首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
PURPOSE: Endoleak is a potential complication after endovascular repair of abdominal aortic aneurysm (AAA). It may result in continued growth of the aneurysm and potentially result in aneurysm rupture. The authors present their experience with embolotherapy in patients with persistent perigraft flow treated with the Ancure-Endovascular Technologies endograft system. MATERIALS AND METHODS: Between February 1996 and August 1998, 54 patients underwent successful repair of AAA with use of the Ancure system. All underwent operative angiography and discharge computed tomography (CT). Follow-up included CT at 6, 12, and 24 months, and CT was also performed at 3 months if an endoleak was present on the discharge CT. Persistent endoleak was defined as perigraft flow still present on the 6-month CT. Seven of 21 initial endoleaks persisted at 6 months. Six patients returned for embolization of the perigraft space and outflow vessels including lumbar arteries and the inferior mesenteric artery (IMA). RESULTS: Five of the six patients had leaks from the proximal (n = 1) or distal attachment sites (n = 4) of the Ancure system with outflow into lumbar arteries and/or the IMA; one leak was caused by retrograde IMA flow. The six patients underwent nine embolization procedures with only one minor complication. Follow-up CT showed complete resolution of endoleak and decrease in size of the aneurysm sac in all patients. CONCLUSIONS: Although endoleak is commonly seen initially with the Ancure system, persistent leak occurred in 13% of the patients in the study. Persistent flow in most patients arises from a graft attachment site combined with patent outflow vessels such as the IMA or lumbar arteries. Persistent endoleaks can be effectively and safely embolized with use of a combination of coil embolization of the perigraft space and embolization of outflow vessels. Such intervention resulted in a decrease in size of the aneurysm sac.  相似文献   

2.
A canine model for studying endoleak after endovascular aneurysm repair   总被引:2,自引:0,他引:2  
PURPOSE: The aim of this study was to create an animal model of endoleak after stent-graft placement for abdominal aortic aneurysm (AAA) in which a large aneurysmal sac would be preserved for the testing of techniques for its percutaneous occlusion. MATERIALS AND METHODS: Infrarenal AAAs were created in nine dogs by anastomosis of an isolated segment of the inferior vena cava to the right side of the abdominal aorta in combination with a large anterior patch from the external jugular vein. One hour later, animals underwent percutaneous implantation of polytetrafluoroethylene-covered Z stent endografts with three 3-mm-diameter holes through the fabric. Aortograms were obtained before and after surgery, after endograft placement, and at the time of animal sacrifice at 1 week or 1, 2, 3, or 6 months. Pressures within the aorta and the aneurysm sac were recorded before animal sacrifice. Gross and histologic evaluations of the specimens were then carried out. RESULTS: Immediately after endograft placement, all nine animals had artificial type III endoleaks with angiographic filling of lumbar arteries and veins. One animal died of surgical complications within 2 days of surgery and is not included in our data analysis. One aneurysm ruptured at 1 week. At completion of the study, six endografts were patent and two were occluded. The aneurysm sac had enlarged by approximately 50% in seven animals. At follow-up, type I endoleak was present in three animals, type II endoleak was present in three, and the artificial type III endoleak was present in all six animals with patent endografts. The pressure differential between aorta and aneurysm sac was 36 mm Hg, with a mean aortic pressure of 87 mm Hg +/- 13.3 and a mean aneurysmal sac pressure of 51 mm Hg +/- 28.1. The aneurysmal sac exhibited early thrombus formation at 1 week, which progressed to complete thrombosis in 1-6 months. CONCLUSIONS: The model is technically feasible but would be useful in testing occlusive techniques for residual aneurysm sacs only in the acute phase after endograft placement. It would be not reliable for chronic evaluation because of rapidly progressive thrombosis in most aneurysm sacs and occasional complete thrombosis of the AAA and endograft.  相似文献   

