首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
ObjectiveThe purpose of this study was to determine the microtensile bond strength of various resin composite/adhesive systems to alumina particle abraded Ti–6Al–4V substrate after aging for 24 h, 10 days, and 30 days in distilled water at 37 °C.MethodsFour laboratory resin composite veneering systems (Gradia, GR; Solidex, SOL; Ceramage, CER; and Sinfony, SF) were bonded to 25 mm diameter machined disks of Ti–6Al–4V with their respective adhesive and methodology, according to the manufacturer's instructions. Microtensile bars of approximate dimensions 1 mm × 1 mm × 6 mm were prepared for each resin composite/adhesive system. After cutting, groups (n = 12) from each adhesive system were separated and either stored in water at 37 °C for 24 h (baseline) or aged for 10 or 30 days prior to loading to failure under tension at a cross head speed of 1.0 mm/min. Failure modes were determined by means of scanning electron microscopy (SEM). Statistical analysis was performed through one-way ANOVA and Tukey's test at 95% level of significance.ResultsSignificant variation in microtensile bond strength was observed for the different systems and aging times. SOL and GR showed the highest mean bond strength values followed by SF and CER at baseline. Aging specimens in water had an adverse effect on bond strength for SOL and CER but not for the SF and GR groups.SignificanceIn vitro bond strength of laboratory resin composites to Ti–6Al–4V suggests that strong bonds can be achieved and are stable for certain systems, making them useful as an alternative for esthetic fixed prosthetic restorations.  相似文献   

2.
《Dental materials》2014,30(12):e306-e316
ObjectivesDental zirconia restorations should present long-term clinical survival and be in service within the oral environment for many years. However, low temperature degradation could affect their mechanical properties and survival. The aim of this study was to investigate the effect of in vitro aging on the flexural strength of yttrium-stabilized (Y-TZP) zirconia ceramics for ceramic restorations.MethodsOne hundred twenty bar-shaped specimens were prepared from two ceramics (ZENO Zr (WI) and IPS e.max® ZirCAD (IV)), and loaded until fracture according to ISO 6872. The specimens from each ceramic (nx = 60) were divided in three groups (control, aged for 5 h, aged for 10 h). One-way ANOVA was used to assess statistically significant differences among flexural strength values (P < 0.05). The variability of the flexural strength values was analyzed using the two-parameter Weibull distribution function, which was applied for the estimation of Weibull modulus (m) and characteristic strength (σ0). The crystalline phase polymorphs of the materials (tetragonal, t, and monoclinic, m, zirconia) were investigated by X-ray diffraction (XRD) analysis, Raman spectroscopy and Fourier transform infrared (FTIR) spectroscopy.ResultsA slight increase of the flexural strength after 5 h, and a decrease after 10 h of aging, was recorded for both ceramics, however statistically significant was for the WI group (P < 0.05). Both ceramics presented a t  m phase transformation, with the m-phase increasing from 4 to 5% at 5 h to around 15% after 10 h.SignificanceThe significant reduction of the flexural strength after 10 h of in vitro aging, suggests high fracture probability for one of the zirconia ceramics tested.  相似文献   

3.
PurposeThe purpose of this study was to evaluate the effect of pretreatment using phosphoric acid, sodium hypochlorite and sulfinic acid sodium salt on the bonding of one-step self-etching adhesives to root canal dentin.MethodsThirty-six single-rooted sound human premolars were randomly assigned into three groups before applying the one-step self-etching adhesive. These comprised a control group with no pretreatment, an NC group that received phosphoric acid and subsequent sodium hypochlorite gel pretreatments, and an NC + AC group that received an additional treatment with sulfinic acid sodium salt following the same pretreatment applied to the NC group. Microtensile bond strength measurements, bonding interface observations by scanning electron microscopy (SEM), elemental analyses by X-ray photoelectron spectroscopy (XPS) and degree of polymerization (DOP) analyses by Raman spectroscopy were subsequently performed.ResultsThe bond strength was significantly higher in the NC + AC group than in the other two groups (Control: P = 000.1 and NC: P = 0.004). SEM observations showed that resin tags were present in the dentinal tubules in the NC and NC + AC groups. Compared to the control group, the adhesive resin layer had a lower DOP in the NC group, while the DOP for the NC + AC group was higher than that of the NC specimens.ConclusionsBonding to root canal dentin was improved by applying sulfinic acid sodium salt in addition to treatment with phosphoric acid followed by sodium hypochlorite. The DOP of the adhesive resin was reduced by sodium hypochlorite and subsequently restored by applying sulfinic acid sodium salt.  相似文献   

