首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Background

Obesity is a risk factor for acetabular component malposition when total hip arthroplasty is performed with manual techniques. The utility of imageless navigation in obese patients remains unknown. This study compared the accuracy and precision of imageless navigation for component orientation between obese and nonobese patients.

Methods

A total of 459 total hip arthroplasties performed for osteoarthritis using imageless navigation were reviewed from a single surgeon’s institutional review board–approved database. Einzel-Bild-Roentgen Analyse determined component orientation on 6-week postoperative anteroposterior radiographs. Mean orientation error (accuracy) and precision were compared between obese (body mass index ≥ 30 kg/m2) and nonobese patients. Regression analysis evaluated the influence of obesity on component position.

Results

The difference in mean inclination and anteversion between obese and nonobese groups was 1.1° (43.0° ± 3.5°; range, 35.8°-57.8° vs 41.9° ± 4.4°; range, 33.0°-57.1° and 24.9° ± 6.3°; range, 14.2°-44.3° vs 23.8° ± 6.6°; range, 7.0°-38.6°, respectively). Inclination precision was better for nonobese patients. No difference in inclination accuracy or anteversion accuracy or precision was detected between groups. And 83% of components were placed within the target range. There was no relationship between obesity (dichotomized) and component placement outside the target ranges for inclination, anteversion, or both. As a continuous variable, increased body mass index correlated with higher odds of inclination outside the target zone (odds ratio, 1.06; P = .001).

Conclusion

Using imageless navigation, inclination orientation was less precise for obese patients, but the observed difference is likely not clinically relevant. Accurate superficial registration of landmarks in obese patients is achievable, and the use of imageless navigation similarly improves acetabular component positioning in obese and nonobese patients.

Level of Evidence

Therapeutic Level IV.  相似文献   

2.

Background

Highly cross-linked polyethylene (HXLPE) liners in total hip arthroplasty (THA) have demonstrated decreased wear rates, resilience to cup orientation, and reduced osteolysis compared to conventional polyethylene. Sequential irradiation and annealing below the melting temperature is unique compared to most HXLPE which is irradiated and remelted. This study purpose is to provide minimum 5-year femoral head penetration rates of sequentially annealed HXLPE in primary THA.

Methods

A retrospective review of a prospectively collected database identified 198 consecutive, cementless primary THAs utilizing sequentially annealed HXLPE (X3; Stryker, Mahwah, NJ). Operative technique was standardized. Radiographs were analyzed utilizing the Martell method with minimum 5-year and 1-year radiographs as baseline to minimize the initial bedding-in period.

Results

Seventy-seven hips with minimum 5-year follow-up were analyzed. Mean steady state linear and volumetric head penetration rates were 0.095 mm/y and 76 mm3/y, respectively. Volumetric head penetration was significantly less for 32-mm compared to 36-mm (P = .028). In addition, less head penetration was observed for ceramic 32-mm heads at nearly half the rate compared to cobalt-chromium 36-mm heads (P ≥ .092). No correlations existed between penetration rates and age, body mass index, University of California Los Angeles Activity Level, polyethylene thickness, cup inclination, or anteversion (P ≥ .10). No radiographic osteolysis was observed.

Conclusion

Surprisingly, linear head penetration rates of sequentially annealed HXLPE were nearly identical to the osteolysis threshold for conventional polyethylene and greater than reports of irradiated and remelted HXLPE. Furthermore, these data corroborate reports that HXLPE is resilient to cup orientation and demographic variables. Longer term follow-up is recommended.  相似文献   

3.

Background

Although most hip dislocations occur in either standing or sitting position, the safe zone for implant position is defined for the supine position. Our goal was to determine preoperative and postoperative pelvis and hip orientations and whether the safe zone defined in supine position can be used to assess standing radiographs.

Methods

Preoperative and postoperative three-dimensional EOS images were assessed in 66 total hip arthroplasty patients. None of the patients had dislocation within the follow-up period (12-36 months). The acetabular anteversion (both anterior pelvic plane [APP] and patient functional plane) and the femoral anteversion were measured. The sacral slope, pelvic version, pelvic inclination, and pelvic incidence were also measured.

