首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到16条相似文献,搜索用时 156 毫秒
1.
Sun Y  Zheng DY  Ling SQ  Song TT  Liu YZ 《眼科学报》2012,27(1):5-12
 Purpose: To evaluate visual outcomes after implantation of an aspheric multifocal/ intraocular lens (MIOL) or an aspheric monofocal intraocular lens (IOL). Methods: This was a prospective nonrandomized study. During 3-months of post-operative follow-up, the following outcomes for SN6AD1 MIOL (multifocal group) and SN60WF IOL (monofocal group) were compared: uncorrected (UDVA) and corrected (CDVA) distance visual acuity, uncorrected (UNVA) and distance-corrected (DCNVA) near visual acuity, Chinese character near visual acuity, uncorrected intermediate visual acuity (UIVA) under high (100% contrast) and low contrast (10% contrast), UIVA for different IOL powers, and a quality-of-life questionnaire. Results: UNVA, DCNVA, and UIVA under high contrast in the multifocal group were significantly better than those in the monofocal group (P<0.05). UDVA, CDVA and UIVA under low contrast did not differ between groups at 63 cm and 100 cm (P>0.05). In most of the cases, Chinese character near visual acuity was significantly better in the multifocal group (P<0.05). UNVA and UIVA at 63cm were improved 3 months post-operatively. Better UIVA was found in emmetropic and mild myopic eyes as compared to hyperopic ones. The patients in the multifocal group had a higher degree of satisfaction and performed better on near and intermediate tasks, although with greater complaints of visual disturbance.    Conclusion: The SN6AD1 MIOL provides significantly better UNVA, DCNVA and UIVA under high contrast conditions, and better Chinese character near visual acuity. Patients receiving the SN6AD1 MIOL reported a better quality of vision in spite of more serious visual disturbances. Better UIVA was observed in emmetropic and mildly myopic eyes.  相似文献   

2.
对双眼植入三焦点人工晶状体(IOL)或双焦点IOL术后早期的视觉质量进行比较研究。方法:前瞻性临床研究。选择武汉爱尔眼科医院2017年4月至2018年5月收治的双眼单纯年龄相关性白内障患者52例(104眼),依据患者选择的IOL进行分组,双眼均植入双焦点IOL 26例(52眼)作为双焦点组,双眼均植入三焦点IOL 26例(52眼)患者作为三焦点组,术后随访3个月,观察2组间裸眼远视力(UDVA)、裸眼中视力(UIVA)、裸眼近视力(UNVA)、矫正远视力(BCDVA)、矫正远中视力(DCIVA)、矫正远近视力(DCNVA)、离焦曲线、对比敏感度、波前像差、调制传递函数等,并进行VF-14-CN生活质量问卷满意度及脱镜率调查。数据采用独立样本t检验、Mann-Whitney U检验及χ2 检验进行统计分析。结果:三焦点组UIVA明显优于双焦点组(Z=-2.347,P=0.019),而2组间 UDVA、UNVA、BCDVA、DCIVA、DCNVA差异均无统计学意义。三焦点组在-1.0、-3.0、-3.5、 -4.0 D离焦下视力明显优于双焦点组(Z=-2.619、-2.452、-2.452、-2.147,P=0.009、0.014、0.014、 0.032)。2组间明视及明视眩光对比敏感度差异均无统计学意义。3、5 mm瞳孔直径时,三焦点组眼内总高阶像差、眼内彗差、眼内三叶草差以及全眼总高阶像差、全眼三叶草差均明显低于双焦点组,差异均有统计学意义(P<0.05)。5 mm瞳孔直径时,三焦点组眼内球差明显低于双焦点组(Z=-3.053, P=0.002),余指标组间差异无统计学意义。2组在3、5 mm瞳孔直径时的调制传递函数差异均无统计学意义。2组间VF-14-CN得分、日常生活脱镜率以及患者满意度差异均无统计学意义。结论:与双眼植入双焦点IOL相比,双眼植入三焦点IOL能够为患者带来更好的中间距离视力,但二者在远近视力、视觉质量以及术后生活质量方面相近。  相似文献   

