首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BackgroundAmong patients with acute coronary syndrome following transcatheter aortic valve replacement (TAVR), those presenting with ST-segment elevation myocardial infarction (STEMI) are at highest risk.ObjectivesThe goal of this study was to determine the clinical characteristics, management, and outcomes of STEMI after TAVR.MethodsThis was a multicenter study including 118 patients presenting with STEMI at a median of 255 days (interquartile range: 9 to 680 days) after TAVR. Procedural features of STEMI after TAVR managed with primary percutaneous coronary intervention (PCI) were compared with all-comer STEMI: 439 non-TAVR patients who had primary PCI within the 2 weeks before and after each post-TAVR STEMI case in 5 participating centers from different countries.ResultsMedian door-to-balloon time was higher in TAVR patients (40 min [interquartile range: 25 to 57 min] vs. 30 min [interquartile range: 25 to 35 min]; p = 0.003). Procedural time, fluoroscopy time, dose-area product, and contrast volume were also higher in TAVR patients (p < 0.01 for all). PCI failure occurred more frequently in patients with previous TAVR (16.5% vs. 3.9%; p < 0.001), including 5 patients in whom the culprit lesion was not revascularized owing to coronary ostia cannulation failure. In-hospital and late (median of 7 months [interquartile range: 1 to 21 months]) mortality rates were 25.4% and 42.4%, respectively (20.6% and 38.2% in primary PCI patients), and estimated glomerular filtration rate <60 ml/min (hazard ratio [HR]: 3.02; 95% confidence interval [CI]: 1.42 to 6.43; p = 0.004), Killip class ≥2 (HR: 2.74; 95% CI: 1.37 to 5.49; p = 0.004), and PCI failure (HR: 3.23; 95% CI: 1.42 to 7.31; p = 0.005) determined an increased risk.ConclusionsSTEMI after TAVR was associated with very high in-hospital and mid-term mortality. Longer door-to-balloon times and a higher PCI failure rate were observed in TAVR patients, partially due to coronary access issues specific to the TAVR population, and this was associated with poorer outcomes.  相似文献   

2.
BackgroundAortic stenosis and coronary artery disease (CAD) frequently coincide. However, the management of coexisting CAD in patients undergoing transcatheter aortic valve replacement (TAVR) remains controversial.ObjectivesThis study sought to determine whether the presence of CAD, its complexity, and angiography-guided percutaneous coronary intervention (PCI) are associated with outcomes after TAVR.MethodsAll patients undergoing TAVR at a tertiary referral center between 2008 and 2020 were included in a prospective observational study. Baseline SYNTAX (Synergy between PCI with Taxus and Cardiac Surgery) score (SS) and, whenever applicable, a residual SS after PCI were calculated. A multivariate analysis was performed to determine the effect of CAD, stratified according to complexity, and PCI on 5-year outcomes.ResultsIn 604 patients, the presence of CAD and its complexity were significantly associated with worse 5-year survival (SS 0: 67.9% vs SS 1-22: 56.1% vs SS >22: 53.0%; log-rank P = 0.027) and increased cardiovascular mortality (SS 0: 15.1% vs SS 1-22: 24.0% vs SS >22: 27.8%; log-rank P = 0.024) after TAVR. Having noncomplex CAD (SS 1-22) was an independent predictor for increased all-cause mortality (HR: 1.43; P = 0.046), while complex CAD (SS >22) increased cardiovascular mortality significantly (HR: 1.84; P = 0.041). Angiography-guided PCI or completeness of revascularization was not associated with different outcomes.ConclusionsThe presence of CAD and its anatomical complexity in patients undergoing TAVR are associated with significantly worse 5-year outcomes. However, angiography-guided PCI did not improve outcomes, highlighting the need for further research into physiology-guided PCI.  相似文献   

3.
ObjectivesThe aim of this study was to evaluate the feasibility of coronary access and aortic valve reintervention in low-risk patients undergoing transcatheter aortic valve replacement (TAVR) with a balloon-expandable transcatheter heart valve (THV).BackgroundYounger, low-risk TAVR patients are more likely than older, higher risk patients to require coronary angiography, percutaneous coronary intervention, or aortic valve reintervention, but their THVs may impede coronary access and cause coronary obstruction during TAVR-in-TAVR.MethodsThe LRT (Low Risk TAVR) trial (NCT02628899) enrolled 200 subjects with symptomatic severe aortic stenosis to undergo TAVR using commercially available THVs. Subjects who received balloon-expandable THVs and who had 30-day cardiac computed tomographic scans were included in this study. In a subgroup, the feasibility of intentional THV crimping on the delivery catheter to pre-determine commissural alignment was tested.ResultsIn the LRT trial, 168 subjects received balloon-expandable THVs and had 30-day cardiac computed tomographic scans, of which 137 were of adequate image quality for analysis. The most challenging anatomy for coronary access (THV frame above and commissural suture post in front of a coronary ostium) was observed in 9% to 13% of subjects. Intentional THV crimping did not appear to meaningfully affect commissural alignment. The THV frame extended above the sinotubular junction in 21% of subjects, and in 13%, the distance between the THV and the sinotubular junction was <2 mm, signifying that TAVR-in-TAVR may not be feasible without causing coronary obstruction.ConclusionsTAVR may present challenges to future coronary access and aortic valve reintervention in a substantial number of low-risk patients.  相似文献   

