首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 93 毫秒
1.
目的:探讨全自动定位跟踪系统辅助Contoura矫正屈光不正伴轻度角膜不规则散光的安全性、有效性、可预测性、稳定性及居中性。方法:前瞻性临床研究。选择2016 年3-6 月在杭州明视康眼科医院行全自动定位跟踪系统辅助Contoura手术的屈光不正伴轻度角膜不规则散光患者23 例(40 眼),分别于术前及术后1 d、2 周、3 个月检查裸眼视力(UCVA)、最佳矫正视力(BCVA),并行电脑验光、显然验光、三维角膜地形图、裂隙灯显微镜检查等。应用Pearson相关分析对术后不同随访时间的实际矫正等效球镜度(SE)与预矫正SE进行相关分析,应用单因素方差分析对不同时间点的UCVA、SE、偏心距进行比较。结果:术后1 d、2 周、3 个月随访时,UCVA分别为-0.04±0.08、-0.06±0.08、-0.06±0.08,且BCVA均达到或高于术前水平,其中术后3 个月时BCVA较术前BCVA提高1行有13眼(32.5%),提高2行有1眼(2.5%)。术后3个月时实际矫正SE与预矫正SE呈正相关(r =0.999,P < 0.001),其中SE偏差量±0.50 D以内占100%,SE偏差量±0.25 D以内占37.5%。术后各时间点间UCVA、SE差异均无统计学意义。术后1 d和3 个月偏心距差异有统计学意义(P=0.02),其余各时间点间差异均无统计学意义。术中及术后3 个月随访时无严重并发症发生。结论:全自动定位跟踪系统辅助Contoura矫正屈光不正伴轻度角膜不规则散光临床效果肯定,具有较好的安全性、有效性、可预测性、稳定性及居中性。  相似文献   

2.
目的 探讨角膜地形图引导下准分子激光个性化切削手术矫正角膜不规则散光及不对称性散光的效果和优缺点.方法 应用MEL - 70准分子激光仪及配套TOMEY -Ⅲ角膜地形图引导个性化切削系统进行准分子激光原位角膜磨镶术(LASIK)矫正不对称性或不规则角膜散光复性近视散光58例108眼.其中49例97眼为初次手术;另9例11眼为二次手术,系由不均匀切削、偏心切削或中央岛而形成的不规则散光.术前最佳矫正视力均值0.98±0.32;屈光度:球镜平均(-4.59±1.68)D,柱镜平均(-1.62±0.78)D.结果 108眼手术均顺利完成,无术中或术后并发症.术后角膜地形图显示:角膜中央3 mm切削深度平整、均匀,术后1周平均裸眼视力1.03 ±0.29.屈光度:球镜-0.50~+0.75D,平均(-0.35 ±0.29)D,柱镜0~- 0.75D,平均(-0.38 ±0.24)D.结论 TOMEY -Ⅲ角膜地形图捕捉角膜曲率信息准确,引导准分子激光个性化切削程序设计合理,系统安全可靠.用它来进行个性化LASIK可较为精确地矫正角膜不规则及不对称散光.  相似文献   

3.
目的 探讨飞秒激光弧形角膜切开术对白内障合并角膜散光患者的矫正效果。方法 选取33例(36眼)白内障合并角膜散光≥0.75 D的患者作为研究对象,均行飞秒激光弧形角膜切开术来矫正角膜散光。术前测患者裸眼远视力、最佳矫正远视力,用Pentacam三维眼前节分析系统测量角膜散光。行飞秒激光辅助的超声乳化白内障手术,术中弧形切口直径为9 mm,深度为90%。术后3个月时复查患者角膜散光、裸眼远视力、最佳矫正远视力,并用Alpins矢量分析法进行散光分析,主要观察以下矢量数据,即目标诱导散光向量、手术诱导散光向量、差异向量和矫正指数。结果 术前患者角膜散光为(1.16±0.35)D,术后3个月下降到(0.54±0.22)D,差异有统计学意义(P<0.01)。术前裸眼远视力为0.81±0.42,术后3个月提高到0.26±0.24,差异有统计学意义(P<0.01)。术前最佳矫正远视力为0.76±0.30,术后3个月提高到0.09±0.12,差异有统计学意义(P<0.01)。对患者术前术后角膜散光的变化进行矢量分析显示,目标诱导散光向量为0.80~2.20(1.16±0.35)D,手术诱导散光向量为0.40~1.80(1.07±0.40)D,差异向量为0.20~1.00(0.54±0.22)D。矫正指数为0.89±0.35,理想值为1,提示总体为少许欠矫。大部分患眼(32眼)角度误差在15°范围内。成功指数平均值为0.47,提示还残留部分散光未得到矫正。通过公式计算可以得到散光矫正的成功率为53.0%。变平效果平均值为0.94,变平指数平均值为0.83。结论 飞秒激光弧形角膜切开术能有效矫正白内障合并角膜散光患者的角膜散光。  相似文献   

