首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ObjectivesThe aim of this study was to assess acute regurgitation following transcatheter aortic valve replacement, comparing different implanted transcatheter heart valves.BackgroundRegurgitation following transcatheter aortic valve replacement influences all-cause mortality. Thus far, no quantitative comparison of regurgitation among multiple commercially available transcatheter heart valves has been performed.MethodsAortograms from a multicenter cohort of consecutive 3,976 transcatheter aortic valve replacements were evaluated in this pooled analysis. A total of 2,258 (58.3%) were considered analyzable by an independent academic core laboratory using video densitometry. Results of quantitative regurgitation are shown as percentages. The valves evaluated were the ACURATE (n = 115), Centera (n = 11), CoreValve (n = 532), Direct Flow Medical (n = 21), Evolut PRO (n = 95), Evolut R (n = 295), Inovare (n = 4), Lotus (n = 546), Lotus Edge (n = 3), SAPIEN XT (n = 239), and SAPIEN 3 (n = 397). For the main analysis, only valves with more than 50 procedures (7 types) were used.ResultsThe Lotus valve had the lowest mean regurgitation (3.5 ± 4.4%), followed by Evolut PRO (7.4 ± 6.5%), SAPIEN 3 (7.6 ± 7.1%), Evolut R (7.9 ± 7.4%), SAPIEN XT (8.8 ± 7.5%), ACURATE (9.6 ± 9.2%) and CoreValve (13.7 ± 10.7%) (analysis of variance p < 0.001). The only valves that statistically differed from all their counterparts were Lotus (as the lowest regurgitation) and CoreValve (the highest). The proportion of patients presenting with moderate or severe regurgitation followed the same ranking order: Lotus (2.2%), Evolut PRO (5.3%), SAPIEN 3 (8.3%), Evolut R (8.8%), SAPIEN XT (10.9%), ACURATE (11.3%), and CoreValve (30.1%) (chi-square p < 0.001).ConclusionsIn this pooled analysis stemming from daily clinical practice, the Lotus valve was shown to have the best immediate sealing. This analysis reflects the objective evaluation of regurgitation by an academic core laboratory (nonsponsored) in a real-world cohort of patients using a quantitative technique.  相似文献   

2.
ObjectivesThis study sought to determine the incidence, clinical impact, and changes over time of mitral regurgitation (MR) in patients with low-flow, low-gradient aortic stenosis (LFLG-AS) undergoing transcatheter aortic valve replacement (TAVR).BackgroundFew data exist on the clinical impact and changes in severity over time of MR in patients with LFLG-AS undergoing TAVR.MethodsA total of 308 TAVR candidates with LFLG-AS were included. Patients were categorized according to MR severity at baseline, and presence of MR improvement at 12-month follow-up. Clinical outcomes were assessed at 1 and 12 months (+ echocardiography), and yearly thereafter.ResultsBaseline mild and moderate-to-severe MR were present in 118 (38.3%) and 115 (37.3%) patients, respectively. MR was of functional and mixed etiology in 77.2% and 22.7% of patients, respectively. A total of 131 patients (42.5%) died after a median follow-up of 2 (1 to 3) years. Baseline moderate-or-greater MR had no impact on mortality (hazard ratio [HR]: 1.34; 95% confidence interval [CI]: 0.72 to 2.48) or heart failure hospitalization (HR: 1.02; 95% CI: 0.49 to 2.10). At 1-year follow-up, MR improved in 44.3% of patients and remained unchanged/worsened in 55.7%. The lack of MR improvement was associated with a higher risk of all-cause and cardiac mortality (HR: 2.02; 95% CI: 1.29 to 3.17; HR: 3.03; 95% CI: 1.27 to 7.23, respectively), rehospitalization for cardiac causes (HR: 1.50; 95% CI: 1.04 to 2.15), and an increased overall-mortality/heart failure rehospitalization (HR: 1.94; 95% CI: 1.25 to 3.02). A higher baseline left ventricular end-diastolic diameter and a higher increase in left ventricular ejection fraction were found to be independent predictors of MR improvement at 1-year follow-up (odds ratio: 0.69; 95% CI: 0.51 to 0.94; and odds ratio: 0.81; 95% CI: 0.67 to 0.96, respectively).ConclusionsMost TAVR candidates with LFLG-AS had some degree of MR, of functional origin in most cases. MR improved in about one-half of patients, with larger left ventricular size and a higher increase in left ventricular ejection fraction post-TAVR determining MR improvement over time. The lack of MR improvement at 1 year was associated with poorer outcomes.  相似文献   

