首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ObjectivesThis study sought to compare patients with and without long-standing persistent atrial fibrillation (LSPAF) undergoing Watchman left atrial appendage (LAA) occlusion.BackgroundAn increased burden of atrial fibrillation is associated with progressive left atrial remodeling and enlargement.MethodsTransesophageal echocardiography (TEE) measures of LAA ostial diameter and depth, device compression, and residual leak were evaluated in 101 consecutive Watchman cases. The patients were categorized into LSPAF (n = 48) or non-LSPAF (n = 53) groups and compared.ResultsThe average LAA ostial diameter for LSPAF versus non-LSPAF by TEE omniplane at 0° was 21.1 ± 4.1 mm versus 18.2 ± 3.6 mm (p = 0.0002); at 45° was 18.7 ± 3.4 mm versus 16.3 ± 3.1 mm (p = 0.0004); at 90° was 19.6 ± 3.8 mm versus 16.2 ± 3.4 mm (p = 0.00001); and at 135° was 21.0 ± 4.1 mm versus 18.0 ± 4.1 mm (p = 0.0005). The average LAA depth for LSPAF versus non-LSPAF by TEE at 0° was 28.1 ± 6.4 mm versus 25.2 ± 4.9 mm (p = 0.02); at 45° was 27.9 ± 5.8 mm versus 25.1 ± 4.3 mm (p = 0.007); at 90° was 27.2 ± 5.2 mm versus 22.8 ± 3.7 mm (p = 0.0001); and at 135° was 25.6 ± 5.4 mm versus 21.5 ± 3.8 mm (p = 0.0001). In successfully treated patients, 77% of the LSPAF group received larger device (27, 30, or 33 mm) implants versus only 46% in the non-LSPAF group (p = 0.003). While both groups had similar rates of moderate (3 to 5 mm) leaks at implant (2% vs. 0%; p = 0.14), 27% of the LSPAF vs. 4% of the non-LSPAF group had moderate leaks (p = 0.04) on 6-week follow-up TEE.ConclusionsPatients with LSPAF have significantly larger LAA sizes, require larger devices, and have more residual leak on follow-up TEE. LSPAF may represent a higher risk group that warrants more stringent long-term follow-up.  相似文献   

2.
BackgroundWomen have higher rates of acute complications after left atrial appendage occlusion (LAAO). However, data on long-term safety and effectiveness are limited.ObjectivesThe aim of this study was to examine sex-specific short- and long-term outcomes after LAAO in the Amulet IDE (Amplatzer? Amulet? LAA Occluder) trial.MethodsThe following outcomes were compared between men and women: in-hospital complications, device-related outcomes (peridevice leak at 45 days and device-related thrombus at 18 months), and long-term clinical outcomes (death, thromboembolism, and bleeding). Subanalyses for the interaction between sex and device type were performed.ResultsA total of 1,833 patients underwent attempted device implantation (917 with the Amulet and 916 with the Watchman), of whom 734 were women (40%). Device success was 97.4% in men and 97.1% in women (P = 0.60). Rates of major in-hospital adverse events were higher in women (4.4% vs 1.9%; P < 0.01), driven by major bleeding (3.7% vs 1.0%; P < 0.01) and pericardial effusion requiring intervention (2.0% vs 0.5%; P < 0.01). Peridevice leak and device-related thrombus were similar in men and women (18.3% vs 18.9% [P = 0.78] and 3.3% vs 5.0% [P = 0.10], respectively). There were no differences between men and women in rates of ischemic stroke or systemic embolism (2.6% vs 2.6%; P = 0.98), transient ischemic attack (1.3% vs 1.6%; P = 0.69), hemorrhagic stroke (0.5% vs 0.4%; P = 0.88), major bleeding (10.1% vs 10.9%; P = 0.49), cardiovascular death (4.3% vs 3.5%; P = 0.45), or all-cause death (8.9% vs 6.9%; P = 0.16).ConclusionsIn the Amulet IDE trial, long-term clinical outcomes including effectiveness following LAAO were comparable in men and women despite the higher rates of in-hospital complications due to major bleeding and pericardial effusion in women. (Amplatzer? Amulet? LAA Occluder Trial [Amulet IDE]; NCT02879448)  相似文献   