3.
目的:研究多焦点人工晶状体(IOL)植入术后白内障患者的视觉质量及阅读能力。方法:前瞻性临床研究。选择2018年6月至2019年10月于重庆医科大学附属第一医院眼科就诊并行双眼白内障手术的患者共75例(150眼),依据患者选择的IOL进行分组,双眼植入Tecnis ZCB00 IOL 25例(50眼)作为单焦组,双眼植入Tecnis ZMB00 IOL 25例(50眼)作为双焦组,双眼植入AT Lisa tri.839MP IOL 25例(50眼)作为三焦组,对比3组患者术后3个月时的祼眼远视力(UDVA)、祼眼中视力(UIVA)、祼眼近视力(UNVA) (LogMAR)及阅读能力。使用NEI-RQL-42量表中文版评价3组患者术后视觉质量的差异。数据采用卡方检验、方差分析、Kruskal-Wallis检验、Mann-Whitney U检验进行统计分析。 结果:共75例(150眼)患者纳入研究。3组间UDVA差异无统计学意义( H=3.187, P=0.203)。三焦组UIVA(0.2±0.1)优于双焦组(0.3±0.2) ( Z=-2.041, P=0.041)和单焦组(0.3±0.3) ( Z=-2.142, P=0.032)。三焦组UNVA(0.3±0.2)和双焦组UNVA(0.3±0.2)优于单焦组(0.4±0.2) ( t=2.332, P=0.017;t=3.014, P=0.036)。3组阅读视力( F=0.421, P=0.658)、阅读速度( F=1.754, P=0.182)、阅读错误率( H=6.347, P=0.052)差异均无统计学意义。三焦组近视力维度得分(92±14)和双焦组近视力维度得分(100±11)均高于单焦组(50±42) ( U=-3.139, P=0.005;U=-3.726, P=0.001);三焦组中视力维度得分(100±12)高于双焦组(75±25)和单焦组(25±75) ( U=-2.758, P=0.017;U=-3.145, P=0.002)。三焦组脱镜率维度得分(100±25)和双焦组脱镜率维度得分(100±40)高于单焦组(30±100) ( U=-3.004, P=0.008;U=-3.766, P=0.001)。 结论:多焦点IOL植入患者可获得与单焦点IOL植入患者配戴老花镜时相同的近距离视觉质量;AT Lisa tri.839MP IOL与Tecnis ZMB00 IOL可提供相同的远近视力及近距离阅读能力,但前者中距离视觉质量更佳。  相似文献   

4.
不同焦点人工晶状体植入治疗白内障患者术后视觉效果   总被引:2,自引:2,他引:0  
鲍晓艳 《国际眼科杂志》2016,16(12):2241-2243
目的:探究多焦点和单焦点人工晶状体植入治疗白内障,对比术后患者视觉效果质量的差异及临床价值。方法:选取我院接治的白内障患者65例90眼,根据植入晶状体的不同划分,观察组多焦点人工晶状体的患者32例43眼,对照组单焦点人工晶状体的患者33例47眼。对比术后1、3 mo两组患者远近视力;分析术后3 mo两组患者的对比敏感度数值及问卷调查结果。结果:术后3 mo 时观察组患者裸眼远视力( uncorrected distant visual acuity,UDVA)、矫正远视力( corrected distant visual acuity,CDVA)、裸眼近视力( uncorrected near visual acuity,UNVA)及矫正近视力( corrected near visual acuity, CNVA)均高于对照组,差异有统计学意义(P<0.05);术后3mo,观察组患者有无炫光检测在空间频率3、6、12及18 c/d时的敏感度显著优于对照组患者,差异有统计学意义(P<0.05);术后3mo对两组进行问卷调查研究时发现,两组患者在夜间行动障碍及眩光头晕方面比较上,差异无统计学意义(P>0.05),但在中、近视无需配镜及读书看报不清方面,观察组总体满意度显著高于对照组,差异有统计学意义(P<0.05)。结论:使用多焦点人工晶状体的患者术后远近视力效果更好,对比敏感度上升,整体满意度高,能够较好地满足患者术后的视觉生活需要。  相似文献   