3.
BackgroundThe extent of extravalvular cardiac damage is associated with increased risk of adverse events among patients with severe aortic stenosis undergoing aortic valve replacement (AVR).ObjectivesThe goal was to describe the association of cardiac damage on health status before and after AVR.MethodsPatients from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were pooled and classified by echocardiographic cardiac damage stage at baseline and 1 year as previously described (stage 0-4). We examined the association between baseline cardiac damage and 1-year health status (assessed by the Kansas City Cardiomyopathy Questionnaire Overall Score [KCCQ-OS]).ResultsAmong 1,974 patients (794 surgical AVR, 1,180 transcatheter AVR), the extent of cardiac damage at baseline was associated with lower KCCQ scores both at baseline and at 1 year after AVR (P < 0.0001) and with increased rates of a poor outcome (death, KCCQ-OS <60, or a decrease in KCCQ-OS of ≥10 points) at 1 year (stages 0-4: 10.6% vs 19.6% vs 29.0% vs 44.7% vs 39.8%; P < 0.0001). In a multivariable model, each 1-stage increase in baseline cardiac damage was associated with a 24% increase in the odds of a poor outcome (95% CI: 9%-41%; P = 0.001). Change in stage of cardiac damage at 1 year after AVR was associated with the extent of improvement in KCCQ-OS over the same period (mean change in 1-year KCCQ-OS: improvement of ≥1 stage +26.8 [95% CI: 24.2-29.4] vs no change +21.4 [95% CI: 20.0-22.7] vs deterioration of ≥1 stage +17.5 [95% CI: 15.4-19.5]; P < 0.0001).ConclusionsThe extent of cardiac damage before AVR has an important impact on health status outcomes, both cross-sectionally and after AVR. (PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - XT Intermediate and High Risk (PII A), NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII B [PARTNERII B], NCT02184442; PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [P3], NCT02675114)  相似文献   

4.
ObjectivesThe aim of this study was to describe baseline characteristics, and periprocedural and mid-term outcomes of patients undergoing transcatheter mitral valve interventions post-transcatheter aortic valve replacement (TAVR) and examine their clinical benefit.BackgroundThe optimal management of residual mitral regurgitation (MR) post-TAVR is challenging.MethodsThis was an international registry of 23 TAVR centers.ResultsIn total, 106 of 24,178 patients (0.43%) underwent mitral interventions post-TAVR (100 staged, 6 concomitant), most commonly percutaneous edge-to-edge mitral valve repair (PMVR). The median interval post-TAVR was 164 days. Mean age was 79.5 ± 7.2 years, MR was >moderate in 97.2%, technical success was 99.1%, and 30-day device success rate was 88.7%. There were 18 periprocedural complications (16.9%) including 4 deaths. During a median follow-up of 464 days, the cumulative risk for 3-year mortality was 29.0%. MR grade and New York Heart Association (NYHA) functional class improved dramatically; at 1 year, MR was moderate or less in 90.9% of patients (mild or less in 69.1%), and 85.9% of patients were in NYHA functional class I/II. Staged PMVR was associated with lower mortality versus medical treatment (57.5% vs. 30.8%) in a propensity-matched cohort (n = 156), but this was not statistically significant (hazard ratio: 1.75; p = 0.05).ConclusionsFor patients who continue to have significant MR, remain symptomatic post-TAVR, and are anatomically suitable for transcatheter interventions, these interventions are feasible, safe, and associated with significant improvement in MR grade and NYHA functional class. These results apply mainly to PMVR. A staged PMVR strategy was associated with markedly lower mortality, but this was not statistically significant. (Transcatheter Treatment for Combined Aortic and Mitral Valve Disease. The Aortic+Mitral TRAnsCatheter Valve Registry [AMTRAC]; NCT04031274)  相似文献   

5.
ObjectivesThis study sought to evaluate the association between severity of left ventricular hypertrophy (LVH) before transcatheter aortic valve replacement (TAVR) and outcomes out to 5 years.BackgroundPrior studies assessing the association between baseline LVH and outcomes after surgical or TAVR for aortic stenosis (AS) have yielded conflicting results.MethodsPatients with severe symptomatic AS at intermediate or high risk in the PARTNER (Placement of Aortic Transcatheter Valve) 1, 2, and S3 trials and registries who received TAVR and had baseline measurements for left ventricular mass index (LVMi) were analyzed. The presence and severity of LVH was determined by LVMi using American Society of Echocardiography sex-specific cutoffs.ResultsAmong 4,280 patients, those with no (n = 1,325), mild (n = 777), moderate (n = 628), and severe (n = 1,550) LVH had 5-year rates of death of 32.8%, 37.3%, 37.2%, and 44.8%, respectively (p < 0.001), and 5-year rates of cardiovascular (CV) death or rehospitalization of 33.6%, 39.2%, 42.4%, and 49.2%, respectively (p < 0.001). After adjustment, severe LVH (compared with no LVH) was associated with increased all-cause death (adjusted hazard ratio: 1.16; 95% confidence interval: 1.00 to 1.34; p = 0.04) and CV death or rehospitalization (adjusted hazard ratio: 1.34; 95% confidence interval: 1.16 to 1.54; p < 0.001), but no increased hazard was observed for mild or moderate LVH. In spline analyses performed in males and females separately, there was a consistent linear association between increased LVMi and an increased adjusted hazard of CV mortality or rehospitalization. A similar relationship was observed for all-cause death in females, but not males.ConclusionsSevere baseline LVH is associated with higher 5-year death and rehospitalization rates after TAVR. These findings may have implications for the optimal timing of valve replacement and the potential role for medical therapy to slow or prevent LVH as AS progresses before valve replacement, but further studies are needed.  相似文献   

