首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This article aims to clarify the influence of design‐ and manufacturing‐related parameters on wear of metal‐on‐metal (MoM) joint bearings. A database search for publications on wear simulator studies of MoM bearings was performed. The results of published studies were normalized; groups with individual parameters were defined and analyzed statistically. Fifty‐six investigations studying a total of 200 implants were included in the analysis. Clearance, head size, carbon content, and manufacturing method were analyzed as parameters influencing MoM wear. This meta‐analysis revealed a strong influence of clearance on running‐in wear for implants of 36‐mm diameter and an increase in steady‐state wear of heat treated components. © 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 27:1473–1480, 2009  相似文献   

2.
3.
BackgroundAdverse reactions to metal debris (ARMD) have been a problem with metal-on-metal (MoM) hip systems for a decade. Unacceptably high revision rates have been described for both stemmed MoM total hip arthroplasties (THAs) and hip resurfacings. The aim of this study was to report survivorship and temporal trends of hip revisions in patients with MoM hips.MethodsWe identified 2520 patients with 3013 MoM hip arthroplasties performed at our institution. These included 1532 primary stemmed MoM THAs, 1262 MoM hip resurfacings, and 219 stemmed MoM THAs implanted in revision surgery.ResultsRevision surgery was performed on 551 (36%) primary stemmed MoM THAs and on 179 (14%) resurfacings. The most common reason for revision was ARMD both among primary MoM THAs (83%) and hip resurfacings (70%). The 15-year implant survivorship was 69% (95% confidence interval [CI] 67-71%) for the whole study group, 56% (CI 53-60%) for stemmed primary MoM THAs, and 84% (CI 82-87%) for hip resurfacings. Clear temporal peak in the number of revisions for ARMD was seen in 2011-2013, and the trend has been decreasing since.ConclusionAfter a decade since outburst of the ARMD problematics with MoM hips, a large proportion of them have gone through revision surgery at our single high-volume center. The peak years were 2011-2013, and thereafter, the number of ARMD revisions has decreased every year. With the threshold for revision remaining constant at our institution, it is not likely that large amount of new cases of ARMD will be seen. As these results are derived from a single center's data, similar studies from other institutions are needed to see whether our results represent a global trend.  相似文献   

4.
We present a retrospective evaluation of 1369 hip arthroplasties performed using the Bicon-Plus cups and SL-Plus stems, differing only in the bearing combination. Four bearing combination groups were used: metal-on-polyethylene (MoP) group with 587 hips, ceramic-on-polyethylene (CoP) group with 161 hips, metal-on-metal (MoM) group with 322 hips and ceramic-on-ceramic (CoC) group with 299 hips. The mean follow-up was 11.5 years (4.1 to 15.0). Radiological evaluation was performed on implants failed due to aseptic loosening. The survival for prosthesis with revision for any reason at ten years was 96.1% (95% confidence interval (CI) 94.3 to 97.9) for MoP, 98.1% (CI 95.9 to 100) for CoP, 90.2% (CI 86.8 to 93.6) for MoM, and 95.6% (CI 93.0 to 98.2) for CoC. Survival for aseptic loosening was also determined.  相似文献   

5.

Background

Dislocation is a major complication after primary total hip arthroplasty (THA), but little is known about the potential relationships between bearing materials and risk of dislocation. Dislocation within the first year after surgery is typically related to either surgical error or patient inattention to precautions, but the reasons for dislocation after the first year are often unclear, and whether ceramic bearings are associated with an increased or decreased likelihood of late dislocation is controversial.

Questions/purposes

The purpose of this study was to use a national registry to assess whether the choice of bearings–metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), ceramic-on-ceramic (CoC), or metal-on-metal (MoM)–is associated with differences in the risk of late dislocation.

Methods

Data from primary THAs were extracted from the New Zealand Joint Registry over a 10-year period. The mean age of patients was 69 years (SD ± 12 years), and 53% were women. The median followup in this population was 7 years (range, 1–13 years). The surgical approach used was posterior in 66% of THAs, lateral in 29%, and anterior in 5%. The primary endpoint was late revision for dislocation with “late” defined as greater than 1 year postoperatively. A total of 73,386 hips were available for analysis: 65% MoP, 17% CoP, 10% CoC, and 7% MoM. In general, patients receiving CoC and MoM bearings were younger compared with patients receiving CoP and MoP bearings.