4.
目的:研究白内障术中飞秒激光弧形角膜切开术(FSAK)矫正术前角膜散光的临床疗效。方法:回顾性病例对照研究。连续纳入北京爱尔英智眼科医院2017年3月至2021年12月术前规则角膜散光为0.75~2.00 D且接受飞秒激光辅助白内障手术的患者89例(89眼)。所有患者按照术前角膜散光轴位分为顺规散光组(90°±30°)、逆规散光组(180°±30°)及斜轴散光组(45°±15°、135°±15°)。飞秒激光辅助白内障手术及弧形角膜切开术使用Lensx平台。观察患者总体和顺规、逆规散光组术前及术后3个月角膜散光的变化及分布情况。使用配对样本t检验或Wilcoxon符号秩检验比较总体及各亚组术前、术后的散光差异;使用独立样本t检验或Mann-Whitney U检验比较顺规散光组及逆规散光组的差异;散光变化的分析采用Alpins矢量分析法。结果:纳入的89例(89眼)患者中,顺规散光组38例,逆规散光组44例,斜轴散光组7例。所有患者角膜水平径为(11.48±0.57)mm,垂直径为(10.66±0.60)mm。患者总体术后裸眼远视力、最佳矫正远视力相比术前有显著改善(Z=8.01、-7.49,P<0.001)。总体术前角膜散光为(1.28±0.33)D,术后3个月残余散光(0.67±0.37)D,散光矫正量为(0.61±0.33)D。顺规及逆规散光组角膜散光矫正量分别为(0.48±0.27)D、(0.74±0.34)D。总体及顺规、逆规散光组术后平坦轴角膜曲率均有明显升高,而陡峭轴角膜曲率则出现明显下降。矢量分析法显示总体散光矫正指数为0.63±0.30,平坦指数为0.58±0.30,成功指数为0.51±0.25,误差角为-1.83°±12.59°。逆规散光组矫正效果最佳,矫正指数为0.81±0.25,平坦指数为0.75±0.26,成功指数为0.40±0.24;顺规散光组次之,矫正指数为0.42±0.21,平坦指数为0.39±0.21,成功指数为0.63±0.21。结论:白内障术中FSAK矫正术前角膜散光具有良好的有效性和安全性,相同的弧形切口设计方式在逆规散光中取得了更好的疗效,角膜直径可能是产生影响的重要因素。  相似文献   

5.
目的 评估飞秒激光联合对称弧形角膜切口对白内障合并角膜散光患者的治疗效果。方法 前瞻性研究。收集43例(57眼)白内障合并≥0.75 D角膜规则散光的患者,均行飞秒激光超声乳化白内障手术,术中同时采用对称弧形角膜切口矫正角膜散光。弧形切口设置在角膜直径中央8.0 mm处,深度为角膜厚度的85%,术中开口器分离弧形切口。术前及术后均采用Pentacam三维眼前节分析系统记录角膜散光。采用Alpins矢量法分析术后角膜散光变化,并分析散光类型、年龄与散光矫正效果的相关性。结果 术中及术后所有患者均未出现角膜穿透、上皮损伤、角膜上皮增生、切口感染等并发症。术前患眼角膜散光为(1.23±0.31)D,术后3个月患眼角膜散光下降到(0.85±0.34)D,差异有统计学意义(t=4.645,P=0.000)。对患者手术前后角膜散光的变化进行矢量分析,结果显示,目标诱导散光为0.80~2.10(1.23±0.31)D,手术诱导散光为0.00~1.80(0.68±0.45)D,差异向量为0.26~1.70(0.89±0.42)D,矫正指数为0.00~1.01(0.55±0.27),理想值为1,提示总体...  相似文献   

