首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Building constructions and their elements must meet requirements related to stability and strength. These are the conditions that determine the safety of the structure during both construction and operation. Safety assessment is based on diagnostic tests, aimed at checking the quality of the erected objects or locating damage to structural elements that arise during operation. This work focuses on experimental SISO modal analysis of ceramic masonry elements. An experiment was carried out on twenty samples of solid brick (good, and intentionally damaged). From this, it was possible to determine the variability of the obtained measurement results of the vibration characteristics of the masonry element, and, thus, to assess the value of the method used in the given research problem. The aim of this study was to test the effectiveness of assessing the degradation of the tested brick elements based on stabilization diagrams. The research confirmed the usefulness of experimental modal analysis in identifying damage to masonry elements, and it has been implemented in selected brickyards in Poland.  相似文献   

2.
The evaluation of the shear behavior of masonry walls is a first fundamental step for the assessment of existing masonry structures in seismic zones. However, due to the complexity of modelling experimental behavior and the wide variety of masonry types characterizing historical structures, the definition of masonry’s mechanical behavior is still a critical issue. Since the possibility to perform in situ tests is very limited and often conflicting with the needs of preservation, the characterization of shear masonry behavior is generally based on reference values of mechanical properties provided in modern structural codes for recurrent masonry categories. In the paper, a combined test procedure for the experimental characterization of masonry mechanical parameters and the assessment of the shear behavior of masonry walls is presented together with the experimental results obtained on three stone masonry walls. The procedure consists of a combination of three different in situ tests to be performed on the investigated wall. First, a single flat jack test is executed to derive the normal compressive stress acting on the wall. Then a double flat jack test is carried out to estimate the elastic modulus. Finally, the proposed shear test is performed to derive the capacity curve and to estimate the shear modulus and the shear strength. The first results obtained in the experimental campaign carried out by the authors confirm the capability of the proposed methodology to assess the masonry mechanical parameters, reducing the uncertainty affecting the definition of capacity curves of walls and consequently the evaluation of seismic vulnerability of the investigated buildings.  相似文献   

3.
For decades, one of the most critical considerations of civil engineers has been the construction of structures that can sufficiently resist earthquakes. However, in many parts of the globe, ancient and contemporary buildings were constructed without regard for engineering; thus, there is a rising necessity to adapt existing structures to avoid accidents and preserve historical artefacts. There are various techniques for retrofitting a masonry structure, including foundation isolations, the use of Fibre-Reinforced Plastics (FRPs), shotcrete, etc. One innovative technique is the use of Shape Memory Alloys (SMAs), which improve structures by exhibiting high strength, good re-centring capabilities, self-repair, etc. One recent disastrous earthquake that happened in the city of Bam, Iran, (with a large proportion of masonry buildings) in 2003, with over 45,000 casualties, is analysed to discover the primary causes of the structural failure of buildings and its ancient citadel. It is followed by introducing the basic properties of SMAs and their applications in retrofitting masonry buildings. The outcomes of preceding implementations of SMAs in retrofitting of masonry buildings are then employed to present two comprehensive schemes as well as an implementation algorithm for strengthening masonry structures using SMA-based devices.  相似文献   

4.
In-plane strength of masonry walls is affected by the resistant mechanisms activated in the walls, i.e., related to flexural or shear behavior. The latter one can occur in the walls according to different failure modes depending on both mortar and unit strengths and on the type of assembling, i.e., ‘regular’ or ‘irregular’ texture. In this paper, a critical review of the existing design formulations for the in-plane strength of masonry walls is firstly presented, with important information on the achievable failure modes depending on the geometrical and mechanical features of the masonry fabric. Then, experimental tests are collected from the literature and a comparison between theoretical and experimental results is carried out. The presented analyses are aimed to highlight the differences between the existing formulations and to identify the most suitable ones.  相似文献   

5.
Masonry material characteristics, such as compressive strength, and the relationship between brick, mortar, and masonry compressive strengths are required for the analysis and assessment of masonry structures. This paper aimed to investigate the compressive strength relationship of Cambodian masonry. A total number of 42 prisms were constructed in the laboratory using six different brick/mortar combinations. Two brick types, solid and hollow, and three—1:3, 1:4, and 1:6—cement–sand mortar combinations were used. The effects of brick and mortar strengths were analysed. Using regression analysis, a simple empirical relationship was derived for masonry compressive strength as a function of brick and mortar strength in the Cambodian context.  相似文献   