3.
ObjectivesThe aim of this study was to assess the feasibility and efficacy of transcatheter leak closure with detachable coils in patients with incomplete left atrial appendage (LAA) closure.BackgroundIncomplete LAA closure is common after interventional therapies targeting the LAA, potentially hindering effective thromboembolic prevention. Detachable coils have found a wide range of applications for transcatheter vascular occlusion and embolization procedures.MethodsThirty consecutive patients at high thromboembolic risk with clinically relevant residual leaks (mean age 72 ± 9 years, 73.3% men, mean CHA2DS2-VASc score 4.4 ± 1.4, mean HAS-BLED score 3.6 ± 0.8) underwent percutaneous closure of the LAA patency using embolization coils. Transesophageal echocardiography was performed at 60 ± 15 days post-procedure.ResultsLAA closure had been previously attempted with the Watchman device in 25 patients, the Amulet device in 2 patients, and the LARIAT device in 3 patients. Baseline transesophageal echocardiography documented moderate and severe leaks in 20 (66.7%) and 10 (33.3%) patients, respectively. After a single procedure, 25 patients (83.3%) showed complete LAA sealing or minimal leaks. Five patients (16.7%) had moderate residual leaks; 3 patients of them were offered repeat procedures. Mean procedure and fluoroscopy times were 76 ± 41 min and 21 ± 14 min, respectively; the mean volume of iodinated contrast medium used was 80 ± 47 ml. Coil deployment was successful in all cases. The overall complication rate was 6.1%. After a median follow-up period of 54 days (range 43 to 265 days) and an average of 1.1 procedures/patient, transesophageal echocardiography revealed complete LAA sealing or negligible residual leaks in 28 patients (93.3%; 25 with no residual leak, 3 patients with minimal to mild residual leaks) and moderate residual leaks in 2 patients (6.7%).ConclusionsTranscatheter LAA leak occlusion using endovascular coils appears to be a safe, effective, and promising approach in patients at high echo time risk with incomplete LAA closure. (Transcatheter Leak Closure With Detachable Coils Following Incomplete Left Atrial Appendage Closure Procedures [TREASURE]; NCT03503253)  相似文献   

4.
BackgroundPeridevice leak (PDL) is a limitation of left atrial appendage occlusion.ObjectivesThe aim of this study was to assess the incidence of and outcomes associated with PDL in the Amulet IDE (AMPLATZER? Amulet? LAA Occluder Trial) randomized controlled trial.MethodsPatients with atrial fibrillation at increased stroke risk were randomly assigned to undergo either Amulet (dual occlusive mechanism) or Watchman 2.5 (single occlusive mechanism) device implantation. Transesophageal echocardiography was performed at 45 days and 12 months postprocedure. Clinically significant PDL was defined as ≥3 mm. The primary endpoint was ischemic stroke or systemic embolism, and the secondary endpoint was stroke, systemic embolism, or cardiovascular death. The Kaplan-Meier method was used to estimate 18-month cumulative event rates landmarked at day 45 postprocedure.ResultsA total of 1,593 patients underwent successful left atrial appendage occlusion and had an evaluable transesophageal echocardiographic studies at 45 days. The dual–occlusive mechanism device provided superior closure (defined as leak <3 mm) compared with the single–occlusive mechanism device at 45 days (88.9% vs 74.1%; P < 0.01) and 12 months (90.5% vs. 78.3%; P < 0.01). Through 18 months, PDL was associated with a higher, but not statistically significant, risk for the primary endpoint (3.6% vs 1.8%; adjusted HR: 1.98; 95% CI: 0.93-4.19; P = 0.07) and a statistically significantly higher risk for the secondary endpoint (8.1% vs. 4.7%; adjusted HR: 1.66; 95% CI: 1.02-2.69; P = 0.04).ConclusionsThe dual–occlusive mechanism device provided superior closure compared with the single–occlusive mechanism device at both 45 days and 1 year postprocedure. PDL ≥3 mm was associated with a significantly increased 18-month risk for the composite of stroke, systemic embolism, or cardiovascular death. Completeness of closure of the left atrial appendage has important implications for patient outcomes. (AMPLATZER? Amulet? LAA Occluder Trial [Amulet IDE]; NCT02879448)  相似文献   

5.
BackgroundIncomplete left atrial appendage (LAA) closure is an evolving topic of clinical significance and thromboembolic potential, with recent long-term studies suggesting lower cutoffs for relevant leak size.ObjectivesThe aim of this prospective observational study was to assess 3 different closure techniques for persistent peridevice leaks after incomplete LAA closure and compare their efficacy and safety outcomes.MethodsWe studied 160 patients (mean age 72 ± 9 years; 71% men) who underwent 1 of the 3 available modalities (detachable embolization coils, vascular plugs or septal occluders, and radiofrequency ablation) for residual central or eccentric leak closure. Both acute postprocedural success (closure or <1-mm leak at the end of the procedure) and closure at 1-year follow-up transesophageal echocardiography imaging were evaluated.ResultsOf 160 patients, 0.6%, 41.3%, and 58.1% had mild (1-2 mm), moderate (3-5 mm), and severe (≥5 mm) leaks, respectively. Baseline LAA closure type was 72.5% Watchman FLX, 16.3% Lariat, 5.6% surgical ligation, 1.9% AtriClip, and 1.9% Amulet. Successful closure (0- or <1-mm leak) was seen in 100% of patients in all cohorts following intervention, with overall complete closure (0-1 mm) or mild or minimal leaks (1-2 mm) on 1-year follow-up transesophageal echocardiography seen in 100% of the atrial septal occluder or vascular plug cohort, 85.9% of the coil cohort, and 83.3% of the radiofrequency ablation cohort (P < 0.001). Two patients (1.3%) experienced cardiac tamponade, and there were no deaths or other complications.ConclusionsPeridevice leaks can safely and effectively be closed using 3 different modalities depending on size and location.  相似文献   

