首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Background: The range of the diameters of pulmonary arteries (PA) is not fully shown in the current literature. Contrast-enhanced computed tomography (CT) of the thorax might be used for measuring diameters of the PA.

Purpose: To determine the diameters of PAs in subjects with normal PA pressure by using thoracic CT.

Material and Methods: 126 subjects aged between 19 and 46 years, having normal thoracic CTs (5-mm slice thickness) and normal PA pressures (≤25 mmHg, determined by echocardiography), were included in the study. The diameters of the main, right, and left PAs were measured by using multidetector CT.

Results: The main PA diameters of all the subjects showed a normal distribution, and the mean was 24.0±2.8 mm. The main PA diameters in male and female subjects also showed a normal distribution. The difference between the sexes for the main PA diameters was not significant (P = 0.08). There were correlations between main PA diameter and body-mass index (BMI) (R = 0.41, P = 0.001) and weight (R = 0.34, P = 0.001). However, there was no significant correlation between main PA diameter and height (R = 0.05, P = 0.6).

Conclusion: This study suggests that diameters of the main PA and its main branches show a normal distribution in subjects having normal PA pressures. Based on our findings, the upper limits of the main, right, and left PA diameters are 29.5 mm, 19.8 mm, and 22.1 mm, respectively, in healthy adults.  相似文献   

2.
Background: Magnetic resonance arthrography is a well-established diagnostic method in degenerative and traumatic disorders of the shoulder. Some radiologists prefer to apply a local anesthetic to the skin prior to performing the joint puncture. However, no information regarding the efficacy of local anesthetics exists.

Purpose: To assess patient discomfort in arthrography injection.

Material and Methods: A patient survey (n = 74) utilizing a visual analog scale (VAS) measured the intensity of pain in arthrography injection by those receiving local anesthetics (n = 36) versus those who did not (n = 38).

Results: Mean VAS scores were 20.8 (median 10.5, SD 24.3) for those receiving local anesthetics versus 19.3 (median 13.0, SD 20.7) for those who did not (P = 0.83, Mann-Whitney U test).

Conclusion: Routine use of local anesthesia of the skin in arthrography injection is unnecessary.  相似文献   

3.
Background: Renal artery stenosis may produce hypertension, and this condition is referred to as renovascular hypertension (RVH).

Purpose: To evaluate, by using multidetector-row spiral computed tomographic angiography (MDCTA), whether a relationship between accessory renal artery stenosis and hypertension may be hypothesized.

Material and Methods: 214 patients (142 males, 72 females; mean age 66 years) who had previously undergone an MDCTA to study the abdominal vasculature were retrospectively studied. Patients with renal artery stenosis (RAS) were excluded from this analysis. The patients were studied by means of a four-detector-row CT, and scans were obtained after intravenous bolus administration of 110-140 ml of a nonionic contrast material with a 3-6 ml/s flow rate. As a second step, by means of statistical analysis, hypertension data were compared with findings of accessory artery stenosis. Two radiologists first independently reviewed the MDCTA images and then, in case of disagreement, in consensus. Interobserver agreement was calculated for all measurements.

Results: The overall number of detected accessory renal arteries was 74 in 56 of the 214 patients. Accessory renal artery stenosis was detected in 21 of the 56 patients. There was a difference in the prevalence of hypertension between patients with (n = 21) and without (n = 35) accessory renal artery stenosis (P = 0.0187). Interobserver agreement was good (kappa value 0.733).

Conclusion: Any statistical association between the presence of accessory renal artery stenosis and hypertension could not be disclosed. However, accessory renal artery stenosis, detected by MDCTA, is an important pathological sign that the radiologist has to assess in the light of its possible association with hypertension.  相似文献   

4.
Background: The sail sign is a well-known radiographic feature of the pediatric chest. This sign can be observed in an adult population as well, but for a different reason.

Purpose: To investigate the sail sign appearing in adult chest radiography.

Material and Methods: Based on two anecdotal adult cases in which frontal chest radiographs showed the sail sign, we prospectively screened radiographs of 10,238 patients to determine the incidence of the sail sign found in adults in their 40s or older. The cause of the sail sign was assessed using computed tomography (CT).

