首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
With the advent of transcatheter aortic valve replacement (TAVR), appropriately selected intermediate-, high-, and extreme-risk patients with severe aortic stenosis (AS) are now offered a less invasive option compared to conventional surgery. In contemporary practice, TAVR is performed predominantly via a transfemoral arterial approach, whereby a transcatheter heart valve (THV) is delivered in a retrograde fashion through the iliofemoral arterial system and thoraco-abdominal aorta, into the native aortic valve annulus. While the majority of patients possess suitable anatomy for transfemoral arterial access, there is a subset of patients with extensive peripheral vascular disease that precludes this traditional approach to TAVR. Fortunately, innovation in the field of structural heart disease has led to the refinement of alternative access options for THV delivery. Selection of the most appropriate route of therapy mandates a careful consideration of multiple factors, including patient anatomy, technical feasibility, and equipment specifications. Furthermore, understanding the risks conferred by each access site for valve delivery—notably stroke, vascular injury, and major bleeding—is of paramount importance when selecting the approach that will best optimize the outcome for an individual. In this review, we provide a comprehensive summary of alternative approaches to transfemoral arterial TAVR as well as the available outcome data supporting each of these various techniques.  相似文献   

2.
BackgroundProspective bicuspid low-risk transcatheter aortic valve replacement (TAVR) registries' data demonstrated encouraging short-term results. Detailed data on transcatheter heart valve (THV) geometry after deployment using contemporary devices are lacking. This study sought to examine valve geometry after TAVR in patients with bicuspid aortic stenosis (AS).MethodsThe study population was patients from the LRT (Low Risk TAVR) trial who underwent TAVR using the SAPIEN 3 THV for bicuspid and tricuspid AS. THV geometry measured on 30-day computed tomography (CT) included valve height, angle, depth, and eccentricity. Additionally, THV hemodynamics and outcomes post-TAVR were compared among patients with bicuspid and tricuspid AS.ResultsA total of 107 patients from the LRT trial using the SAPIEN 3 THV were included in our analysis. On 30-day CT, the valve height ratio (1.07 vs. 1.07; p = 0.348), depths (right [5.6 mm vs. 6.2 mm; p = 0.223], left [5.3 mm vs. 4.4 mm; p = 0.082] and non [4.8 mm vs. 4.5 mm; p = 0.589] coronary cusps), eccentricities (1.08 vs. 1.07; p = 0.9550), and angles (except the right [3.9 degrees vs. 6.3 degrees; p = 0.003] and left [3.6 degrees vs. 6.0 degrees; p = 0.007]) were similar between bicuspid and tricuspid patients. Hemodynamics, stroke, and mortality were similar at 1 year.ConclusionDespite challenging bicuspid anatomy of the aortic valve, our comprehensive CT analysis supports similar THV geometry between patients with bicuspid and tricuspid AS undergoing TAVR using the SAPIEN 3 THV in low-risk patients. This translated to excellent short-term clinical outcomes and THV hemodynamics in both aortic valve morphologies.Trial registryNCT02628899, https://clinicaltrials.gov/ct2/show/NCT02628899.  相似文献   

3.
ObjectivesThe aim of this study was to prospectively evaluate the clinical use of patient-specific computer simulation of transcatheter aortic valve replacement (TAVR) in bicuspid aortic valve (BAV) morphology.BackgroundPatient-specific computer simulation of TAVR in BAV may predict important clinical outcomes, such as paravalvular regurgitation and conduction disturbance.MethodsBetween May 2018 and April 2019, all patients who were referred for TAVR who had BAV identified on work-up cardiac multidetector computed tomographic imaging prospectively underwent patient-specific computer simulation with a self-expanding transcatheter heart valve (THV) using TAVIguide technology.ResultsNine patients were included in the study. Sievers classification was type 0 in 2 patients and type 1 in 7 patients. The simulations altered the treatment strategy in 8 patients (89%). The simulations suggested moderate to severe paravalvular regurgitation in 3 patients, who were referred for consideration of surgery. The remaining 6 patients underwent TAVR with a self-expanding THV. In 5 of these patients (83%), THV size and/or implantation depth was altered to minimize paravalvular regurgitation and/or conduction disturbance. In 1 patient, simulations suggested significant conduction disturbance after TAVR, and a permanent pacemaker was implanted before the procedure. Following treatment, all 9 patients had no to mild paravalvular regurgitation. The patient who had a pre-procedure permanent pacemaker implanted became pacing dependent, with underlying third-degree atrioventricular block.ConclusionsPatient-specific computer simulation of TAVR in BAV can be used to identify those patients where TAVR may be associated with unfavorable clinical outcomes. Patient-specific computer simulation may be useful to guide THV sizing and positioning for potential favorable clinical outcomes.  相似文献   

