首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.

Purpose

This study aimed at comparing the diagnostic accuracy of ultrasonography (US) and magnetic resonance imaging (MRI) for the detection of joint effusion of the knee.

Methods

For this retrospective study, approbation by the institutional review board was not required, and written informed consent from the patients was waived. One hundred and fifty-eight patients (83 men and 75 women; median age 41.2 years; age range 13–81 years) who underwent US and MRI of the knee were included in the study. The sensitivity and specificity of US with respect to MRI in the evaluation of the effusion of the knee and in each recess were compared.

Results

In evaluating joint effusion of the knee, compared with MRI, US correctly identified 78 of 96 patients with joint effusion, showing a sensitivity of 81.3 % and a specificity of 100 %, with a positive predictive value (PPV) of 100 % and a negative predictive value (NPV) of 77.5 % (p value = 0.001). Various results were obtained comparing ultrasound with MRI, regarding the various recesses.

Conclusion

US showed high specificity and sensitivity in diagnosing knee joint effusion and could be used in patients who cannot undergo MRI.

Electronic supplementary material

The online version of this article (doi:10.1007/s40477-015-0180-3) contains supplementary material, which is available to authorized users.  相似文献   

2.

Purpose

To assess the diagnostic accuracy and inter-observer variability of ultrasound (US) in recognizing signs of intra or extra-capsular rupture of silicone breast implants by using the magnetic resonance imaging (MRI) findings as the reference standard.

Methods

150 patients for a total of 300 implants underwent breast US and subsequently MR examination searching for signs of intra or extra-capsular rupture. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and diagnostic accuracy were calculated for breast US having MRI findings as the reference standard. Cohen’s kappa statistics was used in order to assess inter-observer agreement for US.

Results

170/300 (57 %) implant ruptures were detected at US (intra-capsular n = 110, extra-capsular n = 60). By comparing US findings with MR results, overall sensitivity, specificity, accuracy, PPV, and NPV of 79, 63, 70, 65, and 77 %, respectively, were found for breast US. In case of intra-capsular rupture, sensitivity, specificity, accuracy, PPV, and NPV of 63, 63, 63, 45, and 77 %, respectively, were obtained; 100 % values were found for extra-capsular rupture US diagnosis.

Conclusion

US can be used as the first examination in patients with breast implants. US intra-capsular rupture detection requires further evaluation by MRI; in case of extra-capsular rupture US diagnosis, surgical implant removal could be proposed without further investigations.  相似文献   

3.

Purpose

To evaluate the feasibility and utility of serial measuring of the optic nerve sheath diameter beyond the hyperacute and acute stage of intracerebral hemorrhage (ICH).

Methods

Four patients with extensive ICH in the left basal ganglia were followed using ultrasound (US) and cerebral CT scans.

Results

Optic nerve sheath diameter values assessed beyond the acute stage of ICH showed a high correlation (ρ = 0.84, p = 0.0022) with midline shift of the third ventricle seen on CT scans.

Conclusions

Optic nerve sonography can be useful to evaluate patients with extensive ICH beyond the acute stage and help monitoring clinical evolution in these patients, when ICP monitoring is not feasible.  相似文献   

4.

Background and purpose

Sonoelastography (SE) is a new technique that can assess differences in tissue stiffness. This study investigated the performance of SE for the differentiation of supraspinatus (SSP) tendon alterations of tendinopathy compared to magnetic resonance imaging (MRI) and conventional ultrasonography (US).

Methods

One hundred and eighteen consecutively registered patients with symptoms and MRI findings of SSP tendinopathy were assessed with US and SE. Coronal images of the SSP tendon were obtained using US and SE. Increased signal intensity on T2-weighted images in the coronal planes were graded according to the extent of the signal changes from ventral to dorsal. SE images were evaluated by reviewers using an experimentally proven color grading system.

Results

Using SE, 7.6 % of the SSP tendons were categorized as grade 0, 30.5 % as grade 1, 19.5 % as grade 2, and 42.4 % as grade 3. Evaluation of the interobserver reliability of the SE findings showed “almost perfect agreement”, with a weighted kappa coefficient of 0.83. By comparing the MRI findings with the SE findings, grades of MRI and SE had a positive correlation (r = 0.829, p = <0.001). Furthermore, grades of US and SE also had a positive correlation (r = 0.723, p = <0.001).