6.
BackgroundDespite the widespread use of transesophageal echocardiography (TEE) to guide structural cardiac interventions, studies evaluating safety in this context are lacking.ObjectivesThis study sought to determine the incidence, types of complications, and factors associated with esophageal or gastric lesions following TEE manipulation during structural cardiac interventions.MethodsThis was a prospective study including 50 patients undergoing structural cardiac interventions in which TEE played a central role in guiding the procedure (mitral and tricuspid valve repair, left atrial appendage closure, and paravalvular leak closure). An esophagogastroduodenoscopy (EGD) was performed before and immediately after the procedure to look for new injuries that might have arisen during the course of the intervention. Patients were divided in 2 cohorts according to the type of injury: complex lesions (intramural hematoma, mucosal laceration) and minor lesions (petechiae, ecchymosis). The factors associated with an increased risk of complications were assessed.ResultsPost-procedural EGD showed a new injury in 86% (n = 43 of 50) of patients, with complex lesions accounting for 40% (n = 20 of 50) of cases. Patients with complex lesions presented more frequently with an abnormal baseline EGD (70% vs. 37%; p = 0.04) and had a higher incidence of post-procedural dysphagia or odynophagia (40% vs. 10%; p = 0.02). Independent factors associated with an increased risk of complex lesions were a longer procedural time under TEE manipulation (for each 10-min increment in imaging time, odds ratio: 1.27; 95% confidence interval: 1.01 to 1.59) and poor or suboptimal image quality (odds ratio: 4.93; 95% confidence interval: 1.10 to 22.02).ConclusionsMost patients undergoing structural cardiac interventions showed some form of injury associated with TEE, with longer procedural time and poor or suboptimal image quality determining an increased risk. Imaging experts performing this technique should be aware of the nature of potential complications, to take the necessary precautions to prevent their occurrence and facilitate early diagnosis and treatment.  相似文献   

7.
ObjectivesThe authors present a novel technique to detect and characterize LAA thrombus in humans using combined positron emission tomography (PET)/cardiac magnetic resonance (CMR) of a fibrin-binding radiotracer, [64Cu]FBP8.BackgroundThe detection of thrombus in the left atrial appendage (LAA) is vital in the prevention of stroke and is currently performed using transesophageal echocardiography (TEE).MethodsThe metabolism and pharmacokinetics of [64Cu]FBP8 were studied in 8 healthy volunteers. Patients with atrial fibrillation and recent TEEs of the LAA (positive n = 12, negative n = 12) were injected with [64Cu]FBP8 and imaged with PET/CMR, including mapping the longitudinal magnetic relaxation time (T1) in the LAA.Results[64Cu]FBP8 was stable to metabolism and was rapidly eliminated. The maximum standardized uptake value (SUVMax) in the LAA was significantly higher in the TEE-positive than TEE-negative subjects (median of 4.0 [interquartile range (IQR): 3.0-6.0] vs 2.3 [IQR: 2.1-2.5]; P < 0.001), with an area under the receiver-operating characteristic curve of 0.97. An SUVMax threshold of 2.6 provided a sensitivity of 100% and specificity of 84%. The minimum T1 (T1Min) in the LAA was 970 ms (IQR: 780-1,080 ms) vs 1,380 ms (IQR: 1,120-1,620 ms) (TEE positive vs TEE negative; P < 0.05), with some overlap between the groups. Logistic regression using SUVMax and T1Min allowed all TEE-positive and TEE-negative subjects to be classified with 100% accuracy.ConclusionsPET/CMR of [64Cu]FBP8 is able to detect acute as well as older platelet-poor thrombi with excellent accuracy. Furthermore, the integrated PET/CMR approach provides useful information on the biological properties of thrombus such as fibrin and methemoglobin content. (Imaging of LAA Thrombosis; NCT03830320)  相似文献   

