首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 250 毫秒
1.
俯卧位对全麻机械通气患者呼吸力学参数的影响   总被引:3,自引:0,他引:3  
目的观察俯卧位对全麻机械通气患者呼吸力学参数的影响。方法选择择期手术的骨外科脊柱手术患者24例,ASAⅠ级或Ⅱ级。全麻诱导后经口插加强气管导管,行间歇正压通气模式控制呼吸,潮气量(VT)8~10ml/kg,呼吸频率12次/min,吸呼比1∶2。术前仰卧位通气10min后摆放俯卧位通气10min,经麻醉机采集数据:呼吸末正压(PEEP)、气道峰压(PEAK)、气道平台压(PLAT),翻身前机械通气后以及翻身后1min、5min、10min各取一次数据,结果取其平均值,并分别在翻身前后第10分钟采集动脉血,行血气分析[动脉血氧分压(PaO2)、动脉血二氧化碳分压(PaCO2)],计算胸肺顺应性[CT,静态顺应性(CTST);动态顺应性(CTD)]。结果 PEAK仰卧位时(13.50±2.31)cmH2O,俯卧位时(16.27±2.87)cmH2O;CTST仰卧位时(55.15±11.56)ml/cmH2O,俯卧位时(42.62±8.68)ml/cmH2O;CTD仰卧位时(43.79±8.24)ml/cmH2O,俯卧位时(35.20±6.54)ml/cmH2O,差异有统计学意义(P<0.01)。翻身前后血气分析结果...  相似文献   

2.
目的 :运用高容量低压力囊内压测压表对插管全麻中气管套内压的监测 ,比较经验充气与测压表监测下两组充气量与囊内压的不同。方法 :运用高容量低压力囊内压测压表 ,观察气管插后通过经验充气后的充气量与囊内压 ,以及在压力表的监测下达到最小漏露量时的充气量与囊内压。结果 :经验充气后的充气量男性为 (7.5 8±1.5 3)ml,女性为 (5 .5 4± 1.2 3)ml,囊内压分别为 (5 5 .96± 6 .2 4 )cmH2 O和 (6 8.6 2± 4 .6 5 )cmH2 O。最小漏露量时的充气量男性为 (4.33± 1.71)ml,女性为 (3.18± 1.92 )ml,而囊内压则分别为 (2 2 .2 2± 6 .5 6 )cmH2 O和 (15 .71±4 .6 2 )cmH2 O。最小漏露量时的充气量与囊内压均比经验充气时量小 ,两组相比 ,差异有显著性。结论 :在插管全麻时应常规使用专用高容量低压力表监测下进行气囊充气 ,以减少术后并发症发生的可能性  相似文献   

3.
目的观察Supreme喉罩用于侧卧位腹腔镜手术患者的安全性及可行性。方法择期泌尿外科全麻下侧卧位腹腔镜手术的患者80例,性别不限,年龄2072岁,ASAⅠ或Ⅱ级,MallampatiⅠ或Ⅱ级,随机分为两组(n=40):Supreme喉罩组(S组)和气管插管组(T组)。麻醉前所有患者均口服亚甲蓝胶囊。S组根据患者体重选择喉罩型号,麻醉诱导后置入喉罩,T组在直接喉镜下行气管插管。(1)记录基础值(T1)、插管前(T2)、插管后3 min(T3)、拔管前(T4)、拔管后3 min(T5)的心率(HR)、收缩压(SBP)、舒张压(DBP)、平均动脉压(MAP);(2)记录S组仰卧位和侧卧位喉罩气道密封压,并行纤维支气管镜检查评分,以评价喉罩对位情况;(3)记录术中潮气量(VT)、血氧饱和度(SpO2)、呼气末二氧化碳分压(PETCO2)及气道压变化、喉罩的漏气情况;(4)手术结束时应用纤维支气管镜根据亚甲蓝染色情况判断是否发生反流及误吸;(5)记录拔除气管导管或喉罩后亚甲蓝染色情况及咽部并发症。结果与T组比较,S组喉罩置入后HR、SBP、DBP、MAP明显降低。S组出现反流3例(7.5%),T组出现反流1例(2.5%),差异无统计学意义。两组均未发生误吸。S组拔管时呛咳发生率明显低于T组(P<0.05)。两组套囊血迹、咽喉痛以及声嘶的发生率差异无统计学意义。术中SpO2、PETCO2、气道压均在正常范围内,组间比较差异无统计学意义(P>0.05)。S组喉罩仰卧位气道密封压为(28.1±4.0)cmH2O,明显高于侧卧位(25.6±4.7)cmH2O(P<0.01),S组仰卧位与侧卧位纤维支气管镜评分差异无统计学意义(P>0.05)。结论 Supreme喉罩可安全应用于泌尿外科侧卧位腹腔镜全麻的手术,通气效果满意,气道密封性良好,与气管插管相比不增加反流误吸的发生率,且置入后血流动力学更稳定,拔出后呛咳率低,可安全应用于泌尿外科腹腔镜手术全麻的气道管理。  相似文献   

