 共查询到20条相似文献,搜索用时 46 毫秒
1.
The purpose of this study was to investigate the diagnostic performance of the automated breast ultrasound system (ABUS) compared with hand-held ultrasonography (HHUS) and mammography (MG) for breast cancer in women aged 40 y or older. A total of 594 breasts in 385 patients were enrolled in the study. HHUS, ABUS and MG exams were performed for these patients. Follow-up and pathologic findings were used as the reference standard. Based on the reference standard, 519 units were benign or normal and 75 were malignant. The sensitivity, specificity, accuracy and Youden index were 97.33%, 89.79%, 90.74% and 0.87 for HHUS; 90.67%, 92.49%, 92.26% and 0.83 for ABUS; 84.00%, 92.87%, 91.75% and 0.77 for MG, respectively. The specificity of ABUS was significantly superior to that of HHUS (p = 0.024). The area under the receiver operating characteristic curve was 0.936 for HHUS, which was the highest, followed by 0.916 for ABUS and 0.884 for MG. However, the difference was not statistically significant (p > 0.05). In conclusion, the diagnostic performance of ABUS for breast cancer was equivalent to HHUS and MG and potentially can be used as an alternative method for breast cancer diagnosis.  相似文献   

2.
3.
New automated whole breast ultrasound (ABUS) machines have recently been developed and the ultrasound (US) volume dataset of the whole breast can be acquired in a standard manner. The purpose of this study was to develop a novel computer-aided diagnosis system for classification of breast masses in ABUS images. One hundred forty-seven cases (76 benign and 71 malignant breast masses) were obtained by a commercially available ABUS system. Because the distance of neighboring slices in ABUS images is fixed and small, these continuous slices were used for reconstruction as three-dimensional (3-D) US images. The 3-D tumor contour was segmented using the level-set segmentation method. Then, the 3-D features, including the texture, shape and ellipsoid fitting were extracted based on the segmented 3-D tumor contour to classify benign and malignant tumors based on the logistic regression model. The Student’s t test, Mann-Whitney U test and receiver operating characteristic (ROC) curve analysis were used for statistical analysis. From the Az values of ROC curves, the shape features (0.9138) are better than the texture features (0.8603) and the ellipsoid fitting features (0.8496) for classification. The difference was significant between shape and ellipsoid fitting features (p = 0.0382). However, combination of ellipsoid fitting features and shape features can achieve a best performance with accuracy of 85.0% (125/147), sensitivity of 84.5% (60/71), specificity of 85.5% (65/76) and the area under the ROC curve Az of 0.9466. The results showed that ABUS images could be used for computer-aided feature extraction and classification of breast tumors. (E-mail: rfchang@csie.ntu.edu.tw)  相似文献   

4.
This prospective study investigated the usefulness of contrast (perfluorobutane-containing microbubbles)-enhanced ultrasound in the non-invasive assessment of liver allograft damage. Forty-one liver recipients underwent contrast-enhanced ultrasound followed by a liver biopsy. The hepatic filling rate (time between the arrival of contrast agent in the right hepatic artery and the maximum intensity of hepatic parenchyma) and parenchymal intensity difference before and after instantaneous high-power emission in the Kupffer phase were measured. Patients with allograft damage had higher hepatic filling rates and lower parenchymal intensity differences than those without damage (42.0 ± 16.9 vs. 30.5 ± 7.7 s, p = 0.005; 6.1 ± 7.4 vs. 16.6 ± 16.1 dB, p = 0.047, respectively). In the diagnosis of liver allograft damage, hepatic filling rate and parenchymal intensity difference had sensitivities of 61.5% and 90.9% and specificities of 92.6% and 63.6% using cutoffs of >38.5 s and ≤10.3 dB, respectively. In conclusion, contrast-enhanced ultrasound may be a promising tool in the detection of liver allograft damage.  相似文献   

