首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
The recent popularity of ingrowth or uncemented hip arthroplasties has presented problems in the radiographic diagnosis of loosening because there is no longer a cement interface in which lucencies may be seen. We evaluated a combination of positive contrast and nuclear arthrography to see whether these studies could accurately detect loosening of uncemented femoral components of hip prostheses. We performed routine contrast and nuclear arthrography in 21 patients with ingrowth total hip arthroplasties or bipolar endoprostheses. The results were surgically confirmed in 12 patients. The contrast arthrogram was true positive in 5 and false negative in 5. There were no false positives and 2 true negatives. The nuclear arthrogram was true positive in 7 patients, false negative in 3, and true negative in 2. Taken together, there was only 1 patient in whom both contrast and nuclear arthrography were false negative, and there were no false positives. Thus, when either contrast or nuclear arthrography is positive, the sensitivity of the combined procedures is 90%; when both studies are negative, the specificity is 100%. The combination of contrast and nuclear arthrography is an accurate method of determining loosening of the femoral component of an uncemented hip arthroplasty or bipolar endoprosthesis in the patient with postoperative hip pain.  相似文献   

2.
Arthroscintigraphic evaluation of the painful total hip prosthesis   总被引:1,自引:0,他引:1  
Arthroscintigraphy was performed in 19 patients with a painful total hip prosthesis by injecting both Tc-99m sulfur colloid and iodinated radiographic contrast material intra-articularly. Scintigraphic and radiographic results correlated exactly in 15 patients, with one false-negative scintigram, one false-positive scintigram, and one false-negative arthrogram. One patient was evaluated by scintigraphy alone. Although arthroscintigraphy is potentially more sensitive than conventional arthrography in the detection of femoral component loosening, acetabular component loosening cannot be evaluated by scintigraphy alone. A combination of scintigraphy and conventional arthrography appears to be the most accurate imaging method in the evaluation of hip prosthesis loosening.  相似文献   

3.
The evaluation of a painful knee prosthesis remains a difficult problem for both orthopaedic surgeons and radiologists. We have compared digital subtraction arthrography with nuclear arthrography in 7 patients with a painful knee prosthesis. Three patients showed a loose tibial component, demonstrated by both digital subtraction and nuclear arthrography. All 3 underwent revision of their prosthesis. One patient had an equivocal digital subtraction arthrogram and negative nuclear arthrogram, while both studies were negative in the 3 remaining patients. Nuclear arthrography is a simple procedure and can provide useful additional information when combined with digital subtraction arthrography.  相似文献   

4.
The evaluation of a painful knee prosthesis remains a difficult problem for both orthopaedic surgeons and radiologists. We have compared digital subtraction arthrography with nuclear arthrography in 7 patients with a painful knee prosthesis. Three patients showed a loose tibial component, demonstrated by both digital subtraction and nuclear arthrography. All 3 underwent revision of their prosthesis. One patient had an equivocal digital subtraction arthrogram and negative nuclear arthrogram, while both studies were negative in the 3 remaining patients. Nuclear arthrography is a simple procedure and can provide useful additional information when combined with digital subtraction arthrography. Offprint requests to: F.W Poon  相似文献   

5.
Radiophosphate evaluation of loose hip prostheses   总被引:1,自引:0,他引:1  
There were 23 patients who had revisions of their failed hip arthroplasties and a prior radiophosphate assessment of the joint components. In this selected group of patients the true positive incidence of abnormal scintigraphic findings for femoral component loosening was 19 out of 20 (95%) and the true negative incidence was two out of two by the criteria adopted. The true positive incidence of such findings, indicating acetabular component loosening, was seven out of seven, and the true negative was nine out of 10. Some of these patients also had contrast arthrography and the incidences of true positive and true negative findings for femoral component loosening were seven out of 15 (47%) and one out of one, respectively. Prediction of the status of the acetabulum was poorer using this technique with true positive and true negative incidences of four out of nine and two out of five, respectively.  相似文献   