8.
ObjectivesThis study sought to report the incidence, characteristics, and clinical impact of device-related thrombus (DRT) following left atrial appendage occlusion (LAAO) with the AMPLATZER Amulet device (Abbott, Plymouth, Minnesota).BackgroundDRT is a potential serious complication of LAAO, but the incidence and clinical impact of DRTs in a real-world setting are not well characterized.MethodsA total of 1,088 patients were enrolled in a multicenter prospective study and followed for 1 year. All events were adjudicated by an independent committee, including the presence of DRT. Patients with DRT were reviewed for suboptimal device implantation and characterization of DRT formation. Multiple Cox regression was performed to identify predictors of DRT formation.ResultsDevice implantation was successful in 1,078 (99%) patients, with 1-year follow-up completed in 96.3% of patients. A total of 18 DRTs occurred in 17 patients (1.7%/year), as a second DRT developed following complete resolution of an initial DRT in 1 patient. The left upper pulmonary vein ridge was not covered by the Amulet disc in 82% of DRT patients, indicating suboptimal implantation, with most thrombus developing in the untrabeculated area of the LAA ostium between the pulmonary vein ridge and the upper edge of the disc. Three (18%) DRT patients had an ischemic stroke, all within 3 months of DRT diagnosis. Patients with a DRT were at a greater risk for ischemic stroke or transient ischemic attack compared with non-DRT patients (hazard ratio: 5.27; 95% confidence interval: 1.58 to 17.55; p = 0.007). Larger LAA orifice width was a predictor of DRT formation (hazard ratio: 1.09; 95% confidence interval: 1.00 to 1.19; p = 0.04).ConclusionsFollowing LAAO with the AMPLATZER Amulet device, DRT was observed infrequently. Although the presence of DRT was associated with an increased rate of ischemic stroke or transient ischemic attack as compared with patients without DRT, the large majority of DRT patients (82%) did not experience any ischemic neurologic events.  相似文献   

9.
ObjectivesThe aim of this study was to compare outcomes among patients from the PROTECT-AF (WATCHMAN Left Atrial Appendage System for Embolic PROTECTion in Patients With Atrial Fibrillation) and PREVAIL (Evaluation of the WATCHMAN Left Atrial Appendage [LAA] Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy) left atrial appendage occlusion (LAAO) trials with matched patients from the National Cardiovascular Data Registry LAAO Registry using patient-level data.BackgroundPatients undergoing LAAO in clinical practice generally have more comorbidities than trial participants.MethodsPropensity-matched analyses, with up to 3 registry patients matched to each trial patient, were performed using Cox proportional hazards and Fine-Gray models.ResultsA total of 1,904 registry patients were matched to 667 trial LAAO patients; 1,010 registry patients were matched to 348 warfarin patients. Compared with registry patients, trial LAAO patients experienced more pericardial effusion requiring intervention (3.8% vs 0.6%, P < 0.001), periprocedural ischemic stroke (0.9% vs 0.2%, P = 0.005), and failed device implantation (7.5% vs 3.6%, P < 0.001). The 425-day risk of ischemic stroke in trial LAAO patients was higher than in registry patients (2.70% vs 1.21%; HR: 1.951; P = 0.03); warfarin patients had comparable rates of ischemic stroke compared with registry patients (1.15% vs 1.29%; HR: 0.728; P = 0.57). Hemorrhagic stroke risk was similar among trial LAAO and registry patients (P = 0.88). Hemorrhagic stroke risk was greater among warfarin patients versus registry patients (1.44% vs 0.20%; HR: 5.871, P = 0.03). Mortality was lower in trial LAAO patients than in registry patients (2.92% vs 6.23%; HR: 0.477; P = 0.004), a difference attributable to noncardiovascular deaths. Mortality was similar (P = 0.44) among trial warfarin (4.48%) and registry (5.86%) patients.ConclusionIn clinical practice, patients who meet trial criteria and undergo LAAO experience a lower risk of ischemic stroke, a similar risk of hemorrhagic stroke, and a higher risk of death after implant versus LAAO trial patients. (WATCHMAN Left Atrial Appendage System for Embolic PROTECTion in Patients With Atrial Fibrillation [PROTECT-AF], NCT00129545; Evaluation of the WATCHMAN Left Atrial Appendage [LAA] Closure Device in Patients With Atrial Fibrillation Versus Long Term Warfarin Therapy [PREVAIL], NCT01182441)  相似文献   