5.
Radiotherapy (RT) in the thoracic region is associated with an increased risk of late cardiovascular morbidity and mortality. Ultrasonic tissue characterisation (UTC) is a non-invasive method of identifying changes in myocardial tissue, such as increased fibrosis. The aim of this study was to assess whether UTC can detect early RT-induced myocardial alterations. Seventy-eight eligible patients with early stage breast cancer were evaluated before and immediately after RT. Twenty patients had right-sided and 58 left-sided breast cancer. None received chemotherapy. A comprehensive echocardiographic examination included 3D measurements and UTC of the right ventricular (RV) free wall, ventricular septum and left ventricular (LV) posterior wall. Integrated backscatter calibration was done for the pericardium (cpIBS) and LV cavity (ccIBS). RT for left-sided breast cancer was associated with increased echodensity in the UTC analysis. RV free wall and ventricular septum cpIBS increased from ?15.0 ± 7.3 to ?13.7 ± 7.9 dB (p = 0.079) and from ?18.2 ± 5.1 to -16.0 ± 6.4 dB (p = 0.002), respectively. Likewise, ccIBS in the RV free wall increased from 20.4 ± 5.9 to 22.1 ± 5.6 dB (p = 0.046), and in the LV septum from 17.3 ± 5.2 to 19.8 ± 5.5 dB (p < 0.001). In 3D echocardiography, LV mass increased from 102 ± 18 to 107 ± 18 g (p = 0.005). Patients receiving RT for right-sided breast cancer did not display these changes. Left-sided RT increased myocardial echodensity, particularly in the structures receiving the highest radiation dose. Considering the progressive nature of the RT induced damage, these early changes may help us with individual risk stratification and serve as a tool for screening.  相似文献   

6.
ObjectiveIn this study we aimed to evaluate the operation times of ABUS by technologists during the learning time course and share the learning experience.Materials and methodThe first consequent 400 examinations after the installation of an ABUS unit in the breast clinic between August 2017 and December 2017 were included. Total examination time was measured for each procedure. The initial and final examination times during the learning period were compared. Data were analyzed with the Mann-Whitney Test.ResultsThe acquisition times for routine six position examination ranged between eight and 36 minutes with an average of 13.2 ± 3.58 min. The examination time for the eight position examination ranged between 18 and 32 min, with an average of 22.9 ± 3.93 min. The overall average examination time was 13.3 ± 3.98 min. There was a significant difference (p = 0.00) between the average initial and final examination times of the learning period with an average decrease of 10.6 min.ConclusionThe average time of an ABUS examination for an average breast is less than 15 min. ABUS examination time reduced as technologists became familiar with the sonographic anatomy of the breast and experienced in positioning technique during the learning curve.  相似文献   

7.
This work investigates the application of a deformable localization/mapping method to register lesions between the digital breast tomosynthesis (DBT) craniocaudal (CC) and mediolateral oblique (MLO) views and automated breast ultrasound (ABUS) images. This method was initially validated using compressible breast phantoms. This methodology was applied to 7 patient data sets containing 9 lesions. The automated deformable mapping algorithm uses finite element modeling and analysis to determine corresponding lesions based on the distance between their centers of mass (dCOM) in the deformed DBT model and the reference ABUS model. This technique shows that location information based on external fiducial markers is helpful in the improvement of registration results. However, use of external markers are not required for deformable registration results described by this methodology. For DBT (CC view) mapped to ABUS, the mean dCOM was 14.9 ± 6.8 mm based on 9 lesions using 6 markers in deformable analysis. For DBT (MLO view) mapped to ABUS, the mean dCOM was 13.7 ± 6.8 mm based on 8 lesions using 6 markers in analysis. Both DBT views registered to ABUS lesions showed statistically significant improvements (p ≤ 0.05) in registration using the deformable technique in comparison to a rigid registration. Application of this methodology could help improve a radiologist's characterization and accuracy in relating corresponding lesions between DBT and ABUS image datasets, especially for cases of high breast densities and multiple masses.  相似文献   

8.
The aim of the study described here was to evaluate the feasibility and accuracy of measuring endotracheal tube (ETT) depth with ultrasound in adult patients in an intensive care unit (ICU). The distance between the upper margin of the cuff and the upper margin of the aortic arch (Duc-ua) of 67 ICU patients was measured by ultrasound, and the time of measurement was recorded. The level of agreement between the distance between the tip of the ETT and the carina (Dtt-c) measured by ultrasound (U-Dtt-c) and Dtt-c measured by bronchoscopy (B-Dtt-c) was assessed using linear regression and a Bland–Altman plot. There was a significant correlation between B-Dtt-c and U-Dtt-c (r = 0.844, p < 0.001). Also, the Bland–Altman plot revealed strong agreement between B-Dtt-c and U-Dtt-c. The time it took to measure ETT depth by ultrasound was 33.91 ± 5.43 s. In conclusion, bedside ultrasound provides a novel and convenient method for measuring the depth of ETT in ICU patients.  相似文献   

