首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive and specific high-performance liquid chromatographic method with fluorescence detection (excitation wavelength: 280 nm; emission wavelength: 360 nm) was developed and validated for the determination of vinorelbine in plasma and blood samples. The sample pretreatment procedure involved two liquid-liquid extraction steps. Vinblastine served as the internal standard. The system uses a Spherisorb cyano analytical column (250x4.6 mm I.D.) packed with 5 microm diameter particles as the stationary phase and a mobile phase of acetonitrile-80 mM ammonium acetate (50:50, v/v) adjusted to pH 2.5 with hydrochloric acid. The assay showed linearity from 1 to 100 ng/ml in plasma and from 2.5 to 100 ng/ml in blood. The limits of quantitation were 1 ng/ml and 2.5 ng/ml, respectively. Precision expressed as RSD was in the range 3.9 to 20% (limit of quantitation). Accuracy ranged from 92 to 120%. Extraction recoveries from plasma and blood averaged 101 and 75%, respectively. This method was used to follow the time course of the concentration of vinorelbine in human plasma and blood samples after a 10-min infusion period of 20 mg/m2 of this drug in patients with metastatic cancer.  相似文献   

2.
A sensitive and specific high-performance liquid chromatographic-tandem mass spectrometric (HPLC-MS-MS) method was developed for the determination of 3-hydroxypropylmercapturic acid (3-HPMA) in human urine. Samples were extracted using ENV+ cartridges and then injected onto a C8 Superspher Select B column with acetonitrile and formic acid as eluent (5:95, v/v). N-Acetylcysteine was used as internal standard for HPLC-MS-MS. Linearity was given in the tested range of 50-5000 ng/ml urine. The limit of quantification was 50 ng/ml. Precision, as C.V., in the tested range of 50-5000 ng/ml was 1.47-6.04%. Accuracy ranged from 87 to 114%. 3-HPMA was stable in human urine at 37 degrees C for 24 h. The method was able to quantify 3-HPMA in urine of non-smokers and smokers.  相似文献   

3.
A fully automated high-performance liquid chromatography method with fluorescence detection for the determination of the renin inhibitor CGP 60536 in animal and human plasma and urine has been developed and validated. After addition of an internal standard, the compounds were automatically extracted from 400 microl of plasma or urine with methyl alcohol-acetic acid (99:1, v/v) on 100-mg Bond-Elut CN cartridges using the Gilson ASPEC system. The on-line chromatographic separation was performed on a LiChrospher 100 RP8 5-microm particle size packed analytical column (25x0.4 cm I.D.). The mobile phase consisted of acetonitrile-0.01 M potassium dihydrogenphosphate (65:35, v/v) at a flow-rate of 0.8 ml/min. The analytes were detected using a fluorescence detector at excitation and emission wavelengths of 280 and 330 nm, respectively. The limit of quantitation was established at 4.5 ng/ml in plasma (accuracy 106% and precision 1%), and 9.0 ng/ml in urine (accuracy 101% and precision 13%). The method was applied to the investigation of the pharmacokinetics of CGP 60536.  相似文献   

4.
A sensitive HPLC method for determination of bisphenol A (BPA) in plasma samples using 4-(4,5-diphenyl-1H-imidazol2-yl)benzoyl chloride (DIB-Cl) as a fluorescence labeling reagent was developed. The fluorescence labeling reaction was completed within 10 min at room temperature. DIB-Cl reacts with the phenolic hydroxyl group of BPA in the presence of triethylamine (TEA). The DIB-Cl derivative of BPA (DIB-BPA) was separated within 30 min with an ODS column using acetonitrile-water (90:10, v/v) as the isocratic eluent. Calibration graphs were linear over the range of 1.0-100 ng/ml (r=0.999). The detection limit of DIB-BPA was 0.05 ng/ml (2.5 pg) at a signal-to-noise ratio of 3. The relative standard deviations (RSDs) of the method for between-run were 1.0-5.0%. The analytical recoveries of known amounts (1.0 and 100 ng/ml) of BPA-spiked rabbit plasma were around 95%.  相似文献   

