1.

Purpose

The tumour molecular profile predicts the activity of epidermal growth factor receptor (EGFR) inhibitors in non-small-cell lung cancer (NSCLC). However, tissue availability and tumour heterogeneity limit its assessment. We evaluated whether [18F]FDG PET might help predict KRAS and EFGR mutation status in NSCLC.

Methods

Between January 2005 and October 2011, 340 NSCLC patients were tested for KRAS and EGFR mutation status. We identified patients with stage III and IV disease who had undergone [18F]FDG PET/CT scanning for initial staging. SUVpeak, SUVmax and SUVmean of the single hottest tumour lesions were calculated, and their association with KRAS and EGFR mutation status was assessed. A receiver operator characteristic (ROC) curve analysis and a multivariate analysis (including SUVmean, gender, age and AJCC stage) were performed to identify the potential value of [18F]FDG PET/CT for predicting KRAS mutation.

Results

From 102 patients staged using [18F]FDG PET/CT, 28 (27 %) had KRAS mutation (KRAS+), 22 (22 %) had EGFR mutation (EGFR+) and 52 (51 %) had wild-type KRAS and EGFR profiles (WT). KRAS+ patients showed significantly higher [18F]FDG uptake than EGFR+ and WT patients (SUVmean 9.5, 5.7 and 6.6, respectively; p?18F]FDG uptake between EGFR+ patients and WT patients. ROC curve analysis for KRAS mutation status discrimination yielded an area under the curve of 0.740 for SUVmean (p?Conclusion NSCLC patients with tumours harbouring KRAS mutations showed significantly higher [18F]FDG uptake than WT patients, as assessed in terms of SUVpeak, SUVmax and SUVmean. A multivariate model based on age, gender, AJCC stage and SUVmean might be used as a predictive marker of KRAS mutation status in patients with stage III or IV NSCLC.  相似文献   

2.

Objective

IQ-SPECT (Siemens AG, Munich, Germany) is a highly sensitive single-photon-emission computed tomography (SPECT) myocardial perfusion imaging (MPI) system that uses a multifocal collimator. We searched for a suitable protocol for short-time imaging by IQ-SPECT in thallium-201 (Tl-201) MPI by evaluating phantom images and also by comparing human IQ-SPECT images with conventional SPECT images as reference standards.

Methods

We assessed the image quality using the normalized mean square error (NMSE) and drew up count profiles in Tl-201 SPECT images acquired with IQ-SPECT in a phantom study. We also performed Tl-201 stress myocardial SPECT/CT in 21 patients and compared delayed images acquired by using IQ-SPECT with 36 or 17 views per head with images obtained by using conventional SPECT.

Results

The NMSE of SPECT images from IQ-SPECT with 36 views was approximately one-fifth of that with 17 views. The myocardial count profile of images with 17 views was lower than those of images with 36 or 104 views in some regions. Defect scores were significantly lower, and image quality scores higher, in images from conventional SPECT than in those from IQ-SPECT with 17 views. Defect scores and image quality scores were equivalent in images from conventional SPECT and those from IQ-SPECT with 36 views. Agreement with the results of conventional SPECT in terms of coronary artery territory-based defect judgment was the best in IQ-SPECT with 36 views with computed tomography-derived attenuation correction (CTAC): the kappa values for IQ-SPECT with 36 views were 0.76 (without CTAC) and 0.83 (with CTAC), and those for IQ-SPECT with 17 views were 0.62 (without CTAC) and 0.59 (with CTAC). The difference in quantitative tracer uptake between conventional SPECT images and IQ-SPECT images was significantly greater for IQ-SPECT images with 17 views than for those with 36 views.

Conclusions

Scanning with 36 views per head with CTAC may be appropriate for Tl-201 MPI using IQ-SPECT, because it provides images equivalent to those using conventional SPECT.  相似文献   

3.

Purpose

Adrenocortical carcinoma (ACC) is a rare and aggressive malignancy. Limited data are available about on value of 18F-FDG PET/CT in ACC. We evaluated the impact of PET/CT on the management of ACC.

