰腺实质-肿瘤对比噪声比差异均有统计学意义(P<0.05),其中胰腺实质肿瘤CT差值最大的序列是单能谱60kev,为(77.53±23.42)HU,肿瘤/胰腺实质强化比值最小的序列是碘图,为0.39 ±0.12,胰腺实质-肿瘤对比噪声比最大的序列是碘图,为4.08±1.46.结论 双源CT的双能扫描模式能够经多种后处理方法获得多种衍生序列,这些序列的综合应用能够进一步提高多层螺旋CT对诊断胰腺癌灶的敏感性.  相似文献   

4.
目的 利用CT模拟机(西门子Sensation Open),分析水模体日常质量检测多次重复实验的结果 ,评价水的CT值和图像噪声的短期稳定性。方法 使用与西门子CT模拟机配套的水模体,调用日常的检测质量(DQC)程序进行质控检测。DQC程序使用标称管电压120 kV和140 kV两种检测条件。通过质控检测,得到两种条件下水的CT值和图像噪声在30分钟内的10次检测数据,进行统计分析和比较研究。结果 120kV条件,第1至6层(S1-S6)水的CT值(单位:HU)分别为:0.94±0.34,1.66±0.30,0.8 7±0.3 7,-0.8 3±0.3 4, 0.3±0.4 2,0.29±0.45。140 kV条件,第1至6层水的CT值(单位:HU)分别为:-0.26±0.45,0.64±0.37,-0.14±0.31,-2.09±0.33,-1.33±0.34,-1.35±0.31。120kV与140kV条件第1至6层水的CT值在10次检测中的变化范围分别为(0.21~1.28)HU、(-1.23~-0.30)HU,第1次测量结果 显著大于其余各次。120 kV和140 kV条件图像...  相似文献   

5.
目的探讨双源CT双能量扫描肝脏肿瘤诊断应用价值.方法分析已做双能CT检查经病理证实或符合临床诊断标准20例肝脏肿瘤患者(原发性肝癌8例,胆管细胞癌3例,肝脏海绵状血管瘤5例,转移性肝癌4例),双能量门静脉期扫描后自动生成3个序列图像:80、140、120kV加权图像,将数据传输至工作站(syngo MMWP VE36A),用Dual Energy中软件,选中Liver VNC生成虚拟平扫(VNC)图像,分析普通平扫(TNE)与VNC肿瘤显示情况,并进行能谱分析、碘含量测定.结果 VNC均能显示TNE中肿瘤,常规平扫TNE肝脏、脾脏、腹主动脉、脊柱后方肌肉的CT值(HU)分别为:(57.72±5.61),(48.52±3.43),(44.65±7.52),(56.41±3.48);虚拟平扫VNC上述CT值(HU)分别为,(58.24±5.24),(49.46±5.38),(45.61±3.71),(57±6.15),上述相同脏器CT值进行t检验后(分别为t=1.354,t=1.563,t=1.647,t=1.821,P>0.05),差异无统计学意义.原发性肝癌与胆管细胞癌和肝海绵状血管瘤在实质期碘浓度、碘图比值分别为:(1.41±0.35)g/L、(0.51±0.15)g/L;(2.97±1.21)g/L、(0.95±0.28)g/L;(3.02±0.33)g/L、(0.83±0.27)g/L,原发性肝癌在实质期碘基图像上的二者数值分别低于肝血管瘤、胆管细胞癌,差异具有明显统计学意义(t=2.531、t=2.572,P<0.05).结论双源CT双能量扫描在肝脏肿瘤诊断中具有潜在的临床应用价值.  相似文献   