5.
A reversed-phase high-performance liquid chromatography method is described for the determination of oxybutynin (OXB) in human bladder samples. Following homogenization, tissue samples underwent double extraction with hexane and eventually were concentrated by freeze-drying before analysis. Chromatographic separation was performed with a mobile phase of acetonitrile-water-1 M ammonium acetate, pH 7.0 (85:13:2, v/v/v) at a flow-rate of 0.5 ml/min and double (electrochemical and UV) detection was applied. The retention time of oxybutynin eluting peak was around 18 min. Using a standard curve range of 10 to 500 ng/ml the quantification limit with electrochemical detection was 5 ng/ml with an injection volume of 100 microl. Within-day and day-to-day relative standard deviation values were 4.9 and 9.81%, respectively, while a 94% accuracy and a 72% recovery was attained. We applied this method to compare the OXB levels into bladder wall tissue samples after passive diffusion and after electromotive drug administration (EMDA), using a two-chambered poly(vinyl chloride) diffusion cell designed and developed in our laboratory. The results obtained show that EMDA enhanced OXB penetration into bladder wall and that this novel way of local drug administration can be potentially used in patients with neurogenic bladder dysfunction or urinary incontinence.  相似文献   

6.
A simple high-performance liquid chromatographic method using fluorescence detection was developed for the determination of vitamin E especially delta-, gamma- and alpha-tocotrienols in human plasma. The method entailed direct injection of plasma sample after deproteinization using a 3:2 mixture of acetonitrile-tetrahydrofuran. The mobile phase comprised 0.5% (v/v) of distilled water in methanol. Analyses were run at a flow-rate of 1.5 ml/min with the detector operating at an excitation wavelength of 296 nm and emission wavelength of 330 nm. This method is specific and sensitive, with a quantification limit of approximately 40, 34 and 16 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. The mean absolute recovery values were about 98% while the within-day and between-day relative standard deviation and percent error values of the assay method were all less than 12.0% for alpha-, gamma- and delta-tocotrienol. The calibration curve was linear over a concentration range of 40-2500, 30-4000 and 16-1000 ng/ml for alpha-, gamma- and delta-tocotrienol, respectively. Application of the method in a bioavailability study for determination of the above compounds was also demonstrated.  相似文献   

7.
A rapid, highly sensitive method for the determination of morphine and its metabolites morphine-3-glucuronide (M3G), morphine-6-glucuronide (M6G) and normorphine has been developed using high-performance liquid chromatography-electrospray mass spectrometry, with the deuterated analogues as internal standards. The analytes were extracted automatically using end-capped C2 solid-phase extraction cartridges. Baseline separation of morphine, M3G and M6G was achieved on a LiChrospher 100 RP-18 end-capped analytical column (125x3 mm I.D., 5 microm particle size) with water-acetonitrile-tetrahydrofuran-formic acid (100:1:1:0.1, v/v) as the mobile phase. Morphine and normorphine coeluate and were separated mass spectrometrically. The mass spectrometer was operated in the selected-ion monitoring mode using m/z 272 for normorphine, m/z 286 for morphine, m/z 462 for morphine-6-glucuronide. Due to an interfering peak, M3G was measured by tandem mass spectrometry in the daughter-ion mode. The limits of quantitation achieved with this method were 1.3 pmol/ml for morphine, 1.5 pmol/ml for normorphine, 1.0 pmol/ml for M6G and 5.4 pmol/ml for M3G in serum or cerebrospinal fluid. The limits of quantitation achieved in urine were 10 pmol/ml for morphine, 20 pmol/ml for normorphine and M6G and 50 pmol/ml for M3G using a sample size of 100 microl. The method described was successfully applied to the determination of morphine and its metabolites in human serum, cerebrospinal fluid and urine in pharmacokinetic and drug interaction studies.  相似文献   

8.
A liquid chromatographic method with photometric detection for the determination of cilazapril and its active metabolite and degradation product cilazaprilat in urine and pharmaceuticals has been developed. The chromatographic method consisted of a microBondapak C18 column maintained at 30+/-0.2 degrees C, using a mixture of methanol-10 mM phosphoric acid (50:50 v/v) as mobile phase at a flow-rate of 1.0 ml/min. Enalapril maleate was used as internal standard. The detection was performed at a wavelength of 206 nm. A study of the retention of cilazapril and cilazaprilat using solid-liquid extraction has been carried out in order to optimise the clean-up procedure for urine samples, which consisted of a solid-liquid extraction using C(R) cartridges. Recoveries greater than 85% are obtained for both compounds. The method was sensitive, precise and accurate enough to be applied to the determination of urine samples obtained from three hypertensive patients up to 24 h after intake of a therapeutic dose (detection limit of 70 ng/ml for cilazapril and cilazaprilat in urine). A comparison of the method developed using photometric and amperometric detection has been carried out.  相似文献   