10.
ObjectivesThis study sought to report early experience with the new-generation Watchman FLX device (Boston Scientific, Marlborough, Massachusetts).BackgroundThe new-generation Watchman FLX features a reduced height, improved anchoring and fabric coverage, and a closed distal end. These design modifications aim to simplify implantation, allow full recapture and repositioning, and reduce peridevice leak and device-related thrombosis.MethodsA total of 165 patients undergoing left atrial appendage (LAA) occlusion (LAAO) with Watchman FLX were enrolled in a prospective, multicenter registry at 12 centers participating in the European limited market release program.ResultsMean age was 75.4 ± 8.9 years, and CHA2DS2-VASc score 4.4 ± 1.4. A total of 128 patients (77.6%) had a history of major bleeding, including previous intracranial hemorrhage in 55 cases (33.3%). LAA landing zone minimal and maximal mean diameters were 19.1 ± 3.6 mm and 22.3 ± 3.7 mm, and 24.2% of LAA were considered complex by dimensions. Technical success was achieved in all patients. Successful implantation at first attempt was achieved in 129 cases (78.2%), and a second device was required in 6 cases (3.6%). Procedure-related complications occurred in 3 patients (1.8%): 2 access-related (1.2%) and 1 pericardial effusion (0.6%). No peri-procedural strokes, deaths, or device embolizations occurred. Forty-nine patients (29.7%) were discharged with single antiplatelet therapy, 105 (63.6%) on dual antiplatelet, and 11 (6.7%) on anticoagulation. Imaging follow-up displayed just 1 peridevice leak ≥5 mm and 7 cases of device-related thrombosis (4.7%). During a median follow-up of 55 days (interquartile range: 45 to 148 days), there were 6 hemorrhagic complications (4.8%), 1 patient (0.8%) had an ischemic stroke, and 1 (0.8%) died. No late device embolizations occurred.ConclusionsLAAO with the Watchman FLX is safe and effective in a wide range of LAA morphologies, with a low procedural complication rate, high degree of LAA sealing, and favorable short-term efficacy.  相似文献   

11.
ObjectivesThe goal of this study was to evaluate whether the beneficial effect of use of intravascular ultrasound (IVUS) is sustained for long-term follow-up.BackgroundThe use of IVUS promoted favorable 1-year clinical outcome in the IVUS-XPL (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions) trial. It is not known, however, whether this effect is sustained for long-term follow-up.MethodsThe IVUS-XPL trial randomized 1,400 patients with long coronary lesions (implanted stent length ≥28 mm) to receive IVUS-guided (n = 700) or angiography-guided (n = 700) everolimus-eluting stent implantation. Five-year clinical outcomes were investigated in patients who completed the original trial. The primary outcome was the composite of major adverse cardiac events, including cardiac death, target lesion–related myocardial infarction, or ischemia-driven target lesion revascularization at 5 years, analyzed by intention-to-treat.ResultsFive-year follow-up was completed in 1,183 patients (85%). Major adverse cardiac events at 5 years occurred in 36 patients (5.6%) receiving IVUS guidance and in 70 patients (10.7%) receiving angiographic guidance (hazard ratio: 0.50; 95% confidence interval: 0.34 to 0.75; p = 0.001). The difference was driven mainly by a lower risk for target lesion revascularization (31 [4.8%] vs. 55 [8.4%]; hazard ratio: 0.54; 95% confidence interval: 0.33 to 0.89; p = 0.007). By landmark analysis, major adverse cardiac events between 1 and 5 years occurred in 17 patients (2.8%) receiving IVUS guidance and in 31 patients (5.2%) receiving angiographic guidance (hazard ratio: 0.53; 95% confidence interval: 0.29 to 0.95; p = 0.031).ConclusionsCompared with angiography-guided stent implantation, IVUS-guided stent implantation resulted in a significantly lower rate of major adverse cardiac events up to 5 years. Sustained 5-year clinical benefits resulted from both within 1 year and from 1 to 5 years post-implantation. (Impact of Intravascular Ultrasound Guidance on the Outcomes of Xience Prime Stents in Long Lesions [IVUS-XPL Study]: Retrospective and Prospective Follow-Up Study; NCT03866486)  相似文献   

12.
ObjectivesThe aim of this study was to evaluate the impact of CHA2DS2-VASc and HAS-BLED scores on ischemic and bleeding events of patients enrolled in the Amplatzer Amulet Observational Study.BackgroundBaseline CHA2DS2-VASc and HAS-BLED scores have been validated in atrial fibrillation patients to guide about anticoagulation but not in patients treated by left atrial appendage occlusion (LAAO).MethodsSubjects were stratified according to CHA2DS2-VASc and HAS-BLED scores. Clinical outcomes were collected through 2 years and adjudicated by an independent committee.ResultsSubjects were considered at low (n = 156), moderate (n = 715), and high (n = 215) risk for ischemic stroke, corresponding to CHA2DS2-VASc scores of <3, 3 to 5, and ≥6, respectively. The annual rates of ischemic stroke were 1.1%, 2.0%, and 3.5%, respectively. When compared with the predicted rate, LAAO reduced the risk of ischemic stroke by 56%, 69%, and 68%. Device-related thrombus occurred in 0.7%, 1.5%, and 3.0% of subjects at low, moderate, and high risk for ischemic stroke, respectively. The HAS-BLED score was ≤3 in 629 subjects and >3 in 456 subjects, respectively. Non-peri-procedural major bleeding was reduced by 11% and 9% compared with predicted rates in the low and high bleeding risk groups, respectively.ConclusionsLAAO with the Amplatzer Amulet reduced the risk of ischemic stroke compared with the predicted rate, with a greater magnitude among patients at high thromboembolic risk without increasing the bleeding risk. (Amplatzer™Amulet™ Post-Market Study [Amulet™PMS]; NCT02447081)  相似文献   