4.
ObjectivesThe aim of this study was to evaluate the feasibility of coronary access and aortic valve reintervention in low-risk patients undergoing transcatheter aortic valve replacement (TAVR) with a balloon-expandable transcatheter heart valve (THV).BackgroundYounger, low-risk TAVR patients are more likely than older, higher risk patients to require coronary angiography, percutaneous coronary intervention, or aortic valve reintervention, but their THVs may impede coronary access and cause coronary obstruction during TAVR-in-TAVR.MethodsThe LRT (Low Risk TAVR) trial (NCT02628899) enrolled 200 subjects with symptomatic severe aortic stenosis to undergo TAVR using commercially available THVs. Subjects who received balloon-expandable THVs and who had 30-day cardiac computed tomographic scans were included in this study. In a subgroup, the feasibility of intentional THV crimping on the delivery catheter to pre-determine commissural alignment was tested.ResultsIn the LRT trial, 168 subjects received balloon-expandable THVs and had 30-day cardiac computed tomographic scans, of which 137 were of adequate image quality for analysis. The most challenging anatomy for coronary access (THV frame above and commissural suture post in front of a coronary ostium) was observed in 9% to 13% of subjects. Intentional THV crimping did not appear to meaningfully affect commissural alignment. The THV frame extended above the sinotubular junction in 21% of subjects, and in 13%, the distance between the THV and the sinotubular junction was <2 mm, signifying that TAVR-in-TAVR may not be feasible without causing coronary obstruction.ConclusionsTAVR may present challenges to future coronary access and aortic valve reintervention in a substantial number of low-risk patients.  相似文献   

5.
ObjectivesEvaluation of 30-day outcomes after transcatheter aortic valve replacement (TAVR) with the novel balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV) (Edwards Lifesciences, Irvine, California) emphasizing the updated Valve Academic Research Consortium (VARC-2) criteria.BackgroundPreliminary data on clinical performance with the S3 THV are promising. However, information regarding 30-day outcome is limited.MethodsA total of 250 consecutive patients undergoing transfemoral TAVR with the S3 THV at our center were enrolled, and outcomes according to VARC-2 criteria were analyzed at 30 days.ResultsThe mean age was 81.0 ± 6.2 years, median logistic EuroSCORE (European System for Cardiac Operative Risk Evaluation) and Society of Thoracic Surgeons score were 12.1% and 4.4%, respectively. VARC-2–defined device success was achieved in 244 patients (97.6%); moderate paravalvular leakage developed in 5 patients (2.0%). One patient (0.4%) died of a noncardiac cause and 8 patients (3.2%) had a stroke. Life-threatening bleeding and major vascular complications occurred in 12 (4.8%) and 9 (3.6%) of the patients, respectively. From discharge to 30 days, 5 patients (2.0%) were hospitalized due to valve-related symptoms or worsening of heart failure. The VARC-2 composite early safety endpoint was observed in 25 patients (10.0%). Permanent pacemaker implantation rate at 30 days was 15.2%. Myocardial infarction, coronary obstruction requiring intervention, valve-related dysfunction, and endocarditis were not observed.ConclusionsWe found very good 30-day results using the novel S3 THV with a low rate of clinical events according to VARC-2 criteria. The S3 THV is associated with high procedural success and favorable early safety profile. The need for pacemaker implantations appears to be more frequent than with its predecessor.  相似文献   