9.
We investigated the correlation between hepatic venous pressure gradient (HVPG) and liver shear wave speed (SWS) measured by multi-frequency time-harmonic ultrasound elastography (THE) before and after transjugular intrahepatic portosystemic shunt (TIPS) implantation. Ten patients with ascites, cirrhotic liver disease and portal hypertension were prospectively examined with invasive HVPG measurement and THE before and after TIPS implantation. HVPG and SWS decreased after TIPS placement from 20.4 ± 2.2 mmHg to 9.8 ± 4.1 mmHg (mean ± standard deviation) and from 3.87 ± 0.54 m/s to 3.27 ± 0.44 m/s. Mean reduction HVPG was ?10.6 ± 3.7 mmHg, p < 0.001; mean reduction SWS was ?0.60 ± 0.29 m/s, p < 0.001. A linear correlation was observed between HVPG and SWS (R = 0.59, p = 0.0061). THE-measured SWS is a first potential direct ultrasound marker for liver decompression following TIPS in ascites-associated cirrhotic liver disease and therefore might be suitable to non-invasively detect portal hypertension.  相似文献   

10.
Discriminating between causes of dyspnea may be difficult, particularly in the elderly. The aim of this retrospective study of 83 inpatients with acute dyspnea was to assess the influence of age, multimorbidity and cognitive or motor impairment on the diagnostic accuracy of lung ultrasound (LUS) in discriminating acute heart failure (AHF) from noncardiogenic dyspnea (NCD). Univariate analysis indicates that LUS misdiagnosis was associated with the following parameters: history of stroke (p = 0.037), lower activity of daily living (p = 0.039), higher modified-Rankin scale (mRS) (p = 0.027) and need of two operators to complete LUS because of reduced patient compliance (p = 0.030). Regression analysis identified only history of stroke (p = 0.048) as an independent predictor of LUS misdiagnosis. This study supports LUS usefulness to differentiate AHF from NCD. Our data suggest that diagnostic accuracy of LUS is affected by history of stroke as a proxy for severe motor impairment but not by age, cognitive impairment and multimorbidity.  相似文献   

11.
Pompe’s disease is a glycogen storage disease (type II) characterized by inherited autosomal recessive transmission. The right ventricular (RV) function is a determinant parameter of clinical outcome in patients with heart failure. We sought to characterize the RV function using Doppler-echocardiography completed by Doppler tissular imaging and tricuspid annular plane systolic excursion (TAPSE) measurement. We analyzed retrospectively clinical and Doppler-echocardiographic data of patients with adult late onset Pompe disease and compared to a control group. Ten patients with late onset Pompe disease were included in our study and were compared to a control group (seven patients). Mean age was 56.7 ± 10.2 years in late onset Pompe disease versus 55 ± 21 years in control group (p  = 0.65). Left ventricular ejection fraction (LVEF) was similar in the two groups (LVEF 63.7 ± 9 vs 63.7 ± 6.6 % in control group p  = 0.99). LV end diastolic diameter was 40.8 ± 6 mm in Pompe disease versus 45.8 ± 6 mm in control group (p  = 0.11). Mean TAPSE was similar in the two groups (25.6 ± 6.2 vs 21.5 ± 2.7 mm p = 0.23). Mean peak systolic RV velocity Sm was not significantly different in the two groups (17.11 ± 3.4 cm/s in Pompe disease vs 16.14 ± 3.8 cm/s in control group p = 0.61). Mean peak early diastolic Ea velocity in the RV were not significantly different in the two groups (15.6 ± 5.6 vs 18.2 ± 4.9 cm/s p = 0.34). According to our data, RV systolic function seems preserved in late-onset Pompe disease.  相似文献   