3.
PURPOSE: To determine the association of patent sac branch vessels (lumbar and inferior mesenteric arteries [IMAs]) with early endoleak rate after stent-graft repair of abdominal aortic aneurysm (AAA). MATERIALS AND METHODS: Pre- and postoperative computed tomographic (CT) angiograms in 158 patients who underwent stent-graft AAA repair were retrospectively reviewed to determine the preoperative patency of IMAs and other sac branch vessels (feeders) and presence or absence of immediate postoperative endoleak. Relationships of early endoleak rate with total branch vessel, IMA, and lumbar artery patency and graft type were evaluated. RESULTS: There was a significant association between patency of sac feeders and rate of early endoleak, especially type 2. As total patent feeders increased from zero to three to four to six, total endoleak rate increased from 6% (one of 17) to 35% (30 of 86); type 2 endoleak rate, from 0% to 25%. IMA patency was significantly associated with total early endoleak rate. Increasing lumbar artery patency also was associated with significantly higher total and type 2 endoleak rates: With zero to three lumbar arteries, the total endoleak rate was 17% and type 2 endoleak rate was 13%, as compared with 60% and 50%, respectively, with more than six patent lumbar arteries. CONCLUSION: Sac branch vessel patency is associated with significantly higher early total and type 2 endoleak rates after stent-graft repair of AAAs; thus, patent sac branches play an important role in the pathogenesis of endoleaks.  相似文献   

4.
PURPOSE: To evaluate the predictability of endoleak. MATERIALS AND METHODS: Thirteen women and 60 men (mean age, 69.8 years) underwent transfemoral insertion of endoluminal stent-grafts for treatment of aortic aneurysms. Follow-up included helical computed tomography (CT) at 3-month intervals. In the cases of endoleak, angiography also was performed to document the number of leak sites, their size and position, the feeding artery, the size of the aneurysm, the amount of thrombus, and the visualization of the lumbar arteries and inferior mesenteric artery. These data were correlated (Student t test) with the probability of endoleak. RESULTS: A total of seven (10%) endoleaks were identified at CT in 68 patients. The feeding vessels were lumbar arteries in three cases, the inferior mesenteric artery in three cases, and the median sacral artery in one case. Of all factors, only the number of lumbar arteries visualized preoperatively (P <.005) had a significant correlation with probability of endoleak. In 71% (five of seven patients) of the cases of lumbar endoleak, four lumbar arteries were patent, whereas among the 61 patients with successfully repaired aneurysm, only eight (13%) had four patent lumbar arteries. Endoleaks were never found in the primarily thrombosed sections of an aneurysm. CONCLUSION: Prediction of endoleaks with absolute certainty remains elusive. The single correlating risk factor identified from the data was patency of four or more lumbar arteries visualized preoperatively at CT.  相似文献   

5.
PURPOSE: To determine the spectrum and frequency of specific computed tomographic (CT) findings in the acute period after endovascular repair of abdominal aortic aneurysm (AAA). MATERIALS AND METHODS: CT images obtained 1--3 days after endograft placement were evaluated in 88 patients. The images were analyzed for stent position, appearance of endograft components, perigraft leak, and postoperative findings including air and acute thrombus within the aneurysm and air surrounding the femoral-femoral bypass graft. Findings that could be misinterpreted as perigraft leak were evaluated. RESULTS: Fifteen (17%) of 88 patients had perigraft leak in the acute postoperative period. The bare segment of the proximal self-expanding stent covered one or both renal arteries in 54 (61%) patients. One patient had CT evidence of renovascular compromise. Postoperative air was within the aneurysmal sac in 51 (58%) patients and surrounded the femoral-femoral bypass graft in 67 (94%) of 71 patients in whom the grafts were evaluated with CT. Mottled attenuation within the aneurysmal sac was seen in 50 (57%) patients. Forty-six (52%) patients had calcifications within longstanding thrombus. In 31 (35%) patients, findings that could have been misinterpreted as perigraft leak were identified. CONCLUSION: Accurate analysis of CT findings after endovascular AAA repair requires careful review of all available CT images (preprocedural and pre- and postcontrast) and clear understanding of specific stent-graft components and placement.  相似文献   