6.
Limited sensitivity of ultrasound for the detection of rotator cuff tears   总被引:2,自引:0,他引:2  
Bilateral rotator cuff sonography was performed on 56 patients referred for shoulder arthrography to detect rotator cuff tears. Since one patient had bilateral arthrography there were 57 arthrograms. Twenty-seven shoulders had rotator cuff tears shown on arthrography, 15 of which were detected by sonography. Eleven were false negative by sonography, and one was indeterminate. Of the 30 shoulders with negative arthrograms, 28 had normal sonograms and two were false positive. Sensitivity was 58%, specificity was 93% and overall accuracy was 77%. The positive and negative predictive values were 88% and 72%. These results suggest that sonography has limited value in screening patients for rotator cuff tears and that a positive sonographic reading is more reliable than a negative one. Theories relating to the variable anatomic configuration of a tear are postulated to explain these results, which differ from those previously reported.  相似文献   

7.
Multicentric or multifocal breast cancer is considered as one of the limitations for sentinel lymph node (SLN) localization. We did a retrospective analysis to evaluate the success rate, sensitivity, accuracy, and negative predictive values of SLN localization in multicentric or multifocal breast lesions. METHODS: Fifty-nine patients with multifocal or multicentric breast lesions proven by either fine-needle aspiration (19/59), core biopsy (39/59), or lumpectomy (8/59) underwent SLN localization. Of these patients, 46 had SLN localization by both radiocolloid and blue dye, and 13 had SLN localization by radiocolloid alone. Approximately 10 MBq (99m)Tc-labeled unfiltered sulfur colloid in 0.3-0.4 mL were injected intradermally over the 1 or 2 breast tumor locations 2-4 h before surgery. During surgery, vital blue dye was injected intraparenchymally in 4-6 places around the tumor. All lymph nodes with counts of >10 times that of the background counts, whether or not blue dye positive, and all blue dye-positive lymph nodes, whether or not radiocolloid positive, were excised and labeled accordingly. All lymph nodes underwent frozen sectioning and were examined by hematoxylin and eosin and immunohistologic (cytokeratin) staining. RESULTS: Of the 59 patients, 48 had axillary lymph node dissection irrespective of the results of pathologic examination of the SLN. The success rate, sensitivity, negative predictive value, and accuracy were 93%, 100%, 100%, and 100% using the radiocolloid probe, 87%, 100%, 100%, and 100% using blue dye, and 93.5%, 100%, 100%, and 100% using combined methods, respectively. Concordance between blue dye and radiocolloid was 91% (the incidence of the number of sentinel nodes detected was 37.5%, 30.3%, 10.7%, and 21.4% for 1, 2, 3, and 4 or more lymph nodes, respectively). Metastatic lymph node involvement was found in 39.5% of patients. CONCLUSION: The sentinel node localization approach showed a high negative predictive value in breast cancer patients with multifocal or multicentric lesions, contrary to the common belief of significant false-negative results in these patients.  相似文献   

8.
The first clinical experience with the new contrast medium, iohexol, in shoulder arthrography is reported. A double-blind comparison of iohexol and meglumine iothalamate, a conventional medium in standard use for arthrography, was carried out in a consecutive series of 60 adult patients forming two groups of 30 subjects each. No difference in the radiographic quality was seen immediately after contrast injection but in exposures at 20 min iohexol gave a significantly better arthrographic quality. Practically no adverse effects occurred during the examinations. Although minor side effects were numerous in both groups during the two days following arthrography, they were somewhat more frequent in patients given iothalamate.  相似文献   

9.
间接法MRI膝关节造影对半月板撕裂的评价   总被引:7,自引:0,他引:7  
目的 评价间接法MRI膝关节造影对半月板撕裂的诊断价值。方法 回顾性分析 75例常规MRI膝关节扫描和 6 4例间接法MRI膝关节造影病例资料 ,以膝关节镜检查为诊断金标准 ,对比分析常规MRI和间接法MRI膝关节造影对半月板撕裂的诊断。结果 间接法MRI膝关节造影对内侧半月板撕裂的诊断敏感性、特异性、准确性、阳性预测值和阴性预测值分别为 72 %,10 0 %,89.1%,10 0 %和 84.8%;对外侧半月板撕裂分别为 83.8%,90 .9%,87.5 %,89.6 %和 85 .7%。与常规MRI比较 ,间接法MRI膝关节造影对内外侧半月板撕裂的诊断能力都没有统计学差异。结论 尽管间接法MRI膝关节造影对内外侧半月板撕裂诊断价值很高 ,但与常规MRI比较没有统计学差异。  相似文献   