12.
This study evaluated the usefulness of magnetic resonance (MR)-navigated ultrasound (US) for evaluation of magnetic resonance imaging (MRI)-detected lesions not visible on second-look US and analyzed differences in lesion-to-nipple distance between supine and prone positions. Of the 831 consecutive patients who were diagnosed with breast cancer and examined with breast MRI from June 2013 to September 2015, 40 lesions in 37 patients who underwent MR-navigated US for MRI-detected lesions that were not visible on second-look US were included. First, MRI was performed in a prone position using a 1.5-T imager, and second, MRI was performed in a supine position for MR-navigated US. Of 40 lesions, 31 (78%) were identified with MR-navigated US, whereas 5 (13%) lesions disappeared on supine MRI and 4 (10%) exhibited no correlation on MR-navigated US. Of 31 lesions with pathologic confirmation, 7 (23%) were malignant, 2 (6%) were high-risk lesions and 22 (71%) were benign lesions. Comparison of the US findings of benign and malignant lesions revealed that orientation of the lesion differed significantly (p = 0.045), whereas lesion shape, margin and echo pattern did not significantly differ between the two groups (p = 0.088, p = 0.094 and p = 0.412, respectively). Median difference in lesion-to-nipple distance on supine and prone MRI was 8 mm (0–34 mm) in the horizontal direction and 5 mm (0–39.5 mm) in the vertical direction. Thirteen lesions exhibited a >1-cm difference in both horizontal and vertical directions. In conclusion, MR-navigated US was useful for the evaluation of MRI-detected lesions that were not visible on second-look US in breast cancer patients.  相似文献   

13.
The automated volume scanning system (AVSS) has been applied in breast diseases, but its use in incisional hernias has not been reported. In this study, conventional handheld B-mode ultrasound (HHUS) and AVSS examined a total of 122 hernia defects in 78 patients. The results from two modalities were then compared with surgical findings for the purpose of assessing the diagnostic value of AVSS. Statistics showed that surgeries identified 38 small, 23 medium and 17 large incisional hernias. The results of AVSS completely agreed with surgical findings; however, HHUS misidentified nine large hernias as medium and seven medium hernias as large. AVSS proved to be more accurate than HHUS in measuring the length and width of the hernia. It also outperformed HHUS in both detecting the incisional hernias (91.8% vs. 78.7%, p = 0.00) and determining hernia contents (89.3% vs. 68.0%, p = 0.00). Moreover, the coronal images AVSS obtained clearly displayed the shapes of the hernias, with 46 being regular and 32 irregular. Overall, AVSS can be used as a promising diagnostic modality for incisional hernias.  相似文献   

14.
Lumen dimensions measured by time-domain optical coherence tomography (TD-OCT) may be influenced by the hemodynamic effect of proximal balloon occlusion. Frequency-domain OCT (FD-OCT) does not require the interruption of blood flow. Therefore, we compared the coronary lumen dimensions measured by TD-OCT, FD-OCT, and intravascular ultrasound (IVUS) in both stented and non-stented segments. Twenty patients who underwent both IVUS and OCT imaging (10 for TD- and 10 for FD-OCT) after stent implantation were included. The maximum, minimum, and mean diameters and areas were measured at the proximal and distal stent edges, as well as 3 mm inside and 5 mm outside of both edges. The measurements inside stent showed no significant differences between IVUS and TD- or FD-OCT. The lumen mean diameters and areas measured by IVUS at 5 mm outside stent were similar to those measured by FD-OCT (Distal; 3.07 ± 0.7 vs 3.03 ± 0.7 mm, p = 0.08 and 7.80 ± 4.0 vs 7.72 ± 4.1 mm2, p = 0.07, respectively. Proximal; 3.25 ± 0.7 vs 3.23 ± 0.7 mm, p = 0.09 and 8.78 ± 3.8 vs 8.65 ± 3.7 mm2, p = 0.08, respectively), but were greater than those measured by TD-OCT (Distal; 2.75 ± 0.5 vs 2.29 ± 0.5 mm, p = 0.0001 and 6.15 ± 2.6 vs 4.38 ± 1.9 mm2, p = 0.0002, respectively. Proximal; 3.27 ± 0.6 vs 2.69 ± 0.6 mm, p = 0.0001 and 8.64 ± 3.4 vs 6.12 ± 2.7 mm2, p = 0.0001 respectively). The interaction between TD- and FD-OCT for lumen dimension measurements at 5 mm outside stent was statistically significant. Vessel dimension measurements were similar between IVUS and FD-OCT in native vessel unlike with TD-OCT. Therefore, we might adapt the IVUS criteria of lesion severity for percutaneous coronary intervention to FD-OCT.  相似文献   