6.
目的 探讨角膜基质透镜散光标记器(简称散光标记器)在角膜基质透镜植入术矫正远视及散光中的应用.方法 前瞻性病例研究.选取2019年12月至2020年12月在南昌大学附属眼科医院屈光科就诊的满足手术要求的远视及散光患者6例6眼,年龄20~36(27.50±6.72)岁,所有患者均行飞秒激光辅助的瓣下角膜基质透镜植入术(F...  相似文献   

7.
目的:评价角膜地形图引导的准分子激光个性化切削治疗准分子激光原位角膜磨镶术( LASIK)术后不规则散光的临床疗效。方法选取2013年2月至2015年8月在我院就诊的患者9例(10只眼),均为LASIK术后存在一定程度的偏中心或不规则散光。在角膜地形图引导下行准分子激光切削,比较手术前后视力、散光度、角膜不规则指数( CIM)及高阶像差均方根( High RMS)。结果患者术后裸眼视力由平均0.50±0.13变为术后3个月平均0.98±0.11,差异具有统计学意义( P =0.00)。手术前散光绝度值1.00 D~2.50 D,平均为(1.78±0.39)D,术后3个月平均(0.62±0.22)D,手术前后差异具有统计学意义。术后CIM及High RMS均较术前下降,差异均具有统计学意义( P =0.00)。结论 CRS-MASTER平台角膜地形图引导的准分子激光治疗LASIK术后不规则散光安全、有效。  相似文献   

8.
目的 观察硬性透气性角膜接触镜(RGPCL)矫正圆锥角膜完成期患者不规则散光的临床效果.设计病例系列研究. 研究对象圆锥角膜完成期患者20例(22眼). 方法采用多功能视力测量仪MFVA100分别测试20例(22眼)圆锥角膜患者裸眼(UCVA)、最佳框架矫正(BSCVA)和RGPCL矫正状态下100%、25%、10%和5%的4种对比度视力.角膜荧光染色法和相干光断层成像术(OCT)观察镜片下泪液的分布情况,判断RGPCL的静态配适状态.用单因素方差分析、LSD法两两比较相同对比度下3组视力之间的差别.主要指标对比度视力.结果 22眼在100%、25%、10%和5%对比度下平均UCVA分别为0.195、0.098、0.053、0.042(P均〈0.05),平均BSCVA分别为0.421、0.205、0.116、0.064(P〈0.05),平均RGPCL矫正视力分别为0.880、0.520、0.308、0.169(P均〈0.05).在100%、25%、10%和5%四种对比度下RGPCL的矫正视力均优于UCVA和BSCVA(P均=0.000),而在5%对比度下UCVA与BSCVA无显著差异(P=0.142).22眼RGPCL矫正后荧光素染色裂隙灯钴蓝灯光下见呈稍平坦配适、大曲率子午线上泪液填充较多、边缘部泪液宽度适中.戴镜后用前节OCT扫描中央光学区角膜显示出大、小曲率子午线上镜片下泪液分布厚度不同.结论 RGPCL可矫正圆锥角膜完成期患者的不规则散光,明显提高圆锥角膜患者不同对比度下的矫正视力.  相似文献   

9.
近视眼LASIK术后角膜不规则散光的临床分析   总被引:2,自引:0,他引:2  
目的 :定量分析LASIK术后角膜不规则散光改变与激光切除量的关系。方法 :对近视眼行LASIK手术 ,术前和术后一个月测量角膜地形图 ,计算角膜不规则散光 ,采用傅立叶函数分析方法对数据进行分析。结果 :LASIK术后 ,角膜不规则散光的程度明显增高 (P <0 .0 0 0 1) ,不规则散光程度与切削的深度显著相关 (r =0 .44 0 ,P <0 .0 0 0 1)。结论 :LASIK手术明显增高角膜的不规则散光 ,其不规则散光的程度与激光切削量密切相关。  相似文献   

