首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Poly(lactic-co-glycolic acid) (PLGA) meshes loaded with retinoic acid (RA) were prepared by applying the electrospinning technique. The purpose of the present work was to combine the biological effects of RA and the advantages of electrospun meshes to enhancing the mass transfer features of controlled release systems and cell interaction with polymeric scaffolds. The processing conditions for the fabrication of three-dimensional meshes were optimized by studying their influence on mesh morphology. Tensile testing showed that RA loading influenced the meshes’ mechanical properties by increasing their strength and rigidity. Moreover, the drug release and degradation profiles of the electrospun systems were compared to analogous RA-loaded PLGA films prepared by solvent casting. The results of this study highlight that the electrospun meshes preserved their fibrous structure after 4 months under in vitro physiological conditions and showed a sustained controlled release of the loaded agent in comparison to that observed for cast films. The bioactivity of the loaded RA was investigated on murine preosteoblasts cells by evaluating its influence on cell proliferation and morphology.  相似文献   

2.
Wet spun microfibers have great potential for the design of multifunctional controlled release scaffolds. Understanding aspects of drug delivery and mechanical strength, specific to protein molecular weight, may aid in the optimization and development of wet spun fiber platforms. This study investigated the intrinsic material properties and release kinetics of poly(l-lactic acid) (PLLA) and poly(lactic-co-glycolic acid) (PLGA) wet spun microfibers encapsulating proteins with varying molecular weights. A cryogenic emulsion technique developed in our laboratory was used to encapsulate insulin (5.8 kDa), lysozyme (14.3 kDa) and bovine serum albumin (BSA, 66.0 kDa) within wet spun microfibers (~100 μm). Protein loading was found to significantly influence mechanical strength and drug release kinetics of PLGA and PLLA microfibers in a molecular-weight-dependent manner. BSA encapsulation resulted in the most significant decrease in strength and ductility for both PLGA and PLLA microfibers. Interestingly, BSA-loaded PLGA microfibers had a twofold increase (8 ± 2 MPa to 16 ± 1 MPa) in tensile strength and a fourfold increase (3 ± 1% to 12 ± 6%) in elongation until failure in comparison to PLLA microfibers. PLGA and PLLA microfibers exhibited prolonged protein release up to 63 days in vitro. Further analysis with the Korsmeyer–Peppas kinetic model determined that the mechanism of protein release was dependent on Fickian diffusion. These results emphasize the critical role protein molecular weight has on the properties of wet spun filaments, highlighting the importance of designing small molecular analogues to replace growth factors with large molecular weights.  相似文献   

3.
Enrichment of calcium phosphate (CaP) bone substitutes with poly(lactic-co-glycolic acid) (PLGA) microspheres to create porosity overcomes the problem of poor CaP degradation. The degradation of CaP–PLGA composites can be customized by changing the physical and chemical properties of PLGA and/or CaP. However, the effect of the size of dense (solid rather than hollow) PLGA microspheres in CaP has not previously been described. The present study aimed at determining the effect of different dense (i.e. solid) PLGA microsphere sizes (small (S) ~20 μm vs. large (L) ~130 μm) and of CaP composition (CaP with either anhydrous dicalcium phosphate (DCP) or calcium sulphate dihydrate (CSD)) on CaP scaffold biodegradability and subsequent bone in-growth. To this end mandibular defects in minipigs were filled with pre-set CaP–PLGA implants, with autologous bone being used as a control. After 4 weeks the autologous bone group outperformed all CaP–PLGA groups in terms of the amount of bone present at the defect site. On the other hand, at 12 weeks substantial bone formation was observed for all CaP–PLGA groups (ranging from 47 ± 25% to 62 ± 15%), showing equal amounts of bone compared with the autologous bone group (82 ± 9%), except for CaP with DCP and large PLGA microspheres (47 ± 25%). It was concluded that in the current study design the difference in PLGA microsphere size and CaP composition led to similar results with respect to scaffold degradation and subsequent bone in-growth. Further, after 12 weeks all CaP–PLGA composites proved to be effective for bone substitution.  相似文献   