Results

Acetabular anteversion increased postoperatively in both APP and patient functional plane (P <.001). Femoral neck anteversion decreased postoperatively (P =.0942). Sacral slope was 42.4° (?25.9° to 24°) preoperatively compared with 40.3° (?4.1° to 64.2°) postoperatively (P =.013). Pelvic version changed from 15.2° (?10.4° to 43.8°) to 17.2° (?6° to 46.7°; P = 0.008). Pelvic inclination was 1.12° (?25.9° to 24°) before total hip arthroplasty and ?1.2° (?40.7° to 23.4°) postoperatively (P =.005).

Conclusion

The acetabular and femoral implant orientations in standing position reside out of the safe zone in most patients. The APP is not vertical in standing position in most patients due to anterior or posterior pelvic tilt. The proposed safe zone in supine position may not be a useful measure in the assessment of standing radiographs of patients with significant anterior or posterior pelvic tilt.

Level of Evidence

Level IV, therapeutic case series study.  相似文献   

4.

Background

About 50%-70% of dislocators have cups placed within so-called “safe zones.” It has been postulated that factors such as femoral head size and pelvic tilt, obliquity, or rotation may influence postoperative stability. Therefore, we assessed varying degrees of pelvic tilt and head sizes on the range of motion (ROM) to impingement.

Methods

A hip simulator was used to import models of 10 subjects who performed object pickup, squatting, and low-chair rising. Parameters were set for pelvic tilt, stem version, and the specific motions as defined by the subjects. Femur-to-pelvis relative motions were determined for abduction/adduction, internal/external rotation, and flexion/extension. Varying tilt angles were tested. Thirty-two millimeter and 36-mm head with a standard cup and 42-mm dual mobility cup were tested. Cup orientations for abduction and anteversion combinations were chosen, and computations of minimum clearances or impingement between components were made.

Results

The ROM to impingement varied with the different pelvic tilts and femoral head sizes and with the different motions. The larger the head size, the larger the impingement-free ROM. Negative 10° of pelvic tilt led to the largest impingement-free zone, whereas 10° of forward tilt was associated with fewer impingement-free cup anteversion and abduction angle combinations. Variations in pelvic tilt had the greatest influence on object pickup and affected the impingement-free “safe zone.”

Conclusion

Targets for impingement-free motion may be smaller when considering varying pelvic tilts and femoral head sizes, particularly for certain activities, such as object pickup. These findings may indicate the need for more individualized patient planning.  相似文献   

5.

Study Design

A within-subject research design was used in this study. The difference of the range of motion (ROM) with and without ulnar nerve block was analyzed.

Introduction

For the clinical evaluation of the functional effects of ulnar nerve palsy at the hand the relevance of clinical tests is in discussion.

Purpose of the Study

The aim of the study was to evaluate the predictive value of 2 clinical tests for a simulated ulnar nerve lesion by motion analysis with a sensor glove.

Methods

In 28 healthy subjects, dynamic measurements of the finger joints were performed by a sensor glove with and without ulnar nerve block at the wrist. In the 0° metacarpophalangeal (MCP) stabilization test, the subjects were asked to stabilize the MCP joints actively in 0° while moving the interphalangeal joints, whereas at the 90° MCP stabilization test, the subjects stabilized the MCP joints actively in the 90° position.

Results

In the 0° MCP stabilization test, no remarkable changes of the ROM were found at the MCP joints; at the proximal interphalangeal joints 2-5, the ROM decreased with ulnar nerve block, significantly at the index, middle, and ring fingers (P < .05). In the 90° MCP stabilization test, the average ROM of the MCP joints 2-5 significantly increased with ulnar nerve block (P < .05), whereas at the PIP joints, the average ROM decreased (P < .05).

Discussion

The 90° MCP stabilization test had a high predictive value for the discrimination between healthy subjects and subjects with a simulated peripheral ulnar nerve lesion.

Conclusions

The results could be relevant for the determination of the functional effect of ulnar nerve palsy and the quantification of clawing in hand rehabilitation.