Results

Four percent of the hips were revised (3130 THAs); 867 THAs were revised for dislocation. Four hundred seventy THAs were revised for dislocation after the first postoperative year. After adjusting for head size, age, and surgical approach, only CoP (hazard ratio [HR], 2.10; p = 0.021) demonstrated a higher proportion of revision, whereas MoP did not (HR, 1.76; 95% p = 0.075). There were no differences of revisions for dislocation in the CoC (HR, 1.60; p = 0.092) and MoM cohorts (HR, 1.54; p = 0.081).

Conclusions

Dislocation is a common reason for revision after THA. The relationships between bearing materials and risk of revision for late dislocation remain controversial. This large registry study demonstrated that bearing surface had little association with the incidence of late dislocation. Future studies with longer followups should continue to investigate this question.

Level of Evidence

Level III, therapeutic study.  相似文献   

6.
BackgroundLong-term survival of metal-on-metal (MoM) prostheses and the development of adverse reaction to metal debris (ARMD) around these bearings are still unclear. Serum levels of cobalt (Co) and chromium (Cr) are used as a screening tool to anticipate failure in MoM bearings and detect ARMD.MethodsOne hundred sixty primary large head MoM prostheses were followed up for 10 years. To estimate the revision risk, the cumulative incidence function (CIF) was used. Subdistribution hazard modeling was used to investigate the associations between cumulative incidence of revision for ARMD and Co levels, Cr levels, gender, age, head size, and cup inclination. Furthermore, the safe upper limits (SULs) for Co and Cr were determined.ResultsUnivariate analyses showed an increased risk in revision for ARMD in females (subdistribution hazard ratio [sdHR] 3.43, 95% confidence interval [CI] 1.01-11.7, P = .049) and cup inclination angles over 45° (sdHR 4.70, 95% CI 1.63-13.58, P = .004). In addition, a higher last measured Co level (sdHR 1.05, 95% CI 1.03-1.07, P < .001) and last measured Cr level (sdHR 1.21, 95% CI 1.14-1.29, P < .001) were associated with a higher probability of revision for ARMD. We determined our bearing-specific SULs at 4.1 parts per billion (ppb) and 4.2 ppb for Co and Cr, respectively.ConclusionGuidelines regarding follow-up and surveillance should include a complete clinical assessment with bearing-specific SULs of serum metal ion levels. For the M2a-Magnum MoM bearing we advise an SUL for Co and Cr levels of 4.1 and 4.2 ppb, respectively.  相似文献   

7.

Background

Bearing surface issues related to trunnionosis or metal-on-metal (MoM) articulations have likely impacted recent trends in bearing surface choice. The purpose of this study is to evaluate trends in total hip arthroplasty (THA) bearing surface use, including 2015 data, with respect to the date of operation and patient demographics.

Methods

The Humana dataset was reviewed from 2007 through 2015 to analyze bearing surface usage in primary THA. Four bearing surface types were identified by International Classification of Disease, 10th Revision codes and trended throughout the years: metal-on-polyethylene (MoP), ceramic-on-ceramic (CoC), ceramic-on-polyethylene (CoP), and MoM. Prevalence was analyzed as a function of age and sex.

Results

Of the 28,504 primary THA procedures, the most commonly used bearing was MoP (46.1%), followed by CoP (33.2%), MoM (17.1%), and ceramic-on-ceramic (3.6%). The use of CoP bearings significantly increased from 6.4% in 2007 to 52.0% in 2015, while MoM bearings decreased during this period. MoP bearings decreased over 2012-2015 (P < .001). CoP usage decreased with age, while MoP bearings increased with a transition occurring at 65-69 years of age. Women were more likely to receive MoP bearings (odds ratio [OR] 1.2), while men were more likely to receive MoM and CoP bearings (OR 1.1). Multivariate logistic regression showed age to be an independent predictor of bearing surface choice with patients 65 and older more likely to receive MoP bearings (OR 3.2).

