首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Based on epidemiological and research evidence, HPV has a causal role in cervical carcinogenesis. Several HPV detection methods exist to date; the most commonly used method for detection of genital HPVs consists of nested PCR using the MY09/11 and GP5(+)/6(+) primer sets (MY/GP(+)). Recently, the PGMY09/11 primer set, a modified version of the MY09/11 primer set, was introduced for single PCR and was found to detect a wider range of HPV types. The next logical step was taken and the efficacy of nested PCR using the PGMY09/11 and GP5(+)/6(+) primer sets (PGMY/GP(+)) to detect HPV in cervical samples was evaluated. In this comparative study, nested PCR using the novel PGMY/GP(+) primer set combination was found to be more type sensitive than the nested PCR with the MY/GP(+) primer sets, detecting a wider range of HPV types, low copy HPVs, and better characterizing samples infected with multiple strains of HPV. Standardization and use of the PGMY/GP(+) PCR system could aid physicians in providing more efficient HPV screening and better treatment for patients.  相似文献   

2.
Using multiple PCR primer sets, we tried to optimize the detection of human papillomavirus (HPV) in DNA samples isolated from 361 frozen biopsy specimens from patients with invasive cervical carcinomas. The HPVs detected were placed into three distinct groups, including group I/Inex at Telelab (Skien, Norway) and group Ineg and group II at the Norwegian Radium Hospital (Oslo, Norway). The consensus primer sets were Oli-1b-oli-2i, My09-My11, Gp5-Gp6, and Gp(5+)-Gp6+ from the HPV L1 gene and CpI-CpIIG from the E1 gene. Using these consensus primers together with the type-specific primers from E6-E7, we found that 355 patients (98%) were HPV positive. Type-specific primers for HPV types 11, 16, 18, 31, 33, and 35 detected more HPV-infected patients than the most sensitive consensus primer set, while the three consensus primer sets My, Gp/Gp+, and Cp together detected more HPV-positive patients than the type-specific primers. Testing of sensitivity of the PCR with SiHa cells serially diluted in lymphocytes (HPV-negative cells) indicated a detection limit of 6,300 HPV type 16 DNA copies with consensus primers (My, Gp+, and Cp) and 126 original HPV type 16 DNA copies with type-specific primers. Comparison of the amplification results for consensus L1 primers and type-specific E6-E7 primers indicated the presence of L1 deletions in 23 of 56 samples. The conclusion is that in PCR detection systems, multiple consensus primers and type-specific primers should be used in order to detect all patients harboring HPV.  相似文献   

3.
A nested multiplex PCR (NMPCR) assay that combines degenerate E6/E7 consensus primers and type-specific primers was evaluated for the detection and typing of human papillomavirus (HPV) genotypes 6/11, 16, 18, 31, 33, 35, 39, 42, 43, 44, 45, 51, 52, 56, 58, 59, 66, and 68 using HPV DNA-containing plasmids and cervical scrapes (n = 1,525). The performance of the NMPCR assay relative to that of conventional PCR with MY09-MY11 and GP5+-GP6+ primers, and nested PCR with these two primer sets (MY/GP) was evaluated in 495 cervical scrapes with corresponding histologic and cytologic findings. HPV prevalence rates determined with the NMPCR assay were 34.7% (102 of 294) in the absence of cervical intraepithelial neoplasia (CIN 0), 94.2% (113 of 120) in the presence of mild or moderate dysplasia (CIN I/II), and 97.8% (44 of 45) in the presence of severe dysplasia (CIN III). The combination of all four HPV detection methods applied in the study was taken as "gold standard": in all three morphological subgroups the NMPCR assay had significantly (P < 0.0001) higher sensitivities than the MY09-MY11 and GP5+-GP6+ assays and sensitivities comparable or equal to those of the MY/GP assay. All 18 HPV genotypes investigated were detected among the clinical samples. The ratio of high- to low-risk HPV genotypes increased from 4:1 (80 of 103) in CIN 0 to 19:1 (149 of 157) in CIN I to III. Multiple infections were detected in 47.9% (124 of 259) of the patients. In conclusion, the novel NMPCR method is a sensitive and useful tool for HPV DNA detection, especially when exact HPV genotyping and the identification of multiple HPV infections are required.  相似文献   