4.
喉罩作为对插管技术的一种补充设施,是通过气囊(通气罩)充气来密闭腭弓及咽喉,以封闭喉口来保证气道密闭,从而达到有效机械通气的目的[1].充气量不足将导致喉罩漏气;而充气量过大,会造成咽喉部相关并发症,甚至发生喉罩套囊移位.有研究指出,将喉罩囊内压控制在44 mmHg以下可有效减少术后呼吸道的并发症[2].  相似文献   

5.
目的采用随机自身对照设计方法比较食管引流型喉罩通气道(PLMA)和标准型喉罩通气道(SLMA)用于间歇正压通气的有效性。方法选择50例经美国麻醉医师协会(ASA)身体状态分级标准分为1~2级、拟在全身麻醉下实施择期整形外科手术患者。在常规麻醉诱导后,顺序插入PLMA和SLMA,将通气罩内压充气至60cmH2O(1cm H2O=0.098kPa),评价两种喉罩通气道充气前后的肺通气满意度和气道密封压,同时进行光导纤维支气管镜(FOB)评分,确定通气罩的解剖位置。然后将潮气量设定为10ml/kg实施间歇正压通气,记录间歇正压通气后连续5次呼吸的平均呼潮气量和平均吸气峰压。结果在通气罩未充气情况下,插入PLMA后有46例(92%)患者获得了良好和尚可的肺通气效果,而插入SLMA后仅有22例(44%)患者获得了良好和尚可的肺通气效果;PLMA的气道密封压显著高于SLMA(P<0.05)。将通气罩内压充气至60cmH2O,采用PLMA的50例患者均获得良好的肺通气效果,但采用SLMA时仅有28例获得良好的肺通气效果;PLMA所需的充气量和充气后获得的气道密封压均显著高于SLMA(P均<0.05)。采用PLMA时所有患者的气道密封压均高于或等于采用SLMA时;采用PLMA时除2例患者外,其他患者所需的充气量也均高于采用SLMA时。PLMA通气罩位置的FOB评分显著低于SLMA(P<0.05)。采用PLMA维持气道的29例患者和采用SLMA维持气道的21例患者的平均呼潮气量、吸气峰压及维持气道时间差异均无显著性(P均>0.05)。结论与SLMA相比,PLMA可为正压通气提供更好的气道密封压,而且对声门和食管上端具有潜在的隔离作用,用于正压通气时PLMA比SLMA更有效、更安全。  相似文献   