4.
Biomaterials made of biodegradable poly(α-hydroxyesters) such as poly(lactide-co-glycolide) (PLGA) are known to decrease the pH in the vicinity of the implants. Bioactive glass (BG) is being investigated as a counteracting agent buffering the acidic degradation products. However, in dentistry the question arises whether an antibacterial effect is rather obtained from pure PLGA or from BG/PLGA composites, as BG has been proved to be antimicrobial. In the present study the antimicrobial properties of electrospun PLGA and BG45S5/PLGA fibres were investigated using human oral bacteria (specified with mass spectrometry) incubated for up to 24 h. BG45S5 nanoparticles were prepared by flame spray synthesis. The change in colony-forming units (CFU) of the bacteria was correlated with the pH of the medium during incubation. The morphology and structure of the scaffolds as well as the appearance of the bacteria were followed bymicroscopy. Additionally, we studied if the presence of BG45S5 had an influence on the degradation speed of the polymer. Finally, it turned out that the pH increase induced by the presence of BG45S5 in the scaffold did not last long enough to show a reduction in CFU. On the contrary, pure PLGA demonstrated antibacterial properties that should be taken into consideration when designing biomaterials for dental applications.  相似文献   

5.
Poly(lactide-co-glycolide)/hydroxyapatite(50/50) (PLGA/HA(50/50)) composite microspheres were fabricated and treated with a mixture of 0.25 M NaOH aqueous solution and ethanol (v/v = 1/1) at 37 °C. The properties of untreated and treated PLGA/HA(50/50) composite microspheres were determined and compared. The results showed that the surface roughness, HA content and hydrophilicity of the treated PLGA/HA(50/50) composite microspheres increased with treatment time. However, the treatment time should be kept within 2 h in order to maintain the shape of the PLGA/HA(50/50) microspheres. At the same time, a degradation study showed that both the untreated and treated microspheres degraded gradually with time, with the treated microspheres degrading faster in the first 4 weeks. The rhBMP-2-loaded PLGA/HA(50/50) composite microspheres were prepared by solution dipping treated PLGA/HA(50/50) composite microspheres. Mouse OCT-1 osteoblast-like cells were cultured on the untreated, treated and rhBMP-2-loaded PLGA/HA(50/50) composite microspheres and the cell affinity of the various microspheres was assessed and compared. It was found that the surface-treated PLGA/HA(50/50) composite microspheres clearly promoted osteoblast attachment, proliferation and alkaline phosphatase activity. It was considered that the hydrophilicity, osteoconductivity and surface roughness were increased by the increase in the HA component, which facilitated cell growth. Moreover, the rhBMP-2 loaded on the treated PLGA/HA(50/50) composite microspheres could be slowly released and further enhanced osteoblast differentiation. The good cell affinity and enhanced osteogenic potential of the rhBMP-2-loaded PLGA/HA composite microspheres indicate that they could be used as an injectable scaffold.  相似文献   

6.
Bioactive glasses (BGs) are known for their unique ability to bond to living bone. Consequently, the incorporation of BGs into calcium phosphate cement (CPC) was hypothesized to be a feasible approach to improve the biological performance of CPC. Previously, it has been demonstrated that BGs can successfully be introduced into CPC, with or without poly(d,l-lactic-co-glycolic) acid (PLGA) microparticles. Although an in vitro physicochemical study on the introduction of BG into CPC was encouraging, the biocompatibility and in vivo bone response to these formulations are still unknown. Therefore, the present study aimed to evaluate the in vivo performance of BG supplemented CPC, either pure or supplemented with PLGA microparticles, via both ectopic and orthotopic implantation models in rats. Pre-set scaffolds in four different formulations (1: CPC; 2: CPC/BG; 3: CPC/PLGA; and 4: CPC/PLGA/BG) were implanted subcutaneously and into femoral condyle defects of rats for 2 and 6 weeks. Upon ectopic implantation, incorporation of BG into CPC improved the soft tissue response by improving capsule and interface quality. Additionally, the incorporation of BG into CPC and CPC/PLGA showed 1.8- and 4.7-fold higher degradation and 2.2- and 1.3-fold higher bone formation in a femoral condyle defect in rats compared to pure CPC and CPC/PLGA, respectively. Consequently, these results highlight the potential of BG to be used as an additive to CPC to improve the biological performance for bone regeneration applications. Nevertheless, further confirmation is necessary regarding long-term in vivo studies, which also have to be performed under compromised wound-healing conditions.  相似文献   