Methods

We performed a retrospective review in patients with ACC who had undergone PET/CT. The impact of PET/CT on the management plan was evaluated by comparing the findings on PET/CT to the findings on contrast-enhanced CT. The sensitivity, specificity, and accuracy of each form of imaging were calculated. The correlations between PET/CT parameters, including maximum standardized uptake value (SUVmax), total lesion glycolysis, and decline in SUVmax after chemotherapy, and clinical outcome were evaluated.

Results

Included in the analysis were 106 patients with 180 PET/CT scans. Of the 106 patients, 7 underwent PET/CT only for initial staging, 84 underwent PET/CT only for restaging, and 15 underwent PET/CT for both initial staging and restaging. PET/CT changed the management plan in 1 of 22 patients (5 %) at initial staging and 9 of 99 patients (9 %) at restaging. In 5 of the patients in whom PET/CT changed the management plan, PET/CT showed response to chemotherapy but contrast-enhanced CT showed stable disease. Sensitivity, specificity, and accuracy were 100 %, 100 %, and 100 % for PET/CT at initial staging; 92.6 %, 100 %, and 96.4 % for CT at initial staging; 98.4 %, 100 %, and 99.5 % for PET/CT at restaging; and 96.8 %, 98.6 %, and 98.0 % for CT at restaging, respectively. No PET/CT parameters were associated with survival at either initial diagnosis or recurrence.

Conclusion

PET/CT findings could substantially change the management plan in a small proportion of patients with ACC. Although lesion detection was similar between PET/CT and CT, PET/CT may be preferred for chemotherapeutic response assessment because it may predict response before anatomic changes are detected on CT.  相似文献   

4.
Published data on the diagnosis of bone metastases of prostate cancer are conflicting and heterogeneous. We performed a comprehensive meta-analysis to compare the diagnostic performance of choline-PET/CT, MRI, bone SPECT, and bone scintigraphy (BS) in detecting bone metastases in parents with prostate cancer. Pooled sensitivity, specificity, and diagnostic odds ratios (DOR) were calculated both on a per-patient basis and on a per-lesion basis. Summary receiver operating characteristic (SROC) curves were also drawn to obtain the area under curve (AUC) and Q* value. Sixteen articles consisting of 27 studies were included in the analysis. On a per-patient basis, the pooled sensitivities by using choline PET/CT, MRI, and BS were 0.91 [95 % confidence interval (CI): 0.83–0.96], 0.97 (95 % CI: 0.91–0.99), 0.79 (95 % CI: 0.73–0.83), respectively. The pooled specificities for detection of bone metastases using choline PET/CT, MRI, and BS, were 0.99 (95 % CI: 0.93–1.00), 0.95 (95 % CI: 0.90–0.97), and 0.82 (95 % CI: 0.78–0.85), respectively. On a per-lesion basis, the pooled sensitivities of choline PET/CT, bone SPECT, and BS were 0.84 (95 % CI: 0.81–0.87), 0.90 (95 % CI: 0.86–0.93), 0.59 (95 % CI: 0.55–0.63), respectively. The pooled specificities were 0.93 (95 % CI: 0.89–0.96) for choline PET/CT, 0.85 (95 % CI: 0.80–0.90) for bone SPECT, and 0.75 (95 % CI: 0.71–0.79) for BS. This meta-analysis indicated that MRI was better than choline PET/CT and BS on a per-patient basis. On a per-lesion analysis, choline PET/CT with the highest DOR and Q* was better than bone SPECT and BS for detecting bone metastases from prostate cancer.  相似文献   

5.

Objectives

To assess the value of secretin during magnetic resonance cholangiopancreatography (MRCP) in demonstrating communication between cystic lesions and the pancreatic duct to help determine the diagnosis of side-branch intraductal papillary mucinous neoplasm (SB-IPMN).

Methods

This is an IRB-approved, HIPAA-compliant retrospective study of 29 SB-IPMN patients and 13 non-IPMN subjects (control) who underwent secretin-enhanced MRCP (s-MRCP). Two readers blinded to the final diagnosis reviewed three randomised image sets: (1) pre-secretin HASTE, (2) dynamic s-MRCP and (3) post-secretin HASTE. Logistic regression, generalised linear models and ROC analyses were used to compare pre- and post-secretin results.