6.
目的 分析手持测压表间断测压法导致气管导管套囊内压力损失的原因,为临床工作中正确使用测压表提供参考。 方法 实验研究,在气管模型中,使用测压表间断测量气管导管套囊内压力,通过控制三通管分别测量断开及连接指示气囊导致的套囊内压力损失值和测压表导致的套囊内压力损失值。 临床研究,选取重症医学科建立人工气道的患者作为研究对象,用手持测压表测量其气管导管套囊内压力。 结果 实验研究和临床研究中测压表间断测量所致的套囊内压力损失值分别为 (10.18±0.52) cmH2O和 (10.27±0.93) cmH2O,两者比较,差异无统计学意义(P>0.05);实验研究显示断开及连接指示气囊导致的套囊内压力损失值为(1.23±0.53) cmH2O,手持测压表导致的套囊内压力损失值为(9.18±0.54) cmH2O。 结论 间断测量过程中造成的套囊内压力损失值约等于测压表导致的压力损失值与断开及连接指示气囊导致的压力损失值之和。  相似文献   

7.
吸痰对人工气道套囊内压力的影响   总被引:2,自引:0,他引:2  
目的 通过观察吸痰时及吸疾后30min人工气道套囊压力的变化,探讨吸痰对人工气道套囊压力的影响.方法 吸痰前用测压表调整人工气道套囊压力为30CMH2O,持续监测吸痰时的套囊最高压力、患者有无咳嗽,以及吸痰后5min、10min、15min、30min的压力,并记录吸痰后套囊压力降至25cmH2O时所需时间.结果 在吸痰过程中81.25%(78/96)患者发生咳嗽.本组套囊内压力平均明显升高至(89.42±31.37)cmH20,咳嗽者套囊内平均压力为(96.00±25.99)cmH2O,高于无咳嗽者套囊内平均压力(60.89±37.14)cmH2O,差异有统计学意义(P<0.01).吸痰时套囊内压力升高者较保持者更易下降至正常低限(25cmH2O),差异有统计学意义(P<0.01).结论 患者吸痰过程中容易发生咳嗽,人工气道套囊内压力波动明显,建议临床上在吸痰后30min内调整套囊内压力,必要时应立即调整,避免囊内压力过低或过高对患者的伤害.  相似文献   

8.
目的:观察proseal型喉罩用于面神经微血管减压术的安全性及效果.方法:32例面肌痉挛需行面神经微血管减压术的患者随机分为proseal型喉罩组和气管插管组,每组16例.两组患者麻醉诱导及维持均按相同的药物、相同的公斤体重剂量.监测呼吸、循环功能、麻醉深度指数.分别于麻醉诱导前(T0)、气管插管或置入喉罩1 min时(T1)、钻颅骨时(T2)、面神经松解时(T3)、呼之能睁眼时(T4)、拔管或取出喉罩1 min 时(T5)测定并记录各监测指标.结果:气管插管组患者插管后心率(98.7±13.4)次/min、平均动脉压(78.3±5.9)mmHg分别较插管前(79.6±12.7)次/min、(68.9±7.5)mmHg组间的差异具有显著性意义(P<0.05):proseal型喉罩组患者潮气量(T5时)(368±37)mL、气道压(T4时)(12.12±2.73)cmH2O、肺顺应性(T4时)(58.34±5.37)mL/cmH2O分别与气管插管组(301±27)mL、(18.45±2.85)cmH2O、(48.44±2.7)mL/cmH2O组间差异有显著性意义(P<0.05);喉罩组患者麻醉深度指教在T4(88.34±5.25)、T5(94.64±7.58)时分别与气管插管组(96.18±5.89)、(75.79±8.25)组间差异有显著性意义(P<0.05).结论:Proseal型喉罩较气管插管可明显降低心血管反应;对于短时间面神经微血管减压术的麻醉,proseal型喉罩较气管插管未明显影响潮气量及呼气末二氧化碳分压,降低患者苏醒期气道压骤然升高,有利于肺顺应性的恢复,是安全的.  相似文献   

