相似文献
 共查询到20条相似文献,搜索用时 248 毫秒
1.
We retrospectively compared detection rates and consistency for diagnosis of peritoneal carcinomatosis (PC) of primary ovarian cancer (OC) between ultrasound (US) and computed tomography (CT) scans in 41 patients whose PC of OC (stages IIC–IV) had been diagnosed by histopathology findings. Compared with CT detection rates, those for US were significantly higher for metastases to the pelvic area (92.3% vs. 43.6%, p < 0.001) and bowel surface (64.0% vs. 16.0%, p = 0.002); however, they did not significantly differ for other sites: omentum, diaphragm, lateral peritoneum, mesenteric, hepatic and splenic surfaces. Diagnostic consistency between US and CT scans were fair to moderate for splenic (κ = 0.806), hepatic (κ = 0.485), lateral peritoneum (κ = 0.450) and diaphragm (κ = 0.338) surfaces, but poorly consistent for other parts (κ = 0.144–0.229). In summary, US can complement CT scans, especially for detecting PC of primary OC metastases in pelvic and bowel surfaces.  相似文献   

2.

Purpose

To investigate the presentation of splenic hamartomas (SHs) on ultrasonography (US), CT and MRI.

Methods

Nine patients (5 males and 4 females, mean age, 52.8 years) with pathologically proven SHs were included in this study. US, CT and MRI images were analyzed retrospectively, and imaging features were correlated with pathological findings.

Results

SHs appeared solitary lesion (n = 8) and multiple lesions (n = 1) in the present study. (1) In 8 cases of solitary lesion, the lesions appeared as solid nodules or masses with well-defined margins and varying echogenicity (hyperecho = 5, hypoecho = 2, strong echo = 1) on ultrasound. The lesions showed iso-attenuation (n = 3) or slightly hypo-attenuation (n = 4) on unenhanced CT, and calcification were revealed in 3 lesions. MRI showed isointensity (n = 3) or hypointensity (n = 2) on the T1-weighted image, and heterogeneous hypointensity (n = 2), slightly hyperintensity (n = 2) and hyperintensity (n = 1) on the T2-weighted image. The enhanced patterns of SHs showed mild diffuse heterogeneous enhancement (n = 6) and prominent enhancement (n = 1) during arterial phase and above 7 lesions were demonstrated progressive enhancement at delayed phase on enhanced CT. One lesion without any enhancement was revealed in another patient. (2) One case of multiple lesions included 1 cystic lesion with irregular calcification and 7 solid lesions with progressive enhancement on CT images.

Conclusions

Combination of a variety of imaging modalities could more fully reflect the pathological characteristics and contribute to the diagnosis of SH.  相似文献   

3.

Objective

To compare imaging findings of CT and contrast-enhanced US (CEUS) in hepatic angiomyolipoma (HAML) and investigate their pathological correlations.

Methods

Imaging findings and preoperative diagnosis of CT and CEUS were retrospectively compared head to head in 46 patients with 54 histologically proven HAMLs. Correlations between imaging features and preoperative diagnosis with pathological types of HAMLs were analyzed.

Results

Fat was detected in 100% of lipomatous type, 84.6% of mixed type, and 7.1% of myomatous type (p = 0.000) of HAML at unenhanced CT. Well-defined hyper-echogenicity was displayed in 100% of lipomatous type, 88.5% of mixed type, 50% of myomatous type, and 66.7% of angiomatous type of HAMLs at unenhanced US. More arterial hyper-enhancement was noted on CEUS (100%) than on CT (73.1%) in mixed type (p = 0.015) and in lipomatous type (90.9% vs. 9.1%, p = 0.000) of HAMLs. Washout was present in more HAMLs on CT than on CEUS (42.6% vs. 18.5%, p = 0.007). Correct preoperative diagnosis was suggested in more HAMLs of myomatous type on CEUS than on CT (42.9% vs. 0%, p = 0.016) but showed no difference in other types of HAMLs.