10.
近视眼全眼散光及角膜散光对LASIK术矫正近视散光的影响   总被引:1,自引:0,他引:1  
目的:探讨全眼散光和角膜散光对LASIK手术矫正散光的影响。方法:回顾性分析84例162眼行LASIK手术矫正的近视散光患者,根据全眼散光与角膜散光轴向相差<15°,全眼散光度数<2倍角膜散光度数和全眼散光与角膜散光轴向相差≥15°,全眼散光度数≥2倍角膜散光度数分为A(112眼)、B(50眼)两组,分析术后视力、散光矫正效果。结果:患者中69%的全眼散光轴与角膜散光轴向相关,差异在15°以内,术后两组眼散光度数分别为-0.39±0.43,-0.73±0.21D,差异有统计学意义(P<0.05)。B组有4例患者主诉夜晚有眩光,近视力差、疲劳。结论:近视眼全眼散光与角膜散光有高度相关性。LASIK矫正散光术前应根据验光和角膜地形图结果分析,合理设计散光的切削量和轴位,选择个性化治疗方案。  相似文献   

11.
AIM: To evaluate the visual outcomes of Contoura Vision (CV) with automatic eye tracking system in eyes with myopia and myopic astigmatism. METHODS: This prospective study included 160 eyes (80 patients) with moderate myopia and irregular astigmatism between January and August 2018. Subjects were randomly divided into CV group (80 eyes) that underwent CV femtosecond laser-assisted in situ keratomileusis (FS-LASIK) and a control group (80 eyes) that underwent wavefront-optimized FS-LASIK. Visual outcomes and astigmatic vector analysis were evaluated and compared between preoperatively and 3mo postoperatively. RESULTS: Basic details were similar in both groups (P>0.05). At 3mo postoperatively, uncorrected distance visual acuity was 20/16, 20/20, and 20/25 in 24, 76, and 80 eyes of patients in CV group, respectively. The CV group was better in predictability of astigmatism correction at 3mo postoperatively. In CV group, 64 eyes had deviation of astigmatic axis within 15° and 28 eyes had deviation of astigmatic axis within 5°, both were better than those in the control group. The number of eyes with residual astigmatism within 0.5 D were less in CV group (48 eyes) than the control group (40 eyes). Compared with the preoperative, C7 significantly reduced to 0.056±0.030 in CV group at 3mo after the procedure (P<0.05), and were significantly lower than those in the control group (P<0.05). CONCLUSION: CV with automatic eye tracking system is safe and effective for the correction of myopia and myopic astigmatism.  相似文献   

12.
目的:探讨飞秒激光小切口角膜基质透镜取出术治疗近视及散光的有效性、可预测性、稳定性和安全性.方法:前瞻性临床对照研究.近视及近视散光患者547例1 080眼,按患者选择的手术方式分为两组,小切口角膜基质透镜取出术(small incision lenticule extraction,SMILE)组285例560眼,飞秒激光辅助的准分子激光原位角膜磨镶术(femtosecond laser assisted laser in situ keratomileusis,FS-LASIK)组262例520眼.术后随访12mo,分别于术后第1d,1wk,1、6、12mo复查,检查裸眼及矫正视力、屈光度、裂隙灯及角膜地形图,并测量偏中心切削值.结果:术后第1d,1wk,1、6、12mo,SMILE组的裸眼视力(uncorrected visual acuity,UCVA,以LogMAR视力表示)分别为0.029±0.13、0.001±0.11、-0.019±0.11、-0.020±0.08、-0.011±0.10;FS-LASIK组分别为-0.017±0.08、-0.019±0.09、-0.031±0.10、-0.024±0.09、-0.002±0.12;术后1d和1wk,SMILE组视力低于FS-LASIK组,两组比较差异有统计学意义(P<0.05),其它时间点差异无统计学意义(P>0.05).术后1、6、12mo,SMILE组的等效球镜(spherical equivalent,SE)分别为-0.03±0.29、-0.04±0.28、-0.06±0.32D;FS-LASIK组分别为0.02±0.20、-0.01±0.29、-0.08±0.33D,两组比较术后1mo的结果差异有统计学意义(P<0.05),其余时间点两组的差异无统计学意义(P>0.05).术后3mo,SMILE组测量的偏中心切削值为0.21±0.11mm,FS-LASIK组为0.20±0.08mm,两组比较差异无统计学意义(P>0.05).结论:SMILE治疗近视及近视散光有良好的有效性、可预测性、稳定性和安全性,但与FS-LASIK比较,术后早期视力恢复慢.  相似文献   

