首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Previously reported antibiotic-impregnated cement strengths have been based on uniaxial and fatigue testing methodologies. These methods may not provide an accurate characterization of bone cement's true load-bearing capacity in total joint replacement (TJR). The present study utilized biaxial testing to report on the properties of antibiotic-impregnated cement. Test groups included: PMMA mixed with Vancomycin, Gentamicin, Tobramycin, or no antibiotic (control). In comparison to the control group, PMMA samples mixed with powdered gentamicin resulted in an increase in the mean elastic modulus by 6.50% versus a drop noted with powdered vancomycin and tobramycin by 2.65 and 1.37% respectively. The mean elastic modulus in samples containing liquid gentamicin dropped by 11.6%. This study supports the continued use of powdered antibiotics when clinically indicated, but suggest caution in the use of liquid gentamicin in TJR.  相似文献   

2.
背景:临床研究表明,聚甲基丙烯酸甲酯骨水泥的生物活性较差,不太适合单独用于经皮椎体成形。 目的:探索一种能满足经皮椎体成形填充材料理化要求的具备生物活性的多孔复合材料。 方法:将碳酸氢钠、硫酸钙-脱钙骨基质颗粒粉末和聚甲基丙烯酸甲酯骨水泥按不同质量比例(1∶40∶60,0∶40∶60,   1∶0∶100)混合构成A、B、C 3种复合材料。检测各种复合物凝固时间、聚合温度、抗稀散性及成型材料的抗压性,以扫描电镜观察其超微结构。 结果与结论:A、B组与C组材料的凝固时间、聚合温度、抗压强度比较差异有显著性意义,但均符合经皮椎体成形填充材料基本要求,抗稀散性均良好。扫描电镜示A组结合较B、C组材料疏松,材料内部孔隙较多。提示复合材料A具有良好的理化性能,能满足作为经皮椎体成形填充材料的基本条件,且具备较好的孔隙结构,可以进一步研究其组织相容性、可降解性、骨传导性及骨诱导性等生物学性能。  相似文献   

3.
Dunne NJ  Orr JF 《Biomaterials》2001,22(13):1819-1826
Palacos R bone cement was prepared using three commercially available mixing techniques, first generation, second generation and third generation, to determine the mechanical properties and porosity contents of the bone cement. The compressive strengths, bending strengths and flexural moduli were expressed as a function of void content. The volume of pores within the cement structure was found to be a contributing factor to the physical properties of acrylic bone cement. The lower the volume of voids in the cement the better the compressive and flexural properties, hence stronger bone cement. It was found that the best results were obtained from cement that had been mixed using the Mitab Optivac or Summit HiVac Syringe systems at a reduced pressure level of between -72 and -86 kPa below atmospheric pressure, resulting in cement of porosity 1.44-3.17%; compressive strength 74-81 MPa; flexural modulus 2.54-2.60 GPa; and flexural strength 65-73 MPa.  相似文献   

4.
A novel bioactive bone cement (GBC) was developed with newly designed bioactive MgO-CaO-SiO(2)-P(2)O(5)-CaF(2) glass beads as the inorganic filler and high molecular weight poly(methyl methacrylate) as the organic matrix. The purpose of this study was to examine the relationship between the amount of the silane coupling agent (gamma-methacryloxy propyl trimethoxy silane) used to treat the glass beads and the mechanical and biological properties of the resultant bone cement. Serial changes in the cement over time were also investigated. Five different kinds of cement, in which the glass beads were treated with different amounts of the coupling agent, were prepared. The quantities of the coupling agent were 0 (control), 0.1, 0.2, 0.5, and 1.0% (w/w) of the glass beads, and the cements were designated GBCs0, GBCs0.1, GBCs0.2, GBCs0.5, and GBCs1.0, respectively. After soaking in water at 75 degrees C for 5 days, GBCs0.1 and GBCs0.2 had significantly higher bending strengths than the other cements. Each GBC was packed into intramedullar canals of rat tibiae to evaluate osteoconductivity, as determined by affinity indices. Rats were killed 4 and 8 weeks after the operation. The affinity index was calculated for each GBC and equaled the length of bone in direct contact with the cement and was expressed as a percentage of the total length of the cement surface. Histologically, new bone had formed along all of the GBC surfaces within 4 weeks. At each time interval, a decreasing trend in the affinity index of GBC was found as the amount of the coupling agent increased. At 8 weeks, no significant change in the affinity index occurred when the amount of the coupling agent increased from 0 to 0.2%, whereas a significant decrease in the affinity index was observed when the amount of the coupling agent increased from 0 to 0.5 or 1.0%. The affinity indices for all the GBCs increased significantly up to 8 weeks. When both the mechanical properties and osteoconductivity were taken into consideration, GBCs0.1 and GBCs0.2 were the best cements, and they showed excellent osteoconductivity and strong enough mechanical properties for clinical use.  相似文献   