7.
How to accurately control the microstructure of bioactive inorganic/organic nanocomposites still remains a significant challenge, which is of great importance in influencing their mechanical strength and biological properties. In this study, using a combined method of electrospinning and hot press processing, calcium silicate hydrate (CSH) nanowire/poly(l-lactide) (PLLA) nanocomposites with controllable microstructures and tailored mechanical properties were successfully prepared as potential bone graft substitutes. The electrospun hybrid nanofibers with various degrees of alignment were stacked together in a predetermined manner and hot pressed into hierarchically structured nanocomposites. The relationship between the microstructure and mechanical properties of the as-prepared nanocomposites were systematically evaluated. The results showed that CSH nanowires in a PLLA matrix were able to be controlled from completely randomly oriented to uniaxially aligned, and then hierarchically organized with different interlayer angles, leading to corresponding nanocomposites with improved mechanical properties and varied anisotropies. It was also found that the bending strength of nanocomposites with 5 wt.% CSH nanowires (130 MPa) was significantly higher than that of pure PLLA (86 MPa) and other composites. The addition of CSH nanowires greatly enhanced the hydrophilicity and apatite-forming ability of PLLA films, as well as the attachment and proliferation of bone marrow stromal cells. The study suggested that a combination of electrospinning and hot pressing is a viable means to control the microstructure and mechanical properties, and improve the mineralization ability and cellular responses, of CSH/PLLA nanocomposites for potential bone repair applications.  相似文献   

8.
Despite the excellent bioactivity of hydroxyapatite (HA) ceramics, poor mechanical strength has limited the applications of these materials primarily to coatings and other non-load-bearing areas as bone grafts. Using synthesized HA nanopowder, dense compacts with grain sizes in the nanometer to micrometer range were processed via microwave sintering between 1000 and 1150 °C for 20 min. Here we demonstrate that the mechanical properties, such as compressive strength, hardness and indentation fracture toughness, of HA compacts increased with a decrease in grain size. HA with 168 ± 86 nm grain size showed the highest compressive strength of 395 ± 42 MPa, hardness of 8.4 ± 0.4 GPa and indentation fracture toughness of 1.9 ± 0.2 MPa m1/2. To study the in vitro biological properties, HA compacts with grain size between 168 nm and 1.16 μm were assessed for in vitro bone cell–material interactions with human osteoblast cell line. Vinculin protein expression for cell attachment and bone cell proliferation using MTT assay showed that surfaces with finer grains provided better bone cell–material interactions than coarse-grained samples. Our results indicate simultaneous improvements in mechanical and biological properties in microwave sintered HA compacts with nanoscale grain size.  相似文献   

9.
Wu C  Zhang Y  Zhou Y  Fan W  Xiao Y 《Acta biomaterialia》2011,7(5):2229-2236
Mesoporous bioactive glass (MBG) is a new class of biomaterials with a well-ordered nanochannel structure, whose in vitro bioactivity is far superior than that of non-mesoporous bioactive glass (BG); the material's in vivo osteogenic properties are, however, yet to be assessed. Porous silk scaffolds have been used for bone tissue engineering, but this material's osteoconductivity is far from optimal. The aims of this study were to incorporate MBG into silk scaffolds in order to improve their osteoconductivity and then to compare the effect of MBG and BG on the in vivo osteogenesis of silk scaffolds. MBG/silk and BG/silk scaffolds with a highly porous structure were prepared by a freeze-drying method. The mechanical strength, in vitro apatite mineralization, silicon ion release and pH stability of the composite scaffolds were assessed. The scaffolds were implanted into calvarial defects in SCID mice and the degree of in vivo osteogenesis was evaluated by microcomputed tomography (μCT), hematoxylin and eosin (H&E) and immunohistochemistry (type I collagen) analyses. The results showed that MBG/silk scaffolds have better physiochemical properties (mechanical strength, in vitro apatite mineralization, Si ion release and pH stability) compared to BG/silk scaffolds. MBG and BG both improved the in vivo osteogenesis of silk scaffolds. μCT and H&E analyses showed that MBG/silk scaffolds induced a slightly higher rate of new bone formation in the defects than did BG/silk scaffolds and immunohistochemical analysis showed greater synthesis of type I collagen in MBG/silk scaffolds compared to BG/silk scaffolds.  相似文献   