4.
ObjectivesTo evaluate the effect of surface conditioning on the microtensile bond strength of zirconium-oxide ceramic to dual-cured resin cements.MethodsEighteen cylinder-shaped zirconium-oxide ceramic blocks (Cercon® Zirconia, Dentsply) were treated as follows: (1) Sandblasting with 125 μm aluminum-oxide (Al2O3) particles; (2) tribochemical silica coating using 50 μm Al2O3 particles modified by silica; (3) no treatment. Each ceramic cylinder was duplicated in composite resin (Tetric Evo Ceram, Ivoclar-Vivadent) using a silicon mold. Composite cylinders were bonded to conditioned ceramics using: (1) Calibra (Densply Caulk); (2) Clearfil Esthetic Cement (Kuraray); (3) Rely × Unicem (3 M ESPE). After 24 h bonded specimens were cut into microtensile sticks that were loaded in tension until failure. Data were analyzed using two-way ANOVA and Student–Newman–Keuls test for multiple comparisons (p < 0.05). Failure mode was recorded and the interfacial morphology of debonded specimens was observed using a scanning electron microscope (SEM). Surface topography and ceramic average surface roughness were analyzed under an atomic force microscope (AFM).ResultsSignificant changes in zirconia surface roughness occurred after sandblasting (p < 0.001). Bond strength of Clearfil cement to zirconia was significantly higher than that of Rely × Unicem and Calibra, regardless of the surface treatment (p < 0.001). When using Calibra, premature failures occurred in non-treated and silica coated zirconia surfaces.SignificanceThe phosphate monomer-containing luting system (Clearfil Esthetic Cement) is recommended to bond zirconia ceramics and surface treatments are not necessary.  相似文献   

5.
ObjectivesTo evaluate the effect of the particle size of sandblasting and the composition of the resin cement on the microtensile bond strength (MTBS) to zirconia.MethodsForty zirconia blocks (Cercon, Dentsply) were polished and randomly treated as follows: Group 1 (NT): no treatment; Group 2 (APA-I): airborne particle abrasion (Cobra, Renfert) using 25-μm aluminium-oxide (Al2O3)-particles; Group 3 (APA-II): APA with 50-μm Al2O3-particles; and Group 4 (APA-III): APA using 110-μm Al2O3-particles. Ceramic blocks were duplicated in composite resin. Samples of each pretreatment group were randomly divided into two subgroups depending on the resin cement used for bonding the composite disks to the treated zirconia surfaces. Subgroup 1 (PAN), which was a 10-MDP-containing luting system, used Clearfil Ceramic Primer plus Panavia F 2.0 (Kuraray) and Subgroup 2 (BIF) used Bifix SE (VOCO) self-adhesive cement. After 24 h, bonded specimens were cut into 1 ± 0.1 mm2 sticks. MTBS values were obtained using a universal testing machine (cross-head speed = 0.5 mm/min). Failure modes were recorded and the interfacial morphology of the debonded microbars was SEM-assessed. Two-way ANOVA, Student–Newman–Keuls tests, and the step-wise linear regression analysis were performed with the MTBS being the dependent variable (p < 0.05).ResultsDespite the sandblasting granulometry, PAN bonded to air-abraded surfaces attained the highest MTBS and frequently showed mixed fractures. BIF recorded no significant differences in MTBS depending on the conditioning method, and registered the highest rates of premature and adhesive failures.ConclusionsThe 10-MDP-containing luting system seems to be the most suitable to bond zirconium-oxide ceramic, mainly after sandblasting.  相似文献   