5.
PMMA bone cements (Refobacin-Palacos R, Sulfix 6, AKZ, and CMW bone cement, types I and II), from six different clinics, were investigated in three stages. In the first stage, studies of density, hardness, flexural strength, and compressive strength were made, as well as molecular weight measurements and microscopic investigations. These studies reflected the current state of techniques of application used in operating theaters. They revealed wide variations in the properties of the materials studied. Secondly, a comprehensive study of the process-technology in the laboratory was performed. The following variables were investigated or discussed: mixing vessel, order of the individual components, mixing time, rate of mixing, pressure application on the mixed bone cement, kneading, cement thickness, pouring into the syringe, contact force during polymerization, and preparation quantity. The third stage involved the development and clinical testing of an improved mixing technique. Using this improved mixing technique, all three selected clinics achieved far better results with reduced variability. A comparison between a centrifuging technique after mixing and our improved, but conventional, mixing technique, displays advantages for the latter. The question regarding a correlation between cement specimens of high porosity and early implant loosening could not be answered on the basis of the 43 PMMA bone cement explants investigated (implanted 6 months to 15 years). In some cases, the studies revealed that the bone cement manufacturers should be required to revise and quantify existing instructions for use. The users, on the other hand, should give more consideration to the mixing technique and its consequences.  相似文献   

6.
Vertebral cement augmentation is reported to be a safe and effective technique for providing stabilization and pain relief. However, adjacent intervertebral discs may be at risk of accelerated degeneration as a result of aggravated nutritional constraints. Therefore, we investigated the effects of injecting polymethylmethacrylate (PMMA) into three adjacent lumbar vertebrae on intervertebral disc and vertebral bone tissue in 12 skeletally mature sheep. After 6 and 12 months of augmentation, the sheep were euthanized and their spines were processes for histological evaluation. Semiquantitative histomorphological analysis of discs and endplates was conducted using published criteria. Histomorphological changes in the augmented bone were assessed qualitatively. Approximately 80% of the length of the endplates was in contact with PMMA. However, there was no significant difference between the histopathological score of the discs adjacent to augmented vertebrae and the score of the control discs. Bone tissue reaction to PMMA was characterized by a thin fibrous tissue layer and occasional foreign-body reactions. New bone formation was present in all augmented vertebrae. Concerns about aggravation of disc degeneration as a result of vertebral cement augmentation seem to be unsubstantiated. Furthermore, adverse effects of PMMA cement on bone biology do not seem to be a relevant issue.  相似文献   