Conclusion

Bearing surface choice in primary THA has changed tremendously from 2007 to 2015. MoM bearing use has decreased as a result of adverse effects. Age continues to remain a significant factor in bearing surface choice.  相似文献   

8.
Metal-on-metal (MoM) bearings for total hip arthroplasty (THA) have come under scrutiny with reports of high failure rates. Clinical outcome studies with several commercially available MoM THA bearings remain unreported. We evaluated 78 consecutive MoM THAs from a single manufacturer in 68 patients. Sixty-six received cobalt–chrome (CoCr) monoblock and 12 received modular titanium acetabular cups with internal CoCr liners. Femoral components were titanium with modular necks. At average 2.1 years postoperatively, 12 THAs (15.4%) demonstrated aseptic failure (10 revisions, 2 revision recommended). All revised hips demonstrated capsular necrosis with positive histology reaction for aseptic lymphocytic vasculitis-associated lesions/adverse local tissue reactions. Prosthetic instability following revision surgery was relatively common. Female gender was a strong risk factor for failure, though smaller cups were not. Both monoblock and modular components fared poorly. Corrosion was frequently observed around the proximal and distal end of the modular femoral necks.  相似文献   

9.
Metal‐on‐metal (MoM) bearings are at the forefront in hip resurfacing arthroplasty. Because of their good wear characteristics and design flexibility, MoM bearings are gaining wider acceptance with market share reaching nearly 10% worldwide. However, concerns remain regarding potential detrimental effects of metal particulates and ion release. Growing evidence is emerging that the local cell response is related to the amount of debris generated by these bearing couples. Thus, an urgent clinical need exists to delineate the mechanisms of debris generation to further reduce wear and its adverse effects. In this study, we investigated the microstructural and chemical composition of the tribochemical reaction layers forming at the contacting surfaces of metallic bearings during sliding motion. Using X‐ray photoelectron spectroscopy and transmission electron microscopy with coupled energy dispersive X‐ray and electron energy loss spectroscopy, we found that the tribolayers are nanocrystalline in structure, and that they incorporate organic material stemming from the synovial fluid. This process, which has been termed “mechanical mixing,” changes the bearing surface of the uppermost 50 to 200 nm from pure metallic to an organic composite material. It hinders direct metal contact (thus preventing adhesion) and limits wear. This novel finding of a mechanically mixed zone of nanocrystalline metal and organic constituents provides the basis for understanding particle release and may help in identifying new strategies to reduce MoM wear. © 2009 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 28:436–443, 2010  相似文献   

10.
《The Journal of arthroplasty》2022,37(10):2053-2062
BackgroundDifferent bearings have been used in total hip arthroplasty (THA), but the long-term performance is still controversial. The purpose of this study was to investigate whether there are differences when comparing THAs with 5 different bearings at a long-term follow-up of more than 10 years.MethodsFrom January 2010 to May 2012, 101 THA patients (134 hips) were divided into metal-on-metal group (MoM, 31 hips), metal-on-polyethylene group (MoP, 23 hips), ceramic-on-metal group (CoM, 21 hips), ceramic-on-ceramic group (CoC, 33 hips), and ceramic-on-polyethylene group (CoP, 26 hips). The mean follow-up period was 10.3 years. The Harris hip score (HSS), Western Ontario and McMaster Universities Osteoarthritis Index scores (WOMAC), range of motion (ROM), blood cell count, and liver-kidney function were measured. Serum and urine metal ion levels were measured using high-resolution inductively coupled plasma-mass spectrometry (ICP-MS) and a blood lymphocytes analysis was counted by flow cytometry.ResultsNo difference was observed in the HSS, WOMAC, ROM, blood cell count, or liver-kidney function among any of the 5 groups. Metal ion levels were significantly elevated in metal-containing bearings. Flow cytometry showed that no differences were found. Revision was performed due to pseudotumor in 3 patients. The implant survival rate was 96.7% and 93.3% for the MoM and CoC groups, which was significantly lower compared with other groups.ConclusionsMetal ion levels were elevated significantly in metal-containing bearings, especially in MoM THA patients. The implant survival rate was significantly lower in CoC and MoM THAs, which was mainly due to pseudotumor formation.Level of EvidenceTherapeutic Level II.  相似文献   