15.
We prospectively evaluated the feasibility of using ultrasound strain imaging (USI) to assess biceps brachii muscle (BBM) stiffness and dynamic motion in 10 healthy adults. The BBM axial deformation was produced by external compression with a sandbag (1.0 kg) tied onto the transducer. The BBM lateral movement was produced by manual passive elbow flexion and extension. By use of 2-D speckle tracking, captured 5-s real-time ultrasound data of BBM were processed to estimate axial strain, representing muscle stiffness, and lateral strain and tissue velocity, representing muscle dynamic motion. Axial (lateral) strain ratio was defined as BBM strain divided by subcutaneous soft tissue strain. There was no significant difference in lateral strain or tissue velocity between the left and right BBM (lateral strain ratio: 4.69 ± 0.07 vs. 4.51 ± 0.08 for extension, 4.82 ± 0.09 vs. 4.69 ± 0.11 for flexion; tissue velocity: 1.58 ± 0.32 cm/s vs. 1.78 ± 0.85 cm/s for extension, ?2.03 ± 0.63 vs. ?2.03 ± 0.59 for flexion; all p values > 0.05) or between men and women (lateral strain ratio: 4.52 ± 0.06 vs. 4.67 ± 0.1 for extension, 4.71 ± 0.11 vs. 4.83 ± 0.09 for flexion; tissue velocity, cm/s: 1.76 ± 0.76 vs. 1.66 ± 0.65 for extension, ?2.21 ± 0.65 vs. ?1.88 ± 0.52 for flexion, all p values > 0.05). The difference in axial stain between men and women was significant (axial strain ratio: 3.09 ± 0.43 vs. 3.52 ± 0.26, p = 0.02). Inter- and intra-observer reliability in performing USI of the BBM was good (all intra-class correlation coefficients [ICCs] >0.75). Our results suggest that USI seems to be feasible for and reproducible in estimating BBM mechanical properties and motion dynamics in healthy adults.  相似文献   

16.
To evaluate the diagnostic performance of automated breast ultrasound (ABUS) after breast magnetic resonance imaging (MRI) as a replacement for hand-held second-look ultrasound (HH-SLUS), we evaluated 58 consecutive patients with breast cancer who had additional suspicious lesions on breast MRI. All patients underwent HH-SLUS and ABUS. Three breast radiologists evaluated the detectability, location, characteristics and conspicuity of lesions on ABUS. We also evaluated inter-observer variability and compared the results with HH-SLUS results. Eighty additional suspicious lesions were identified on breast MRI. Fifteen of the 80 lesions (19%) were not detected on HH-SLUS. Eight of the 15 lesions (53%) were detected on ABUS, whereas the remaining 7 were not detected on ABUS. Among the 65 lesions detected on HH-SLUS, only 3 lesions were not detected on ABUS. The intra-class correlation coefficients for lesion location and size all exceeded 0.70, indicating high reliability. Moderate to fair agreement was found for mass shape, orientation, margin and Breast Imaging Reporting and Data System (BI-RADS) final assessment. Therefore, ABUS can reliably detect additional suspicious lesions identified on breast MRI and may help in the decision on biopsy guidance method (US vs. MRI) as a replacement tool for HH-SLUS.  相似文献   

