首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND: The purpose of this study was to evaluate the stabilizing effect of radial head replacement in cadaver elbows with a deficient medial collateral ligament. METHODS: Passive elbow flexion with the forearm in neutral rotation and in 80 degrees of pronation and supination was performed under valgus and varus loads (1) in intact elbows, (2) after a surgical approach (lateral epicondylar osteotomy of the distal part of the humerus), (3) after release of the anterior bundle of the medial collateral ligament, (4) after release of the anterior bundle of the medial collateral ligament and resection of the radial head, and (5) after subsequent replacement of the radial head with each of three different types of radial head prostheses (a Wright monoblock titanium implant, a KPS bipolar Vitallium [cobalt-chromium]-polyethylene implant, and a Judet bipolar Vitallium-polyethylene-Vitallium implant) in the same cadaver elbow. Total valgus elbow laxity was quantified with use of an electromagnetic tracking device. RESULTS: The mean valgus laxity changed significantly (p < 0.001) as a factor of constraint alteration. The greatest laxity was observed after release of the medial collateral ligament together with resection of the radial head (11.1 degrees +/- 5.6 degrees). Less laxity was seen following release of the medial collateral ligament alone (6.8 degrees +/- 3.4 degrees), and the least laxity was seen in the intact state (3.4 degrees +/- 1.6 degrees). Forearm rotation had a significant effect (p = 0.003) on valgus laxity throughout the range of flexion. The laxity was always greater in pronation than it was in neutral rotation or in supination. The mean valgus laxity values for the elbows with a deficient medial collateral ligament and an implant were significantly greater than those for the medial collateral ligament-deficient elbows before radial head resection (p < 0.05). The implants all performed similarly except in neutral forearm rotation, in which the elbow laxity associated with the Judet implant was significantly greater than that associated with the other two implants. CONCLUSIONS AND CLINICAL RELEVANCE: This study showed that a bipolar radial head prosthesis can be as effective as a solid monoblock prosthesis in restoring valgus stability in a medial collateral ligament-deficient elbow. However, none of the prostheses functioned as well as the native radial head, suggesting that open reduction and internal fixation to restore radial head anatomy is preferable to replacement when possible.  相似文献   

2.
The GSB III elbow prosthesis is a loose-hinged type of elbow implant. The introduction of such hinged elbow arthroplasty expanded the indications for elbow replacement to patients with more deficient bone and ligaments. The purpose of this study was to compare the kinematics and stability of the GSB III elbow prosthesis with that of the normal elbow and to investigate the role of the collateral ligaments in the kinematics and the stability of the GSB III total elbow prosthesis in an in vitro model. The results could show a semiconstrained kinematic pattern of the GSB III implant. The mean laxity for varus/valgus stress of the implant without collateral ligament support was significantly greater for all flexion angles when compared with intact elbows (mean, 12.7 degrees versus 5.4 degrees ) and with elbows treated with a standard implantation technique (mean, 9.5 degrees ). The release of the collateral ligaments increased the already observed varus shift after standard implantation of a GSB III elbow prosthesis. The laxity measured without collateral ligaments during loaded movement reached the maximum varus/valgus laxity of the GSB III prosthesis of 12 degrees degrees. The study confirms the role of the collateral ligaments in stabilizing the GSB III elbow prosthesis. Missing collateral ligaments may overload the implant-cement-bone interface and may be one factor contributing to early aseptic loosening of this device.  相似文献   

3.
We investigated the effect of simulated muscle loading and the contribution of the radial head to stability of the Norway elbow in 6 cadavers using an electromagnetic tracking device. The kinematics of the elbow after implantation of the prosthesis were similar to the intact elbow in their valgus-varus orientation, however, the forearms were slightly externally rotated, probably due to a small amount of external rotation of the humeral components at the time of implantation. The valgus-varus laxity limit of the implants were greater than in the intact specimens averaging 8.0 and 5.6 degrees, respectively. Simulated muscle loading stabilized both the intact and the Norway elbows. Excision of the radial head after implant arthroplasty increased their valgus-varus laxity, suggesting that preservation of the radial head may be indicated if it is not too severely involved by the underlying disease process.