10.
Preoperative shoulder arthrography was performed on 34 patients with painful arc syndromes. Rotator cuff rupture was diagnosed in 20 cases. Out of these the arthrography correctly showed rupture in 17 cases, while in one case rupture was not seen and two examinations were unsuccessful. Rotator cuff rupture was not found in 14 cases at operation. Of these, arthrography had been negative in eight cases and in six cases the rupture had merely been suspected. Sensitivity of shoulder arthrography in showing rotator cuff rupture was thus 85%, specificity 57% and accuracy 74%. The biceps tendon was intact in all cases with rotator cuff rupture. So-called "bicipital leakage" was seen in four cases, but its significance remains unclear.  相似文献   

11.
Twenty-five patients with symptomatic uncemented total hip components were studied with contrast arthrography prior to surgical exploration. All but one had uncemented femoral stems and 16 had an uncemented acetabular component. As judged by the findings at surgery, on the femoral side the sensitivity, specificity, and accuracy of arthrography were 57%, 60%, and 58% respectively. There was a relatively high incidence of both false positives (17%) and false negatives (25%). On the acetabular side sensitivity, specificity, and accuracy were 29%, 89%, and 62.5%. False negatives were common (31%), while there was only one false positive. The results in this small series show that arthrography has distinct limitations in identifying the fixation status of uncemented total hip components.  相似文献   

12.

Purpose

The purpose of the study is to determine the usefulness of magnetic resonance arthrography (MRA) in diagnosis and grading of superior labrum anterior to posterior (SLAP) lesions of the Glenoid Labrum Compared with surgery

Material and methods

This was a prospective study including fifty nine clinically diagnosed SLAP patients. The study was done during the period from January 2008 to June 2010. All patients were submitted to history taking, clinical examination and conventional MRI examination of the shoulder, MRA was done in patients with negative conventional MRI, all of these patients underwent arthroscopy for diagnosis wither open or arthroscopy for diagnosis and treatment and results were compared with MRA findings.

Main outcome measures

Sensitivity, specificity, positive and negative predictive values, and overall accuracy of MR arthrography in detection and grading of SLAP lesions of the gelnoid labrum.

Results

Out of fifty nine patients, 25 patients had positive MR findings in conventional MRI, and 34 patients had negative MR findings, who underwent MR arthrography; 10 out of them had normal arthrogram (only 6 of them underwent arthroscopy), 22 had SLAP (superior labrum anterior to posterior) lesions, one had Bankart's lesion and one had internal impingement syndrome. These results were compared with arthroscopy results.The overall sensitivity of MRA in detection of SLAP lesions was 90% while the specificity was 50%, negative predictive value (NPV) was 66.6% and positive predicative value (PPV) was 81.8%. MRA and arthroscopy results were concurrent in 79.3% patients.

Conclusion

MR arthrography is a sensitive minimally invasive technique for detection and grading of SLAP lesions, it can help in avoiding patients unnecessary diagnostic arthroscopy.  相似文献   

13.
Nuclear medicine has proven to have a valuable role in the evaluation of osseous metallic implants, particularly with joint prostheses, but can assist with evaluation of other appliances as well. The nuclear arthrogram has become an invaluable adjunct to simultaneously performed radiographic contrast arthrography. This application has been best evaluated in what is one of the most common of orthopedic prosthesis problems, namely, loosening of total hip prostheses. Experience indicates that both sensitivity and specificity of loosening of the femoral component can be increased to over 90% through combined use of nuclear with radiographic contrast arthrography. Furthermore the combination of routine skeletal scintimaging with the nuclear arthrogram adds a significant dimension to precise localizing of the nuclear arthrographics agent In-111 chloride. Nuclear medicine also plays an important role in further evaluating the presence of infection associated with metallic implants with In-111 WBC preparations being superior to Ga-67 as the radiopharmaceutical tracer. Infection has been detected with a sensitivity of 73% and a specificity of 93% in our series using combined In-111 WBC and simultaneous skeletal imaging with conventional Tc-99m MDP. Acute infections are more readily identifiable than chronic in association with prostheses.  相似文献   