6.
ObjectivesThe TRISCEND study (Edwards EVOQUE Tricuspid Valve Replacement: Investigation of Safety and Clinical Efficacy after Replacement of Tricuspid Valve with Transcatheter Device) is evaluating the safety and performance of transfemoral transcatheter tricuspid valve replacement in patients with clinically significant tricuspid regurgitation (TR) and elevated surgical risk.BackgroundTranscatheter valve replacement could lead to a paradigm shift in treating TR and improving patient quality of life.MethodsIn the prospective, single-arm, multicenter TRISCEND study, patients with symptomatic moderate or greater TR, despite medical therapy, underwent percutaneous transcatheter tricuspid valve replacement with the EVOQUE system. A composite rate of major adverse events, echocardiographic parameters, and clinical, functional, and quality-of-life measures were assessed at 30 days.ResultsFifty-six patients (mean age of 79.3 years, 76.8% female, 91.1% TR severe or greater, 91.1% atrial fibrillation, and 87.5% New York Heart Association functional class III or IV) were treated. At 30 days, TR was reduced to mild or less in 98%. The composite major adverse events rate was 26.8% at 30 days caused by 1 cardiovascular death in a patient with a failed procedure, 2 reinterventions after device embolization, 1 major access site or vascular complication, and 15 severe bleeds, of which none were life-threatening or fatal. No myocardial infarction, stroke, renal failure, major cardiac structural complications, or device-related pulmonary embolism were observed. New York Heart Association significantly improved to functional class I or II (78.8%; P < 0.001), 6-minute walk distance improved 49.8 m (P < 0.001), and Kansas City Cardiomyopathy Questionnaire score improved 19 points (P < 0.001).ConclusionsEarly experience with the transfemoral EVOQUE system in patients with clinically significant TR demonstrated technical feasibility, acceptable safety, TR reduction, and symptomatic improvement at 30 days. The TRISCEND II randomized trial (NCT04482062) is underway.  相似文献   

7.
《JACC: Cardiovascular Imaging》2022,15(10):1730-1741
BackgroundGrading of aortic regurgitation (AR) and mitral regurgitation (MR) is similar in the cardiology guidelines despite distinct differences in left ventricular (LV) adaptive pathophysiology.ObjectivesThis study compared differences in LV remodeling in patients with similar degrees of AR and MR severity and evaluated optimal cutoffs for significant AR in relation to the outcome of aortic valve replacement or repair (AVR) during follow-up.MethodsFrom 2008 to 2018, consecutive patients with isolated AR or MR who had cardiac magnetic resonance (CMR) were identified and CMR parameters were compared. Patients with left ventricular ejection fraction (LVEF) <50%, ischemic scar >5%, valve stenosis, or concomitant regurgitation were excluded. Patients were followed longitudinally for AVR.ResultsBaseline characteristics of isolated AR (n = 418) and isolated MR (n = 1,073) were comparable except for higher male proportion and hypertension in AR, while heart failure was more prevalent in MR. Indexed LV end-diastolic and end-systolic volumes and mass were higher in AR compared with MR at the same level of regurgitant fraction. During follow-up (mean 2.1 years), 18.7% of AR patients underwent AVR based on symptoms or LV remodeling. Interestingly, 38.0% of patients that underwent AVR within 3 months after CMR did not meet severe AVR by current guidelines of AR severity. AR regurgitant fraction>35% had high sensitivity (86%) and specificity (88%) for identifying patients who underwent AVR.ConclusionsFor similar regurgitation severity, LV remodeling is different in AR compared with MR. Cardiac symptoms and significant LV remodeling in AR requiring AVR occur frequently in patients with less severity than currently proposed. The study findings suggest that the optimal threshold for severe AR with CMR is different than MR and is lower than currently stated in the guidelines.  相似文献   