The laxity permitted by the prosthesis articulation is greater than that measured after implantation of the Norway arthroplasty. This suggests that the prosthesis may behave as an unconstrained arthroplasty. This should minimize the stress experienced by the bone-cement interface and may reduce the incidence of loosening. The laxity of the elbows after joint arthroplasty were only slightly greater than normal, possibly explaining the low incidence of prosthesis dislocation which has been observed with clinical use.  相似文献   

4.
BACKGROUND: Radial head fractures are common injuries. Comminuted radial head fractures often are treated with radial head excision with or without radial head arthroplasty. The purpose of the present study was to determine the effect of radial head excision and arthroplasty on the kinematics and stability of elbows with intact and disrupted ligaments. We hypothesized that elbow kinematics and stability would be (1) altered after radial head excision in elbows with intact and disrupted ligaments, (2) restored after radial head arthroplasty in elbows with intact ligaments, and (3) partially restored after radial head arthroplasty in elbows with disrupted ligaments. METHODS: Eight cadaveric upper extremities were studied in an in vitro elbow simulator that employed computer-controlled actuators to govern tendon-loading. Testing was performed in stable, medial collateral ligament-deficient, and lateral collateral ligament-deficient elbows with the radial head intact, with the radial head excised, and after radial head arthroplasty. Valgus angulation and rotational kinematics were determined during passive and simulated active motion with the arm dependent. Maximum varus-valgus laxity was measured with the arm in a gravity-loaded position. RESULTS: In specimens with intact ligaments, elbow kinematics were altered and varus-valgus laxity was increased after radial head excision and both were corrected after radial head arthroplasty. In specimens with disrupted ligaments, elbow kinematics were altered after radial head excision and were similar to those observed in specimens with a native radial head after radial head arthroplasty. Varus-valgus laxity was increased after ligament disruption and was further increased after radial head excision. Varus-valgus laxity was corrected after radial head arthroplasty and ligament repair; however, it was not corrected after radial head arthroplasty without ligament repair. CONCLUSIONS: Radial head excision causes altered elbow kinematics and increased laxity. The kinematics and laxity of stable elbows after radial head arthroplasty are similar to those of elbows with a native radial head. However, radial head arthroplasty alone may be insufficient for the treatment of complex fractures that are associated with damage to the collateral ligaments as arthroplasty alone does not restore stability to elbows with ligament injuries.  相似文献   

5.
重建肘关节外翻稳定性的生物力学研究   总被引:4,自引:1,他引:3  
目的 评价肘关节桡骨头 (radial head,RH)切除、尺侧副韧带 (medial collateral ligament,MCL )损伤以及 RH假体置换、MCL重建后的外翻稳定性。 方法 新鲜成人尸体上肢标本 12侧 ,制成肘关节“骨 -韧带”标本 ,在2 N· m的外翻力矩作用下 ,分别在肘关节 0°、30°、6 0°、90°和 12 0°伸屈时 ,测量肘关节外翻松弛度 :1完整肘关节(n=12 ) ;2 MCL切断 (n=6 ) ;3RH切除 (n=6 ) ;4 MCL切断 +RH切除 (n=12 ) ;5 RH假体置换 (n=6 ) ;6 MCL重建(n=6 ) ;7RH假体置换 +MCL重建 (n=12 )。用 SPSS 10 .0统计软件包作方差分析 ,比较各组的外翻稳定性。 结果 完整肘关节的平均外翻松弛度最小 ;RH切除后 ,外翻松弛度增大 ;单纯 MCL切断 ,外翻松弛度大于单纯 RH切除 (P<0 .0 1) ;MCL切断 +RH切除 ,外翻稳定性最差 ;行 RH假体置换 ,对稳定性有改善 ;MCL重建与完整 MCL差异无统计学意义 (P>0 .0 5 ) ;RH假体置换同时重建 MCL ,效果最好。 结论  MCL是抵抗肘关节外翻应力最主要的因素 ,RH是次要因素。在重建肘关节的外翻稳定性方面 ,MCL的重建比 RH的假体置换更重要。在无条件行 RH假体置换时 ,修复MCL是较好的手术方式。  相似文献   