Results

There was no significant difference in median scores for the pre-secretin [reader 1: 1; reader 2: 2 (range -2 to 2)] and post-secretin HASTE [reader 1: 1; reader 2: 1 (range -2 to 2)] in the SB-IPMN group (P?=?0.14), while the scores were lower for s-MRCP [reader 1: 0.5 (range -2 to 2); reader 2: 0 (range -1 to 2); P?=?0.016]. There was no significant difference in mean maximum diameter of SB-IPMN on pre- and post-secretin HASTE, and s-MRCP (P?>?0.05).

Conclusion

Secretin stimulation did not add to MRCP in characterising pancreatic cystic lesions as SB-IPMN.

Key Points

? Magnetic resonance cholangiopancreatography (MRCP) is used to evaluate pancreatic cystic lesions. ? Intraductal papillary mucinous neoplasm (IPMN) is a type of pancreatic cystic neoplasm. ? Secretin administration does not facilitate the diagnosis of IPMN on MRCP.  相似文献   

6.

Introduction

We assessed the validity of “perfusion-metabolism coupling” hypothesis in recurrent glioma with 13N-ammonia (13N-NH3) PET/CT and 18F-fluorodeoxyglucose (18F-FDG) PET/CT.

Methods

Fifty-six consecutive patients (age, 38.8?±?12.1 years; 62.5 % males) with histologically proven and previously treated glioma presenting with clinical suspicion of recurrence were prospectively enrolled and evaluated with 13N-NH3 PET/CT and 18F-FDG PET/CT. PET/CT images were evaluated both qualitatively and semiquantitatively. Tumor to white matter uptake ratio (T/W) and tumor to gray matter uptake ratio (T/G) were calculated and analyzed for both the modalities. A combination of clinico-radiological follow-up, repeated imaging, and biopsy (when available) were considered as the reference standard.

Results

Based on the reference standard, 27/56 patients had recurrence. 13N-NH3 PET/CT and 18F-FDG PET/CT were concordant in 55/56 patients. Overall sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of 13N-NH3PET/CT were 77.8, 86.2, 84.0, 80.7, and 82.1 %, respectively, and for 18F-FDG PET/CT were 77.8, 89.7, 87.5, 81.2, and 83.9 %, respectively. There was excellent agreement between results of 13N-NH3 PET/CT and 18F-FDG PET/CT (??=?0.964; P?13N-NH3 PET/CT and 18F-FDG PET/CT were not significantly different between high-grade and low-grade glioma (P?=?1.000). A strong positive correlation was noted between the uptake ratios derived on the two modalities (ρ?=?0.866, P?ρ?=?0.918, P?Conclusion A combination of 13N-NH3 PET/CT and 18F-FDG PET/CT demonstrates that perfusion and metabolism are coupled in recurrent gliomas. These tracers target two different but interrelated aspects of the same pathologic process and can be used as surrogates for each other.  相似文献   

7.
8.

Objective

Our objective was to evaluate ultrafast cone-beam computed tomography (u-CBCT) image data using cross-sectional images, perfusion blood volume (PBV), and image fusion during tumour detection at the course of transarterial chemoembolization.

Methods

One hundred and fifty patients (63?±?20 years; 33–82) were examined from February to October 2013 with u-CBCT. Tumour delineation and conspicuity were determined using u-CBCT cross-sectional PBV and u-CBCT-magnetic resonance imaging (MRI) fused data sets for hyperenhanced (HYET), heterogeneously enhanced (HEET), and unenhanced (UET) tumour categories. Catheter localisation and tumour feeding vessels were assessed using all data sets. Quantitative and qualitative analyses were performed using appropriate statistical tests.

Result

Qualitative and quantitative tumour delineation showed significant difference (all P?P?P?Conclusion Tumour delineation was clearly possible using u-CBCT cross sections with contrast material. PBV uses color-coded images to increase detection and produces good tumour differentiation. Image fusion helps accurately identify tumour and feeding vessels and locate contrast material injection sites and catheter tips without additional data acquisition.

