1.
Root ZX根尖电测仪测定根管长度的准确性评价   总被引:9,自引:1,他引:9  
目的:评价Root ZX根尖电测仪测定根管长度的准确性。方法:49颗(70个根管)根尖发育完全、因正畸需拔除的牙齿在局麻下,开髓、拔髓。Root ZX根尖电测仪测定根管长度,拔除后测定根管实长,比较二者的差异。分别以0.5mm、1.0mm、1.5mm误差评定测量结果的准确性。结果:体内测量平均根管长度为20.81mm,体外测量根管实际长度为21.21mm。84.29%(59/70)测量值位于根管内,8.57%(6/70)恰好位于根尖孔,7.14%(5/70)超出根尖孔。以0.5mm为标准,准确率为64.29%,以1.0mm为标准,准确率为81.43%。若以1.5mm以内为可接受范围,则准确率为90%。结论:Root ZX根尖电测仪能较准确测定根管工作长度,提高根管治疗的质量和工作效率。但仍需和X线照片结合指导临床工作。  相似文献   

2.
应用根尖电测仪测定根管长度准确性评定   总被引:3,自引:0,他引:3  
目的:评定JUSTY-Ⅱ型全自动根尖电测仪在根管工作长度测定中的准确性。方法:选择80例病牙,120个根管,采用全自动根尖电测仪对根管工作长度进行测定,并与插针X线摄片法进行对比。结果;根尖电测仪测定根管工作长度的准确率为89.17%,插针X线摄片法测定根管工作长度的准确率为34.17%,二组有显著性差异(P<0.01)。结论:应用全自动根尖电测仪测定根管工作长度具有准确性高,减少患者X线损害,缩短临床椅位工作时间和提高根管治疗质量的优点。  相似文献   

3.
目的 探讨根管扩大程度对根管长度电测仪准确性的影响.方法 收集根尖发育完全、根管通畅的离体牙45颗,用回旋手机和ISO标准型不锈钢根管锉扩大根管,测量扩大前、常规扩大后和过度扩大后的电测长度、实测长度,并进行统计分析.结果 ①电测长度与实测长度误差为0时,根管扩大前、常规扩大后、过度扩大后准确率为97.06%、 90.91%、 80.00%;误差在±0.5 mm时,根管扩大前、常规扩大后、过度扩大后准确率为98.53%、95.45%及86.67%;根管扩大前和常规扩大后差异无统计学意义,扩大前和过度扩大后差异有统计学意义,常规扩大和过度扩大后差异无统计学意义.②后牙根管过度扩大后实测长度短于原始实测长度的发生率达40.38%,与常规扩大组发生率3.45%相比,差异有统计学意义.结论 NeosonoTM电测仪准确性随根管及根尖孔的扩大而呈现下降趋势;ISO标准型不锈钢根管锉常规扩大根管对电测仪准确性影响不大,过度扩大会显著降低电测仪的准确性.  相似文献   

4.
两种牙齿操作长度电测仪准确性的体外研究   总被引:10,自引:0,他引:10  
目的:测试Tri Auto ZX和JUSTYⅡ牙齿操作长度电测仪对根尖孔定位的准确性,并评价根尖孔大小对准确性的影响。方法:分别用Tri Auto ZX和JUSTYⅡ测定42个离体根管“APEX”读数的电测操作长度,计算测量偏差和准确率。测定并分析根尖孔面积、直径及其与测量偏差之间的关系。结果:Tri Auto ZX的测量偏差显著低于JUSTY Ⅱ(P<0.01)。距解剖根尖孔±0.5mm与±1.0mm范围内准确率显著高于JUSTYⅡ(P<0.01)。根尖孔面积与两电测仪测量偏差均有显著正相关关系(P<0.01)。Tri Auto ZX能够进行准确测量的临界根尖孔面积大于JUSTY Ⅱ。结论:本实验模型中以解剖根尖孔为参考点,Tri Auto ZX的“APEX”读数处准确性优于JUSTYⅡ;Tri Auto ZX可在更大根尖孔范围内准确测量。  相似文献   