14.
OBJECTIVE: To summarize and compare the diagnostic accuracy of contrast and subtraction arthrography in the assessment of aseptic loosening of total hip arthroplasties. DESIGN: This meta-analysis was performed using methods described by the Cochrane Methods Group on Systematic Reviews of Screening and Diagnostic Tests. We included original, English-language papers published between January 1975 to October 2004 that examined contrast-enhanced arthrography with or without subtraction for diagnosis of loosening of total hip prostheses. A qualitative and quantitative analysis was performed by two investigators. RESULTS: With regard to the acetabular component, pooled sensitivity and specificity for contrast arthrography was 70% (95% confidence interval, 52-84) and 74% (95% CI, 53-87), respectively. Subtraction arthrography had a significantly higher sensitivity of 89% (95% CI, 84-93) (p=0.01), with a similar specificity of 76% (95% CI, 68-82). For the femoral component, pooled sensitivity and specificity for contrast arthrography were 63% (95% CI, 53-72) and 78% (95% CI, 68-86). Pooled estimates for subtraction arthrography revealed a significantly higher sensitivity of 86% (95% CI, 74-93) (p=0.003). Specificity was 85% (95% CI, 77-91) and was similar to the data of contrast arthrography (p=0.23). CONCLUSION: Using the present data we found that the subtraction arthrography is a sensitive technique for detection of loosening of total hip prostheses, offering added value over contrast arthrography, especially for evaluation of the femoral component.  相似文献   

15.
To assess the value of tenography of the peroneal tendon sheaths and of arthrography of the tibiotalar joint for the diagnosis and classification of recent ruptures of the lateral ankle ligaments, the authors performed a prospective study on 108 patients with inversion trauma of the ankle. All patients underwent tenography. Arthrography was performed if results of tenography were negative. All patients with positive tenographic or arthrographic results underwent surgery. Tenography proved to be reliable in the diagnosis of injuries of the calcaneofibular ligament (sensitivity, 88%; specificity, 87%-94%). The positive predictive value of tenography in combination with arthrography was 100% for the diagnosis of lateral ligament ruptures. The authors conclude that a combination of arthrography and tenography is a reliable method for diagnosing recent ruptures of the lateral ankle ligaments and for differentiating between isolated ruptures of the talofibular ligament and combined lesions of both the talofibular and the calcaneofibular ligaments.  相似文献   

16.
PURPOSE: Radiation synovectomy is frequently combined with intraarticular corticosteroid injection in the treatment of rheumatoid arthritis to reduce local inflammation and lymphatic clearance of radiocolloid. However, this practice is not universally accepted because corticosteroids have local and systemic toxicity such as osteonecrosis and cartilage damage and whether simultaneous corticosteroid injection together with radiocolloids is necessary in other forms of chronic synovitis like patients with hemophilia remains to be determined. MATERIALS AND METHODS: In this study, we performed radiosynoviorthesis in 14 joints of 12 patients with hemophilia with chronic knee synovitis without corticosteroid coadministration and measured radiocolloid leakage from the joint space. Five mCi Y-90 radiocolloid was injected under local anesthesia and the needle was flushed with additional lidocaine injection instead of corticosteroid. The joint was then manipulated through a full range of extension and flexion to distribute the particles homogeneously throughout the joint space. The joint was then splinted for 48 hours to minimize leakage from the joint space. After the immobilization period, radiocolloid leakage was evaluated using a gamma camera with a 20% window centered over the maximum Bremsstrahlung photopeak of Y-90. Regions of interest were drawn to the injection site on the knee joint and to the ipsilateral inguinal lymph node area. Leakage of radiocolloid was calculated by dividing the background-corrected counts/pixel at the inguinal region by the counts/pixel at the injection site. RESULTS: One of 12 patients who had knee arthroplasty was previously found to have a high amount of leakage. In this patient, 70% of radiocolloid at the injection site drained into the pelvic lymph nodes. In the remaining 11 patients, no lymph nodes were visualized in the groin area and the measured average leakage for these patients was 2.3% (range, 0-13). CONCLUSION: We concluded that in cases of appropriate particle size and strict immobilization of knee joints, leakage of radiocolloid was minimal and steroid coinjection might not be necessary for radiosynoviorthesis of patients with hemophilia with chronic knee synovitis.  相似文献   