4.
ObjectivesThe aim of this study was to compare, in a cohort of patients with complex coronary artery disease (CAD) and severe aortic stenosis (AS), the clinical outcomes associated with transfemoral transcatheter aortic valve replacement (TAVR) (plus percutaneous coronary intervention [PCI]) versus surgical aortic valve replacement (SAVR) (plus coronary artery bypass grafting [CABG]).BackgroundPatients with complex CAD were excluded from the main randomized trials comparing TAVR with SAVR, and no data exist comparing TAVR + PCI vs SAVR + CABG in such patients.MethodsA multicenter study was conducted including consecutive patients with severe AS and complex CAD (SYNTAX [Synergy Between PCI with Taxus and Cardiac Surgery] score >22 or unprotected left main disease). A 1:1 propensity-matched analysis was performed to account for unbalanced covariates. The rates of major adverse cardiac and cerebrovascular events (MACCE), including all-cause mortality, nonprocedural myocardial infarction, need for new coronary revascularization, and stroke, were evaluated.ResultsA total of 800 patients (598 undergoing SAVR + CABG and 202 undergoing transfemoral TAVR + PCI) were included, and after propensity matching, a total of 156 pairs of patients were generated. After a median follow-up period of 3 years (interquartile range: 1-6 years), there were no significant differences between groups for MACCE (HR for transfemoral TAVR vs SAVR: 1.33; 95% CI: 0.89-1.98), all-cause mortality (HR: 1.25; 95% CI: 0.81-1.94), myocardial infarction (HR: 1.16; 95% CI: 0.41-3.27), and stroke (HR: 0.42; 95% CI: 0.13-1.32), but there was a higher rate of new coronary revascularization in the TAVR + PCI group (HR: 5.38; 95% CI: 1.73-16.7).ConclusionsIn patients with severe AS and complex CAD, TAVR + PCI and SAVR + CABG were associated with similar rates of MACCE after a median follow-up period of 3 years, but TAVR + PCI recipients exhibited a higher risk for repeat coronary revascularization. Future trials are warranted.  相似文献   

5.
ObjectivesA large comprehensive analysis of transcatheter aortic valve replacement (TAVR) was performed for failed stentless bioprostheses.BackgroundValve-in-valve (ViV) transcatheter aortic replacement (TAVR) is an alternative to redo surgery for patients with a failing aortic bioprosthesis.MethodsUnadjusted outcome data were collected from the VIVID (Valve-in-Valve International Data) registry between 2007 and 2016 from a total of 1,598 aortic ViV procedures (291 stentless, 1,307 stented bioprostheses).ResultsBioprosthetic failure was secondary to aortic regurgitation in 56% of stentless and 20% stented devices (p < 0.001). ViV-TAVR access was transfemoral in 71.1% stentless and 74.2% stented ViV-TAVR. Self-expanding devices were more frequently used in stentless ViV-TAVR (56.0% vs. 39.9%; p = 0.05), but there was no difference between balloon-expanding and self-expanding TAVR devices for stented ViV-TAVR (48.6% vs. 45.1%). The degree of oversizing for all mechanisms of bioprosthesis failure was 9 ± 10% for stentless ViV-TAVR vs. 6 ± 9% for stented ViV-TAVR (and 8 ± 10% for stentless ViV-TAVR vs. 3 ± 9% for stented ViV-TAVR in patients with predominant aortic regurgitation; both p < 0.001). Initial device malposition (10.3% vs. 6.2%; p = 0.014), second transcatheter device (7.9% vs. 3.4%), coronary obstruction (6.0% vs. 1.5%), and paravalvular leak occurred more frequently in stentless ViV-TAVR (all p < 0.001). Hospital stay duration (median 7 days) was no different, and 30-day (6.6% vs. 4.4%; p = 0.12) and 1-year mortality year (15.8% vs. 12.6%; p = 0.15) were numerically higher, but not statistically different, after stentless ViV-TAVR.ConclusionsStentless ViV-TAVR is associated with greater periprocedural complications (initial device malposition, second transcatheter device, coronary obstruction, paravalvular leak), but no difference in 30-day and 1-year outcome.  相似文献   