6.
This study presents a new way to improve masonry wall behavior. Masonry structures comprise a significant part of the world’s structures. These structures are very vulnerable to earthquakes, and their performances need to be improved. One way to enhance the performances of such types of structures is the use of post-tensioning reinforcements. In the current study, the effects of shape memory alloy as post-tensioning reinforcements on originally unreinforced masonry walls were investigated using finite element simulations in Abaqus. The developed models were validated based on experimental results in the literature. Iron-based shape memory alloy strips were installed on masonry walls by three different configurations, namely in cross or vertical forms. Seven macroscopic masonry walls were modeled in Abaqus software and were subjected to cyclic loading protocol. Parameters such as stiffness, strength, durability, and energy dissipation of these models were then compared. According to the results, the Fe-based strips increased the strength, stiffness, and energy dissipation capacity. So that in the vertical-strip walls, the stiffness increases by 98.1%, and in the cross-strip model’s position, the stiffness increases by 127.9%. In the vertical-strip model, the maximum resistance is equal to 108 kN, while in the end cycle, this number is reduced by almost half and reaches 40 kN, in the cross-strip model, the maximum resistance is equal to 104 kN, and in the final cycle, this number decreases by only 13.5% and reaches 90 kN. The scattering of Fe-based strips plays an important role in energy dissipation. Based on the observed behaviors, the greater the scattering, the higher the energy dissipation. The increase was more visible in the walls with the configuration of the crossed Fe-based strips.  相似文献   

7.
Several masonry structures of cultural and historical interest are made with a non-periodic masonry material. In the case of periodic textures, several methods are available to estimate the strength of the masonry; however, in the case of non-periodic masonry, few methods are available, and they are frequently difficult to use. In the present paper we propose using discontinuity layout optimization (DLO) to estimate the failure load and mechanism of a masonry wall made with non-periodic texture. We developed a parametric analysis to account for the main features involved in the estimation of failure: in particular we considered three different textures (periodic, quasi-periodic, and chaotic), variable height-to-width ratio of the wall (from 0 to 3) and of the blocks (from 0.25 to 1), different mechanical properties of mortar joints and blocks, and possible presence of a load on the top. The results highlight the importance of the parameters considered in the analysis, both on the values of the failure load and on the failure mechanism. Therefore, it is found that DLO can be an useful and affordable method in order to assess the mechanical strength of masonry wall made with non-periodic textures.  相似文献   

8.
The study analyzes the anisotropy effect for ceramic masonry based on experimental tests of samples made of 25 × 12 × 6.5 cm3 solid brick elements with compressive strength fb = 44.1 MPa and cement mortar with compressive strength fm = 10.9 MPa. The samples were loaded in a single plane with a joint angle that varied from the horizontal plane. The load was applied in a vertical direction. The samples were loaded at angles of 90°, 67.5°, 45°, 22.5°, and 0° toward the bed joints. The most unfavourable cases were determined. It was observed that the anisotropy of the masonry significantly influences the load-bearing capacity of the walls depending on the angle of the compressive stresses trajectory. Approximation curves and equations for compressive strength, Young’s modulus, and Poisson’s coefficient were proposed. It was observed that Young’s modulus and Poisson’s ratio will also change depending on the trajectory of compressive stresses as a function of the joint angle. Experimental tests allowed to determine the failure mechanism in prepared specimens. The study allowed to estimate the masonry strength with the load acting at different angles toward the bed joints.  相似文献   

9.
In addition to reinforced concrete and steel buildings, a large part of the existing building stock in Europe is made of stone masonry. Prediction of the structural behavior requires the development of a systematic material characterization of the mechanical properties and structural details (units, arrangement, bonding, inter-connection). This study aims to analyze the mechanical and physical behavior of building stones in the historical city of Gjirokastër, Albania, known also as the Stone City. A thorough investigation of the regional stone quarries was performed, and the collected samples were cut into regular prismatic specimens for further analysis. The experimental campaign consisted of the determination of flexural strength and compressive strength, water absorption, porosity, specific gravity as well as structural analysis of the masonry material, using the MQI (Masonry Quality Index) method. The test results showed that there is a large scattering in the values of the mechanical and physical stone properties such as compressive strength varying from 20 to 115 MPa and flexural strength from 8 to 25 MPa. However, the analysis of the masonry material revealed a satisfactory structural performance, based on a frequent, systematic respect of the good construction practices (i.e., the rules of the art) in Gjirokastër.  相似文献   