6.
目的通过实验分析水模体的CT图像数据,探讨层面位置对西门子CT模拟机图像噪声的影响。方法调用西门子Sensation Open CT模拟机的日常质量检测程序,使用水模体进行10次测量,得到两种情形(标称管电压120 kV和140 kV)相邻的六层(S1~S6)CT图像。通过手工勾画得到感兴趣区CT值的标准偏差值(图像噪声)数据。对不同层面位置的图像噪声数据进行统计分析和比较研究。结果120 kV情形下,S1~S6层的图像噪声分别为(10.73±0.05)、(10.66±0.05)、(10.58±0.09)、(10.58±0.08)、(10.72±0.06)、(10.88±0.06)HU;140 kV情形下,S1~S6层的图像噪声分别为(10.09±0.09)、(10.02±0.04)、(9.90±0.07)、(9.93±0.05)、(10.1±0.09)、(10.17±0.12)HU。统计分析显示,不同层面的图像噪声数据总体上有统计学差异。结论层面位置对西门子CT模拟机图像噪声有影响,中心层面位置的图像噪声小于两端层面的数值。  相似文献   

7.
目的 评价双层探测器光谱CT(DL-SDCT)虚拟单能量图像(VMI)和碘图在肾脏实性肿瘤诊断中的应用价值。方法 回顾性分析77例肾脏实性肿瘤增强CT影像资料,获得皮髓质交界期常规CT图像、VMI、碘图和VMI-碘图融合图,测量各组图像中肿瘤、肌肉和肾皮质的CT值、碘密度值(ID)和图像噪声值,计算对比噪声比(CNR)、相对强化值(REV)和标准化碘密度(NID)。采用5分法分别评价图像质量。结果 相比于常规图像,VMI图像噪声值更低,且CNR值更高(P均<0.001)。VMI-碘图融合图的主观评分最高。DL-SDCT定量参数REV及NID均可用于透明细胞癌的诊断。结论 DL-SDCT的VMI、碘图及其融合图的图像质量优于常规CT,有助于肾脏实性肿瘤的细节显示和定性诊断。  相似文献   

8.
目的 探讨双源CT 80 kV低管电压在冠状动脉CT血管成像(CCTA)中的可行性.方法 对2014年12月至2015年11月亳州市人民医院收治的行CCTA检查、体质指数(BMI)≤30 kg/m2的56例患者,按检查顺序分成A组(100 kV、碘克沙醇320 mgI/mL)及B组(80 kV、碘克沙醇320 mgI/mL),每组各28例.比较两组患者的辐射剂量;测量升主动脉(AO)根部的CT值及噪声(SD)、图像的信噪比(SNR);测量左冠状动脉主干(LM)、左冠状动脉前降支(LAD)近段、左冠状动脉回旋支(LCX)近段、右冠状动脉(RCA)近段的CT值及邻近组织的CT值,计算LM、LAD、LCX、RCA近段的对比度噪声比(CNR).采用Likert4分法对每组患者容积重组(VR)及最大密度投影重组(MIP)图像进行双盲主观分级评分,并作统计学分析.结果 A组辐射剂量(4.36 ±0.71) mSv高于B组(1.75 ±0.40)mSv,差异有统计学意义(P<0.05);B组AO、RCA、LM、LAD、LCX近段的CT值高于A组,差异有统计学意义(P<0.05).B组图像的噪声(47.17 ±7.76)HU较A组(29.73 ±4.21)HU大,差异有统计学意义(P<0.05);两组图像的SNR、LM、LAD、LCX、RCA近段的CNR差异均无统计学意义(P>0.05);两组图像质量主观评分、用于诊断的冠脉节段数比较,差异无统计学意义(P>0.05).结论 对于BMI≤30 kg/m2的患者,在80 kV低管电压条件下行CCTA,能明显降低患者X线辐射剂量,且图像质量能够满足临床诊断要求.  相似文献   