Results: The sail sign was revealed in 10 (seven males, three females; median age 60.6 years) of 10,238 patients. Of these 10 patients with a sail sign on frontal radiographs, eight underwent CT. The frontal radiographs of these 10 patients showed a concave superior margin toward the lung in nine patients, a concave inferior margin in five, and a double-lined inferior margin in three. Lateral radiographs disclosed a focal opacity over the minor fissure in five of six patients, which was either fuzzy (n = 4) or sharp (n = 1) in its upper margin, and was sometimes double lined in the inferior margin (n = 3). CT revealed the anterior mediastinal fat to be the cause of the radiographic sail sign, which stretched laterally from the mediastinum to insinuate into the minor fissure.

Conclusion: The incidence of sail sign on adult chest radiographs is about 0.1%. The sign is specific enough to eliminate the need for more sophisticated imaging.  相似文献   

5.
Purpose: To analyze the influence of different biphasic and monophasic injection rate protocols in abdominal computed tomography (CT).

Material and Methods: A randomized, consecutive, parallel group study was designed and conducted in 60 patients studied with the same CT helical protocol. Patients were randomly distributed into three groups: (A) monophasic (120 ml at 2.5 ml/s); (B) low-high biphasic (120 ml, first 60 ml at a rate of 2 ml/s, the other 60 ml at 2.5 ml/s); and (C) high-low biphasic (120 ml, first 60 ml at a rate of 2.5 ml/s, the other 60 ml at 2 ml/s). All patients were injected with 300 mg I/ml non-ionic contrast media at a fixed delay time of 55 s. Contrast enhancement efficacy was evaluated by attenuation coefficient measurements.

Results: Although non-significant, monophasic protocol enhancements were higher than biphasic protocol enhancements in all measurements except aortic bifurcation (p = 0.003). At this level, biphasic protocols obtained an increased mean enhancement from 7.6% to 2.5% compared to monophasic protocols.

Conclusion: Monophasic contrast agent injection in helical CT of the upper abdomen produces a higher enhancement of parenchymal and venous structures. No significant difference was observed between low-high and high-low biphasic protocols.  相似文献   

6.
Purpose: To determine whether the apparent diffusion coefficient (ADC) and fractional anisotropy (FA) can distinguish tumor-infiltrated edema in gliomas from pure edema in meningiomas and metastases.

Material and Methods: Thirty patients were studied: 18 WHO grade III or IV gliomas, 7 meningiomas, and 5 metastatic lesions. ADC and FA were determined from ROIs placed in peritumoral areas with T2-signal changes, adjacent normal appearing white matter (NAWM), and corresponding areas in the contralateral healthy brain. Values and lesion-to-brain ratios from gliomas were compared to those from meningiomas and metastases.

Results: Values and lesion-to-brain ratios of ADC and FA in peritumoral areas with T2-signal changes did not differ between gliomas, meningiomas, and metastases (P = 0.40, P = 0.40, P = 0.61, P = 0.34). Values of ADC and FA and the lesion-to-brain ratio of FA in the adjacent NAWM did not differ between tumor types (P = 0.74, P = 0.25, and P = 0.31). The lesion-to-brain ratio of ADC in the adjacent NAWM was higher in gliomas than in meningiomas and metastases (P = 0.004), but overlapped between tumor types.

Conclusion: Values and lesion-to-brain ratios of ADC and FA in areas with T2-signal changes surrounding intracranial tumors and adjacent NAWM were not helpful for distinguishing pure edema from tumor-infiltrated edema when data from gliomas, meningiomas, and metastases were compared.  相似文献   

7.
Background: Transcatheter arterial embolization (TAE) is a safe and well-established treatment option to control hemoptysis, but there are few studies focused on treating hemoptysis accompanying coal workers' pneumoconiosis (CWP).

Purpose: To evaluate the immediate and long-term efficacy of TAE for control of massive hemoptysis in patients with CWP, and to clarify the factors which influence the frequency of rebleeding.