5.
目的:评价第四代小卫星根管诊断机(Diagnostic SybronEndo)测量根管工作长度的准确性。方法:选择根尖孔发育完成的48个单根管且外形比较直的离体前牙,用15#K锉首先通过电子游标卡尺测量根管实际长度(L),得到实际工作长度值LA(LA=L-0.5 mm).在生理盐水琼脂模型上,在根管干燥状态下通过Diagnostic测量根管工作长度LD(电子测量仪显示距离解剖根尖孔0.5mm时根管长度),比较LA与LD之间的差值(IF值)并进行统计学分析。分别在根管内浸润有3%H2O2、0.9%NaCl、1.0%NaClO3情况下,用Diagnostic测量根管工作长度LD,分析比较在不同根管内容物状态下对Diagnostic测量值的影响。结果:以IF值在±0.5 mm为标准,Diagnostic在根管干燥状态下的测量准确率为93.4%。统计学分析显示根管在干燥状态和使用不同冲洗液体浸润根管时,Diagnostic测量根管工作长度LD值间的差异无统计学意义(P>0.05)。结论:Diagnostic测量根管工作长度的准确性不受根管内容物的影响,Diagnostic可以较为准确地测量出根管工作长度。  相似文献   

6.
陈燕  杨明华  李升  李晓玲 《口腔医学》2007,27(7):370-371
目的初步探讨RootZX根管长度电测仪测定老年人根管工作长度的准确性及不同根髓状态对其测量准确性的影响。方法选择老年患者需作根管治疗的患牙204颗,根管373个,随机分为电测法组和手感法组,分别测定根管的工作长度后预备根管,X线片试尖测定牙齿的长度,比较电测法组和手感法组测定根管工作长度的准确率。以及不同根髓状态对电测法测定根管工作长度准确率的影响。结果电测法组、手感法组准确率分别为93.75%、67.96%。经χ2检验,两组间有显著性差异。电测法中活髓根管准确率为93.81%,死髓根管的准确率为93.68%。经χ2检验,两组准确率无显著性差异。结论RootZX测量老年人根管工作长度的准确率明显高于手感法,其准确性不受根髓状态的影响。  相似文献   

7.
根管干湿状态对电测根管长度准确性的影响   总被引:2,自引:0,他引:2  
目的评价根管干湿状态对ROOT ZX测定根管工作长度的准确性的影响。方法21颗根尖发育完成的单根管牙,用ROOT ZX根管长度电测仪分别测量根管在干、湿状态时的根管工作长度,与拔牙后所测实际值比较,并进行统计学分析。结果根管干、湿状态下ROOT ZX的电测值与实际值间的差异均无统计学意义(P>0.05)。结论对于根尖孔已发育完成的患牙,根管干、湿状态对ROOT ZX测量根管工作长度的准确性无影响。  相似文献   

8.
目的:通过对体外牙根管的测量,比较TCM Endo V和Tri Auto ZX两种根管测量仪在根管再治疗病例中的测量精度。方法:选择人新鲜拔除根尖发育完备具有较直单根管的上下颌切牙46个,使用不锈钢锉测量实际工作长度后进行根管预备充填,采用两种根管测量仪对充填后根管使用自动回旋模式和非回旋电测量模式进行测量,对比两种测长仪的精确性。结果:两种设备均可获得精确的根尖长度。两种系统在回旋模式测得的值(ARL)均超出了真实工作长度(TL)和非回旋模式测得的值(EL)。结论:自动回旋模式和非回旋模式相比有明显差异(P<0.05),ARL较TL和EL偏大。非回旋模式下测量更精确,Tri AutoZX系统精确性更高。  相似文献   

9.
10.
副根管对根管长度电测法准确性影响的临床研究   总被引:7,自引:0,他引:7  
目的 探讨副根管对根管长度电测法准确性的影响。方法 X线牙片示有副根管透射影像的患牙14例(A组),无副根管透射影像患牙14例(B组),分别用Root ZX测根管长度。作为电极的H锉在根尖1/3区上下移动,测量两次结果L1和L2,记录两者之间的差值ΔL,以L1为长度插入H锉摄牙片X_1,以L2为长度完成根充,摄牙片X_2。结果 A组10例L1相似文献   