5.
目的:对三焦点、双焦点及连续视程人工晶状体植入术后的单眼视力和动态视力(DVA)进行评估及比较。方法:前瞻性临床研究。选取2020年1月至2021年1月于重庆医科大学附属第一医院眼科行白内障超声乳化摘除联合人工晶状体植入且资料完整的白内障患者65例(81眼)。根据所选择的IOL 类型分为3组:双焦点组33眼,植入Tecnis ZMB00 IOL;三焦点组20眼,植入AT Lisatri.839MP IOL;EDOF组28眼,植入Tecnis ZXR00 IOL。术后3个月分别检测每眼的裸眼静态视力(SVA):包括裸眼远视力(UDVA)、裸眼中视力(UIVA)、裸眼近视力(UNVA)(LogMAR视力)。采用运动视标法检测裸眼DVA(检测速度分别为4、8、12、24fps):包括裸眼动态远视力(UDDVA)、裸眼动态中视力(UIDVA)、裸眼动态近视力(UNVA)(LogMAR视力),并进行评估比较。通过“手抓尺子试验”检测患者反应速度。数据采用卡方检验、方差分析、Kruskal-WallisH检验进行统计分析。结果:3组的总体UDVA、UNVA差异均无统计学意义;3组的总体UIVA差异有统计学意义(H=23.13,P<0.001),进一步两两比较发现EDOF组优于双焦点组(P<0.001);三焦点组优于双焦点组(P=0.016);EDOF 组与三焦点组差异无统计学意义。3组的总体UDDVA在4、8fps时差异均无统计学意义;而在12、24fps时总体差异均有统计学意义(H=10.96,P=0.004;H=11.52,P=0.003),进一步比较发现双焦点组优于三焦点组(H=-16.21,P=0.003;H=-17.98,P=0.004),EDOF组优于三焦点组(H=-12.67,P=0.030;H=-16.48,P=0.009),双焦点组与EDOF组差异无统计学意义。3组的总体UIDVA在8fps 时差异无统计学意义,而在4、12、24fps时差异均有统计学意义(H=8.17~11.36,P<0.05):4、12fps 时,EDOF组优于双焦点组(H=14.61,P=0.013;H=14.52,P=0.009),与三焦点组差异无统计学意义;24fps时,EDOF组优于双焦点组、三焦点组(H=15.31,P=0.008;H=-16.60,P=0.027)。3组的总体UNDVA在4、8、12、24fps时差异均有统计学意义(H=11.25~17.61,P<0.05),且EDOF组均分别优于双焦点组(H=12.71~17.87,P<0.05)和三焦点组(H=-23.04~-15.87,P<0.05),双焦点组与三焦点组差异均无统计学意义(均P>0.05)。结论:在SVA方面,三焦点IOL及EDOFIOL均可获得较好的UDVA、UIVA、UNVA,而双焦点IOL的UIVA较弱。在DVA方面,远距离、低速度时,3种IOL结果相当;但是近距离、高速度时,EDOFIOL的DVA较其余二者更佳。  相似文献   

6.
目的对比区域折射型多焦点人工晶状体(MIOL)SBL-3与非球面单焦点人工晶状体Akreos Adapt AO植入术后短期内患者的客观视觉质量。 方法选取2017年6月至2018年1月在北京大学第一医院眼科诊断为单纯老年性白内障,并行白内障超声乳化吸除联合人工晶状体植入术的患者26例(35只眼)为研究对象。其中,植入SBL-3晶状体有15只眼,植入AO晶状体有20只眼。术后1个月检查SBL-3组及AO组患者术眼的裸眼远视力(UDVA)、裸眼中视力(UIVA)、裸眼近视力(UNVA)、矫正远视力(CDVA)、矫正近视力(CNVA)、最佳矫正远视力下的中视力(DCIVA)及最佳矫正远视力下的近视力(DCNVA),并使用视觉质量分析仪评估两组患者瞳孔直径4 mm与6 mm的全眼、角膜及眼内的总高阶像差、球差及点扩散函数。术后1个月,绘制SBL-3组患者术眼的离焦曲线。两组患者术眼的UDVA、CDVA、CNVA、UIVA、UNVA、DCIVA、DCNVA及视觉质量以均数±标准差( ±s)表示,行非参数Mann-Whimey U检验比较。 结果术后1个月时,SBL-3组及AO组患者术眼的UDVA、CDVA及CNVA差异均无统计学意义(Z=-0.99,0,-1.84;P>0.05);SBL-3组患者术眼的UIVA、UNVA、DCIVA及DCNVA分别为0.32±0.08、0.44±0.18、0.30±0.10及0.33±0.11,均优于AO组的0.25±0.10、0.27±0.09、0.20±0.07及0.21±0.10,差异均有统计学意义(Z=-2.26,-3.13,-1.84,-2.17;P<0.05)。视觉质量评估显示,瞳孔直径为4 mm的两组患者术眼球差的差异无统计学意义(Z=-1.50,-1.04,-0.82;P>0.05);瞳孔直径为6 mm的两组患者术眼球差的差异无统计学意义(Z=-0.12,-1.93,-1.16;P>0.05)。SBL-3组瞳孔直径4 mm与6 mm的全眼总高阶像差分别为0.45±0.12与1.41±0.21,高于AO组的0.26±0.12与0.82±0.13,差异均有统计学意义(Z=-3.45,-3.24;P<0.05)。SBL-3组患者术眼的点扩散函数为0.05±0.02,低于AO组的0.11±0.07,差异有统计学意义(Z=-2.60,P<0.05)。SBL-3组患者术眼的离焦曲线显示波峰出现在0 D处,在-1.0 D至-3.0 D范围内的曲线较平稳,下降不明显;在-3.0 D至-5.0 D范围内的曲线快速下降。 结论Adapt AO晶状体术后客观视觉质量优于SBL-3晶状体,但SBL-3晶状体在中、近视力的应用效果优于Adapt AO晶状体。SBL-3晶状体的离焦曲线波峰出现在0 D处,在-1.0 D至-3.0 D范围内的曲线较平稳,下降不明显。本研究还需扩大样本量并长期观察其效果及安全性。  相似文献   