4.
BACKGROUND AND OBJECTIVES: Human papillomaviruses (HPV) are the causal agent for the development of carcinomas in the cervix uteri and further pathological changes of the skin including mucosa, particularly warts, condylomas and dysplasias. Therefore, we investigated the efficacy of different consensus primers pairs for HPV detection by PCR using brushed samples from the oral cavity in comparison with samples from the cervix uteri. STUDY DESIGN: In the present study, we used two well-established sets of PCR primers in different combinations for the detection of HPV DNA in 106 non-invasive brush biopsy samples of the oral mucosa and 56 samples from the cervix uteri. Direct sequencing of PCR products in all cases determined HPV genotype and specificity. RESULTS: Overall, HPV was detected in 69 of 106 oral mucosa samples. HPV specific amplicons were obtained in 35.8% (N = 38) when using GP5+/6+ primers. The positivity rate was increased to 65.1% in a GP5+/6+ auto-nested PCR approach. In contrast, MY9/11 PCR and nested PCR with MY9/11 outer followed by GP5+/6+ inner primers yielded 2.2% and 16.1%, respectively. In gynaecological samples, PCR results were similar independent of the primer combination used. Thus, DNA quality and DNA content could be additional factors influencing the rate of positivity. CONCLUSION: For oral mucosa samples, auto-nested GP5+/6+ PCR is in our hands the most suitable approach for epidemiological studies because of its high sensitivity, high reliability and reproducibility as well as its relatively simple laboratory procedure.  相似文献   

5.
The novel PGMY L1 consensus primer pair is more sensitive than the MY09 and MY11 primer mix for detection and typing with PCR of human papillomavirus (HPV) DNA in genital specimens. We assessed the diagnostic yield of PGMY primers for the detection and typing of HPV by comparing the results obtained with PGMY09/PGMY11 and MY09/MY11/HMB01 on 299 genital samples. Amplicons generated with PGMY primers were typed with the line blot assay (PGMY-line blot), while HPV amplicons obtained with the degenerate primer pool MY09/MY11/HMB01 were detected with type-specific radiolabeled probes in a dot blot assay (standard consensus PCR test). Cervicovaginal lavage samples (N = 272) and cervical scrape samples (N = 27) were tested in parallel with both PCR tests. The PGMY-line blot test detected the presence of HPV DNA more frequently than the standard consensus PCR assay. The concordance for HPV typing between the two assays was 84.3% (214 of 255 samples), for a good kappa value of 0.69. Of the 177 samples containing HPV DNA by at least one method, 40 samples contained at least one HPV type detected only with PGMY-line blot, whereas positivity exclusively with the standard consensus PCR test was found for only 7 samples (P < 0.001). HPV types 45 and 52 were especially more frequently detected with PGMY than MY primers. However, most HPV types were better amplified with PGMY primers, including HPV-16. Samples with discordant results between the two PCR assays more frequently contained multiple HPV types. Studies using PGMY instead of MY primers have the potential to report higher detection rates of HPV infection not only for newer HPV types but also for well-known genital types.  相似文献   

6.
Improved amplification of genital human papillomaviruses   总被引:18,自引:0,他引:18       下载免费PDF全文
Genital human papillomaviruses (HPVs) are commonly detected from clinical samples by consensus PCR methods. Two commonly used primer systems, the MY09-MY11 (MY09/11) primers and the GP5+-GP6+ (GP5+/6+) primers, amplify a broad spectrum of HPV genotypes, but with various levels of sensitivity among the HPV types. Analysis of the primer-target sequence homology for the MY09/11 primers showed an association between inefficient amplification of HPV types and the number and position of mismatches, despite accommodation of sequence variation by inclusion of degenerate base sites. The MY09/11 primers were redesigned to increase the sensitivity of amplification across the type spectrum by using the same primer binding regions in the L1 open reading frame. Sequence heterogeneity was accommodated by designing multiple primer sequences that were combined into an upstream pool of 5 oligonucleotides (PGMY11) and a downstream pool of 13 oligonucleotides (PGMY09), thereby avoiding use of degenerate bases that yield irreproducible primer syntheses. The performance of the PGMY09-PGMY11 (PGMY09/11) primer system relative to that of the standard MY09/11 system was evaluated with a set of 262 cervicovaginal lavage specimens. There was a 91.5% overall agreement between the two systems (kappa = 0.83; P < 0.001). The PGMY09/11 system appeared to be significantly more sensitive than the MY09/11 system, detecting an additional 20 HPV-positive specimens, for a prevalence of 62.8% versus a prevalence of 55.1% with the MY09/11 system (McNemar's chi(2) = 17.2; P < 0.001). The proportion of multiple infections detected increased with the PGMY09/11 system (40. 0 versus 33.8% of positive infections). HPV types 26, 35, 42, 45, 52, 54, 55, 59, 66, 73, and MM7 were detected at least 25% more often with the PGMY09/11 system. The PGMY09/11 primer system affords an increase in type-specific amplification sensitivity over that of the standard MY09/11 primer system. This new primer system will be useful in assessing the natural history of HPV infections, particularly when the analysis requires HPV typing.  相似文献   