6.
ObjectivesThe aim of this study was to characterize the feasibility of coronary angiography (CA) and percutaneous coronary intervention (PCI) in acute settings among patients who have undergone transcatheter aortic valve replacement (TAVR).BackgroundImpaired coronary access after TAVR may be challenging and particularly in acute settings could have deleterious consequences.MethodsIn this international registry, data from patients with prior TAVR requiring urgent or emergent CA were retrospectively collected. A total of 449 patients from 25 sites with acute coronary syndromes (89.1%) and other acute cardiovascular situations (10.9%) were included.ResultsSuccess rates were high for CA of the right coronary artery (98.3%) and left coronary artery (99.3%) and were higher among patients with short stent-frame prostheses (SFPs) than in those with long SFPs for CA of the right coronary artery (99.6% vs 95.9%; P = 0.005) but not for CA of the left coronary artery (99.7% vs 98.7%; P = 0.24). PCI of native coronary arteries was successful in 91.4% of cases and independent of valve type (short SFP 90.4% vs long SFP 93.4%; P = 0.44). Guide engagement failed in 6 patients, of whom 3 underwent emergent coronary artery bypass grafting and another 3 died in the hospital. Among patients requiring revascularization of native vessels, independent predictors of 30-day all-cause mortality were prior diabetes, cardiogenic shock, and failed PCI but not valve type or success of coronary engagement.ConclusionsCA or PCI after TAVR in acute settings is usually successful, but selective coronary engagement may be more challenging in the presence of long SFPs. Among patients requiring PCI, prior diabetes, cardiogenic shock, and failed PCI were predictors of early mortality.  相似文献   

7.
ObjectivesThis study sought to address a knowledge gap by examining the incidence, timing, and predictors of acute coronary syndrome (ACS) after transcatheter aortic valve replacement (TAVR) in Medicare beneficiaries.BackgroundEvidence about incidence and outcomes of ACS after TAVR is scarce.MethodsWe identified Medicare patients who underwent TAVR from 2012 to 2017 and were admitted with ACS during follow-up. We compared outcomes based on the type of ACS: ST-segment elevation myocardial infarction (STEMI), non-STEMI (NSTEMI), and unstable angina. In patients with non–ST-segment elevation ACS, we compared outcomes based on the treatment strategy (invasive vs. conservative) using inverse probability weighting analysis.ResultsOut of 142,845 patients with TAVR, 6,741 patients (4.7%) were admitted with ACS after a median time of 297 days (interquartile range: 85 to 662 days), with 48% of admissions occurring within 6 months. The most common presentation was NSTEMI. Predictors of ACS were history of coronary artery disease, prior revascularization, diabetes, valve-in-TAVR, and acute kidney injury. STEMI was associated with higher 30-day and 1-year mortality compared with NSTEMI (31.4% vs. 15.5% and 51.2% vs. 41.3%, respectively; p < 0.01). Overall, 30.3% of patients with non–ST-segment elevation ACS were treated with invasive approach. On inverse probability weighting analysis, invasive approach was associated with lower adjusted long-term mortality (adjusted hazard ratio: 0.69; 95% confidence interval: 0.66 to 0.73; p < 0.01) and higher risk of repeat revascularization (adjusted hazard ratio: 1.29; 95% confidence interval: 1.16 to 1.43; p < 0.001).ConclusionsAfter TAVR, ACS is infrequent (<5%), and the most common presentation is NSTEMI. Occurrence of STEMI after TAVR is associated with a high mortality with nearly one-third of patients dying within 30 days. Optimization of care is needed for post-TAVR ACS patients and if feasible, invasive approach should be considered in these high-risk patients.  相似文献   

8.
ObjectivesThis study sought to determine if percutaneous coronary intervention (PCI) prior to transcatheter aortic valve replacement (TAVR) in patients with significant coronary artery disease would produce noninferior clinical results when compared with no PCI (control arm).BackgroundPCI in patients undergoing TAVR is not without risk, and there are no randomized data to inform clinical practice.MethodsPatients with severe symptomatic aortic stenosis and significant coronary artery disease with Canadian Cardiovascular Society class ≤2 angina were randomly assigned to receive PCI or no PCI prior to TAVR. The primary endpoint was a composite of all-cause death or rehospitalization at 1 year. Noninferiority testing (prespecified margin of 7.5%) was performed in the intention-to-treat population.ResultsAt 17 centers, 235 patients underwent randomization. At 1 year, the primary composite endpoint occurred in 48 (41.5%) of the PCI arm and 47 (44.0%) of the no-PCI arm. The requirement for noninferiority was not met (difference: -2.5%; 1-sided upper 95% confidence limit: 8.5%; 1-sided noninferiority test P = 0.067). On analysis of the as-treated population, the difference was -3.7% (1-sided upper 95% confidence limit: 7.5%; P = 0.050). Mortality was 16 (13.4%) in the PCI arm and 14 (12.1%) in the no-PCI arm. At 1 year, there was no evidence of a difference in the rates of stroke, myocardial infarction, or acute kidney injury, with higher rates of any bleed in the PCI arm (P = 0.021).ConclusionsObserved rates of death and rehospitalization at 1 year were similar between PCI and no PCI prior to TAVR; however, the noninferiority margin was not met, and PCI resulted in a higher incidence of bleeding. (Assessing the Effects of Stenting in Significant Coronary Artery Disease Prior to Transcatheter Aortic Valve Implantation; ISRCTN75836930)  相似文献   