Key points

? Ultrafast CBCT cross-sectional data provide good tumour delineation with contrast material ? Postprocessed PBV using u-CBCT increased detectability and tumour differentiation ? u-CBCT cross-sectional PBV and u-CBCT-MRI data helps image guidance during chemoembolization ? u-CBCT-MRI can identify tumours and feeding vessels and locate catheter tip accurately  相似文献   

9.

Purpose

Nodular lymphocyte-predominant Hodgkin lymphoma (NLPHL) is a rare Hodgkin lymphoma distinguished from classical Hodgkin lymphoma (cHL) by the nature of the neoplastic cells which express B-cell markers. We wanted to determine the diagnostic performance of FDG PET/CT in initial assessment and its therapeutic impact on staging.

Methods

We retrospectively studied a population of 35 patients with NLPHL (8 previously treated for NLHPL, 27 untreated). All patients underwent an initial staging by pretherapeutic FDG PET/CT. The impact on initial stage or relapse stage was assessed by an independent physician.

Results

In a per-patient analysis, the sensitivity of the pretherapeutic FDG PET/CT was 100 %. In a per-site analysis, the sensitivity, specificity, positive predictive value, negative predictive value and accuracy of pretherapeutic FDG PET/CT were 100 %, 99 %, 97 %, 100 % and 99 %, respectively. Pretherapeutic FDG PET/CT led to a change in the initial stage/relapse stage in 12 of the 35 patients (34 %). In contrast to previous results established without FDG PET/CT, 20 % of patient had osteomedullary lesions.

Conclusion

Pretherapeutic FDG PET/CT has excellent performance for initial staging or relapse staging of NLPHL.  相似文献   

10.

Objective

Our aim was to test the feasibility of blood oxygen level dependent magnetic resonance imaging (BOLD MRI) and dynamic contrast-enhanced (DCE) MRI to monitor periarticular hypoxic/inflammatory changes over time in a juvenile rabbit model of arthritis.

Methods

We examined arthritic and contralateral nonarthritic knees of 21 juvenile rabbits at baseline and days 1,14, and 28 after induction of arthritis by unilateral intra-articular injection of carrageenin with BOLD and DCE MRI at 1.5 Tesla (T). Nine noninjected rabbits served as controls. Associations between BOLD and DCE-MRI and corresponding intra-articular oxygen pressure (PO2) and blood flow [blood perfusion units (BPU)] (polarographic probes, reference standards) or clinical–histological data were measured by correlation coefficients.

Results

Percentage BOLD MRI change obtained in contralateral knees correlated moderately with BPU on day 0 (r?=??0.51, p?=?0.02) and excellently on day 28 (r?=??0.84, p?=?0.03). A moderate correlation was observed between peak enhancement DCE MRI (day 1) and BPU measurements in arthritic knees (r?=?0.49, p?=?0.04). In acute arthritis, BOLD and DCE MRI highly correlated (r?=?0.89, p?=?0.04; r?=?1.0, p?Conclusion The proposed techniques are feasible to perform at 1.5 T, and they hold potential as surrogate measures to monitor hypoxic and inflammatory changes over time in arthritis at higher-strength MRI fields.

Key points

? BOLD and DCE MRI detect interval perisynovial changes in a rabbit knee ? BOLD and DCE MRI act as surrogate markers of physiologic changes in arthritis ? BOLD MRI signal represents oxygen extraction compared with intra-articular PO 2 ? DCE MRI measurements estimate physiologic periarticular vascular properties ? In rabbit knees with acute arthritis, BOLD/DCE MRI highly correlated with histological scores  相似文献   

11.

Purpose

This study compares the quality of intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) plans optimized for an Elekta AgilityTM (Elekta, Stockholm, Sweden) multileaf collimator (MLC; leaf width 5 mm) and an Elekta MLCi2 (leaf width 10 mm) for complex target volumes (anal, AC; head and neck, H&N and prostate cancer, PC).