7.

目的:比较连续视程(Tecnis Symfony)人工晶状体(IOL)和区域折射型(Lentis Comfort LS-313 MF15)IOL植入术后患者的视觉质量。

方法:临床前瞻性研究。收集2021-01/12在我院行白内障超声乳化联合IOL植入术的白内障患者267例(305眼),按植入IOL类型分为Symfony组(A组,160眼)和MF15组(B组,145眼),观察两组患者术后3mo裸眼远视力(uncorrected distance visual acuity, UDVA)(5m)、裸眼中视力(uncorrected intermediate visual acuity, UIVA)(80cm)、裸眼近视力(uncorrected near visual acuity, UNVA)(40cm),离焦曲线,调制传递函数(MTF)和高阶相差(HOAs),包括彗差、球差、三叶草差,进行视觉质量问卷调查(Quality of Vision questionnaire,QoV)。

结果:两组患者术前各参数差异均无统计学意义(P>0.05)。A组和B组UDVA和UNVA差异无统计学意义(P>0.05); A组的UIVA高于B组(P<0.05); A组的MTF值在各个空间频率下均高于B组,差异具有统计学意义(P<0.05); A组的HOAs低于B组(P<0.05); 术后3mo绘制离焦曲线显示0D处两组视力相似,-0.5D~-2.5D处A组视力优于B组,且在-1.0D和-2.0D处差异有统计学意义(P<0.05); A组的Qov分数高于B组(P<0.05); A组出现光晕,星爆等不良视觉干扰现象的频率要高于B组。

结论:MF15和Symfony均提供了稳定的远,近距离视力; 与MF15相比,Symfony IOL具有较好的中距离视力,较高的对比敏感度以及较低的HOAs; 与Symfony相比,MF15人工晶状具有更少的术后不良视觉干扰现象(光晕,星芒等)。  相似文献   


8.
目的:观察三焦点与单焦点人工晶状体对年龄相关性白内障患者术后早期视觉质量的影响。

方法:采用回顾性队列研究设计。纳入2018-06/2021-01在我院白内障科行白内障超声乳化联合人工晶状体植入术的年龄相关性白内障患者119例168眼,按照所植入人工晶状体类型分为三焦点组44例61眼与单焦点组75例107眼。对两组患者术后1mo视力(LogMAR)、视觉质量检查以及明、暗适应条件下对比敏感度检查进行统计学分析。

结果:三焦点组单眼裸眼远视力(UDVA)、裸眼中距离视力(UIVA)、单眼裸眼近视力(UNVA)、最佳矫正远视力(BDVA)、最佳矫正远视下的中距离视力(DIVA)、最佳矫正远视下的近视力(DNVA)均明显优于单焦点组(均P<0.001)。三焦点组在调制传递函数截止频率(MTF cutoff)、客观散射指数(OSI)和斯特尔比值(SR)方面明显优于单焦点组(均P<0.05); 在暗及明适应条件下的18c/d空间频率上,单焦点组对比敏感度明显优于三焦点组(P<0.001)。基于VF/QOF量表分析的调查问卷,三焦点组在日常生活感受评分和脱镜率方面明显优于单焦点组(P<0.05),而眩光发生率二者无差异(P>0.05)。