Conclusion

There are considerable discrepancies between CT and CEUS findings of HAMLs, and the imaging appearance and preoperative diagnosis of HAMLs on CT and CEUS are significantly affected by pathological types of HAMLs.
  相似文献   

4.
To compare the image quality of coronary CT angiography (CTA) studies between standard filtered back projection (FBP) and adaptive iterative dose reduction in three-dimensions (AIDR3D) reconstruction using CT noise additional software to simulate reduced radiation exposure. Images from 93 consecutive clinical coronary CTA studies were processed utilizing standard FBP, FBP with 50 % simulated dose reduction (FBP50 %), and AIDR3D with simulated 50 % dose reduction (AIDR50 %). Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were measured within 5 regions-of-interest, and image quality for each reconstruction strategy was assessed by two independent readers using a 4-point scale. Compared to FBP, the SNR measured from the AIDR50 % images was similar or higher (airway: 38.3 ± 12.7 vs. 38.5 ± 14.5, p = 0.81, fat: 5.5 ± 1.9 vs. 5.4 ± 2.0, p = 0.20, muscle: 3.2 ± 1.2 vs. 3.1 ± 1.3, p = 0.38, aorta: 22.6 ± 9.4 vs. 20.2 ± 9.7, p < 0.0001, liver: 2.7 ± 1.0 vs. 2.3 ± 1.1, p < 0.0001), while the SNR of the FBP50 % images were all lower (p values < 0.0001). The CNR measured from AIDR50 % images was also higher than that from the FBP images for the aorta relative to muscle (20.5 ± 9.0 vs. 18.3 ± 9.2, p < 0.0001). The interobserver agreement in the image quality score was excellent (κ = 0.82). The quality score was significantly higher for the AIDR50 % images compared to the FBP images (3.6 ± 0.6 vs. 3.3 ± 0.7, p = 0.004). Simulated radiation dose reduction applied to clinical coronary CTA images suggests that a 50 % reduction in radiation dose can be achieved with adaptive iterative dose reduction software with image quality that is at least comparable to images acquired at standard radiation exposure and reconstructed with filtered back projection.  相似文献   

5.
This study evaluated the usefulness of magnetic resonance (MR)-navigated ultrasound (US) for evaluation of magnetic resonance imaging (MRI)-detected lesions not visible on second-look US and analyzed differences in lesion-to-nipple distance between supine and prone positions. Of the 831 consecutive patients who were diagnosed with breast cancer and examined with breast MRI from June 2013 to September 2015, 40 lesions in 37 patients who underwent MR-navigated US for MRI-detected lesions that were not visible on second-look US were included. First, MRI was performed in a prone position using a 1.5-T imager, and second, MRI was performed in a supine position for MR-navigated US. Of 40 lesions, 31 (78%) were identified with MR-navigated US, whereas 5 (13%) lesions disappeared on supine MRI and 4 (10%) exhibited no correlation on MR-navigated US. Of 31 lesions with pathologic confirmation, 7 (23%) were malignant, 2 (6%) were high-risk lesions and 22 (71%) were benign lesions. Comparison of the US findings of benign and malignant lesions revealed that orientation of the lesion differed significantly (p = 0.045), whereas lesion shape, margin and echo pattern did not significantly differ between the two groups (p = 0.088, p = 0.094 and p = 0.412, respectively). Median difference in lesion-to-nipple distance on supine and prone MRI was 8 mm (0–34 mm) in the horizontal direction and 5 mm (0–39.5 mm) in the vertical direction. Thirteen lesions exhibited a >1-cm difference in both horizontal and vertical directions. In conclusion, MR-navigated US was useful for the evaluation of MRI-detected lesions that were not visible on second-look US in breast cancer patients.  相似文献   

6.

Objective

To describe the CT findings of lymphoepithelial cysts (LECs) of the pancreas and to investigate the differential findings between LECs and other pancreatic cystic lesions.

Materials and methods

Fifty-eight patients with 8 LECs (M:F = 7:1; mean age 55.1 years), 30 serous cystadenomas (SCA) (M:F = 11:19; 52.5 years), 11 mucinous cystadenomas (MCA) (M:F = 0:11; 47.2 years), and 9 pseudocysts (M:F = 6:3; 50.8 years) were included in this study. Two radiologists analyzed all CT images for 3D location, outer shape, appearance, the presence of calcification, enhancing nodule, and pancreatic duct dilatation. Size of lesions and CT number of cystic portion on precontrast CT were measured. For statistical analysis, Mann–Whitney U test and Fisher’s exact test were used.