9.
目的探讨在腹腔镜胆囊切除手术中安全、有效使用普通喉罩的方法。方法选择腹腔镜胆囊切除手术患者100例,随机均分两组:对照组,喉罩插入后以敷料填塞双侧颈项固定。试验组,诱导期面罩去氮吸氧就开始持续正压通气,观察气道压力并对气道顺应性做评估;喉罩插入后,分别在头颈保持正中后仰位和左、右侧偏转45°时测定气道密封压,并据此选择固定位置。结果对照组,二氧化碳气腹后喉罩通气漏气9例,试验组漏气2例。组间比较有统计学差异(P<0.05)。试验组面罩通气时气道压力维持在814 cmH2O,平均(12.51±1.69)cmH2O,与喉罩插入后[(14.65±2.24)cmH2O](Vt、RR未做调整)比较,有统计学差异(P<0.01)。试验组喉罩插入后气道密封压测定结果:正中后仰位占优势的13例(26%),左或右单侧占优势的12例(24%)。结论去氮吸氧时采用持续正压通气,观测气道压力,对患者肺及气道顺应性重新评估;喉罩插入后测定不同的头颈位置时气道密封压并以此选择最佳位置固定,可以减少气腹后持续正压通气时漏气率。  相似文献   

10.
气管导管套囊不同充气方法的比较   总被引:7,自引:1,他引:6  
目的比较气管导管套囊的不同充气方法,获得理想的套囊充气方法。方法连续观察60例气管插管与气管切开并行机械通气的患者,按随机数字表分为3组,分别给予3种不同的方法给套囊充气:①指感法;②最小封闭压力法;③套囊测压表法。比较不同方法的操作时间、气道漏气发生率及气囊压力。结果套囊测压表组套囊压力控制最理想,为(28.85±2.3)cmH2O,与另两组比较,差异有统计学意义(P0.05)。结论套囊测压表法简便、有效、安全。  相似文献   

11.
目的:比较不同体位对ARDS患者机械通气效果的影响。方法选择2010年1月-2012年12月行机械通气治疗且无俯卧位机械通气禁忌证的ARDS患者40例,采用随机数字表法随机分为俯卧位通气组和仰卧位通气组,每组各20例。比较两组患者机械通气前后生命体征和动脉血气变化,治疗3d后平均气道压、平台压、气道阻力,机械通气时间和急诊科住院时间。结果组内比较,两组患者治疗后T、P、MAP、PaCO2均降低,差异均有统计学意义(P<0.01);PETCO2、pH值、PaO2、PaO2/FiO2均升高,差异均有统计学意义(P<0.01)。组间比较,T、P、PETCO2、MAP、pH值、PaO2、PaCO2差异均无统计学意义(P>0.05);俯卧位通气组患者在俯卧位治疗3 d后PaO2/FiO2为(282±177;22),高于仰卧位通气组治疗3 d后的(245±177;21),差异有统计学意义(t=6.18,P<0.01)。治疗3 d后,俯卧位通气组患者平均气道压、平台压、气道阻力分别为(6.8±177;0.5)cmH2O,(17.1±177;2.0)cmH2O,(14.9±177;1.2)cmH2O/(L±183; s),仰卧位通气组分别为(8.5±177;0.9)cmH2O,(20.6±177;2.3)cmH2O,(21.1±177;0.8)cmH2O/(L±183; s),差异均有统计学意义(t值分别为7.38,5.13,18.83;P<0.01)。俯卧位通气组患者机械通气时间和急诊科住院时间均短于仰卧位通气组,差异均有统计学意义( t值分别为9.007,6.379;P<0.01)。结论俯卧位通气可以更有效地改善氧合指数,纠正低氧血症,同时对患者气道影响较小,是较为理想的通气体位。  相似文献   

12.

Purpose

This single-center, prospective, randomized, double-blind, 2-arm, parallel group comparison trial was performed to establish whether the adult-sized laryngeal mask airway (LMA) Classic (The Laryngeal Mask Company Ltd, Henley-on-Thames, UK) could be used safely without any consideration of cuff hyperinflation when a cuff of the LMA Classic was inflated using half the maximum inflation volume or the resting volume before insertion of device.