6.
《Dental materials》2019,35(11):1557-1567
ObjectiveTo evaluate the effect of surface treatments on yttria-tetragonal zirconia polycrystal (Y-TZP) characteristics and on resin-mediated zirconia bond.MethodsY-TZP slabs were grit blasted with 45 μm alumina or with 30 μm silica-coated alumina particles. The chemical treatments were: no-chemical treatment (NC), silane-containing primer (SP), MDP (10-Methacryloyloxydecyl dihydrogen phosphate) and silane-containing primer (MPS), MDP-containing primer (MP) and MDP and silane-containing adhesive (MPA). Contact angle as a function of surface roughness (θm) and surface roughness parameter (Sdr) were measured using Fringe Projection Phase Shifting (FPPS). Surface free energy (γsTOT) was calculated with a goniometer. Chemical interaction between primers/adhesive and zirconia was analyzed using time-of-flight secondary ion mass spectrometry (ToF-SIMS). Resin cement microshear bond strength (μSBS) was analyzed at either 24-h or 8-months water storage (37 °C). θm values, Sdr values, γsTOT and μSBS values were analyzed using Analysis of variance (ANOVA) and post hoc Tukey test (α = 0.05).ResultsChemical treatment had an effect (p < 0.001) on all surface parameters analyzed: θm, γsTOT and Sdr. MP-treated group showed higher incidence of P–O–Zr bonds than the other groups, indicating more chemical linkages. Grit blasting (p < 0.001) and the interaction chemical treatment*storage (p < 0.001) did not affect μSBS; all silane-containing primers showed significant drop in μSBS after aging.SignificanceMDP and/or silane-based solutions affect the physicochemical properties of blasted-zirconia. An MDP-based primer is fundamental to achieve a stable resin-zirconia bonding, but the chemical reactivity of MDP is impaired when this molecule is present in a multicomponent system.  相似文献   

7.
ObjectivesInformation regarding the effects of orthodontic bracket debonding on zirconia restorations, and the preferred method for residual adhesive removal from the zirconia restoration surface is lacking. Thus, this study aimed to assess the effects of different methods of residual adhesive removal after orthodontic bracket debonding on flexural strength, surface roughness, and phase transformation of high-translucent (HT) zirconia.Materials and methodsThis in vitro study evaluated 72 bar-shaped HT zirconia specimens; 18 specimens were assigned to the control group. Metal brackets were bonded to the remaining specimens by resin cement. After bracket debonding, the residual adhesive on the surface of specimens was removed by three methods (n = 18): a 30-flute tungsten-carbide (TC) bur at low speed, an ultrafine diamond bur at high speed, and Er:YAG laser irradiation. The surface roughness (Ra and Rz) was measured. X-ray diffraction (XRD) analysis was carried out, and the flexural strength was measured as well. Data were statistically analyzed (α = 0.05).ResultsBefore polishing, all methods increased the Ra and Rz values (P < 0.05) except for the diamond bur yielding a Rz value comparable to that of the control group. The Ra values of the test groups were comparable after polishing, and still higher than that of the control group (P < 0.05). The flexural strength of all three test groups was comparable (P > 0.05), and significantly lower than that of the control group (P < 0.001). The monoclinic phase was not observed in any group.ConclusionsOrthodontic bracket debonding adversely affects the surface roughness and flexural strength of zirconia despite polishing.  相似文献   