Conclusions

SE is valuable in the detection of the intratendinous and peritendinous alterations of the SSP tendon and has excellent interobserver reliability and excellent correlation with MRI findings and conventional ultrasonography findings.  相似文献   

5.

Purpose

Total hip arthroplasty (THA) is a widespread option for treating hip osteoarthritis. Peri-prosthetic complications after THA represent a common event influencing patient outcome and costs. The purpose of this paper is to report the use of ultrasonography (US) to detect peri-prosthetic complications in symptomatic patients who underwent THA.

Methods

We retrospectively reviewed the records of patients with THA who underwent imaging evaluation between January 2009 and December 2012 at two different institutions. We evaluated the presence/absence of superficial and/or deep peri-prosthetic collections as well as the presence/absence of a cutaneous sinus tract. For patients who underwent both MRI and US, a concordance correlation analysis between US and MR findings was performed.

Results

In the reference period, 532 symptomatic patients (mean age ± standard deviation 74 ± 12 years) underwent X-ray and MRI examinations for suspected peri-prosthetic complications. Among them, 111 (20.9 %) underwent also US. Overall, 108 patients underwent both US and MRI. US findings included 67 superficial collections, 48 subcutaneous fistulas, 74 deep peri-prosthetic collections. Twenty-four patients had solid, mass-like peri-prosthetic collections. In 11 patients, no peri-prosthetic complications were seen. MRI findings included 68 superficial collections, 49 subcutaneous fistulas, 79 deep peri-prosthetic collections. Twenty-four patients had solid, mass-like peri-prosthetic collections. In four patients, no peri-prosthetic complications were seen. Concordance analysis between US and MRI findings showed almost perfect agreement (k ≥ 0.89).

Conclusion

US is an efficient and practical imaging modality to evaluate peri-prosthetic complications in patients with THA, being almost comparable to MRI in detecting and characterizing these complications.  相似文献   

6.

Background:

Neuromuscular Electrical Stimulation is a common intervention to address muscle weakness, however presents with many limitations such as fatigue, muscle damage, and patient discomfort that may influence its effectiveness. One novel form of electrical stimulation purported to improve neuromuscular re‐education is Patterned Electrical Neuromuscular Stimulation (PENS), which is proposed to mimic muscle‐firing patterns of healthy individuals. PENS provides patterned stimulating to the agonist muscle, antagonist muscle and then agonist muscle again in an effort to replicate firing patterns.

Purpose:

The purpose of this study was to determine the effect of a single PENS treatment on knee extension torque and quadriceps activation in individuals with quadriceps inhibition.

Methods:

18 subjects (10 males and 8 females: 24.2±3.4 years, 175.3±11.8cm, 81.8±12.4kg) with a history of knee injury/pain participated in this double‐blinded randomized controlled laboratory trial. Participants demonstrated quadriceps inhibition with a central activation ratio of ≤90%. Maximal voluntary isometric contraction of the quadriceps and central activation ratio were measured before and after treatment. The treatment intervention was a 15‐minute patterned electrical stimulation applied to the quadriceps and hamstring muscles with a strong motor contraction or a sham group, who received an identical set up as the PENS group, but received a 1mA subsensory stimulation. A 2×2 (group × time) ANCOVA was used to determine differences in maximal voluntary isometric contraction and central activation ratio between groups. The maximal voluntary isometric contraction was selected as a covariate due to baseline differences.

Results:

There were no differences in change scores between pre‐ and post‐intervention for maximal voluntary isometric contraction: (PENS: 0.09±0.32Nm/kg and Sham 0.15±0.18Nm/kg, p=0.713), or central activation ratio:(PENS: ‐1.22±6.06 and Sham: 1.48±3.7, p=0.270).

Conclusions:

A single Patterned Electrical Neuromuscular Stimulation treatment did not alter quadriceps central activation ratio or maximal voluntary isometric contraction. Unlike other types of muscle stimulation, PENS did not result in a reduction of quadriceps torque.

Level of Evidence:

Level III  相似文献   

7.

