首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

Bioprosthetic aortic valve degeneration is increasingly common, often unheralded, and can have catastrophic consequences.

Objectives

The authors sought to assess whether 18F-fluoride positron emission tomography (PET)-computed tomography (CT) can detect bioprosthetic aortic valve degeneration and predict valve dysfunction.

Methods

Explanted degenerate bioprosthetic valves were examined ex vivo. Patients with bioprosthetic aortic valves were recruited into 2 cohorts with and without prosthetic valve dysfunction and underwent in vivo contrast-enhanced CT angiography, 18F-fluoride PET, and serial echocardiography during 2 years of follow-up.

Results

All ex vivo, degenerate bioprosthetic valves displayed 18F-fluoride PET uptake that colocalized with tissue degeneration on histology. In 71 patients without known bioprosthesis dysfunction, 14 had abnormal leaflet pathology on CT, and 24 demonstrated 18F-fluoride PET uptake (target-to-background ratio 1.55 [interquartile range (IQR): 1.44 to 1.88]). Patients with increased 18F-fluoride uptake exhibited more rapid deterioration in valve function compared with those without (annualized change in peak transvalvular velocity 0.30 [IQR: 0.13 to 0.61] vs. 0.01 [IQR: ?0.05 to 0.16] ms?1/year; p < 0.001). Indeed 18F-fluoride uptake correlated with deterioration in all the conventional echocardiographic measures of valve function assessed (e.g., change in peak velocity, r = 0.72; p < 0.001). Each of the 10 patients who developed new overt bioprosthesis dysfunction during follow-up had evidence of 18F-fluoride uptake at baseline (target-to-background ratio 1.89 [IQR: 1.46 to 2.59]). On multivariable analysis, 18F-fluoride uptake was the only independent predictor of future bioprosthetic dysfunction.

Conclusions

18F-fluoride PET-CT identifies subclinical bioprosthetic valve degeneration, providing powerful prediction of subsequent valvular dysfunction and highlighting patients at risk of valve failure. This technique holds major promise in the diagnosis of valvular degeneration and the surveillance of patients with bioprosthetic valves. (18F-Fluoride Assessment of Aortic Bioprosthesis Durability and Outcome [18F-FAABULOUS]; NCT02304276)  相似文献   

2.
3.
4.
BackgroundBioprosthetic valve thrombosis may have implications for valve function and durability.ObjectivesUsing a novel glycoprotein IIb/IIIa receptor radiotracer 18F-GP1, we investigated whether positron emission tomography (PET)-computed tomography (CT) could detect thrombus formation on bioprosthetic aortic valves.MethodsEx vivo experiments were performed on human platelets and explanted bioprosthetic aortic valves. In a prospective cross-sectional study, patients with either bioprosthetic or normal native aortic valves underwent echocardiography, CT angiography, and 18F-GP1 PET-CT.ResultsFlow cytometric analysis, histology, immunohistochemistry, and autoradiography demonstrated selective binding of 18F-GP1 to activated platelet glycoprotein IIb/IIIa receptors and thrombus adherent to prosthetic valves. In total, 75 participants were recruited: 53 with bioprosthetic valves (median time from implantation 37 months [IQR: 12-80 months]) and 22 with normal native aortic valves. Three participants had obstructive valve thrombosis, and a further 3 participants had asymptomatic hypoattenuated leaflet thickening on CT angiography. All bioprosthetic valves, but none of the native aortic valves, demonstrated focal 18F-GP1 uptake on the valve leaflets: median maximum target-to-background ratio 2.81 (IQR: 2.29-3.48) vs 1.43 (IQR: 1.28-1.53) (P < 0.001). Higher 18F-GP1 uptake was independently associated with duration of valve implantation and hypoattenuated leaflet thickening. All 3 participants with obstructive valve thrombosis were anticoagulated for 3 months, leading to resolution of their symptoms, improvement in mean valve gradients, and a reduction in 18F-GP1 uptake.ConclusionsAdherence of activated platelets is a common and sustained finding on bioprosthetic aortic valves. 18F-GP1 uptake is higher in the presence of thrombus, regresses with anticoagulation, and has potential use as an adjunctive clinical tool. (18F-GP1 PET-CT to Detect Bioprosthetic Aortic Valve Thrombosis; NCT04073875)  相似文献   