8.
ObjectivesThe aim of this study was to prospectively evaluate the clinical use of patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) morphology.BackgroundPatient-specific computer simulation of TAVR in BAV may predict important clinical outcomes, such as paravalvular regurgitation and conduction disturbance.MethodsBetween May 2018 and April 2019, all patients who were referred for TAVR who had BAV identified on work-up cardiac multidetector computed tomographic imaging prospectively underwent patient-specific computer simulation with a self-expanding transcatheter heart valve (THV) using TAVIguide technology.ResultsNine patients were included in the study. Sievers classification was type 0 in 2 patients and type 1 in 7 patients. The simulations altered the treatment strategy in 8 patients (89%). The simulations suggested moderate to severe paravalvular regurgitation in 3 patients, who were referred for consideration of surgery. The remaining 6 patients underwent TAVR with a self-expanding THV. In 5 of these patients (83%), THV size and/or implantation depth was altered to minimize paravalvular regurgitation and/or conduction disturbance. In 1 patient, simulations suggested significant conduction disturbance after TAVR, and a permanent pacemaker was implanted before the procedure. Following treatment, all 9 patients had no to mild paravalvular regurgitation. The patient who had a pre-procedure permanent pacemaker implanted became pacing dependent, with underlying third-degree atrioventricular block.ConclusionsPatient-specific computer simulation of TAVR in BAV can be used to identify those patients where TAVR may be associated with unfavorable clinical outcomes. Patient-specific computer simulation may be useful to guide THV sizing and positioning for potential favorable clinical outcomes.  相似文献   

9.
ObjectivesThe aim of this study was to determine the safety and efficacy of same-day discharge (SDD) after transcatheter aortic valve replacement (TAVR) during the COVID-19 pandemic.BackgroundThe COVID-19 pandemic has placed significant stress on health care systems worldwide. SDD in highly selected TAVR patients can facilitate the provision of essential cardiovascular care while managing competing COVID-19 resource demands.MethodsPatient selection for SDD was at the discretion of the local multidisciplinary heart team, across 7 international sites. The primary outcome was a composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new permanent pacemaker (PPM) implantation.ResultsFrom March 2020 to August 2021, 124 of 2,100 patients who underwent elective transfemoral TAVR were selected for SDD. The average age was 78.9 ± 7.8 years, the median Society of Thoracic Surgeons score was 2.4 (IQR: 1.4-4.2), and 32.3% (n = 40) had preexisting PPMs. There were no major vascular complications, strokes, or deaths during the index admission. One patient (0.8%) required PPM implantation for complete heart block and was discharged the same day. No patient required a PPM between discharge home and 30-day follow-up. The composite of cardiovascular death, stroke, myocardial infarction, all-cause readmission, major vascular complications, and new PPM at 30 days occurred in 5.7% patients (n = 6 of 106).ConclusionsSDD post-TAVR is safe and feasible in selected patients at low risk for adverse clinical events postdischarge. This strategy may have a potential role in highly selected patients even when the COVID-19 pandemic abates.  相似文献   

10.
ObjectivesThe aim of this study was to evaluate device success of transcatheter aortic valve replacement (TAVR) using new-generation balloon-expandable prostheses with or without balloon aortic valvuloplasty (BAV).BackgroundRandomized studies are lacking comparing TAVR without BAV against the conventional technique of TAVR with BAV.MethodsDIRECTAVI (Direct Transcatheter Aortic Valve Implantation) was an open-label noninferiority study that randomized patients undergoing TAVR using the Edwards SAPIEN 3 valve with or without prior balloon valvuloplasty. The primary endpoint was the device success rate according to Valve Academic Research Consortium-2 criteria, which was evaluated using a 7% noninferiority margin. The secondary endpoint included procedural and 30-day adverse events.ResultsDevice success was recorded for 184 of 236 included patients (78.0%). The rate of device success in the direct implantation group (n = 97 [80.2%]) was noninferior to that in the BAV group (n = 87 [75.7%]) (mean difference 4.5%; 95% confidence interval: −4.4% to 13.4%; p = 0.02 for noninferiority). No severe prosthesis-patient mismatch or severe aortic regurgitation occurred in any group. In the direct implantation group, 7 patients (5.8%) required BAV to cross the valve. Adverse events were related mainly to pacemaker implantation (20.9% in the BAV group vs. 19.0% in the direct implantation group; p = 0.70). No significant difference was found between the 2 strategies in duration of procedure, contrast volume, radiation exposure, or rate of post-dilatation.ConclusionsDirect TAVR without prior BAV was noninferior to the conventional strategy using BAV with new-generation balloon-expandable valves, but without procedural simplification. BAV was needed to cross the valve in a few patients, suggesting a need for upstream selection on the basis of patient anatomy. (TAVI Without Balloon Predilatation [of the Aortic Valve] SAPIEN 3 [DIRECTAVI]; NCT02729519)  相似文献   