结论:植入三焦点人工晶状体可为年龄相关性白内障超声乳化术后患者提供全方位良好的视力和视觉质量,满足不同条件下的用眼需求。  相似文献   


9.
目的:研究两种非球面衍射型多焦点人工晶状体(IOL)视网膜成像质量。方法:回顾性队列研究。选取2017-10/2019-10诊断为单纯性白内障,行超声乳化吸除联合IOL植入155例155眼为研究对象,植入非球面衍射双焦点IOL 54例54眼、非球面衍射三焦点IOL 54例54眼、单焦点IOL 47例47眼做对照组。随访术后6mo,双通道视觉质量分析系统测量散射指数(OSI)、调制传递函数截止频率(MTF cut off)、斯特列尔比值(SR)、100%、20%、9%模拟对比度视力(OV);记录术后裸眼远距离(5m)、中距离(80cm)、近距离(40cm)视力及矫正远视力、矫正远视力基础上的中距离视力和近距离视力;利用VF-14量表进行评分。结果:双焦组和三焦组MTF cut off均低于单焦组(P=0.007、0.043),双焦和三焦组无差异(P=0.445)。三组OSI值无差异(F=1.143,P=0.322),三组SR值无差异(F=3.045,P=0.051)。双焦组和三焦组模拟对比度视力无差异(OV 100%:P=0.974;OV 20%:P=0.713;OV 9%:P=0.947),而双焦和三焦组均低于单焦点组(OV 100%:双焦vs单焦P=0.001;三焦vs单焦P=0.012;OV 20%:双焦vs单焦P=0.002;三焦vs单焦P=0.043;OV 9%:双焦vs单焦P=0.011;三焦vs单焦P=0.029)。三组术后裸眼远视力及矫正远视力均无差异(P=0.054、0.180)。双焦组与单焦组裸眼中视力有差异(P=0.010),三焦组与单焦组、双焦组均有差异(P<0.01)。双焦组和三焦组裸眼近视力无差异(P=0.428),双焦组和三焦组与单焦组均有差异(P<0.01)。三组患者远视力矫正基础上中视力有差异(H=67.176,P<0.01),双焦组与单焦组有差异(P<0.01),三焦组与单焦组和双焦组均有差异(P<0.01)。三组远视力矫正基础上近视力均有差异(H=91.292,P<0.01),双焦组和三焦组无差异(P=0.519),双焦组和三焦组与单焦组均有差异(P<0.01)。三组VF-14表评分有差异(H=71.342,P<0.01),双焦组和三焦组评分无差异(P=0.055),双焦组和三焦组与单焦组均有差异(P<0.01)。结论:双通道视觉系统评估三焦点、双焦点衍射型人工晶状体视网膜成像质量无差别;三焦点较双焦点人工晶状体,可提供更佳的中距离视力。  相似文献   

10.

目的:观察并比较AT LISA tri 839MP三焦点人工晶状体及CT SPHERIS 209M单焦点人工晶状体植入术后白内障患者的视力、对比敏感度和视觉质量。

方法:行白内障超声乳化摘除联合人工晶状体植入术的患者52例52眼,其中三焦点组26例26眼,术中植入AT LISA tri 839MP三焦点人工晶状体; 单焦点组26例26眼,术中植入CT SPHERIS 209M单焦点人工晶状体。术后3mo检查患者的裸眼远距离视力(UCDVA)、裸眼中距离视力(UCIVA)、裸眼近距离视力(UCNVA)、最佳矫正远视力(BCDVA)、远视力矫正下的中距离视力(DCIVA)、远视力矫正下的近距离视力(DCNVA),明、暗环境中不同空间频率(3、6、12、18c/d)下的对比敏感度,并进行脱镜率、不良视觉症状和满意度等问卷调查。

结果:术后3mo三焦点组UCIVA、UCNVA、DCIVA和DCNVA、脱镜率及满意度均优于单焦点组(P<0.05)。在暗环境中的18c/d空间频率,单焦点组的对比敏感度优于三焦点组(P=0.041)。两组均有轻度眩光和光晕不适主诉(P=0.668)。

结论:AT LISA tri 839MP三焦点人工晶状体较CT SPHERIS 209M单焦点人工晶状体为患者提供了更好的中、近视力,脱镜率和满意度均高于单焦点人工晶状体。  相似文献   