Basic procedures

Eighty patients aged 20 to 70 years scheduled for general anesthesia using the LMA Classic were included. Before insertion, the cuff was partially filled with half the maximum inflation volume in the half volume group or the resting volume created by opening the pilot balloon valve to equalize with atmospheric pressure in the resting volume group. Several parameters regarding insertion, intracuff pressure, airway leak pressure, and leakage volume/fraction were collected after LMA insertion.

Major findings

The LMA Classic with a partially inflated cuff was successfully inserted in all enrolled patients. Both groups had the same success rate of 95% at the first insertion attempt. The half volume group had a lower mean intracuff pressure compared with the resting volume group (54.5 ± 16.1 cm H2O vs 61.8 ± 16.1 cm H2O; P = .047). There was no difference in airway leak pressure or leakage volume/fraction between the 2 groups under mechanical ventilation.

Conclusions

The partially inflated cuff method using half the maximum recommended inflation volume or the resting volume is feasible with the adult-sized LMA Classic, resulting in a high success rate of insertion and adequate range of intracuff pressures.  相似文献   

13.
大鼠糖尿病性阴茎勃起功能障碍模型的建立   总被引:1,自引:0,他引:1  
目的探讨链霉佐菌素(STZ)腹腔注射法建立糖尿病(DM)阴茎勃起功能障碍(ED)动物模型的可行性,以便找到一种发病机制与临床接近的疾病模型。方法模型组雄性大鼠,腹腔注射STZ;正常对照组大鼠,腹腔注射枸椽酸钠液。4d后,快速法测定血糖;10周后,分别测定2组大鼠阴茎海绵体内压(ICP)。结果动物模型血糖浓度:实验组(335.8±62.8)mg/dl显著高于对照组(99.4±24.4)mg/dl(p〈0.01)。DM大鼠基础ICP和刺激勃起神经ICP均明显低于正常大鼠(p〈0.01)。结论腹腔注射STZ诱导糖尿病大鼠出现典型的糖尿病临床症状,血糖明显增高,ICP下降,勃起功能明显受损。  相似文献   

14.
目的探讨机械通气气管套囊指标对急性肺损伤兔气管黏膜组织超微结构的影响。方法健康兔90只,按气囊压力不同分为A(气囊压力30cmH2O,气囊充气时间1h、2h、4h、8h)、B(气囊压力20cmH2O,气囊充气时间1h、2h、4h、8h)、C(气囊压力20cmH2O,每隔2h、4h、8h气囊放气10、20、30min)、D(对照组)4组,分别对气管黏膜进行电镜超微结构观察。结果气囊压力20cmH2O维持〈8h,上皮少量纤毛缺失,柱状上皮细胞轻度肿胀,每隔4h放气20min,上皮细胞层次较清晰,细胞形态基本正常。结论气囊压力在20cmH2O对气管黏膜的损伤最轻;气囊充气4h后放气时间≥20min再充气,可减轻气管黏膜损伤。  相似文献   

15.
目的观察传统机械通气和肺保护性机械通气治疗新生儿急性呼吸衰竭的临床情况。方法选择40例急性呼吸衰竭新生儿患儿,随机分为两组,A组用传统机械通气,B组用肺保护性机械通气。A组潮气量(VT)10~12ml/kg,气道峰压(PIP)〈25cmH2O,呼气末正气(PEEP)(5.0±1.5)cmH2O,呼吸频率(RR)60次/min;B组VT为5~8ml/kg,PEEP为(7.6±1.5)cmH2O,RR为40~60次/分。结果转归比较:两组所有病人均治愈。呼吸机参数比较:两组在维持SaO2在90%以上且PaCO2〈8.0kPa的呼吸机各项参数,A组的VT(10.11±1.20)ml/kg、PIP(24.01±2.10)cmH2O、PEEP(7.50±1.50)cmH2O,两组VT、PIP差异有非常显著性(P〈0.01),两组PEEP的差异无显著性(P〉0.05)。血气比较:pH值A组7.35±0.10,B组7.25±0.15;PaCO2为A组(6.90±0.72)kPa,B组(93.0±2.8)kPa;两组pH、PaCO2、SaCO2(%)值比较差异均无显著性(P均〉0.05)。两组并发症比较:A组肺损伤4例,循环系统并发症3例,B组无。结论传统策略和肺保护性策略通气均能治愈新生儿急性呼吸衰竭,但后者并发症较少。在维持PH、PaCO2、PaO2、SaO2基本相同的情况下,肺保护性通气的呼吸机参数VT和PIP较传统通气明显降低。  相似文献   

