首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A fully automated microparticle enzyme immunoassay, IMx AUSAB, was developed for the detection and quantitation of antibody against hepatitis B surface antigen (anti-HBs). The IMx AUSAB assay can complete 24 tests in less than 45 minutes. Anti-HBs concentrations in specimens are calculated automatically by comparison of the specimen rate to values determined from a stored standard curve. IMx AUSAB sensitivity is 2-3 mIU/ml, equivalent in sensitivity to AUSAB RIA or EIA. Specimens from blood donors, diagnostic and hospital patients, hepatitis B vaccinees, and individuals with a variety of infectious and autoimmune diseases tested in parallel by IMx AUSAB and AUSAB RIA or IMx AUSAB and EIA gave overall qualitative agreement of 97.8% (1265/1293) and 99.1% (1281/1293), respectively. The prevalence of anti-HBs ranged from 5.9% in volunteer blood donors to 47.0% of specimens from a sexually transmitted disease clinic. Most discordant specimens (18/34) were low level reactive (less than 10 mIU/ml) by AUSAB RIA, but negative by IMx AUSAB and AUSAB EIA. These specimens were also negative for antibodies to hepatitis B core antigen (anti-HBc). Six discordants were low level reactive by IMx but negative by RIA and EIA. Three of these six specimens were also reactive for anti-HBc suggesting that the IMx AUSAB reactivity resulted from the presence of low level anti-HBs. Quantitative agreement between IMx AUSAB and RIA or IMx and EIA for 106 specimens ranging in anti-HBs concentration from 1 to 30,000 mIU/ml gave linear correlation coefficients of 0.91 and 0.96, respectively. The IMx test was useful for monitoring hepatitis B vaccine response and seroconversion levels after hepatitis B infection.  相似文献   

2.
A fully automated microparticle enzyme immunoassay (EIA), IMx Core, was developed for the detection of antibody against hepatitis B core antigen (anti-HBc). IMx Core sensitivity was less than 0.5 Paul Ehrlich Institut units per ml and was greater than that of the commercial radioimmunoassay (RIA) or EIA, Corab and Corzyme, respectively. Specimens from blood donors and diagnostic and hospital patients, which included individuals with a variety of infectious and immune diseases, were tested in parallel by the IMx Core and EIA. Overall agreement of 99.1% (4,797 of 4,841) was obtained. Prevalence of anti-HBc tested by IMx Core ranged from 1.2% in volunteer blood donors to 9.1% in hospital laboratories. Discordant specimens reactive by IMx Core but negative by Corzyme or Corab resulted from the increased sensitivity of the IMx Core assay, since other hepatitis B markers were usually present. However, most discordant specimens were positive by the EIA or RIA but negative by IMx Core. No other hepatitis B markers could be detected in these discordants, and after addition of reducing agent, these specimens also became negative by EIA or RIA. In clinical trials, 30% (14 of 47) of volunteer blood donors and 8% (9 of 119) of hospital patients testing repeatedly reactive by the EIA had reduction-sensitive (unspecific) anti-HBc reactivity. The reducing agent, dithiothreitol, was added to each specimen automatically in the IMx assay to eliminate these unspecific reactions without significantly affecting anti-HBc reactivity resulting from hepatitis B virus infection as judged by the correlation with other hepatitis B markers.  相似文献   

3.
A fully automated chemiluminescent microparticle immunoassay (Architect HBsAg QT) was used for the detection and quantitation of hepatitis B surface antigen (HBsAg). The assay is capable of processing up to 800 HBsAg tests per hour. The concentration of HBsAg is determined by utilizing a previously generated Architect HBsAg calibration curve. Architect HBsAg QT sensitivity was found to be around 0.2ng/ml which is equivalent or superior to other known and commercially available enzyme immunoassays and/or chemiluminescent immunoassays. We performed a quantitative study of HBsAg, HBeAg, HBV-DNA and HBV-DNA polymerase in over 733 sera obtained from 43 chronic hepatitis B carriers. Serum HBsAg levels detected by Architect HBsAg QT were found to be higher in HBeAg-positive than in anti-HBe-positive HBV chronic carriers and correlated with the level of serum HBV-DNA and HBV-DNA polymerase.  相似文献   