Level of Evidence

II.  相似文献   

6.

Background

This study used EOS imaging of primary total hip arthroplasty (THA) patients, with and without predating spinal fusion, to investigate (1) the impact of spinal fusion on acetabular implant anteversion and inclination, and (2) whether more extensive spinal fusion (fusion starting above the thoracolumbar junction or extension of fusion to the sacrum) affects acetabular implant orientation differently than lumbar only spinal fusion.

Methods

Ninety-three patients had spinal fusion (case group), and 150 patients were without spinal fusion (controls). None of the patients experienced dislocation. The change in sacral slope (SS) and cup orientation from standing to sitting was measured.

Results

Mean SS change from the standing to sitting positions was ?7.9°in the fusion group vs ?18.4°in controls (P = .0001). Mean change in cup inclination from the standing to sitting positions was 4.9°in the fusion group vs 10.2°in controls (P = .0001). Mean change in cup anteversion from standing to sitting positions was 7.1°in the fusion group vs 12.1°in controls (P = .0001). For each additional level of spinal fusion, the change in SS from standing to sitting positions decreased by 1.6(95% confidence interval [CI], 2.2073-1.0741), the change in cup inclination decreased by 0.8(95% CI, 0.380-1.203), and the change in cup anteversion decreased by 0.9(95% CI, 0.518-1.352; P < .001 in all cases).

Conclusion

Patients with spinal fusion demonstrated less adaptability of the lumbosacral junction. Longer spinal fusion or inclusion of the pelvis in the fusion critically impacts hip-spine biomechanics and significantly affects the ability to compensate in the standing-to-sitting transition.  相似文献   

7.

Background

Acetabular cup placement in total hip arthroplasty (THA) has been recognized as an important factor in operative success, and accurate cup placement has been the impetus for novel medical technologies.

Methods

This article examines the cup placement in 955 THAs using a freehand Direct Anterior Approach on a standard operating table. Acetabular anteversion and inclination were determined using the circle theorem. Measurements were divided into safe zone placement determined by Callanan et al as 5°-25° for anteversion and 30°-45° for inclination, as well as by Lewinnek et al as 5°-25° for anteversion and 30°-50° for inclination. Dislocation rate was determined and correlated to safe zone placement.

Results

Although technology has advanced for cup placement, this investigation shows that a freehand technique demonstrates 0.31% dislocation after THA with an accuracy of 85% for the Lewinnek safe zone and 61% for Callanan, potentially because of the sparing of the posterior hip capsule.

Conclusion

The direct anterior approach to the hip on a regular operating table is safe and reliable. Our results demonstrate improvement in cup positioning compared with other freehand techniques. Surgeon awareness and control of the position of the pelvis within space optimizes acetabular component accuracy and precision without the need for special equipment, such as intraoperative fluoroscopy.  相似文献   

8.

Background

Due to anterior bone defects, high and/or posterior placement of an acetabular cup is often required to achieve sufficient coverage in patients with hip dysplasia. We examined whether posterior cup placement affected the postoperative range of motion (ROM) in primary total hip arthroplasty (THA).

Methods

Using computer software, bone coverage and ROM were examined in 32 patients with unilateral osteoarthritis of the hip with Crowe type II or III hip dysplasia. We determined the cup position to satisfy cup center-edge (Cup-CE) angle ≥0° and the required ROM. The cup was placed at the anatomic hip center and moved in 2-mm increments anteroposteriorly and 10-mm increments vertically.

Results

At vertical anatomic hip center, less than 68.8% hips fulfilled Cup-CE ≥0° regardless of anteroposterior position. Significantly more hips at higher hip center with posterior cup placement achieved Cup-CE ≥0° than hips at vertical anatomic hip center, and 10 mm higher hip center was the most suitable for achieving bone coverage. However, posterior and superior cup placement significantly decreased the flexion and IR due to early bone impingement, whereas ER and extension were not affected. A smoothing spline curve demonstrated that more posterior cup placement than 4.8 mm and 3.6 mm did not satisfy the required ROM at 10 mm and 20 mm higher hip center, respectively.