17.
This study was designed to compare neointimal hyperplasia and peri-stent arterial remodeling after implantation of everolimus-eluting stent (EES) versus sirolimus-eluting stent (SES) using intravascular ultrasound (IVUS). The study population was a subgroup of 278 patients from the EXCELLENT trial, a randomized study comparing EES to SES in de novo coronary artery lesions (total n = 1,443, 3:1 randomization) who underwent post-PCI and 9-month follow-up IVUS evaluation. There were 209 patients in the EES group and 69 in the SES group. Baseline clinical and angiographic characteristics were similar between the two groups except for age and target lesion locations. At 9 months, percent neointimal volume obstruction did not differ between EES and SES (2.6 ± 4.0 % vs. 2.5 ± 4.8 %, p = 0.814). However, the relative change in the vessel (4.3 ± 13.7 % vs. 8.8 ± 18.6 %, p = 0.030) and plaque volume index (4.2 ± 17.4 % vs. 10.5 ± 22.3 %, p = 0.016) of the stented segment from post-intervention to follow-up was significantly less with EES than with SES. In addition, positive peri-stent vascular remodeling defined as an increase in vessel volume index >10 % (27.8 vs. 42.0 %, p = 0.027) and late acquired stent malapposition (LASM, 1.9 vs. 15.9 %, p < 0.001) were observed less frequently with EES than SES. EES and SES were similarly effective in reducing neointimal hyperplasia. However, positive peri-stent vascular remodeling and LASM occurred less frequently with EES than SES.  相似文献   

18.
The aim of the present study was to evaluate the applicability of ultrasound imaging to quantitative assessment of human meniscus in vitro. Meniscus samples (n = 26) were harvested from 13 knee joints of non-arthritic human cadavers. Subsequently, three locations (anterior, center and posterior) from each meniscus were imaged with two ultrasound transducers (frequencies 9 and 40 MHz), and quantitative ultrasound parameters were determined. Furthermore, partial-least-squares regression analysis was applied for ultrasound signal to determine the relations between ultrasound scattering and meniscus integrity. Significant correlations between measured and predicted meniscus compositions and mechanical properties were obtained (R2 = 0.38–0.69, p < 0.05). The relationship between conventional ultrasound parameters and integrity of the meniscus was weaker. To conclude, ultrasound imaging exhibited a potential for evaluation of meniscus integrity. Higher ultrasound frequency combined with multivariate analysis of ultrasound backscattering was found to be the most sensitive for evaluation of meniscus integrity.  相似文献   

19.
We investigated the feasibility of estimating absolute tissue blood perfusion using dynamic contrast-enhanced ultrasound (CEUS) imaging in mice. We developed a novel method of microbubble administration and a model-free approach to estimate absolute kidney perfusion, and explored the kidney as a reference organ to estimate absolute perfusion of a neuroblastoma tumor. We performed CEUS on the kidneys of CD1 nude mice using the VisualSonics VEVO 2100 imaging system. We estimated individual kidney blood perfusion using the burst–replenishment (BR) technique. We repeated the kidney imaging on the mice after a week. We performed CEUS imaging of a neuroblastoma mouse xenograft tumor along with its right kidney using two sets of microbubble administration parameters to estimate absolute tumor blood perfusion. We performed statistical tests at a significance level of 0.05. Our estimated absolute kidney perfusion (425 ± 123 mL/min/100 g) was within the range of previously reported values. There was no statistical difference between the estimated absolute kidney blood perfusions from the 2 wk of imaging (paired t-test, p = 0.09). We estimated the absolute blood perfusion in the neuroblastoma tumor to be 16.49 and 16.9 mL/min/100 g for the two sets of microbubble administration parameters (Wilcoxon rank-sum test, p = 0.6). We have established the kidney as a reliable reference organ in which to estimate absolute perfusion of other tissues. Using a neuroblastoma tumor, we have determined the feasibility of estimating absolute blood perfusion in tissues using contrast-enhanced ultrasound imaging.  相似文献   

20.
The goal of the study described here was to compare the accuracy of an automated breast volume scanner (ABVS) with that of hand-held ultrasound (HHUS) in assessing the pre-operative extent of pure ductal carcinoma in situ (DCIS). This prospective study consisted of 33 patients with histopathologically proven pure DCIS who received conventional HHUS and ABVS examinations. The discrepancy and correlation coefficients were calculated to assess differences in sizes determined by imaging and histopathologic examination. Mean age was 51.8 y. Mean lesion size as assessed with the ABVS did not differ significantly from that determined by histopathology. Lesion size was adequately estimated, under-estimated or over-estimated with the ABVS in 64%, 15% and 21% of patients, and with HHUS in 42%, 15% and 42%, respectively (p < 0.05). The coefficient of correlation between histopathologic and ABVS measurements was higher than that between histopathologic and HHUS measurements. The ABVS appears to assess the extent of the lesion better than HHUS and can provide more accurate information pre-operatively.  相似文献   