Results

75 % (6/8) of LECs showed an extrapancreatic location than all other cystic diseases in terms of 3D location (p < 0.0001). LECs showed variable outer shape without a significant difference from that of SCAs and pseudocysts (p > 0.05), but LECs showed microlobulated surface more frequently than the MCAs (p < 0.05). LECs showed a variable appearance from unilocular to multi-microcystic. CT attenuation of LECs (21.2 ± 7.1 HU) was higher than that of SCAs and MCAs (p = 0.005). Size of LECs (34.0 ± 10.8 mm) was smaller than that of MCAs (p = 0.040). There was no calcification, pancreatic duct dilatation, or enhancing nodules in LECs.

Conclusion

LECs appear as a highly exophytic medium-sized cystic mass with various morphology occurring predominantly in the middle-aged or older male patients.  相似文献   

7.
To systematically investigate into the relationships between luminal enhancement, convolution kernel, plaque density, and stenosis severity in coronary computed tomography (CT) angiography. A coronary phantom including 63 stenoses (stenosis severity, 10–90 %; plaque densities, ?100 to 1,000 HU) was loaded with increasing solutions of contrast material (luminal enhancement, 0–700 HU) and scanned in an anthropomorphic chest. CT data was acquired with prospective triggering using 64-section dual-source CT; reconstructions were performed with soft-tissue (B26f) and sharp convolution kernels (B46f). Two blinded and independent readers quantitatively assessed luminal diameter and CT number of plaque using electronic calipers. Measurement bias between phantom dimensions and CT measurements were calculated. Multivariate linear regression models identified predictors of bias. Inter- and intra-reader agreements of luminal diameter and CT number measurements were excellent (ICCs > 0.91, p < 0.01, each). Measurement bias of luminal diameter and plaque density was significantly (p < 0.01, each) lower (?12 % and 58 HU, respectively) with B46f as opposed to B26f, especially in plaque densities >200 HU. Measurement bias was significantly (p < 0.01, each) correlated (ρ = 0.37–55 and ρ = ?0.70–85) with the differences between luminal enhancement and plaque density. In multivariate models, bias of luminal diameter assessment with CT was correlated with plaque density (β = 0.09, p < 0.05). Convolution kernel (β = ?0.29 and ?0.38), stenosis severity (β = ?0.45 and ?0.38), and luminal enhancement (β = ?0.11 and ?0.29) represented independent (p < 0.05,each) predictors of measurement bias of luminal diameter and plaque number, respectively. Significant independent relationships exist between luminal enhancement, convolution kernel, plaque density, and luminal diameter, which have to be taken into account when performing, evaluating, and interpreting coronary CT angiography.  相似文献   

8.
To assess the image quality of coronary CT angiography (CCTA) of 640-slice CT reconstructed by Adaptive Iterative Dose Reduction (AIDR) three-dimensional (3D) in comparison with the conventional filtered back-projection (FBP). CCTA images of 51 patients were scanned at the lowest tube voltage possible on condition that the built-in automatic exposure control system could suggest the optimal tube current. They were, then, reconstructed with FBP and AIDR 3D (standard). Objective measurements including CT density, noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were performed. Subjective assessment was done by two radiologists, using a 5-point scale (0:nondiagnostic-4:excellent) based on the 15-coronary segment model which was grouped into three parts as the proximal, mid, and distal segmental classes. Radiation dose was also measured. AIDR images showed lower noise than FBP images (45.0 ± 9.4 vs. 73.4 ± 14.6 HU, p < 0.001) without any significant difference in CT density (665.5 ± 131.7 vs. 668 ± 136.3 HU, p = 0.8). Both SNR (15.0 ± 2.1 vs. 9.2 ± 1.7) and CNR (16.8 ± 2.3 vs. 10.4 ± 1.8) were significantly higher for AIDR than FBP (p < 0.001). Total subjective image quality score was also significantly improved in AIDR compared with FBP (3.1 ± 0.6 vs. 1.6 ± 0.4, p < 0.001), with better interpretability of the mid and distal segmental classes (100 vs. 95 % for the mid, p < 0.001; 100 vs. 90 % for the distal, p < 0.001). Mean effective radiation dose was 2.0 ± 1.0 mSv. The AIDR 3D reconstruction algorithm reduced image noise by 39 % compared with the FBP without affecting CT density, thus improving SNR and CNR for CCTA. Its advantages in interpretability were also confirmed by subjective evaluation by experts.  相似文献   

9.