8.
《Dental materials》2014,30(4):408-416
ObjectiveEvaluate the effect of implant connection designs on reliability and failure modes of screw-retained all-ceramic crowns.MethodsCentral incisor ceramic crowns in zirconia abutments were screwed and torqued down to external hexagon (EH), internal hexagon (IH) and Morse taper (MT) implant systems. Single-load-to-fracture (SLF) test (n = 4 per group) determined three step-stress fatigue profiles with specimens assigned in the ratio of 3:2:1. Fatigue test was performed under water at 10 Hz. Use level probability Weibull curves and reliability for missions of 50,000 cycles at 400 N and 200 N were calculated (90% confidence bounds-CB). Weibull probability distribution (90% CB) was plotted (Weibull modulus vs characteristic strength) for comparison between the groups. Fractographic analyses were conducted under polarized-light microscopy and SEM.ResultsUse level Weibull probability calculation indicated that failure was not associated with fatigue in groups EH (β = 0.63), IH (β = 0.97) and MT (β = 0.19). Reliability data for a mission of 50,000 cycles at 400 N revealed significant reliability differences between groups EH (97%), IH (46%) and MT (0.5%) but no significant difference at 200 N between EH (100%) and IH (98%), and IH and MT (89%). Weibull strength distribution (figure) revealed β = 13.1/η = 561.8 for EH, β = 5.8/η = 513.4 for IH and β = 5.3/η = 333.2 for MT. Groups EH and IH exhibited veneer cohesive and adhesive failures. Group IH also presented adhesive failure at zirconia/titanium abutment insert while MT showed fracture at abutment neck.SignificanceAlthough group EH presented higher reliability and characteristic strength followed by IH and MT, all groups withstood reported mean anterior loads.  相似文献   

9.
ObjectivesThe purpose of this study was to evaluate the bond strength of commercially pure CPTi and Ti6Al4V alloy with SiO2 and SiO2–TiO2 intermediate coatings to Triceram low-fusing dental porcelain.MethodsThe multilayered systems were characterized from the standpoint of microstructure analysis (SEM), the mode of failure, the nature of bonding and the influence of intermediate coatings on the improvement of bond strength. The SiO2 and SiO2–TiO2 intermediate coatings were applied on the substrate materials by the sol–gel dipping technique. The metal–ceramic bond strength was investigated according to ISO 9693 standards using the three-point flexure bond test.ResultsStatistically significant higher bond strength of the metal–porcelain for Ti6A14V alloy (28.24 MPa), Ti6Al4V/SiO2 (32.17 MPa) and Ti6Al4V/SiO2–TiO2 (36.09 MPa) was noted in comparison to CPTi (23.04 MPa), CPTi/SiO2 (27.98 MPa) and CPTi/SiO2–TiO2 (28.84 MPa), respectively. The nature of metal-intermediate coating–porcelain bonding was both mechanical and chemical. The failure in all systems was cohesive and adhesive, mainly adhesive.SignificanceThe application of SiO2 and SiO2–TiO2 intermediate coatings, produced by the sol–gel method, to both CPTi and Ti6Al4V alloy significantly improves the bond strength of metal–porcelain systems in comparison to the metal substrate only after sandblasting, and may have clinical use.  相似文献   

10.
《Dental materials》2019,35(12):1769-1775
ObjectiveTo compare shear bond strength (SBS) and interfacial fracture toughness (IKIC) results when assessing the effect of surface roughness and thermocycling on the adherence of a resin composite luting agent (RCLA) to a CAD/CAM resin composite block (RCB).MethodsTetric CAD HT along with the recommended bonding system, Adhese Universal and Variolink Esthetic LC, were used. Surface roughness was achieved with 600/320/60 grit SiC papers. Samples were stored 24 h in 37 °C water or thermocycled 10000× (5 °C–55 °C) prior to testing. Results were analyzed by univariate ANOVA and Scheffé modified t-tests (α = 0.05). Fractured specimens were viewed with a stereo microscope and selected specimens with a scanning electron microscope.ResultsSBS results showed a significant difference between the 60 grit group and the other groups, both after 24 h and thermocycling. A large number of SBS samples showed cohesive fracture or subsurface damage in RCB. Thermocycling led to a significant decrease in SBS in all groups. IKIC results showed no significant differences due to surface preparation after 24 h storage in 37 °C. After thermocycling, there was a significant difference between the 60 and the 600 grit groups. All KIC samples fractured adhesively at the RCB surface. KIC of the RCLA was significantly higher than IKIC of all groups.SignificanceThe results endorse the use of fracture mechanics methodology for the assessment and characterization of adherence, while identifying difficulties in its implementation. The results suggest also that adherence to CAD/CAM RCB may be limited by the strength of the resin composite block — adhesive interface.  相似文献   