9.
ObjectivesThe purpose of this study was to assess the extent to which the association between premature dual antiplatelet therapy (DAPT) discontinuation and excess risk of thrombotic events varies according to the reason and timing of DAPT discontinuation and whether high on-treatment platelet reactivity (HPR) influences the risk of thrombotic events after premature DAPT discontinuation.BackgroundDAPT after percutaneous coronary intervention (PCI) suppresses platelet reactivity, and HPR on clopidogrel after PCI is associated with an increased risk of thrombotic events.MethodsADAPT-DES (Assessment of Dual Antiplatelet Therapy With Drug-Eluting Stents) was a prospective, multicenter registry of 8,582 patients successfully treated with coronary drug-eluting stents that assessed HPR on clopidogrel. For patients who discontinued aspirin or clopidogrel at any time during the study, the reasons for discontinuation were systematically categorized.ResultsPlanned DAPT discontinuation occurred within 2 years in 3,203 (37.3%) patients. One thousand four hundred eighteen (16.5%) patients discontinued DAPT for unplanned reasons, including surgery or trauma (n = 768 [8.9%]), patient nonadherence (n = 321 [3.7%]), bleeding complications (n = 264 [3.1%]), and drug allergy or hypersensitivity (n = 113 [1.3%]). Unplanned but not planned DAPT discontinuation was associated with an increased risk of a major adverse cardiac event (MACE, defined as the composite of cardiac death, myocardial infarction, or stent thrombosis); with highest risk within 3 months after PCI (adjusted HR: 7.65, 95% CI: 2.77-21.10 vs adjusted HR: 2.47, 95% CI: 1.70-3.58 for unplanned DAPT discontinuation ≥3 months after PCI). MACE risk after DAPT discontinuation was not moderated by HPR (Pinteraction = 0.91).ConclusionsIn this large-scale all-comers registry, premature DAPT discontinuation for unplanned reasons occurred in approximately 1 of 6 patients after DES implantation and was associated with a markedly increased risk of MACEs. (Assessment of Dual AntiPlatelet Therapy With Drug Eluting Stents [ADAPT-DES]; NCT00638794)  相似文献   

10.
ObjectivesThe aim of this study was to assess the incidence of unfavorable coronary access after transcatheter aortic valve replacement (TAVR) using post-implantation computed tomography (CT).BackgroundReal-world data regarding coronary access after TAVR assessed using post-implantation CT are scarce.MethodsPost-TAVR CT of 66 patients treated with Evolut R or Evolut PRO valves and 345 patients treated with SAPIEN 3 valves were analyzed. The distance from inflow of the transcatheter heart valve (THV) to the coronary ostia and the overlap between THV commissures and the coronary ostia were assessed. Coronary access was defined as unfavorable if the coronary ostium was below the skirt or in front of the THV commissural posts above the skirt in each coronary artery.ResultsCT-identified features of unfavorable coronary access were observed in 34.8% (n = 23) for the left coronary artery and 25.8% (n = 17) for the right coronary artery in the Evolut R/Evolut PRO group, while those percentages were 15.7% (n = 54) for the left coronary artery and 8.1% (n = 28) for the right coronary artery in the SAPIEN 3 group. In the Evolut R/Evolut PRO group, 16 coronary engagements were performed after TAVR, while 64 coronary engagements were performed in the SAPIEN 3 group after TAVR. In an engagement-level analysis, the success rates of selective coronary engagement were significantly lower in patients with CT-identified features of unfavorable coronary access compared with those with favorable coronary access in both the Evolut R/Evolut PRO (0.0% vs. 77.8%; p = 0.003) and SAPIEN 3 (33.3% vs. 91.4%; p = 0.003) groups.ConclusionsCoronary access may be challenging in a significant proportion of patients after TAVR. THVs with low skirt or commissure height and large open cells that are designed to achieve commissure-to-commissure alignment with the native aortic valve may facilitate future coronary access. (Assessment of Transcatheter and Surgical Aortic Bioprosthetic Valve Thrombosis and Its Treatment With Anticoagulation [RESOLVE]; NCT02318342)  相似文献   