11.
根管长度电测法准确性及其影响因素的探讨   总被引:5,自引:0,他引:5  
目的:探讨JUSTY-Ⅱ电测仪测量根管工作长度的准确性及其影响因素。方法:选择148颗患牙,其中牙髓炎71颗,牙髓坏死46颗,根尖周炎31颗。随机分为2组,分别用指感法和电测法测量根管工作长度,以X线片影像为参照,用χ2检验比较其结果,并分析各临床病变类型、根管干湿状态和根管扩大等因素对电测法准确性的影响。结果:电测法准确率为87.84%,指感法为43.24%,2组有高度显著性差异(P<0.01)。根尖周炎组准确率与牙髓炎组、牙髓坏死组有显著性差异(P<0.05)。根管干湿状态对测量结果无影响,扩根前后准确率有显著性差异(P<0.05)。结论:电测法是一种准确、操作简便的测量根管工作长度的方法。根尖周组织的炎症以及根管扩大,均会降低其准确性。  相似文献   

12.
目的评价电子根尖定位仪测量根管工作长度进行根管充填的质量。方法选取2007年8月至2008年4月郑州市第一人民医院口腔科门诊经X线及临床检查确诊为牙髓病及根尖周病需作根管治疗的患牙136颗,共265个根管。按患者就诊顺序编号,随机分成实验组(141个根管)和对照组(124个根管)。实验组的根管工作长度用电子根尖定位仪测定,对照组的根管工作长度用X线拍片法测定。两组均用逐步后退法根管预备,侧方加压法根管充填,以X线拍片检验根管充填质量。结果实验组适充率为86.52%,对照组适充率为76.61%,两组间差异有统计学意义(P<0.05)。结论采用根尖定位仪测量根管工作长度能明显提高根管充填质量。  相似文献   

13.
根管长度测定仪的精确性评估   总被引:2,自引:0,他引:2  
目的评估ROOTZX根管长度测量仪临床应用中的精确性。方法应用日产ROOTZX电子根管长度测定仪测量176个前牙根管的长度,摄X线片后,测量针尖到根尖的距离,再与离休牙根失到根尖孔的距离做比较;进行统计分析。结果它们之间无显著性差异。结论此种方法能较精确地测量根管长度,有较高的临床应用价值。  相似文献   

14.
目的研究Raypex 5和Elements Diagnostic 2种根尖定位仪测量根管长度的准确性。方法收集40颗单根管下颌前磨牙,首先借助K锉测定实际根管长度,然后再分别使用Raypex 5和Elements Diagnostic 2种根尖定位仪测定根管长度,得到电测长度与实际长度的差值,对结果进行分析比较。结果 Raypex 5根管长度测量的准确率是87.5%,Elements Diagnostic 92.5%,两者准确率差异无统计学意义(P>0.05)。结论临床使用2种根尖定位仪对根管长度的确定都是较为精确和有效的。  相似文献   

15.
Aim To evaluate ex vivo the accuracy of two electronic apex locators during root canal length determination in primary incisor and molar teeth with different stages of physiological root resorption. Methodology One calibrated examiner determined the root canal length in 17 primary incisors and 16 primary molars (total of 57 root canals) with different stages of root resorption based on the actual canal length and using two electronic apex locators. Root canal length was measured both visually, with the placement of a K‐file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using two electronic apex locators (Root ZX II – J. Morita Corp. and Mini Apex Locator – SybronEndo) according to the manufacturers’ instructions. Data were analysed statistically using the intraclass correlation (ICC) test. Results Comparison of the actual root canal length and the electronic root canal length measurements revealed high correlation (ICC = 0.99), regardless of the tooth type (single‐rooted and multi‐rooted teeth) or the presence/absence of physiological root resorption. Conclusions Root ZX II and Mini Apex Locator proved useful and accurate for apex foramen location during root canal length measurement in primary incisors and molars.  相似文献   