11.
ObjectivesThe purpose of this work was to investigate the effects of layering techniques in resin composite restorations on the micro-tensile bond strength to the dentin of the occlusal cavity.MethodsHuman premolars were extracted and randomly divided into four groups. The occlusal enamel was then removed to expose a flat superficial dentin surface. Cavities 3.5 mm long and 3.5 mm wide were prepared to a depth 3 mm below the dentin surface. The adhesive Single Bond was applied according to the manufacturer's instructions. The teeth were then restored with Z100 resin composite as follows: Group 1 was restored in horizontal increments (three layers). Groups 2 and 3 were restored in different oblique increments (three layers). Group 4 was restored in oblique increments (four layers). After 24 h storage at 37 °C in water, all the teeth were sectioned to obtain bar-shaped specimens with a bonded surface area of approximately 0.9 mm × 0.9 mm. Dentin micro-tensile bond strength was measured at a crosshead speed of 0.5 mm/min. The results obtained were statistically analyzed using one-way ANOVA and SNK test at a significance level of P = 0.05. All fractures were then observed under a scanning electron microscope (SEM).ResultsThe results showed that there is a significant difference between the strength of the micro-tensile bonds to the dentin of occlusal cavities depending on which of the four layering restorative techniques was used (P < 0.01). SEM observation showed that failure patterns were most evidently interfacial cohesive failure.SignificanceLayering techniques in resin composite restorations affected the micro-tensile bond strength between the resin composite and the dentin. But the outcomes related to only Single Bond, as the same using other adhesives might have different outcomes.  相似文献   

12.
ObjectivesTo evaluate the hydrolytic stability of different dual-cure resin cements when luted to zirconia ceramic.MethodsEighteen cylinder-shaped zirconia blocks (Cercon Zirconia, Dentsply) were conditioned with: Group 1, no treatment; Group 2, sandblasting (125 μm alumina–Al2O3-particles); Group 3, tribochemical silica coating (50 μm silica-modified Al2O3 particles). Ceramic blocks were duplicated in composite resin (Tetric Evo Ceram, Ivoclar-Vivadent). Composite disks were luted to pre-treated ceramic surfaces using: (1) Clearfil Esthetic Cement (CEC; Kuraray); (2) Rely X Unicem (RXU; 3M ESPE); (3) Calibra (CAL; Dentsply Caulk). After 24 h, bonded samples were cut into microtensile sticks (1 mm2). Half of the sticks were loaded in tension until failure (cross-head speed of 0.5 mm/min). The remaining half was tested after 6 months of water storage at 37 °C. Data was analyzed with three-way ANOVA and Tukey’s test (P <0.05). Fractographic analysis was performed by SEM.ResultsAfter 24 h, bond strength of CEC to zirconia was significantly higher than that of RXU and CAL, independently from the ceramic pre-treatment (P <0.001). Using CAL, all samples failed prematurely except when luting to sandblasted surfaces. After 6 months of water aging, bond strength of CEC significantly decreased. RXU did not significantly alter bond strengths. Adhesion of sandblasted specimens luted with CAL fell over time. Micromorphological alterations were evident after water storage.SignificanceResin–ceramic interfacial longevity depended on cement selection rather than on surface pre-treatments. CEC and RXU were both suitable for luting zirconia. Water aging played an important role in the durability of zirconia-to-composite chemical bonds.  相似文献   