10.
《Acta biomaterialia》2014,10(7):3295-3306
Polymer biomaterials have been widely used for bone replacement/regeneration because of their unique mechanical properties and workability. Their inherent low bioactivity makes them lack osseointegration with host bone tissue. For this reason, bioactive inorganic particles have been always incorporated into the matrix of polymers to improve their bioactivity. However, mixing inorganic particles with polymers always results in inhomogeneity of particle distribution in polymer matrix with limited bioactivity. This study sets out to apply the pulsed laser deposition (PLD) technique to prepare uniform akermanite (Ca2MgSi2O7, AKT) glass nanocoatings on the surface of two polymers (non-degradable polysulfone (PSU) and degradable polylactic acid (PDLLA)) in order to improve their surface osteogenic and angiogenic activity. The results show that a uniform nanolayer composed of amorphous AKT particles (∼30 nm) of thickness 130 nm forms on the surface of both PSU and PDLLA films with the PLD technique. The prepared AKT-PSU and AKT-PDLLA films significantly improved the surface roughness, hydrophilicity, hardness and apatite mineralization, compared with pure PSU and PDLLA, respectively. The prepared AKT nanocoatings distinctively enhance the alkaline phosphate (ALP) activity and bone-related gene expression (ALP, OCN, OPN and Col I) of bone-forming cells on both PSU and PDLLA films. Furthermore, AKT nanocoatings on two polymers improve the attachment, proliferation, VEGF secretion and expression of proangiogenic factors and their receptors of human umbilical vein endothelial cells (HUVEC). The results suggest that PLD-prepared bioceramic nanocoatings are very useful for enhancing the physicochemical, osteogenic and angiogenic properties of both degradable and non-degradable polymers for application in bone replacement/regeneration.  相似文献   

11.
《Acta biomaterialia》2014,10(5):2333-2340
In this study the loss of mechanical properties and the interface strength of coated AZ31B magnesium alloy (a magnesium–aluminum alloy) screws with surrounding host tissues were investigated and compared with non-coated AZ31B, degradable polymer and biostable titanium alloy screws in a rabbit animal model after 1, 4, 12 and 21 weeks of implantation. The interface strength was evaluated in terms of the extraction torque required to back out the screws. The loss of mechanical properties over time was indicated by one-point bending load loss of the screws after these were extracted at different times. AZ31B samples with a silicon-containing coating had a decreased degradation rate and improved biological properties. The extraction torque of Ti6Al4V, poly-l-lactide (PLLA) and coated AZ31B increased significantly from 1 week to 4 weeks post-implantation, indicating a rapid osteosynthesis process over 3 weeks. The extraction torque of coated AZ31B increased with implantation time, and was higher than that of PLLA after 4 weeks of implantation, equalling that of Ti6Al4V at 12 weeks and was higher at 21 weeks. The bending loads of non-coated AZ31B and PLLA screws degraded sharply after implantation, and that of coated AZ31B degraded more slowly. The biodegradation mechanism, the coating to control the degradation rate and the bioactivity of magnesium alloys influencing the mechanical properties loss over time and bone–implant interface strength are discussed in this study and it is concluded that a suitable degradation rate will result in an improvement in the mechanical performance of magnesium alloys, making them more suitable for clinical application.  相似文献   

12.
Strontium-containing hydroxyapatite/polyetheretherketone (Sr-HA/PEEK) composites were developed as alternative materials for load-bearing orthopaedic applications. The amount of strontium-containing hydroxyapatite (Sr-HA) incorporated into polyetheretherketone (PEEK) polymer matrix ranged from 15 to 30 vol% and the composites were successfully fabricated by compression molding technique. This study presents the mechanical properties and in vitro human osteoblast-like cell (MG-63) response of the composite material developed. The bending modulus and strength of Sr-HA/PEEK composites were tailored to mimic human cortical bone. PEEK reinforced with 25 and 30 vol% Sr-HA exhibited bending modulus of 9.6 and 10.6 GPa, respectively; alternatively, the bending strengths of the composites were 93.8 and 89.1 MPa, respectively. Based on the qualitative comparison of apatite formation in SBF and quantitative measurement of MG-63-mediated mineralization in vitro, the Sr-HA/PEEK composite was proven to outperform HA/PEEK in providing bioactivity. However, no difference was found in the trend of cell proliferation and alkaline phosphatase activity between different composites. Strontium, in the form of strontium-containing hydroxyapatite (Sr-HA), was confirmed to enhance bioactivity in the PEEK composites.  相似文献   