11.
Purpose: To determine whether bilateral implantation of an aspheric apodized diffractive multifocal intraocular lens (IOL) with +3.00 diopters (D) results in optical adverse effects compared with an aspheric monofocal IOL. Methods: In a prospective, randomized study of 204 eyes (102 patients) with bilateral implantation of an AcrySof ReSTOR SN6AD1 IOL or an AcrySof IQ SN60WF IOL, binocular uncorrected (UDVA) and corrected distance visual acuities (CDVA), uncorrected (UIVA) and distance‐corrected intermediate visual acuities (DCIVA), uncorrected (UNVA) and distance‐corrected near visual acuities (DCNVA), defocus curve, intraocular straylight, wavefront aberrations, modulation transfer functions (MTF) and patient questionnaires were evaluated postoperatively. Results: Both groups resulted in similar UDVA and CDVA (p > 0.05), whereas the multifocal IOL group performed significantly better UIVA and DCIVA at 50, 60 cm, and better UNVA and DCNVA at 40 cm (p ≤ 0.001). Higher intraocular straylight was obtained in the multifocal IOL group (p = 0.016). Total, higher‐order, spherical and coma aberrations performed similar in both groups (p > 0.05). MTF was lower in the multifocal IOL group than in the monofocal IOL group with 3.0‐mm pupils at 5 and 10 cycles per degree (cpd). Although patients in the multifocal IOL group complained more glare/flare, problems with night vision, and halos, they reported excellent spectacle independence, and high satisfaction. Conclusions: Compared with the AcrySof IQ IOL, the ReSTOR SN6AD1 IOL provided excellent visual outcomes, satisfactory spectacle independence without compromising wavefront aberrations; however, optical adverse effects with respect to higher intraocular straylight and lower MTF at lower spatial frequency were demonstrated.  相似文献   

12.
目的 比较双眼植入ReSTOR+3D非球面多焦点人工晶状体(MIOL)与传统球面单焦点人工晶状体(SIOL)后全程视力和立体视觉情况.方法 前瞻性临床研究.对2009年5月至2010年6月在上海公利医院眼科治疗的病人18例(36只眼)植入ReSTOR+3DMIOL(SN6ADI),20例(40只眼)植入传统球面SIOL(SNt0AT).以术后第二眼为标准随访3个月.测两组的远、中、近视力及近立体视锐度,进行相应统计学分析.结果 术后裸眼及最佳远、近矫正视力两组无明显差异(t值分别为1.14、1.74、0.99,P>0.05),在25cm、30cm、33cm、40cm、50cm、60cm、70cm近中距离上,MIOL组远视力矫正下近视力均优于SIOL组(t值分别为14.02、20.28、24.52、32.74、21.91、11.66、9.76,P<0.01).MIOL组裸眼近立体视锐度优于SIOL组(P<0.05).双眼矫正近视力后,两组的立体视觉差异无统计学意义(X2=64.97 P>0.05).结论 ReSTOR+3D多焦点IOL较单焦点IOL可提供更好的近、中视力和裸眼近立体锐度,实现了很高地脱镜率,良好地全程视力使其拥有广泛的应用价值.
Abstract:
Objective To compare visual acuity from far to near and stereoscopic vision in patients who underwent bilateral implantation of aspheric diffractive multifocal intraocular lens (IOLs)with monofocal IOLs. Methods This prospective study comprised patients having implantation of an aspheric diffractive multifocal ReSTOR SN6AD1 IOL with a C3.0 D add (SN6AD1) or a monofocal IOL (SN60AT). Visual acuity from far to near distances and stereoscopic vision were evaluated 3months postoperatively. Results Multifocal IOL group comprised 36 eyes of 18 patients. Monofocal IOL group comprised 40 eyes of 20 patients. The differences between groups of uncorrected and corrected distance visual acuity and corrected near visual acuity had not statistically significant (P>0.05).The mean distance-corrected visual acuity at 25 cm, 30 cm, 33 cm, 40 cm, 50 cm, 60 cm, 70 cm were better in the multifocal group than in the monofocal group (P<0.01). The near stereoscopic vision. in the multifocal group were better than in the monofocal group (P<0.01). When near corrected,there were no significant difference between the stereoscopic vision for the multifocal and monofocal groups (P>0.05). Conclusions The diffractive multifocal IOL with a low add power provides significantly better intermediate, near visual acuity than the monofocal IOL. When near uncorrected, the multifocal group has better stereoscopic vision. Spectacle independence is higher with the multifocal intraocular lens.  相似文献   