13.
ObjectivesThis study investigated the effect of extreme cooling methods on the flexural strength, reliability and shear bond strength of veneer porcelain for zirconia.MethodsVita VM9 porcelain was sintered on zirconia bar specimens and cooled by one of the following methods: inside a switched-off furnace (slow), at room temperature (normal) or immediately by compressed air (fast). Three-point flexural strength tests (FS) were performed on specimens with porcelain under tension (PT, n = 30) and zirconia under tension (ZT, n = 30). Shear bond strength tests (SBS, n = 15) were performed on cylindrical blocks of porcelain, which were applied on zirconia plates. Data were submitted to one-way ANOVA and Tukey's post hoc tests (p < 0.05). Weibull analysis was performed on the PT and ZT configurations.ResultsOne-way ANOVA for the PT configuration was significant, and Tukey's test revealed that fast cooling leads to significantly higher values (p < 0.01) than the other cooling methods. One-way ANOVA for the ZT configuration was not significant (p = 0.06). Weibull analysis showed that normal cooling had slightly higher reliability for both the PT and ZT configurations. Statistical tests showed that slow cooling decreased the SBS value (p < 0.01) and showed less adhesive fracture modes than the other cooling methods.Clinical SignificanceSlow cooling seems to affect the veneer resistance and adhesion to the zirconia core; however, the reliability of fast cooling was slightly lower than that of the other methods.  相似文献   

14.
《Dental materials》2014,30(10):e272-e282
ObjectivesThe temperature variations during the veneering firing cycles of a zirconia dental ceramic can negatively affect its mechanical properties. A possible synergistic effect of both heat-treatment and aging while exposed to the oral environment could result to catastrophic failure. The aim of the present study was to investigate the effect of heat treatment followed during veneering and in vitro aging on the mechanical and microstructural properties of zirconia dental ceramics.MethodsThree specimens from each of two zirconia blocks (Ivoclar IPS e.max ZirCAD (IV) and Wieland ZENO Zr (WI)) were cut by CAD/CAM technology, fully sintered and polished. Each one was cut in four equal parts. One part was used as control (C), one was heat-treated (H), one was aged (A) (134 °C, 2 bar, 10 h) and one was heat-treated and subsequently aged (HA). The mechanical properties (nano-hardness (H) and elastic modulus (E*)) were investigated by nano-indentation tests while the surface characterization was carried out with XRD, FTIR and SEM.ResultsDifferent treatments on IV and WI samples resulted in a reduction of both H and E* values, however the differences were not statistically significant (p > 0.05). The combination of treatments imposes an overall effect (p < 0.001), enhancing the influence on both H and E* values. This reduction in mechanical properties was followed by an increase of monoclinic content. Greater variations in both H and E* values were recorded for WI samples.SignificanceThe clinical performance of zirconia dental ceramics may be affected during firing and aging resulting in increased probability of failure.  相似文献   

15.
ObjectiveEtch and resin infiltration morphologies were compared for three self-etch adhesive (SEA) systems and eleven model etch-and-rinse (ERA) systems using various phosphoric acid (PA) concentrations with Adper Single Bond Plus (SB) adhesive. Matches for the morphologies were made between each SEA system and one of the PA/SB systems and bond strength measurements were made for all the systems. The hypothesis was that similar morphology would result in similar bond strength assuming micro-mechanical bonding is the mechanism of adhesion.MethodsThree specimens were prepared on polished (4000 grit) human enamel for each adhesive system to examine etch and resin infiltration morphology by SEM. For the latter, the adhesive systems were bonded using recommended methods and the enamel was dissolved in acid to reveal the resin. The etch patterns for the SEA systems were determined by rinsing off the material with water and acetone. Polished (4000 grit) human enamel was used with each adhesive system to determine 24-h resin composite to enamel shear bond strengths (SBS). A minimum of 10 specimens were used for each group. Data were analyzed by a one factor ANOVA and Fisher's PLSD post hoc test.ResultsThe SBS to polished enamel for two of the three SEA systems were statistically significantly greater (p < 0.05) than the PA/SB matched systems, indicating that chemical bonding might be partly responsible for the measured bond strength. All three SEA systems provided statistically lower (p < 0.05) SBS values than the PA/SB systems with PA concentrations between 2.5% and 40%.SignificanceAlthough chemical bonding may be present for some SEA systems it does not provide enough increase in bond strength to compete with the bond produced by ERA systems using phosphoric acid etching of enamel.  相似文献   