6.
Elbow joint dislocation was simulated in cadaveric specimens to quantify laxity induced by radial head and coronoid process lesions, either alone or in combination with collateral ligament insufficiency. The effects of lateral ligament reconstruction and radial head prosthesis replacement were also considered. Absence of the radial head and the coronoid process induced rotatory laxity of 145% and 128% (both P <.01), respectively, compared with the intact joint. When both were absent, the joints subluxated regardless of collateral ligament status. Isolated radial head prosthesis implantation prevented this subluxation, and laxity almost normalized. Lateral collateral ligament reconstruction prevented major laxity even in the absence of the radial head. Lateral collateral ligament reconstruction and radial head prosthetic replacement yielded restraint against gross instability in the maximal unstable situation (terrible triad). The lateral collateral ligament is the prime stabilizer to external rotation, and reconstruction of this alone, even with an absent radial head, is beneficial.  相似文献   

7.
The objectives of this experimental study were to investigate the effect of radial head excision and lateral collateral ligament (LCL) division on elbow joint laxity and to determine the efficacy of radial head prosthetic replacement and LCL repair. Valgus, varus, internal rotation, and external rotation of the ulna were measured during passive flexion-extension and application of a 0.75-Nm torque in 6 intact cadaveric elbows and after (1) either excision of the radial head or division of the LCL, (2) removal of both constraints, (3) isolated radial head prosthetic replacement, (4) isolated LCL repair, and (5) radial head replacement combined with LCL repair. Isolated radial head excision increased varus (mean, 4.8 degrees) and external rotatory laxity (mean, 7.1 degrees), as did isolated LCL division (mean, 14.1 degrees for varus; mean, 14.7 degrees for external rotation). After removal of both constraints, varus and external rotatory laxities were increased by 19.0 degrees and 20.1 degrees, respectively, compared with the intact specimens. Isolated radial head replacement reduced mean varus laxity to 14.6 degrees and mean external rotatory laxity to 14.8 degrees. Isolated LCL repair normalized varus laxity but resulted in a 2.9 degrees increase in external rotatory laxity. The combined procedures restored laxity completely. The radial head is a constraint to varus and external rotation in the elbow joint, functioning by maintaining tension in the LCL. Still, removal of both constraints induces severe laxity, and in this case, prosthetic replacement may substitute for the constraining capacity of the native radial head. The combination of LCL repair and radial head replacement restores laxity completely, but an isolated LCL repair performs almost as well, probably by compensating for the ligamentous tension lost from radial head excision.  相似文献   

8.
The objective of this study was to determine the effect of suture repair of type 1 coronoid fractures on elbow kinematics in ligamentously intact and medial collateral ligament (MCL)-deficient elbows. Cadaveric testing was performed in stable and MCL-deficient elbows with radial head arthroplasty and with the coronoid intact, with the coronoid fractured, and after suture repair. Ulna versus humerus angulation was measured during active motion. Varus and valgus motion pathways were measured during passive gravity-loaded flexion. With intact ligaments, there was a small increase in valgus angulation after a type 1 fracture that was not corrected with suture fixation. With MCL deficiency, there was no change in kinematics regardless of coronoid status. Type 1 coronoid fractures cause only small changes in elbow kinematics that are not corrected with suture repair. MCL repair, rather than type 1 coronoid fixation, should be considered if the elbow remains unstable after radial head repair or replacement and lateral ligament repair.  相似文献   

9.

Background

Monopolar and bipolar radial head prosthetic arthroplasties have been used successfully to treat elbow fracture-dislocation with unsalvageable radial head fractures. The relative stability of these two designs in different clinical situations is a topic of ongoing investigation.

Questions/purposes

We tested the effects of monopolar and bipolar fixed-neck prosthetic radial head implants on improvement in elbow coronal and axial plane laxity in a terrible triad biomechanical model that accounted for lateral collateral ligament integrity and the presence of a transverse coronoid fracture.