7.
BACKGROUND: Around half a million new cases of cervical cancer are diagnosed worldwide each year, accounting for almost 300,000 deaths. Development of cervical cancer can be multi-factorial, but high-risk human papillomaviruses (HPV) have been associated with the aetiology of cervical cancer. It is believed that HPV DNA integrates into the host DNA causing abnormal cell growth with cells becoming carcinogenic and spreading metastatically. In Mauritius, cervical cancer account for 65% of gynaecological cancers and 3.4% of the cervical cancers are diagnosed at the stage of carcinoma in situ. OBJECTIVES: To determine the prevalence of HPV in histological samples from patients with cervical cancer in Mauritius. STUDY DESIGN: DNA from archival cervical samples from a cohort of 65 patients suffering from cervical cancer and controls from Mauritius were tested for the presence of HPV using MY09/11 and GP5+/6+ primer sets. RESULTS: In a cohort of 65 patients from Mauritius, diagnosed with cervical cancer in the year 2000, 19% of cervical histology sections were found to be positive for the presence of high-grade HPV, exclusively HPV18 using MY09 and MY11 primers. Only 15% of the Mauritian population is over 50 years of age, whereas 66% (35) of the diagnosed cases of cervical cancer were seen in patients above 50 years with 50% (5) affected with HPV. These findings suggest that for an infection with HPV to develop into cancer may take years if not decades. Differences were noted using two different primer sets, MY09/11 and GP5+/6+. The latter produce a much smaller amplicon (150bp) compared to the former ( approximately 450bp). Seven additional positive cases were detected with the GP5+/6+ primer set, resulting in an apparent prevalence of 32% as compared to the 19% seen with the MY09/11 primer set. This may indicate that some degradation of the target DNA has occurred during processing and storage of histological samples. CONCLUSION: Using primer sets MY09/11 and GP5+/6+, only HPV type 18 was found in the Mauritian cohort with a prevalence of 32%.  相似文献   

8.
In order to examine a sensitive unbiased consensus PCR with routine sequencing for HPV typing, we analysed Danish male and female patients suspected of having an HPV infection. We used the well-characterised nested PCR setting with MY09/MY11 and GP5+/GP6+ primers, followed by routine cycle sequencing. Of 1283 clinical samples from female patients based on suspected HPV infection, we found 379 (29%) negatives and 894 (70%) positives. Samples containing >5000 HPV copies/ml were genotyped by sequencing. Of the 552 HPV genotyped samples from women >15 years of age, 398 were characterised as high-risk types and the remaining 154 as low-risk types. The most commonly found high-risk types were HPV-16, HPV-31, HPV-33, HPV-18, HPV-58, and HPV-52, and the most commonly found low-risk types were HPV-6, HPV-53 and HPV-11. In addition, we observed that other typing assays could not perform as sensitively or accurately as the nested PCR/cycle sequencing method used in this study. For instance, 87 out of 552 genotyped samples could not have been typed correctly in the Hybrid Capture II assay. Of these 87 samples, 46 (53%) were considered as high-risk types.  相似文献   

9.
Human papillomavirus (HPV) is the main risk factor associated with the development of cervical cancer (CC); however, there are other factors, such as immunosuppression caused by the human immunodeficiency virus (HIV), that favor progression of the illness. This study was thus aimed at evaluating the functionality of classical PCR-based molecular tests for the generic identification of HPV DNA (GP5+/GP6+, MY09/MY11, and pU1M/2R primers, individually or in combination) using cervical and urine samples from 194 HIV-positive women. Infected samples were tested with type-specific primers for six high-risk types (HPV-16, -18, -31, -33, -45, and -58) and two low-risk types (HPV-6 and -11). HPV infection prevalence rates were 70.1% for the cervical samples and 63.9% for the urine samples. HPV-16 was the most prevalent viral type in the cervical and urine samples, with higher rates of multiple infections than single infections detected in such samples. HPV DNA detection by PCR (mainly with the pU1M/2R primer set) in urine samples was positively associated with abnormal cytological findings (atypical squamous cells of undetermined significance/squamous intraepithelial lesions [ASCUS/SIL]). It was determined that the operative characteristics for detection of cytological abnormalities were similar for cervical and urine samples. This suggested using PCR for the detection of HPV DNA in urine samples as a potential screening strategy for CC prevention in future prevention and control programs along with currently implemented strategies for reducing the impact of the disease, i.e., urine samples are economical, are easy to collect, have wide acceptability among women, and have operative characteristics similar to those of cervical samples.  相似文献   