Material and Methods: This study included 34 CWP patients with massive hemoptysis who were treated with 47 TAE sessions over the last 11 years. Immediate (within 1 month) and long-term outcomes (mean 37 months, range 1 month-11 years) were evaluated retrospectively. The relationships between the frequency of rebleeding and the type of CWP, angiographic findings, and presence of tuberculosis were evaluated.

Results: The immediate success rate was 91.2% (31/34). In 23 patients (68%), hemoptysis did not recur on long-term follow-up. In eight patients who received repeated procedures for recurrent hemoptysis, bleeding was discovered in the non-bronchial systemic artery (n = 13) or bronchial artery (n = 7). The frequency of recurrent hemoptysis was higher in cases with complicated pneumoconiosis (n = 7) than in cases of the simple type (n = 1; P = 0.029). There was no statistical difference between rebleeding and angiographic findings or the presence of tuberculosis.

Conclusion: TAE is an effective treatment modality for controlling massive hemoptysis in patients with CWP. However, many non-bronchial systemic collaterals contribute to recurrent hemoptysis. Furthermore, there is a high probability of rebleeding in patients with the complicated type of CWP, and extra care must be taken in the embolization procedure.  相似文献   

8.
Background: Hepatic microcirculation is a main determinant of reperfusion injury and graft quality in liver transplantation. One of the important diagnostic procedures to recognize reperfusion failure is contrast-enhanced computed tomography or magnetic resonance imaging.

Purpose: To examine the additional effect of contrast media (iomeprol and gadopentetate dimeglumine) on hepatic microcirculation and hepatic cellular damage in the phase of early ischemia/reperfusion injury of the rat liver.

Material and Methods: The partial warm ischemia-reperfusion injury model of rat liver was used. Microcirculation and leukocyte-endothelium interaction were measured by intravital microscopy. Hepatic cellular damage was indicated by liver enzyme activity in the sera. The evaluation parameters were measured at baseline and at 30, 60, and 90 min after reperfusion. The contrast media (iomeprol group, n = 6; gadopentetate dimeglumine group, n = 6) or Ringer's solution (control group, n = 8) were applied after 30 min of reperfusion.

Results: No additional injury to the ischemia/reperfusion injury of the liver after intravenous application of radiographic contrast media was found. Some protective effect was even recorded after application of iodinated contrast media.

Conclusion: The use of contrast media during diagnostic procedure of the liver seems to be relatively safe, even in the stage of early reperfusion after liver transplantation.  相似文献   

9.
Background: In patients with chronic left ventricular dysfunction, the size of the viable cardiac muscle is correlated with the prognosis and the outcome of myocardial revascularization.

Purpose: To evaluate the diagnostic value of various imaging techniques in determination of myocardial ischemia and viability.

Material and Methods: A chronic myocardial ischemia animal model was established, in which 10 pigs underwent magnetic resonance imaging (MRI), positron emission tomography (PET), and single-photon emission computed tomography (201Tl SPECT) before and 1-2 months after modeling. The size of myocardial ischemia and necrosis was judged, and the imaging manifestations were compared with pathologic findings.

Results: Seven of the 10 animals completed all examinations uneventfully. On dobutamine-stressed cine MRI, 10 (8.93%) segments were found to be akinetic. Perfusion was abnormal in 34 (30.35%) segments. Delayed hyperenhancement was observed in 12 (10.71%) segments. PET detected myocardial necrosis in 17 (15.18%) segments, and SPECT detected myocardial necrosis in nine (8.04%) segments. Histological examination with triphenyltetrazolium chloride (TTC) showed pale necrosis in 14 (12.50%) segments. The number of necrotic segments detected by PET was significantly greater than that by contrast-enhanced MRI (χ2 = 5, P = 0.0253, kappa = 0.8028) and cine MRI (χ2 = 7, P = 0.0082, kappa = 0.7079). It was also greater than that by TTC (χ2 = 3, P = 0.0833, kappa = 0.8879), although the difference was statistically insignificant. The number of necrotic segments detected by SPECT was significantly smaller than that by TTC (χ2 = 5, P = 0.0253, kappa = 0.7590), as was the number of necrotic segments detected by cine MRI (χ2 = 4, P = 0.0455, kappa = 0.8100). There was no statistically significant difference in the detection of necrotic segments between contrast-enhanced MRI and TTC (χ2 = 2, P = 0.1573, kappa = 0.9130).