17.
Plain radiographs and wrist arthrography of 11 patients with non-united fractures of the scaphoid were retrospectively studied. The arthrographic feature of non-union was found to be opacification of the fracture line and, secondly, of the midcarpal compartment, whereas in patients with fibrous or cartilaginous union no opacification of the fracture line was obtained. There was no single plain radiographic feature that could distinguish non-union from fibrous or cartilaginous union.  相似文献   

18.
PURPOSE: To prospectively investigate the accuracy of conventional magnetic resonance (MR) imaging, direct MR arthrography, and indirect MR arthrography in assessment of possible recurrent or residual meniscal tears. MATERIALS AND METHODS: Three hundred sixty-four patients who had previously undergone meniscal preservation surgery were prospectively examined with conventional MR imaging, indirect MR arthrography, and direct MR arthrography. Ninety-four patients (104 postoperative menisci) underwent subsequent second-look arthroscopic surgery. Each case was evaluated for (a) surfacing intrameniscal intermediate- or T1-weighted signal intensity, (b) surfacing intrameniscal T2-weighted signal intensity, (c) morphologic changes beyond those expected postoperatively, (d) joint effusion on conventional MR or indirect MR arthrographic studies, and (e) overall presence or absence of recurrent meniscal tear. RESULTS: Seventy-one arthroscopically proved recurrent meniscal tears were found. In the diagnosis of recurrent meniscal tears, sensitivity, specificity, positive predictive value, negative predictive value, and accuracy were 86%, 67%, 83%, 71%, and 80%, respectively, for conventional MR imaging; 83%, 78%, 90%, 64%, and 81%, respectively, for indirect MR arthrography; and 90%, 78%, 90%, 78%, and 85%, respectively, for direct MR arthrography. No significant difference in the diagnostic accuracy of one method relative to another was observed (P >.54). Surfacing intrameniscal T2-weighted signal intensity was the most specific sign, with the highest positive predictive value of a recurrent tear. CONCLUSION: Although a small incremental increase in accuracy is associated with the use of direct MR arthrography over conventional MR imaging and indirect MR arthrography, no significant difference in diagnostic accuracy among the three techniques was demonstrated for detection of recurrent or residual meniscal tear.  相似文献   

19.
Rotator cuff tear: clinical experience with sonographic detection   总被引:5,自引:0,他引:5  
Soble  MG; Kaye  AD; Guay  RC 《Radiology》1989,173(2):319-321
Between June 1986 and April 1988, 86 sonographic examinations of the shoulder were performed on patients suspected of having rotator cuff tears. Major sonographic diagnostic criteria included (a) a well-defined discontinuity usually visible as a hypoechoic focus within the cuff, (b) nonvisualization of the cuff and (c) an echogenic focus within the cuff. Seventy-five patients underwent both sonography and arthrography. Compared with arthrography alone, ultrasound examinations enabled detection of 92% of rotator cuff tears (24 of 26 tears), with a specificity of 84% and a negative predictive value of 95%. Correlation was obtained in 30 of these patients who underwent surgery for rotator cuff tear or other soft-tissue abnormality. In this group, the sensitivity of sonography for detection of a tear was 93%, with a specificity of 73%, while for arthrography sensitivity was 87% and specificity was 100%. These data indicate that sonography is a useful, noninvasive screening procedure for patients suspected of having rotator cuff injury.  相似文献   

20.
Three vertebral lesions, two compression fractures, and one metastasis in two patients, were incidentally demonstrated during Tc-99m sulfur colloid liver-spleen studies. Although the scintigraphic photon-deficient area could not be differentiated due to the metastasis and the compression fracture, the abnormal radiocolloid findings of vertebrae may lead to further studies using Tc-99m diphosphonate, Ga-67, radiographic studies, and/or biopsy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号