11.
ObjectivesThis study sought to investigate the impact of computed tomography (CT)–based area and perimeter oversizing on the incidence of paravalvular regurgitation (PVR) and valve hemodynamics in patients treated with the SAPIEN 3 transcatheter heart valve (THV).BackgroundThe incremental value of considering annular perimeter or left ventricular outflow tract measurements and the impact of THV oversizing on valve hemodynamics are not well defined.MethodsThe PARTNER 3 (Placement of Aortic Transcatheter Valves 3) trial included 495 low-surgical-risk patients with severe aortic stenosis who underwent THV implantation. THV sizing was based on annular area assessed by CT. Area- and perimeter-based oversizing was determined using systolic annular CT dimensions and nominal dimensions of the implanted THV. PVR, effective orifice area, and mean gradient were assessed on 30-day transthoracic echocardiography.ResultsOf 485 patients with available CT and echocardiography data, mean oversizing was 7.9 ± 8.7% for the annulus area and 2.1 ± 4.1% for the perimeter. A very low incidence of ≥moderate PVR (0.6%) was observed, including patients with minimal annular oversizing. Incidence of ≥mild PVR and need for procedural post-dilatation were inversely related to the degree of oversizing. For patients with annular dimensions suitable for 2 THV sizes, the larger THV with both area and perimeter oversizing was associated with the lowest incidence of ≥mild PVR (12.0% vs 43.4%; P < 0.0001). Left ventricular outflow tract area oversizing was not associated with PVR. THV prosthesis size, rather than degree of oversizing, had greatest impact on effective orifice area and mean gradient.ConclusionsIn low-surgical-risk patients, a low incidence of ≥moderate PVR was observed, including patients with minimal THV oversizing. The degree of prosthesis oversizing had the greatest impact on reducing mild PVR and incidence of post-dilatation, without impacting valve hemodynamics. In selected patients with annular dimensions in between 2 valve sizes, the larger THV device oversized to both the annular area and perimeter reduced PVR and optimized THV hemodynamics.  相似文献   

12.
ObjectivesThis study sought to compare outcomes in patients with bicuspid versus tricuspid anatomy undergoing transcatheter aortic valve replacement (TAVR).BackgroundTAVR has shown excellent safety and efficacy in patients with tricuspid aortic valve stenosis, but limited data are available on the use of self-expanding valves in patients with bicuspid valves.MethodsThe Society of Thoracic Surgeons/American College of Cardiology TVT Registry was used to analyze patients who underwent TAVR with the Evolut R or Evolut PRO valves. Clinical and echocardiographic outcomes were analyzed through 1-year follow-up.ResultsBetween July 2015 and September 2018 a total of 932 patients with bicuspid aortic valve stenosis underwent elective TAVR with the self-expanding Evolut R or Evolut PRO valve. These patients were compared with a group of 26,154 patients with tricuspid aortic stenosis who underwent TAVR during that same time period. At baseline, patients with bicuspid valves were younger, had fewer cardiac comorbidities, and had lower Society of Thoracic Surgeons Predicted Risk of Mortality scores (5.3 ± 4.2% vs. 6.9 ± 4.8%; p < 0.001). To account for these differences, propensity matching was performed, which resulted in 929 matched pairs. Within these match groups, the rates of all-cause mortality at 30 days (2.6% vs. 1.7%; p = 0.18) and 1 year (10.4% vs. 12.1%; p = 0.63), as well the rate of stroke at 30 days (3.4% vs. 2.7%; p = 0.41) and 1 year (3.9% vs. 4.4%; p = 0.93), were comparable.ConclusionsAll-cause mortality, stroke, and valve hemodynamics did not differ at 30 days or 1 year between patient groups. In patients at increased surgical risk, TAVR for bicuspid aortic valve stenosis indicates acceptable safety outcomes with low complications rates.  相似文献   

13.
BackgroundTranscatheter aortic valve replacement (TAVR)–related coronary artery obstruction prediction remains unsatisfactory despite high mortality and novel preventive therapies.ObjectivesThis study sought to develop a predictive model for TAVR-related coronary obstruction in native aortic stenosis.MethodsPreprocedure computed tomography and fluoroscopy images of patients in whom TAVR caused coronary artery obstruction were collected. Central laboratories made measurements, which were compared with unobstructed patients from a single-center database. A multivariate model was developed and validated against a 1:1 propensity-matched subselection of the unobstructed cohort.ResultsSixty patients with angiographically confirmed coronary obstruction and 1,381 without obstruction were included. In-hospital death was higher in the obstruction cohort (26.7% vs 0.7%; P < 0.001). Annular area and perimeter, coronary height, sinus width, and sinotubular junction height and width were all significantly smaller in the obstructed cohort. Obstruction was most common on the left side (78.3%) and at the level of the coronary artery ostium (92.1%). Coronary artery height and sinus width, but not annulus area, were significant risk factors for obstruction by logistic regression but performed poorly in predicting obstruction. The new multivariate model (coronary obstruction IF cusp height > coronary height, AND virtual valve-to-coronary distance ≤4 mm OR culprit leaflet calcium volume >600 mm3) performed well, with an area under the curve of 0.93 (sensitivity = 0.93, specificity = 0.84) for the left coronary artery and 0.94 (sensitivity = 0.92, specificity = 0.96) for the right.ConclusionsA novel computed tomography–based multivariate prediction model that can be implemented routinely in real-world practice predicted coronary artery obstruction from TAVR in native aortic stenosis.  相似文献   