9.
An optimized method for the determination of flecainide in serum is presented. Extraction using a solid-phase C18 column and chromatography on a stabilized fluorocarbon-bonded silica gel column effectively separate flecainide from an internal standard (a positional isomer of flecainide). The HPLC apparatus and conditions were as follows: analytical column, Fluofix 120N; sample solvent, 20 microl; column temperature, 40 degrees C; detector, Shimadzu RF-5000 fluorescence spectrophotometer (excitation wavelength = 300 nm, emission wavelength = 370 nm); mobile phase, 0.06% phosphoric acid containing 0.1% tetra-n-butyl ammonium bromide-acetonitrile (75:25, v/v); flow-rate, 1.0 ml/min. The standard curves for flecainide were linear in the concentration range examined (10-2000 ng/ml). The regression equation was y = 0.08+0.0078x (r = 0.9998). The minimum detectable amount of flecainide was approximately 5 ng/ml. In the within-day study, the precision coefficients of variation were 2.66, 2.18, 2.54, 2.72, 2.88, 2.24, and 3.29% for the 10, 50, 100, 200, 500, 1000, and 1500 ng/ml standards, respectively. The absolute recovery rates of flecainide at each concentrations were 94-100%. The method described provides analytical sensitivity, specificity and reproducibility suitable for both biomedical research and therapeutic drug monitoring.  相似文献   

10.
A modified high-performance chromatographic method using UV detection was developed for determination of tramadol concentration in human plasma. Plasma samples were extracted with ethyl acetate in a one-step liquid-liquid extraction (recovery 88.5+/-2.1%). Analysis of the extract was performed on a reversed-phase LiChrospher 60 RP-select B column with a particle size of 5 microm. The mobile phase consisted of 0.05 M KH2PO4 aqueous solution (pH 3.5) and acetonitrile in a ratio of 90:10 (v/v). Metoprolol was used as the internal standard and UV detection at 225 nm was employed. Accuracy of the assay in the concentration range examined was from 1.3 to 11.9% for the intra-day run and from 1.4 to 8.1% for the inter-day run. The precision of this method varied from 1.2 to 8.7%. The reproducibility of the method was determined to be from 0.8 to 7.2% over the six-day period. A limit of detection was 9 ng/ml at a signal-to-noise ratio of 3. This validated method was then applied to the determination of tramadol concentrations in healthy volunteers after oral administration of 100 mg of tramadol in capsules of Painlax and Tramal.  相似文献   

11.
A method for the determination of rofecoxib in human plasma is described. After the addition of an internal standard, buffered (pH 5) plasma samples are extracted with hexane-methylene chloride (50:50, v/v). The extracts are evaporated to dryness and reconstituted in mobile phase. Upon exposure to UV light, the analyte was found to undergo a stilbene-phenanthrene-like photocyclization reaction with the resulting formation of a highly fluorescent species. Thus, the plasma extracts were analyzed via HPLC with post-column photochemical derivatization and fluorescence detection. The assay has been validated in the concentration range of 0.5-100 ng/ml using 1-ml samples. The method has been successfully utilized to support human clinical pharmacokinetic studies.  相似文献   

12.
Determination of natural corticosteroids in urine samples from sportsmen   总被引:13,自引:0,他引:13  
A robust, fully automated assay procedure for the determination of rosiglitazone (I, BRL-49653) in human plasma has been developed. Plasma concentrations of I were determined using automated sequential trace enrichment of dialysates (ASTED) coupled to reversed-phase high-performance liquid chromatography. Sequential automated dialysis of human plasma samples was followed by concentration of the dialysate by trace enrichment on a C18 cartridge. Drug and internal standard, SB-204882 (II) were eluted from the trace enrichment cartridge by mobile phase (0.01 M ammonium acetate, pH 8-acetonitrile, 65:35, v/v) onto the HPLC column (a Novapak C18, 4 microm, 100x5 mm radial compression cartridge) protected by a Guard-Pak C18 cartridge. The compounds were detected by fluorescence detection, using an excitation wavelength of 247 nm, and emission wavelength of 367 nm. The lower limit of quantitation of the method was 3 ng/ml (200 microl aliquot) with linearity demonstrated up to 100 ng/ml. Within- and between-run precision and accuracy of determination were better than 10% across the calibration range. There was no evidence of instability of I in human plasma following three complete freeze-thaw cycles and samples can be safely stored for at least 7 months at -20 degrees C. This method has been successfully utilised to provide pharmacokinetic data throughout the clinical development of rosiglitazone.  相似文献   