9.
目的双源双能量CT是近年来发展起来的新的成像技术,对于血管成像具有独到的优势。迄今国内尚未见有该方法在富血供肝肿瘤方面的应用研究。文中初步探讨动脉期双能量CT对富血供肝肿瘤的临床应用价值。方法对30患者行上腹部动脉期双能量CT扫描,同时获得140 kVp、80 kVp及两者按0.3比例融合的加权图像。分别测量3种图像的病变部位、邻近正常肝组织及腹部前壁均匀脂肪的密度,以病变肝组织与邻近正常肝组织的密度差表示病灶清晰度。计算3种图像的对比噪声比(contrast-to-noise ratio,CNR)。采用3分方法评价3种图像的图像质量。采用随机区组的秩和检验进行统计学分析,组间两两比较采用LSD检验。结果检出23例不同肝病患者,共34个病灶。3组病灶清晰度差异有统计学意义(P=0.001)。80 kVp的病灶清晰度[(33.15±15.6)HU]明显高于加权图像[(21.0±10.7)HU],P=0.011和140 kVp图像[(17.8±8.4)HU],P=0.002。3组对比噪声比差异有统计学意义(P=0.001),80 kVp的CNR(2.49±1.15)高于140 kVp(1.5±0.9),P=0.0...  相似文献   

10.
不同管电压下周围结构对CT值测量影响的研究   总被引:1,自引:0,他引:1  
目的:探讨不同管电压对CT值测量的影响及周围结构对CT值测量的影响.方法:CT扫描仪的管电压分别设定为120、100、80 kV,其它扫描参数不变,分别对4%碘对比剂、医用硅胶块、乳胶块、生物胶块及由这几种物质制备的类动脉硬化血管模型进行扫描,测量不同条件下各单一结构及模型中相应同种结构的CT值,评估不同管电压及周围结构对CT值测量的影响.结果:120 kV时碘对比剂、医用硅胶块、乳胶块、生物胶块及模型中4种物质的CT值分别为(380.63±8.49)HU和(377.03±3.83)HU(P=0.02)、(293.94±17.83)HU和(334.07±5.95)HU(P =0.00)、(-154.64±12.56)HU和(-95.09±26.22)HU(P=0.00)、(-54.66±2.09)HU和(-40.79±6.85)HU(P =0.00);100 kV时CT值分别为(442.97±6.48)HU和(439.77±4.95)HU(P =0.02)、(332.79±6.78)HU和(383.90±6.14)HU(P=0.00)、(-166.32±12.61)HU和(-122.43±27.71)HU(P =0.00)、(-74.28±4.41)HU和(-64.74±10.65)HU(P=0.00);80 kV时CT值分别为(557.74±5.61)HU和(556.80±9.70)HU(P =0.62)、(426.71±8.70)HU和(489.90±12.31) HU(P=0.00)、(-202.30±27.10)HU和(-139.57±26.77)HU(P=0.00)、(-87.64±4.77)HU和(-79.81± 14.64)HU(P =0.00).当管电压降低时,高密度物质CT值升高,低密度物质CT值降低.周围结构对CT值测量亦有影响,物质之间的密度差别越大,其CT值所受影响越大.结论:管电压改变时周围结构对碘对比剂的CT值影响不大,但对其他结构影响较大.在进行CT值的定量研究时要关注管电压的改变以及周围结构对CT值的影响.  相似文献   