4.
BACKGROUND: Following an accidental observation of reduced sensitivity for detection of antibodies to hepatitis C virus (HCV) with a novel commercially available automated chemiluminescent microparticle immunoassay (CMIA, ARCHITECT Anti-HCV) compared to a well-established microparticle enzyme immunoassay (MEIA, AxSYM HCV Version 3.0), we wanted to explore whether this could be explained by a variation in marginal sensitivity, to be expected between highly sensitive assays of different formats, or represented a reduced sensitivity of the CMIA to certain antibody profiles. OBJECTIVES: To evaluate the ability of the CMIA to detect low concentrations of anti-HCV antibodies as defined by various patterns in the recombinant immunoblot assay (RIBA) and already detected in the MEIA system. STUDY DESIGN: All patient sera tested for anti-HCV reactivity during a period of 3 years (27,978) were evaluated. A total of 90 sera had a sample/cut-off ratio (S/CO) between 1.0 and 1.5 in the MEIA test and were available for further testing. Of these, 19 had a probable/possible presence of anti-HCV antibodies based on presence of at least two bands of > or = 1+ strength in the RIBA, or because the patient was known to be anti-HCV positive. These 19 sera were tested with the CMIA. In addition, 16 sera with strong reactivity to various antigen combinations in the RIBA were serially diluted until testing negative in both microparticle test systems. RESULTS: Seven of the 19 sera (37%) were negative (S/CO < 1.0) in the CMIA. At least 3 (16%) of these 19 sera were very likely to be true anti-HCV positive sera (from infants with known anti-HCV positive mothers). HCV-RNA was not detected in any of the sera tested. Testing of sera after serial dilution indicates that the CMIA has a lower sensitivity to c22- and c33c-antibodies than the MEIA, possibly also to c100-3-antibodies. CONCLUSION: Our findings indicate that ARCHITECT Anti-HCV is less sensitive than AxSYM HCV Version 3.0 in detecting antibodies to c22 and c33c in patients who have cleared their HCV-infection and have naturally declining levels of antibodies.  相似文献   

5.
The traditional approach to the diagnosis of viral hepatitis has been to collect a serum sample and to test it for the presence of hepatitis B surface antigen (HBsAg), IgM to the core of HBV (anti-HBc IgM) and IgM to HAV (anti-HAV IgM) by solid phase radio- or enzyme immunoassays. Microparticle enzyme immunoassay technology (IMx-Abbott Laboratories) has been introduced as an automated carousel system for the detection of these markers. A side-by-side, blinded comparison of IMx to current IA was performed for HBsAg on 659 specimens submitted from March to July 1990, of which 72 (10.8%) were positive by AUSRIA (Abbott RIA for HBsAg) and 2 of these were discordant in IMx. Both were near the cutoff and by confirmatory testing one was positive and the other negative. Forty three percent (25/58) of frozen stored sera tested for anti-HBc IgM, by IMx, were positive by EIA (Corzyme M). One specimen near the cutoff was negative by EIA but weakly positive by IMx. Anti-HAV IgM was found in 21.8% (46/211) of sera with 100% correlation by IMx. Thus IMx had the following percent sensitivies and specificities: HBsAg; 98.6, 99.9; anti-HBc IgM; 100, 99.9; anti-HAV IgM; 100, 100. The test set-up times for the 3 markers in the IMx were similar to the RIA and EIA. The turnover time was 45 min for a full IMx carousel compared to: AUSRIA-short incubation (4 h), or long incubation (14 h); Corzyme M-short (4.75 h) or long (20 h); anti-HAV IgM (23 h).(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

6.
We compared an automated microparticle double-antigen sandwich enzyme immunoassay (EIA) for the IMx test system recently developed by Abbott with two established assays (the automated indirect Vidas IgG EIA and the double-antigen sandwich EIA from Murex/Wellcome) devised for the detection of human immunodeficiency virus type 1 (HIV-1) and HIV-2 antibodies. A total of 1,078 consecutive serum samples were tested prospectively with the three assays. In addition, we used retrospectively selected panels of serum samples with discrepant results in two different screening tests and with indeterminate or positive Western immunoblot (WB) results, as well as five commercially available HIV-1 seroconversion panels. The new assay showed excellent discriminatory characteristics for the separation of samples from HIV-1-positive and HIV-1-negative persons according to Centers for Disease Control and Prevention WB criteria. The sensitivities were 98.1, 92.9, and 96.1% for the new test and the two other assays, respectively, and the specificities were 99.7, 97.9, and 98.1%, respectively. With the seroconversion panels this new test was positive several days earlier than the two other assays; i.e., seroconversion was evident at the peak of p24 antigenemia and often several weeks before WB became positive by the most stringent criteria.  相似文献   