Purpose

Clear cell tubulopapillary renal cell carcinoma (CCTPRCC) is a recently described, low-grade subtype of renal cancer. We determined if imaging features could be used to distinguish early-stage CCTPRCC from stage-matched clear cell RCC (ccRCC) and papillary RCC (pRCC).

Methods

This IRB-approved retrospective study included 54 stage T1a patients with pathologically confirmed CCTPRCC (n = 18), ccRCC (n = 18), and pRCC (n = 18). CT (n = 48) and MRI (n = 27) exams were reviewed and imaging features compared. Continuous variables were evaluated using ANOVA and Tukey’s multiple comparison tests. Categorical variables were compared using Chi-square test or Fisher’s exact test.

Results

Compared to pRCC, CCTPRCC had a lower mean attenuation value on unenhanced CT (p < 0.017), was more often hyperintense on T2-weighted images (p < 0.0001), showed an ill-defined margin (p = 0.003), and demonstrated nonenhancing areas (p = 0.0003). The presence of all three of these statistically significant features [hypoattenuation (unenhanced attenuation ≤25 HU), ill-defined margin, nonenhancing areas] yielded an area under the receiver operator curve (ROC) of 0.92 (95% CI 0.83–0.99) for differentiating CCTPRCC from pRCC. There were no significant differences in the imaging features of CCTPRCC and ccRCC.

Conclusions

Early-stage clear cell tubulopapillary renal cell carcinoma can be distinguished from papillary RCC based on low attenuation on unenhanced CT, high intensity on T2-weighted images, an ill-defined margin, and presence of nonenhancing areas, but cannot be distinguished from clear cell RCC.
  相似文献   

10.

Purpose

Early noninvasive ventilation (NIV) after extubation decreases the risk of respiratory failure and lowers 90-day mortality in patients with hypercapnia. Patients with chronic respiratory disease are at risk of extubation failure. Therefore, it could be useful to determine the role of NIV with a discontinuous approach, not limited to patients with hypercapnia. We assessed the efficacy of early NIV in decreasing respiratory failure after extubation in patients with chronic respiratory disorders.

Methods

A prospective randomized controlled multicenter study was conducted. We enrolled 144 mechanically ventilated patients with chronic respiratory disorders who tolerated a spontaneous breathing trial. Patients were randomly allocated after extubation to receive either NIV (NIV group, n = 72), performed with a discontinuous approach, for the first 48 h, or conventional oxygen treatment (usual care group, n = 72). The primary endpoint was decreased respiratory failure within 48 h after extubation. Analysis was by intention to treat. This trial was registered with ClinicalTrials.gov (NCT01047852).

Results

Respiratory failure after extubation was less frequent in the NIV group: 6 (8.5%) versus 20 (27.8%); p = 0.0016. Six patients (8.5%) in the NIV group versus 13 (18.1%) in the usual care group were reintubated; p = 0.09. Intensive care unit (ICU) mortality and 90-day mortality did not differ significantly between the two groups (p = 0.28 and p = 0.33, respectively). Median postrandomization ICU length of stay was lower in the usual care group: 3 days (IQR 2–6) versus 4 days (IQR 2–7; p = 0.008). Patients with hypercapnia during a spontaneous breathing trial were at risk of developing postextubation respiratory failure [adjusted odds ratio (95% CI) = 4.56 (1.59–14.00); p = 0.006] and being intubated [adjusted odds ratio (95% CI) = 3.60 (1.07–13.31); p = 0.04].

Conclusions

Early NIV performed following a sequential protocol for the first 48 h after extubation decreased the risk of respiratory failure in patients with chronic respiratory disorders. Reintubation and mortality did not differ between NIV and conventional oxygen therapy.
  相似文献   

11.