6.
《Radiologia》2016,58(3):235-238
This case presentation is about an 88 years-old male patient with previous endovascular aortic aneurysm repairment history and aortic endoleak type II (EL2). The direct lumbar artery catheterization was considered an alternative to solve EL2, associated with aortic endovascular prosthesis and due to an incomplete sealing or exclusion of the aneurysmal sac or a vascular segment demonstrated by imaging studies, when other treatment alternative failed (transarterial embolization) to control the aneurysm growing. Performing translumbar approach was decided by puncturing the artery lumbar (L4) left, previously the lumbar arteries (L4) were evaluated in the abdominal CT arterial phase to guide a puncture/access under flouroscopy control. Diagnostic angiogram clearly demonstrated the median sacral and right lumbar arteries inflow into the aneurysm sac. Transcatheter embolization with fibered platinum microcoils was performed of the median sacral artery and lumbar left and right arteries (L4), showing satisfactory endoleak devascularization.  相似文献   

7.
Radionuclide angiogram (RNA) and aortogram may underestimate external aneurysmal diameter. Photon deficient areas are not uncommon along the abdominal aortic aneurysm (AAA) on RNA. To determine whether or not photon deficient areas along the aneurysm could represent a large thrombus, we studied radionuclide aortic angiography in thirty-eight patients during a preoperative cardiac gated study. All the patients (men, ages from 60 to 78) had CT, US, and/or aortogram for comparison. The presence of a thrombus was determined by CT, US, and/or surgical findings. Twelve of 38 (32%) patients’ RNA and blood pool images showed photon deficient areas along the aneurysmal walls having a large concentric or eccentric thrombus of the AAA. A large photon deficient area could be detected along the narrowing calibre of the aorta lumen. This finding results from a large mural thrombus being interposed between the left or right bowel/mesentery activity and the activity of the aneurysms functioning patent lumen. We concluded that a photon deficient area along an inferorenal aortic aneurysm may indicate a large thrombus of either eccentric or concentric type within an AAA.  相似文献   

8.
目的:评价双源CT血管成像在腹主动脉瘤中的临床应用价值。方法:回顾性分析33例接受双源CT血管造影及主动脉造影检查确诊为腹主动脉瘤患者的影像资料。所有图像均行三维重建后处理及分析,观察腹主动脉瘤的部位、形态、分型、范围,并对腹主动脉瘤进行分型及相关测量。结果:33例腹主动脉瘤中,5例为近肾型,28例为肾下型。双源CT对瘤体长度、大小,近端及远端瘤颈长度、直径。近端瘤颈与动脉瘤长轴夹角测量准确。结论:双源CT可准确诊断腹主动脉瘤,并且可以提供详细而准确术前信息,是腹主动脉瘤术前诊断和术前评价的首选影像学检查方法。  相似文献   

9.
PurposeTo evaluate the influence of antiplatelet or anticoagulant therapy on sac behavior after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysm (AAA).Materials and MethodsThis study retrospectively analyzed data from patients with favorable neck anatomy who underwent EVAR between 2007 and 2019. Patients with ruptured AAA and ≤1 year of sac behavior evaluation were excluded. Sac shrinkage after 1 year, persistent type II endoleak, and late sac expansion were examined.ResultsIn total, 182 patients with favorable neck anatomy were included in this study. A multivariable analysis identified an occluded inferior mesenteric artery (IMA; P = .049), the presence of a posterior thrombus (P = .009), and no antiplatelet therapy (P = .012) as factors positively associated with sac shrinkage at 1 year. Persistent type II endoleak was detected in 56 (30.8%) patients, with patent IMA (P = .006), the lack of a posterior thrombus (P = .004), the number of patent lumbar arteries (P = .004), and antiplatelet therapy (P = .039) being identified as significant risk factors. The multivariable analysis identified a larger initial AAA diameter (P < .001), the lack of a posterior thrombus (P = .038), and antiplatelet and anticoagulant therapies (P = .038 and P = .003, respectively) as risk factors for late sac expansion.ConclusionsAfter EVAR in patients with favorable neck anatomy, antiplatelet therapy is associated with the lack of sac regression at 1 year, whereas antiplatelet and anticoagulant therapies are risk factors for late sac expansion.  相似文献   