16.
根尖定位仪测量根尖破坏牙根管长度的准确性研究   总被引:5,自引:0,他引:5  
目的 比较Root ZX,Propex,Justy Ⅱ和 Raypex5 4种根尖定位仪测量根尖受破坏牙齿工作长度的准确性.方法 将53颗离体牙沿釉牙骨质界截冠、去髓,根管预备到25#,使用Root ZX(A组),Propex(B组),Justy Ⅱ(C组)和 Raypex5(D组) 4种根尖定位仪分别测量每个根管的工作长度;再使用超声倒预备工作尖将以上各牙沿根尖孔破坏根尖狭窄部,再次用4种根尖定位仪测量工作长度.结果 所得数据与解剖镜下测量的实际数据进行比较,根尖完整时A、B、C、D4组数据在-0.5~0.5 mm误差范围内的百分数分别为86.3%、88.8%、85.0%、88.8%.根尖破坏时A、B、C、D4组数据在-0.5~0.5 mm误差范围内的百分数分别为16.7%、20.5%、10.3%、48.7%,在-1~1 mm误差范围内的百分数分别为74.4%、52.6%、57.7%、91.0%.结论 4种根尖定位仪对于根尖破坏的牙齿测量准确性比根尖完整的牙齿要低,相比之下Raypex5的准确性比较高.  相似文献   

17.
It is generally accepted that root canal treatment procedures should be confined within the root canal system. To achieve this objective the canal terminus must be detected accurately during canal preparation and precise control of working length during the process must be maintained. Several techniques have been used for determining the apical canal terminus including electronic methods. However, the fundamental electronic operating principles and classification of the electronic devices used in this method are often unknown and a matter of controversy. The basic assumption with all electronic length measuring devices is that human tissues have certain characteristics that can be modelled by a combination of electrical components. Therefore, by measuring the electrical properties of the model, such as resistance and impedance, it should be possible to detect the canal terminus. The root canal system is surrounded by dentine and cementum that are insulators to electrical current. At the minor apical foramen, however, there is a small hole in which conductive materials within the canal space (tissue, fluid) are electrically connected to the periodontal ligament that is itself a conductor of electric current. Thus, dentine, along with tissue and fluid inside the canal, forms a resistor, the value of which depends on their dimensions, and their inherent resistivity. When an endodontic file penetrates inside the canal and approaches the minor apical foramen, the resistance between the endodontic file and the foramen decreases, because the effective length of the resistive material (dentine, tissue, fluid) decreases. As well as resistive properties, the structure of the tooth root has capacitive characteristics. Therefore, various electronic methods have been developed that use a variety of other principles to detect the canal terminus. Whilst the simplest devices measure resistance, other devices measure impedance using either high frequency, two frequencies, or multiple frequencies. In addition, some systems use low frequency oscillation and/or a voltage gradient method to detect the canal terminus. The aim of this review was to clarify the fundamental operating principles of the different types of electronic systems that claim to measure canal length.  相似文献   

18.
目的:初步探讨根管治疗仪在确定老年人磨牙根管工作长度方面的准确性.方法:随机选取须进行根管治疗的老年人磨牙132颗,实验组86颗分为治疗仪组和手感法组,治疗仪组患牙44颗,共131个根管,采用TRIAUTO ZX根管治疗仪确定工作长度,手感法组42颗,共126个根管,采用手感法确定工作长度;对照组46颗为X线片组作为标准组;所有根管预备后插诊断丝摄X线片,比较实验组和标准组测定工作长度的准确率.结果:治疗仪组131个根管中符合工作长度标准的有125个,准确率为95.42%;手感法组126个根管中符合工作长度标准的有103个,准确率为81.75%;标准组146个根管中符合工作长度标准的有139个,准确率为95.21%.X2检验显示,治疗仪组同对照组相比差异无显著性;手感法组同对照组相比差异有显著性.结论:根管治疗仪在老年人根管治疗中,对磨牙根管工作长度的测定方面,比手感法有更高的准确率,与X线片法可取得同样的效果.  相似文献   