11.
Objective To retrospectively determine the features of stones and calcifications in hepatobiliary system on virtual nonenhanced (VNE) dual-energy computed tomography (CT), and to evaluate the possibility of VNE images in diagnosis for those lesions. Methods A total of 128 gall stones and calcifications of the liver found in 110 patients were examined with triple phase abdominal CT scan from July 2007 to December 2011, in which true nonenhanced (TNE) phase and arterial phase were performed with single-energy CT (120 kVp) and portal venous phase was performed with dual-energy CT (100 kVp and 140 kVp). VNE images were generated from the portal venous phase dual-energy CT data sets by using commercially VNC software. The mean CT values for the stone, liver, bile and paraspinal muscle, mean lesion density and size in area dimension, contrast-to-noise ratio (CNR) of lesion to the liver or bile, and image noise were assessed and compared between VNE and TNE images. The effective dose and size-specific dose estimate (SSDE) were also calculated. Results The mean CT values of the lesions measured on VNE images declined significantly compared with those measured on TNE images (164.51±102.13vs. 290.72±197.80 HU,P<0.001), so did the lesion-to-liver CNR (10.80±11.82vs.18.81±17.06,P<0.001) and the lesion-to-bile CNR (17.24±14.41 vs. 21.32±17.31,P<0.001). There was no significant difference in size of lesions area between VNE and TNE images (0.69±0.88vs.0.72±0.85 cm2,P=0.062). Compared to the 128 lesions found in TNE images, VNE images showed the same density in 30 (23.4%) lesions, lighter density in 88 (68.8%) lesions, while failed to show 10 (7.8%) lesions, and showed the same size in 61 (47.7%) lesions and smaller size in 57 (44.5%) lesions. The CT cutoff values of lesion and size were 229.21 HU and 0.15 cm2, respectively. The total effective dose for triple phase scan protocol with TNE images was 19.51±7.03 mSv, and the SSDE was 39.84±11.10 mGy. The effective dose for dual phase scan protocol with VNE images instead of TNE images was 13.29±4.89 mSv, and the SSDE was 27.83±9.99 mGy. Compared with TNE images, the effective dose and SSDE of VNE images were down by 32.05%±3.69 % and 30.63%±2.34 %, respectively. Conclusions Although the CT values and CNR of the lesions decreased in VNE images, the lesions of which attenuation greater than 229.21 HU and size larger than 0.15 cm2could be detected with good reliability and obvious dose reduction. There was good consistency in the size of stones and calcifications in hepatobiliary system between VNE images and TNE images, which ensured the possibility of the clinical application of VNE images.  相似文献   

12.
目的 探讨正弦图确认迭代重建(SAFIRE)技术在胸部低剂量CT扫描中的应用价值.方法 随机选取亳州市人民医院2014年6月至2014年12月有前后2次胸部CT扫描记录的30例患者影像学资料,2次扫描分别为传统的滤波反投影重建(FBP)及SAFIRE技术,SAFIRE强度为Strenth3;统计比较每位患者2次扫描图像的CT值、噪声(SD)、信噪比(SNR)及有效辐射剂量(ED).结果 两组上肺部(胸大肌)、中肺部(升主动脉根部)及下肺部(椎旁软组织)的CT值分别为:FBP组为(51.19±6.22)HU、(42.87 ±7.37)HU、(45.84 ±8.37)HU;SAFIRE组为(53.91±12.89)HU、(42.55±8.20) HU、(44.43±15.47) HU;两组平扫SD分别为:FBP组为(8.65±2.07) HU、(9.19 ±1.69)HU、(13.27±3.05) HU,SAFIRE组为(18.41±18.00) HU、(19.20±15.71)HU、(29.24 ±30.09)HU;两组之间差异均无统计学意义(P>0.05);两组的SNR分别为:FBP组为6.31 ±1.87、4.82±1.06、3.73±1.36,SAFIRE组为4.39±2.20、3.03 ±1.33、2.45±1.43,两组之间差异有统计学意义(P<0.05);两组的ED值:FBP组为(2.84±0.88) mSv,SAFIRE组为(1.27±0.64) mSv,两组之间差异有统计学意义(P<0.05);两组图像主观评分差异无统计学意义(P>0.05).结论 与传统FBP重建技术相比,SAFIRE重建技术能够在保证图像质量不影响诊断的同时,有效地降低CT辐射剂量,从而保证患者的安全.  相似文献   