Conclusions

Posterosuperior cup placement gained more bone coverage but decreased the range of hip flexion and internal rotation. Consequently, posterosuperior cup placement did not satisfy the required ROM.  相似文献   

9.

Background

Anterior knee pain (AKP) remains a complex issue affecting patient satisfaction after total knee arthroplasty. Several radiographic parameters have been shown to be causative factors with various designs. The aim of this study is to evaluate the known radiographic parameters of AKP and clinical outcomes (ie, AKP) in the setting of a modern prosthesis with an anatomic patella button.

Methods

Between July 2012 and December 2013, 90 total knee arthroplasties received 3 skyline views taken at 30°, 45°, and 60°. A patient-administered questionnaire was administered at 2-year follow-up to assess the incidence of AKP, painless noise, and satisfaction. Radiographs were analyzed for patellofemoral overstuffing, patellar tilt, and patellar displacement, and evaluated the patella resection angle.

Results

On the patient-administered questionnaire, 10 (11.1%) patients reported AKP of a mild-to-moderate nature. Thirty-one had the best view at 30 Merchant views, 24 had best views at 45, and 35 had best views at 60. We found that patellar resection angle correlated with AKP (odds ratio 1.21, P = .044) and painless noise (odds ratio 1.22, P = .034). Patellar displacement and patellofemoral stuffing did not correlate with AKP or painless noise. No radiographic measurements correlated with changes in Knee Society Score pain or function scores or range of motion.

Conclusion

We found that a patellar resection angle correlated with the incidence of AKP and painless noise at 2-year follow-up. We failed to find any correlation with patellofemoral overstuffing, patellar displacement, or patellar tilt with clinical outcomes. We recommend the use of 3 Merchant views to fully evaluate the patellofemoral joint.  相似文献   

10.

Study Design

Cross-sectional study.

Purpose of the Study

The study aims to determine the effects of force direction and arm position in differentiating the clavicular (PMc) and sternal (PMs) parts of the pectoralis major (PM) muscle during maximal voluntary isometric contraction (MVIC) to provide basic evidence to support the clinical thinking behind muscle strength testing of PM.

Methods

Nine experimental conditions with 3 force directions of horizontal adduction (+30° oblique, horizontal, and ?30° oblique to the transverse plane) and 3 arm rotation positions (0°, 45°, and 90° shoulder external rotation from the transverse plane) were randomly tested for 26 healthy male participants. The MVIC force level was monitored and measured with a fixed dynamometer, and the surface electromyographic (EMG) signals of the PMc, PMs, anterior deltoid, middle deltoid, and latissimus dorsi were collected during the test for each condition. The PMc/PMs EMG ratio and normalized EMG amplitude were used to quantify the contribution of the tested muscles.

Results

The MVIC force level significantly declined when the arm's external rotation increased (P < .01; the grand mean decreased from 106.7 N ± 27.8 N to 89.5 N ± 22.6 N). The PMc/PMs EMG ratio showed that the best test condition to differentiate the PMc and PMs was the force direction of +30° oblique to the transverse plane and the 45° arm rotation position. Other muscles contributed less than 40% of their MVIC activity levels, with a higher activation level found in the anterior deltoid muscle (P < .01).

Conclusions

Arm rotation position should be considered as a predominant factor when clinically examining the strength of horizontal adduction movement. All tested conditions failed to fully separate PMc and PMs activation during MVIC and suggested that functional differentiation of the PM might not be applicable to maximal exertion.

Level of Evidence

NA.  相似文献   

11.

Purpose

Reduction and fixation in femoral neck fracture in young patients have a problem of nonunion requiring additional procedure like valgus osteotomy but fixation devices are technically difficult for inexperienced surgeons. We aims to assess the results of valgus osteotomy in femoral neck fracture in our setup.

Methods

We report a series of 20 patients of higher Pauwel's angled fracture of femoral neck fracture presenting late wherein for valgus osteotomy was added to reduction fixation secured with a commonly available 135° dynamic hip screw and plate.