16.
BACKGROUND:Adequate airway management plays an important role in high-quality cardiopulmonary resuscitation(CPR).Airway management is usually performed using an endotracheal tube(ETT)during CPR.However,no study has assessed the effect of ETT size on the fl ow rate and airway pressure during CPR.METHODS:We measured changes in peak inspiratory fl ow rate(PIFR),peak airway pressure(Ppeak),and mean airway pressure(Pmean)according to changes in ETT size(internal diameter 6.0,7.0,and 8.0 mm)and with or without CPR.A tidal volume of 500 mL was supplied at a rate of 10 times per minute using a mechanical ventilator.Chest compressions were maintained at a constant compression depth and speed using a mechanical chest compression device(LUCAS2,mode:active continuous,chest compression rate:102±2/minute,chest compression depth 2–2.5 inches).RESULTS:The median of several respiratory physiological parameters during CPR was significantly different according to the diameter of each ETT(6.0 vs.8.0 mm):PIFR(32.1 L/min[30.5–35.3]vs.28.9 L/min[27.5–30.8],P<0.001),Ppeak(48.84 cmH2O[27.46–52.11]vs.27.45 cmH2O[22.53–52.57],P<0.001),and Pmean(18.34 cmH2O[14.61–21.66]vs.13.66 cmH2O[8.41–19.24],P<0.001).CONCLUSION:The changes in PIFR,Ppeak,and Pmean were related to the internal diameter of ETT,and these values tended to decrease with an increase in ETT size.Higher airway pressures were measured in the CPR group than in the no CPR group.  相似文献   

17.
目的:研究俯卧位鼻塞持续气道正压通气对早产儿呼吸暂停的影响。方法选择NICU收治的鼻塞持续气道正压通气的早产儿80例,按随机数字表法分为俯卧组和仰卧组各40例,两组均予经鼻持续气道正压通气( NCPAP)和氨茶碱治疗以及相关护理,比较两组治疗效果。结果俯卧组在治疗早产儿呼吸暂停中总有效率为97.5%,仰卧组82.5%,两组比较差异有统计学意义(χ2=8.41 ;P<0.01)±俯卧组的PaO2和PaO2/FiO2分别为(77.24±9.56),(171.25±31.13)mmHg,均高于仰卧组的(67.52±8.61),(143.26±26.34)mmHg,差异有统计学意义(t分别为2.16,2.14;P<0.05)±俯卧组的上机时间、住院时间、氨茶碱使用时间分别为(3.65±2.01),(28.25±3.98),(10.82±9.08)d;均低于仰卧组的(4.83±3.51),(30.14±12.61),(12.2±9.37)d,差异有统计学意义(t分别为0.23,1.96,2.37;P<0.05)。结论鼻塞持续气道正压通气早产儿采取俯卧位时,可改善氧合、提高PaO2和氧合指数,并可减少呼吸暂停的发生,缩短上机和使用氨茶碱时间,减少气管插管机械通气的需要,减少住院时间,减少住院费用,减轻家长的经济负担。  相似文献   