Methods

Kinematic data were collected on six fresh-frozen cadaveric upper extremities tested with passive motion throughout the flexion arc. Varus and valgus gravity stress were applied with the wrist in neutral position. A lateral collateral ligament reconstruction was simulated. We assessed instability after radial head resection and reconstruction with either a monopolar or bipolar implant in the presence of a transversely fractured (Regan and Morrey Type 2) or fixed coronoid process.

Results

With collateral ligament integrity, no difference was detected, with the numbers available, in valgus laxity between implants under valgus stress (p = 1.0). Laxity improvement with each prosthesis was higher when the coronoid was fractured (mean ± SD: monopolar: 7.4° ± 1.6°, p < 0.001; bipolar: 6.4° ± 1.6°, p = 0.003) than when it was fixed (monopolar: 4.0° ± 1.6°, p = 0.02; bipolar: 4.2° ± 1.6°, p = 0.01). With the numbers available, there was no difference in external rotation laxity between implants under valgus stress (p = 1.0). The greatest stabilizing effect of the prostheses occurred when the coronoid was fractured (monopolar: 3.3° ± 1.2°, p = 0.15; bipolar: 3.3° ± 1.2°, p = 0.17). Radial head arthroplasty offered no substantial stability under varus stress for varus or internal rotation laxity.

Conclusions

In our terrible triad cadaveric model, coronoid fixation was effective in improving varus laxity with a monopolar or bipolar prosthesis in place. Also, both types of prostheses were effective in improving valgus and external rotation laxity to the elbow, regardless of coronoid status. With collateral ligaments reconstructed, no large kinematic differences were noted between implants regardless of the varus-valgus position or whether the coronoid was fractured or fixed.

Clinical Relevance

The data from our cadaveric model support the use of either implant type in terrible triad injuries if the collateral ligaments are intact or reconstructed.  相似文献   

10.
BACKGROUND: In the presence of additional disruption of the distal radioulnar ligaments, the interosseous membrane, or the lateral- and/or medial collateral ligament, radial head fractures treated by resection will result in valgus elbow instability, proximal radial migration and/or posterolateral rotatory instability. Radial head replacement has been used to treat or prevent this. We report our experience with the Judet CRF II radial head prosthesis. PATIENTS AND METHODS: We treated 11 patients with a bipolar radial head prosthesis because of elbow instability after previous treatment for Mason-Johnston type III or IV radial head fractures. The outcome was assessed clinically using two standardized elbow function assessment scales, and radiographically after a mean follow-up of 2 years. RESULTS: Clinical outcome was either good or excellent in all patients; all elbows were stable. Radiographically, there were no signs of loosening, fracture or heterotopic ossification. 2 patients required reoperation for subluxation of the prosthesis; both were treated by reducing the size of the modular head of the prosthesis. There was erosion of the capitellum in 1 patient. INTERPRETATION: Bipolar radial head replacement can be used successfully for treatment of the sequelae of radial head fractures. The long-term outcome is, however, unknown.  相似文献   

11.
The effects of a radial head component on total elbow arthroplasty kinematics and stability were evaluated using an anatomic design unlinked total elbow prosthesis. An electromagnetic tracking device recorded motion and varus and valgus displacements under various conditions in 10 cadaveric elbows. The motion patterns of the intact elbows and the Sorbie-Questor total elbow prostheses with a radial head component were similar, as both tended to have a valgus position in extension, varus at midflexion, and more valgus toward full flexion. Under conditions of simulated muscle loading, the maximum valgus and varus laxity of the elbow prosthesis was, on average, 8.6 degrees +/- 4.0 degrees greater than normal. Without the radial head component, however, significant kinematic disturbances and instabilities were seen. The varus and valgus displacements were 13.3 degrees +/- 5.5 degrees greater than the intact elbows. One total elbow arthroplasty without a radial head dislocated during testing. Increasing the muscle loading across the elbow significantly enhanced dynamic stability of the total elbow arthroplasties, especially in the extension half of elbow motion where instability is greatest. However, this dynamic enhancement of stability was seen only in those elbows in which the radial head component had been implanted. The radial head component is an important stabilizer, particularly in extension for this prosthesis, and possibly for other unlinked total elbow prostheses. Although instability of unlinked prostheses depends on the prosthetic design, the use of a radial head replacement may be an important factor in preventing such instability. Perhaps even more importantly, a radial head component balances the load distribution across the articulation, which could decrease stress on the ulnohumeral articulation and therefore possibly reduce polyethylene wear, osteolysis, and loosening.  相似文献   