16.
ObjectiveBond strengths of composite resin to enamel using four self-etch adhesive (SEA) systems were compared with the bond strength of an etch-and-rinse adhesive (ERA) system, for both polished enamel and enamel pre-etched with phosphoric acid. The objective was to determine if the pre-etching would increase the bond strengths of the SEA systems to match the ERA system.MethodsTen specimens were used for each adhesive to determine 24-h resin composite to enamel shear bond strengths (SBS) to polished (4000 grit) human enamel and this was repeated for the SEA systems for enamel that was pre-etched with phosphoric acid for 15 s. SEM analysis was made to assess the degree of etching and resin penetration into enamel for each of the adhesive systems. Data were analyzed by a two factor ANOVA with a Tukey HSD post hoc test.ResultsThe SBS to polished enamel for all four SEA systems were statistically significantly lower (p < 0.05) than the ERA control, but with pre-etched enamel there were no statistically significant differences (p > 0.05) between any of the adhesive systems. All four of the SEA systems demonstrated statistically significant increases in bond strength between bonding to polished and pre-etched enamel, ranging from 27% to 86%. The results of SEM analysis showed no differences in the resin penetration patterns of any of the adhesives for enamel that was etched with phosphoric acid.SignificancePre-etching enamel may enhance the bond strength of SEA systems to values comparable with those found with ERA adhesive systems, which may improve their overall performance in clinical use.  相似文献   

17.
《Dental materials》2020,36(7):e241-e254
ObjectivesThe present study aimed to evaluate the bonding between three 3D printed custom tray materials and three elastomeric impression/adhesive systems using the peel test.MethodsTest blocks were 3D printed by three different technologies using Dental LT, FREEPRINT tray, and polylactide (PLA) tray materials. The reference test blocks were conventionally fabricated with Zeta Tray LC, a light-curing resin. The surface topographies of the four tray materials were investigated by scanning electron microscopy (SEM) analyses and roughness measurements. The peel bond strength between the four tray materials and three impression/adhesive systems, vinylsiloxanether (VSXE), vinyl polysiloxane (VPS), and polyether (PE), was measured (n = 12 per group). The peeling failure modes and rupture sites were identified microscopically.ResultsThe four tray materials featured different surface topographies. The peel bond strength was not significantly different with VSXE and PE, but PLA and the reference showed higher peel bond strength with VPS than the Dental LT and FREEPRINT tray (p < 0.05). The rupture site of adhesive failure in all groups was partly at the adhesive-impression material interface and partly within the adhesive but never at the adhesive-tray material interface.SignificanceThe 3D printed tray materials can achieve satisfactory chemical compatibility with the adhesives of VSXE, VPS, and PE. Surface topographies generated by the 3D printing technologies may affect bonding. Generally, 3D printed tray materials can provide clinically adequate bond strength with the elastomeric impression/adhesive systems. PLA is recommended for bonding with VPS when severe impression removal resistance is detected.  相似文献   

18.
《Dental materials》2020,36(5):687-697
ObjectivesThe purpose of this study was to synthesize chlorhexidine (CHX)-encapsulated aluminosilicate clay nanotubes (Halloysite®, HNTs) and to incorporate them into the primer/adhesive components of an etch-and-rinse adhesive system (SBMP; Scotchbond Multipurpose, 3M ESPE) and to test their effects on degree of conversion, viscosity, immediate and long-term bonding to dentin.MethodsCHX-modified HNTs were synthesized using 10% or 20% CHX solutions. The primer and the adhesive components of SBMP were incorporated with 15 wt.% of the CHX-encapsulated HNTs. Degree of conversion (DC) and viscosity analyses were performed to characterize the modified primers/adhesives. For bond strength testing, acid-etched dentin was treated with one of the following: SBMP (control); 0.2%CHX solution before SBMP; CHX-modified primers + SBMP adhesive; SBMP primer + CHX-modified adhesives; and SBMP primer + CHX-free HNT-modified adhesive. The microtensile bond strength test was performed after immediate (24 h) and long-term (6 months) of water storage. Data were analyzed using ANOVA and Tukey (α = 5%) and the Weibull analysis.ResultsDC was greater for the CHX-free HNT-modified adhesive, whereas the other experimental adhesives showed similar DC as compared with the control. Primers were less viscous than the adhesives, without significant differences within the respective materials. At 24 h, all groups showed similar bonding performance and structural reliability; whereas at the 6-month period, groups treated with the 0.2%CHX solution prior bonding or with the CHX-modified primers resulted in greater bond strength than the control and superior reliability.SignificanceThe modification of a primer or adhesive with CHX-encapsulated HNTs was an advantageous approach that did not impair the polymerization, viscosity and bonding performance of the materials, showing a promising long-term effect on resin-dentin bonds.  相似文献   