Results

Femoral neck fractures united in 16 patients (80%). Excellent to good results (Harris hip score >80) were seen in 70% patients. Angle of correction of preoperative Pauwels has been changed from 68.3 to 34.3.

Conclusion

135° dynamic hip screw and plate provides rigid internal fixation after valgus osteotomy and being a more familiar fixation device simplifies the procedure with good results.  相似文献   

12.

Background

The purpose of the study was to evaluate the implant positions and clinical results of revision total hip arthroplasty (THA) using an imageless navigation with the concept of combined anteversion.

Methods

A total of 40 cementless revision THAs (24 men and 16 women) using an imageless navigation with the concept of combined anteversion were retrospectively evaluated. The concept of combined anteversion was applied in cup positioning based on Widmer's equation (cup anteversion + 0.7 × stem anteversion). The mean follow-up period was 80.7 months. Postoperatively, the inclination of the cup was evaluated on standard anteroposterior view of the radiograph, and the anteversion of the cup and femoral stem was evaluated using computed tomography scan. A cup inclination of 40° ± 10° and combined anteversion of the cup and femoral stem of 37° ± 10° based on Widmer's equation were regarded as the “safe zone.”

Results

The average anteversion of the revised femoral stems was 15.3° ± 2.9° (range, 9.5°-21.5°), whereas that of the remained femoral stems was 17.4° ± 9.7° (range, 4.2°-29.8°). The inclination, anteversion of the cup, and combined anteversion after revision THA were 42.3° ± 3.1° (range, 32.1°-48.2°), 25.0° ± 2.9° (range, 16.9°-29.5°), and 36.1° ± 3.4° (range, 27.2°-42.9°), respectively. Therefore, the position of the implants, relative to the safe zone, showed no outliers after the revision surgery. Neither dislocation nor osteolysis was observed after the surgery.

Conclusion

Favorable results of this study indicate that imageless navigation helps the surgeon in placing the components of revision THA in the safe zone. This study also shows that when this safe zone is consistently obtained, then no postoperative dislocations were observed in these patients over the 6-year follow-up period.  相似文献   

13.

Background

This study compares the differences in acetabular component position, leg length discrepancy, and hip offset between the anterior and posterior approach. A novel method is applied to determine the acetabular anteversion using the C-arm tilt angle for the anterior approach.

Methods

Hundred consecutive anterior total hip arthroplasties were matched according to gender, body mass index, and age to a cohort of 100 primary total hip arthroplasties operated on through a posterior approach. Postoperative radiographs were analyzed to determine cup inclination, cup anteversion, leg length discrepancy, and hip offset.

Results

The mean inclination was 40.8° (range 33°-48°) and 45.1° (range 33°-55°) for the anterior and posterior approach, respectively. Using the new C-arm tilt plane technique, an average acetabular anteversion of 18.4° (range 11°-26°) was achieved with the anterior approach compared with 23.6° (range 8°-38°) with the posterior approach. Hundred percent cups in the anterior group and 81% in the posterior group fell within the safe zone (P < .001). There was no difference in the overall hip offset between the operated side and the contralateral side for the anterior (P = .074) and posterior (P = .919) group. There was no difference in leg length discrepancy between the 2 approaches (P = .259).

Conclusion

Intraoperative fluoroscopy-assisted direct anterior approach was associated with improved acetabular component positioning. However, no benefit was shown with regards to restoration of hip offset or leg length.  相似文献   

14.

Background

The short-term corrosion and micromechanical behavior of 32 unique head-neck taper design/material/assembly conditions was tested using an incremental cyclic fretting corrosion (ICFC) test method previously developed.

Methods

Seven materials, design, and simulated surgical parameters were evaluated, each being assigned 2 conditions for testing, using a 27-2 (7 factor, quarter factorial) design of experiments test matrix. The factors explored were (1) seating load, (2) head-neck offset, (3) material combination, (4) taper diameter, (5) taper roughness, (6) angular mismatch/engagement, and (7) taper length. Each sample underwent assembly, ICFC testing, pull off.