10.
An increasing interest in the preservation of historic structures has produced a need for new methods for reinforcing curved masonry structures, such as arches and vaults. These structures are generally very ancient, have geometries and materials which are poorly defined and have been exposed to long-term historical movements and actions. Consequently, they are often in need of repair or reinforcement. This article presents the results of an experimental study carried out in the laboratory and during on-site testing to investigate the behaviour of brick masonry vaults under dynamic loading strengthened with FRPs (Fiber Reinforced Polymers). For the laboratory tests, the brick vaults were built with solid sanded clay bricks and weak mortar and were tested under dynamic loading. The experimental tests were designed to facilitate analysis of the dynamic behaviour of undamaged, damaged and reinforced vaulted structures. On-site tests were carried out on an earthquake-damaged thin brick vault of an 18th century aristocratic residence in the city of L’Aquila, Italy. The provision of FRP reinforcement is shown to re-establish elastic behavior previously compromised by time induced damage in the vaults.  相似文献   

11.
The behavior of dry stack masonry (DSM) is influenced by the interaction of the infill with the frame (especially the joints between bricks), which requires further research. This study investigates the compression and shear behaviors of DSM. First, a series of compression tests were carried out on both masonry prism with mortar (MP_m) and DSM prism (MP_ds). The failure mode of each prism was determined. Different from the MP_m, the stress-strain relationship of the MP_ds was characterized by an upward concavity at the initial stage. The compression strength of the MP_ds was slightly reduced by 15%, while the elastic modulus was reduced by over 62%. In addition, 36 shear-compression tests were carried out under cyclic loads to emphasize the influence of various loads on the shear-compression behavior of DSM. The results showed that the Mohr-Coulomb friction law adequately represents the failure of dry joints at moderate stress levels, and the varying friction coefficients under different load amplitudes cannot be neglected. The experimental setup and results are valuable for further research.  相似文献   

12.
Titanium has exceptional durability, very high specific strength, a thermal expansion coefficient similar to construction materials, low weight density, and its cost has drastically decreased over the last decades. One of the main requirements in conservation engineering is the durability of the retrofit materials and the reversibility of interventions, and a possible interesting solution is the use of titanium alloys coupled with inorganic matrices made of low-cement or lime mortars. Titanium has recently been used to reinforce important masonry and archeological monuments, but little is known about this. Its use is increasing in conservation engineering without adequate knowledge of its characteristics, grades, and properties. This paper summarizes the main features of titanium alloys, its recent applications, and discusses its drawbacks and advantages compared to other retrofit materials and methods. It is demonstrated that titanium alloys can be effectively used in many applications to reinforce masonry structures while complying with requirements in terms of durability, compatibility, and reversibility. Given its mechanical properties, its use in the repair and reinforcement of masonry structures could be particularly interesting in seismically prone areas.  相似文献   

13.
The study presents the terrestrial laser scanning (TLS) diagnostic of the clay brick masonry arched staircase in a historic building. Based on the measurements of the existing arched stair flights, 1:1 scale experimental models with and without stair treads were made. Strength tests of the models were carried out for different concentrated force locations in relation to the supporting structure. Force, deflections and reaction in the upper support of the run were measured during the tests. The influence of the masonry steps on the curved vault on the load capacity and stiffness of the run structure was analyzed. The conducted experimental investigations showed that the key element responsible for the actual load-bearing capacity and stiffness of this type of stair flights were the treads above the masonry arch.  相似文献   

14.
Most of the historical and old building stock in Europe are constructed from masonry, when brick, stones, or their combination are bound with traditional mortars. Rising damp, due to accompanying effects, is the main factor influencing the quality of indoor climate as well as having an important impact on the durability of masonry structures. In this study, new types of lightweight concrete with waste aggregate content as a suitable material for remediation of damp damaged masonries were designed and tested. Alternative aggregate served as silica sand substitution in the range of 0–100 vol.%. Basic structural properties, mechanical resistance, water, and water vapor transport properties were measured after 28 days of water curing and were compared with dense reference concrete and with traditional masonry materials as well. Moreover, the porous structure of produced concretes and changes caused by usage of alternative aggregate usage were evaluated with the mercury intrusion porosimetry (MIP) technique. Obtained experimental data showed the suitability of modified concretes with 25–50 vol.% of waste aggregate content to ensure acceptable strength and hydric properties, and these properties were found to be comparable with masonry structures and materials used in the past.  相似文献   

15.
In the strengthening interventions of past and historical masonry constructions, the non-standardized manufacture processes, the ageing and the damage of masonry units, could significantly affect the properties of the surfaces where strengthening materials are applied. This aspect requires particular care in evaluating the performance of externally bonded strengthening layers, especially with reference to the detachment mechanism. The bond response of old masonries could be very different from that occurring in new masonry units which are the ones generally considered in most of the bond tests available in technical literature. The aim of the present paper is the study of the bond behavior of historical clay bricks strengthened with steel reinforced polymers (SRP) materials. In particular, the results of an experimental study concerning new manufactured clay bricks and old bricks extracted from different historical masonry buildings are presented. The obtained results, particularly in terms of bond resistance, detachment mechanism and strain distributions, are discussed for the purpose of analyzing the peculiarities of the historical bricks in comparison with new manufactured ones. Some considerations on the efficacy of the theoretical formulations of the recent Italian code are also carried out.  相似文献   