19.
ObjectivesThe purpose of this study was to evaluate the influence of thermal and mechanical cycling and veneering technique on the shear bond strength of Y-TZP (yttrium oxide partially stabilized tetragonal zirconia polycrystal) core–veneer interfaces.Materials and methodsCylindrical Y-TZP specimens were veneered either by layering (n = 20) or by pressing technique (n = 20). A metal ceramic group (CoCr) was used as control (n = 20). Ten specimens for each group were thermal and mechanical cycled and then all samples were subjected to shear bond strength in a universal testing machine with a 0.5 mm/min crosshead speed. Mean shear bond strength (MPa) was analysed with a 2-way analysis of variance and Tukey's test (p < 0.05). Failure mode was determined using stereomicroscopy and scanning electron microscopy (SEM).ResultsThermal and mechanical cycling had no influence on the shear bond strength for all groups. The CoCr group presented the highest bond strength value (p < 0.05) (34.72 ± 7.05 MPa). There was no significant difference between Y-TZP veneered by layering (22.46 ± 2.08 MPa) or pressing (23.58 ± 2.1 MPa) technique. Failure modes were predominantly adhesive for CoCr group, and cohesive within veneer for Y-TZP groups.ConclusionsThermal and mechanical cycling, as well as the veneering technique does not affect Y-TZP core–veneer bond strength.Clinical significanceDifferent methods of veneering Y-TZP restorations would not influence the clinical performance of the core/veneer interfaces.  相似文献   

20.
ObjectivesThe main reason for restoration failure is secondary caries caused by biofilm acids. Replacing the failed restorations accounts for 50–70% of all operative work. The objectives of this study were to incorporate a new quaternary ammonium monomer (dimethylaminododecyl methacrylate, DMADDM) and nanoparticles of silver (NAg) into a primer and an adhesive, and to investigate their effects on antibacterial and dentin bonding properties.MethodsScotchbond Multi-Purpose (SBMP) served as control. DMADDM was synthesized and incorporated with NAg into primer/adhesive. A dental plaque microcosm biofilm model with human saliva was used to investigate metabolic activity, colony-forming units (CFU), and lactic acid. Dentin shear bond strengths were measured.ResultsMinimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBC) of the new DMADDM were orders of magnitude lower than those of a previous quaternary ammonium dimethacrylate (QADM). Uncured primer with DMADDM had much larger inhibition zones than QADM (p < 0.05). Cured primer/adhesive with DMADDM-NAg greatly reduced biofilm metabolic activity (p < 0.05). Combining DMADDM with NAg in primer/adhesive resulted in less CFU than DMADDM alone (p < 0.05). Lactic acid production by biofilms was reduced by 20-fold via DMADDM-NAg, compared to control. Incorporation of DMADDM and NAg into primer/adhesive did not adversely affect dentin bond strength.ConclusionsA new antibacterial monomer DMADDM was synthesized and incorporated into primer/adhesive for the first time. The bonding agents are promising to combat residual bacteria in tooth cavity and invading bacteria at tooth-restoration margins to inhibit caries. DMADDM and NAg are promising for use into a wide range of dental adhesive systems and restoratives.  相似文献   