12.
Nonanatomic insertion of radial head prostheses may result in maltracking and capitellar erosion. The purpose of this study was to analyze the ability to perform anatomic radial head replacement and to study radiocapitellar prosthetic subluxation under unstable conditions. In vitro measurements were performed in 10 intact elbows and after insertion of radial head prostheses (rigid uncemented, rigid cemented, bipolar). The diameter and length of the proximal radius were approximately restored. However, prosthesis-shaft malalignment, up to 21 degrees , was observed frequently. A posterolateral rotatory stress after resection of 50% of the coronoid caused a mean radiocapitellar subluxation of more than 30% for the rigid prostheses, whereas bipolar devices self-aligned with a mean subluxation similar to intact elbows. In conclusion, it was not possible to consistently insert radial head prostheses anatomically. Marked radiocapitellar subluxation occurred for the rigid but not for the bipolar implants. Clinical trials are needed to analyze these findings.  相似文献   

13.
We studied the stabilising effect of prosthetic replacement of the radial head and repair of the medial collateral ligament (MCL) after excision of the radial head and section of the MCL in five cadaver elbows. Division of the MCL increased valgus angulation (mean 3.9 +/- 1.5 degrees) and internal rotatory laxity (mean 5.3 +/- 2.0 degrees). Subsequent excision of the radial head allowed additional valgus (mean 11.1 +/- 7.3 degrees) and internal rotatory laxity (mean 5.7 +/- 3.9 degrees). Isolated replacement of the radial head reduced valgus laxity to the level before excision of the head, while internal rotatory laxity was still greater (2.8 +/- 2.1 degrees). Isolated repair of the MCL corrected internal rotatory laxity, but a slight increase in valgus laxity remained (mean 0.7 +/- 0.6 degrees). Combined replacement of the head and repair of the MCL restored stability completely. We conclude that the radial head is a constraint secondary to the MCL for both valgus displacement and internal rotation. Isolated repair of the ligament is superior to isolated prosthetic replacement and may be sufficient to restore valgus and internal rotatory stability after excision of the radial head in MCL-deficient elbows.  相似文献   

14.
The effect of radial head fracture size on elbow kinematics and stability.   总被引:2,自引:0,他引:2  
This study determined the effect of radial head fracture size and ligament injury on elbow kinematics. Eight cadaveric upper extremities were studied in an in vitro elbow simulator. Testing was performed with ligaments intact, with the medial collateral (MCL) or lateral collateral (LCL) ligament detached, and with both the MCL and LCL detached. Thirty degree wedges were sequentially removed from the anterolateral radial head up to 120 degrees . Valgus angulation and external rotation of the ulna relative to the humerus were determined for passive motion, active motion, and pivot shift testing with the arm in a vertical (dependent) orientation. Maximum varus-valgus laxity was calculated from measurements of varus and valgus angulation with the arm in horizontal gravity-loaded positions. No effect of increasing radial head fracture size was observed on valgus angulation during passive and active motion in the dependent position. In supination, external rotation increased with increasing fracture size during passive motion with LCL deficiency and both MCL and LCL deficiency. With intact ligaments, maximum varus-valgus laxity increased with increasing radial head fracture size. With ligament disruption, elbows were grossly unstable, and no effect of increasing radial head fracture size occurred. During pivot shift testing, performed with the ligaments intact, subtle instability was noted after resection of one-third of the radial head. In this in vitro biomechanical study, small subtle effects of radial head fracture size on elbow kinematics and stability were seen in both the ligament intact and ligament deficient elbows. These data suggest that fixation of displaced radial head fractures less than or equal to one-third of the articular diameter may have some biomechanical advantages; however, clinical correlation is required.  相似文献   

15.
《Acta orthopaedica》2013,84(6):867-872
Background?In the presence of additional disruption of the distal radioulnar ligaments, the interosseous membrane, or the lateral- and/or medial collateral ligament, radial head fractures treated by resection will result in valgus elbow instability, proximal radial migration and/or posterolateral rotatory instability. Radial head replacement has been used to treat or prevent this. We report our experience with the Judet CRF II radial head prosthesis.