14.
ObjectivesThe purpose of this study was to examine the impact of residual mitral regurgitation (MR) on mortality in patients undergoing transcatheter aortic valve replacement (TAVR).BackgroundMR is common in patients undergoing TAVR. Data on optimal management of patients with significant MR after TAVR are limited.MethodsThe registry consisted of 16 TAVR centers (n = 7,303). Outcomes of patients with ≥ moderate versus lesser grade MR after TAVR were compared.ResultsIn 1,983 (27.2%) patients, baseline MR grade was ≥ moderate. MR regressed in 874 (44.1%) patients and persisted in 1,109 (55.9%) after TAVR. Four-year mortality was higher for those with MR persistence, but not for those with MR regression after TAVR, compared with nonsignificant baseline MR (43.8% vs. 35.1% vs. 32.4%; hazard ratio [HR]: 1.38; p = 0.008; HR: 1.02; p = 0.383, respectively). New York Heart Association functional class III to IV after TAVR was more common in those with MR persistence vs. regression (14.4% vs. 3.9%; p < 0.001). In a propensity score–matched cohort (91 patients’ pairs), with significant residual MR after TAVR who did or did not undergo staged mitral intervention, staged intervention was associated with a better functional class through 1 year of follow-up (82.4% vs. 33.3% New York Heart Association functional class I or II; p < 0.001), and a numerically lower 4-year mortality, which was not statistically significant (64.6% vs. 37.5%; HR: 1.66; p = 0.097).ConclusionsRisk stratification based on improvement in MR and symptoms after TAVR can identify patients at increased mortality risk after TAVR. These patients may benefit from a staged transcatheter mitral intervention, but this requires further proof from future studies. (Transcatheter Treatment for Combined Aortic and Mitral Valve Disease. The Aortic+Mitral TRAnsCatheter [AMTRAC] Valve Registry [AMTRAC]; NCT04031274).  相似文献   

15.
ObjectivesThe aim of this study was to evaluate clinical characteristics, mechanisms of failure, and outcomes of transcatheter aortic valve replacement (TAVR) explantation.BackgroundSurgical explantation following TAVR may be required for structural valve degeneration, paravalvular leak, infection, or other reasons. However, in-depth data on indications and outcomes are lacking.MethodsData from a multicenter, international registry (EXPLANT-TAVR) of patients who underwent TAVR explantation were reviewed retrospectively. Explantations performed during the same admission as initial TAVR were excluded. Clinical and echocardiographic outcomes were evaluated. Median follow-up duration was 6.7 months (interquartile range [IQR]: 1.0-18.8 months) after TAVR explantation and was 97.7% complete at 30 days and 86.1% complete at 1 year.ResultsFrom November 2009 to September 2020, 269 patients across 42 centers with a mean age of 72.7 ± 10.4 years underwent TAVR explantation. About one quarter (25.9%) were deemed low surgical risk at index TAVR, and median Society of Thoracic Surgeons risk at TAVR explantation was 5.6% (IQR: 3.2%-9.6%). The median time to explantation was 11.5 months (IQR: 4.0-32.4 months). Balloon-expandable and self-expanding or mechanically expandable valves accounted for 50.9% and 49.1%, respectively. Indications for explantation included endocarditis (43.1%), structural valve degeneration (20.1%), paravalvular leak (18.2%), and prosthesis-patient mismatch (10.8%). Redo TAVR was not feasible because of unfavorable anatomy in 26.8% of patients. Urgent or emergency cases were performed in 53.1% of patients, aortic root replacement in 13.4%, and 54.6% had concomitant cardiac procedures. Overall survival at last follow-up was 76.1%. In-hospital, 30-day, and 1-year mortality rates were 11.9%, 13.1%, and 28.5%, respectively, and stroke rates were 5.9%, 8.6%, and 18.7%, respectively.ConclusionsThe EXPLANT-TAVR registry reveals that surgical risks associated with TAVR explantation are not negligible and should be taken into consideration in the lifetime management of aortic stenosis.  相似文献   