13.
Novel multi-functional P(3HB) microsphere/45S5 Bioglass®-based composite scaffolds exhibiting potential for drug delivery were developed for bone tissue engineering. 45S5 Bioglass®-based glass–ceramic scaffolds of high interconnected porosity produced using the foam-replication technique were coated with biodegradable microspheres (size < 2 μm) made from poly(3-hydroxybutyrate), P(3HB), produced using Bacillus cereus SPV. A solid-in-oil-in-water emulsion solvent extraction/evaporation technique was used to produce these P(3HB) microspheres. A simple slurry-dipping method, using a 1 wt.% suspension of P(3HB) microspheres in water, dispersed by an ultrasonic bath, was used to coat the scaffold, producing a uniform microsphere coating throughout the three-dimensional scaffold structure. Compressive strength tests confirmed that the microsphere coating slightly enhanced the scaffold mechanical strength. It was also confirmed that the microsphere coating did not inhibit the bioactivity of the scaffold when immersed in simulated body fluid (SBF) for up to 4 weeks. The hydroxyapatite (HA) growth rate on P(3HB) microsphere-coated 45S5 Bioglass® composite scaffolds was very similar to that on the uncoated control sample, qualitatively indicating similar bioactivity. However, the surface topography of the HA surface layer was affected as shown by results obtained from white light interferometry. The roughness of the surface was much higher for the P(3HB) microsphere-coated scaffolds than for the uncoated samples, after 7 days in SBF. This feature would facilitate cell attachment and proliferation. Finally, gentamycin was successfully encapsulated into the P(3HB) microspheres to demonstrate the drug delivery capability of the scaffolds. Gentamycin release kinetics was determined using liquid chromatography–mass spectrometry. The release of the drug from the coated composite scaffolds was slow and controlled when compared to the observed fast and relatively uncontrolled drug release from the bone scaffold (without microsphere coating). Thus, this unique multifunctional bioactive composite scaffold has the potential to enhance cell attachment and to provide controlled delivery of relevant drugs for bone tissue engineering.  相似文献   

14.
Currently, the most severe limitation to applying RNA interference technology is delivery, including localizing the molecules to a specific site of interest to target a specific cell population and sustaining the presentation of these molecules for a controlled period of time. In this study, we engineered a functionalized, biodegradable system created by covalent incorporation of cationic linear polyethyleneimine (LPEI) into photocrosslinked dextran (DEX) hydrogels through a biodegradable ester linkage. The key innovation of this system is that control over the sustained release of short interference RNA (siRNA) was achieved, as LPEI could electrostatically interact with siRNA to maintain siRNA within the hydrogels and degradation of the covalent ester linkages between the LPEI and the hydrogels led to tunable release of LPEI/siRNA complexes over time. The covalent conjugation of LPEI did not affect the swelling or degradation properties of the hydrogels, and the addition of siRNA and LPEI had minimal effect on their mechanical properties. These hydrogels exhibited low cytotoxicity against human embryonic kidney 293 cells (HEK293). The release profiles could be tailored by varying DEX (8 and 12% w/w) and LPEI (0, 5, 10 μg/100 μl gel) concentrations with nearly 100% cumulative release achieved at day 9 (8% w/w gel) and day 17 (12% w/w gel). The released siRNA exhibited high bioactivity with cells surrounding and inside the hydrogels over an extended time period. This controllable and sustained siRNA delivery hydrogel system that permits tailored siRNA release profiles may be valuable to guide cell fate for regenerative medicine and other therapeutic applications such as cancer treatment.  相似文献   