6.
BackgroundThe randomized SOLVE-TAVI (compariSon of secOnd-generation seLf-expandable vs. balloon-expandable Valves and gEneral vs. local anesthesia in Transcatheter Aortic Valve Implantation) trial compared newer-generation self-expanding valves (SEV) and balloon-expandable valves (BEV) as well as local anesthesia with conscious sedation (CS) and general anesthesia (GA) in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). Both strategies showed similar outcomes at 30 days.ObjectivesThe purpose of this study was to compare clinical outcomes during 1-year follow-up in the randomized SOLVE-TAVI trial.MethodsUsing a 2 × 2 factorial design 447 intermediate- to high-risk patients with severe, symptomatic aortic stenosis were randomly assigned to transfemoral TAVR using either the SEV (Evolut R, Medtronic Inc., Minneapolis, Minnesota) or the BEV (Sapien 3, Edwards Lifesciences, Irvine, California) as well as CS or GA at 7 sites.ResultsIn the valve-comparison strategy, rates of the combined endpoint of all-cause mortality, stroke, moderate or severe paravalvular leakage, and permanent pacemaker implantation were similar between the BEV and SEV group (n = 84, 38.3% vs. n = 87, 40.4%; hazard ratio: 0.94; 95% confidence interval: 0.70 to 1.26; p = 0.66) at 1 year. Regarding the anesthesia comparison, the combined endpoint of all-cause mortality, stroke, myocardial infarction, and acute kidney injury occurred with similar rates in the GA and CS groups (n = 61, 25.7% vs. n = 54, 23.8%; hazard ratio: 1.09; 95% confidence interval: 0.76 to 1.57; p = 0.63).ConclusionsIn intermediate- to high-risk patients undergoing transfemoral TAVR, newer-generation SEV and BEV as well as CS and GA showed similar clinical outcomes at 1 year using a combined clinical endpoint. (SecOnd-generation seLf-expandable Versus Balloon-expandable Valves and gEneral Versus Local Anesthesia in TAVI [SOLVE-TAVI]; NCT02737150)  相似文献   

7.
ObjectivesThe authors sought to investigate whether a patient-specific implantation technique during transcatheter aortic valve replacement (TAVR) can result in a safe and reproducible neo-commissural alignment of self-expanding transcatheter heart valves (THVs).BackgroundTo date, little attention has been paid to neo-commissural alignment during TAVR.MethodsA fluoroscopy-based, patient- and valve-specific TAVR implantation technique was applied in 60 patients treated with 3 different self-expanding THV platforms (Evolut R/PRO, Medtronic; ACURATE neo2, Boston Scientific; and Portico, Abbott—20 patients in each group). Post-TAVR cardiac computed tomography was used to assess THV neo-commissural alignment.ResultsConsidering all 60 patients, ≤mild commissural misalignment (CMA <30°) was obtained in 53 patients (88%) using this modified TAVR implantation technique—in 36 patients (60%), optimal commissural alignment (<15°) was obtained. In 2 patients, cardiac computed tomography revealed severe CMA (>45°) with overlap between the coronary ostia and THV commissures. Using the ACURATE neo2 platform, operators succeeded in avoiding ≥moderate CMA in all 20 cases. When analyzing those cases in which the optimal amount of THV rotation could be assessed and applied before THV expansion (n = 52; 87%), the success rate of TAVR with ≤mild CMA was 98%. No procedure- or valve-related complications occurred in this study cohort.ConclusionsA patient-specific TAVR implantation technique aiming to obtain neo-commissural alignment is feasible and safe, and aides to prevent THV implantations with overlap between the coronary ostia and THV commissures. Optimized TAVR devices and design may further improve the success rate of TAVR with neo-commissural alignment.  相似文献   

8.
BackgroundBefore its voluntary recall, the mechanically expandable LOTUS Edge transcatheter heart valve (THV) offered a number of unique features, notably sealing against paravalvular leak (PVL) and the ability to be fully deployed, re-captured, and re-deployed.MethodsWe performed a detailed review of all patients at our institution who underwent transcatheter aortic valve replacement (TAVR) using the LOTUS Edge THV from 2019 to 2020. We describe procedural and in-hospital outcomes.ResultsIn brief, 59 patients underwent TAVR using the LOTUS Edge, of whom 18 were high-risk (most of whom had moderate or severe left ventricular outflow tract [LVOT] calcium), 36 were intermediate-risk enrolled in the REPRISE IV trial (one of whom had a bicuspid valve), and 5 were low-risk bicuspid patients enrolled in the LRT trial. Conduction disturbances were common (new left bundle branch block in 64.4%), with high rates of new permanent pacemaker (PPM) implantation across all risk groups (16.9%). Overall, stroke occurred in 11.9% of patients, and in 3/5 low-risk bicuspid patients, but occurred less frequently in patients with cerebral embolic protection.ConclusionsIn our experience, in patients with heavy LVOT calcium burden and/or bicuspid valves, the LOTUS Edge THV offered excellent seal against PVL. However, the high rates of periprocedural stroke and new PPM implantation were a concern.  相似文献   