16.
ObjectivesThe aim of this study was to assess the evolution of early outcomes for 3 iterative self-expanding transcatheter aortic valves.BackgroundOver the past decade there have been rapid advancements in transcatheter aortic valve replacement (TAVR) technologies, including 3 generations of supra-annular self-expanding transcatheter systems.MethodsData from the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry for patients undergoing TAVR with CoreValve, Evolut R, or Evolut PRO valves to treat tricuspid aortic stenosis between January 2014 and September 2017 were obtained. Patient risk and echocardiographic data are site reported. Valves analyzed included 23-, 26-, and 29-mm sizes to fit 18- to 26-mm annular diameters. Propensity score matching was performed using the Evolut PRO group as the common reference.ResultsOf 18,874 patients undergoing TAVR at 381 centers, 5,514 patients were implanted with CoreValve, 11,295 with Evolut R, and 2,065 with Evolut PRO valves. At 30 days, there were significantly fewer patients with more than mild aortic regurgitation for the unmatched (7.8% CoreValve, 5.2% Evolut R, and 2.8% Evolut PRO; p < 0.001) and matched populations (8.3% CoreValve, 5.4% Evolut R, and 3.4% Evolut PRO; p = 0.032). The mean aortic valve gradients at 30 days in the matched populations were <8 mm Hg for all 3 valves (7.3 mm Hg CoreValve, 7.5 mm Hg Evolut R, 7.2 mm Hg Evolut PRO).ConclusionsAdvancements in transcatheter valve technologies and expanding indications for TAVR have resulted in improved outcomes for patients undergoing TAVR in the United States with self-expanding, supra-annular valves. In particular, the addition of an outer pericardial tissue wrap designed to enhance sealing at the level of the aortic annulus has resulted in very low rates of significant aortic regurgitation while maintaining excellent hemodynamic status.  相似文献   

17.
ObjectivesThis study sought to evaluate the 30-day and 1-year safety and performance of the Hydra transcatheter aortic valve (THV) in the treatment of symptomatic severe aortic stenosis in patients at high or extreme surgical risk.BackgroundThe Hydra THV is a novel repositionable self-expanding system with supra-annular bovine pericardial leaflets.MethodsThe Hydra CE study was a premarket, prospective, multicenter, single-arm study conducted across 18 study centers in Europe and Asia-Pacific countries. The primary endpoint was all-cause mortality at 30 days. All endpoints were adjudicated by an independent clinical events committee.ResultsA total of 157 patients (79.2 ± 7.1 years of age, 58.6% female; Society of Thoracic Surgeons score 4.7 ± 3.4%) were enrolled. Successful implantation was achieved in 94.3% cases. At 30 days, there were 11 (7.0%) deaths, including 9 (5.7%) cardiovascular deaths, of which 5 (3.2%) were device related. At 1 year, there were 23 (14.6%) deaths, including 13 (8.3%) cardiovascular deaths. At 30 days, there were significant improvement of effective orifice area (from 0.7 ± 0.2 cm2 to 1.9 ± 0.6 cm2) and mean aortic valve gradient (from 49.5 ± 18.5 mm Hg to 8.1 ± 3.7 mm Hg), which were sustained up to 1 year. Moderate or severe paravalvular leak was observed in 6.3% of patients at 30 days and 6.9% of patients at 1 year. The rate of new permanent pacemaker implantation was 11.7% at 30 days and 12.4% at 1 year.ConclusionsThe Hydra CE study demonstrated that transcatheter aortic valve replacement with Hydra THV offered favorable efficacy at 1 year, providing large effective orifice area and low transvalvular gradient as well as acceptable complication rates with regard to new permanent pacemaker and paravalvular leak. (A Clinical Evaluation of the HYDRA Self Expanding Transcatheter Aortic Valve; NCT02434263)  相似文献   

18.
ObjectivesThe aim of this study was to assess the added value and predictive power of the TAVIguide (Added Value of Patient-Specific Computer Simulation in Transcatheter Aortic Valve Implantation) software in clinical practice.BackgroundOptimal outcome after transcatheter aortic valve replacement (TAVR) may become more important as TAVR shifts toward low-risk patients. Patient-specific computer simulation is able to provide prediction of outcome after TAVR. Its clinical role and validation of accuracy, however, have not yet been studied prospectively.MethodsA prospective, observational, multicenter study was conducted among 80 patients with severe aortic stenosis treated with the Evolut R valve. Simulation was performed in 42 patients and no simulation in 38. A comparison between the valve size (decision 1) and target depth of implantation selected by the operator on the basis of multislice computed tomography and the valve size (decision 2) and target depth of implantation selected after simulation were the primary endpoints. Predictive power was examined by comparing the simulated and observed degree of aortic regurgitation.ResultsDecision 2 differed from decision 1 in 1 of 42 patients because of predicted paravalvular leakage, and changes in valve type occurred in 2 of 42. In 39 of 42 patients, decisions 1 and 2 were similar. Target depth of implantation differed in 7 of 42 patients after simulation (lower in 4 and higher in 3). In 16 of 42 patients, simulation affected the TAVR procedure; in 9, the operator avoided additional measures to achieve the target depth of implantation, and in 7 patients, additional measures were performed. There was a trend toward a higher degree of predicted than observed aortic regurgitation (17.5 vs. 12 ml/s; p = 0.13).ConclusionsPatient-specific computer simulation did not affect valve size selection but did affect the selection of the target depth of implantation and the execution of TAVR to achieve the desired target depth of implantation.  相似文献   