Purpose

Patients with acute respiratory distress syndrome (ARDS) requiring extracorporeal membrane oxygenation (ECMO) usually present very low respiratory system compliance (Cstrs) values (i.e., severe restrictive respiratory syndrome patients). As a consequence, they are at high risk of experiencing poor patient–ventilator interaction during assisted breathing. We hypothesized that monitoring of diaphragm electrical activity (EAdi) may enhance asynchrony assessment and that neurally adjusted ventilatory assist (NAVA) may reduce asynchrony, especially in more severely restricted patients.

Methods

We enrolled ten consecutive ARDS patients with very low Cstrs values undergoing ECMO after switching from controlled to pressure support ventilation (PSV). We randomly tested (30 min) while recording EAdi: (1) PSV30 (PSV with an expiratory trigger at 30 % of flow peak value); (2) PSV1 (PSV with expiratory trigger at 1 %); (3) NAVA. During each step, we measured the EAdi-based asynchrony index (AIEAdi) = flow-, pressure- and EAdi-based asynchrony events/EAdi-based respiratory rate × 100.

Results

AIEAdi was high during all ventilation modes, and the most represented asynchrony pattern was specific for this population (i.e., premature cycling). NAVA was associated with significantly decreased, although suboptimal, AIEAdi values in comparison to PSV30 and PSV1 (p < 0.01 for both). The PSV30–NAVA and PSV1–NAVA differences in AIEAdi values were inversely correlated with patients’ Cstrs (R 2 = 0.545, p = 0.01 and R 2 = 0.425, p < 0.05; respectively).

Conclusions

EAdi allows accurate analysis of asynchrony patterns and magnitude in ARDS patients with very low Cstrs undergoing ECMO. In these patients, NAVA is associated with reduced asynchrony.  相似文献   

12.
To assess the image quality and radiation dose reduction in various heart rates in coronary CT angiography using the second-generation 320-detector row CT compared with the first-generation CT. Ninety-six patients were retrospectively included. The first 48 patients underwent coronary CT angiography with the first-generation 320-detector row CT, while the last 48 patients underwent with the second-generation CT. Subjective image quality was graded using a 4-point scale (4, excellent; 1, unable to evaluate). Image noise and contrast-to-noise ratio were also analyzed. Subgroup analysis was performed based on the heart rate. The mean effective dose was derived from the dose length product multiplied by a conversion coefficient for the chest (κ = 0.014 mSv × mGy?1 × cm?1). The overall subjective image quality score showed no significant difference (3.66 vs 3.69, respectively, p = 0.25). The image quality score of the second-generation group tended to be higher than that of the first-generation group in the 66- to 75-bpm subgroup (3.36 vs 3.53, respectively, p = 0.07). No significant difference was observed in image noise and contrast-to-noise ratio. The overall radiation dose reduced by 24 % (3.3 vs 2.5 mSv, respectively, p = 0.03), and the reduction was substantial in patients with higher heart rate (66- to 75-bpm, 4.3 vs 2.2 mSv, respectively, p = 0.009; >75 bpm, 8.2 vs 3.7 mSv, respectively, p = 0.005). The second-generation 320-detector row CT could maintain the image quality while reducing the radiation dose in coronary CT angiography. The dose reduction was larger in patients with higher heart rate.  相似文献   

13.

Purpose

Nipple retraction is difficult to diagnose radiologically and extremely worrisome for patients. It occurs most commonly due to pathologies such as previous mastitis or an infiltrative malignancy. With this in mind, the goal of this study was to differentiate benign from malignant lesions of nipple retraction, using the differential characteristics of retroareolar area stiffness, observed by means of the new technological modality of ultrasound elastography (USE).

Materials and methods

Nineteen unilateral nipple retraction cases, including five cases of mammary ductal carcinoma posteriorly infiltrated the areola, two cases of Paget disease, and 12 cases of mastitis, were investigated. Imaging findings [gray-scale ultrasound (US) and USE analyses of the breasts’ nipple–areolar complex], pathological evaluation, and the results of 4 years of follow-up treatment were obtained. The recorded images were evaluated by two different radiologists, and all data were analyzed statistically.