9.
Paravalvular aortic insufficiency (AI) is observed in the majority of patients undergoing transcatheter aortic valve replacement (TAVR). While paravalvular AI is most commonly modest following TAVR, moderate or severe AI was seen in 10.5% and 6.8% of the PARTNER inoperable and high‐risk cohorts at 1 year and has been reportedly associated with dyspnea and diminished survival. We report two cases of transcatheter heart valve (THV) associated paravalvular defects closed using catheter delivered devices. Both patients derived hemodynamic and symptomatic improvement from device closure. Additional research is warranted to define the adverse consequences of THV associated AI, indications for treatment, and risks associated with device closure of these defects. © 2012 Wiley Periodicals, Inc.  相似文献   

10.
IntroductionTranscatheter aortic valve replacement (TAVR) increases worldwide, and indications expand from high-risk aortic stenosis patients to low-risk aortic stenosis. Studies have shown that minimalistic TAVR done under conscious sedation is safe and effective. We report single-operator, the single-center outcome of 105 minimalist transfemoral, conscious sedation TAVR patients, analyzed retrospectively.MethodsAll patients underwent TAVR in cardiac catheterization lab via percutaneous transfemoral, conscious sedation approach. A dedicated cardiac anesthetist team delivered the conscious sedation with a standard protocol described in the main text. The outcomes were analyzed as per VARC-2 criteria and compared with the latest low-risk TAVR trials.ResultsA total of 105 patients underwent transcatheter aortic valve replacement between July 2016 to February 2020. The mean age of the population was 73 years, and the mean STS score was 3.99 ± 2.59. All patients underwent a percutaneous transfemoral approach. Self-expanding valve was used in 40% of cases and balloon-expandable valve in 60% (Sapien3? in 31% and MyVal? in 29%) of cases. One patient required conversion to surgical aortic valve replacement. The success rate was 99 percent. The outcomes were: all-cause mortality: 0.9%, stroke rate 1.9%, New pacemaker rate 5.7%, 87.6% had no paravalvular leak. The mild and moderate paravalvular leak was seen in 2.8% and 1.9%, respectively. The mean gradient decreased from 47.5 mmHg to 9 mmHg. The average ICU stay was 26.4 h, and the average hospital stay was 5.4 days. Our outcomes are comparable with the latest published low-risk trial.ConclusionMinimalist, conscious sedation, transfemoral transcatheter aortic valve replacement when done following a standard protocol is safe and effective.  相似文献   

11.
ObjectivesThe purpose of this study was to prospectively evaluate the safety and clinical performance of the CoreValve Evolut R transcatheter aortic valve replacement (TAVR) system (Medtronic, Inc., Minneapolis, Minnesota) in a single-arm, multicenter pivotal study in high- or extreme-risk patients with symptomatic aortic valve stenosis.BackgroundAlthough outcomes following TAVR are improving, challenges still exist. The repositionable 14-F equivalent CoreValve Evolut R TAVR system was developed to mitigate some of these challenges.MethodsSuitable patients (n = 60) underwent TAVR with a 26- or 29-mm Evolut R valve. Primary safety endpoints were mortality and stroke at 30 days. Primary clinical performance endpoints were device success per the VARC-2 (Valve Academic Research Consortium-2) and the percent of patients with mild or less aortic regurgitation 24 h to 7 days post-procedure.ResultsPatients (66.7% female; mean age 82.8 ± 6.1 years; Society of Thoracic Surgeons Score 7.0 ± 3.7%) underwent TAVR via the transfemoral route in 98.3%, using a 29-mm valve in 68.3% of patients. All attempts at repositioning were successful. No death or stroke was observed up to 30 days. The VARC-2 overall device success rate was 78.6%. Paravalvular regurgitation post TAVR was mild or less in 96.6%, moderate in 3.4%, and severe in 0% at 30 days. Major vascular complications occurred in 8.3%, and permanent pacemaker implantation was required in 11.7% of patients.ConclusionsThe repositionable 14-F equivalent Evolut R TAVR system is safe and effective at treating high-risk symptomatic aortic stenosis patients. Repositioning was successful when required in all patients, with low rates of moderate or severe paravalvular aortic regurgitation and low permanent pacemaker implantation. (The Medtronic CoreValve™ Evolut R™ CE Mark Clinical Study; NCT01876420)  相似文献   