10.
Human papillomavirus (HPV) is an etiologic agent of cervical cancer and is the most common sexually transmitted disease in women. PCR amplification of HPV genomes is the most sensitive method for the detection of cervicovaginal HPV. We have compared the two most commonly used PCR primer sets, MY09/MY11 (MY-PCR) and GP5+/GP6+ (GP+-PCR), for the detection of HPV DNA in cervicovaginal lavage samples from 208 women. Oligonucleotide probes for 39 different HPV types were used. Both primer sets amplified a wide spectrum of HPV genotypes and detected similar overall prevalences of 45% (94 of 208) and 43% (89 of 208), respectively. The MY-PCR system detected 27 of 30 (90%) samples with multiple HPV types, whereas the GP+-PCR system detected 14 of 30 (47%) samples with multiple HPV types. Differences in the detection of HPV types 35, 53, and 61 were noted between the two primer systems. Serial dilution of plasmid templates indicated a 3-log decrease in the amplification of HPV type 35 by MY-PCR and HPV types 53 and 61 by GP+-PCR. These results indicate that although the MY-PCR and GP+-PCR identified nearly equivalent prevalences of HPV in a set of clinical samples, differences in the detection of specific types and infections with multiple types were found. Differences in the sensitivities and characteristics of the PCR systems for the detection of HPV within clinical samples should be considered when comparing data between studies and/or in designing new studies or clinical trials.  相似文献   

11.
A single-tube real-time nested polymerase chain reaction (PCR) was developed to detect human Papillomavirus (HPV) DNA in a closed tube system. The oligonucleotide primers MY09/MY11 and GP5+/GP6+ were included in contiguous reactions, thus eliminating the need to transfer first round PCR product into a second tube. The sensitivity and specificity of the optimized single-tube nested PCR were comparable with that achieved by two separate reactions on a conventional thermal block system using serial dilutions derived from plasmids containing DNA of 20 HPV types. A minimum of 10 copies of HPV types 11 and 16 DNA could be detected by both systems. In clinical samples, HPV types 1A, 2, 3, 5, 6-8, 10, 11, 14, 16, 17, 18, 20, 31, 33, 35, 39, 45, 49, 50, 52-54, 57, 62, 66, 70, CP8304 and LVX82/MM7 could be detected by both PCR methods. A total of 145 samples collected from patients were tested for the presence of HPV DNA with the two PCR systems; 124 (86.1%) of 144 samples gave concordant results in both assays. The HPV DNA positive PCR amplicons were typed and concordant results were obtained in 47 of 67 positive samples tested in both amplicons. In samples containing multiple HPV types at least one type was common to both amplicons.  相似文献   

12.
Human papillomaviruses (HPVs) are major causative agents in the pathogenesis of cervical cancer, and more than twenty types are associated with its development. With the introduction of liquid-based preparation systems, it is envisaged that large-scale HPV testing will be established in the near future. Preliminary studies demonstrate the accessibility of these samples for DNA testing using both the Digene Hybrid Capture assay (DHCA) and polymerase chain reaction (PCR) techniques. This study aims to assess the validity and sensitivity of the DHCA system to detect high-risk HPV DNA, using two sets of HPV consensus primers (Gp5+/Gp6+ and MY09/MY11) in tandem with routine assessment of cervical smear and biopsy samples. Results indicate that the combination of DHCA and PCR detects more high-grade lesions than does the DHCA alone. DHCA-negative cases were categorised by subsequent PCR amplification into low-grade HPV-negative (12/16) cervical lesions and high-grade HPV-positive (7/9) cervical lesions. Gp5+/Gp6+ primers were less sensitive in detecting HPV-positive samples than was the MY09/MY11 primer set. These results support the use of high-risk HPV testing by DHCA, with subsequent analysis of DHCA-negative samples by PCR using the MY09/MY11 primers.  相似文献   