13.
ObjectivesTo compare the dynamic visual acuity (DVA) following implantation of trifocal with monofocal intraocular lenses (IOL) and using a novel test system.MethodsThe present research was a retrospective, multicenter clinical study. Two hundred and ten eyes of 149 patients that underwent cataract phacoemulsification and IOL implantation were enrolled. One hundred and ten eyes of patients received trifocal (AT LISA tri839MP, Carl Zeiss Meditec, Germany) and 100 eyes received monofocal (Tecnis ZCB00, Abbott, United States) lenses and were evaluated 3 months after implantation. Outcome measures included monocular uncorrected distance (UDVA), intermediate (UIVA) and near (UNVA) visual acuity and best corrected distance visual acuity (BCDVA; logMAR units); contrast sensitivity under photopic, mesopic, with glare conditions; and dynamic visual acuity using a self-developed system.ResultsThere was no statistically significant difference in baseline characteristics between groups. Monocular UDVA, UIVA, and UNVA were significantly better (all p < 0.001) in the trifocal IOL group, but not BCDVA. The trifocal IOL group showed better contrast sensitivity under photopic, mesopic, with or without glare conditions (p < 0.05) and statistically significantly better dynamic vision at 15, 30, 60, and 90 degrees per second (dps) compared with the monofocal group (all p < 0.001). The strength of positive association only between UIVA and dynamic visual acuity increased as the velocity increased, but not UDVA or UNVA.ConclusionsDiffractive trifocal IOL provides better postoperative full range vision acuity, contrast sensitivity, and dynamic vision compared with monofocal IOLs. And intermediate visual acuity is increasingly associated with DVA as the velocity increasing.Subject terms: Quality of life, Outcomes research  相似文献   

14.
目的比较非对称区域折射型多焦点人工晶状体(IOL)与衍射型三焦点IOL治疗年龄相关性白内障的疗效。 方法回顾性研究。收集2016年11月至2018年6月于成都爱尔眼科医院白内障中心行超声乳化白内障吸除联合IOL植入术57例(57只眼)患者的病历资料。其中,男性28例(28只眼),女性29例(29只眼);年龄50~76岁,平均年龄(63.3±5.5)岁。按照植入IOL的类型将患者分为区域折射组和衍射三焦组。检查并记录两组患者术前与术后3个月的术眼屈光度、裸眼远距离视力(UDVA)、裸眼中距离视力(UIVA)、裸眼近距离视力(UNVA)、最佳矫正远视力(BCDVA)、客观散射指数(OSI)、调制传递函数截止空间频率(MTF cutoff)、斯特列尔比值(SR)以及对比度视力。根据中文版VF-14视功能指数量表对上述指标进行评分,并对患者进行问卷调查。两组患者患眼的眼轴长度、角膜散光、术前UDVA、术前BCDVA、术后OSI、MTF cutoff、SR及中文版VF-14视功能指数量表评分等指标采用均数±标准差表示,并以独立样本t检验进行比较。UDVA、UIVA、UNVA、BCDVA及对比度视力采用中位数和四分位数间距表示。采用Mann-Whitney U检验,比较两组患者术后3个月术眼的UDVA、UIVA、UNVA、BCDVA以及对比度视力。 结果区域折射组和衍射三焦组患者的术后球镜屈光度分别为-0.75 D~+0.50 D和-0.50 D~+1.00 D。两组患者球镜屈光度位于-0.50 D~+0.50 D区间者占比的比较,差异无统计学意义(χ2=0.000,P>0.05)。两组患者术后柱镜屈光度分别为0.00 D~-0.75 D和0.00 D~-1.00 D。两组患者柱镜屈光度位于-0.75 D~-1.00 D者占比的比较,差异无统计学意义(χ2=0.459,P>0.05)。区域折射组患者术后的UDVA、UIVA、UNVA及BCDVA分别为0.10(0.00,0.10)、0.20(0.20,0.20)、0.20(0.10,0.20)及0.00(0.00,0.10);衍射三焦组患者术后分别为0.05(0.00,0.10)、0.20(0.10,0.20)、0.10(0.10,0.20)及0.00(0.00,0.05)。经Mann-Whitney U检验,两组患者术后UDVA、UNVA和BCDVA的比较,差异无统计学意义(Z=-0.169,-1.265,-1.410;P>0.05);UIVA的比较,差异有统计学意义(Z=-2.708,P<0.05)。区域折射组患者术后的OSI、MTF cutoff及SR分别为(1.9±0.7)、(24.755±7.751)c/deg和(0.126±0.029);衍射三焦组患者术后分别为(1.6±0.7)、(35.813±9.984)c/deg和(0.195±0.083)。经t检验,两组患者MTF cutoff和SR的比较,差异有统计学意义(t=-5.419,-4.822;P<0.05);OSI的比较,差异无统计学意义(t=1.959,P>0.05)。区域折射组患者术后在100%、20%和9%对比度下的对比度视力分别为0.70(0.60,0.90)、0.50(0.40,0.60)和0.30 (0.20,0.30);衍射三焦组分别为1.20(0.95,1.50)、0.70(0.60,0.90)和0.50(0.30,0.70)。经Mann-Whitney U检验,两组患者对比度视力的比较,差异有统计学意义(Z=-4.882,-4.829,-3.676;P<0.05)。区域折射组与衍射三焦组的中文版VF-14视功能指数量表评分分别为(94.39±4.74)分与(96.86±3.63)分,两者比较的差异无统计学意义(t=-0.075,P>0.05)。区域折射组与衍射三焦组眩光的发生率分别为10.7%与6.9%。两组近脱镜率和眩光发生率的比较,差异无统计学意义(χ2=0.181,0.002;P>0.05)。区域折射组与衍射三焦组轻度光晕的发生率分别为3.57%与27.59%,差异有统计学意义(χ2=4.505,P<0.05)。 结论两种老视矫正型IOL均能为年龄相关性白内障患者提供较好的全程视力,术后患眼屈光度可预测性好,而衍射型三焦点IOL客观视网膜成像质量的评估方面较区域折射型多焦点IOL略好。  相似文献   