5.
BackgroundEarly in the prevention and treatment of bioprosthetic valve thrombosis (BPVT), anticoagulation is effective, but the long-term outcome after BPVT is unknown.ObjectivesThe goal of this study was to assess the long-term outcomes of patients with BPVT treated with anticoagulation.MethodsThis analysis was a matched cohort study of patients treated with warfarin for suspected BPVT at the Mayo Clinic between 1999 and 2017.ResultsA total of 83 patients treated with warfarin for suspected BPVT (age 57 ± 18 years; 45 men [54%]) were matched to 166 control subjects; matching was performed according to age, sex, year of implantation, and prosthesis type and position. Echocardiography normalized in 62 patients (75%) within 3 months (interquartile range [IQR]: 1.5 to 6 months) of anticoagulation; 21 patients (25%) did not respond to warfarin. Median follow-up after diagnosis was 34 months (IQR: 17 to 54 months). There was no difference in the primary composite endpoint between the patients with BPVT and the matched control subjects (log-rank test, p = 0.79), but the former did have a significantly higher rate of major bleeding (12% vs. 2%; p < 0.0001). BPVT recurred (re-BPVT) in 14 (23%) responders after a median of 23 months (IQR: 11 to 39 months); all but one re-BPVT patient responded to anticoagulant therapy. Patients with BPVT had a higher probability of valve re-replacement (68% vs. 24% at 10 years’ post-BPVT; log-rank test, p < 0.001).ConclusionsBPVT was associated with re-BPVT and early prosthetic degeneration in a significant number of patients. Indefinite warfarin anticoagulation should be considered after a confirmed BPVT episode, but this strategy must be balanced against an increased risk of bleeding.  相似文献   

6.
7.
8.
BackgroundPre-procedural chronic kidney disease (CKD) and in-hospital acute kidney injury (AKI) are associated with worse outcomes following transcatheter aortic valve replacement (TAVR). We tested the feasibility of reducing overall AKI by avoiding pre-procedural cardiac CT angiography (CCTA) by using direct 3D-TEE guidance in TAVR patients with known CKD.MethodsAn institutional TAVR database was examined from January 2016 to June 2020 to identify 396 patients in whom CCTA sizing was performed and 54 patients with creatinine (Cr) of >1.6 mg/dL in whom direct 3D-TEE, without prior CCTA, was used for TAVR guidance. Baseline demographics, procedural, echocardiographic, and clinical endpoints were compared as defined by the Valve Academic Research Consortium-2 criteria.ResultsBaseline demographics and risk factors were similar in both groups other than the creatinine level in CCTA vs. TEE groups (1.33 ± 1.1 vs 1.76 ± 0.7 mg/dL, p = 0.005). Procedural contrast volume was significantly lower in the TEE group compared to the CCTA group. No differences were noted in echocardiographic and clinical endpoints for both groups. Despite higher baseline Cr, patents in the TEE group experienced a similar pattern of changes in Cr compared to the CCTA group, with an overall renal improvement noted at the time of discharge for both groups.ConclusionsIn patients with baseline CKD, careful avoidance of large contrast loads associated with CCTA and intra-procedural aortography by using TEE guidance may help reduce AKI following TAVR.  相似文献   

9.
10.
11.

Background

Surgical aortic valve replacement using conventional biological valves (CBVs) is the standard of care for treatment of old patients with aortic valve disease. Recently, rapid deployment valves (RDVs) have been introduced.

Objectives

The purpose of this study was to report the nationwide German experience concerning RDVs for treatment of aortic valve stenosis and provide a head-to-head comparison with CBVs.

Methods

A total of 22,062 patients who underwent isolated surgical aortic valve replacement using CBV or RDV between 2011 and 2015 were enrolled into the German Aortic Valve Registry. Baseline, procedural, and in-hospital outcome parameters were analyzed for CBVs and RDVs using 1:1 propensity score matching. Furthermore, 3 RDVs were compared with each other.