13.
BackgroundSome chronic obstructive pulmonary disease (COPD) patients develop hypoxemia with disease progression, with some even requiring long-term oxygen therapy (LTOT). Lung function, especially diffusing capacity, and the annual decline in PaO2, are reported to be predictive factors of chronic respiratory failure. However, the association between lung morphometry evaluated using computed tomography (CT) images and LTOT initiation is unknown.MethodsWe retrospectively evaluated the relationship between clinical indices, including pulmonary function, body mass index (BMI), and CT parameters, at baseline and LTOT initiation in two prospective COPD cohorts. In the Nara Medical University cohort (n = 76), the low attenuation area (LAA) and its fractal dimension (fractal D) were adapted as the indices for parenchymal destruction in CT images. The association between these CT measurements and LTOT initiation was replicated in the Kyoto University cohort (n = 130).ResultsIn the Nara Medical University cohort, lower BMI (hazard ratio [HR]:0.70, p = 0.006), lower % diffusing capacity (%DLCO) (HR: 0.92, p = 0.006), lower %DLCO/VA (HR, 0.90, p = 0.008), higher RV/TLC (HR, 1.26, p = 0.012), higher LAA% (HR: 1.18, p = 0.001), and lower fractal D (HR: 3.27 × 10?8, p < 0.001) were associated with LTOT initiation. Multivariate analysis in the Kyoto University cohort confirmed that lower %DLCO and lower fractal D were independently associated with LTOT initiation, whereas LAA% was not.ConclusionFractal D, which is the index for morphometric complexity of LAA in CT analysis, is predictive of LTOT initiation in COPD patients.  相似文献   

14.
ObjectivesThe aim of this study was to evaluate the 2-year performance of a polymer-based drug-eluting stent (DES) for the treatment of complex femoropopliteal lesions.BackgroundDespite the promising early outcomes of the Eluvia DES, the long-term safety and efficacy of the device in a real-world scenario remain unclear.MethodsBetween March 2016 and December 2018, 130 patients (137 lesions) with symptomatic femoropopliteal disease were included in this study. The primary outcome measure of this analysis was primary patency. Secondary patency, freedom from target lesion revascularization, freedom from surgical conversion, and overall mortality and morbidity were additionally analyzed.ResultsThe majority of patients presented with lifestyle-limiting claudication (n = 90 [69%]). The mean lesion length was 194 ± 108 mm, 74% of the lesions (n = 101) were chronic total occlusions, and 72% (n = 99) were calcified. Moderate to severe calcification (Peripheral Arterial Calcium Scoring Scale score 3 or 4) was observed in 48% of the treated vessels (n = 67). At 24 months, the Kaplan-Meier estimate of primary patency was 71%, whereas both the secondary patency rate and freedom from target lesion revascularization were 80%. Overall survival amounted to 85%. Freedom from major amputation was 98%, while freedom from surgical conversion was 89%. Degeneration of the vessel wall was observed in 27 lesions (20%).ConclusionsIn this study, use of the Eluvia polymer-based DES for the treatment of complex femoropopliteal disease showed promising 2-year results. Nonetheless, a relatively high rate of vessel wall degeneration was observed after DES deployment.  相似文献   

15.
Background and aimsThere is accumulating evidence that gut microbiota plays a key role in cardiovascular diseases. Gut bacteria can transform dietary choline, l-carnitine, and trimethylamine N-oxide (TMAO) into trimethylamine, which can be oxidized into TMAO again in the liver. However, the alterations of the gut microbiota in large artery atherosclerotic (LAA) stroke and cardioembolic (CE) stroke have been less studied.Methods and resultsWe performed a case–control study in patients with LAA and CE types of strokes. We profiled the gut microbiome using Illumina sequencing of the 16S ribosomal RNA gene (V4–V5 regions), and TMAO was determined via liquid chromatography–tandem mass spectrometry. Our results showed that the TMAO levels in the plasma of patients with LAA and CE strokes were significantly higher than those in controls (LAA stroke, 2931 ± 456.4 ng/mL; CE stroke, 4220 ± 577.6 ng/mL; healthy control, 1663 ± 117.8 ng/mL; adjusted p < 0.05). The TMAO level in the plasma of patients with LAA stroke was positively correlated with the carotid plaque area (rho = 0.333, 95% CI = 0.08–0.55, p = 0.0093). Notably, the composition and the function of gut microbiota in the LAA stroke group were significantly different from those in the control group (FDR-adjusted p-value < 0.05). There was no significant association between gut microbiota and CE stroke in our study.ConclusionThis study provides evidence for significant compositional and functional alterations of the gut microbiome in patients with LAA stroke. Gut microbiota might serve as a potential biomarker for patients with LAA stroke.  相似文献   