13.
AIM: To develop a unified diagnostic approach for the detection of human papillomavirus (HPV) DNA in skin and mucosal biopsies from both immunocompetent and immunosuppressed individuals using a degenerate polymerase chain reaction (PCR) method. METHODS: The sensitivity and specificity of three published degenerate primer sets (HVP2/B5 and F14/B15; MY09/MY11; CP62/69 outer and CP65/68 nested primer pairs) were evaluated in PCR reactions with serial dilutions of 12 representative cloned HPV types. This combination of primers was then used to detect HPV DNA in 49 benign and malignant lesions of cutaneous and mucosal origin from immunosuppressed, immunocompetent, and epidermodysplasia verruciformis (EV) patients, and compared with detection rates using single primer sets alone. RESULTS: The observed sensitivity of MY09/MY11 and CP62/69 + CP65/68 was high for mucosal and EV HPV types, respectively. The sensitivity of all primer sets for cutaneous types was low, but nonetheless the use of this combination of primers allowed HPV DNA detection in all of the benign warts analysed. Several mixed infections were also identified. A high prevalence of HPV DNA was similarly detected in squamous cell carcinomas from immunocompromised patients; the HPV types found were exclusively EV related. CONCLUSIONS: The use of a combined degenerate primer PCR approach considerably improves HPV DNA detection over individual primer sets and allows detection of mixed infections. The findings may help explain the discrepancies in published reports relating to HPV DNA detection in benign and malignant skin lesions. Further modifications to this method are in progress which should significantly improve comprehensive HPV detection and typing for diagnostic purposes.  相似文献   

14.
Human papillomavirus associated with oesophageal cancer   总被引:13,自引:0,他引:13  
AIM: To study the prevalence and the different types of human papillomavirus (HPV) in patients with oesophageal cancer from a high risk area of South Africa (Transkei). METHODS: DNA samples from 50 paraffin wax embedded tissue sections were analysed by nested polymerase chain reaction (PCR) using the degenerate HPV L1 consensus primer pairs MY09/MY11 and GP5+/GP6+. Positive PCR samples were subjected to DNA sequence analysis. RESULTS: HPV DNA was detected in 23 of the 50 samples. Sequence analysis revealed that most patients (11) harboured DNA to HPV type 11, whereas other types included DNA HPV type 39 (seven patients), type 16 (two patients), and type 52 (one patient). HPV type 39 has not previously been shown to be associated with oesophageal cancer. In contrast to earlier studies that have found HPV type 16 to be more frequently associated with oesophageal cancer, HPV type 11 was the predominant subtype in this study. CONCLUSIONS: The high frequency of occurrence of HPV in oesophageal tumours (23 of 50 patients; 46%) implicates HPV as one of the possible aetiological factors in this disease. The finding that the low risk HPV subtypes predominate indicates that transformation may be effected via the E6 and E7 proteins.  相似文献   

15.
An optimal method for the processing of archival cervical Papanicolaou (pap)-stained smears for the amplification of human papillomavirus (HPV) DNA by polymerase chain reaction (PCR) was developed. This methodology was then applied to a series of 44 pap smears designated as HPV positive or negative (on the basis of both major and minor cytological criteria) or cervical intraepithelial neoplasia (CIN)-cancer. For the detection of HPV DNA, each sample was tested with the consensus GP5/6 primers, and when negative, with CPI-IIG primers. The HPV DNA was detected in 100% (8 of 8) of CIN-cancer smears using the GP5/6 primers. In smears with cytological evidence of HPV without CIN. the use of both sets of primers yielded positive results in 100% (19 of 19) of the samples. Direct sequence analysis of PCR products showed that 16 of the 27 HPV-positive samples contained more recently described HPV types. When tested with both primer combinations, all 17 cytologically negative smears were positive for beta-globin but negative for HPV DNA. The findings show the value of using archival pap smears for further investigations to address issues such as latency, but they indicate that cytological criteria and DNA technology will be critical factors in the reliability of the results.  相似文献   

16.
An in-house polymerase chain reaction direct sequencing (PCR-DS) approach for HPV detection and typing was developed, taking advantage of two widely used pairs of human papillomavirus (HPV)-specific PCR primers, MY09/MY11 and GP5/GP6, and 33P-labeled dideoxynucleotides. In this study, 105 pathological specimens were examined: 89% were diagnosed as cervical intraepithelial neoplasia (CIN) grade I-III, 76.2% were HPV-positive by PCR-DS. The PCR using GP5/GP6 (first tier) and MY09/MY11 primers (second tier for the GP5/GP6-negative samples) detected additional 15%-25% HPV-positive samples compared with each pair used separately. Direct sequencing was then used to type the HPV. A readout of a sequence as short as 34 nucleotides within a specific region in the L1 gene is sufficient to type known or novel sequences. Because of its high sensitivity and cost-effectiveness, the two-tier PCR-DS was adopted by the authors as the current method of choice for HPV diagnosis with ultimate sequence precision.  相似文献   