Results

Statistical analysis showed that there was a strong correlation between the two radiologists’ evaluations. The US images were not diagnostic for either the malignant or benign conditions. The correlation between the diagnosis using US and the final diagnosis was calculated as 0.436 (p = 0.006). However, the USE images were more informative since the correlation ratio between the USE results and the final diagnosis was found to be 0.723 (p < 0.001). While the area under the concentration curve (AUC) values that were used for the diagnostic determination of the US results were inconclusive at 0.274 (p < 0.021), the AUC values for USE were significant, with a diagnostic value of 0.866 for all cases (p < 0.01).

Conclusion

The USE modality, which is not commonly used in routine practice, has the potential to solve the problem of differentiation of nipple retraction etiologies in the near future.  相似文献   

14.
Cigarette smoking is often associated with the development of several respiratory diseases however, if diagnosed early, the changes in the lung tissue caused by smoking may be reversible. Computerised respiratory sounds have shown to be sensitive to detect changes within the lung tissue before any other measure, however it is unknown if it is able to detect changes in the lungs of healthy smokers. This study investigated the differences between computerised respiratory sounds of healthy smokers and non-smokers. Healthy smokers and non-smokers were recruited from a university campus. Respiratory sounds were recorded simultaneously at 6 chest locations (right and left anterior, lateral and posterior) using air-coupled electret microphones. Airflow (1.0–1.5 l/s) was recorded with a pneumotachograph. Breathing phases were detected using airflow signals and respiratory sounds with validated algorithms. Forty-four participants were enrolled: 18 smokers (mean age 26.2, SD = 7 years; mean FEV1 % predicted 104.7, SD = 9) and 26 non-smokers (mean age 25.9, SD = 3.7 years; mean FEV1 % predicted 96.8, SD = 20.2). Smokers presented significantly higher frequency at maximum sound intensity during inspiration [(M = 117, SD = 16.2 Hz vs. M = 106.4, SD = 21.6 Hz; t(43) = ?2.62, p = 0.0081, d z  = 0.55)], lower expiratory sound intensities (maximum intensity: [(M = 48.2, SD = 3.8 dB vs. M = 50.9, SD = 3.2 dB; t(43) = 2.68, p = 0.001, d z  = ?0.78)]; mean intensity: [(M = 31.2, SD = 3.6 dB vs. M = 33.7,SD = 3 dB; t(43) = 2.42, p = 0.001, d z  = 0.75)] and higher number of inspiratory crackles (median [interquartile range] 2.2 [1.7–3.7] vs. 1.5 [1.2–2.2], p = 0.081, U = 110, r = ?0.41) than non-smokers. Significant differences between computerised respiratory sounds of smokers and non-smokers have been found. Changes in respiratory sounds are often the earliest sign of disease. Thus, computerised respiratory sounds might be a promising measure to early detect smoking related respiratory diseases.  相似文献   

15.
Calculation of fractional flow reserve (FFR) based on computational fluid dynamics (CFD) requires reconstruction of patient-specific coronary geometry and estimation of hyperemic flow rate. Coronary computed tomography angiography (CCTA) and invasive coronary angiography (ICA) are two dominating imaging modalities used for the geometrical reconstruction. Our aim was to investigate the impact of image resolution as inherently associated with these two imaging modalities on geometrical reconstruction and subsequent FFR calculation. Patients with mild or intermediate coronary stenoses who underwent both CCTA and ICA were included. CCTA images were acquired either by 320-row area detector CT or by 128-slice dual-source CT. Two geometrical models were reconstructed separately from CCTA and ICA, from which FFRCTA and FFRQCA were subsequently calculated using CFD simulations, applying the same hyperemic flow rate derived from the ICA images at the inlet boundaries. A total of 57 vessels in 41 patients were analyzed. Average diameter stenosis was 43.4 ± 10.8 % by 3D QCA. Reasonably good correlation between FFRCTA and FFRQCA was observed (r = 0.71, p < 0.001). The difference between FFRCTA and FFRQCA was correlated with the deviation between minimal lumen areas by CCTA and by ICA (ρ = 0.34, p = 0.01), but not with plaque volume (ρ = ?0.09, p = 0.51) or calcified plaque volume (ρ = 0.01, p = 0.95). Applying the cutoff value of ≤0.8 to both FFRCTA and FFRQCA, the agreement between FFRCTA and FFRQCA in discriminating functional significant stenoses was moderate (kappa 0.47, p < 0.001). Disagreement was found in 10 (17.5 %) vessels. Acceptable correlation between FFRCTA and FFRQCA was observed, while their agreement in distinguishing functional significant stenosis was moderate. Our results suggest that image resolution has a significant impact on FFR computation.  相似文献   

16.