12.
ObjectivesThis study sought to evaluate clinical outcomes and transcatheter heart valve hemodynamics at 1 year after transcatheter aortic valve replacement (TAVR) in low-risk patients.BackgroundEarly results from the LRT (Low Risk TAVR) trial demonstrated that TAVR is safe in patients with symptomatic severe aortic stenosis who are at low risk for surgical valve replacement.MethodsThe LRT trial was an investigator-initiated, prospective, multicenter study and was the first Food and Drug Administration–approved Investigational Device Exemption trial to evaluate feasibility of TAVR in low-risk patients. The primary endpoint was all-cause mortality at 30 days. Secondary endpoints included clinical outcomes and valve hemodynamics at 1 year.ResultsThe LRT trial enrolled 200 low-risk patients with symptomatic severe AS to undergo TAVR at 11 centers. Mean age was 73.6 years and 61.5% were men. At 30 days, there was zero mortality, zero disabling stroke, and low permanent pacemaker implantation rate (5.0%). At 1-year follow-up, mortality was 3.0%, stroke rate was 2.1%, and permanent pacemaker implantation rate was 7.3%. Two (1.0%) subjects underwent surgical reintervention for endocarditis. Of the 14% of TAVR subjects who had evidence of hypoattenuated leaflet thickening at 30 days, there was no impact on valve hemodynamics at 1 year, but the stroke rate was numerically higher (3.8% vs. 1.9%; p = 0.53).ConclusionsTAVR in low-risk patients with symptomatic severe aortic stenosis appears to be safe at 1 year. Hypoattenuated leaflet thickening, observed in a minority of TAVR patients at 30 days, did not have an impact on valve hemodynamics in the longer term.  相似文献   

13.
Aortic stenosis (AS), 1 of the most common valve diseases in developed countries, carries a poor prognosis if left untreated. Transcatheter aortic valve replacement (TAVR) has become the standard of care for high-risk and inoperable patients with severe aortic stenosis (AS). Women represent a significant proportion of patients with severe AS and demonstrate specific clinical, anatomic, and pathophysiological features that are evident both before and after valve replacement. In this review, we discuss these features as well as the outcomes of women undergoing TAVR for AS.  相似文献   

14.
ObjectivesThe aim of this study was to evaluate clinical outcomes and transcatheter heart valve hemodynamic parameters after transcatheter aortic valve replacement (TAVR) in low-risk patients with bicuspid aortic stenosis (AS).BackgroundTAVR is approved for low-risk patients in the United States. However, patients with bicuspid AS were excluded from the randomized cohorts of the pivotal low-risk trials.MethodsThe LRT (Low Risk TAVR) trial was an investigator-initiated, prospective, multicenter study and was the first and only U.S. Food and Drug Administration–approved investigational device exemption trial to evaluate the feasibility of TAVR with either balloon-expandable or self-expanding valves in low-risk patients with bicuspid AS. The primary endpoint was all-cause mortality at 30 days. Baseline and follow-up echocardiography and computed tomography to detect leaflet thickening were analyzed in an independent core laboratory.ResultsSixty-one low-risk patients with symptomatic, severe AS and bicuspid aortic valves (78.3% Sievers type 1 morphology) underwent TAVR at 6 centers from 2016 to 2019. The mean age was 68.6 years, and 42.6% were men. At 30 days, there was zero mortality and no disabling strokes. The rate of new permanent pacemaker implantation was 13.1%; just 1 patient had a moderate paravalvular leak at 30 days. Hypoattenuated leaflet thickening was observed in 10% of patients at 30 days.ConclusionsTAVR appears to be safe in patients with bicuspid AS, with short length of hospital stay, zero mortality, and no disabling strokes at 30 days. Subclinical leaflet thrombosis was observed in a minority of patients at 30 days but did not appear to be associated with clinical events.  相似文献   