Patients and methods

For plan comparisons, 15 patients who had been treated with IMRT or VMAT using the MLCi2 were selected. For each patient, a retrospective treatment plan using the MLCi2 for the technique not applied was created, as were treatment plans for both techniques using the AgilityTM MLC. Dose–volume histograms (DHVs) for planning target volumes (PTVs) and organs at risk (OARs) were compared. Further parameters relating to dose conformity, dose homogeneity and mean dose (Dmean) to the PTV, compliance with the intended OAR dose criteria and overall dose to normal tissue were analyzed. Verification measurements were performed and optimization and treatment times were compared.

Results

Compared to the MLCi2 plans, the AgilityTM IMRT and VMAT plans show better or equivalent results in terms of PTV dose conformity and homogeneity. Compliance with the intended OAR dose criteria does not differ according to technique or MLC type. Slight differences are shown for dose distributions in OARs and normal tissue. Verification measurements show that all plans fulfill the acceptance criteria of a minimum of 95 % matched dose points for the 3 %/3 mm γ criterion. Optimization times for the VMAT plans increase compared to the IMRT plans, whereas treatment times decrease.

Conclusion

With the MLCi2, treatment of complex target volumes with VMAT was only possible with compromises in terms of target coverage. Using the AgilityTM MLC, even complex target volumes can be treated with VMAT without compromising target coverage or resulting in higher exposure of OARs or normal tissue.  相似文献   

12.

Purpose

To determine the prognostic value of 68Ga-DOTANOC PET/CT in patients with well-differentiated neuroendocrine tumor (NET), and to compare the prognostic value with that of 18F-FDG PET/CT and other conventional clinicopathological prognostic factors.

Methods

Data from 37 consecutive patients (age 46.6?±?13.5 years, 51 % men) with well-differentiated NET who underwent 68Ga-DOTANOC PET/CT and 18F-FDG PET/CT were analyzed. All patients underwent a baseline visit with laboratory and radiological examinations. Clinical and imaging follow-up was performed in all patients. Progression-free survival (PFS) was measured from the date of the first PET/CT scan to the first documentation of progression of disease.

Results

68Ga-DOTANOC PET/CT was positive in 37 of the 37 patients and 18F-FDG PET/CT was positive in 21. During follow-up 10 patients (27 %) showed progression of disease and 27 (73 %) showed no progression (24 stable disease, 3 partial response). The median follow-up was 25 months (range 2 – 52 months). Among the variables evaluated none was significantly different between the progressive disease and nonprogressive disease groups, with only SUVmax on 68Ga-DOTANOC PET/CT being borderline significant (P?=?0.073). In the univariate analysis for PFS outcome, SUVmax on 68Ga-DOTANOC PET/CT (HR 0.122, 95 % CI 0.019 – 0.779; P?=?0.026) and histopathological tumor grade (HR 4.238, 95 % CI 1.058 – 16.976; P?=?0.041) were found to be associated with PFS. Other factors including age, sex, primary site, Ki-67 index, TNM stage, 18F-FDG PET/CT status (positive/negative), SUVmax on 18F-FDG PET/CT and type of treatment were not significant. In multivariable analysis, only SUVmax on 68Ga-DOTANOC PET/CT was found to be an independent positive predictor of PFS (HR 0.122, 95 % CI 0.019 – 0.779; P?=?0.026).

Conclusion

SUVmax measured on 68Ga-DOTANOC PET/CT is an independent, positive prognostic factor in patients with well-differentiated NET and is superior to SUVmax on 18F-FDG PET/CT and conventional clinicopathological factors for predicting PFS.  相似文献   

13.

Objective

This study was done to assess breast density on digital mammography and digital breast tomosynthesis according to the visual Breast Imaging Reporting and Data System (BI–RADS) classification, to compare visual assessment with Quantra software for automated density measurement, and to establish the role of the software in clinical practice.

Materials and methods

We analysed 200 digital mammograms performed in 2D and 3D modality, 100 of which positive for breast cancer and 100 negative. Radiological density was assessed with the BI–RADS classification; a Quantra density cut-off value was sought on the 2D images only to discriminate between BI–RADS categories 1–2 and BI–RADS 3–4. Breast density was correlated with age, use of hormone therapy, and increased risk of disease.