Patients and methods?We treated 11 patients with a bipolar radial head prosthesis because of elbow instability after previous treatment for Mason-Johnston type III or IV radial head fractures. The outcome was assessed clinically using two standardized elbow function assessment scales, and radiographically after a mean follow-up of 2 years.

Results?Clinical outcome was either good or excellent in all patients; all elbows were stable. Radiographically, there were no signs of loosening, fracture or heterotopic ossification. 2 patients required reoperation for subluxation of the prosthesis; both were treated by reducing the size of the modular head of the prosthesis. There was erosion of the capitellum in 1 patient.

Interpretation?Bipolar radial head replacement can be used successfully for treatment of the sequelae of radial head fractures. The long-term outcome is, however, unknown.

?  相似文献   

16.
Posterolateral rotatory instability is the most common type of symptomatic chronic instability of the elbow. In this condition the forearm complex rotates externally in relation to the humerus, causing posterior subluxation or dislocation of the radial head. The lateral ligament complex, radial head and coronoid process are important constraints to posterolateral rotatory instability, and their disruption is involved in the pathogenesis of this condition. The diagnosis relies on a high index of clinical suspicion, active and passive apprehension tests, and examination under anaesthesia. Surgical treatment has given consistently successful results. Open reconstruction of the lateral ligaments with a tendon graft has been the procedure of choice, with arthroscopic techniques emerging as a potential alternative.  相似文献   

17.
The motion pattern and laxity of 8 cadaveric elbows were recorded with a 3-dimensional electromagnetic tracking device before and after the Souter-Strathclyde total elbow prosthesis was implanted. The Souter-Strathclyde prosthesis replicates the valgus-varus motion pattern of the intact elbow but causes a significant internal rotation of the ulnar shaft of 8.9 degrees +/- 4.1 degrees (P < .0005) at 110 degrees of elbow flexion. One of the reasons for this unphysiological motion pattern is positioning of the humeral component in a mean of 5.4 degrees +/- 6.4 degrees of external rotation compared with the intact elbow (P = .05). This positioning is related to the design of this device. The Souter-Strathclyde elbow prosthesis has a mean maximum valgus-varus laxity of 6.5 degrees +/- 1.5 degrees compared with 4.3 degrees +/- 2.3 degrees for the intact elbow (P = .004). This implant is more constrained than previously tested devices, which may explain its relatively higher loosening rate.  相似文献   

18.
Metallic radial head arthroplasty improves valgus stability of the elbow   总被引:15,自引:0,他引:15  
The stabilizing influence of radial head arthroplasty was studied in eight medial collateral ligament deficient anatomic specimen elbows. An elbow testing apparatus, which used computer controlled pneumatic actuators to apply tendon loading, was used to simulate active elbow flexion. The motion pathways of the elbow were measured using an electromagnetic tracking device, with the forearm in supination and pronation. As a measure of stability, the maximum varus to valgus laxity over the range of elbow flexion was determined from the difference between varus and valgus gravity loaded motion pathways. After transection of the medial collateral ligament, the radial head was excised and replaced with either a silicone or one of three metallic radial head prostheses. Medial collateral ligament transection caused a significant increase in the maximum varus to valgus laxity to 18.0 degrees +/- 3.2 degrees. After radial head excision, this laxity increased to 35.6 degrees +/- 10.3 degrees. The silicone implant conferred no increase in elbow stability, with a maximum varus to valgus laxity of 32.5 degrees +/- 15.5 degrees. All three metallic implants improved the valgus stability of the medial collateral ligament deficient elbow, providing stability similar to the intact radial head. The use of silicone arthroplasty to replace the radial head in the medial collateral ligament deficient elbow must be questioned. Metallic radial head arthroplasty provides improved valgus stability, approaching that of an intact radial head.  相似文献   