13.
A HPLC method with automated column switching and UV detection is described for the simultaneous determination of retinol and major retinyl esters (retinyl palmitate, retinyl stearate, retinyl oleate and retinyl linoleate) in human plasma. Plasma (0.2 ml) was deproteinized by adding ethanol (1.5 ml) containing the internal standard retinyl propionate. Following centrifugation the supernatant was directly injected onto the pre-column packed with LiChrospher 100 RP-18 using 1.2% ammonium acetate-acetic acid-ethanol (80:1:20, v/v) as mobile phase. The elution strength of the ethanol containing sample solution was reduced by on-line supply of 1% ammonium acetate-acetic acid-ethanol (100:2:4, v/v). The retained retinol and retinyl esters were then transferred to the analytical column (Superspher 100 RP-18, endcapped) in the backflush mode and chromatographed under isocratic conditions using acetonitrile-methanol-ethanol-2-propanol (1:1:1:1, v/v) as mobile phase. Compounds of interest were detected at 325 nm. The method was linear in the range 2.5-2000 ng/ml with a limit of quantification for retinol and retinyl esters of 2.5 ng/ml. Mean recoveries from plasma were 93.4-96.5% for retinol (range 100-1000 ng/ml) and 92.7-96.0% for retinyl palmitate (range 5-1000 ng/ml). Inter-assay precision was < or =5.1% and < or =6.3% for retinol and retinyl palmitate, respectively. The method was successfully applied to more than 2000 human plasma samples from clinical studies. Endogenous levels of retinol and retinyl esters determined in female volunteers were in good accordance with published data.  相似文献   

14.
We have developed and validated a sensitive and selective method for the determination of the P-glycoprotein modulator GF120918 in murine and human plasma. Chlorpromazine is used as internal standard. Sample pretreatment involves liquid-liquid extraction with tert-butyl methyl ether. Chromatographic separation is achieved by reversed-phase high-performance liquid chromatography using a Symmetry C18 column and detection was accomplished with a fluorescence detector set at excitation and emission wavelengths of 260 and 460 nm, respectively. The mobile phase consists of acetonitrile-50 mM ammonium acetate buffer, pH 4.2 (35:65, v/v). To achieve good separation from endogenous compounds and to improve the peak shape the counter-ion 1-octane sulfonic acid (final concentration 0.005 M) was added to the mobile phase. The lower limit of quantitation was 5.7 ng/ml using 200 microl of human plasma and 23 ng/ml using 50 microl of murine plasma. Within the dynamic range of the calibration curve (5.7-571 ng/ml) the accuracy was close to 100% and within-day and between-day precision were within the generally accepted 15% range. The stability of GF120918 was tested in plasma and blood from mice and humans incubated at 4 degrees C, room temperature, and 37 degrees C for up to 4 h. No losses were observed under these conditions. This method was applied to study the pharmacokinetics of orally administered GF120918 in humans and mice. The sensitivity of the assay was sufficient to determine the concentration in plasma samples obtained up to 24 h after drug administration.  相似文献   

15.
Olanzapine is a commonly used atypical antipsychotic medication for which therapeutic drug monitoring has been proposed as clinically useful. A sensitive method was developed for the determination of olanzapine concentrations in plasma and urine by high-performance liquid chromatography with low-wavelength ultraviolet absorption detection (214 nm). A single-step liquid-liquid extraction procedure using heptane-iso-amyl alcohol (97.5:2.5 v/v) was employed to recover olanzapine and the internal standard (a 2-ethylated olanzapine derivative) from the biological matrices which were adjusted to pH 10 with 1 M carbonate buffer. Detector response was linear from 1-5000 ng (r2>0.98). The limit of detection of the assay (signal:noise=3:1) and the lower limit of quantitation were 0.75 ng and 1 ng/ml of olanzapine, respectively. Interday variation for olanzapine 50 ng/ml in plasma and urine was 5.2% and 7.1% (n=5), respectively, and 9.5 and 12.3% at 1 ng/ml (n=5). Intraday variation for olanzapine 50 ng/ml in plasma and urine was 8.1% and 9.6% (n=15), respectively, and 14.2 and 17.1% at 1 ng/ml (n=15). The recoveries of olanzapine (50 ng/ml) and the internal standard were 83 +/- 6 and 92 +/- 6% in plasma, respectively, and 79 +/- 7 and 89 +/- 7% in urine, respectively. Accuracy was 96% and 93% at 50 and 1 ng/ml, respectively. The applicability of the assay was demonstrated by determining plasma concentrations of olanzapine in a healthy male volunteer for 48 h following a single oral dose of 5 mg olanzapine. This method is suitable for studying olanzapine disposition in single or multiple-dose pharmacokinetic studies.  相似文献   