Results

The agreement between the 2D and 3D assessments of BI–RADS density was high (K 0.96). A cut-off value of 21 % is that which allows us to best discriminate between BI–RADS categories 1–2 and 3–4. Breast density was negatively correlated to age (r =  ?0.44) and positively to use of hormone therapy (p = 0.0004). Quantra density was higher in breasts with cancer than in healthy breasts.

Conclusions

There is no clear difference between the visual assessments of density on 2D and 3D images. Use of the automated system requires the adoption of a cut-off value (set at 21 %) to effectively discriminate BI–RADS 1–2 and 3–4, and could be useful in clinical practice.  相似文献   

14.

Objective

The purpose of this study was to investigate the diagnostic performance of postoperative fluorine-18 fluoro-2-deoxy-d-glucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) as a surveillance modality for advanced gastric cancer patients who were asymptomatic and negative by conventional follow-up.

Methods

We retrospectively collected 46 advanced gastric cancer patients who received approximately 1-year-postoperative 18F-FDG PET/CT surveillance following curative resection (mean age 60.6 ± 11.5 years). 18F-FDG PET/CT was interpreted by nuclear medicine physicians who were blind to the clinical information. Final confirmation was determined by clinical follow-up using tumor markers, conventional CT scan, upper gastrointestinal endoscopy and with/without subsequent histopathologic diagnosis.

Results

Four patients developed recurrence (8.7 %; 1 local and 3 distant recurrences). For local recurrence, 18F-FDG PET/CT found four hypermetabolic lesions and one was local recurrence. For distant recurrence, seven hypermetabolic lesions were found in six patients and true-positive was three lesions. False-positive cases were mainly turned out to be physiologic small bowel uptake. Regardless of the recurrence site, the sensitivity, specificity, positive predictive value and negative predictive value of 18F-FDG PET/CT were 100 % (4/4, 95 % confidence interval (CI) 39.6–100 %), 88.1 % (37/42, 95 % CI 73.6–95.5 %), 44.4 % (4/9, 95 % CI 15.3–77.3 %) and 100 % (37/37, 95 % CI 88.3–100 %), respectively in the patient-based analysis.

Conclusion

Our study showed good specificity of postoperative surveillance 18F-FDG PET/CT for detecting recurrence. Careful caution should be made for interpreting some false-positive hypermetabolic lesions in postoperative 18F-FDG PET/CT, especially at the local anastomosis site.  相似文献   

15.

Purpose

Primary hyperparathyroidism is a common endocrine disorder which is diagnosed biochemically and for which therapy is surgical. A prerequisite for minimally invasive surgery, which minimizes morbidity and cost, is accurate localization of the involved gland(s). The aim of this study was to evaluate the usefulness of 18F-fluorocholine PET/CT for preoperative localization of hyperfunctioning parathyroid tissue.

Methods

18F-Fluorocholine PET/CT and conventional parathyroid scintigraphic imaging consisting of 99mTc-sestaMIBI SPECT/CT, 99mTc-sestaMIBI dual-phase imaging and 99mTc-sestaMIBI/pertechnetate subtraction imaging were performed in 24 patients. The diagnostic performance of the imaging methods was compared against histology as the gold standard and postoperative serum Ca2+ and iPTH values.

Results

The sensitivity and specificity of 18F-fluorocholine PET/CT were 92 % and 100 %, respectively, in contrast to 49 % and 100 %, 46 % and 100 %, and 44 % and 100 % for 99mTc-sestaMIBI SPECT/CT, 99mTc-sestaMIBI/pertechnetate subtraction imaging and 99mTc-sestaMIBI dual-phase imaging, respectively. Combined conventional scintigraphic imaging had a sensitivity and specificity of 64 % and 100 %, respectively. The performance of 18F-fluorocholine PET/CT was superior particularly in patients with multiple lesions or hyperplasia.