13.
目的 探讨双源CT双能量成像中Satire重建算法及FBP重建算法在高体质指数(BMI)患者冠状动脉检查中的应用,评价Satire算法改善图像质量的应用价值。方法 收集50例临床怀疑冠心病患者的双源CT双能量扫描资料,最终35例纳入研究,体质指数为(30.06±3.22)kg/m^2,通过重建得到常规FBP算法重建的100kV数据组、融合数据组(相当于120kV数据)和Satire算法重建的100kV数据组、融合数据组(相当于120kV数据),4组图像分别命名为FBP—A与FBP-B及Safire-A与Satire—B;由2名医师对35例共540个冠状动脉节段进行主观图像质量计分评价,应用Kappa检验分析其一致性;应用秩和检验对FBP组与Satire组相同能量间CNR与SNR对应比较及Satire组内两组能量的不同能量间CNR与SNR对应比较来进行客观图像质量的评价。结果 主观图像质量评分结果 具有良好一致性(Kappa值=0.801,P〈0.05),客观图像质量比较FBP—A与Safire-A组间存在统计学差异(P〈0.05);FBP—B与Safire-B组间存在统计学差异(P〈0.05),Safire—A、B组CNR、SNR均优于FBP—A、B组,Satire—A与Safire-B组间无统计学差异(P〉0.05);结论 Satire算法重建图像在双能量CT冠脉扫描中对高体质指数(BMI)的患者可明显降低图像噪声,提高图像质量。  相似文献   

14.
目的探讨宝石能谱CT单能量成像在显示乏血供肝癌病灶中的使用价值。方法运用宝石能谱CT对34例乏血供肝癌患者进行能谱扫描,对原始数据进行常规混合能量重建(140 kVp)和单能量重建(65 keV),在GE AW4.4工作站上通过能谱浏览器(GSI Viewer)分别选用混合能量图像和单能量图像对同层面病灶进行观察,观察病灶的数目、病灶与周边正常肝组织的对比(CT值差值)、背景噪声、对比噪声比和主观评分,并做配对t检验。结果在同一层面上单能图像发现的病灶数目明显多于混合能量图像。34例患者中仅有12例结果一致,22例单能图像显示病灶数目多于混合能量图像。单能与混合能图像中病灶与正常肝组织间的对比、对比噪声比及主观评分分别为(21.19±15.23)和(11.13±10.09)、(1.53±0.88)和(0.88±0.68)、(4.32±0.65)和(3.7±0.53),各项指标间的差异有统计学意义(P<0.01),图像背景噪声为(14.02±2.08)和(13.64±2.07),差异无统计学意义。结论宝石能谱CT GSI模式扫描重建65 keV单能图像可明显提高乏血供肝癌的检出率。  相似文献   

15.
目的 探讨低管电压结合自适应迭代剂量降低算法重建技术(AIDR)在优化婴幼儿胸部CT扫描方案中的应用价值.方法 回顾性分析笔者医院2013年1~5月间,从拟行胸部CT检查显示正常的,无贫血及其他疾病的0~1岁婴幼儿中随机选取40例,平均分成A与B两组,A组扫描时管电压为80kV,使用适应迭代剂量降低算法重建技术(AIDR);B组为100kV,使用常规滤波反投影(FBP)重建技术.比较两组间气管分杈层面降主动脉的CT值与标准差(SD)、信噪比(SNR)、对比信噪比(CNR)、CT剂量指数(CTDI)及剂量长度乘积(DLP).结果 两组的图像质量评分分别为4.56±0.48、4.61±0.45,差异无统计学意义(P>0.05).两组CT值、SD分别为50.36±5.74HU、12.57±4.48和45.31±4.71HU、10.61±3.48,A组高于B组,差异均无统计学意义(P>0.05).两组SNR和CNR分别为3.31±1.02、2.68±1.21和4.31±1.32、2.74±0.92,B组均高于A组,两组相比无统计学差异(P>0.05).两组的有效辐射剂量分别为1.79±0.316、5.04±0.19mSv,A组较B组辐射剂量明显降低,平均减少了65%.结论 320层CT在小儿胸部扫描采用80kV管电压扫描加ADIR重建,图像质量能达到诊断要求,且辐射剂量可显著降低.  相似文献   