10.
PURPOSE: To evaluate a new, low profile, home-made, bifurcated drum occluder endograft (BDOEG), designed for percutaneous, transcatheter treatment of abdominal aortic aneurysm (AAA). MATERIALS AND METHODS: AAA was created in 10 dogs with over-dilated Palmaz stents. To prevent back filling, the lumbar arteries, inferior mesenteric artery, and common internal iliac arteries were embolized. The BDOEG was constructed of a drum occluder device and two PTFE endografts. The drum device consisted of a modified Z stent with Dacron stretched across and held within the ends of the stent, each with two 8 x 6-mm slits through which PTFE endografts were delivered. The PTFE endografts were 8 mm in diameter and 9.5 cm in length. Preloaded, the BDOEG was delivered through a 10-F sheath from both femoral arteries in a three-step procedure. All 10 animals were treated with BDOEG. Aortography was performed immediately, 6 weeks, and 12 weeks after stent-graft placement. Five animals were killed at 6 weeks and five were killed at 3 months. Gross and histologic evaluation was performed. RESULTS: The infrarenal aortic diameters and both external iliac arteries ranged from 8.0 mm to 10.3 mm (mean, 9.4 mm +/- 0.6) and from 5.2 mm to 6.8 mm (mean, 5.8 mm +/- 0.5), respectively. Creation of the AAA was successful in all 10 dogs. AAA diameters ranged from 13.7 mm to 15.9 mm (mean, 14.9 mm +/- 0.7). Complete exclusion of the AAA was achieved immediately after BDOEG placement and aneurysms remained excluded without perigraft leak to the time of killing in all 10 animals. There was a high incidence of aortoiliac limb occlusion. Occlusion of 12 aortoiliac limbs (60%) caused by intimal hyperplasia at the distal end of the endografts in iliac arteries developed in nine animals (90%). In six animals (60%), one limb occluded and, in three animals (30%), there was occlusion of both limbs. CONCLUSION: This study suggests a new approach for treatment of AAA. BDOEG use reduces sheath size for endograft delivery and may eliminate the need for a surgical cut down on femoral arteries. Tapering of the iliac ends of endografts to the size of the artery will be needed to prevent distal intimal hyperplasia.  相似文献   

11.
王贵生  王宏  曾熔  齐连军 《武警医学》2003,14(10):603-606
 目的建立10只犬腹主动脉瘤模型,以介入法置入国产覆膜支架,观察其改变.方法10只实验动物建立模型;国产覆膜支架治疗后,CT进行影像学复查;最后取病理检查.结果两只发生并发症,余犬治疗后管腔通畅,但局部管腔有狭窄,病理电镜示覆膜支架内有内皮细胞生长.结论国产覆膜支架介入治疗腹主动脉瘤安全、有效.  相似文献   