Conclusion

18F-Fluorocholine PET/CT appears to be a promising, effective imaging method for localization of hyperfunctioning parathyroid tissue.  相似文献   

16.

Objectives

To evaluate DWI of the bone marrow in the differentiation of monoclonal gammopathy of undetermined significance (MGUS), smouldering myeloma (SMM) and multiple myeloma (MM).

Methods

The retrospective study includes 64 patients with MGUS, 27 with SMM, 64 with new MM and 12 controls. Signal intensity (SI) of spinal SE-MRI and DWI (b0-1000) as well as apparent diffusion coefficients (ADC) were measured in the T10 and L3. Qualitative assessment of b-images was performed by one experienced radiologist.

Results

ADC600 and ADC1000 are the best ADC values in differentiating patient groups (p?p?MGUS and MM (p?50 % (p?=?0.001). Only SIT2 for L3 can differentiate MGUS from SMM (p?=?0.044) and PC%0-10 from PC%10-25 (p?=?0.033). Qualitative interpretation of b1000 images allows differentiating MM patients from those with MGUS or SMM (p?Conclusions Spinal SE-MRI can differentiate among MGUS, SMM, MM and control subjects. DWI based on the SI on b1000 images and ADC values is increased in MM compared to MGUS and SMM. Qualitative assessment of b-images can differentiate MM from MGUS or SMM.

Key points

? ADC values are higher in patients with MM compared to MGUS ? DWI parameters change late in disease evolution ? DWI is sensitive but not specific in diagnosing patients with MM ? Qualitative DWI assessment is good in detecting myeloma patients  相似文献   

17.

Purpose

This report of the Working Group on Stereotactic Radiotherapy of the German Society of Radiation Oncology (DEGRO) aims to provide a practical guideline for safe and effective stereotactic body radiotherapy (SBRT) of liver tumors.

Methods

The literature on the clinical evidence of SBRT for both primary liver tumors and liver metastases was reviewed and analyzed focusing on both physical requirements and special biological characteristics.

Results

Recommendations were developed for patient selection, imaging, planning, treatment delivery, motion management, dose reporting, and follow-up. Radiation dose constraints to critical organs at risk are provided.

Conclusion

SBRT is a well-established treatment option for primary and secondary liver tumors associated with low morbidity.  相似文献   

18.

Objectives

The aim of this study was to assess the diagnostic performance of pre-treatment 3-Tesla (3T) multiparametric magnetic resonance imaging (mpMRI) for predicting Gleason score (GS) downgrading after radical prostatectomy (RP) in patients with GS 3?+?4 prostate cancer (PCa) on biopsy.

Methods

We retrospectively reviewed 304 patients with biopsy-proven GS 3?+?4 PCa who underwent mpMRI before RP. On T2-weighted imaging and three mpMRI combinations (T2-weighted imaging + diffusion-weighted imaging [DWI], T2-weighted imaging + dynamic contrast-enhanced-MRI [DCE-MRI], and T2-weighted imaging + DWI + DCE-MRI), two radiologists (R1/R2) scored the presence of a dominant tumour using a 5-point Likert scale (1 = definitely absent to 5 = definitely present). Diagnostic performance in identifying downgrading was evaluated via areas under the curves (AUCs). Predictive accuracies of multivariate models were calculated.

Results

In predicting downgrading, T2-weighted imaging + DWI (AUC?=?0.89/0.85 for R1/R2) performed significantly better than T2-weighted imaging alone (AUC?=?0.72/0.73; p?DCE-MRI (AUC?=?0.89/0.84 for R1/R2) performed no better than T2-weighted imaging + DWI (p?=?0.48/p?>?0.99 for R1/R2). On multivariate analysis, the clinical + mpMRI model incorporating T2-weighted imaging + DWI (AUC?=?0.92/0.88 for R1/R2) predicted downgrading significantly better than the clinical model (AUC?=?0.73; p?Conclusion mpMRI improves the ability to identify a subgroup of patients with Gleason 3?+?4 PCa on biopsy who are candidates for active surveillance. DCE-MRI (compared to T2 + DWI) offered no additional benefit to the prediction of downgrading.