16.
BackgroundIt remains unknown whether the noninvasive evaluation of the degree of amyloid deposition in the myocardium can predict the prognosis of patients with light chain (AL) cardiac amyloidosis.ObjectivesThe purpose of this study was to demonstrate that 11C-Pittsburgh B compound positron emission tomography (11C-PiB PET) is useful for prognostication of AL cardiac amyloidosis by noninvasively imaging the myocardial AL amyloid deposition.MethodsThis study consecutively enrolled 41 chemotherapy-naïve AL cardiac amyloidosis patients. The amyloid deposit was quantitatively assessed with amyloid P immunohistochemistry in endomyocardial biopsy specimens and was compared with the degree of myocardial 11C-PiB uptake on PET. The primary endpoint was a composite of all-cause death, heart transplantation, and acute decompensated heart failure.ResultsThe degree of myocardial 11C-PiB PET uptake was significantly higher in the cardiac amyloidosis patients compared with normal subjects and correlated well with the degree of amyloid deposit on histology (R2 = 0.343, p < 0.001). During follow-up (median: 423 days, interquartile range: 93 to 1,222 days), 24 patients experienced the primary endpoint. When the cardiac amyloidosis patients were divided into tertiles by the degree of myocardial 11C-PiB PET uptake, patients with the highest PiB uptake experienced the worst clinical event-free survival (log-rank p = 0.014). The degree of myocardial PiB PET uptake was a significant predictor of clinical outcome on multivariate Cox regression analysis (adjusted hazard ratio: 1.185; 95% confidence interval: 1.054 to 1.332; p = 0.005).ConclusionsThese proof-of-concept results show that noninvasive evaluation of myocardial amyloid load by 11C-PiB PET reflects the degree of amyloid deposit and is an independent predictor of clinical outcome in AL cardiac amyloidosis patients.  相似文献   

17.
BackgroundThromboendarterectomy (TEA) is the gold-standard treatment for common femoral artery (CFA). However, because of its low invasiveness and short hospitalization duration, CFA endovascular therapy (EVT) is performed in real-world practice. However, the clinical benefits and appropriate target population for CFA EVT remain unclear.ObjectivesThe aims of this study were to compare the clinical outcomes of TEA with those of EVT in patients with symptomatic CFA diseases and to identify the adequate target population for CFA EVT.MethodsA total of 1,193 consecutive patients who underwent EVT (n = 761) or TEA (n = 432) for CFA were identified and retrospectively reviewed from a registry of 66 institutions. The primary outcome was 1-year primary patency compared between EVT and TEA using propensity score matching. An interaction analysis was performed to explore the appropriate target population for CFA EVT.ResultsAfter propensity score matching, the 1-year primary patency rate was significantly higher in the TEA group (82.3% vs 96.6%; P < 0.001), whereas perioperative complications were more frequently observed in the TEA group (P = 0.047). Nonambulatory status attenuated the HR of EVT vs TEA for restenosis risk (P = 0.021), whereas the presence of nodular calcification significantly increased the HR (P = 0.040). In the EVT subgroup analysis for restenosis risk, stent use showed the lowest HR compared with plain balloon angioplasty and drug-coated balloon angioplasty (P < 0.001).ConclusionsTEA showed superior 1-year patency compared with EVT in a nationwide multicenter study. Nonambulatory status attenuated the superiority, whereas the presence of nodular calcification enhanced it.  相似文献   

18.
ObjectivesThis study sought to investigate clinical outcomes associated with left atrial appendage occlusion (LAAO) versus direct oral anticoagulants (DOACs) in patients with high-risk atrial fibrillation (AF).BackgroundLAAO has been shown to be noninferior to warfarin for stroke prevention in AF. However, anticoagulation with DOACs is now preferred over warfarin as thromboprophylaxis in AF.MethodsPatients with AF enrolled in the Amulet Observational Registry (n = 1,088) who had successful LAAO with the Amplatzer Amulet device (n = 1,078) were compared with a propensity score–matched control cohort of incident AF patients (n = 1,184) treated by DOACs identified from Danish national patient registries. Propensity score matching was based on the covariates of the CHA2DS2-VASc (congestive heart failure, hypertension, age ≥75 years, diabetes mellitus, prior stroke or transient ischemic attack or thromboembolism, vascular disease, age 65–74 years, sex category) and HAS-BLED (hypertension, abnormal renal or liver function, stroke, bleeding, labile international normalized ratio, elderly, drugs or alcohol) scores for predicting stroke and bleeding. The primary outcome was a composite of ischemic stroke, major bleeding (Bleeding Academic Research Consortium ≥3), or all-cause mortality, and follow-up was 2 years.ResultsAF patients treated with LAAO had a significantly lower risk of the primary composite outcome as compared with patients treated with DOACs (hazard ratio [HR]: 0.57; 95% confidence interval [CI]: 0.49 to 0.67). Total events and event rates per 100 patient-years were (LAAO vs. DOACs) 256 vs. 461 and 14.5 vs. 25.7, respectively. The risk of ischemic stroke was comparable between groups (HR: 1.11; 95% CI: 0.71 to 1.75), while risk of major bleeding (HR: 0.62; 95% CI: 0.49 to 0.79) and all-cause mortality (HR: 0.53; 95% CI: 0.43 to 0.64) were significantly lower in patients treated with LAAO.ConclusionsAmong high-risk AF patients, LAAO in comparison with DOACs may have similar stroke prevention efficacy but lower risk of major bleeding and mortality.  相似文献   