12.
PURPOSE: To explore feasibility of twin-tube endografts (TTEGs) for treatment of abdominal aortic aneurysm (AAA). MATERIALS AND METHODS: AAAs were created in six dogs by overdilation of Palmaz stents. TTEGs made of seven 9.5-mm-diameter Gianturco R?sch Z (GRZ) stents and covered with PTFE were deployed simultaneously from both femoral arteries through 10-F sheaths to exclude the AAA. Follow-up aortography was performed immediately and at 2, 4, and 8 weeks. Two dogs were killed at 4 weeks and four were killed at 8 weeks. Gross and histologic examinations were performed. RESULTS: AAA creation and TTEG placement were successful in all six dogs. TTEGs completely excluded AAAs in five dogs. Minor temporary perigraft leak was seen in one dog immediately after stent placement. Four dogs had TTEGs patent to termination at 8 weeks. In two dogs with oversized TTEGs, one of the twin endografts occluded at 2 weeks. At autopsy, TTEGs were formed in semicircular shape and histology did not show any significant inflammatory reaction. CONCLUSION: TTEGs show promise for treatment of AAA, with the potential of reducing the introductory sheath size. Further experimental studies, particularly with TTEGs extended into iliac arteries, are warranted.  相似文献   

13.
PURPOSE: To evaluate the accuracy of CT images of abdominal aortic aneurysm (AAA) with volume-rendered (VR) display of vessel lumen and thrombus and to evaluate its usefulness in the planning of stent-grafting. MATERIALS AND METHODS: Helical CT was performed in 11 patients with AAA. Volume data of the vessel lumen and thrombus were separately extracted, and the VR images were reconstructed. Vessel measurements were made by five radiologists and compared with the axial and multiplanar reconstruction (MPR) images. Angiography and intravascular ultrasonography were used as standard references. The relations of aneurysmal sac to the major arterial branches and the subjective overall diagnostic value were evaluated by using a continuous rating scale. RESULTS: Accuracy of measurements was higher on VR images than on axial/MPR in 7 of 13 regions. Interobserver variance of VR images was smaller in 7 of 14 regions. Detection of renal and internal iliac artery involvements was better on VR images (p<0.05). Overall diagnostic value was also higher on VR images (p<0.05). CONCLUSION: VR CT images of vessel lumen and thrombus are supportive of and supplementary to conventional axial/MPR images in planning stent-grafting for AAA.  相似文献   

14.
Intra-luminal thrombus has been suggested to play a role in the progression of abdominal aortic aneurysm (AAA). The aims of this study were twofold. Firstly, to assess the reproducibility of a computer tomography (CT)-based technique for measurement of aortic thrombus volume. Secondly, to examine the determinants of infrarenal aortic thrombus volume in a cohort of patients with aortic dilatation. A consecutive series of 75 patients assessed by CT angiography with maximum aortic diameter >/=25 mm were recruited. Intra-luminal thrombus volume was measured by a semi-automated workstation protocol based on a previously defined technique to quantitate aortic calcification. Intra- and inter-observer reproducibility were assessed using correlation coefficients, coefficient of variation and Bland-Altman plots. Infrarenal aortic thrombus volume percentage was related to clinical, anatomical and blood characteristics of the patients using univariate and multivariate tests. Infrarenal aortic thrombus volume was related to the severity of aortic dilatation assessed by total aortic volume (r = 0.87, P < 0.0001) or maximum aortic diameter (r = 0.74, P < 0.0001). We therefore examined the clinical determinates of aortic thrombus expressed as a percentage of total aortic volume. Aortic thrombus percentage was negatively correlated with serum high density lipoprotein (HDL, r = -0.31). By ordinal multiple logistic regression analysis serum HDL below median (相似文献   