7.
The effect of surface modification of polymer filler on the static mechanical properties of acrylic bone cement was studied. The surface of polymer beads was modified with carboxylic and amino groups by photochemical reaction with azide compounds. Monomer modifiers (maleic anhydride, methacrylic acid and p-aminostyrene) are attached to the functionalized surface of polymer beads. Functional allyl groups, which are capable of the graft polymerisation reaction, are attached to the surface via photochemical reaction with N-(2-nitro-4-azidophenyl)-N-(-propen) amine. This approach to bone cement provides the additional covalent bonds between the polymer beads and the inter-bead matrix. The static mechanical properties of bone cements containing modified polymer beads were investigated and compared with the static mechanical properties of unmodified cements. The absolute values of compressive strength for the modified and unmodified cements were found to be similar. An increase in flexural strength for the modified cements (dry and after water storage) was observed. The structure of the surface functional groups affects the methyl methacrylate grafting resulting in a higher value of flexural strength for the maleic anhydride- and p-aminostyrene-modified cements. The scanning electron microscopy examination of the fracture surface of the cement samples showed an improvement of the adhesion between the beads and the matrix after modification.  相似文献   

8.
The effect of surface modification of polymer filler on the static mechanical properties of acrylic bone cement was studied. The surface of polymer beads was modified with carboxylic and amino groups by photochemical reaction with azide compounds. Monomer modifiers (maleic anhydride, methacrylic acid and p-aminostyrene) are attached to the functionalized surface of polymer beads. Functional allyl groups, which are capable of the graft polymerisation reaction, are attached to the surface via photochemical reaction with N-(2-nitro-4-azidophenyl)-N-(-propen) amine. This approach to bone cement provides the additional covalent bonds between the polymer beads and the inter-bead matrix. The static mechanical properties of bone cements containing modified polymer beads were investigated and compared with the static mechanical properties of unmodified cements. The absolute values of compressive strength for the modified and unmodified cements were found to be similar. An increase in flexural strength for the modified cements (dry and after water storage) was observed. The structure of the surface functional groups affects the methyl methacrylate grafting resulting in a higher value of flexural strength for the maleic anhydride- and p-aminostyrene-modified cements. The scanning electron microscopy examination of the fracture surface of the cement samples showed an improvement of the adhesion between the beads and the matrix after modification.  相似文献   

9.
背景:目前经皮椎体成形技术已广泛应用于治疗老年骨质疏松椎体压缩性骨折以及椎体肿瘤并取得良好疗效,但仍有一些问题需关注和探讨。 目的:观察聚甲基丙烯酸甲酯骨水泥对脊柱转移瘤细胞周期变化和细胞凋亡的影响,分析其对脊柱转移瘤的体外抗肿瘤效应。 方法:原代培养脊柱转移瘤细胞,将其分为对照组、拉丝期聚甲基丙烯酸甲酯骨水泥组、冷却后聚甲基丙烯酸甲酯骨水泥组,药物处理24 h后利用流式细胞术观察凋亡率以及细胞周期,通过SYBR GreenⅠ荧光实时定量-聚合酶链反应法检测肿瘤细胞Bax和Caspase-3 mRNA表达的变化。 结果与结论:聚甲基丙烯酸甲酯骨水泥有促进脊柱转移瘤细胞凋亡的作用,对照组、拉丝期聚甲基丙烯酸甲酯骨水泥组、冷却后聚甲基丙烯酸甲酯骨水泥组的凋亡率分别为(3.80±1.09)%,(43.46±8.55)%,(28.77±9.39)%,两骨水泥组均能明显提高细胞凋亡率,拉丝期聚甲基丙烯酸甲酯骨水泥组作用更明显(P < 0.05)。两骨水泥组均能明显减少G0/G1期细胞,增加S期细胞(P < 0.05)。拉丝期聚甲基丙烯酸甲酯骨水泥组作用于脊柱转移瘤细胞后Bax、Caspase-3 mRNA的表达显著高于对照组(P < 0.05)。提示聚甲基丙烯酸甲酯骨水泥可在体外细胞水平诱导肿瘤细胞凋亡,拉丝期聚甲基丙烯酸甲酯骨水泥作用更加显著。   相似文献   