19.
ObjectivesThis study assessed the impact of right-atrial (RA) pacing on left-atrial (LA) physiology and clinical outcome.BackgroundData for the effects of RA pacing on LA synchronicity, function, and structure after cardiac resynchronization therapy (CRT) are scarce.MethodsThe effect of RA pacing on LA function, morphology, and synchronicity was assessed in a prospective imaging cohort of heart failure (HF) patients in sinus rhythm with a guideline-based indication for CRT. Additionally, in a retrospective outcome cohort of consecutive HF patients undergoing CRT implantation, the relationship to RA pacing was assessed using various outcome endpoints. High versus low atrial pacing burden was defined as atrial pacing above or below 50% in both cohorts.ResultsA total of 36 patients were included in the imaging cohort (68 ± 11 years of age). Six months after CRT, patients with high RA pacing burden showed less improvement in LA maximum and minimum volumes and total emptying fraction (p < 0.05). Peak atrial longitudinal strain and reservoir and booster strain rates but not conduit strain rate improved after CRT in patients with low RA pacing burden but worsened in patients with high RA pacing burden (p < 0.05 for all). A high RA pacing burden induced significant intra-atrial dyssynchrony (maximum opposing wall delay: 44 ± 13 ms vs. 97 ± 17 ms, respectively; p = 0.022). A total of 569 patients were included in the outcome cohort. After covariate adjustments were made, a high RA pacing burden was associated with reduced LV reverse remodeling (β = 8.738; 95% confidence interval [CI]: 3.101 to 14.374; p = 0.002) and new-onset or recurrent atrial fibrillation (41% vs. 22%, respectively, at a median of 31 months [range 22 to 44 months follow-up]; p < 0.001). There were no differences in time to first HF hospitalization or all-cause mortality (p = 0.185) after covariate adjustment. However, in a recurrent event analysis, HF readmissions were more common in patients exposed to a high RA pacing burden (p = 0.003).ConclusionsRA pacing in CRT patients negatively influences LA morphology, function, and synchronicity, which is associated with worse clinical outcome, including diminished LV reverse remodeling, increased risk for new-onset or recurrent AF and heart failure readmission. Strategies reducing RA pacing burden may be warranted.  相似文献   

20.
ObjectivesA large comprehensive analysis of transcatheter aortic valve replacement (TAVR) was performed for failed stentless bioprostheses.BackgroundValve-in-valve (ViV) transcatheter aortic replacement (TAVR) is an alternative to redo surgery for patients with a failing aortic bioprosthesis.MethodsUnadjusted outcome data were collected from the VIVID (Valve-in-Valve International Data) registry between 2007 and 2016 from a total of 1,598 aortic ViV procedures (291 stentless, 1,307 stented bioprostheses).ResultsBioprosthetic failure was secondary to aortic regurgitation in 56% of stentless and 20% stented devices (p < 0.001). ViV-TAVR access was transfemoral in 71.1% stentless and 74.2% stented ViV-TAVR. Self-expanding devices were more frequently used in stentless ViV-TAVR (56.0% vs. 39.9%; p = 0.05), but there was no difference between balloon-expanding and self-expanding TAVR devices for stented ViV-TAVR (48.6% vs. 45.1%). The degree of oversizing for all mechanisms of bioprosthesis failure was 9 ± 10% for stentless ViV-TAVR vs. 6 ± 9% for stented ViV-TAVR (and 8 ± 10% for stentless ViV-TAVR vs. 3 ± 9% for stented ViV-TAVR in patients with predominant aortic regurgitation; both p < 0.001). Initial device malposition (10.3% vs. 6.2%; p = 0.014), second transcatheter device (7.9% vs. 3.4%), coronary obstruction (6.0% vs. 1.5%), and paravalvular leak occurred more frequently in stentless ViV-TAVR (all p < 0.001). Hospital stay duration (median 7 days) was no different, and 30-day (6.6% vs. 4.4%; p = 0.12) and 1-year mortality year (15.8% vs. 12.6%; p = 0.15) were numerically higher, but not statistically different, after stentless ViV-TAVR.ConclusionsStentless ViV-TAVR is associated with greater periprocedural complications (initial device malposition, second transcatheter device, coronary obstruction, paravalvular leak), but no difference in 30-day and 1-year outcome.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号