13.
周晶  皇甫晓瑾 《国际眼科杂志》2014,14(11):2034-2036
目的:飞秒微透镜切除术( femtosecond lenticule extraction, FLEx)治疗中高度近视及近视散光并与标准的准分子激光原位角膜磨镶术( laser in situ keratomileusis,LASIK)比较并随访观察6mo,证实飞秒微透镜切除术提高患者术后视觉质量更有优越性。
  方法:随机选取行角膜屈光手术的中高度近视及近视散光(球镜度数-3.00~-10.00D,散光度≤-6.0D)患者共86例172眼,分为两组进行研究,86眼使用FLEx ( A组),86眼使用标准的LASIK(B组),跟踪随访6mo,记录术后总高阶像差、球差、裸眼视力、最佳矫正视力、客观验光值、裂隙灯检查、术后有无并发症、眼压、角膜地形图。
  结果:所有患者手术均成功,FLEx术后总高阶像差和球差的增加量较LASIK术少。
  结论:飞秒微透镜切除术矫正高度近视和近视散光在提高视觉质量方面有明显优越性。  相似文献   

14.
周晶  皇甫晓瑾 《国际眼科杂志》2014,14(10):1797-1800
目的:飞秒激光角膜基质透镜切除( femtosecond lenticule extraction,FLEx )术治疗中高度近视散光并与标准的LASIK术比较,探讨FLEx术的安全性、有效性、可预测性。方法:随机选取行角膜屈光手术的中高度近视散光(近视度数-3.00~-10.00D,散光度≤-6.00D)患者86例172眼,分为两组进行研究,86眼使用FLEx术( A组),86眼使用标准准分子激光原位角膜磨镶术( laser in situ keratomileusis,LASIK)(B组),随访6mo,记录术后裸眼视力、最佳矫正视力、客观验光值、裂隙灯检查、术后有无并发症、角膜瓣厚度、眼压、角膜地形图。
  结果:术后6mo,两组最佳矫正视力提高一行以上的所占比例差异有统计学意义(P<0.05),A组高于B组;两组残余屈光度数在±0.50D内所占比例(A组83.7%,B组53.4%)有统计学差异(P<0.05);裸眼视力在1.0及1.0以上的A组占100%,B组占90.7%,差异有统计学意义(P<0.05)。结论:FLEx术比传统的LASIK手术具有更好的安全性、可预测性和有效性。  相似文献   

15.

目的:评估非散光型后房型人工晶状体矫正高度近视伴中度散光的有效性及安全性。

方法:回顾性分析2013-12/2015-12于我院行非散光型后房型人工晶状体(V4c-ICL)植入术矫正高度近视伴中度散光(-1.00~-2.00D)的患者31例44眼,随访14.52±2.40mo,观察手术前后视力、眼压、前房深度、角膜内皮细胞计数及术后拱高、并发症、患者满意度等情况。

结果:末次随访时,本组患者有效指数为1.38±0.35,安全指数为1.42±0.30,裸眼视力和矫正视力(LogMAR)均优于术前(0.05±0.15 vs 1.48±0.29; 0.03±0.12 vs 0.18±0.15; 均P<0.05),前房深度低于术前(2.22±0.28mm vs 3.19±0.20mm,P<0.05),而眼压和角膜内皮细胞计数均与术前无差异(P>0.05)。至末次随访,本组患者均未发生严重的眼部并发症,总满意度为94%。