11.
Some tissues from metal‐on‐metal (MoM) hip arthroplasty revisions have shown evidence of adaptive‐immune reactivity (i.e., excessive peri‐implant lymphocyte infiltration/activation). We hypothesized that, prior to symptoms, some people with MoM hip arthroplasty will develop quantifiable metal‐induced lymphocyte reactivity responses related to peripheral metal ion levels. We tested three cohorts (Group 1: n = 21 prospective longitudinal MoM hip arthroplasty; Group 2: n = 17 retrospective MoM hip arthroplasty; and Group 3: n = 20 controls without implants). We compared implant position, metal‐ion release, and immuno‐reactivity. MoM cohorts had elevated (p < 0.01) amounts of serum Co and Cr compared to controls as early as 3 months post‐op (Group 1:1.2 ppb Co, 1.5 ppb Cr; Group 2: 3.4 ppb Co, 5.4 ppb Cr; Group 3: 0.01 ppb Co, 0.1 ppb Cr). However, only after 1–4 years post‐op did 56% of Group 1 develop metal‐reactivity (vs. 5% pre‐op, metal‐LTT, SI > 2), compared with 76% of Group 2, and 15% of Group 3 controls (patch testing was a poor diagnostic indicator with only 1/21 Group 1 positive). Higher cup‐abduction angles (50° vs. 40°) in Group 1 were associated with higher serum Cr (p < 0.07). However, sub‐optimal cup‐anteversion angles (9° vs. 20°) had higher serum Co (p < 0.08). Serum Cr and Co were significantly elevated in reactive versus non‐reactive Group‐1 participants (p < 0.04). CD4+CD69+ T‐helper lymphocytes (but not CD8+) and IL‐1β, IL‐12, and IL‐6 cytokines were all significantly elevated in metal‐reactive versus non‐reactive Group 1 participants. Our results showed that lymphocyte reactivity to metals can develop within the first 1–4 years after MoM arthroplasty in asymptomatic patients and lags increases in metal ion levels. This increased metal reactivity was more prevalent in those individuals with extreme cup angles and higher amounts of circulating metal. © 2012 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31: 173–182, 2013  相似文献   

12.
Alternative bearing surfaces for total hip arthroplasty, such as metal‐on‐metal and ceramic‐on‐ceramic, offer the potential to reduce mechanical wear and osteolysis. In the short and medium term, the second generation of metal‐on‐metal bearings demonstrated high systemic metal ion levels, whereas ceramic‐on‐ceramic bearings showed the lowest ones. We aimed to verify whether the long‐term ion release in metal‐on‐metal subjects was still relevant at a median 10‐year follow‐up, and whether a fretting process at the modular junctions occurred in ceramic‐on‐ceramic patients and induced an ion dissemination. Serum levels were measured in 32 patients with alumina‐on‐alumina implants (group A), in 16 subjects with metal‐on‐metal implants (group B), and in 47 healthy subjects (group C). Group B results were compared with medium‐term findings. Cobalt and chromium levels were significantly higher in metal‐on‐metal implants than in ceramic‐on‐ceramic ones and controls. Nevertheless, ion levels showed a tendency to decrease in comparison with medium‐term content. In ceramic‐on‐ceramic implants, ion values were not significantly different from controls. Both in groups A and B, aluminum and titanium release were not significantly different from controls. In conclusion, negligible serum metal ion content was revealed in ceramic‐on‐ceramic patients. On the contrary, due to the higher ion release, metal‐on‐metal coupling must be prudently considered, especially in young patients, in order to obtain definitive conclusions. © 2008 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res  相似文献   

13.
Taper wear at the head‐neck junction is a possible cause of early failure in large head metal‐on‐metal (LH‐MoM) hip replacements. We hypothesized that: (i) taper wear may be more pronounced in certain product designs; and (ii) an increased abductor moment arm may be protective. The tapers of 104 explanted LH‐MoM hip replacements revised for adverse reaction to metal debris (ARMD) from a single manufacturer were analyzed for linear and volumetric wear using a co‐ordinate measuring machine. The mated stem was a shorter 12/14, threaded trunnion (n = 72) or a longer, smooth 11/13 trunnion (n = 32). The abductor moment arm was calculated from pre‐revision radiographs. Independent predictors of linear and volumetric wear included taper angle, stem type, and the horizontal moment arm. Tapers mated with the threaded 12/14 trunnion had significantly higher rates of volumetric wear (0.402 mm3/yr vs. 0.123 mm3/yr [t = ?2.145, p = 0.035]). There was a trend to larger abductor moment arms being protective (p = 0.055). Design variation appears to play an important role in taper‐trunnion junction failure. We recommend that surgeons bear these findings in mind when considering the use of a short, threaded trunnion with a cobalt‐chromium head. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:1868–1874, 2015.
  相似文献   