11.
ObjectivesThe aim of this study was to investigate the safety and efficacy of coronary protection by preventive coronary wiring and stenting across the coronary ostia in patients at high risk for coronary obstruction after transcatheter aortic valve replacement (TAVR).BackgroundCoronary obstruction following TAVR is a life-threatening complication with high procedural and short-term mortality.MethodsData were collected retrospectively from a multicenter international registry between April 2011 and February 2019.ResultsAmong 236 patients undergoing coronary protection with preventive coronary wiring, 143 had eventually stents implanted across the coronary ostia after valve deployment. At 3-year follow-up, rates of cardiac death were 7.8% in patients receiving stents and 15.7% in those not receiving stents (adjusted hazard ratio: 0.42; 95% confidence interval: 0.14 to 1.28; p = 0.13). There were 2 definite stent thromboses (0.9%) in patients receiving stents, both occurring after TAVR in “valve-in-valve” procedures. In patients not receiving stents, there were 4 delayed coronary occlusions (DCOs) (4.3%), occurring from 5 min to 6 h after wire removal. Three cases occurred in valve-in-valve procedures and 1 in a native aortic valve procedure. Distance between the virtual transcatheter valve and the protected coronary ostia <4 mm was present in 75.0% of patients with DCO compared with 30.4% of patients without DCO (p = 0.19).ConclusionsIn patients undergoing TAVR at high risk for coronary obstruction, preventive stent implantation across the coronary ostia is associated with good mid-term survival rates and low rates of stent thrombosis. Patients undergoing coronary protection with wire only have a considerable risk for DCO.  相似文献   

12.
ObjectivesThe aim of this study was to evaluate device success of transcatheter aortic valve replacement (TAVR) using new-generation balloon-expandable prostheses with or without balloon aortic valvuloplasty (BAV).BackgroundRandomized studies are lacking comparing TAVR without BAV against the conventional technique of TAVR with BAV.MethodsDIRECTAVI (Direct Transcatheter Aortic Valve Implantation) was an open-label noninferiority study that randomized patients undergoing TAVR using the Edwards SAPIEN 3 valve with or without prior balloon valvuloplasty. The primary endpoint was the device success rate according to Valve Academic Research Consortium-2 criteria, which was evaluated using a 7% noninferiority margin. The secondary endpoint included procedural and 30-day adverse events.ResultsDevice success was recorded for 184 of 236 included patients (78.0%). The rate of device success in the direct implantation group (n = 97 [80.2%]) was noninferior to that in the BAV group (n = 87 [75.7%]) (mean difference 4.5%; 95% confidence interval: −4.4% to 13.4%; p = 0.02 for noninferiority). No severe prosthesis-patient mismatch or severe aortic regurgitation occurred in any group. In the direct implantation group, 7 patients (5.8%) required BAV to cross the valve. Adverse events were related mainly to pacemaker implantation (20.9% in the BAV group vs. 19.0% in the direct implantation group; p = 0.70). No significant difference was found between the 2 strategies in duration of procedure, contrast volume, radiation exposure, or rate of post-dilatation.ConclusionsDirect TAVR without prior BAV was noninferior to the conventional strategy using BAV with new-generation balloon-expandable valves, but without procedural simplification. BAV was needed to cross the valve in a few patients, suggesting a need for upstream selection on the basis of patient anatomy. (TAVI Without Balloon Predilatation [of the Aortic Valve] SAPIEN 3 [DIRECTAVI]; NCT02729519)  相似文献   

13.
ObjectivesThe aims of this study were to investigate the feasibility of coronary ostia cannulation after transcatheter aortic valve replacement (TAVR) and to assess potential predictors of coronary access impairment.BackgroundCertain data concerning the feasibility and reproducibility of coronary cannulation after TAVR are lacking.MethodsRE-ACCESS (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent) was an investigator-driven, single-center, prospective, registry-based study that enrolled consecutive patients undergoing TAVR using all commercially available devices. All patients underwent coronary angiography before and after TAVR. The primary endpoint was the rate of unsuccessful coronary ostia cannulation after TAVR. Secondary endpoints were the identification of factors associated with the inability to selectively cannulate coronary ostia after TAVR.ResultsAmong 300 patients enrolled in the RE-ACCESS study from December 2018 to January 2020, a total of 23 cases (7.7%) of unsuccessful coronary cannulation after TAVR were documented. This issue occurred in 22 of 23 cases with the use of Evolut R/PRO transcatheter aortic valves (TAVs) (17.9% vs. 0.4%; p < 0.01). In multivariate analysis, the use of Evolut R/PRO TAVs (odds ratio [OR]: 29.6; 95% confidence interval [CI]: 2.6 to 335.0; p < 0.01), the TAV–sinus of Valsalva relation (OR: 1.1 per 1-mm increase; 95% CI: 1.0 to 1.2; p < 0.01), and the mean TAV implantation depth (OR: 1.7 per 1-mm decrease; 95% CI: 1.3 to 2.3; p < 0.01) were found to be independent predictors of unsuccessful coronary cannulation after TAVR. A model combining these factors was demonstrated to predict with very high accuracy the risk for unsuccessful coronary cannulation after TAVR (area under the curve: 0.94; p < 0.01).ConclusionsUnsuccessful coronary cannulation following TAVR was observed in 7.7% of patients and occurred almost exclusively in those receiving Evolut TAVs. The combination of Evolut TAV, a higher TAV–sinus of Valsalva relation, and implantation depth predicts with high accuracy the risk for unsuccessful coronary cannulation after TAVR. (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent [RE-ACCESS]; NCT04026204)  相似文献   