15.
In this study, we report a hybrid organic–inorganic TEOS–MTES (tetraethylorthosilicate–methyltriethoxysilane) sol–gel-made coating as a potential solution to improve the in vivo performance of AISI 316L stainless steel, which is used as permanent bone implant material. These coatings act as barriers for ion migration, promoting the bioactivity of the implant surface. The addition of SiO2 colloidal particles to the TEOS–MTES sol (10 or 30 mol.%) leads to thicker films and also acts as a film reinforcement. Also, the addition of bioactive glass–ceramic particles is considered responsible for enhancing osseointegration. In vitro assays for bioactivity in simulated body fluid showed the presence of crystalline hydroxyapatite (HA) crystals on the surface of the double coating with 10 mol.% SiO2 samples on stainless steel after 30 days of immersion. The HA crystal lattice parameters are slightly different from stoichiometric HA. In vivo implantation experiments were carried out in a rat model to observe the osteointegration of the coated implants. The coatings promote the development of newly formed bone in the periphery of the implant, in both the remodellation zone and the marrow zone. The quality of the newly formed bone was assessed for mechanical and structural integrity by nanoindentation and small-angle X-ray scattering experiments. The different amount of colloidal silica present in the inner layer of the coating slightly affects the material quality of the newly formed bone but the nanoindentation results reveal that the lower amount of silica in the coating leads to mechanical properties similar to cortical bone.  相似文献   

16.
The physiochemical characteristics of a material with in vivo applications are critical for the clinical success of the implant and regulate both cellular adhesion and differentiated cellular function. Topographical modification of an orthopaedic implant may be a viable method to guide tissue integration and has been shown in vitro to dramatically influence osteogenesis, inhibit bone resorption and regulate integrin mediated cell adhesion. Integrins function as force dependant mechanotransducers, acting via the actin cytoskeleton to translate tension applied at the tissue level to changes in cellular function via intricate signalling pathways. In particular the ERK/MAPK signalling cascade is a known regulator of osteospecific differentiation and function. Here we investigate the effects of nanoscale pits and grooves on focal adhesion formation in human osteoblasts (HOBs) and the ERK/MAPK signalling pathway in mesenchymal populations. Nanopit arrays disrupted adhesion formation and cellular spreading in HOBs and impaired osteospecific differentiation in skeletal stem cells. HOBs cultured on 10 μm wide groove/ridge arrays formed significantly less focal adhesions than cells cultured on planar substrates and displayed negligible differentiation along the osteospecific lineage, undergoing up-regulations in the expression of adipospecific genes. Conversely, osteospecific function was correlated to increased integrin mediated adhesion formation and cellular spreading as noted in HOBS cultured on 100 μm wide groove arrays. Here osteospecific differentiation and function was linked to focal adhesion growth and FAK mediated activation of the ERK/MAPK signalling pathway in mesenchymal populations.  相似文献   

17.
During the past two decades, research on ceramic scaffolds for bone regeneration has progressed rapidly; however, currently available porous scaffolds remain unsuitable for load-bearing applications. The key to success is to apply microstructural design strategies to develop ceramic scaffolds with mechanical properties approaching those of bone. Here we report on the development of a unique microstructurally designed ceramic scaffold, strontium–hardystonite–gahnite (Sr–HT–gahnite), with 85% porosity, 500 μm pore size, a competitive compressive strength of 4.1 ± 0.3 MPa and a compressive modulus of 170 ± 20 MPa. The in vitro biocompatibility of the scaffolds was studied using primary human bone-derived cells. The ability of Sr–HT–gahnite scaffolds to repair critical-sized bone defects was also investigated in a rabbit radius under normal load, with β-tricalcium phosphate/hydroxyapatite scaffolds used in the control group. Studies with primary human osteoblast cultures confirmed the bioactivity of these scaffolds, and regeneration of rabbit radial critical defects demonstrated that this material induces new bone defect bridging, with clear evidence of regeneration of original radial architecture and bone marrow environment.  相似文献   