14.
Background and purpose — It is unclear whether metal particles and ions produced by mechanical wear and corrosion of hip prostheses with metal-on-metal (MoM) bearings have systemic adverse effects on health. We compared the risk of heart failure in patients with conventional MoM total hip arthroplasty (THA) and in those with metal-on-polyethylene (MoP) THA.

Patients and methods — We conducted a retrospective cohort study using data from the Australian Government Department of Veterans’ Affairs health claims database on patients who received conventional THA for osteoarthritis between 2004 and 2012. The MoM THAs were classified into groups: Articular Surface Replacement (ASR) XL Acetabular System, other large-head (LH) (> 32?mm) MoM, and small-head (SH) (≤ 32?mm) MoM. The primary outcome was hospitalization for heart failure after THA.

Results — 4,019 patients with no history of heart failure were included (56% women). Men with an ASR XL THA had a higher rate of hospitalization for heart failure than men with MoP THA (hazard ratio (HR)?=?3.2, 95% CI: 1.6–6.5). No statistically significant difference in the rate of heart failure was found with the other LH MoM or SH MoM compared to MoP in men. There was no statistically significant difference in heart failure rate between exposure groups in women.

Interpretation — An association between ASR XL and hospitalization for heart failure was found in men. While causality between ASR XL and heart failure could not be established in this study, it highlights an urgent need for further studies to investigate the possibility of systemic effects associated with MoM THA.  相似文献   

15.
Purpose: The widespread usage of metal‐on‐metal (MoM) articulations in total hip arthroplasty (THA) has been tempered by concerns of increased metal ion production. The purpose of the study is to evaluate the influence of metal ion exposure on semen quality in young male patients undergoing THA. Methods: Male patients who were scheduled for unilateral THA and aged between 20 and 45 years were prospectively enrolled. Patients were sorted into MoM and metal‐on‐polyethylene (MoP) groups with equal case number. Semen and blood metal ion levels were measured and sperm analysis was performed before, 6 months after, and 1 year after surgery. Results: Compared to preoperative baseline, patients (n = 50) in both groups had increased cobalt (Co) and chromium (Cr) concentrations in blood and seminal fluid after surgery. Between‐group comparisons at 6 months and 1 year after surgery showed that patients in the MoM group both had a greater Co concentration in blood and semen and a greater Cr concentration in blood and semen. Patients receiving MoM prosthesis had a reduced percentage of morphologically normal sperm, and decreases from the preoperative level (44.7%) were significant at 6 months (36.8%, p = 0.03) and 1 year (33.8%, p = 0.004). Conclusions: Our data shows a significantly greater concentration of metal ion in blood and semen in patients with MoM prosthesis with a reduced percentage of morphologically normal sperm. Despite small effects on sperm quality, some concerns remain. Further studies are necessary to determine sources of metal ion and to investigate effects on male fertility. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:544–551, 2016.  相似文献   

16.

Background

The use of metal-on-metal (MoM) hip bearings has declined in the recent years due to strong evidence of their high complication rates and early failure. Hip implants with highly cross-linked polyethylene liners and ceramic bearings have become the modern implants of choice. We sought to determine if MoM implants are associated with higher complication and revision rates when compared to other hip bearings in the Medicare population.

Methods

We retrospectively reviewed a Medicare database (2005-2011) for patients who underwent a primary total hip arthroplasty with a MoM, metal-on-polyethylene (MoP), ceramic-on-polyethylene (CoP), or ceramic-on-ceramic (CoC) implant (minimum 2 years of follow-up). Patient comorbidities and medical/surgical complication rates were analyzed at various time points postoperatively.

Results

We identified 288,118 patients, including 81,520 patients with a MoM implant, 162,881 with MoP, 33,819 with CoP, and 9898 with CoC implant. Surgical complication rates were higher for MoM implants including infection, osteolysis/polywear, mechanical complications, and need for hip irrigation and debridement. Overall revision rates were significantly higher for MoM implants (5.28%) compared to MoP (4.28%, odds ratio [OR] 1.26, P < .001) and CoP (3.52%, OR 1.55, P < .001) but only by one to two percent. MoM revision rates were similar to CoC implants (4.94%, OR 1.00, P = .096).