Objective

The purpose of this study was to evaluate sonoelastography (SE) in the assessment of the long head of biceps tendon (LHBT) in patients with symptoms of biceps tendinitis or tendinosis and in patients without biceps lesion. The findings were compared with those obtained at clinical examination, using ultrasonography (US).

Materials and methods

36 shoulders of 34 consecutively registered patients with clinical symptoms and US findings of biceps tendinitis or tendinosis, and 114 shoulders of 98 patients without biceps lesions were assessed with SE. Transverse and longitudinal images of LHBT were obtained using SE. SE images were evaluated by reviewers using an experimentally proven color grading system.

Results

The transverse images of SE showed a mean sensitivity of 69.4 %, a mean specificity of 95.6 % and a mean accuracy of 89.3 %. Good correlation of conventional ultrasound findings was found (p < 0.001, r = 0.763). The longitudinal images of SE showed a mean sensitivity of 94.4 %, a mean specificity of 92.1 % and a mean accuracy of 92.7 %. Good correlation of conventional ultrasound findings was found (p < 0.001, r = 0.585). Inter-observer reliability of SE was in “almost perfect agreement” with a weighted kappa coefficient of 0.84.

Conclusions

SE has potential to be clinically useful in the detection of the intratendinous and peritendinous alterations of LHBT and has excellent accuracy and excellent correlation with conventional ultrasound findings.  相似文献   

8.

Objective

Sonolastography (SE) technique is one of the new functional ultrasonic imaging techniques, which was developed in the past few years and can obtain the distributions of elasticity in tissues. Using magnetic resonance imaging (MRI) as the standard of reference, the purpose of this study was to evaluate the ability of SE to assess the fatty degeneration of suprasupinatus (SSP) and to compare it to the MRI and the conventional ultrasonography (US) findings.

Materials and methods

The institutional review board approved the study, and a retrospective analysis between January 2013 and September 2013 was performed on 101 shoulders of 98 consecutive patients using MRI, US, and SE for the evaluation of shoulder lesion. Oblique sagittal images of SSP were obtained using SE. The SE images were evaluated by reviewers using an experimentally proven color grading system.

Results

When comparing SE to standard MRI findings, the mean sensitivity of SE was 95.6 %, the specificity 87.5 %, and the accuracy 91.1 %. The interobserver reliability of the SE findings was “almost perfect agreement” with a weighted kappa coefficient of 0.81. On comparing MRI with the SE findings, the grades of MRI and SE have a positive correlation (r = 0.855, P = <0.001). Furthermore, the grades of US and SE also have a positive correlation (r = 0.793, P = <0.001).

Conclusion

SE is valuable in the quantitative assessment of the severity of the fatty atrophy of the supraspinatus and has an excellent accuracy, an excellent correlation with MRI and the conventional US, and an excellent interobserver reliability.  相似文献   

9.

Objective

To evaluate the use of ultrasound for the diagnosis of knee bursitis.

Materials and methods

One-hundred and fifty-eight patients who, from May 2013 to May 2014, had an ultrasound examination of the knee and magnetic resonance imaging (MRI) of the knee during the following month were eligible for the study. The exams were reviewed by two musculoskeletal radiologists with 20 years of experience.

Results

Of these patients, 15 (7 men, 8 women) had bursitis, while 143 (76 men, 67 women) had no bursitis. In evaluating knee bursitis, US, when compared to MRI, correctly identified 13 out of 15 cases of bursitis, showing a sensitivity of 86.67 %, specificity 100 %, and K index of 0.92. Particularly in the suprapatellar bursa, ultrasound showed bursitis in 5 cases versus 7 by MRI (sensitivity of 71.4 %, specificity of 100 %, and K index of 0.82).

Conclusion

Ultrasound can be used as a valuable tool for the evaluation of bursitis of the superficial bursae in patients who cannot undergo MRI.  相似文献   

10.

Introduction

Pilonidal disease is a benign anorectal inflammatory disease that involves the subcutaneous adipose tissue overlying the sacrococcygeal region.

The aim of the work

The current study aimed to assess the value of preoperative evaluation of pilonidal disease and the exclusion of perianal sepsis using superficial parts ultrasonography and endoanal ultrasound.