14.
BackgroundSubclinical leaflet thrombosis has been reported after bioprosthetic aortic valve replacement, characterized using 4-dimensional computed tomographic imaging by hypoattenuated leaflet thickening (HALT) and reduced leaflet motion (RLM). The incidence and clinical implications of these findings remain unclear.ObjectivesThe aim of this study was to determine the frequency, predictors, and hemodynamic and clinical correlates of HALT and RLM after aortic bioprosthetic replacement.MethodsA prospective subset of patients not on oral anticoagulation enrolled in the Evolut Low Risk randomized trial underwent computed tomographic imaging 30 days and 1 year after transcatheter aortic valve replacement (TAVR) or surgery. The primary endpoint was the frequency of HALT at 30 days and 1 year, analyzed by an independent core laboratory using standardized definitions. Secondary endpoints included RLM, mean aortic gradient, and clinical events at 30 days and 1 year.ResultsAt 30 days, the frequency of HALT was 31 of 179 (17.3%) for TAVR and 23 of 139 (16.5%) for surgery; the frequency of RLM was 23 of 157 (14.6%) for TAVR and 19 of 133 (14.3%) for surgery. At 1 year, the frequency of HALT was 47 of 152 (30.9%) for TAVR and 33 of 116 (28.4%) for surgery; the frequency of RLM was 45 of 145 (31.0%) for TAVR and 30 of 111 (27.0%) for surgery. Aortic valve hemodynamic status was not influenced by the presence or severity of HALT or RLM at either time point. The rates of HALT and RLM were similar after the implantation of supra-annular, self-expanding transcatheter, or surgical bioprostheses.ConclusionsThe presence of computed tomographic imaging abnormalities of aortic bioprostheses were frequent but dynamic in the first year after self-expanding transcatheter and surgical aortic valve replacement, but these findings did not correlate with aortic valve hemodynamic status after aortic valve replacement in patients at low risk for surgery. (Medtronic Evolut Transcatheter Aortic Valve Replacement in Low Risk Patients; NCT02701283)  相似文献   

15.
BackgroundStroke is one of the most common and potentially disabling complications of infective endocarditis (IE). However, scarce data exist about stroke complicating IE after transcatheter aortic valve replacement (TAVR).ObjectivesThe purpose of this study was to determine the incidence, risk factors, clinical characteristics, management, and outcomes of patients with definite IE after TAVR complicated by stroke during index IE hospitalization.MethodsData from the Infectious Endocarditis after TAVR International Registry (including 569 patients who developed definite IE following TAVR from 59 centers in 11 countries) was analyzed. Patients were divided into two groups according to stroke occurrence during IE admission (stroke [S-IE] vs. no stroke [NS-IE]).ResultsA total of 57 (10%) patients had a stroke during IE hospitalization, with no differences in causative microorganism between groups. S-IE patients exhibited higher rates of acute renal failure, systemic embolization, and persistent bacteremia (p < 0.05 for all). Previous stroke before IE, residual aortic regurgitation ≥moderate after TAVR, balloon-expandable valves, IE within 30 days after TAVR, and vegetation size >8 mm were associated with a higher risk of stroke during the index IE hospitalization (p < 0.05 for all). Stroke rate in patients with no risk factors was 3.1% and increased up to 60% in the presence of >3 risk factors. S-IE patients had higher rates of in-hospital mortality (54.4% vs. 28.7%; p < 0.001) and overall mortality at 1 year (66.3% vs. 45.6%; p < 0.001). Surgical treatment was not associated with improved outcomes in S-IE patients (in-hospital mortality: 46.2% in surgical vs. 58.1% in no surgical treatment; p = 0.47).ConclusionsStroke occurred in 1 of 10 patients with IE post-TAVR. A history of stroke, short time between TAVR and IE, vegetation size, valve prosthesis type, and residual aortic regurgitation determined an increased risk. The occurrence of stroke was associated with increased in-hospital and 1-year mortality rates, and surgical treatment failed to improve clinical outcomes.  相似文献   