18.
目的 评价环状软骨压迫(CP)对食管引流型喉罩通气道(PLMA)插入操作和正压通气功能的影响.方法 50例按美国麻醉医师协会(ASA)标准身体状态分级为Ⅰ级的择期整形外科手术患者被纳入研究.静脉麻醉诱导后,于CP下插入PLMA,保留专用引导器并将通气罩内压充气至60 cm H2O(1 cm H2O=0.098 kPa).观察肺通气满意度,测定气道密封压,并采用光导纤维支气管镜(FOB)评价通气罩的解剖位置.暂时终止CP,采用专用引导器进一步推送PLMA到达理想位置,并重新调整通气罩内压至60 cm H2O.再次评价上述指标,并记录CP下和非CP下正压通气时的呼潮气量和吸气峰压,观察经PLMA插入胃管的情况并评价引流管解剖位置的FOB评分.结果 与在CP下插入PLMA比较,在临时解除CP并进一步推送PLMA后,肺通气满意度(良好和尚可为50例比14例)、气道密封压[(27±7)cm H2O比(21±7)cm H2O]和通气罩解剖位置的FOB评分均显著改善(P均<0.05).在将PLMA推送至理想位置后,虽然在CP和非CP时的正压通气呼潮气量差异无显著性,但CP时的吸气峰压[(28±5)cm H2O]却显著高于非CP时[(14±2)cm H2O,P<0.05].结论 CP可阻碍将PLMA插入到理想位置,在暂时终止CP的情况下,采用专用引导器可将PLMA插入到理想位置,而且CP可显著增加正压通气的吸气峰压.  相似文献   

19.
韩玉  代庆春  沈洪丽  苗晓云  回志  张晓卫 《临床荟萃》2012,27(20):1772-1775
目的 观察肺复张对肺外源性急性呼吸窘迫综合征(ARDS)患者氧合指数[氧分压(PaO2)/吸入氧气浓度(FiO2)]、呼吸力学及血流动力学的影响.方法 14例肺外源性ARDS患者行保护性肺通气,稳定后开始肺复张治疗.实施控制性肺膨胀(SI)进行肺复张,每8小时进行1次,共3天,纪录每天第1次患者治疗前及治疗后1小时的血气指标、呼吸机参数及肺复张前后的血流动力学指标.结果 1、2、3天肺复张治疗后1小时患者PaO2/FiO2较治疗前均有上升,(162.6±19.80)mmHg vs(220.93±34.10)mmHg,(195.6±24.40) mmHg vs (243.3±34.60)mmHg,(222.57±27.40) mmHg vs(254.71±38.90)mmHg(P<0.05或<0.0l);气道峰压[PIP:(35.64±2.71)cmH2O vs(34.07±2.58)cmH2O,(32.86±3.30)cmH2O vs(30.93±3.15)cmH2O,(30.14±2.66)cmH2O vs (28.07±3.27)cmH2O,P<0.01]、气道平台压[Pplat:(31.29±2.49)cmH2O vs (28.93±2.63) cmH2O,(28.79±3.02) cmH2O vs(26.86±3.13)cmH2O,(25.71±2.09)cmH2O vs(23.57±2.34)cmH2O,P<0.01]在肺复张治疗后均下降,呼吸系统静态顺应性(Cst)在肺复张治疗后改善,且整体呈升高趋势[(26.21±3.26)ml/cmH2O vs (30.14±3.70) ml/cmH2O,(29.36±4.25) ml/cmH2O vs (33.64±5.30) ml/cmH2O,(32.14±5.05) ml/cmH2O vs (35.57±5.57)ml/cmH2O,P<0.01)];14例患者中有9例在肺复张过程中心率升高、血压下降,但均能于复张后3分钟恢复至复张前水平,余患者肺复张过程中心率、血压未见明显波动,14例患者均无心律失常发生.结论 对于肺外源性ARDS,肺复张可明显改善氧合,改善呼吸系统顺应性,对血流动力学影响轻徽.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号