Results

Low seating load and high head offset correlated with increased fretting corrosion (P < .05). High head offset also contributed to a lower onset load for fretting current and higher micromotion (P < .05). Head subsidence measured over the ICFC test for samples seated at 100 N was significantly higher than samples seated at 4000 N. Micromotion for 12-mm head offsets was statistically higher than samples with a 1.5-mm head offset. A number of interactive effects were observed. For example, samples seated at 4000 N were less sensitive to head offset than samples seated at 100 N in terms of the resulting fretting current.

Conclusion

Taper locking position, material combination, taper engagement length, taper roughness, and taper dimensions all had weak or no correlation with fretting current and taper micromotion. This test method and experimental design is a versatile means of assessing potential new taper designs in the future.  相似文献   

15.

Study Design

Case report.

Introduction

Development of extensor tendon adhesions is a common complication after intra-articular metacarpal head fracture. Whenever these adhesions cannot be mobilized by rehabilitation, tenolysis should be considered. However, the decision for tenolysis is often delayed. When the rehabilitation program comes to a plateau and clinical examination may not be sufficient to find out the cause, dynamic ultrasound (US) can show where the gliding mechanism is disrupted and help clinicians to give an accurate decision for determining the next steps.

Purpose of the Study

To determine the role of dynamic US during hand rehabilitation.

Methods

A 22-year-old woman presented with a fifth metacarpal intra-articular head fracture. Ten days after the surgery (open reduction and internal fixation) the hand rehabilitation program was commenced. After the third week, the metacarpophalangeal (MP) joint range of motion (ROM) gradually diminished. Dynamic US near the level of fifth MP joint revealed diminished extensor tendon excursion and capsular thickening.

Results

Considering physical and sonographic findings, surgical tenolysis and capsular release was planned. After surgery, the DIP, PIP and MP joints reached full passive ROM.

Conclusion(s)

Ultrasound is a quick and practical way to diagnose tendon adhesions. With this report, the authors suggest that clinicians may use dynamic US, especially in times when the patient comes to plateau during hand rehabilitation.

Level of Evidence

IV.  相似文献   

16.
17.

Objective

The aim of this study was to evaluate the radiologic outcomes of open reduction and lateral plating with wiring in the treatment of Vancouver B2 periprosthetic femoral fractures.

Methods

We retrospectively recruited 37 patients treated with ORIF with lateral plating and wiring for Vancouver B2 fractures. The 27 patients (15 men and 12 women; mean age: 70.8 ± 8.3 years) without follow-up loss had achieved complete bony union without notable complications. The average union period was checked after operation with radiologic findings. Radiologic outcomes were evaluated by ipsilateral limb length discrepancy (LLD) and subsidence between immediate postoperative length and length at postoperative 1 year after adjusting for magnification differences. The average distance to which the retained stem sunk down was investigated between immediate postoperative radiographs and final radiographs showing union.

Results

Ten patients could not be evaluated, because of mortality or failure to follow up. The average time to union was 18.3 weeks, and the average distance of stem sinking was 2.5 ± 1.7 mm (range: 0–7.2 mm), which was significantly different between immediate postoperative radiographs and final radiographs. There was no case with loss of reduction or loss of fixation, requiring revision surgery.

Conclusion

Open reduction and lateral plating with wiring as a treatment for Vancouver B2 periprosthetic femoral fractures produced good radiologic outcomes with successful bony union. ORIF can be considered the alternative option for treating patients with Vancouver B2 PPF, instead of stem revision surgery.

Level of evidence

Level IV, Therapeutic study.  相似文献   

18.

Study Design

Two-group randomized controlled trial.

Introduction

Upper limb orthoses worn during functional tasks are commonly used in pediatric neurologic rehabilitation, despite a paucity of high-level evidence.

Purpose of the Study

The purpose of this study was to investigate if a customized functional wrist orthosis, when placed on the limb, leads to an immediate improvement in hand function for children with cerebral palsy or brain injury.

Methods

A 2-group randomized controlled trial involving 30 children was conducted. Participants were randomized to either receive a customized functional wrist orthosis (experimental, n = 15) or not receive an orthosis (control, n = 15). The box and blocks test was administered at baseline and repeated 1 hour after experimental intervention, with the orthosis on if randomized to the orthotic group.