10.
背景:聚甲基丙烯酸甲酯骨水泥是其最常用的一种填充材料,但由于其存在聚合时放热、单体毒性等缺点,所以目前出现了以Cortoss为代表的生物新型骨水泥。 目的:对比两种骨水泥在体外的力学性能。 方法:将聚甲基丙烯酸甲酯与新型骨水泥Cortoss按照ISO5833:2002标准分别制作成抗压及抗弯模型,将制作的模型使用生物力学机测试两种骨水泥的抗弯及抗压模量,同时在制模过程中测量骨水泥聚合温度。 结果与结论:与聚甲基丙烯酸甲酯骨水泥比较,Cortoss骨水泥在聚合过程中最高温度较低、抗压强度较强、抗弯模量降低,差异均有显著性意义(P < 0.05),而抗弯强度间差异无显著性意义(P > 0.05)。说明Cortoss生物力学强度优于聚甲基丙烯酸甲酯骨水泥,由于Cortoss在聚合时放热较少,所以其用于手术时有较好的安全性。   相似文献   

11.
We took three types of bioactive bone cement (designated AWC, HAC, and TCPC), each with a different bioactive filler, and evaluated the influence of each filler on the mechanical properties and osteoconductivity of the cement. The cements consisted of bisphenol-a-glycidyl methacrylate-based (Bis-GMA based) monomers as an organic matrix, with a bioactive filler of apatite/wollastonite containing glass-ceramic (AW-GC) or sintered hydroxyapatite (HA) or beta-tricalcium phosphate (beta-TCP) powder. Each filler was mixed with the monomers in proportions of 50, 70, and 80% (w/w), giving a total of nine cement subgroups. The nine subgroups were designated AWC50, AWC70, AWC80, HAC50, HAC70, HAC80, TCPC50, TCPC70, and TCPC80. The compressive and bending strengths of AWC were found to be higher than those of HAC and TCPC for all bioactive filler contents. We also evaluated the cements in vivo by packing them into the intramedullary canals of rat tibiae. To compare the osteoconductivity of the cements, an affinity index was calculated for each cement; it equaled the length of bone in direct apposition to the cement, expressed as a percentage of the total length of the cement surface. Microradiographic examination up to 26 weeks after implantation revealed that AWC showed a higher affinity index than HAC and TCPC for each filler content although the affinity indices of all nine subgroups (especially the AWC and HAC subgroups) increased with time. New bone had formed along the AWC surface within 4 weeks, even in the cement containing AW-GC filler at only 50% (w/w); observation of the cement-bone interfaces using a scanning electron microscope showed that all the cements had directly contacted the bone. At 4 weeks the AWC had bonded to the bone via a 10 micron-thick reactive layer; the width of the layer, in which partly degraded AW-GC particles were seen, became slightly thicker with time. On the other hand, in the HAC- and TCPC-implanted tibiae, some particles on the cement surface were surrounded by new bone and partly absorbed or degraded. The results suggest that the stronger bonding between the inorganic filler and the organic matrix in the AWC cements gave them better mechanical properties. The results also indicate that the higher osteoconductivity of AWC was caused by the higher reactivity of the AW-GC powder on the cement surface.  相似文献   

12.
Calcium phosphate cement (CPC) can conform to complex bone cavities and set in-situ to form bioresorbable hydroxyapatite. The aim of this study was to develop a CPC-collagen composite with improved fracture resistance, and to investigate the effects of collagen on mechanical and cellular properties. A type-I bovine-collagen was incorporated into CPC. MC3T3-E1 osteoblasts were cultured. At CPC powder/liquid mass ratio of 3, the work-of-fracture (mean +/- sd; n = 6) was increased from (22 +/- 4) J/m(2) at 0% collagen, to (381 +/- 119) J/m(2) at 5% collagen (p < or = 0.05). At 2.5-5% of collagen, the flexural strength at powder/liquid ratios of 3 and 3.5 was 8-10 MPa. They matched the previously reported 2-11 MPa of sintered porous hydroxyapatite implants. SEM revealed that the collagen fibers were covered with nano-apatite crystals and bonded to the CPC matrix. Higher collagen content increased the osteoblast cell attachment (p < or = 0.05). The number of live cells per specimen area was (382 +/- 99) cells/mm(2) on CPC containing 5% collagen, higher than (173 +/- 42) cells/mm(2) at 0% collagen (p < or = 0.05). The cytoplasmic extensions of the cells anchored to the nano-apatite crystals of the CPC matrix. In summary, collagen was incorporated into in situ-setting, nano-apatitic CPC, achieving a 10-fold increase in work-of-fracture (toughness) and two-fold increase in osteoblast cell attachment. This moldable/injectable, mechanically strong, nano-apatite-collagen composite may enhance bone regeneration in moderate stress-bearing applications.  相似文献   