19.
BACKGROUND: The lateral ulnar collateral ligament, the entire lateral collateral ligament complex, and the overlying extensor muscles have all been suggested as key stabilizers against posterolateral rotatory instability of the elbow. The purpose of this investigation was to determine whether either an intact radial collateral ligament alone or an intact lateral ulnar collateral ligament alone is sufficient to prevent posterolateral rotatory instability when the annular ligament is intact. METHODS: Sequential sectioning of the radial collateral and lateral ulnar collateral ligaments was performed in twelve fresh-frozen cadaveric upper extremities. At each stage of the sectioning protocol, a pivot shift test was performed with the arm in a vertical position. Passive elbow flexion was performed with the forearm maintained in either pronation or supination and the arm in the varus and valgus gravity-loaded orientations. An electromagnetic tracking device was used to quantify the internal-external rotation and varus-valgus angulation of the ulna with respect to the humerus. RESULTS: Compared with the intact elbow, no differences in the magnitude of internal-external rotation or maximum varus-valgus laxity of the ulna were detected with only the radial collateral or lateral ulnar collateral ligament intact (p > 0.05). However, once the entire lateral collateral ligament was transected, significant increases in internal-external rotation (p = 0.0007) and maximum varus-valgus laxity (p < 0.0001) were measured. None of the pivot shift tests had a clinically positive result until the entire lateral collateral ligament was sectioned. CONCLUSIONS: This study suggests that, when the annular ligament is intact, either the radial collateral ligament or the lateral ulnar collateral ligament can be transected without inducing posterolateral rotatory instability of the elbow.  相似文献   

20.

Background

After elbow fracture-dislocation, surgeons confront numerous treatment options in pursuing a stable joint for early motion. The relative contributions of the radial head and coronoid, in combination, to elbow stability have not been defined fully.

Questions/purposes

The purpose of this study was to evaluate the effect of an approximately 50% transverse coronoid fracture and fixation in the setting of an intact or resected radial head on coronal (varus/valgus) and axial (internal and external rotational) laxity in (1) gravity varus stress; and (2) gravity valgus stress models.

Methods

Kinematic data were collected on six fresh-frozen cadaveric upper extremities tested with passive motion throughout the flexion arc under varus and valgus gravity stress with lateral collateral ligaments reconstructed. Testing included coronoid fracture and osteosynthesis with and without a radial head.

Results

In the varus gravity stress model, fixation of the coronoid improved varus stability (fixed: 1.6° [95% confidence interval, 1.0–2.2], fractured: 5.6° [4.2–7.0], p < 0.001) and internal rotational stability (fixed: 1.8° [0.9–2.7], fractured: 5.4° [4.0–6.8], p < 0.001), but radial head fixation did not contribute to varus stability (intact head: 2.7° [1.3–4.1], resected head: 3.8° [2.3–5.3], p = 0.4) or rotational stability (intact: 2.7° [0.9–4.5], resected head: 3.9° [1.5–6.3], p = 0.4). With valgus stress, coronoid fixation improved valgus stability (fixed: 2.1° [1.0–3.1], fractured: 3.8° [1.8–5.8], p < 0.04) and external rotation stability (fixed: 0.8° [0.1–1.5], fractured: 2.1° [0.9–3.4], p < 0.04), but the radial head played a more important role in providing valgus stability (intact: 1.4° [0.8–2.0], resected head: 7.1° [3.5–10.7], p < 0.001).

Conclusions

Fixation of a 50% transverse coronoid fracture improves varus and internal rotatory laxity but is unlikely to meaningfully improve valgus or external rotation laxity. The radial head, on the other hand, is a stabilizer to resist valgus stress regardless of the status of the coronoid.

Clinical Relevance

Determination as to whether it is necessary to fix a coronoid fracture should be based on the stability of the elbow when tested with a varus load. The elbow may potentially be stable with fractures involving less than 50% of the coronoid. Under all circumstances, the radial head should be fixed or replaced to ensure valgus external rotatory stability.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号