15.
The purpose of this study was to develop an abdominal aortic aneurysm model that more closely resembles the morphology of human aneurysms with potential for further growth of the sac. An infrarenal abdominal aortic aneurysm (AAA) model was created with a double-layered peritoneal patch in 27 domestic swine. The patch, measuring in average from 6 to 12 cm in length and from 2 to 3 cm in width, was sutured to the edge of an aortotomy. Pre- and postsurgical digital subtraction aortograms (DSA) were obtained to document the appearance and dimensions of the aneurysm. All animals were followed with DSA for up to 5 months. Laparoscopic examination enhanced by the use of laparoscopic ultrasound was also carried out in 2 animals to assess the aneurysm at 30 and 60 days following surgery. Histological examination was performed on 4 animals. All the animals that underwent the surgical creation of the AAA survived the surgical procedure. Postsurgical DSA demonstrated the presence of the AAA in all animals, defined as more than 50% increase in diameter. The aneurysmal mean diameter increased from the baseline of 10.27 ± 1.24 to 16.69 ± 2.29 mm immediately after surgery, to 27.6 ± 6.59 mm at 14 days, 32.45 ± 8.76 mm at 30 days (p < 0.01), and subsequently decreased to 25.98 ± 3.75 mm at 60 days. A total of 15 animals died of aneurysmal rupture that occurred more frequently in the long aneurysms (6 cm in length) than the short aneurysms (<6 cm in length) during the first 2 weeks after surgery (p < 0.05). No rupture occurred beyond 16 days after surgery. Four animals survived and underwent 60-day angiographic follow-up. Laparoscopic follow-up showed strong pulses, a reddish external appearance and undetectable suture lines on the aneurysmal wall. On pathology, the patches were well incorporated into the aortic wall, the luminal wall appeared almost completely endothelialized, and cellular and matrix proliferation were noted in the aneurysmal wall. A reproducible technique for the creation of an infrarenal AAA model was developed using a peritoneal patch in swine. The aneurysm model proved to have potential for further growth of the sac and a tendency to rupture. Because of the growth potential, this might be a better model than those with a noncompliant aneurysmal wall for the preclinical evaluation of stent-graft devices.  相似文献   

16.
腔内隔绝术治疗腹主动脉瘤(附2例报告)   总被引:2,自引:0,他引:2  
目的:探讨腔内隔绝术治疗腹主动脉瘤(AAA)的方法、疗效、并发症及存在的问题。方法:2例高龄、多病并存的AAA患者在全订及动脉造影的监控下,植入血管内支架-聚酯移植物复合体,对AAA进行腔内隔绝术。结果:术后定期复查彩超、CT及血管造影显示支架通畅,无移位、扭曲、支架外壁与瘤腔间充满血栓,未发现搏动的肠系膜下动脉及腰动脉,未发现渗漏。AAA外径无变化。患者腹部搏动性肿块消失。结论:腔内隔绝术治疗AAA避免了外科手术的各种缺点,具有简便、安全、疗效确定等优点。  相似文献   

17.
Complete aneurysm resolution is the hallmark of successful endoluminal stent-graft treatment. We describe 5 patients in whom an abdominal aortic aneurysm (AAA) disappeared completely at mid-term follow-up after endovascular stent-graft placement. We reviewed 45 patients (43 men and 2 women) who underwent AAA repair using an endovascular technique, from April 1997 to December 2001. Mean AAA diameter was 58.3 mm. On 48-month follow-up, 12 aneurysms had not changed in size, 4 had grown, 16 had shrunk, and 5 had resolved completely. We describe these 5 patients in detail. The 5 patients were all men, mean age 68 years; their mean aneurysmal sac diameter was 54 mm. The only common finding in all of them was patency of lumbar and inferior mesenteric arteries at pre-procedure evaluation as well as at follow-up. Mean time to complete resolution was 18 months. No major complications were encountered. AAA may resolve completely after endovascular stent-graft implantation. Patent side branches may perhaps contribute to AAA disappearance by antegrade flow. A larger patient population should be reviewed, however, before any statistical conclusion can be drawn.  相似文献   