Methodology

Referred 30 patients were clinically diagnosed as pilonidal disease, all were examined with superficial parts ultrasonography and if the disease was extending to the perianal region further endoanal US was performed to exclude perianal sepsis.

Results

7 patients showed subcutaneous abscesses and 23 patients showed pilonidal sinus tracts. Among patients with pilonidal sinus tracts, six tracts (26 %) seen as superficially situated, short narrow tracts with straight course, no side branches and with a blind end situated away from the anal canal wall. 2 (9 %) tracts showed vertical orientation and three tracts (13 %) were wide and deeply situated reaching the presacral fascia. 7 cases (30 %) showed branching pilonidal sinus tracts, two cases of them showed more than one external opening. 5 patients (22 %) showed abnormally long tracts seen reaching the perianal region.

Conclusion

Ultrasonography is an available, inexpensive, safe imaging modality that yields a high degree of accuracy in evaluating pilonidal disease and in exclusion of perianal sepsis.  相似文献   

11.

Aim

The aim of this study was to review our 18-year experience in the treatment of viable hydatid liver cysts (HLCs) with double percutaneous aspiration and ethanol injection (D-PAI) and to provide indications for the clinical management of HLCs.

Materials and methods

From January 1989 to December 2007, 127 patients (100 males; 13–80 years) with 184 viable HLCs (137 univesicular, 47 multivesicular; 2.8–20 cm) underwent D-PAI.

Results

Ultrasonography (US) showed complete disappearance of 125/184 (68%) cysts; in the remaining 59 cases, an inactive solid (37 cases, 20%) or liquid pattern (22 cases, 12%) was observed with volume decreases of 50–80%. The final US pattern was unmodified during the follow-up in 96.8%. Local recurrences were observed in 5 patients (3.9%): 4 patients with 8 multivesicular cysts and 1 patient with a bilocular cyst (with a solid pattern on US) that ruptured into the biliary tree 2 years after the procedure and disappeared after endoscopic sphincterectomy. The mortality rate was 0.8%, and the overall morbidity was 8.6%. The mean hospital stay was 2.9 days. The time of healing for smaller cysts (<5 cm) was shorter than that of large cysts (≥5 cm) (P < 0.001).

Conclusion

Our long-term results confirm the high effectiveness of D-PAI in the treatment of HLCs. These results suggest that multilocular cysts require closer follow-up than unilocular cysts.  相似文献   

12.

Background:

Patellofemoral pain is a common condition without a clear mechanism for its presentation. Recently significant focus has been placed on the hip and its potential role in patellofemoral pain (PFP). The majority of the research has examined hip strength and neuromuscular control. Less attention has been given to hip mobility and its potential role in subjects with PFP.

Purpose/Aim:

The purpose of this study was to compare passive hip range of motion (ROM) of hip extension and hip internal and external rotation in subjects with PFP and healthy control subjects. The hypothesis was that subjects with PFP would present with less total hip ROM and greater asymmetry than controls.

Design:

Two groups, case controlled.

Setting:

Clinical research laboratory

Participants:

30 healthy subjects without pain, radicular symptoms or history of surgery in the low back or lower extremity joints and 30 subjects with a diagnosis of PFP.

Main Outcome Measures:

Passive hip extension, hip internal rotation (IR) and hip external rotation (ER). A digital inclinometer was used for measurements.

Results:

There was a statistically significant difference (p<0.001) in hip passive extension between the control group and the PFP group bilaterally. Mean hip extension for the control group was 6.8° bilaterally. For the PFP group, the mean hip extension was −4.0° on the left and −4.3° on the right. This corresponds to a difference of means between groups of 10.8° on the left and 11.1° on the right with a standard error of 2.1°. There was no statistically significant difference (p>0.05) in either hip IR or ER ROM or total rotation between or within groups.

Conclusions:

The results of this study indicate that a significant difference in hip extension exists in subjects with PFP compared to controls. These findings suggest that passive hip extension is a variable that should be included within the clinical examination of people with PFP. It may be valuable to consider hip mobility restrictions and their potential impact on assessment of strength and planned intervention in subjects with PFP.

Level of Evidence:

2b  相似文献   

13.

Purpose

To evaluate the clinical impact of intraoperative ultrasound (IOUS) in the detection of liver metastases during the years, as compared with those of other imaging modalities.