15.
目的 观察高度近视患者植入带中心孔植入式透镜(implantable collamer lens,ICL)后的临床疗效和视觉相关的生活质量。方法 前瞻性病例研究。选取我院诊断为高度近视,并植入V4c-ICL患者25例(50眼)为研究对象。术前及术后1个月、3个月、6个月分别检查患者屈光状态,裸眼远、中、近视力,最佳矫正远视力,远视力矫正下中、近视力,双眼视力,眼压,角膜内皮细胞密度(corneal endothelial cell density,ECD),并进行国家眼科研究所视功能问卷-25(national eye institute-visual function questionnaire,NEI-VFQ-25)调查及评分。结果 高度近视患者植入V4c-ICL后不同时间球镜、柱镜、等效球镜(spherical equivalent,SE)度较术前均明显降低(F=884.35、17.15、810.25,均为P<0.05);术后不同时间裸眼远、中、近视力,最佳矫正远视力,远视力矫正下中、近视力和双眼视力较术前均明显改善(F=604.47、878.13、713.92、22.25、5.33、6.90、16.51,均为P<0.05)。术前及术后随访期间眼压、ECD无明显变化(F=0.07、1.53,均为P>0.05);术后NEI-VFQ-25评分较术前明显提高(F=21.76,P<0.05)。结论 高度近视患者植入V4c-ICL后屈光不正得到矫正、短期内屈光稳定,随访期间远、中、近视力明显提高,视觉相关的生活质量明显改善。V4c-ICL植入术治疗高度近视安全、有效。  相似文献   

16.
目的 比较双眼行超声乳化白内障吸除联合植入ReSTOR阶梯渐进衍射型多焦点人工晶状体(MIOL)和单焦点人工晶状体(SIOL)的术后视觉质量.方法 回顾性比较性系列病例研究.回顾性分析25例(50只眼)双眼行超声乳化白内障吸除联合ReSTOR MIOL植入(多焦点组)和28例(56只眼)双眼行超声乳化白内障吸除术联合Natural SIOL植入(单焦点组)的年龄相关性白内障患者的临床资料.观察术后3个月时裸眼远、近视力,最佳矫正远、近视力,远矫正状态下近视力、对比敏感度和眩光敏感度,视觉干扰以及脱镜率.两组间计量资料采用t检验;两组间计数资料采用X2检验.结果 术后3个月,多焦点组94%(47/50)和单焦点组96%(54/56)患眼术后裸眼远视力≥0.6(X2=0.347,P>0.05);多焦点组88%(44/50)和单焦点组13%(7/56)患眼裸眼近视力等于或好于J3(X2=60.315,P<0.01);多焦点组90%(45/50)和单焦点组11%(6/56)患眼远矫正状态下裸眼近视力等于或好于J3(X2=66.515,P<0.01);两组各空间频段的对比敏感度和眩光敏感度差异均无统计学意义(P>0.05);多焦点组12%(3/25)和单焦点组7%(2/28)患者术后出现轻度以上的眩光感(X2=0.365,P>0.05);多焦点组8%(2/25)和单焦点组4%(1/28)患者术后出现轻度以上的光晕(X2=0.485,P>0.05);两组均有96%(24/25、27/28)的患者术后视远完全脱镜(X2=0.007,P>0.05);多焦点组80%(20/25)和单焦点组11%(3/28)患者术后视近完全脱镜(X2=25.811,P<0.01).结论 ReSTOR阶梯渐进衍射型MIOL能同时提供良好的远、近视力,减少了患者术后对眼镜的依赖,具有较好的视觉质量.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号