Results

A total of 20,937 patients received a CBV, whereas 1,125 patients were treated with an RDV. Patients treated with an RDV presented with significantly reduced procedure (160 min [25th to 75th percentile: 135 to 195 min] vs. 150 min [25th to 75th percentile: 127 to 179 min]; p < 0.001), cardiopulmonary bypass (83 min [25th to 75th percentile: 68 to 104 min] vs. 70 min [25th to 75th percentile: 56 to 87 min]; p < 0.001), and aortic cross clamp times (60 min [25th to 75th percentile: 48 to 75 min] vs. 44 min [25th to 75th percentile: 35 to 57 min]; p < 0.001), but showed significantly elevated rates of pacemaker implantation (3.7% vs. 8.8%; p < 0.001) and disabling stroke (0.9% vs. 2.2%; p < 0.001), whereas in-hospital mortality was similar (1.7% vs. 2.2%; p = 0.22). These findings persisted after 1:1 propensity score matching. Comparison of the 3 RDVs revealed statistically nonsignificant different pacemaker rates and significantly different post-operative transvalvular gradients.

Conclusions

In this large, all-comers database, the incidence of pacemaker implantation and disabling stroke was higher with RDVs, whereas no beneficial effect on in-hospital mortality was seen. The 3 RDVs presented different complication profiles with regard to pacemaker implantation and transvalvular gradients. (German Aortic Valve Registry [GARY]; NCT01165827)  相似文献   

12.
13.
14.
Doppler echocardiography and color flow imaging are helpful techniques in evaluating the functional status of a bioprosthetic valve. The aim of this study was to determine whether serial Doppler gradients are predictive of future bioprosthetic valve degeneration. We performed serial echo-Doppler studies over a 6-year period (1988–1994) on 228 patients who had undergone mitral (n = 112) or aortic (n = 116) bioprosthetic valve implantation between 1973 and 1994. Thirtynine mitral prostheses and 30 aortic prostheses became dysfunctional and required reoperation. A serial rise in mean gradient of 5 mmHg or more across the mitral valve and 25 mmHg or more across the aortic valve was significantly associated with increased valve degeneration (odds ratio 3.40 and 16.11 and 95% confidence intervals 1.31 and 8.80 and 13.6 and 72.13 for the mitral and aortic valve, respectively). Both aortic and mitral valves began to degenerate after 8 years. Serial echo-Doppler studies showed a rise in transvalvular gradients around the same time. Closer evaluation for prosthetic valve dysfunction should be considered in patients 8 or more years status post surgery, especially those with high transvalvular gradients.  相似文献   

15.
16.
17.
ObjectivesThe aim of this study was to examine the predictive value of preprocedural computed tomography (CT)–based risk stratification of coronary obstruction during transcatheter aortic valve replacement (TAVR) on the basis of geometric measurements on postprocedural CT.BackgroundProper patient selection for additional procedures to prevent coronary obstruction during TAVR has not been adequately evaluated.MethodsPre- and postprocedural computed tomographic scans of 28 patients treated using bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) and TAVR were analyzed. Using the postprocedural computed tomographic images, threatened coronary obstruction (TCO) was defined as: 1) ostial obstruction (adherence of the transcatheter heart valve [THV] to the coronary ostium with leaflet extension above the ostium); and/or 2) sinus sequestration (THV adherence to the sinotubular junction [STJ] with leaflet extension above the STJ) and was substratified into complete and incomplete types.ResultsA total of 51 leaflets were evaluated (88% surgical tissue valves) after excluding leaflets not visible on CT (n = 5). On postprocedural CT, complete TCO was observed in 25.4% (13 of 51 leaflets). On preprocedural CT, leaflets were at high risk for complete TCO (incidence 53%) if the virtual THV–to–coronary distance (VTC) was <3.0 mm, or if the virtual THV–to–STJ distance (VTSTJ) was <1.0 mm with STJ height ? leaflet length <0 mm (leaflet-STJ mismatch). Leaflets were at low risk (incidence 0%) if the VTC was ≥3 mm and VTSTJ was ≥3.0 mm or STJ height ? leaflet length was ≥+2.0 mm. Of 28 leaflets treated using BASILICA, complete TCO was seen in 35.7% (n = 10), due to sinus sequestration (100%) with coexisting ostial obstruction (30%). Actual coronary events occurred in 7.1% (n = 2) because of leaflet prolapse, corresponding to an absolute risk reduction by BASILICA of 29% (P = 0.021).ConclusionsRisk assessment of coronary obstruction after TAVR may improve with a multiparametric approach incorporating VTC, VTSTJ, and leaflet-STJ mismatch. BASILICA appeared to reduce actual coronary events even in leaflets with anticipated coronary obstruction.  相似文献   

18.
19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号