16.
目的探讨80k V低管电压多层螺旋CT血管成像(CTA)对颈动脉斑块的临床应用价值。方法对56例患者在一周内行颈动脉低管电压(80k V)CTA和彩色多普勒血流显像(CDFI)检查。记录MSCTA中每例患者的容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP),计算出有效剂量(ED),并记录颈总动脉、分叉处、颈内动脉CT值,算出均值;分析比较两种检查方法对颈动脉斑块的检出率、斑块性质及狭窄程度的差异。结果 CTA的CTDIvol、DLP、ED分别为(11.82±0.00)m Gy、(295.04±43.93)m Gy.cm、(1.74±0.26)m Sv;颈动脉CT均值为(489.71±46.74)HU;低管电压CTA及CDFI对颈动脉斑块的检出、斑块性质判定、狭窄程度的判定结果差异无统计学意义(K0.60,P0.05)。结论采用80k V低管电压行颈部CTA检查,受检者的辐射剂量明显降低,且对颈动脉斑块的诊断不受影响,是一种行之有效的低剂量扫描方法。  相似文献   

17.
目的探讨第二代双源CT虚拟平扫技术在肺部病变中的应用价值。方法回顾性分析58例经病理证实肺部病变患者的影像资料,均行常规平扫及双能量增强扫描,利用"Liver VNC"软件处理得到虚拟平扫图像。比较虚拟平扫与常规平扫图像质量评分、噪声、病灶平均CT值及辐射剂量。结果虚拟平扫与常规平扫图像质量评分分别为(4.62±0.52)、(4.71±0.46)分,两者无明显差异t=2.319,P>0.05;虚拟平扫图像和常规平扫图像噪声分别为(8.10±1.16)、(7.30±1.06)HU,虚拟平扫噪声略高于常规平扫t=5.246,P<0.05;虚拟平扫与常规平扫病变CT值分别为(32.65±8.09)、(27.94±7.16)HU,t=-8.154,P<0.05;且两组CT值有很好的一致性(r=0.840,P<0.05)。虚拟平扫与常规平扫的有效剂量分别为(5.18±0.96)、(5.55±1.18)mSv,虚拟平扫有效剂量低于常规平扫t=4.005,P<0.05。结论虚拟平扫图像对肺部病变显示良好,可满足诊断要求,有代替胸部常规平扫潜在价值,减少检查时间及患者的辐射剂量。  相似文献   

18.
目的对比研究双源CT小肠造影双能量虚拟平扫与常规平扫图像,探讨虚拟平扫临床应用的可行性。方法采用第三代双源CT对42例患者进行小肠造影检查,行常规CT平扫及动、静脉期对比增强双能量扫描(100 kV和sn150 kV)。利用肝脏VNC软件进行后处理,获得动、静脉期虚拟平扫CT图像。选择基本相同的层面测定常规CT平扫及动、静脉期虚拟平扫正常回肠壁及竖脊肌的CT值和噪声并计算信噪比、对比噪声比;采用5级(0~4分)标准评价三者的图像质量并比较病变检出情况;记录辐射剂量。结果常规平扫和动、静脉期虚拟平扫正常回肠壁及竖脊肌的CT值、SNR、CNR及图像质量评分无统计学差异(P>0.05),虚拟平扫可以显示常规平扫所有病变。常规平扫和动、静脉期增强双能量CT扫描有效辐射剂量分别为(6.23±1.79)、(5.35±1.39)、(5.33±1.37)mSv,常规CT平扫有效辐射剂量高于动、静脉期增强双能量CT扫描(P<0.05),动静脉增强扫描之间差异无统计学意义(P>0.05)。结论双源CT双能量小肠造影虚拟平扫成像有可能代替传统常规平扫,降低患者接受的辐射剂量。  相似文献   