Conclusion: Cardiac MRI can determine viable myocardium and clearly delineate the location and degree of myocardial necrosis. PET slightly overestimates the extent of the necrotic myocardium and is unable to distinguish transmural necrosis from subendocardial necrosis.  相似文献   

10.
Purpose: To compare the use of a new 64-slice computed tomography (CT) scanner with 16-slice CT in the visualization of coronary artery stent lumen.

Material and Methods: Eight different coronary artery stents, each with a diameter of 3 mm, were placed in a static chest phantom. The phantom was positioned in the CT gantry at an angle of 0° and 45° towards the z-axis and examined with both a 64-slice and a 16-slice CT scanner. Effective slice thickness was 0.6 mm with 64-slice CT and 1 mm with 16-slice CT. A reconstruction increment of 0.3 mm was applied in both scanners. Image quality was assessed visually using a 5-point grading scale. Stent diameters were measured and compared using paired Wilcoxon tests.

Results: Artificial lumen reduction was significantly less with 64-slice than with 16-slice CT. Average visible stent lumen was 53.4% using 64-slice CT and 47.5% with 16-slice MSCT. Most severe artifacts were seen in stents with radiopaque markers. Using 64-slice CT, image noise increased by approximately 30% due to thinner slice thickness.

Conclusion: Improved spatial resolution of 64-slice CT resulted in superior assessment of coronary artery stent lumen compared to 16-slice CT. However, a relevant part of the stent lumen is still not assessable with multi-slice CT.  相似文献   

11.
Background: Magnetic resonance (MR) imaging and measurement of glycosaminoglycan (GAG) have potential for characterization of hyaline articular cartilage. Recently, some reports have demonstrated the potential of direct administration of contrast media for MR imaging of cartilage.

Purpose: To prove the feasibility of intraarticular gadolinium-enhanced MR imaging of cartilage (iGEMRIC) and T1 relaxation mapping of the articular cartilage in vivo with intraarticular injection of Gd-DTPA2-.

Material and Methods: Five healthy beagle dogs underwent MR imaging and T1 relaxation mapping of the knee joints of both hind legs. The delayed gadolinium-enhanced MR imaging of cartilage (dGEMRIC) and iGEMRIC techniques were interchanged with MR imaging. For dGEMRIC, a double routine dose of Gd-DTPA2- (0.2 mM/kg) was administered intravenously. For iGEMRIC, 2.5 and 1.25 mmol/l saline-diluted Gd-DTPA2- solutions were separately injected into the right and left knee joints, respectively, prior to MR imaging. Color-coded T1 maps of 20 femoral condyles were obtained from the dGEMRIC and iGEMRIC images. The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and glycosaminoglycan (GAG) delineation of articular cartilage were compared between the dGEMRIC and iGEMRIC techniques.

Results: The mean SNR was higher with dGEMRIC than with iGEMRIC, but the difference was not statistically significant (P = 0.174). The mean (±SD) CNR was higher with iGEMRIC (-11.6±3.4) than with dGEMRIC (-16.7±4.0; P = 0.000), although the absolute value of the CNR was higher with dGEMRIC. The layering and gradient distribution of GAG were more clearly visualized on the iGEMRIC images. The mean scores of GAG delineation with dGEMRIC and iGEMRIC were 0.7±0.6 and 2.2±1.7, respectively. The iGEMRIC method better visualized GAG distribution (P = 0.001).

Conclusion: Although the SNR did not differ significantly between the iGEMRIC and dGEMRIC techniques, the color-coded T1 map produced with iGEMRIC allowed better cartilage evaluation. Thus, iGEMRIC exhibits the useful features of both MR arthrography and dGEMRIC, and provides a color-coded T1 map that is useful for diagnosing early articular cartilage damage.  相似文献   

12.
Purpose: To assess the safety and clinical effectiveness of the parallel placement of covered retrievable expandable metallic stents in the palliative treatment of malignant esophageal and tracheobronchial strictures.