Purpose

Previously, some reports mentioned that magnetic resonance imaging (MRI) can predict histopathological features in primary CNS lymphoma (PCNSL). The reported data analyzed diffusion-weighted imaging findings. The aim of this study was to investigate possible associations between histopathological findings, such as tumor cellularity, nucleic areas and proliferation index Ki-67, and signal intensity on T1-weighted and T2-weighted images in PCNSL.

Procedures

For this study, 18 patients with PCNSL were retrospectively investigated by histogram analysis on precontrast and postcontrast T1-weighted and fluid-attenuated inversion recovery (FLAIR) images. For every patient, histopathology parameters, nucleic count, total nucleic area, and average nucleic area, as well as Ki-67 index, were estimated.

Results

Correlation analysis identified several statistically significant associations. Skewness derived from precontrast T1-weighted images correlated with Ki-67 index (p = ? 0.55, P = 0.028). Furthermore, entropy derived from precontrast T1-weighted images correlated with average nucleic area (p = 0.53, P = 0.04). Several parameters from postcontrast T1-weighted images correlated with nucleic count: maximum signal intensity (p = 0.59, P = 0.017), P75 (p = 0.56, P = 0.02), and P90 (p = 0.52, P = 0.04) as well as SD (p = 0.58, P = 0.02). Maximum signal intensity derived from FLAIR sequence correlated with nucleic count (p = 0.50, P = 0.03).

Conclusion

Histogram-derived parameters of conventional MRI sequences can reflect different histopathological features in PSNCL.
  相似文献   

17.

Purpose

To investigate the association between 18fluorine-2-deoxy-d-glucose positron emission tomography–computed tomography (18F-FDG PET/CT) parameters, serum carcinoembryonic antigen (CEA), and tumor response in patients with rectal cancer receiving neoadjuvant chemoradiotherapy (nCRT).

Methods

Sixty-four patients with T3-4 and/or node-positive rectal cancer receiving nCRT followed by surgery were prospectively studied. PET/CT was performed before, and in 28 patients, both before and after nCRT. The pre-/post-nCRT maximum standardized uptake (SUVmax) values, differences between pre-/post-nCRT SUVmax (?SUVmax), response index of SUVmax (RI-SUVmax), mean standardized uptake value (SUVmean), metabolic tumor volume (MTV), total lesion glycolysis (TLG), and CEA were measured. The ability of PET/CT parameters and CEA to predict Mandard’s tumor regression grade (TRG) and pathological complete remission (pCR) were evaluated.

Results

31 patients were identified as responders (TRG 1–2), and 19 exhibited pCR. For responders, significant differences were found for ΔSUVmax (24.88 vs. 15.39 g/ml, p = 0.037), RI-SUVmax (0.76 vs. 0.63, p = 0.025), ΔSUVmean (14.43 vs. 8.65 g/ml, p = 0.029), RI-SUVmean (0.77 vs. 0.63, p = 0.011), CEA-pre (6.30 vs. 27.86 μg/L, p < 0.001), CEA-post (2.22 vs. 5.49 μg/L, p = 0.002), ΔCEA (4.08 vs. 23.13 μg/L, p < 0.001), and RI-CEA (0.25 vs. 0.55, p = 0.002). Differences between pCR and non-pCR patients were noted as RI-SUVmean (0.77 vs. 0.65, p = 0.043), MTV-pre (9.87 vs. 14.62 cm3, p = 0.045), CEA-pre (5.62 vs. 22.27 μg/L, p = 0.002), CEA-post (1.95 vs. 4.72 μg/L, p = 0.001), and ΔCEA (3.68 vs. 17.99 μg/L, p = 0.013). Receiver operating characteristic analysis revealed that RI-SUVmean exhibited the greatest accuracy in predicting responders, whereas CEA-post and ΔCEA exhibited the greatest accuracy in predicting pCR.