13.
Reaction of mature bone and its vasculature to 3.33 +/- 0.19 microm polymethylmethacrylate (PMMA) particles at a concentration of 2.5 x 10(8)/cc was measured using optical bone chamber implant intravital microscopy. Twelve adult female New Zealand White rabbits were divided into six receiving Healon alone (controls) and six receiving Healon plus PMMA. The particles were introduced to the bone chamber compartment after removing its overlying optical element, which was immediately reinstalled. Reaction was monitored weekly over a 6-week period using video and photographic imaging. Bone was labeled before treatment with oxytetracycline and after treatment with alizarin complexone. Perfusing blood was labeled with fluorescein isothiocyanate dextran-70 kDa (FITC-D70). Parameters measured were net bone resorption, from black and white images, bone turnover, from color images, vascularity, and average vessel caliber. Neither bone turnover nor vessel caliber were significantly affected at the p < or = 0.050 level over time. In contrast, bone resorption was significantly greater and vascularity significantly less in the presence of PMMA. It was inferred that any differences in bone turnover were masked by resorption of new bone. It was concluded that the lack of a PMMA effect on average vessel caliber meant that the vascularity effects were not due to angiogenesis, but to vessel recruitment (or its opposite), an effect more consistent with inflammation than repair. The lack of vascularity increase in PMMA-treated compartments also suggested that increased resorption was a local phenomenon, because blood supply had not increased to provide the extra osteoclasts required for observed net bone loss.  相似文献   

14.
Deformation behavior of polymethyl methacrylate (PMMA) bone cement is explored using microindentation. Two types of PMMA bone cement were prepared. Vacuum treated samples were subjected to the degassing of the material under vacuum of 270 mbar for 35 s, followed by the second degassing under vacuum of 255 mbar for 35 s. Air-cured samples were left in ambient air to cool down and harden. All samples were left to age for 6 months before the test. The samples were then subjected to the indentation fatigue test mode, using sharp Vickers indenter. First, loading segment rise time was varied in order to establish time-dependent behavior of the samples. Experimental data showed that viscous part of the deformation can be neglected under the observed test conditions. The second series of microindentation tests were realized with variation of number of cycles and indentation hardness and modulus were obtained. Approximate hardness was also calculated using analysis of residual impression area. Porosity characteristics were analyzed using CellC software. Scanning electron microscopy (SEM) analysis showed that air-cured bone cement exhibited significant number of large voids made of aggregated PMMA beads accompanied by particles of the radiopaque agent, while vacuum treated samples had homogeneous structure. Air-cured samples exhibited variable hardness and elasticity modulus throughout the material. They also had lower hardness values (approximately 65-100 MPa) than the vacuum treated cement (approximately 170 MPa). Porosity of 5.1% was obtained for vacuum treated cement and 16.8% for air-cured cement. Extensive plastic deformation, microcracks and craze whitening were produced during indentation of air-cured bone cement, whereas vacuum treated cement exhibited no cracks and no plastic deformation.  相似文献   