16.
BackgroundTranscatheter aortic valve replacement (TAVR) is generally performed without control over the alignment of the bioprosthesis to the native aortic valve (AV) commissures. Data on the impact of commissural misalignment (CMA) on the clinical and hemodynamic outcome after TAVR are scarce.ObjectivesThe aim of this study was to investigate the impact of commissural misalignment (CMA) on the clinical and hemodynamic outcome in patients with severe tricuspid aortic stenosis undergoing TAVR using the balloon-expandable (BE) SAPIEN 3 valve (Edwards LifeSciences).MethodsClinical data of consecutive patients who underwent BE TAVR at Cedars-Sinai Medical Center (Los Angeles, California, USA) enrolled in the RESOLVE (Assessment of TRanscathetER and Surgical Aortic BiOprosthetic Valve Thrombosis and Its TrEatment With Anticoagulation) registry were retrospectively analyzed to evaluate CMA, which was defined as a neocommissure position >30° compared with native commissures on computed tomography.ResultsA total of 324 patients (36.6% female, median Society of Thoracic Surgeons score of 3.9%) were included in the analysis. CMA was present in 171 individuals (52.8%). At 30 days, rates of aortic regurgitation greater than mild (5.6%) and a residual AV gradient ≥20 mm Hg (7.4%) were not different between CMA and non-CMA patients. Commissural orientation was independently associated with a relative AV mean gradient increase >50% from discharge to 30 days (per increase of 10° misalignment; OR: 1.3; 95% CI: 1.0-1.4; P = 0.01). The long-term composite outcome of death or stroke was not different between groups (log-rank P = 0.29).ConclusionsIn patients with severe tricuspid aortic stenosis who undergo SAPIEN 3 TAVR, the neocommissures align randomly. Our data demonstrate that commissural alignment may impact device performance and clinical outcomes in patients undergoing BE TAVR. (Assessment of TRanscathetEr and Surgical Aortic BiOprosthetic VaLVve Dysfunction with Multimodality Imaging and Its TrEatment with Anticoagulation [RESOLVE]; NCT02318342)  相似文献   

17.
ObjectivesThis study sought to predict whether different methods of calculating the implantation depth (ID) influence clinical and hemodynamic outcome reporting in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expandable device.BackgroundDifferent approaches exist to calculate the ID, which may influence uniform and reliable reporting because the updated Valve Academic Research Consortium (VARC-2) criteria do not provide specific instructions.MethodsThe clinical and hemodynamic outcomes of 258 patients undergoing TAVR with a third-generation self-expandable device were analyzed with regard to the method used to assess the ID as follows: arithmetic mean, the arithmetic mean of the measured distances from the noncoronary cusp and the left coronary cusp to the distal prosthesis end; noncoronary cusp distance, the distance from the noncoronary cusp to the distal prosthesis end; and deepest edge, the deepest edge of the distal prosthesis end.ResultsRegardless of the measurement method, the optimal ID (OID) was reached in <30% (arithmetic mean, 25.4%; noncoronary cusp distance, 28.4%; deepest edge, 20.5%; p = 0.008). The deepest edge method is the most stringent to differentiate the relevant outcome parameters, such as the need for permanent pacemaker implantation (OID 3.7% vs. no OID 14.6%; p = 0.033). The hemodynamic outcome (i.e., mean pressure gradient reduction after TAVR: OID 7.4 ± 3.4 mm Hg vs. no OID 8.3 ± 4.0 mm Hg; p = 0.093) was not affected.ConclusionsThe OID was reached in <30% of TAVR procedures. The various methods applied for ID calculation significantly influence the outcome reporting and do not allow a uniform perception of the ID. (Multi Modal Cardiac Imaging Prior Transcatheter Aortic Valve Implantation; NCT01805739)  相似文献   