16.
Unreinforced masonry structures are vulnerable to seismic loading due to their brittle behavior, and must therefore be strengthened. This paper presents the seismic performance of brick masonry strengthened with steel and plastic meshes. For this purpose, twenty masonry wallets of (600 × 600 × 113 mm) were constructed, keeping the same materials and workmanship. Fifteen of them were reinforced using steel and plastic meshes. These specimens were tested for in-plane static cyclic diagonal tension (shear) behavior. The critical parameters, such as shear stress, strain, failure modes, ductility, energy dissipation, and stiffness degradation were investigated. Compared to reference and plastic-reinforced specimens, the steel-reinforced samples were found to be highly effective. Furthermore, the recommended category of steel increased the shear capacity, energy dissipation, and ductility ratio by 1.3, 14, and 6.3 times, respectively.  相似文献   

17.
The application of steel fiber reinforced polymer (SRP) as a means of increasing the capacity of masonry columns is investigated in this study. The behavior of 23 solid-brick specimens that are externally wrapped by SRP sheets in low volumetric ratios is presented. The specimens are subjected to axial monotonic load until failure occurs. Two widely used types of masonry columns of differing square cross-sections were tested in compression (square and octagonal cross-sections). It is concluded that SRP-confined masonry behaves very much like fiber reinforced polymers (FRP)-confined masonry. Confinement increases both the load-carrying capacity and the deformability of masonry almost linearly with average confining stress. A comparative analysis between experimental and theoretical values computed in compliance with the Italian Council of Research (CNR) was also developed.  相似文献   

18.
In this study, experimental analysis on the compressive strength of multi-leaf thin-tile masonry is presented. A compressive strength test was carried out on thin-tile, mortar and 48 specimens with two- and three-leaf thin-tile masonry. The results obtained were compared with literature on brick masonry loaded parallel to a bed joint. Based on the results of this study, the failure mode presented the first crack in the vertical interface; this crack grew until the leaf was detached. From this point until collapse, lateral buckling of the leaves was generally observed. Therefore, the detachment compressive strength value was considered relevant. Up to this point, both masonries exhibit similar stress–strain behavior. The experimental values of the detachment compressive strength were compared with the values calculated from the equation generally used in the literature to evaluate the compressive strength of brick masonry. From the results obtained, the following conclusion can be drawn: This equation is only suitable for tree-leaf thin-tile masonry but with more relevant influence on the compressive strength of the mortar. This study concluded that only three-leaf specimens behave similarly to brick masonry loaded parallel to a bed joint. Finally, whether the failure mode was due to shear or tensile stresses in the vertical thin-tile-mortar interface cannot be identified.  相似文献   

19.
This paper investigates the mechanical contribution of an innovative coating applied on masonry wallettes compared to a traditional one. In both cases, the multifunctional coatings were insulating coatings intended for thermal refurbishment, but they could also be used to retrofit masonry. Uncoated specimens as well as coated ones were submitted to pushover tests to establish the strength gain. URM walls experienced brittle failures while the coated walls exhibited significant strength gains and strong ductility. The corresponding finite element models were developed. The behaviour of the URM walls was reproduced accurately in terms of strength and failure pattern. Models involving the coatings were used to partially retrieve the behaviour and to highlight the issues of a continuum approach.  相似文献   

20.
This paper investigates the seismic behavior of novel stone masonry joints using ductile engineered cementitious composite (ECC) as a substitute for ordinary mortar. Ten stone masonry joints with different types of mortar/ECC were tested under axial and cyclic loads. The filling materials of mortar joints tested included ordinary mortar, polymer mortar, ECC, and composite mortar with two combination proportions of ECC and ordinary mortar. The test results indicated that ECC specimens exhibited a more stable hysteretic response as well as an improvement in strength, deformation, energy dissipation, and strength degradation. The ECC mortar joints maintained integrity during the entire loading process due to the “self-confinement” effect of ECC. A partial substitution of mortar with ECC could provide effective reinforcement and confinement to prevent mortar failure and peeling, thereby allowing such specimens to approach the seismic performance of ECC specimens. Based on the trend of shear strength variations, a corresponding failure process is defined for ECC/mortar joints under cyclic and axial compressive loads, including four distinct stages: linear elastic, crack-developing stage, interface debonding, and friction sliding. New equations are proposed for predicting the shear strength and residual shear strength of the ECC/mortar joints on the basis of the test results, which are validated in the composite mortar specimens.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