17.
The aims of this study were to determine the prevalence of HPV infection and evaluate the concordance and performance of two primer sets for detecting single and multiple viral infections. A total of 1810 Colombian women were enrolled in the study, and molecular, cytological and epidemiological analyses were performed. Both concordance and performance of two different PCR amplification primer sets (GP5+/6+ and MY09/11) were assessed. The results showed that 60.2% of females with positive HPV DNA were infected by more than one viral type. The OR for multiple infections was 18.2 when using the MY09/11 primer set and 6.52 with the GP5+/6+ primer set. The results also showed an association between GP5+/6+ positivity and the severity of the disease regarding the cytological findings. It was also found that using a single primer set led to underestimating the prevalence for HPV infection. The simultaneous use of these primer sets is an important tool for the detection of HPV DNA, being equally relevant for identifying multiple infections and low viral DNA copies. This study highlights the importance of suitable assessment of HPV epidemiological profiles; screening programs must also be strengthened to broaden the coverage of the most vulnerable populations.  相似文献   

18.
To elucidate the putative role of human papillomavirus (HPV) infection in the etiology of conjunctival tumors, 44 formalin-fixed, paraffin-embedded specimens of conjunctival tumors (24 patients with papillomas and 20 patients with dysplastic and/or malignant tumors) were screened for HPV infection using 4 different polymerase chain reactions (PCRs). Of the 24 samples of papilloma, 14 (58%) displayed positive results by applying nested PCR using primer sets of HPV consensus L1 region. HPV type 6 or 11 was detected in 9 cases of papilloma by type-specific primer sets, but none of them were positive for HPV type 16 or 18. However, by using the highly sensitive PCR technique, we failed to demonstrate the HPV DNA of HPV types 6, 11, 16, and 18 in any of the 20 malignant epithelial tumors of conjunctiva. We conclude that HPV-6 or HPV-11 is present in a substantial percentage of conjunctival papillomas, which is in accordance with findings of previously reported studies. In contrast, malignant conjunctival carcinomas are not associated with HPV infection; other pathogenic mechanisms, such as UV light, probably are more important in the cause of these malignant lesions.  相似文献   

19.
应用聚合酶链反应检测食管癌组织中人乳头瘤病毒   总被引:1,自引:2,他引:1  
目的 探讨人乳头瘤病毒(human papillomavirus,HPV)与我国河南地区食管癌发生的相关性.方法 应用HPV L1通用引物GP5+/6+、HPV16E6和HPV18E6型特异性引物多聚酶链反应(Polymerase chain reaction,PCR),检测林州市食管癌组织中HPV存在状况.结果 31例食管癌组织中,29例检测到HPV阳性,阳性率为93.5%;其中19例检测到HPV16 E6基因,阳性率为61.3%,8例为HPV18 E6基因阳性,阳性率为25.8%,5例HPV16E6和18E6基因均阳性,为混合感染.HPV16和18型阳性率为71.0%.结论 我国河南省林州市食管癌组织中有HPV存在,并且HPV感染可能是食管癌发生的重要病因.  相似文献   

20.
保定地区食管癌患者癌组织中人乳头瘤病毒感染的检测   总被引:1,自引:1,他引:0  
目的 探讨人乳头瘤病毒(human papillomavirus,HPV)与我国河北省保定地区食管癌发生的相关性.方法 应用HPV LI通用引物GP5+,6+、HPV16 E6和HPV18 E6型特异性引物多聚酶链反应(Polymerase chain reaction,PCR),检测保定地区食管癌组织中HPV存在状况.结果 42例食管癌组织中,37例检测到HPV阳性,阳性率为88.1%;其中19例检测到HPV16 E6基因,阳性率为45.2%,8例为HPV18 E6基因阳性,阳性率为19.0%,5例HPV16 E6和18 E6基因均阳性,为混合感染.结论 我国河北省保定地区食管癌组织中有HPV存在,并且HPV感染可能是食管癌发生的重要影响因子.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号