15.
Transcatheter aortic valve replacement (TAVR) via the transfemoral (TF), transapical (TA), or even the transaortic (TAO) approach in high‐risk or inoperable patients is quickly becoming a safe and effective modality for the treatment of symptomatic severe aortic stenosis (AS). However, in this selected group of patients, those with anatomical or physiologic constraints preventing TF, TA, and conventional TAO TAVR, alternative sites of access must be explored. Here, we report a successful TAVR in an inoperable patient with severe AS using a distal abdominal TAO approach via a synthetic graft‐conduit. © 2013 Wiley Periodicals, Inc.  相似文献   

16.
BackgroundPatients with rheumatic aortic stenosis (AS) were excluded from transcatheter aortic valve replacement (TAVR) trials.ObjectivesThe authors sought to examine outcomes with TAVR versus surgical aortic valve replacement (SAVR) in patients with rheumatic AS, and versus TAVR in nonrheumatic AS.MethodsThe authors identified Medicare beneficiaries who underwent TAVR or SAVR from October 2015 to December 2017, and then identified patients with rheumatic AS using prior validated International Classification of Diseases, Version 10 codes. Overlap propensity score weighting analysis was used to adjust for measured confounders. The primary study outcome was all-cause mortality. Multiple secondary outcomes were also examined.ResultsThe final study cohort included 1,159 patients with rheumatic AS who underwent aortic valve replacement (SAVR, n = 554; TAVR, n = 605), and 88,554 patients with nonrheumatic AS who underwent TAVR. Patients in the SAVR group were younger and with lower prevalence of most comorbidities and frailty scores. After median follow-up of 19 months (interquartile range: 13 to 26 months), there was no difference in all-cause mortality with TAVR versus SAVR (11.2 vs. 7.0 per 100 person-year; adjusted hazard ratio: 1.53; 95% confidence interval: 0.84 to 2.79; p = 0.2). Compared with TAVR in nonrheumatic AS, TAVR for rheumatic AS was associated with similar mortality (15.2 vs. 17.7 deaths per 100 person-years (adjusted hazard ratio: 0.87; 95% confidence interval: 0.68 to 1.09; p = 0.2) after median follow-up of 17 months (interquartile range: 11 to 24 months). None of the rheumatic TAVR patients, <11 SAVR patients, and 242 nonrheumatic TAVR patients underwent repeat aortic valve replacement (124 redo-TAVR and 118 SAVR) at follow-up.ConclusionsCompared with SAVR, TAVR could represent a viable and possibly durable option for patients with rheumatic AS.  相似文献   

17.
ObjectivesThe aim of this study was to compare outcomes after transcatheter aortic valve replacement (TAVR) in patients with pure aortic stenosis (AS) (i.e., no or trivial associated aortic regurgitation [AR]) with those in patients with AS and mild or more severe AR (i.e., mixed aortic valve disease [MAVD]).BackgroundTAVR is indicated in treating patients with severe AS. Limited data exist regarding the outcomes of TAVR in patients with MAVD.MethodsA total of 1,133 patients who underwent TAVR between January 2014 and December 2017 were included. The primary outcome was all-cause mortality. The comparison was adjusted to account for post-TAVR AR development in both groups. The secondary outcomes included composite endpoints of early safety and clinical efficacy as specified in the Valve Academic Research Consortium-2 criteria. Variables were compared using Mann-Whitney, chi-square, and Fisher exact tests, while Kaplan-Meier analyses were used to compare survival.ResultsA total of 688 patients (61%) had MAVD (median age 83 years , 43% women). Among these, 17% developed mild, 2% moderate, and <1% severe post-TAVR AR. Overall, patients with MAVD had better survival compared with patients with pure AS (p = 0.03). Among patients who developed post-TAVR AR, those in the MAVD group had better survival (p = 0.04). In contrast, in patients who did not develop post-TAVR AR, pre-TAVR AR did not improve survival (p = 0.11).ConclusionsPatients with MAVD who underwent TAVR had better survival compared with patients with pure AS. This is explained by the better survival of patients with MAVD who developed post-TAVR AR, likely due to left ventricular adaptation to AR.  相似文献   