Key Points

? Diagnostic performance of T2-weighted-imaging + DWI was better than T2-weighted-imaging alone. ? Diagnostic performance of T2-weighted-imaging + DWI was similar to T2-weighted-imaging + DWI + DCE-MRI. ? Combining clinical and T2-weighted-imaging + DWI features best predicted GS downgrading. ? mpMRI might prevent overtreatment by increasing eligibility for PCa active surveillance.  相似文献   

19.

Background

Human epidermal growth factor receptor 2 (ErbB2) is overexpressed in a variety of human malignancies. Moreover, ErbB2 has been reported to influence cancer patient survival and progression of different tumor entities. However, information regarding the prognostic impact of ErbB2 in soft tissue sarcoma (STS) patients is limited and conflicting.

Material and methods

ErbB2 mRNA and protein levels were defined by quantitative real-time PCR and enzyme-linked immunosorbent assay (ELISA), and the prognostic impact of ErbB2 mRNA and protein levels in tumor tissue of 124 soft tissue sarcoma patients were investigated.

Results

The median ErbB2 mRNA expression level in tumor tissue was decreased 3.9-fold compared to non-neoplastic surrounding tissue (p?=?0.001). Furthermore, an increased ErbB2 mRNA expression level was associated with an improved tumor-specific survival (p?=?0.01, log rank test). Multivariate Cox’s proportional hazard regression analyses revealed an increased ErbB2 mRNA expression level as an independent favorable prognostic factor for tumor-specific survival of STS patients (n?=?124; RR?=?3.0; 95?% CI?=?1.6–5.7; p?n?=?47; RR?=?9.9; 95?% CI?=?1.7–59.7; p?=?0.012), in particular for STS patients who received postoperative radiotherapy (n?=?27; RR?=?17.9; 95?% CI?=?1.3–247.7; p?=?0.031).

Conclusion

This study suggests an inverse prognostic value of ErbB2 mRNA and protein expression level.  相似文献   

20.

Purpose

This study evaluated the accuracy of MR sequences [T2-, diffusion-weighted, and dynamic contrast-enhanced (T2WI, DWI, and DCE) imaging] at 3T, based on the European Society of Urogenital Radiology (ESUR) scoring system [Prostate Imaging Reporting and Data System (PI-RADS)] using MR-guided in-bore prostate biopsies as reference standard.

Methods

In 235 consecutive patients [aged 65.7?±?7.9 years; median prostate-specific antigen (PSA) 8 ng/ml] with multiparametric prostate MRI (mp-MRI), 566 lesions were scored according to PI-RADS. Histology of all lesions was obtained by targeted MR-guided in-bore biopsy.

Results

In 200 lesions, biopsy revealed prostate cancer (PCa). The area under the curve (AUC) for cancer detection was 0.70 (T2WI), 0.80 (DWI), and 0.74 (DCE). A combination of T2WI + DWI, T2WI + DCE, and DWI + DCE achieved an AUC of 0.81, 0.78, and 0.79. A summed PI-RADS score of T2WI + DWI + DCE achieved an AUC of 0.81. For higher grade PCa (primary Gleason pattern?≥?4), the AUC was 0.85 for T2WI + DWI, 0.84 for T2WI + DCE, 0.86 for DWI + DCE, and 0.87 for T2WI + DWI + DCE. The AUC for T2WI + DWI + DCE for transitional-zone PCa was 0.73, and for the peripheral zone 0.88. Regarding higher-grade PCa, AUC for transitional-zone PCa was 0.88, and for peripheral zone 0.96.

Conclusion

The combination of T2WI + DWI + DCE achieved the highest test accuracy, especially in patients with higher-grade PCa. The use of ≤2 MR sequences led to lower AUC in higher-grade and peripheral-zone cancers.

Key Points

? T2WI + DWI + DCE achieved the highest accuracy in patients with higher grade PCa ? T2WI + DWI + DCE was more accurate for peripheral- than for transitional-zone PCa ? DCE increased PCa detection accuracy in the peripheral zone ? DWI was the leading sequence in the transitional zone  相似文献   