18.
BackgroundLoss of autonomy associated with nursing home admission (NHA) is a concern for patients. Yet the incidence of NHA after transcatheter aortic valve replacement (TAVR) is unknown.ObjectivesThe aim of this study was to investigate the incidence and factors associated with NHA following TAVR compared with the general population.MethodsThrough Danish registries, patients alive at discharge after TAVR were identified from January 2014 to October 2021. Patients were matched 1:5 on sex, age, and calendar year to the general population. The 3-year cumulative incidence and 95% CI of NHA were estimated using the Aalen-Johansen estimator, accounting for the competing risk for death. Through multivariate cause-specific Cox regression models, factors associated with NHA were examined.ResultsIn total, 5,312 TAVR patients were matched to 26,560 control subjects with a median age of 81 years and 56.1% males. Comorbidity burden was higher for TAVR patients. The 3-year cumulative incidence of NHA was 6.3% (95% CI: 5.5%-7.1%) for TAVR patients compared with 5.8% (95% CI: 5.4%-6.1%) for the general population. For TAVR patients >85 years of age, the cumulative incidence of NHA was 11.6% (95% CI: 9.5%-13.8%), and the risk for death was 23.3% (95% CI: 20.4%-26.2%). Factors associated with NHA were increasing age, frailty, living alone, and atrial fibrillation.ConclusionsTAVR was not associated with an increased incidence of NHA compared with the general population. Despite the increased incidence of NHA for TAVR patients >85 years of age, approximately 2 in 3 patients were still alive and not admitted to nursing homes 3 years after TAVR.  相似文献   

19.
ObjectivesThe aim of this study was to examine the predictive value of preprocedural computed tomography (CT)–based risk stratification of coronary obstruction during transcatheter aortic valve replacement (TAVR) on the basis of geometric measurements on postprocedural CT.BackgroundProper patient selection for additional procedures to prevent coronary obstruction during TAVR has not been adequately evaluated.MethodsPre- and postprocedural computed tomographic scans of 28 patients treated using bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) and TAVR were analyzed. Using the postprocedural computed tomographic images, threatened coronary obstruction (TCO) was defined as: 1) ostial obstruction (adherence of the transcatheter heart valve [THV] to the coronary ostium with leaflet extension above the ostium); and/or 2) sinus sequestration (THV adherence to the sinotubular junction [STJ] with leaflet extension above the STJ) and was substratified into complete and incomplete types.ResultsA total of 51 leaflets were evaluated (88% surgical tissue valves) after excluding leaflets not visible on CT (n = 5). On postprocedural CT, complete TCO was observed in 25.4% (13 of 51 leaflets). On preprocedural CT, leaflets were at high risk for complete TCO (incidence 53%) if the virtual THV–to–coronary distance (VTC) was <3.0 mm, or if the virtual THV–to–STJ distance (VTSTJ) was <1.0 mm with STJ height ? leaflet length <0 mm (leaflet-STJ mismatch). Leaflets were at low risk (incidence 0%) if the VTC was ≥3 mm and VTSTJ was ≥3.0 mm or STJ height ? leaflet length was ≥+2.0 mm. Of 28 leaflets treated using BASILICA, complete TCO was seen in 35.7% (n = 10), due to sinus sequestration (100%) with coexisting ostial obstruction (30%). Actual coronary events occurred in 7.1% (n = 2) because of leaflet prolapse, corresponding to an absolute risk reduction by BASILICA of 29% (P = 0.021).ConclusionsRisk assessment of coronary obstruction after TAVR may improve with a multiparametric approach incorporating VTC, VTSTJ, and leaflet-STJ mismatch. BASILICA appeared to reduce actual coronary events even in leaflets with anticipated coronary obstruction.  相似文献   

20.
ObjectivesThe aim of this study was to assess coronary accessibility after transcatheter aortic valve replacement (TAVR)–in–TAVR using multidetector computed tomography.BackgroundExpanding TAVR to patients with longer life expectancy may involve more frequent bioprosthetic valve failure and need for redo TAVR. Coronary access after TAVR-in-TAVR may be challenging, particularly as the leaflets from the initial transcatheter heart valve (THV) will form a neo-skirt following TAVR-in-TAVR.MethodsIn 45 patients treated with different combinations of CoreValve and Evolut (CV/EV) THVs with supra-annular leaflet position and SAPIEN THVs with intra-annular leaflet position, post-TAVR-in-TAVR multidetector computed tomographic scans were analyzed to examine coronary accessibility.ResultsAfter TAVR-in-TAVR, the coronary arteries originated below the top of the neo-skirt in 90% of CV/EV-first cases compared with 67% of SAPIEN-first cases (p = 0.009). For these coronary arteries originating below the top of the neo-skirt, the distance between the THV and the aortic wall was <3 mm in 56% and 25% of CV/EV-first and SAPIEN-first cases, respectively (p = 0.035). Coronary access may be further complicated by THV-THV stent frame strut misalignment in 53% of CV/EV-in-CV/EV cases. The risk for technically impossible coronary access was 27% and 10% in CV/EV-first and SAPIEN-first cases, respectively (p = 0.121). Absence of THV interference with coronary accessibility can be expected in 8% and 33% of CV/EV-first and SAPIEN-first cases, respectively (p = 0.005).ConclusionsCoronary access after TAVR-in-TAVR may be challenging in a significant proportion of patients. THVs with intra-annular leaflet position or low commissural height and large open cells may be preferable in terms of coronary access after TAVR-in-TAVR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号