Conclusions

MoM implants were associated with higher revision rates (5.28%) compared to MoP (4.28%) and CoP (3.52%) implants in the Medicare population. Both complication and revision rates were comparable to CoC implants.  相似文献   

17.

Background and purpose

Data from the national joint registries in Australia and England and Wales have revealed inferior medium-term survivorship for metal-on-metal (MoM) total hip arthroplasty (THA) than for metal-on-polyethylene (MoP) THA. Based on data from the Nordic Arthroplasty Register Association (NARA), we compared the revision risk of cementless stemmed THA with MoM and MoP bearings and we also compared MoM THA to each other.

Patients and methods

We identified 32,678 patients who were operated from 2002 through 2010 with cementless stemmed THA with either MoM bearings (11,567 patients, 35%) or MoP bearings (21,111 patients, 65%). The patients were followed until revision, death, emigration, or the end of the study period (December 31, 2011), and median follow-up was 3.6 (interquartile range (IQR): 2.4–4.8) years for MoM bearings and 3.4 (IQR: 2.0–5.8) years for MoP bearings. Multivariable regression in the presence of competing risk of death was used to assess the relative risk (RR) of revision for any reason (with 95% confidence interval (CI)).

Results

The cumulative incidence of revision at 8 years of follow-up was 7.0% (CI: 6.0–8.1) for MoM bearings and 5.1% (CI: 4.7–5.6) for MoP bearings. At 6 years of follow-up, the RR of revision for any reason was 1.5 (CI: 1.3–1.7) for MoM bearings compared to MoP bearings. The RR of revision for any reason was higher for the ASR (adjusted RR = 6.4, CI: 5.0–8.1), the Conserve Plus (adjusted RR = 1.7, CI: 1.1–2.5) and “other” acetabular components (adjusted RR = 2.4, CI: 1.5–3.9) than for MoP THA at 6 years of follow-up.

Interpretation

At medium-term follow-up, the survivorship for cementless stemmed MoM THA was inferior to that for MoP THA, and metal-related problems may cause higher revision rates for MoM bearings with longer follow-up.Wear particles from the polyethylene liner in metal-on-polyethylene (MoP) bearings in total hip arthroplasty (THA) are associated with osteolysis and aseptic loosening of the implant (Jacobs et al. 1994). Surgeons therefore became interested in alternatives such as metal-on-metal (MoM) bearings. The main justification for using large-diameter-head (LDH) MoM bearings in THA was less wear and the hope of lower revision rates. However, a lower risk of revision has only been found for revision due to dislocation (Kostensalo et al. 2013), whereas the total risk of revision has been found to be increased in some studies (Smith et al. 2012, Huang et al. 2013). In addition, LDH MoM was introduced in order to achieve increased range of motion and better function (Burroughs et al. 2005, Davis et al. 2007), but that has not been shown clinically (Penny et al. 2013).Several concerns about the use of MoM bearings in hip surgery have been voiced in recent years: excessive failure rates for certain brands and implant combinations used with MoM components have been reported (Langton et al. 2011, Australian Orthopaedic Association 2013). Some designs are associated with increased frequency of aseptic loosening (Australian Orthopaedic Association 2013), and large head sizes placed on conventional stems may cause taper junction failure (Langton et al. 2012). Exposure to chromium and cobalt may cause adverse reactions to metal debris (ARMD) (Langton et al. 2010) such as pseudotumors (Pandit et al. 2008) and hypersensivity reactions (Willert et al. 2005) locally in the hip joint. Furthermore, metal ions may be genotoxic (Daley et al. 2004).Only a few population-based studies on MoM bearings in stemmed THAs from hip arthroplasty registries have been published (Smith et al. 2012, Mokka et al. 2013b, Furnes et al. 2014), with only 1 population-based study focusing on causes of revision resulting from specific combinations of acetabular and femoral components (Mokka et al. 2013b). We compared the 6-year revision risk for MoM bearings with that for MoP bearings in cementless stemmed THA. In addition, we studied different designs of stemmed MoM THAs and the causes of revision in a population-based follow-up study using data from the Nordic Arthroplasty Register Association (NARA).  相似文献   

18.
Background and purpose — Ceramic-on-ceramic (CoC) bearings were introduced in total hip arthroplasty (THA) to reduce problems related to polyethylene wear. We compared the 9-year revision risk for cementless CoC THA and for cementless metal-on-polyethylene (MoP) THA.