18.
Magnesium has shown potential application as a bio-absorbable biomaterial, such as for bone screws and plates. In order to improve the surface bioactivity, a calcium phosphate was coated on a magnesium alloy by a phosphating process (Ca–P coating). The surface characterization showed that a porous and netlike CaHPO4·2H2O layer with small amounts of Mg2+ and Zn2+ was formed on the surface of the Mg alloy. Cells L929 showed significantly good adherence and significantly high growth rate and proliferation characteristics on the Ca–P coated magnesium alloy (p < 0.05) in in-vitro cell experiments, demonstrating that the surface cytocompatibility of magnesium was significantly improved by the Ca–P coating. In vivo implantations of the Ca–P coated and the naked alloy rods were carried out to investigate the bone response at the early stage. Both routine pathological examination and immunohistochemical analysis demonstrated that the Ca–P coating provided magnesium with a significantly good surface bioactivity (p < 0.05) and promoted early bone growth at the implant/bone interface. It was suggested that the Ca–P coating might be an effective method to improve the surface bioactivity of magnesium alloy.  相似文献   

19.
Chemical guiding cues are being exploited to stimulate neuron adhesion and neurite outgrowth. In this study, an amino-functioned PLLA, lysine-capped PLLA [K-(CH2)n-PLLA (n = 2, 5, 8)], was synthesized with different length of linking spaces between lysine molecule and PLLA backbone. Drop-cast films were fabricated from K-(CH2)n-PLLA/PLLA blends (10/90, w/w) and amino groups were detected on the surfaces of the resultant films. More amine groups were detected on the surface and the hydrophilicity of the films was obviously improved by annealing the films in water. The representative atomic force microscopy (AFM) images indicated that incorporation of lysine-capped PLLA into PLLA matrix increased the roughness of the films and resulted in a phase separation with distinct two nano-domains which may correspond to the hydrophilic and hydrophobic domains. Furthermore, the laminin-derived peptides, CYIGSR (Cys-Tyr-Ile-Gly-Ser-Arg) and CSIKVAV (Cys-Ser-Ile-Lys-Val-Ala-Val), were jointly tethered to the amine groups of lysine-capped PLLA by a linking reagent sulfo-succinimidyl 4-(N-maleimidomethyl) cyclohexane-1-carboxylate (Sulfo-SMCC). The neonatal mouse cerebellum C17.2 stem cells were seeded on the peptides-grafted K-(CH2)n-PLLA/PLLA (n = 2, 5, 8) films and pure PLLA films were used as controls. Improved viability and longer neurites were obtained on the peptide-grafted films than PLLA film over the cultivation period, especially for K-(CH2)5-PLLA/PLLA, which had the highest peptide density of 0.28 ± 0.03 μg/cm2. This study highlights the potential of using the lysine-cappeded PLLA with laminin-derived peptides for promoting nerve regeneration.  相似文献   

20.
《Acta biomaterialia》2014,10(8):3505-3512
A water-soluble anthracycline antibiotic drug (daunorubicin, DNR) was loaded into oxidized porous silicon (pSiO2) microparticles and then encapsulated with a layer of polymer (poly lactide-co-glycolide, PLGA) to investigate their synergistic effects in control of DNR release. Similarly fabricated PLGA–DNR microspheres without pSiO2, and pSiO2 microparticles without PLGA were used as control particles. The composite microparticles synthesized by a solid-in-oil-in-water emulsion method have mean diameters of 52.33 ± 16.37 μm for PLGA–pSiO2_21/40–DNR and the mean diameter of 49.31 ± 8.87 μm for PLGA–pSiO2_6/20–DNR. The mean size, 26.00 ± 8 μm, of PLGA–DNR was significantly smaller, compared with the other two (P < 0.0001). Optical microscopy revealed that PLGA–pSiO2–DNR microspheres contained multiple pSiO2 particles. In vitro release experiments determined that control PLGA–DNR microspheres completely released DNR within 38 days and control pSiO2–DNR microparticles (with no PLGA coating) released DNR within 14 days, while the PLGA–pSiO2–DNR microspheres released DNR for 74 days. Temporal release profiles of DNR from PLGA–pSiO2 composite particles indicated that both PLGA and pSiO2 contribute to the sustained release of the payload. The PLGA–pSiO2 composite displayed a more constant rate of DNR release than the pSiO2 control formulation, and displayed a significantly slower release of DNR than either the PLGA or pSiO2 formulations. We conclude that this system may be useful in managing unwanted ocular proliferation when formulated with antiproliferation compounds such as DNR.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