16.
A sensitive chromatographic assay has been developed for m-iodobenzylguanidine (MIBG) in human plasma based on the derivatization with benzoin. MIBG is first isolated from plasma using solid-phase extraction on a cyanopropyl-modified silica phase. After evaporation of the eluate, a fluorescent derivative is formed using benzoin. The derivative is analysed by reversed-phase liquid chromatography using a mixture 60% (v/v) acetonitrile, 30% (v/v) water and 10% (v/v) of the 0.5 M Tris buffer (pH 8.0) as the eluent and fluorescence detection at 320 nm for excitation and 435 nm for emission, respectively. In the evaluated concentration range (2-200 ng/ml) precisions < or = 10% and accuracies in between 90 and 100% have been found, with 2 ng/ml being the lower limit of quantification using a 0.5-ml plasma sample volume. The assay can also be used without the internal standard benzylguanidine. The assay was successfully used to obtain a pharmacokinetic curve of MIBG.  相似文献   

17.
A high-performance liquid chromatographic assay with UV detection has been developed for the determination of ketoconazole in human plasma. Quantitative extraction was achieved by a single solvent extraction involving a mixture of acetonitrile-n-butyl chloride (1:4, v/v). Ketoconazole and the internal standard (clotrimazole) were separated on a column packed with Inertsil ODS-80A material and a mobile phase composed of water-acetonitrile-tetrahydrofuran-ammonium hydroxide-triethylamine (45:50.2:2.5:0.1:0.1, v/v). The column effluent was monitored at a wavelength of 206 nm with a detector range set at 0.5. The calibration graph was linear in the range of 20-2000 ng/ml, with a lower limit of quantitation of 20.0 ng/ml. The extraction recoveries for ketoconazole and clotrimazole in human plasma were 93+/-9.7% and 83+/-10.0%, respectively. The developed method has been successfully applied to a clinical study to examine the pharmacokinetics of ketoconazole in a cancer patient.  相似文献   

18.
A rapid, selective and very sensitive ion-pairing reversed-phase HPLC method was developed for the simultaneous determination of trimebutine (TMB) and its major metabolite, N-monodesmethyltrimebutine (NDTMB), in rat and human plasma. Heptanesulfonate was employed as the ion-pairing agent and verapamil was used as the internal standard. The method involved the extraction with a n-hexane-isopropylalcohol (IPA) mixture (99:1, v/v) followed by back-extraction into 0.1 M hydrochloric acid and evaporation to dryness. HPLC analysis was carried out using a 4-microm particle size, C18-bonded silica column and water-sodium acetate-heptanesulfonate-acetonitrile as the mobile phase and UV detection at 267 nm. The chromatograms showed good resolution and sensitivity and no interference of plasma. The mean recoveries for human plasma were 95.4+/-3.1% for TMB and 89.4+/-4.1% for NDTMB. The detection limits of TMB and its metabolite, NDTMB, in human plasma were 1 and 5 ng/ml, respectively. The calibration curves were linear over the concentration range 10-5000 ng/ml for TMB and 25-25000 ng/ml for NDTMB with correlation coefficients greater than 0.999 and with within-day or between-day coefficients of variation not exceeding 9.4%. This assay procedure was applied to the study of metabolite pharmacokinetics of TMB in rat and the human.  相似文献   

19.
A rapid and sensitive high-performance liquid chromatographic method for determination of nimesulide in human plasma has been developed. The chromatographic system uses a reversed-phase C18 column with UV-Vis detection at 230 nm. Mobile-phase consisted of phosphate buffer (pH 5.5)-methanol-acetonitrile (50:20:30, v/v) at a flow-rate of 1.4 ml/min. Nimesulide was extracted in a single step into dichloromethane.The overall mean extraction recoveries were above 98% for both inter- and intra-assay reproducibility, with CVs from 0.3 to 1%. The calibration curve was linear in the concentration range of 0.05-5 microg/ml, and the lower limit of detection was 30 ng/ml. This simple and sensitive method allows for determination of the range of plasma concentrations that is observed after administration of clinically relevant doses of nimesulide.  相似文献   

20.
A simple high-performance liquid chromatographic method was developed for the determination of vanillin and its vanillic acid metabolite in human plasma, red blood cells and urine. The mobile phase consisted of aqueous acetic acid (1%, v/v)-acetonitrile (85:15, v/v), pH 2.9 and was used with an octadecylsilane analytical column and ultraviolet absorbance detection. The plasma method demonstrated linearity from 2 to 100 microg/ml and the urine method was linear from 2 to 40 microg/ml. The method had a detection limit of 1 microg/ml for vanillin and vanillic acid using 5 microl of prepared plasma, red blood cells or urine. The method was utilized in a study evaluating the pharmacokinetic and pharmacodynamic effects of vanillin in patients undergoing treatment for sickle cell anemia.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号