Patients and methods — In this prospective, population-based study from the Danish Hip Arthroplasty Registry, we identified all the primary cementless THAs that had been performed from 2002 through 2009 (n = 25,656). Of these, 1,773 THAs with CoC bearings and 9,323 THAs with MoP bearings were included in the study. To estimate the relative risk (RR) of revision, we used regression with the pseudo-value approach and treated death as a competing risk.

Results — 444 revisions were identified: 4.0% for CoC THA (71 of 1,773) and 4.0% for MoP THA (373 of 9,323). No statistically significant difference in the risk of revision for any reason was found for CoC and MoP bearings after 9 years of follow-up (adjusted RR = 1.3, 95% CI: 0.72–2.4). Revision rates due to component failure were 0.5% (n = 8) for CoC bearings and 0.1% (n = 6) for MoP bearings (p < 0.001). 6 patients with CoC bearings (0.34%) underwent revision due to ceramic fracture.

Interpretation — When compared to the “standard” MoP bearings, CoC THA had a 33% higher (though not statistically significantly higher) risk of revision for any reason at 9 years.  相似文献   

19.
Background and purpose — Large metal-on-metal (MoM) articulations are associated with metal wear and corrosion, leading to increased metal ion concentrations and unacceptable revision rates. There are few comparative studies of 28-mm MoM articulations with conventional metal-on-polyethylene (MoP) couplings. We present a long-term follow-up of a randomized controlled trial comparing MoM versus MoP 28-mm articulations, focused on metal ions and implant survival.

Patients and methods — 85 patients with a mean age of 65 years at surgery were randomized to a MoM (Metasul) or a MoP (Protasul) bearing. After 16 years, 38 patients had died and 4 had undergone revision surgery. 13 patients were unavailable for clinical follow-up, leaving 30 patients (n = 14 MoM and n = 16 MoP) for analysis of metal ion concentrations and clinical outcome.

Results — 15-year implant survival was similar in both groups (MoM 96% [95% CI 88–100] versus MoP 97% [95% CI 91–100]). The mean serum cobalt concentration was 4-fold higher in the MoM (1.5?μg/L) compared with the MoP cohort (0.4?μg/L, p < 0.001) and the mean chromium concentration was double in the MoM (2.2?μg/L) compared with the MoP cohort (1.0?μg/L, p = 0.05). Mean creatinine levels were similar in both groups (MoM 93?μmol/L versus MoP 92?μmol/L). Harris hip scores differed only marginally between the MoM and MoP cohorts.

Interpretation — This is the longest follow-up of a randomized trial on 28-mm MoM articulations, and although implant survival in the 2 groups was similar, metal ion concentrations remained elevated in the MoM cohort even in the long term.  相似文献   

20.
While favorable tribological properties and allowance for larger femoral head sizes have made metal‐on‐metal (MoM) bearings an increasingly popular choice for total hip arthroplasty, concerns have mounted regarding adverse reactions to metal wear debris and ions. MoM cups differ from conventional polyethylene cups in terms of edge profile design and reductions from full hemisphericity, suggesting differences in loading at or near the cup edge, especially during subluxation events. Finite element analysis was used to investigate the effects of cup orientation and lip edge curvature on damage propensity for edge or near‐edge loading during subluxation. Increased cup lip radius (resulting in reduced articular arc) had a detrimental effect upon subluxation‐free hip range of motion and upon dislocation resistance. Contact stresses near the cup edge demonstrated complex relationships between edge radius and cup orientation, with peak stresses being influenced by both variables. The tendency for scraping wear at the egress site demonstrated similarly complex dependencies. These data indicate that acetabular cup design is an important determinant of edge and near‐edge loading damage propensity. © 2011 Orthopaedic Research Society Published by Wiley Periodicals, Inc. J Orthop Res 30:169–177, 2012  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