7.
A new rapid serologic enzyme immunoassay for antibodies to hepatitis C virus (HCV) is described. The assay combines synthetic peptide and recombinant antigens representing putative structural and non structural HCV gene products with paramagnetic microparticle assay (MP assay) technology. Assay readout is based upon an enzymatically generated fluorescent product which is quantified with a novel semi-automated washer/reader instrument system. Assay sensitivity and specificity was determined to be greater than the first generation HCV C-100 EIA using a non-A, non-B hepatitis disease panel, an HCV performance panel, an HCV seroconversion panel, dilutions of HCV reactive sera, and random volunteer blood donor specimens.  相似文献   

8.
Enzyme immunoassays were developed for the detection of Breda virus antibody and antigen. Cattle sera collected in the United Kingdom were found to have a high prevalence of antibody (55%) to Breda virus when examined in a competitive enzyme-linked immunosorbent assay. A low prevalence of antibody was found in pigs (2.2%), and no antibody was found in sheep or goat sera. No antibody to either Breda virus or Berne virus was detected in human sera collected from veterinarians and farm workers. Only 1 of 430 human fecal specimens (0.2%) contained Breda virus antigen detectable by enzyme-linked immunosorbent assay.  相似文献   

9.
An automated microparticle enzyme immunoassay (IMx Rubella IgG Antibody Assay; Abbott Laboratories, North Chicago, Ill.) was compared with a conventional enzyme-linked immunosorbent assay (ELISA) for detection of rubella-specific immunoglobulin G (IgG) in 400 consecutive antenatal patients. There was complete agreement between the two tests in this population, which had a positivity rate of 99% for rubella-specific IgG antibodies. The performance of the IMx was also evaluated at the cutoff zone by assaying 64 selected antenatal serum samples with low or negative rubella antibody titers as determined by ELISA. Overall, the IMx was found to be a specific, sensitive assay for the detection of rubella-specific IgG and is virtually fully automated for easy performance.  相似文献   

10.
The measurement of antibodies to hepatitis E virus (anti-HEV) has been essential for understanding the epidemiology of hepatitis E. Studies to determine the prevalence of HEV infections require a reliable serologic assay that is sensitive and specific. It is also important to distinguish the acute from the convalescent phase of an infection; this usually requires the detection of the immunoglobulin M (IgM) class of antibody. Few enzyme immunoassays (EIAs) that measure IgM anti-HEV have been described, and most have utilized the sandwich method. The present study describes an EIA that detects IgM anti-HEV by antibody class capture methodology. The assay was validated by using serum and/or plasma panels from experimentally infected nonhuman primates. It was used to demonstrate an anamnestic response and the reappearance of IgM anti-HEV in a chimpanzee experimentally challenged with HEV at two different times 45 months apart. The class capture method was more sensitive than the sandwich EIA when used to test clinical samples from two hepatitis E epidemics in Pakistan; it also had the advantage of distinguishing IgM anti-HEV in the presence of high titers of IgG anti-HEV.  相似文献   

11.
Detection of Norwalk virus in stools by enzyme immunoassay   总被引:10,自引:0,他引:10  
The development of a solid-phase microtiter enzyme immunoassay (EIA) for detection of Norwalk virus antigen in stool samples is described. The EIA was compared with a previously developed radioimmunoassay (RIA) for detection of Norwalk virus antigen in stools obtained from 30 volunteers who received Norwalk virus. The EIA detected viral antigen in stools from 17 of the volunteers and the RIA detected viral antigen in 15. Seroconversion was a more sensitive indicator of infection in some patients. However, two samples from volunteers who were clinically ill but did not show seroconversion to Norwalk virus were positive for Norwalk virus antigen by both immunoassays. This indicates that antigen detection may be important for use in epidemiological studies. Neither of the immunoassays gave positive reactions for stools known to contain enteric adenovirus, rotavirus, or Hawaii virus, or in stools from patients with acute diarrhea of unknown cause. The stability of the EIA reagents and ease of use should provide a means for more extensive testing for Norwalk virus in outbreaks of gastroenteritis.  相似文献   