Results

After intervention, there were no significant differences on the box and blocks test between the orthotic group (mean, 10.13; standard deviation, 11.476) and the no orthotic group (mean, 14.07; standard deviation, 11.106; t[28], ?0.954; P = .348; and 95% confidence interval, ?12.380 to 4.513).

Discussion

In contrast to the findings of previous studies, our results suggest that a functional wrist orthosis, when supporting the joint in a ‘typical’ position, may not lead to an immediate improvement in hand function.

Conclusions

Wearing a functional wrist orthosis did not lead to an immediate improvement in the ability of children with cerebral palsy or brain injury to grasp and release. Further research is needed combining upper limb orthoses with task-specific training and measuring outcomes over the medium to long term.  相似文献   

19.

Background

Obesity has been described as an independent risk factor for acetabular component malpositioning. The purpose of this study was to determine if this could be overcome by use of fluoroscopic navigation in total hip arthroplasty (THA).

Methods

The first, postoperative, standing, anteroposterior pelvis radiographs from 1599 consecutive patients who underwent fluoroscopic-guided THAs via anterior approach during a six-year period were obtained. We retrospectively reviewed this prospectively collected data. Inclination and anteversion were measured as described by Barrack et al. Intraoperative target ranges for inclination and anteversion angles were 30°-50° and 5°-25°. Patients were divided into 3 cohorts by body mass index, nonobese (<30 kg/m2) obese (between 30 and 40 kg/m2) and morbidly obese (>40 kg/m2), looking for significant differences in acetabular component positioning.

Results

Of the 1599 patients, 1065 were nonobese, 506 obese, and 28 morbidly obese. Overall, average inclination was 37.7° and anteversion was 16.3°. Regarding inclination, 95.0% of cups were positioned in the safe zone, 95.7% for anteversion, and 91.2% for both inclination and anteversion. Analysis of each cohort individually revealed an average inclination of 37.5° in the nonobese, 37.9° in the obese, and 39.9° in the morbidly obese patients. For anteversion, each group's averages were 16.1°, 16.5°, and 16.0°, respectively. There was no significant relationship between a patient's body mass index and cup position for inclination (P = .867), anteversion (P = .673), or both inclination and anteversion (P = .624).

Conclusion

Fluoroscopy is a useful tool for achieving a targeted acetabular component orientation in direct anterior THA, irrespective of patient BMI.  相似文献   

20.

Background

Changes in spinal alignment and pelvic tilt alter acetabular orientation in predictable ways, which may have implications on stability of total hip arthroplasty (THA). Patients with sagittal spinal deformity represent a subset of patients who may be at particularly high risk of THA instability because of postural compensation for abnormal spinal alignment.

Methods

Using standing stereoradiography, we evaluated the spinopelvic parameters, acetabular cup anteversion, and inclination of 139 THAs in 107 patients with sagittal spinal deformity. Standing images were compared with supine pelvic radiographs to evaluate dynamic changes in acetabular cup position. Dislocation and revision rates were procured through retrospective chart review. The spinal parameters and acetabular cup positions among dislocators were compared with those who did not dislocate.

Results

The rate of THA dislocation in this cohort was 8.0%, with a revision rate of 5.8% for instability. Patients who sustained dislocations had significantly higher spinopelvic tilt, T1-pelvic angle, and mismatch of lumbar lordosis and pelvic incidence. Among all patients, 78% had safe anteversion while supine, which decreased significantly to 58% when standing due to increases in spinopelvic tilt. Among dislocating THA, 80% had safe anteversion, 80% had safe inclination, and 60% had both parameters within the safe zone.

Conclusion

In this cohort, patients with THA and concomitant spinal deformity have a particularly high rate of THA instability despite having an acetabular cup position traditionally thought of as within acceptable alignment. This dislocation risk may be driven by the degree of spinal deformity and by spinopelvic compensation. Surgeons should anticipate potential instability after hip arthroplasty and adjust their surgical plan accordingly.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号