15.
Shi Z  Neoh KG  Kang ET  Wang W 《Biomaterials》2006,27(11):2440-2449
Although total joint replacement has become commonplace in recent years, bacterial infection remains a significant complication following this procedure. One approach to reduce the incidence of joint replacement infection is to add antimicrobial agents to the bone cement used to fix the implant. In this in vitro study, we investigated the use of chitosan nanoparticles (CS NP) and quaternary ammonium chitosan derivative nanoparticles (QCS NP) as bactericidal agents in poly(methyl methacrylate) (PMMA) bone cement with and without gentamicin. The antibacterial activity was tested against Staphylococcus aureus (S. aureus) and Staphylococcus epidermidis (S. epidermidis). A 10(3)-fold reduction in the number of viable bacterial cells upon contact with the surface was achievable using QCS NP at a nanoparticle/bone cement weight ratio of 15%. The inhibition of S. aureus and S. epidermidis growth on the surface of the CS NP and QCS NP-loaded bone cements was clearly shown using the LIVE/DEAD Baclight bacterial viability kits and fluorescence microscopy. The CS NP and QCS NP also provided a significant additional bactericidal effect to gentamicin-loaded bone cement. The antibacterial effectiveness remained high even after the modified bone cements had been immersed for 3 weeks in an aqueous medium. No cytotoxic effect of the CS NP- and QCS NP-loaded cements was shown in a mouse fibroblast MTT cytotoxicity assay. Mechanical tests indicated that the addition of the CS and QCS in nanoparticulate form allowed the retention of a significant degree of the bone cement's strength. These results indicate a new promising strategy for combating joint implant infection.  相似文献   

16.
The aim of the present study was to determine the influence of surface treatment on the mechanical properties of strontium-containing hydroxyapatite (Sr-HA) bioactive bone cement. Previously we developed an injectable bioactive cement (SrHAC) system composed of Sr-HA powders and bisphenol A diglycidylether dimethacrylate (Bis-GMA). In this study, the Sr-HA powder was subjected to surface treatment using acrylolpamidronate, a bisphosphonate derivative, which has a polymerizable group, to improve the interface between inorganic filler and organic matrix by binding Sr-HA and copolymerizing into the matrix. After surface treatment, the compression strength, bending strength, and stiffness of the resulting composites were defined by using a material testing machine (MTS) according to ISO 5833. The fracture surface of the bone cement specimen was observed with a scanning electron microscope. Invitro cytotoxicity of surface-treated SrHAC was also studied using a tetrazolium-based cell viability assay (MTS/pms) on human osteoblast-like cells, the SaOS-2 cell line. Cells were seeded at a density of 10(4)/mL and allowed to grow in an incubator for 48 h at 37 degrees C. Results indicated that after surface treatment, the compression strength and stiffness significantly improved by 22.68 and 14.51%, respectively. The bending strength and stiffness of the bioactive bone cement also showed 19.06 and 8.91% improvements via three-point bending test. The fracture surface micromorphology after compression and bending revealed that the bonding between the resin to surface-treated filler considerably improved. The cell viability indicated that the treated particles were nontoxic and did not inhibit cell growth. This study demonstrated a new surface chemistry route to enhance the covalent bonds between inorganic fillers and polymer matrix for improving the mechanical properties of bone cement. This method not only improves the overall mechanical performance but also increases osteoblastic activity.  相似文献   

17.
A bioactive bone cement (designated GBC), consisting of bioactive glass beads as an inorganic filler and poly(methyl methacrylate) (PMMA) as an organic matrix, has been developed. The purpose of the present study was to examine the effect of the size of the glass beads added as a filler to GBC on its mechanical properties and osteoconductivity. Serial changes in GBC with time were also examined. Four different sizes of beads (mean diameters 4, 5, 9, and 13 microm) consisting of MgO-CaO-SiO(2)-P(2)O(5)-CaF(2) glass were added to four GBC mixes in a proportion of 70 wt %. The bending strength of GBC increased as the mean size of the glass beads decreased. The four GBC mixes were packed into the intramedullary canals of rat tibiae to evaluate osteoconductivity, as determined by an affinity index. Rats were sacrificed at 4 and 8 weeks after surgery. The affinity index, which equaled the length of bone in direct contact with the cement surface expressed as a percentage of the total length of the cement surface, was calculated for each cement at each interval. Histologically, new bone had formed along the surface of all types of GBC within 4 weeks. At each time interval, there was a trend for the affinity index of GBC to increase as the mean glass bead size decreased. The affinity indices for all types of GBC increased significantly with time up to 8 weeks. The handling properties of GBC were comparable to those of conventional PMMA bone cement. We concluded that, considering both mechanical properties and osteoconductivity, GBC made with smaller sized glass beads as filler was the most suitable cement. GBC shows promise as an alternative bone cement with improved properties compared to conventional PMMA bone cement.  相似文献   