结论:非散光型后房型人工晶状体矫正高度近视伴中度散光安全有效。  相似文献   


16.
准分子激光角膜原位磨镶术治疗高度近视合并中高度散光   总被引:2,自引:5,他引:2  
目的:观察准分子激光原位角膜磨镶术(LASIK)治疗高度近视合并中高度散光的临床疗效。方法:采用准分子激光原位角膜磨镶术治疗43例(79眼)高度近视合并中高度散光患者,屈光度为-6.0~-15.5D,散光为-2.0~-5.0D。结果:术后随访6mo,裸眼视力≥术前矫正视力者占91%,屈光度在±0.75D以内者占86%,残留散光平均为-0.45D。结论:LASIK治疗高度近视伴中高度散光,效果明显,安全可靠。  相似文献   

17.

目的:评估波前像差引导飞秒激光辅助LASIK(femtosecond laser assisted LASIK, FS-LASIK)治疗近视合并中高度散光患者术后高阶像差变化。

方法:纳入我院于2016-07/2017-02收治的近视合并中度至高度散光患者50例88眼。术前51眼散光≥-1.50D且<-3.00D(中度散光),37眼散光≥-3.00D(高度散光),所有患者均接受波前像差引导FS-LASIK手术。术前和术后3mo评估未矫正视力(uncorrected distance visual acuity, UDVA)、矫正视力(corrected distance visual acuity, CDVA)、角膜曲率、角膜中心厚度(central corneal thickness, CCT)和部分高阶像差(higher order aberrations, HOAs)。

结果:术后3mo所有术眼的UDVA均达到20/20以上,均较术前提高且差异有统计学意义(P<0.05),而 CDVA和术前相比差异无统计学意义(P=0.36)。术后85眼(97%)散光在-1.00D以下,70眼(80%)散光在-0.50D以下,差异有统计学意义(P<0.05)。较术前相比,术后平均角膜曲率降低约为3.81±1.97D,CCT减少约78.66±37.22μm,差异有统计学意义(P<0.05)。术后3mo彗差与三叶草较术前无明显变化(P=0.078、0.065); 而球面像差、二次散光及高阶像差均方根(HOA-root mean square, HOA-RMS)术后较术前均有所增加,分别从术前的0.19±0.06、0.05±0.02 和0.42±0.12增加至术后的0.32±0.17、0.26±0.08 和0.78±0.28,差异有统计学意义(P<0.05)。

结论:波前像差引导FS-LASIK术后虽然产生部分高阶像,但依然是中高度散光患者进行角膜屈光手术的一个安全有效的选择。  相似文献   


18.
目的 应用矢量分析法评价眼内散光(ocular residual astigmatism,ORA)对飞秒激光LASIK治疗散光的影响.方法 收集2016年1月至4月在我院行飞秒激光LASIK的患者182例.应用矢量分析法计算ORA,ORA大于等于散光的为高眼内散光组(high ocular residual astigmatism group,HORAG),反之则为低眼内散光组(low ocular residual astigmatism group,LORAG).术后随访6个月,比较两组裸眼视力以及散光矫正率和误差率.结果 术前所有患者ORA为(0.61±0.27)D,其中超过0.75D者58例(31.9%);HORAG患者的ORA大于LORAG患者,两组差异有统计学意义(P<0.05).术后6个月HORAG患者裸眼视力为1.06 ±0.15,LORAG患者裸眼视力为1.08 ±0.15,两组差异无统计学意义(t=0.97、P=0.35);HORAG误差率(58.11±63.23)%大于LORAG(26.12±35.37)%,两组差异有统计学意义(t=3.43、P<0.05);HORAG矫正率(146.45±86.63)%较LORAG(122.56±36.31)%大,两组差异有统计学意义(t=2.81、P<0.05).结论 ORA较大时增加飞秒激光LASIK治疗散光的误差率,影响散光矫正率,进行屈光手术前应进行散光来源分析.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号