12.
We developed a quantitative enzyme immunoassay (EIA) for antibody to hepatitis E virus (HEV) by using truncated HEV capsid protein expressed in the baculovirus system to improve seroepidemiology, to contribute to hepatitis E diagnosis, and to enable vaccine evaluations. Five antigen lots were characterized; we used a reference antiserum to standardize antigen potency. We defined Walter Reed antibody units (WR U) with a reference antiserum by using the four-parameter logistic model, established other reference pools as assay standards, and determined the conversion factor: 1 WR U/ml = 0.125 World Health Organization unit (WHO U) per ml. The EIA performed consistently; median intra- and inter-test coefficients of variation were 9 and 12%, respectively. The accurate minimum detection limit with serum diluted 1:1,000 was 5.6 WR U/ml; the test could detect reliably a fourfold antibody change. In six people followed from health to onset of hepatitis E, the geometric mean antibody level rose from 7.1 WR U/ml to 1,924.6 WR U/ml. We used the presence of 56- and 180-kDa bands by Western blotting as a confirmatory test and to define true-negative and -positive serum specimens. A receiver-operating characteristics plot identified 30 WR U/ml as an optimum cut-point (sensitivity, 86%; specificity, 89%). The EIA detected antibody more sensitively than a commercially available test. The EIA was transferred to another laboratory, where four operators matched reference laboratory results for a panel of unknowns. Quantitation of antibody to HEV and confirmation of its specificity by Western blotting make HEV serology more meaningful.  相似文献   

13.
用原位酶联免疫吸附法检测甲型肝炎病毒   总被引:2,自引:0,他引:2  
目的 采用一种更加简单和敏感的检测方法对甲型肝炎病毒(HAV)进行检测。方法 用甲型肝炎病毒疫苗株H2M20K株和野毒株合34感染KMB17二倍体细胞,于96孔微量细胞板上培养,并在原位用HAV特异的单克隆抗体与单层细胞上的病毒结合,辣根过氧化物酶标记的抗鼠IgG作为指示,以细胞对照A值(OD)均数的18倍判为阳性。结果 病毒增殖动态显示,高峰期为20~25d,比ELISA终点滴定法提前4~6d;两种方法同时做13个样品的感染性滴度比较,结果差异无显著意义(t=1.13,P>0.05)。原位EIA较好地指示中和试验的结果;直接从12份粪便中分离病毒,经第一代培养检测有5份阳性。结论 EIA敏感性与ELISA法相似,由于原位EIA直接检测病毒细胞系统,有操作简单,重复性好等优点,可取代ELISA终点滴定法,同时也可望用于对其他病毒细胞系统的检测。  相似文献   

14.
A comparative evaluation of the following commercial immunoassays for the detection of hepatitis B virus surface antigen (HBsAg) was performed: the Abbott AxSYM, Abbott IMx, and DPC IMMULITE assays. The specificity was 100% for all assays. Twelve samples were identified and were confirmed to be positive for HBsAg by all three methods. One additional sample was identified as reactive and was confirmed to be positive by the Abbott AxSYM assay only. Prior to confirmation testing the DPC IMMULITE assay produced significantly fewer false-positive results than the Abbott AxSYM assay (P < 0.05).  相似文献   

15.
A solid-phase enzyme immunoassay (EIA) was developed to detect bluetongue (BT) virus antigens in infected cell cultures and in suspensions of infected Culicoides variipennis midges. The technique was equally sensitive for detecting the five U.S. BT virus serotypes (2, 10, 11, 13, and 17) in cell cultures. EIA reliably detected about 3.8 log10 median tissue culture infective doses per ml of BT virus in infected cell culture lysates. The EIA readily detected virus antigens in pools of midges infected with BT serotypes 2, 10, 11, 13, and 17 and contained 2.3 to 4.8 log10 median tissue culture infective doses per ml of BT virus. The technique was sensitive enough to detect a single infected midge in a pool with 99 noninfected midges. The EIA may be a sensitive and rapid alternative to virus isolation for surveillance of BT viruses in vector populations.  相似文献   