18.
The influence of the storage temperature of the cement constituents prior to mixing (21 vs. 4 degrees C) and the mixing method (hand mixing vs. vacuum mixing) on the uniaxial tension-compression fatigue performance and porosity of Palacos R acrylic bone cement was studied. The fatigue results were analyzed using the three-parameter Weibull equation. The fatigue performance was expressed as an index I, which was defined as the product of the Weibull characteristic fatigue life and the square root of the Weibull slope. Statistical analyses of these results show that although the mixing method (for a given storage temperature) exerts a significant influence on the fatigue performance and areal porosity, the effect of storage temperature (for a given mixing method) on either of these parameters is not significant.  相似文献   

19.
A new bioactive bone cement, designated GBC, has been developed. It consists of polymethyl methacrylate (PMMA) as an organic matrix and bioactive glass beads as an inorganic filler. The bioactive beads, consisting of MgO--CaO--SiO(2)--P(2)O(5)--CaF(2) glass, have been newly designed, and a novel PMMA powder was selected. The purpose of the present study was to evaluate the effects on mechanical properties and osteoconductivity of adding a phosphoric ester (PE) monomer to the cement as an adhesion-promoting agent. Four kinds of cements were prepared: GBC, GBC with PE (designated GBC/PE), a cement consisting of the same PMMA used in GBC with apatite- and wollastonite-containing glass-ceramic (AW-GC) powder (designated AWC), and AWC with PE (designated AWC/PE). Each filler was added to the cement at 70 wt %. Adding PE to either GBC or AWC resulted in increases in the bending strength and decreases in the Young's modulus compared with the unmodified cements. Cements were packed into the intramedullar canals of rat tibiae to evaluate osteoconductivity as determined by an affinity index. Rats were sacrificed at 4 and 8 weeks after operation. The affinity index (length of bone in direct contact with the cement expressed as a percentage of the total length of the cement surface) was calculated for each cement. Adding PE to either GBC or AWC resulted in significant increases in the affinity index compared with the unmodified cements. The affinity index for GBC was significantly higher than that of AWC, and that for GBC/PE was also significantly higher than that of AWC/PE. The affinity indices for each cement increased significantly with time up to 8 weeks. Our study revealed that the higher osteoconductivity of GBC/PE was due to the large alkyl group in the PE monomer, to the hydrophilicity of the phosphoric acid in the PE monomer, and to the higher bioactivity of the bioactive glass beads at the cement surface. GBC/PE shows promise as an alternative bone cement with improved properties compared with conventional PMMA bone cement.  相似文献   

20.
The goal of the present work was to establish the relative influence of one exogenous variable versus one endogenous variable on the fully-reversed tension-compression fatigue performance of bone cement. The method used to mix the cement constituents was the exogenous variable, while the viscosity of the mixed cement dough was the endogenous variable. Two commercial cement formulations (Palacos R and Osteopal) and two cement mixing methods (hand mixing and vacuum mixing) were used. It was found that for a given mixing method, cement viscosity exerts a marginal influence on fatigue performance. On the other hand, for a given cement formulation, vacuum mixing led to a statistically significant improvement in fatigue performance. The present results demonstrate the superior influence of mixing method over cement viscosity.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号