Material and Methods: Under fluoroscopic guidance, parallel stents were placed in 12 symptomatic patients with both malignant esophageal and tracheobronchial strictures. Seven of these 12 patients also had an esophagorespiratory fistula (ERF) and one patient had an esophagocutaneous fistula. Technical success, clinical improvement, complications, and survival rates were evaluated.

Results: A total of 28 esophageal and airway stents were successfully placed. The grade of dysphagia and dyspnea score significantly decreased after stent placement (P = 0.002 and 0.003, respectively). ERF and esophagocutaneous fistula were sealed off in all eight patients after esophageal stent placement; however, the esophagocutaneous fistula reopened 1 month later. Complications included stent migration or expectoration (n = 3), tracheal compression by the esophageal stent (n = 3), new fistula development due to covering membrane degradation of the esophageal stent (n = 1), and symptomatic sputum retention (n = 1). Stent removal was easily performed for two stents; one migrated stent and the other with covering membrane degradation. All 12 patients died within the mean survival period of 72.50 days (range 7-375 days).

Conclusion: Parallel placement of covered retrievable expandable metallic stents is safe and effective for the palliative treatment of malignant esophageal and tracheobronchial strictures.  相似文献   

13.
Background: Attempts to retrieve absolute values of cerebral blood flow (CBF) by dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) have typically resulted in overestimations.

Purpose: To improve DSC-MRI CBF estimates by calibrating the DSC-MRI-based cerebral blood volume (CBV) with a corresponding T1-weighted (T1W) steady-state (ss) CBV estimate.

Material and Methods: 17 volunteers were investigated by DSC-MRI and 133Xe SPECT. Steady-state CBV calculation, assuming no water exchange, was accomplished using signal values from blood and tissue, before and after contrast agent, obtained by T1W spin-echo imaging. Using steady-state and DSC-MRI CBV estimates, a calibration factor K = CBV(ss)/CBV(DSC) was obtained for each individual. Average whole-brain CBF(DSC) was calculated, and the corrected MRI-based CBF estimate was given by CBF(ss) = K×CBF(DSC).

Results: Average whole-brain SPECT CBF was 40.1±6.9 ml/min·100 g, while the corresponding uncorrected DSC-MRI-based value was 69.2±13.8 ml/min·100 g. After correction with the calibration factor, a CBF(ss) of 42.7±14.0 ml/min·100 g was obtained. The linear fit to CBF(ss)-versus-CBF(SPECT) data was close to proportionality (R = 0.52).

Conclusion: Calibration by steady-state CBV reduced the population average CBF to a reasonable level, and a modest linear correlation with the reference 133Xe SPECT technique was observed. Possible explanations for the limited accuracy are, for example, large-vessel partial-volume effects, low post-contrast signal enhancement in T1W images, and water-exchange effects.  相似文献   

14.
Purpose: To describe timed barium esophagogram (TBE) characteristics in patients with newly diagnosed idiopathic achalasia, and to correlate these with clinical and manometric variables.

Material and Methods: Forty-six consecutive patients with newly diagnosed achalasia were examined with TBE. Esophageal emptying was assessed using the height, area, and volume of the barium column. Subjective evaluation was performed according to a standardized protocol in all patients. Objective diagnostic evaluation included manometry.

Results: At the 1-min time point after contrast ingestion, the static parameters median height, maximum, and mean width of the barium column were 16.0, 4.4, and 3.3 cm, respectively. Emptying, expressed as volume of barium, showed significant inverse correlation with the resting and the maximal relaxing pressure of the lower esophageal sphincter (LES) (R = -0.34 and R = -0.54, respectively). There was also an inverse correlation between emptied volume at TBE and the duration of symptoms (R = -0.36), and between barium column width and postprandial chest pain (R = -0.44).