18.
Severe descending thoracic and abdominal aortic pathology can deter consideration of transfemoral (TF) access for transcatheter aortic valve replacement (TAVR) in adults with severe symptomatic aortic stenosis (AS) and may lead to utilization of alternative access sites. We report a case of an 88-year-old frail woman with severe symptomatic AS referred for TAVR with demonstration of a large thrombus in the descending thoracic aorta immediately distal to the left subclavian artery. Given concerns of thrombus embolization with femoral advancement of the transcatheter valve, coverage with a thoracic aortic endograft was planned immediately prior to the TAVR.  相似文献   

19.
ObjectivesThis study sought to better understand out-of-hospital 30-day mortality following transfemoral transcatheter aortic valve replacement (TAVR) and identify factors associated with poor outcomes.BackgroundDespite improvements in outcomes with TAVR for severe aortic stenosis, out-of-hospital 30-day mortality has not been evaluated.MethodsThis study examined patients in the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry undergoing TAVR for severe aortic stenosis from January 2015 to March 2018. Primary and secondary endpoints were 30-day out-of-hospital all-cause mortality and out-of-hospital cardiovascular mortality, respectively. Logistic regression models were used to assess association between pre-specified factors and endpoints.ResultsA total of 106,749 patients underwent TAVR and were eligible for analysis. Transfemoral TAVR was performed in 92.3% of patients. A total of 2,137 (2.2%) transfemoral patients died within 30 days of the procedure, and 623 (29%) patients of these patients experienced out-of-hospital 30-day mortality. Cardiovascular and pulmonary etiologies accounted for the majority of observed mortality. Multivariable regression analysis identified older age, gender, lower body surface area, lower left ventricular ejection fraction, lower hemoglobin, atrial fibrillation or flutter, severe lung disease, home oxygen use, lack of moderate-to-severe aortic insufficiency, urgent TAVR, lower Kansas City Cardiomyopathy Questionnaire score, longer hospital length of stay, and in-hospital complications as being independently associated with the primary endpoint. New onset or pre-existent atrial fibrillation or flutter was also independently associated with 30-day out-of-hospital cardiovascular mortality in the transfemoral population.ConclusionsWe identified 30-day all-cause mortality rate for TAVR of 2.2%. Approximately one-third of patients experienced out-of-hospital mortality at 30 days. Several factors were identified as being independently associated with 30-day out-of-hospital all-cause and cardiovascular mortality. Further work is needed to understand how best to improve out-of-hospital mortality following TAVR.  相似文献   

20.
ObjectivesThis study compared clinical outcomes and revascularization strategies among patients presenting with low ejection fraction, low-gradient (LEF-LG) severe aortic stenosis (AS) according to the assigned treatment modality.BackgroundThe optimal treatment modality for patients with LEF-LG severe AS and concomitant coronary artery disease (CAD) requiring revascularization is unknown.MethodsOf 1,551 patients, 204 with LEF-LG severe AS (aortic valve area <1.0 cm2, ejection fraction <50%, and mean gradient <40 mm Hg) were allocated to medical therapy (MT) (n = 44), surgical aortic valve replacement (SAVR) (n = 52), or transcatheter aortic valve replacement (TAVR) (n = 108). CAD complexity was assessed using the SYNTAX score (SS) in 187 of 204 patients (92%). The primary endpoint was mortality at 1 year.ResultsLEF-LG severe AS patients undergoing SAVR were more likely to undergo complete revascularization (17 of 52, 35%) compared with TAVR (8 of 108, 8%) and MT (0 of 44, 0%) patients (p < 0.001). Compared with MT, both SAVR (adjusted hazard ratio [adj HR]: 0.16; 95% confidence interval [CI]: 0.07 to 0.38; p < 0.001) and TAVR (adj HR: 0.30; 95% CI: 0.18 to 0.52; p < 0.001) improved survival at 1 year. In TAVR and SAVR patients, CAD severity was associated with higher rates of cardiovascular death (no CAD: 12.2% vs. low SS [0 to 22], 15.3% vs. high SS [>22], 31.5%; p = 0.037) at 1 year. Compared with no CAD/complete revascularization, TAVR and SAVR patients undergoing incomplete revascularization had significantly higher 1-year cardiovascular death rates (adj HR: 2.80; 95% CI: 1.07 to 7.36; p = 0.037).ConclusionsAmong LEF-LG severe AS patients, SAVR and TAVR improved survival compared with MT. CAD severity was associated with worse outcomes and incomplete revascularization predicted 1-year cardiovascular mortality among TAVR and SAVR patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号