Materials and methods

All IOUS scans performed for detection of liver metastases from 2000 to 2006 were retrospectively reviewed and compared with the results of preoperative imaging modalities: Ultrasound (US), Computed Tomography (CT), and/or Magnetic Resonance (MR). The number of cases in which IOUS and preoperative imaging studies produced discordant results, in terms of presence/absence of focal liver lesions, was calculated per year. Statistical analysis was performed using the McNemar test. A p value < 0.05 was considered statistically significant.

Results

Eighty-three IOUS scans performed in 2000–2003 were reviewed, and discordance with preoperative imaging findings was found in 19/83 (23%) cases. Of the 42 IOUS scans done during the 2004–2006 period, 10/42 (24%) showed discordance with preoperative studies. All metastases diagnosed with imaging studies were pathologically confirmed. The number of discordant cases in the two periods were not significantly different (p = 0.2).

Conclusion

IOUS is still useful in the detection of liver metastases. Its decreased use is probably due to the improved accuracy of preoperative imaging modalities.  相似文献   

14.

Background

Different limb training demands and limb preference may determine anthropometric and muscle force inter-limb asymmetries in Rhythmic Gymnastics (RG) athletes.

Purpose

The purpose of this study was to evaluate the influence of lateral preference of the lower extremity on anthropometric, range of motion, and isokinetic torque measurements of RG athletes.

Study Design

Cross sectional study

Methods

Lower limb anthropometric measurements (girth, estimated anatomical cross-sectional area), hip, knee and ankle range of motion, flexor and extensor isokinetic torques (angular velocities = 60, 180, e 240 °·s−1) and bilateral asymmetry index were evaluated in 11 international level Rhythmic Gymnastics athletes (17.9 ± 4.0 years of age; 9.1 ± 5,1 years of experience; 26.8 ± 6.0 weekly training hours).

Results

The preferred limb showed larger thigh girth and anatomical cross-sectional area, higher ankle dorsiflexor range of motion, higher hip flexor torque at 60 °·s−1 and higher plantarflexor torque at 180 °·s−1 compared to the non-preferred limb.

Conclusions

The observed differences seem to be strictly related to lateral preference and rhythmic gymnastics training.

Levels of Evidence

3  相似文献   

15.

Aim

To evaluate the usefulness of ultrasound (US) using contrast agent and elastosonography in the characterization of thyroid nodules.

Materials and methods

From November 2006 to July 2007, 23 patients with single thyroid nodules underwent B-mode US and power Doppler, US examination using contrast agent, elastosonography and fine needle aspiration cytology (FNAC). Sixteen patients underwent thyroidectomy.

Results

The 23 nodules included 14 benign and 9 malignant lesions. Analysis of time/intensity curves showed that wash-in (8.8 ± 1.3 vs 12.1 ± 2.6 s; p = 0.002, t-test) and peak enhancement (15.3 ± 4.6 vs 22.2 ± 3.9 s; p = 0.001, t-test) occurred significantly earlier in the malignant nodules than in the benign nodules. Wash-out was monophasic in 70% of benign nodules, but in none of the malignant nodules; polyphasic in 30% of benign nodules and in 100% of malignant nodules. Polyphasic wash-out showed a statistically significant association with malignancy (p = 0.0007, χ2). Polyphasic wash-out yielded a sensitivity of 100%, specificity of 71%, positive predictive value (PPV) of 69%, negative predictive value (NPV) of 100% and diagnostic accuracy of 83%. In 78% of the benign nodules (11/14) elastosonographic patterns was 1–2 (elevated elasticity); in 88% of the malignant nodules (8/9) elastosonographic patterns was 3–4 (reduced elasticity). Elastosonography yielded a sensitivity of 88%, specificity of 78%, PPV of 72%, NPV of 91% and diagnostic accuracy of 82%. Elastosonographic patterns 3–4 is associated with malignancy (p = 0.001, χ2).

Conclusion

US using contrast agent and elastosonography can be a useful diagnostic tool in the evaluation of single thyroid nodules, particularly when FNAC result is non-diagnostic or suggests a follicular lesion, and in nodules <1 cm.  相似文献   

16.