Conclusion: All patients with newly diagnosed achalasia presented with delayed emptying of barium the esophagus at TBE. The estimated emptied volume of barium (related to the ingested volume) correlated inversely with the basal tone and the relaxation pressure of the LES. Including estimation of the volume of emptied barium at TBE resulted in closer correlation with manometric values of LES tone than using the parameters traditionally recorded.  相似文献   

15.
Purpose: To describe the findings of hyperperfusion on perfusion computed tomography (CT) in four patients following revascularization for acute stroke.

Material and Methods: In 2002-2003, among a series of 6 patients presenting with an acute stroke and treated with intra-arterial thrombolysis, we observed the presence of hyperperfusion in 3 patients on the follow-up CT perfusion. We included an additional patient who was treated with intravenous thrombolysis and who had hyperperfusion on the follow-up CT perfusion. We retrospectively analyzed their CT perfusion maps. Cerebral blood volume (CBV) and cerebral blood flow (CBF) maps were compared between the affected territory and the normal contralateral hemisphere.

Results: In the four patients, the mean CBV and CBF were 3.6±2.0 ml/100 g and 39±25 ml/100 g/min in the affected territory compared to the normal side (mean CBV = 2.7±2.1 ml/100 g, mean CBF = 27±23 ml/100 g/min). There was no intracranial hemorrhage in the hyperperfused territories. At follow-up CT, some hyperperfused brain areas progressed to infarction, while others retained normal white to gray matter differentiation.

Conclusion: CT perfusion can demonstrate hyperperfusion, which can be seen in an ischemic brain territory following recanalization.  相似文献   

16.
Background: A matter of substantial concern regarding all needle biopsy techniques is seeding along the biopsy needle tract.

Purpose: To assess cell seeding along the needle tract of vacuum-assisted breast biopsy (VABB).

Material and Methods: The study included 21 patients with ductal carcinoma in situ (DCIS) and 10 patients with invasive ductal carcinoma (IDC) diagnosed by VABB for nonpalpable mammographic lesions. VABB (11G, on a Fischer table) was performed, and the duration of the procedure was measured. After surgery, the whole needle tract was embedded in paraffin blocks, stained with hematoxylin-eosin, and examined by a pathologist.

Results: Cases with dissemination of cancer cells in the needle tract were not observed (one-sided 97.5% CI 0-10.0%). In 2/31 (6.5%) cases (95% CI 0.8-21.4%), benign epithelial cell displacement was observed, and the duration of VABB was significantly longer in these two cases (52.5±3.5 min vs. 42.0±4.4 min for cases without benign cell displacement; P = 0.018, Mann-Whitney-Wilcoxon test for independent samples).

Conclusion: No displacement of malignant cells within the 11G needle tract was documented. Benign cell displacement was associated with longer VABB duration. The phenomenon of tumor cell dissemination along the needle tract is of questionable clinical significance when the treatment guidelines are followed.  相似文献   

17.
Background: Multidetector computed tomography (MDCT) enterography combines neutral enteric contrast with intravenously administered contrast material. The optimal intravenous (IV) contrast material protocol has still not been established.

Purpose: To determine the optimal delay time to image patients with small-bowel Crohn's disease during MDCT enterography.

Material and Methods: After oral administration of 1350 ml of neutral contrast medium, 26 patients with small-bowel Crohn's disease underwent MDCT enterography; scans were obtained 40 s (enteric phase) and 70 s (parenchymal phase) after IV administration of 100 ml of iodinated contrast material. Three radiologists, blinded to clinical and pathological findings, independently and retrospectively evaluated each scan in two separate reading sessions for the presence or absence of CT features of Crohn's disease activity. The interobserver agreement was evaluated, and the efficacy of each phase in detecting active disease in the terminal ileum for each reader was determined. The gold standard was pathology (n = 13), endoscopy (n = 3), and clinical evaluation (n = 10).

Results: No statistically significant difference was present between the enteric and the parenchymal phase for each reader in each segment regarding the presence or absence of CT features of Crohn's disease. The interobserver agreement for the presence of five main features of active Crohn's disease in the terminal ileum ranged from poor to excellent. The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for active Crohn's disease in the terminal ileum ranged from 40 to 90%, 88 to 100%, 70 to 94%, 44 to 100%, and 69 to 96%, respectively. There was no statistical difference between the two phases for each reader.