18.
PURPOSE: To evaluate the usefulness of thoracic computed tomography (CT) after placement of an endovascular stent-graft for the treatment of descending thoracic aortic aneurysm. MATERIALS AND METHODS: From 1992 to 1996, 85 patients with thoracic aortic aneurysm underwent stent-graft placement. In 63 patients, thoracic CT scans were obtained both before and within 10 days after placement. The CT findings were retrospectively studied, and their clinical effect analyzed. In 20 of 63 patients, long-term follow-up CT findings were also evaluated. RESULTS: After stent-graft placement in the 63 patients, CT demonstrated an increase in pleural effusion in 46 (73%), periaortic changes in 21 (33%), perigraft leak in 13 (21%), atelectasis in six (10%), mural thrombus within the stent-graft in two (3%), and new aortic dissection in one (2%). The mean maximum diameter of the aneurysm was 58.8 mm before and 60.0 mm after stent-graft insertion. Sixty-two (98%) patients were successfully treated until discharge. Interventional procedures were performed to eliminate the leakage into the aneurysm sac in 10 patients with perigraft flow depicted at CT. Other complications were managed conservatively. CONCLUSION: Thoracic CT is useful in the treatment of patients after stent-graft insertion for the management of descending thoracic aortic aneurysm.  相似文献   

19.
PURPOSE: Perigraft flow--flow outside the graft lumen but contained within the abdominal aortic aneurysm (AAA)--is a potential complication after endovascular repair of AAA. Such flow may permit AAA growth and rupture. The purpose of this study is to evaluate with computed tomography (CT) the rate of spontaneous closure of perigraft flow and the effect of persistent flow on AAA diameter. MATERIALS AND METHODS: During a 30-month period, the authors evaluated all CT scans in 50 patients who underwent AAA repair using the Ancure endograft system. CT was performed at discharge, 6, 12, and 24 months, and at 3 months if there was perigraft flow at discharge. Scans were reviewed for the presence, size, and location of perigraft flow, and measurement of AAA diameter. Transcatheter embolization was performed on those patients with persistent leak at 6 months. RESULTS: Sixteen (32%) of 50 patients demonstrated perigraft flow on CT performed within 72 hours of placement. Resolution of perigraft flow by 6 months was found in nine (56%) of the 16 patients, in whom AAA size had decreased in five, had increased in none, and was unchanged in four. Seven patients had persistent leaks at 6-month CT; AAA size had decreased in one, had increased in one, and was unchanged in five. In 34 patients without leaks, AAA size had decreased in nine, had increased in one, and was unchanged on 24. There was no statistically significant difference for the relationship between resolution or persistence of perigraft flow and subsequent course of AAA diameter (P = .16). CONCLUSIONS: Although perigraft flow is frequently seen (32%) early after repair of AAA with the Ancure system, spontaneous resolution by 6 months occurs in 56% of cases. AAA size decreased in a larger percentage of patients in whom perigraft leak was absent or resolved by 6 months compared with those in whom perigraft leak persisted at 6 months.  相似文献   

20.

Purpose

To evaluate long-term efficacy of translumbar embolization of type II endoleaks exclusively supplied by the lumbar arteries in patients with growing abdominal aortic aneurysm sacs using N-butyl cyanoacrylate (NBCA) instilled via percutaneous needle access.

Materials and Methods

The study included 25 patients who developed type II endoleak after endovascular aneurysm repair. Inclusion criteria for intervention were defined as sac expansion > 5 mm detected with CT angiography at 6-month follow-up or later. Translumbar infusion of NBCA directly into the patent portion of the aneurysm sac was performed in all cases. Duplex US was performed the day after the intervention, and CT angiography was performed within the first month. Subsequently, duplex US was performed at 3, 6, and 9 months, and CT angiography or CT was performed at 12 months and annually thereafter.

Results

Translumbar embolization was achieved in all 25 patients. The endoleak resolved in 22 patients (88%) on duplex US performed 1 day after the embolization procedure. Three patients with persistent endoleak (12%) required repeat embolization. Two complications were detected and were managed conservatively.

Conclusions

This study demonstrates the safety and efficacy of NBCA injection for treatment of type II endoleaks. This technique provides another option for the management of type II endoleaks.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号