16.
Multiple studies have examined the use of oral fluids in modified serum-based assays aiming to replace serum in antibody detection for hepatitis A. However, the reliable detection of HAV immunity in oral fluid requires an extremely sensitive assay; most immunoassays designed for serum antibody determination lack sufficient sensitivity for this purpose. Consequently, an “in-house” competitive enzyme immunoassay (EIA) designed specifically for use with oral samples collected using a ChemBio® device was developed to detect total anti-HAV antibodies (IgG and IgM). This system was compared to an in-house competitive EIA and a commercial EIA considered to be the “gold standard” using corresponding serum samples (n = 225) to determine the accuracy of the assay and to evaluate the importance of the cutoff ratio for the detection of anti-HAV antibodies in oral fluids. When the median serum cutoff and the optimal oral fluid cutoff (ROC analysis) obtained from the in-house competitive EIA were compared, the oral fluid cutoff was found to be 28.8% higher than the serum cutoff. When different oral fluid cutoff values were compared, a reduction of about 17% was shown to be essential to increase test accuracy. At an oral fluid cutoff value of 0.351, sensitivity and specificity were higher, reaching 91.7% and 86.2% (p < 0.001, AUROC = 0.915), respectively. The convenience, accuracy and non-invasive nature of the developed method make it a useful alternative to serum-based assays for discriminating between HAV-immune and non-immune individuals.  相似文献   

17.
A sensitive and reproducible enzyme-linked immunoassay (ELISA) for IgA class antibodies against the Delta antigen (HDAg) is described. Specificity of the assay was demonstrated by the absence of binding to an unrelated antigen or to uncoated plates and the finding that binding to HDAg was independent of total IgA concentrations in sera. Positive results were obtained with sera from 11 of 14 patients with chronic Delta virus infection (seropositive for HBsAg and IgM anti-HDAg, negative for IgM anti-HBc) at serum dilutions of up to 1:10(6). Sera from four normal healthy individuals and from 25 patients with chronic hepatitis B or other liver disorders who had no evidence of exposure to HDV were all negative in the assay.  相似文献   

18.
Hepatitis C virus antibodies were detected by a second-generation enzyme immunoassay and investigated with a second-generation recombinant immunoblot assay. Most sera with optical density values of > or = 2.0, particularly those with optical densities of > or = 2.0 after a further 10-fold dilution, were positive in the second-generation recombinant immunoblot assay. Repeat testing of hemodialysis patients revealed excellent reproducibility and increased sensitivity of the second-generation enzyme immunoassay.  相似文献   

19.
Because some batch-to-batch variation in the preparation of rough lipopolysaccharide (RLPS) from Brucella ovis has been experienced, several protocols were tested to establish the most reliable method for detection of antibody in indirect enzyme immunoassay. An early version of the assay gave a performance index (PI=sum of optimum percent sensitivity and percent specificity, determined by receiver operator characteristic analysis) of 198.6. This assay used RLPS from B. ovis as the antigen and a monoclonal antibody specific for bovine IgG(1) heavy chain-enzyme conjugate for detection. This was not repeatable using other batches of antigen. Newer versions of the assay generally had decreased sensitivity values, giving PIs of 193. Use of a recombinant protein A/G-enzyme conjugate did not improve the PI (PI=190), giving reduced specificity and higher sensitivity. The final version used B. abortus RB51 RLPS as the antigen and protein A/G-enzyme conjugate for detection, giving a PI of 197. Because of the batch uniformity of the B. abortus RB51 RLPS and the versatility of the protein A/G-enzyme conjugate, the latter version appears to be the most useful for diagnostic serology.  相似文献   

20.
As infection with Pasteurella multocida is common in rabbits, an enzyme immunoassay (EIA) was developed for its detection. A murine immunoglobulin G monoclonal antibody was used to capture a 37-kDa polypeptide of P. multocida serotype A:12 in an EIA to detect antibodies to P. multocida. The 37-kDa antigen was selected since it was previously shown to be a major immunogen during P. multocida infection in rabbits. The sensitivity of the P37 EIA, determined with sera from 56 rabbits infected with P. multocida, was 98%. Specificity, evaluated with sera from 62 rabbits from colonies free of P. multocida, was 92%. Titration curves of sera from rabbits immunized with P. multocida serotype A:3 or A:12 coincided, indicating that the P37 EIA was equally efficient in detecting antibodies to the two major serotypes of the organism. Comparison of the P37 EIA with the current serodiagnostic test, a bacterial lysate EIA, revealed relatively good correlation (r = 0.68). However, specificity was greatly improved, as 34% of uninfected rabbits were falsely positive by the lysate EIA whereas only 3% of uninfected rabbits were falsely positive by the P37 EIA. The coefficient of variation for same-day tests was 10%, and that for interday tests was 15%, indicating good reproducibility. The greater sensitivity and specificity of the P37 EIA should significantly enhance diagnostic capability to identify rabbits infected with P. multocida.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号