Background

An inadequate level of flexibility of the adductor muscles is one of the most critical risk factors for chronic groin pain and strains. However, measurement methods of adductor muscle flexibility are not well defined.

Purpose

To determine the inter‐session reliability of the biarticular and monoarticular adductor muscle flexibility measures obtained from passive hip abduction with the knee flexed over the edge of the plinth test (PHA) and the passive hip abduction test at 90° of hip flexion (PHA90°).

Study design

Clinical Measurement Reliability study.

Methods

Fifty healthy recreational athletes participated in this study. All participants performed the PHA and PHA90° on four different occasions, with a two‐week interval between testing sessions. Reliability was examined through the change in the mean between consecutive pairs of testing sessions (ChM), standard error of measurement expressed in absolute values (SEM) and as a percentage of the mean score (%SEM), minimal detectable change at 95% confidence interval (MDC95), and intraclass correlation coefficients (ICC2,k).

Results

The findings showed negligible or trivial ChM values for the two adductor flexibility measures analyzed (<2°). Furthermore, the SEM and MDC95 were 2.1° and 5.9° and 2.2° and 6.2° for the measures obtained from the PHA and PHA90°, respectively, with %SEM scores lower than 5% and ICC scores higher than 0.90.

Conclusion

The findings from this study suggest that the adductor muscle flexibility measures analyzed have good to excellent inter‐session reliability in recreational athletes. Thus, clinicians can be 95% confident that an observed change between two measures larger than 5.9° and 6.2° for the flexibility measures obtained from the PHA and PHA90°, respectively, would indicate a real change in muscle flexibility.

Level of evidence

2  相似文献   

17.

Objectives

Specifically we aim to demonstrate that the results of our earlier safety data hold true in this much larger multi-national and multi-ethnical population.

Background

We sought to re-evaluate the frequency, manifestations, and severity of acute adverse reactions associated with administration of several gadolinium- based contrast agents during routine CMR on a European level.

Methods

Multi-centre, multi-national, and multi-ethnical registry with consecutive enrolment of patients in 57 European centres.

Results

During the current observation 37788 doses of Gadolinium based contrast agent were administered to 37788 patients. The mean dose was 24.7 ml (range 5–80 ml), which is equivalent to 0.123 mmol/kg (range 0.01 - 0.3 mmol/kg). Forty-five acute adverse reactions due to contrast administration occurred (0.12 %). Most reactions were classified as mild (43 of 45) according to the American College of Radiology definition. The most frequent complaints following contrast administration were rashes and hives (15 of 45), followed by nausea (10 of 45) and flushes (10 of 45). The event rate ranged from 0.05 % (linear non-ionic agent gadodiamide) to 0.42 % (linear ionic agent gadobenate dimeglumine). Interestingly, we also found different event rates between the three main indications for CMR ranging from 0.05 % (risk stratification in suspected CAD) to 0.22 % (viability in known CAD).

Conclusions

The current data indicate that the results of the earlier safety data hold true in this much larger multi-national and multi-ethnical population. Thus, the “off-label” use of Gadolinium based contrast in cardiovascular MR should be regarded as safe concerning the frequency, manifestation and severity of acute events.  相似文献   

18.

Introduction

Obesity confers a survival advantage in the critically ill and in patients undergoing cardiac surgery. We explored whether an obesogenic high fat diet could confer protection against post cardiopulmonary bypass (CPB) acute kidney injury (AKI) in a swine model.

Methods

In this study, 28 anaesthetised adult female Landrace White swine (55 to 70 kg) were allocated into a 4 group design to either 2.5 hours of CPB or Sham operation with or without pre-procedural high fat (HF) feeding containing 15% lard, 1.5% cholesterol and 1% cholic acid for 12-weeks (Groups: Sham, CPB, CPB + HF and Sham + HF). Our primary endpoint was creatinine clearance measured at 1.5 and 24 hours post intervention. This is a validated index of the glomerular filtration rate (GFR) in swine and an endpoint used in our clinical studies. Secondary endpoints included measures of systemic and renal inflammation, endothelial homeostasis, tubular injury and dysfunction, and inflammatory cell signalling. Differences between groups were calculated using analysis of variance with adjustment for baseline differences for repeated measures.