19.
BackgroundSignificant tricuspid regurgitation (TR) is associated with poor outcome and high operative mortality resulting from late presentation. Yet, the optimal timing for intervention is unknown.ObjectivesThe purpose of this study was to evaluate the prognostic value of echocardiographic parameters to inform early intervention in asymptomatic TR.MethodsUsing the Cleveland Clinic echocardiography database 2004 to 2018, the authors identified a consecutive cohort of asymptomatic patients with moderate to severe (3+) or severe (4+) TR. Quantitative TR and right heart parameters were retrospectively determined, and their prognostic utility for all-cause mortality was assessed.ResultsIn 325 asymptomatic patients (mean age: 67.9 years; 79.4% female) with at least 3+ TR, there were 132 deaths (40.6%), with a median survival time of 9.9 years (95% CI: 7.9-12.7 years). By contrast, the median survival time in an age- and sex-matched cohort of symptomatic TR patients was 4.4 years (95% CI: 2.8-5.9 years). Among all the echocardiographic parameters evaluated, right ventricle free wall strain (RVFWS) and tricuspid regurgitant volume (RVol) were the strongest predictors of mortality in asymptomatic TR. The optimal discriminatory thresholds for these parameters were RVFWS <?19% and RVol >45 mL. The 5-year survival rates by number of risk factors (RF) were 93% (95% CI: 86%-96%), 65% (95% CI: 55%-74%), and 38% (95% CI: 26%-49%) for no RF, 1 RF, and both RFs, respectively. Compared with symptomatic TR, mortality was lower for asymptomatic TR with no RF (HR: 0.10; 95% CI: 0.04-0.29) or 1 RF (HR: 0.29; 95% CI: 0.14-0.58), but similar for asymptomatic TR with both RFs (HR: 1.11; 95% CI: 0.56-2.19).ConclusionsRVFWS and RVol are key prognostic markers that can be serially monitored to inform optimal timing of intervention for severe asymptomatic TR.  相似文献   

20.
ObjectivesThe purpose of this study was to evaluate clinical and echocardiographic outcome data of the CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients with Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT) trial at 5 years.BackgroundThe CHOICE trial was designed to compare device performance of a balloon-expandable (BE) transcatheter heart valve (THV) versus a self-expanding (SE) THV.MethodsThe CHOICE trial is an investigator-initiated trial that randomized 241 high-risk patients with severe symptomatic aortic stenosis and an anatomy suitable for treatment with both BE and SE THVs to transfemoral transcatheter aortic valve replacement with either device. The primary endpoint was device success. Patients were followed up to 5 years, with assessment of clinical outcomes, and echocardiographic evaluation of valve function and THV durability.ResultsAfter 5 years, there were no statistically significant differences between BE and SE valves in the cumulative incidence of death from any cause (53.4% vs. 47.6%; p = 0.38), death from cardiovascular causes (31.6% vs. 21.5%; p = 0.12), all strokes (17.5% vs. 16.5%; p = 0.73), and repeat hospitalization for heart failure (28.9% vs. 22.5%; p = 0.75). SE patients had larger prosthetic valve area (1.6 ± 0.5 cm2 vs. 1.9 ± 0.5 cm2; p = 0.02) with a lower mean transprosthetic gradient (12.2 ± 8.7 mm Hg vs. 6.9 ± 2.7 mm Hg; p = 0.001) at 5 years. No differences were observed in the rates of paravalvular regurgitation. Clinical valve thrombosis occurred in 7 BE patients (7.3%) and 1 SE patient (0.8%; p = 0.06), and moderate or severe structural valve deterioration in 6 BE patients (6.6%) and no SE patient (0%; p = 0.018). The rate of bioprosthetic valve failure was low and not significantly different between both groups (4.1% vs. 3.4%; p = 0.63).ConclusionsFive-year follow-up of patients in the CHOICE trial revealed clinical outcomes after transfemoral transcatheter aortic valve replacement with early-generation BE and SE valves that were not statistically significantly different, with limited statistical power. Forward flow hemodynamics were significantly better with the SE valve. Moderate or severe structural valve deterioration was uncommon but occurred more frequently with the BE valve. (A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial [CHOICE]; NCT01645202)  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号