Conclusions

18F-FDG PET/CT parameters and CEA are accurate tools for predicting tumor response to nCRT in rectal cancer.
  相似文献   

18.
To individually optimize contrast medium protocol for high-pitch prospective ECG-triggering coronary CT angiography using body weight. Ninety patients undergoing high-pitch coronary CT angiography were randomly assigned to 3 contrast medium injection protocols with bolus tracking technique: Group A, 0.7 ml CM per kg patient weight (ml/kg); Group B, 0.6 ml/kg; Group C, 0.5 ml/kg. Each group had 30 patients. The CT values of superior vena cava (SVC), pulmonary artery (PA), ascending aorta (AA), left atrium (LA), left ventricle (LV), left main artery (LM) and proximal segment of right coronary artery (RCA) were measured. The image quality of coronary artery was evaluated on per-segment basis using a 4-point scale (1-excellent, 4-non-diagnosis). The CT value was not significantly different on AA (p = 0.735), LM (p = 0.764), and proximal segment of RCA (p = 0.991). The CT value was significantly different on SVC, PA, LA and LV (all p < 0.05). The mean image quality score was 1.6 ± 0.1, 1.6 ± 0.1 and 1.6 ± 0.1 (p = 0.217). The volume of CM was 47 ± 8, 44 ± 8 and 36 ± 6 ml for 3 groups (p < 0.001). The effective radiation dose was 0.88 ± 0.04, 0.87 ± 0.06, and 0.85 ± 0.07 mSv for 3 groups. Contrast medium could be reduced to 0.5 ml/kg for high-pitch coronary CT angiography without compromising diagnostic image quality, which associated ~50 % reduction of total contrast volume compared with standard contrast protocol with test bolus technique.  相似文献   

19.
Objectives This paper presents a method to register a pre-operative computed-tomography (CT) volume to a sparse set of intra-operative ultra-sound (US) slices. In the context of percutaneous renal puncture, the aim is to transfer planning information to an intra-operative coordinate system. Materials and methods The spatial position of the US slices is measured by optically localizing a calibrated probe. Assuming the reproducibility of kidney motion during breathing, and no deformation of the organ, the method consists in optimizing a rigid 6 degree of freedom transform by evaluating at each step the similarity between the set of US images and the CT volume. The correlation between CT and US images being naturally rather poor, the images were preprocessed in order to increase their similarity. Among the similarity measures formerly studied in the context of medical image registration, correlation ratio turned out to be one of the most accurate and appropriate, particularly with the chosen non-derivative minimization scheme, namely Powell-Brent’s. The resulting matching transforms are compared to a standard rigid surface registration involving segmentation, regarding both accuracy and repeatability. Results The obtained results are presented and discussed.  相似文献   

20.
A population of 165 women with negative mammographic screens also received an ultrasound tomography (UST) examination at the Karmanos Cancer Institute in Detroit, MI. Standard statistical techniques were employed to measure the associations between the various mammographic- and UST-related density measures and various participant characteristics such as age, weight and height. The mammographic percent density (MPD) was found to have similar strength associations with UST mean sound speed (Spearman coefficient, rs = 0.722, p < 0.001) and UST median sound speed (rs = 0.737, p < 0.001). Both were stronger than the associations between MPD with two separate measures of UST percent density, a k-means (rs = 0.568, p < 0.001) or a threshold (rs = 0.715, p < 0.001) measure. Segmentation of the UST sound speed images into dense and non-dense volumes showed weak to moderate associations with the mammographically equivalent measures. Relationships were found to be inversely and weakly associated between age and the UST mean sound speed (rs = ?0.239, p = 0.002), UST median sound speed (rs = ?0.226, p = 0.004) and MPD (rs = ?0.204, p = 0.008). Relationships were found to be inversely and moderately associated between body mass index (BMI) and the UST mean sound speed (rs = ?0.429, p < 0.001), UST median sound speed (rs = ?0.447, p < 0.001) and MPD (rs = ?0.489, p < 0.001). The results confirm and strengthen findings presented in previous work indicating that UST sound speed imaging yields viable markers of breast density in a manner consistent with mammography, the current clinical standard. These results lay the groundwork for further studies to assess the role of sound speed imaging in risk prediction.  相似文献   