Results

CPB in pigs fed a normal chow diet resulted in AKI. This was characterised by reductions in GFR sustained for up to 24 hours post injury relative to Sham operated pigs fed a normal diet; mean difference 50.2 ml/min (95% CI 5.9 to 94.4). Post CPB AKI was also characterised by renal inflammation, parallel activation of both pro-inflammatory (NF-kB, iNOS) and pro-survival pathways (pAkt, p70s6k, HIF-1α) and apoptosis. Pigs fed a 12-week high fat diet developed obesity and hyperlipidaemia. This was associated with increased redox sensitive pro-inflammatory and anti-apoptotic signalling, and tubular epithelial cell proliferation. High fat feeding also protected swine against post CPB AKI; mean difference in creatinine clearance CPB - CPB + HF −65.3 ml/min (95% CI −106.9 to −23.7), by preserving endothelial homeostasis and function, and preventing the reductions in GFR, loss of ATP and tubular apoptosis that characterise the extension phase of AKI in swine at 24 hours post injury. Reno-protection was not attributed to pAkt signaling.

Conclusions

A high fat diet promoted obesity and renal inflammation and prevented post CPB AKI in swine. This study provides insights into the obesity paradox and the failure of anti-inflammatory interventions to improve clinical outcomes in patients at risk of post cardiac surgery AKI.  相似文献   

19.

Introduction

Juvenile idiopathic arthritis (JIA) may cause damage to the temporomandibular joint (TMJ). In oligoarticular forms of JIA, TMJ involvement is often asymptomatic and consequently overlooked. The aim of this study was to evaluate the presence of TMJ joint effusion (JE) by ultrasonography (US) in patients with early arthritis.

Materials and methods

We examined 68 children (57 girls, 11 boys, age range 9.1–16.0 years, mean age 11.0 years) recently diagnosed with JIA. None had received any specific treatment for inflammation. Symptomatic TMJ involvement was diagnosed when one or more of the following were present: 1) recurrent pain (spontaneous or on movement of the jaw); 2) crepitation; 3) feeling of stiffness or fatigue of the jaw; 4) intermittent locking. US of the TMJ was performed in static and dynamic phases with a General Electric LOGIQ7 scanner and a linear transducer (8.5 MHz) positioned along the axis of the mandibular ramus. JE was diagnosed when the joint capsule was ≥1.5 mm thick.

Results

Forty-six out (68%) of 68 children had US evidence of TMJ effusions (bilateral in 16 [35%] cases), but only 2/46 were symptomatic.

Conclusions

These data suggest that children with early stage oligoarticular JIA children are likely to have inflammation of the TMJs even in the absence of symptoms. US is a simple-to-use, noninvasive, radiation-free tool that can provide useful information in the assessment and follow-up of TMJ involvement in children and young adults with JIA.  相似文献   

20.

Background

Increased left ventricular (LV) torsion has been observed in patients with manifest familial hypertrophic cardiomyopathy (HCM), and is thought to be caused by subendocardial dysfunction. We hypothesize that increased LV torsion is already present in healthy mutation carriers with normal wall thickness.

Methods

Seventeen carriers with an LV wall thickness <10 mm, and seventeen age and gender matched controls had cardiovascular magnetic resonance (CMR) cine imaging and tissue tagging. LV volumes and mass were calculated from the cine images. LV torsion, torsion rate, endocardial circumferential strain and torsion-to-endocardial-circumferential-shortening (TECS) ratio, which reflects the transmural distribution in contractile function, were determined using tissue tagging.

Results

LV volumes, mass and circumferential strain were comparable between groups, whereas LV ejection fraction, torsion and TECS-ratio were increased in carriers compared to controls (63 ± 3% vs. 60 ± 3%, p = 0.04, 10.1 ± 2.5° vs. 7.7 ± 1.2°, p = 0.001, and 0.52 ± 0.14°/% vs. 0.42 ± 0.10°/%, p = 0.02, respectively).

Conclusions

Carriers with normal wall thickness display increased LV torsion and TECS-ratio with respect to controls, which might be due to subendocardial myocardial dysfunction. As similar abnormalities are observed in patients with manifest HCM, the changes in healthy carriers may be target for clinical intervention to delay or prevent the onset of hypertrophy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号