Conclusion: MDCT enterography in patients with suspected active Crohn's disease can be obtained at either 40 s or 70 s after IV contrast material.  相似文献   

18.
Purpose: To evaluate the learning curve for an add-on 14 G stereotactic core needle biopsy (SCNB).

Material and Methods: A total of 231 non-palpable breast lesions that had undergone add-on SCNB were evaluated in this prospective study. Five radiologists performed their first three biopsies under supervision. Subsequent, independently performed, biopsies were also evaluated. The samples were collected in three different containers: the first sample in container A, the second and third samples in container B, and subsequent samples in container C (available for four radiologists from the first biopsy on). Technically successful biopsies and false-negative rate in three container combinations (A, A+B, A+B+C) were reported as a function of operator experience.

Results: Technically unsuccessful biopsies occurred significantly more often in microcalcifications than in masses (14.9% versus 3.8%; P = 0.04). For microcalcifications, the rate of successful biopsies was 75% (18/24) for the first 5 biopsies and 87.8% (79/90) for the subsequent biopsies (P = 0.335); rates for the masses were 95.7% (22/23) and 96.3% (79/82) (P = 1.0), respectively. A tendency was noted for the false-negative rate to be higher for the first five biopsies in three container combinations than in subsequent cases.

Conclusion: Our results support the existence of a learning curve, especially in the biopsy of microcalcifications. More than three mentor-guided biopsies are needed.  相似文献   

19.
Purpose: To investigate whether saline pushing after contrast material improves hepatic vascular and parenchymal enhancement, and to determine whether this technique permits decreased contrast material concentration.

Material and Methods: 120 patients who underwent hepatic multidetector computed tomography were divided randomly into four groups (Groups A-D): receiving 100 ml of contrast material (300 mgI/ml) only (A) or with 50 ml of saline solution (B); or 100 ml of contrast material (350 mgI/ml) only (C) or with 50 ml of saline solution (D). Computed tomography (CT) values of the aorta in the arterial phase, the portal vein in the portal venous inflow phase, and the liver in the hepatic phase were measured. Visualization of the hepatic artery and the portal vein by 3D CT angiography was evaluated as well.

Results: Although the enhancement values of the aorta were not improved significantly with saline pushing, they continued at a high level to the latter slices with saline pushing. The enhancement value of the portal vein increased significantly and CT portography was improved with saline pushing. The enhancement value of the liver was not improved significantly using saline pushing. In a comparison between groups B and C, the enhancement values of the aorta and portal vein and the visualization of CT arteriography and portography were not statistically different.

Conclusion: The saline pushing technique can contribute to a decrease in contrast material concentration for 3D CT arteriography and portography.  相似文献   

20.
Purpose: To evaluate whether non-contrast multidetector computed tomography (MDCT) for suspected acute knee fractures can also be used to evaluate cruciate ligament pathology.

Material and Methods: A total of 42 patients (17-65 years) underwent four-section MDCT. The images were independently evaluated at clinical workstations by four radiologists. They assessed the integrity (normal or torn) and the best slice direction (axial, sagittal, or coronal) for visualization of the cruciate ligaments. Magnetic resonance imaging (MRI), performed within 4 weeks (mean 6 days) in relation to MDCT, was considered the gold standard.

Results: Ligament integrity at MDCT: the mean interobserver proportion of agreement for a normal anterior cruciate ligament (ACL) was 0.73, for a torn ACL 0.41, for a normal posterior cruciate ligament (PCL) 0.96, and for a torn PCL 0.54. Interobserver variation for ACL was significant (P = 0.0136-0.0260), but insignificant for PCL (P = 0.3389-0.7212). Intra-observer variation was insignificant. Visualization was best in the axial and sagittal direction for ACL and PCL, respectively. At MRI, 29 normal, one partially, and 12 completely torn ACLs, and 37 normal, four partially and one completely torn PCL were found.

Conclusion: MDCT can detect an intact ACL and PCL with good specificity, accuracy, and negative predictive value. The assessment of torn ligaments is unreliable.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号